Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Taking down cement plaster on wall, ceiling, chajjas, roof projections, lintel, etc of any description including raking out joints, hacking for key and scrubbing down with water etc and disposing off the rubbish materials out side MD land complete all as specified and directed. |
| 2 | M&L for 20 mm thick rendering in cement mortar (1:4) on fair faces of brick work in two layers (10mm & 10mm) mixed with water proofing compound in top layer 200 ml per beg of cement or as per manufacturer's instructions finishing the surface fair and even without using extra cement complete all as specified and directed. Note: Water proofing compound shall be measured and paid seperately under relevant item of schedule 'A'. |
| 3 | Supply only liquid water proofing compound conforming to IS: 2645 - 1975 specification complete all as specified and directed. |
| 4 | M&L for 15mm thick rendering in cement mortar 1:6 on fair face/other than fair face of brick work or concrete surface finished fair and even (without using extra cement) complete all as specified and directed. |
| 5 | M&L for rendering 5mm thick in cement mortar 1:3 on ceiling, soffits of slabs, chajjas, columns and beams etc and finished the plastered surface even and smooth without using extra cement complete all as specified and directed. |
| 6 | M&L for preparing new Plastered surfaces of walls and applying two coats acrylic-based distemper of shade as approved by GE over a coat of primer over a coat of putty (average 1.5mm thick) on surfaces of wall as per the manufacturer's instructions complete all as specified and directed. Note: Application of new finishes to be carried out mechanically by authorised applicator and as per the manufacturer's instructions. |
| 7 | M&L for complete removal of existing treatment of old plastered surfaces of walls and applying two coats acrylic based distemper of shade as approved by GE over a coat of primer over a coat of putty (average 1.50mm thick) on surfaces of wall including preparation as per the manufacturer's instructions complete all as specified and directed. Note: Application of new finishes to be carried out mechanically by authorised applicator and as per the manufacturer's instructions. |
| 8 | M&L for preparing new Plastered surfaces of walls and finishing the walls with Acrylic smooth exterior anti-fungal paint of required shade as approved by GE : New work (Two coats applied @1.67 Ltr/10 Sqm over and including priming coat of exterior primer applied @ 2.20 Kg/ 10 sqm) over and incl a coat of putty (average 1.50mm thick) complete all as specified and directed. |
| 9 | M&L for complete removal of existing treatment of old plastered surfaces of walls and finishing the walls with Acrylic smooth exterior anti-fungal paint of required shade as approved by GE : New work (Two coats applied @1.67 Ltr/10 Sqm over and including priming coat of exterior primer applied @ 2.20 Kg/ 10 sqm) over and incl a coat of putty (average 1.50mm thick) including preparation complete all as specified and directed. |
| 10 | M&L for preparing newly plastered or unplastered surface of ceiling and applying three coats of white washing complete all as specified and directed. |
| 11 | M&L for preparartion of old surfaces of ceiling & applying two coat of white washing complete all as specified and directed. |
| 12 | Demolition of brick work built in cement mortar of any description complete all as specified and directed. |
| 13 | M&L for brickwork with flyash old size bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 complete all as specified and directed. |
| 14 | M&L for brickwork with fly ash old size bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed. |
| 15 | Dismantling floor, hearth or wall tiling including cement mortar bedding (including backing), removing serviceable tiles and rubbish off the premises complete all as specified and directed |
| 16 | M&L for non - skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tile, laid over and including 15 mm thick screed bed or bedding layer of cement mortar in (1:6) for laying floor finishes complete all as specified and directed. |
| 17 | M&L for joint free non - skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tile, laid over and including 15 mm thick screed bed or bedding layer of cement mortar in (1:6) for laying floor finishes complete all as specified and directed. |
| 18 | M&L for joint free non - skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, on vertical surfaces such as skirtings, dados and risers to steps etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tile, complete all as specified and directed. |
| 19 | M&L for 10 mm thick rendering/ backing coat in CM (1:3) as in vertical surfaces of skirting, dados etc complete all as specified and directed. |
| 20 | M&L for glazed ceramic coloured tiles/ digital elevation tiles of size 300 X 450 X 7-8 mm/300 X 600 X 7-8 mm thick as on vertical surfaces of wall such as skirting, dado, riser etc. in Bath, WC and Kitchen set and jointed in neat cement slurry and pointed in with tile grout of approved make to match the surface of tile as approved by Engr-in-Charge complete all as specified and directed. |
| 21 | M&L for machine cut kota stone slab flooring 18-20mm thick laid over 20mm thick cement screed base in CM (1:6) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete, including rounding the exposed edges of kota stone complete all as specified and directed. |
| 22 | All as per item No 21 here in before but as in skirting ( 12 to 15 mm thick) but on 15 mm thick rendering/ backing coat in CM (1:3) complete all as specified and directed. |
| 23 | M&L for 18 to 20 mm thick granite (of any type) work (table rubbed and polished) in steps, Jambs, pillars, window cills, cooking platforms, corner shelf, Flat shelf and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, laid over and including 15 mm thick cement plaster (1:4) including rounding the exposed edges of granite complete all as specified and directed. |
| 24 | All as per item No 23 here in before but as in skirting ( 12 to 15 mm thick) but on 10 mm thick rendering/ backing coat in CM (1:3) complete all as specified and directed. |
| 25 | Taking down tarfelt with cement plaster from roof surfaces and lowering and removing the same to a distance exc. 50m and n. exc. 100m incl roughening of old concrete suirface of roof by wire brushing and cleaning the surface to remove all loose dust etc complete all as specified and directed. |
| 26 | M&L for water proofing treatment to RCC roof slab including parapet comprising of the following course of tretment/specified from bottom to top (a) Applying Bituminous primer @ 0.40 Ltr per Sqm over plastered surface of roof including parpet surfaces. Bitumnious primer shall be 'Tar Mastic' manufactured by M/S STP LTD or 'EMW FLATE; manufactured by M/S Texsa India Ltd. (b) Over the priming coat laying one layer APP based polymeric membrane with non woven polyster fabric weight not less than 160 gms per sqm. Polymeric membrane shall be taken to a height of 60cm (mim) and than inserted th groove of perafit wall and shall be finished a membrance flashing (c) Application of two coats of Bituminous aluminum paints over the polymeric memnrance after necessary preparation and cleaning, Thickness 3mm.Note :- Laying APP based polymeric membranceshall be done by tourch on mathod or as per manufacture insturction. (ii) A minimum overlap of 100 mm shall be maid at the end 75mm shall be maid at the side and sealed overlaped and joint as per manufacture instructions. Make :- \\"SUPER THERMOLAY\\" manufacturer by STP Ltd of MOPLY FP manufacture by Texsa India Ltd. |
| 27 | M&L for 10mm thick screedd bed or bedding layeres in cement mirter (1:4) in order to maintain proper slope over existing roof surface for applying single component acrylic polymner modified, fininshed even and smooth without using extra cement mixed with water proofing compound complete all specified and as directed. Note :- Polymeric membrane and WPC shall be measured and paid spearately under relevant items of this Sch 'A'. |
| 28 | M&L for 25mm thick PCC 1:2:4 type B0 (Using 12.5 mm graded stone aggregate) mixed with water proofing compound and laid on RCC slab as base layer for roof tratment rufning the topo surface of concrete by using broom stick while the cocrete is green complete all as specified. Note:- WPC paid separatly under relivant items. |
| 29 | S&F Powder coated aluminium louvered ventilators of size n exc 0.50 Sqm area with glass louvers, without sash bars of aluminium sections weighing not less than 0.605kg/m for frame of size 40x20x2mm including necessary jointing cleats, glazing cleats, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings and 5.5mm thick tinted glass fixed in panels with suitable locking arrangements including taking down of old existing steel ventilator with guard bars and making good disturbed surfaces of wall complete all as specified and directed. |
| 30 | S&F Framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walkways; railings; frame work of water tanks and similar work conforming to Fe290,Gde-E-165 complete all as specified and and directed. |
| 31 | M&L for preparation of new of previously untreated steel and Iron surface of any description, not otherwise described over 10 cm width or girth and applying two coats of Synthetic enamel paint over one coat of red oxide primer complete all as specified and directed. |
| 32 | Taking down chowkhats or frames with shutters (without taking off shutters from the frame) area exc 1.5 sqm but n exc 4 sqm each and removal from site including cutting holes for taking out hold fast or dismantling brick work/ stone work (holes cut and any other damage to jambs walls for taking out hold fast shall be finished identical to existing finish without extra cost to the Govt) complete all as specified. |
| 33 | S&F pressed steel frames of size 125x60 mm made out with 1.25mm thick MS sheet for doors with one or more rebates including supply and fixing necessary lugs, hinges, lock strike plate, etc. including one soap coat of priming complete all as specified and directed.Note:- The sizes/dimensions and type (profile) of frames shall be as shown in I.S. |
| 34 | S&F pressed steel frames of size 105x60 mm made out with 1.25mm thick MS sheet for doors with one or more rebates including supply and fixing necessary lugs, hinges, lock strike plate, etc. including one soap coat of priming complete all as specified and directed.Note:- The sizes/dimensions and type (profile) of frames shall be as shown in I.S. |
| 35 | S&F 30 mm thick flush shutter, solid core construction, with block board core and plywood face panel, commercial type on both side etc complete all as specified and directed. |
| 36 | S&F second class hardwood, factory made glazed and skelton shutters 35 mm thick open rebated and prepared to receive glass, gauge etc (without sash bars), edges of framing plain chamfered or rounded, fitted with cut and mitred beads for securing glass etc sizes of members of shutters as specified in SSR Part-I Section8, Clause 8.20 (a) supplied and fitted to chowkats. |
| 37 | Taking down chowkhats or frames with shutters (without taking off shutters from the frame) area n.exc 1.5 sqm each and removal from site including cutting holes for taking out hold fast or dismantling brick work/ stone work (holes cut and any other damage to jambs walls for taking out hold fast shall be finished identical to existing finish without extra cost to the Govt) complete all as specified. |
| 38 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing on SI page No 156 of SSR Part-II completed. |
| 39 | S&F Solid PVC door frame of size 50mm X 47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube, supplying and fixing in opening as per specification and drawing on SI page No.160 of SSR Part-II completed complete all as specified and directed. |
| 40 | M&L for preparation of new wooden surfaces of any description not other wise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 41 | M&L for providing plain cement concrete type C-1, 1:3:6, (using 20 mm graded stone aggregate), as in copings, bed block for filing hollow space of steel chowkhats, fixing of hold fast, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed. |
| 42 | S&F 100 mm butt hinges stainless steel complete all as specified and directed. |
| 43 | S&F 140 mm Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed. |
| 44 | S&F aluminium anodised barrel tower bolts of extruded section 200 mm long complete all as specified and directed. |
| 45 | S&F aluminium handles 150mm size cast type anodised complete all as specified and directed. |
| 46 | S&F 300 mm long mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all specified and directed. |
| 47 | S&F 150 mm long Aluminium anodised barrel tower bolts complete all as specified and directed. |
| 48 | S&F aluminium handles 125 mm size cast type anodised complete all as specified and directed. |
| 49 | S&F in repair stainless steel curtain rod of 25 mm dia and thickness not less than 0.75 mm fixed with curtain rod holder and finials etc. complete all as specified and directed. |
| 50 | Use and waste of formwork to sides and soffits of, shelves, platform etc rough finished surfeces of concrete flat etc complete all as specified and directed. |
| 51 | M&L for TMT bar 10 mm dia and over cut to length, bent to shape required and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 52 | Use and waste of formwork edge of concrete flats, treads breaks in floors, window cill, concrete railing openings in concrete walls floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and directed. |
| 53 | M&L for RCC nominal mix type A1 1:1.5:3 using 20mm gradded stone aggregate Slabs supported on walls, beams and columns in floors, shelves, platform, lintel, deck slabs and the like complete all as specified and directed. |
| 54 | Demolition of cement concrete (un-reinforced) any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 55 | M&L for PCC 1:2:4 type B-0 (using 12.5mm graded agg) 25 mm thick (average) stone aggregate as in sub base, levelling course to receive floor topping complete all as specified and directed. |
| 56 | M&L for 75mm thick PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate) as in plinth protection, finishing cement concrete surface even & fair without using extra cement including filiing the joints with bitumen & sand in 2:1 proportion etc complete all as specified and directed. |
| 57 | M&L for PCC (1:3:6) type C-1 (using 20mm graded crushed stone aggregate) as in surface channel or drain including use of necessary from work for fair finished surface complete all as specified and directed. |
| 58 | Taking up or down GI 15mm bore pipe and connection including cleaning for refixing or removal from site complete all as specified and directed. |
| 59 | Taking up or down GI 20mm steel tubing and connections incl cleaning for refixing or removal form site complete all as specified and directed. |
| 60 | Taking up or down GI 25 or 32 mm steel tubing and connections incl cleaning for refixing or removal form site complete all as specified and directed. |
| 61 | S&F 15mm bore pipe medium grade galvanised iron water tube concealed (including cutting chasing and making good) with all fittings laid in floors/ fixed to wall etc complete all as specified and directed. |
| 62 | Refixing old 15mm GI tubing and connections concealed in new or old position (including cutting chasing and making good) (walls, ceilling, floor etc) complete all as specified and directed.Note:- Serviceable GI tube Retrieved from above item No 58 shall be used under this item. |
| 63 | S&F 20mm bore pipe medium grade galvanised iron water tube with all fittings laid in floors fixed to wall etc complete all as specified and directed. |
| 64 | Refixing old 20mm GI tubing and connections in new or old position (walls, ceilling, floor etc) complete all as specified and directed.Note:- Serviceable GI tube Retrieved from above item No 59 will be used under this item. |
| 65 | S&F 32mm bore pipe medium grade galvanised iron water tube with all fittings laid in floors fixed to wall etc complete all as specified and directed. |
| 66 | Refixing old 32mm GI tubing and connections in new or old position (walls, ceilling, floor etc) complete all as specified and directed.Note:- Serviceable GI tube Retrieved from above item No 60 will be used under this item. |
| 67 | S&F in repairs vitreous china wash basin, white, flat back, size 550x400mm including cutting for and pinning in ends of brackets or erecting stand inclusive of brackets, CP waste coupling, waste pipe complete all as specified and directed. |
| 68 | S&F in repairs beveled edge mirror of size 600 x 450 mm, mounted on 6 mm thick AC plain building board or PVC board and fixed to wall on wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 69 | S&F in repair 10 ltr capacity dual type PVC flushing cistern low level white colour including PVC connection, PVC flush pipe of required length complete all as specified and directed. |
| 70 | S&F in repair vitreous china squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests with suitable size PVC 'P' or 'S' trap including provision of cement concrete bedding complete all as specified and directed. |
| 71 | S&F in repairs Bib taps fancy type, brass chromium plated for 15mm bore pipe, screwed for iron pipes or for brass ferrule complete all as specified and dierected. |
| 72 | S&F in repairs stop valves fancy type, brass chromium plated with long shank and cup (concealed type) for 15mm bore pipe, screwed both ends including necessary fittings such as sockets for pipe or for union complete all as specified and dierected. |
| 73 | S&F for corner glass shelf 225x 225mm with CP steel frame complete all as specified and directed, complete all as specified and directed. |
| 74 | S&F 15mm bore PVC Connection with PTMT nut of length 600 mm complete all as specified and directed. |
| 75 | S&F in repairs braided Stainless Steel 450mm long Connection Pipe Hose CP For Wash Basin, Kitchen Sink, Geyser complete all as specified and directed. |
| 76 | S&F fancy type swan neck pillar taps, brass with capston heads, chromium plated, screwed down high pressure, with or without lettered hot or cold with long screwed shanks and fly-nuts, screwed for iron pipe 15mm bore complete all as specified and directed. |
| 77 | S&F in repair 15 mm bore angle cock CP with flage complete all as specified and directed. |
| 78 | S&F brass chromium plated tubular towel rail, 20mm dia and 0.80mm thick, D type, 60cm long between flanges complete all as specified and directed. |
| 79 | S&F in repair swivel shower of brass CP with shower arm 125 mm long for fixing with 15 mm bore GI pipe complete all as specified and directed |
| 80 | S&F in repair for 75 mm bore PVC (SWR) floor trap, plain with CP grating (with or without hole) including jointing with solvent cement complete all as specified and directed. |
| 81 | Taking down CI/PVC/AC soil pipe including fittings from wall, treches of any description complete all as specified and directed. |
| 82 | S&F 110mm bore PVC (SWR) pipes, type 'A', single socketed confirming to IS- 13592:1992) in any length with rubber ring joints laid in trenches or in floor complete all as specified and directed. |
| 83 | S&F 110mm bore PVC (SWR) pipes, type 'A', single socketed confirming to IS- 13592:1992) in any length with rubber ring joints fixed to wall complete all as specified and directed. |
| 84 | S&F 110mm bore PVC bends of any radius complete all as specified and directed. |
| 85 | S&F 110mm bore PVC (SWR) branch piece double (double 'Y') equal or unequal complete all as specified and directed. |
| 86 | S&F 110mm bore PVC (SWR) junction double (double 'T') equal or unequal complete all as specified and directed. |
| 87 | S&F 110mm bore PVC SWR vent cowl complete all as specified and directed. |
| 88 | S&F 75mm bore PVC (SWR) pipes, type 'A', single socketed confirming to IS- 13592:1992) in any length with rubber ring joints laid in trenches or in floor complete all as specified and directed. |
| 89 | S&F 75mm bore PVC (SWR) pipes, type 'A', single socketed confirming to IS- 13592:1992) in any length with rubber ring joints fixed to wall complete all as specified and directed. |
| 90 | S&F 75 mm bore PVC (SWR) bends of any radius with acess door complete all as specified and directed. |
| 91 | S&F 75 mm bore PVC (SWR) junction single (Single `T') equal or unequal complete all as specified and directed. |
| 92 | S&F 75 mm bore PVC (SWR) branch piece single (Single `Y') equal or unequal complete all as specified and directed. |
| 93 | S& in repair vitreous China Urinal, Half stall type, white (including flush pipe and waste pipe) complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe complete all as specified and directed. |
| 94 | S&F urinal spreader of CP brass for fixing with 15 mm dia pipe complete all as specified and directed. |
| 95 | S&F 1000 ltrs capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with polythene foam insulation as intermediate layer and closed top) double layer ISI marked (IS: 12701 : 1996), hoisted and fixed in position all as specified in SSR Part I including inlet, outlet and over flow connections etc including dismantling existing tank complete as specified and directed. |
| 96 | S&F 20 mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & highdensity plastic ball screwed for iron pipe and fixed as required to use reducer and check nut complete as specified and directed. |
| 97 | S&F in repair 20mm bore Gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and dierected. |
| 98 | M&L for Endura tiles of size 300 x 300 x 10 mm set, jointed and pointed in neat cement slurry over in pavement / footpath / floors complete all as specified and as directed. |
| 99 | M&L for 15 mm thick screed bed or bedding layer in CM (1:6) complete all as specified and as directed. |
| 100 | M&L for 75 mm thick cement concrete (1:3:6) type C-2 (using 40 mm graded crushed stone aggregate) as in path /steps laid with and incl use and waste of form work and finishing the surface even and rough to receive the topping layer or tiling complete all as specified. |
| 101 | M&L for cement concrete (1:3:6) type C-1 (using 20 mm graded crushed stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified. |
| 102 | Removing building materials and debris (other than excavated earth) to a distance of 5 KM inside MD Land at locations specified including loading and dumping/ leveling at the destination complete all as specified and directed. |
| 103 | M&L for preparation of old wooden surface of any description over 10cm width or girth and applying one coats of synthetic enamel paint complete all as specified and directed. |
| 104 | M&L for preparation of old steel surfaces of any description over 10cm width or girth and applying one coats of synthetic enamel paint complete all as specified and directed. |
| 105 | M&L for hardcore broken stone or boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface |
| 106 | Taking down shutters of any description area exc 1 Sqm and n. exc 2 Sqm each and removal from site complete all as specified |
| 107 | Taking down shutters of any description and refixing in the same opening after resecuring or easing & adjusting area exc 1 Sqm and n. exc 2 Sqm each complete all as specified |
| 108 | M&L for second class hard wood plain solid straight chowkats and frames wrought framed rebated on the solid rounded on chamfered put together with glue pinned and joints. |
| 109 | Supply and fixed in repairs sinks without drainage board made of stainless steel (SS 304 grade) 1mm thick sheet plugs, washers and waste pipe, including a pair of cantilever brackets embedded in wall with suitable size of PCC (1:3:6) type C-1 blocks and connecting union to pipe of overall size 510mm x 430mm bowl size 430mm x 380mm x 203mm all complete as specified and as directed. |
| 110 | S&F factory made steel windows with side hung shutters openable type including friction/projected type hinges steel handle and peg stay complete without glazing bars fixed to existing opening and making to match as per existing surfaces including taking down old windows and cutting holes for taking out hold fast or dismantling brick work/ stone work (holes cut and any other damage to jambs walls for for taking out hold fast shall be finished identical to existing finish without extra cost to the Govt) . |
| 111 | S&F factory made steel windows with side hung shutters openable type including friction/box type hinges steel handle and peg stay complete with glazing bars fixed to existing opening and making good to match as per existing surfaces cutting holes for taking out hold fast or dismantling brick work/ stone work (holes cut and any other damage to jambs walls for for taking out hold fast shall be finished identical to existing finish without extra cost to the Govt). |
| 112 | S&F 3mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sqm in each pane including steel pin. |
| 113 | S&F galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.00mm and fixed with tinned tacks, or galvanised wire staples |
| 114 | Dismantling stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar complete all as specified and directed. |
| 115 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 116 | Demolition of cement concrete (un-reinforced) in ground floor and paving not exc. 15 cm thick (Below or above ground level) complete all as specified and directed. |
| 117 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc for taking credit ( credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed. |
| 118 | M&L for point wiring complete with 1.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LS cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit not less that 20mm dia and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LS (ISI marked) as earth continuity conductor connected to common earth dolly, fabricated sundn terminal box made out of GI sheet steel not less than 1.22 mm thick for boxes upto a size of 200 x 300mm and above this size not less than 1.63 mm thick duly painted with aluminum inside and anticorrosive paint outside, concealed in walls, with 3mm thick bakelite/plastic laminated sheet top cover fixed with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed including cutting chases of existing wall for conduits and sinking for boxes and making good to the disturbed surface of wall/floor and matching with existing specifications. Connections of cable with MCBs or bus bar shall be done through proper size copper/brass thimbles. Where concealing of conduit is not feasible ie on surface of roof etc, conduit shall be fixed on surface with necessary saddles at no extra cost all as specified and as directed for the following :- |
| 119 | One light point controlled by one way switch 5/6 amps. |
| 120 | One ceiling fan/Exhaut fan point controlled by one way switch 5/6 amps. |
| 121 | One socket out let 5/6 amps point on the independent board |
| 122 | One socket out let 5/6 amps point on the same board |
| 123 | All as per item No 118 above but wiring with 2.5 sq mm single core copper conductor for one socket out let 15/16 amps point on the independent board complete all as specified and directed. |
| 124 | S&F switch piano flush type 5/6 amps single pole one way complete all as specified and directed. |
| 125 | S&F socket 2 in 1, 5 Pin, 5/6 amps, white ivory finish flash type complete all as specified and directed. |
| 126 | S&F socket outlet 2 in 1, 5 Pin, 5/15 amp, multipurpose 230 volt flash type complete all as specified and directed by Engr-in-Charge. |
| 127 | S&F switch piano flush type 15/16 amps single pole one way complete all as specified and directed. |
| 128 | S & F deluxe fan electronic regulator 120/180 volts AC 50 Hzs rotary step white/ivory finish complete all as specified. |
| 129 | S&F Ceiling rose, surface type with back plate, three terminal /PVC/ polycarbonate, isolated body complete all as specified and directed. |
| 130 | S & Flamp holder, isolated body, with back plate suitable for batten/angle fittings complete all as specified and directed. |
| 131 | S & F Wall monted slim LED inverter batten 20W 4' long,min output 120 Lumen/watt PF>0.95,surge protection,> 4KV, THD:<10% with PC housing, with integrated LED driver complete all as specified and directed by Engr-in- charge Make HPL Product code HPLLEDINVT5BPC20CW |
| 132 | S & F LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size |
| 133 | S&F Sheet metal enclosure for 12 way Distribution Boards (DB’s), double door, single pole & neutral with 200 amps rated bus bar, IP-20 protection suitable for fixing MCB\\"S/lsolators complete including taking down the old one complete all as specified and directed by Engr-in-Charge. |
| 134 | S&F MCB, Single pole & neutral 40 amps, 240 volts, ‘C’ curve, 10 KA all complete including taking down the old one complete all as specified and directed by Engr-in-Charge. |
| 135 | S&F MCB, Single pole, 6 to 32 amps, 240 volts, ‘C’ curve, 10 KA all complete including taking down the old one complete all as specified and directed by Engr-in-Charge. |
| 136 | M &L for Earthing complete with GI earth plate electrode 600x600x6mm thick buried directly in ground (Earth pit not less than 2.25M deep below normal ground level) with top edge of the plate not less than 1.5m below normal GL. Connected to galvanized earth lead wire 4mm dia by means of nut, bolt, check nut and washers including necessary excavation and earth work in soft/loose soil, GI protection pipe light grade 15mm bore for protecting the GI wire mesh funnel alternate layer of charcoal dust, and salt PCC pit 1:3:6 type C1 using 20mm graded stone aggregate and 50mm thick RCC 1:2:4 type BO using 20mm graded stone aggregate cover re-inforced with 8 mm dia MS TMT bars 80mm C/C both ways complete all as specified and shown in Electrical plate No.3 SSR part-1 and connected to the earth point and testing complete including taking out the old one complete all as specified and directed by Engr-in-Charge. |
| 137 | Taking down Unserviciable ceiling fan , sealing cable end, dismantling blades and removing fan and blades deposite to store for further BER complete all as specified. |
| 138 | S&F ceiling fan complete with blades,down rods and accessories including provision of hook for hanging ceiling fan, 230 V, 1200 mm sweep. BEE star rated with Brushless direct current (BLDC) motor complete all as specified by Engr in charge. |
| 139 | S&F Exhaust fan,heavy duty turbo Jet steel body AC single Phase. 230V of size 450mm sweep, speed1400 RPM with blades,frame and louvers complete with making hole in wall and fixing accordingly all as specified and as directed by Engr-In-Charge. |
| 140 | Excavation in trenches n .exc 1.5 mtr wide and not exec 1.5 mtr depth and getting out in looses/soft soil complete all as specified |
| 141 | Returning, filling, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in any type of soil, complete all as specified and directed. |
| 142 | Removal of excavated material to a distance not exc.50 m and depositing where directed at a level not exceeding 1.5 mtr above starting point. |
| 143 | Supply and laying in Trenches GI water Tubing medium grade of 25 mm dia including all fittings such as sockets, bends, elbows, Union etc . Complete all as specified and as directed by Engr-in-Charge. |
| 144 | M&L for Stop valves 25mm bore, cast copper alloy,screwed down,high pressure,with crutch or butterfly handle,screwed bothends for iron pipe or for unions and fixed. |
| 145 | Cutting of Existing GI pipe of dia 25/50 mm and inserting of Tee in exsisting pipe for connecting new pipe complete all as pecified and as directed by Engr in Charge. |
| 146 | Excavation in trenches n .exc 1.5 mtr wide and not exec 1.5 mtr depth and getting out in looses/soft soil complete all as specified |
| 147 | Returning, filling, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in any type of soil, complete all as specified and directed. |
| 148 | Removal of excavated material to a distance not exc.50 m and depositing where directed at a level not exceeding 1.5 mtr above starting point. |
| 149 | Supply and laying for brick protection for protection of cable over sand cushioning cables inside the trench by using common brunt clay building bricks sub-class “B” old size brick and flat and width wise along the axis of the trench complete all as specified and directed by Engr-in-Charge. |
| 150 | M&L for sand cushioning in cable trenches over & under the cable, with river washed coarse sand, as per standard practice with proper compaction complete all as specified and directed by Engr-in-Charge. (Punned thickness 18 cm shall be considered for payment as per para 19.75 of SSR Part-I) |
| 151 | Supply laying & testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts, (Earthed), grade cross sectional area 16 sq. mm,2 core. |
| 152 | M & L for laying of GI pipe light grade across road for cable protection complete of size 40mm complete all as directed. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail