| Sl. No. | Item Description |
| 1 | Taking down chowkat or frame with shutter (without taking off shutter from the frame) not exceeding 1.50 Sqm each including taking out hold fast embedded in PCC, complete all as specified and directed. |
| 2 | Taking down chowkat or frame with shutter (without taking off shutter from the frame) exceeding 1.5 Sqm and n.exc 4 Sqm each including taking out hold fast embedded in PCC, complete all as specified and directed. |
| 3 | S&F pressed steel frame for door made out of MS sheet 1.25mm thick of size 105mmx60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc. including filling of concrete 1:3:6 type C-1 back of chowkats complete all as specified and directed. |
| 4 | S&F pressed steel frame for doors made out of MS sheet 1.25mm thick of size 125mmx60mm for with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc. including filling of concrete 1:3:6 type C-1 back of chowkhats complete all as specified and directed. |
| 5 | S&F 35mm thick, 2nd class hard wood plain framed, panelled (factory made) shutters (two panels) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS-1003 (Part-I) kiln seasoned and chemically pressure treated, fitted to chowkats complete all as specified and directed. |
| 6 | S&F 35mm thick 2nd class hard wood in glazed and Skelton factory made shutters open rebated and prepared to receive glass/wire gauge etc. with sash bars edges of framing plain, chamfered or rounded fitted with cut and mitered beads for securing glass/wire mesh etc. sizes of members as per clause 8.24(a) of SSR Part-I complete all as specified and directed. |
| 7 | S&F factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other frame/Chowkhat of size 45x70mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum , screw withdrawal strength of 2200N (Face) & 1100N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with properly of being termite/borer proof, water/moisture proof and fire retardant 152 Section 8 and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length, complete all as specified and directed. |
| 8 | M&L sliding door bolt 250mm thick Stainless steel ISI Marked with hasp & staple bolt type and fixing clips of sheets SS section and fixing bolts and sliding bolts or extruded section all as specified. |
| 9 | S&F floor door stopper of overall length of cover plate 140mm aluminium alloy body and tongue, anodised, with hard drawn steel spring fixed in floor complete all as specified and directed. |
| 10 | S&F 300mm long stainless steel ISI Marked, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, SS sections and fixing bolts and sliding bolts of SS sections and fixed |
| 11 | S&F Factory made Solid PVC Moulded Door Shutter with wood free EPS, 28 to 30mm thick (stiles) with 5 mm thick moulded prelam PVC sheet on the front face and 5 mm prelam PVC sheet on back face, supplying & fixing in the frame at site as per specification & drawing complete all as specified and directed. |
| 12 | S&F 150mm extruded aluminium alloy handle fabricated anodized ISI marked, complete all as specified and directed. |
| 13 | S&F 150mm long aluminium, anodized barrel tower bolts of extruded section ISI marked, complete all as specified and directed. |
| 14 | S&F in repair, 300mm, Mild steel spring for door, ordinary rat tail rod pattern springs, including roller and roller plate complete all as specified. |
| 15 | S&F 100mm long butt hinges medium weight cold rolled ISI marked mild steel complete all as specified and directed including necessary welding if required . |
| 16 | S&F galvanized mild steel wire cloths 0.46mm nominal dia and average width of aperture 1.18mm & fixed with tint tacks or galvanized wire staples complete all as specified and directed. |
| 17 | S&F Anodised Aluminium expanded welded mesh/ Grill for wire gauged door shutter over stainless steel wire mesh complete all as specified and directed. |
| 18 | M&L for Preparing the new steel surfaces of any description over 10cm width or girth priming with red oxide zinc chrome and applying two coats of synthetic enamel paint complete all as specified and directed. |
| 19 | M&L for two coats of synthetic enamel paint on new wooden surfaces including preparation of surface and one coat of pink primer all as specified. |
| 20 | Demolition of brick work stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc, complete all as specified and directed. |
| 21 | M&L for brick work in cement mortar 1:4 of old size sub class ‘B' bricks straight or curved on plan exceeding 6mtr mean radius, complete all as specified and directed. |
| 22 | All as per item 21 here-in-before, but except bricks. |
| 23 | M&L for brick work with sub class ‘B’ bricks straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4, complete all as specified and directed. |
| 24 | S&F Mild steel framed work such as grills, gratings using square/round bar with ends of bars shoulders/welded drilling holes for fixing of guard bars, complete all as specified and directed. |
| 25 | S&F factory made uPVC white colour casement (Openable) window double shutter , one glazed and other fly proof shutter side hung made of extruded profiles with wall thickness of 2.3mm ( + – 0.2mm). Window profile with hollow section with multi chamber,overall frame size (110mm x 58mm), sash (60mm x 73mm), T profile (One vertical length in between two shutters) (60mm x 74mm), Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket 1.2 +– 0.2mm thick, galvanized steel Frame (28mm x 21.5mm), sash (31mm x 27.5mm). T profile (27mm x 17mm) to be inserted in required profile, frame will be fixed to the wall with 8 mm x 100mm long fasteners. Hardware: [casement handle made of zinc alloyed (white powder coated), But Hinges of' zinc alloyed (white powder coated), transmission gear made of mild steel with multi point locking system] and 5mm thick glazing with selected quality glass and SS wire mesh complete for the following all as specified and as directed :- |
| 26 | area not exceeding 1.00 sqm each |
| 27 | area exc 1.00 sqm but not exceeding 2.00 sqm each |
| 28 | area exc 2.00 sqm each |
| 29 | S&F MS Grill powder coated as fixed in arrangements with UPVC windows/ ventilators fixed to frame of windows/Jambs of window/ventilators complete all as spd and directed |
| 30 | M&L rendering 15 mm thick on concrete in CM 1:3 in facia or edging of chajjas, ceiling and roof projection etc incl taking out pealed off plaster/concrete and making good to cracks in RCC surfaces in true line/shape by providing RCC 1:2:4 type B1 using 20mm graded crushed stone aggregate including all necessary from work to thickness at required at GF and FF finish even and smooth without using extra cement complete all as specified and as directed by Engr-in-Charge. NOTE - The rate will inclusive of scaffolding for single or double story including making holes in brickwork and making good in cement mortar. |
| 31 | Taking down cement plaster on brick or concrete surfaces any description including raking out joints hacking for key scrubbing down with water complete all as specified and directed. |
| 32 | M&L for Rendering 5mm thick in cement mortar 1:3 on fair faces of brick work or concrete surfaces finishing the surface even and smooth without using extra cement as in ceiling complete all as specified. |
| 33 | M&L for preparation of new plastered or unplastered surfaces of ceiling including cornices plasters and applying two coats of oil bound distemper on ceiling, complete all as specified and directed. |
| 34 | M&L for complete removal of existing surfaces, preparation of old plastered or unplastered surfaces of ceiling including cornices plasters and applying two coats of oil bound distemper on ceiling, complete all as specified and directed. |
| 35 | M&L for Rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces finishing the surfaces even & smooth without using extra cement including scaffolding upto 7 meter height and curing the surface, complete all as specified and directed. |
| 36 | Material & Labour for applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces all as specified and directed |
| 37 | Material & Labour for applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old plastered surfaces of wall .all as specified and directed |
| 38 | M&L for Rendering 10mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces finishing the surfaces even and smooth without using extra cement and curing the surface, complete all as specified and directed. |
| 39 | M&L for applying 1mm wall care putty on walls and make the surface of level, including preparation of new plastered surface of wall and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed. |
| 40 | M&L Complete removal of existing treatment from internal surfaces of walls by wire brushing and washing, rubbing down and stopping of surfaces, & applying avg 1mm wall care putty on walls and make the surface of level, clean and repair disturbed edgs of bricks/concrete walls finish to even and smooth and applying two coats of oil bound distemper over old surface all as spd and directed by Engr-in-Charge. |
| 41 | M&L for Non skid ceramic colour tiles 7 to 8 mm thick (sq/ rect) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 15mm thick screed bed in cement mortar 1:6 including dismantling of floor tiling incl cement mortar bedding (but not backing)removing serviceable tiles to a store and rubbish off premises complete all as specified and directed. |
| 42 | M&L for providing glazed ceramic coloured wall tiles of size 300mmx600mmx7mm thick, set, jointed in colour cement to match laid over and including 10 mm thick rendering in cement mortar 1:4 including dismantling of wall tiling, complete all as specified and directed. |
| 43 | M&L for Non skid ceramic colour tiles 7 to 8 mm thick (sq/ rect) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 15mm thick screed bed in cement mortar 1:6 including dismantling of floor tiling incl cement mortar bedding (but not backing)removing serviceable tiles to a store and rubbish off premises complete all as specified and directed. |
| 44 | Description all as per serial item No. 40 above but on vertical surface over rendering 10mm thick in cement mortar 1:4, complete all as specified and directed. |
| 45 | M&L for 75mm thick levelling course in cement concrete type B-1 1:2:4 using 20mm graded aggregate complete all as specified and directed. |
| 46 | M&L for 25mm thick cement concrete type B-0 1:2:4 using 12.5mm graded aggregate as in floor complete all as specified and directed. |
| 47 | Taking up or down GI pipes 20mm bore and connection including cleaning for refixing or removal un-serviceable pipe from site, complete all as specified and directed. |
| 48 | S & F steel water tubing of size 20 mm bore, medium grade, galvanised iron with all Fittings such as Tees, elbows, sockets, bends, unions, shortpieces, nipples, brass nuts and diminishing pieces complete all as per IS 1239, fixed to wall and ceiling complete all as specified and as directed by Engr-in-Charge. |
| 49 | All as per item No 45 here in before but except tubing |
| 50 | Taking up or down GI pipes 15mm bore and connection including cleaning for refixing or removal un-serviceable pipe from site, complete all as specified and directed. |
| 51 | S & F steel water tubing of size 15mm bore, medium grade, galvanised iron with all Fittings such as Tees, elbows, sockets, bends, unions, shortpieces, nipples, brass nuts and diminishing pieces complete all as per IS 1239, laid in wall complete all as specified and as directed by Engr-in-Charge. |
| 52 | All as per item No 48 here in before but except tubing |
| 53 | M&L for cutting chases, pinning in brick work for concealed water tubing and making good to facings where required and pointed in cement mortar 1:3 cutting not exceeding 10cm girth, complete all as specified and directed. |
| 54 | S&F in repair vitreous china wash down water closet pan (Orissa patern) white with integral foot rest of of size 580x440mm white with integral foot rest (excluding flushing cistern and flush pipe), including connection to trap, and to flushing pipe, anty syphonage pipe etc. and including 'P' and 'S' trap complete incl making good to floor complete all as specified and directed. |
| 55 | S&F in repairs 10 liters PVC low level flushing cistern (white colour) syphonic action type with inlet ball valve float and push type handle including bracket, PVC 32mm dia flush pipe with coupling and fixed complete all as specified and directed. |
| 56 | S&F in repair vitreous china wash down water closet (pedestal pattern) white colour including P or S trap, fixing bolts and connecting to drain pipe, including seat cover plastic flat bottom, Butterfly Stainless Steel Jet or Bidet hands free spray and Stainless Steel Chromium plated hinging device and connection to flush pipe, anti syphonic pipe etc complete all as specified and directed. |
| 57 | Supply & fixing of CP health faucet with ABS body, Stainless Steel hose, 1.20mtr flexible SS tube & hook fixed with and incl CP screws complete all as specified and directed. |
| 58 | S&F in repair Toilet paper holder with flat recessed type stainless steel incl CP screws Complete all as specified and directed. |
| 59 | S&F in repair bib taps long body, fancy type, chromium plated, cast copper alloy ISI marked with crutch or butter fly handle high pressure screwed down screwed for iron pipe of 15mm bore, complete all as specified and directed. |
| 60 | S&F in repair vitreous china wash hand basin (flat back or angle back type) coloured of bowl size 550mmx400mm including waste and waste pipe PVC 32mm dia to be fixed over marble slabs or iron brackets complete all as specified and directed. |
| 61 | S & F pedestal stand for wash hand basin of size 550x400mm of matching colour of wash hand basin complete all as spd & directed. Make Jaguar or Technocommercial or equivalent. |
| 62 | S&F in repair 5mm thick looking mirror of size 600x450mm of selected quality glass mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 63 | S&F in repair for Bathroom cabinet mirror of size 450mmx350mm wall mounted, shape rectangular fixed to walls with plugs and screws complete all as spd & directed. |
| 64 | M&L for water proofing treatment to sunken slab, walls, etc, and shall be carried out as specified below and as directed.(a) Clean the sunken portion of toilet / Baths/ WCs/ Kitchen thoroughly to remove laitance, dirt, dust etc.(b) Form angle fillet of size 40 mm x 40 mm along the junction of wall and floor using polymer modified mortar (“ Dr fixit” Pidicrete URP” or eqvt).(c) Sanitary pipes entering through walls and floor shall be sealed with “Dr Fixit Bath seal Tape” and the gaps to be grouted with non-shrink cementitious grout “Dr Fixit Bath seal Grout” or eqvt. Nahani traps etc to be fitted securely and the gaps around it to be grouted in the same manner.(d) Apply one coat of a Bitumen-modified polymer coating “Dr Fixit Bath seal Plus” or eqvt on all angle fillets by brush and cover it with 100mm open woven mesh when it is still wet. Apply second coat of the same coating on the angle fillets and allow it to dry completely.(e) In the remaining area, in dry substrate condition brush apply first coat of the same coating and further apply second coat when first is dry. Extend the coating upto 150mm above the FFL. Above FFL, another cementitious waterproofing waterproof coating “Dr Fixit Pidifin 2 K” or eqvt can be further applied right upto 2.1 m to waterproof the shower area also, if it is a bathroom or bath cubicles of a sanitary annex and apply second coat after 6-8 hours and allow to dry completely.(f) After 2 to 3 days, sunken portion must be overlaid with a 50 mm thick concrete screed 1:3:6 type B0 mixed with integral WPC (Liquid) laid to slope 1:60 towards outer face of wall. Provide 40 mm OD UPVC pipe at the lowest point with 300 mm projection beyond the outer face of the wall. Then fill up the sunken portion with lean concrete 1:5:10 type E2.(g) After completing plumbing work in the toilet/WC/Bath/Kitchen floor, tiling work (floor and dado) can be carried out using suitable Tile Adhesives and ready to make tile grouts of approved makes such as Dr Fixit, FOSROC, SIKA etc. |
| 65 | S&F in repair Stain less steel curtain rods 25mm dia factory fixed, complete all as specified and directed. |
| 66 | S&F in steel brackets for 25 mm dia rod fixed with screws and gutties in wall and fixed to curtain rod with screws of design/shape, complete all as specified and directed. |
| 67 | All as per serial item No. 63 here-in-before, but end caps with wall ornament and fixed to curtain rod with screws of design/shape all as specified and directed . |
| 68 | S&F brass chromium plated tubular towel rail 20mm dia D type 61cm long between flanges, complete all as specified and directed. |
| 69 | S&F in repair CP towel ring PTMT fixed with and including Chromium plated brass screws and cleats (min wt 90 gms), complete all as specified and directed. |
| 70 | S&F Sheet glass shelf assembly consisting of 5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 50cm long complete all as specified and directed. |
| 71 | S&F Corner glass shelf assembly consisting of 5mm thick sheet glass shelf 30cm wide with chromium plated bracket guard and railing complete all as specified and directed. |
| 72 | S&F in repair mild steel, chromium plated Soap Dish fixed with and incl CP screws all as specified and directed. |
| 73 | S&F in repair PVC connection 15mm bore size with PTMT nuts of length 450mm complete all as specified and directed. |
| 74 | S&F in repair Swan Neck Sink cock for kitchen with regular swinging spout with flange complete all as specified and directed. |
| 75 | S&F in repair Basin Mixer swan neck tap, cast copper alloy chromium plated with capstan heads screwed down high pressure or without lettered hot or cold with long screwed, shanked and fly nuts screwed for iron pipe 15mm dia complete all as specified and directed. |
| 76 | S&F in repair CP Brass Wall Mixer for bathroom tap cast copper alloy chromium plated with flange and capstan heads screwed down high pressure for mixing hot or cold water with long screwed, shanked and fly nuts screwed for iron pipe 15mm dia complete all as specified and directed. |
| 77 | S&F in repairs 15mm bore angle valve chromium plated with flange screwed down fancy type high pressure screwd both ends for iron pipe of 15mm bore complete all as specified and directed. |
| 78 | Supplied and fixed in repair stop valves (ISI marked), 15mm dia, cast copper alloy, chromium plated fancy type with long shank and cup (concealed type) screwed down, high pressure with crutch or butter fly handle, screwed both ends for iron pipes or for unions and fixed in pipe, complete all as specified and directed. |
| 79 | S&F in repair chromium plated shower 150x150mm square fixing with 15mm pipe incl shower arm 240mm size complete all as specified. |
| 80 | S&F grating square 100x 100 mm size of stain less steel as in repair, complete all as specified and directed. |
| 81 | M&L in repairs 100mm PVC floor trap/ Nahani trap, including fixed in cement type B-1 (1: 2:4) complete all as specified and as directed. |
| 82 | M&L 110mm PVC (SWR) junction Single Tee (Single T) equal or unequal complete all as spd & directed. |
| 83 | M&L 75mm PVC (SWR) junction Single Tee (Single T) equal or unequal complete all as spd & directed. |
| 84 | M&L 75mm PVC Branch pieces, double (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified and directed. |
| 85 | S&F for 75mm bore PVC (SWR) vent cowl as in repair complete all as specified and directed. |
| 86 | S&F PVC (SWR) pipes single sockets in any length with rubber ring joints laid in trenches or in floors, 110mm bore complete all as specified and directed. |
| 87 | Description all as per serial item No. 83 above but 75mm bore. |
| 88 | S&F PVC (SWR) bends of 75mm bore any radius complete all as specified and directed. |
| 89 | S&F PVC (SWR) bends of 110mm bore any radius complete all as specified and directed. |
| 90 | S&F PVC (SWR) reducers of 75mm bore any radius complete all as specified and directed. |
| 91 | Taking down old eaves gutters and rainwater pipes (any size or pattern) , including all fitting ,head ,shoes ,bend, swan-necks etc., including cleaning or refixing or removal to store . |
| 92 | S&F, 110mm bore, PVC rainwater (SWR) drainage pipes single socketed, in any length with rubber ring joints as in repair, fixed to walls with sufficient number of Iron stack clamp complete all as specified and directed. |
| 93 | S&F, 75mm bore, PVC rainwater (SWR) drainage pipes single socketed, in any length with rubber ring joints as in repair, fixed to walls with sufficient number of Iron stack clamp complete all as specified and directed. |
| 94 | S & F in repair for Bathroom Duct Pipelines for Domestic Water Pipes downtake pipes fixing done with Pipe Supporting Clamping System having Profile Bracket + Slotted C Channel + U Bolt R/M System - 1. Domestic Water Supply Down take lines 1/2\\" GI - 2 nos. from Terrace to 1st Ground Floor Vertical Fixed line with wall distance 2\\": Pipe Support Clamping made of 1. Profile Bracket Wall Distance 2\\" made of Low Carbon Hot Roll gauge corrected Oil Pickeled & Drawn (HROP D) Steel (IS 1079); material size 32 mm x 3 mm with ribs and notch are Hot Dip Galvanzied + Zn Al Flake coated having Salt Spray Test (Test method - ASTM B-117-2019) result above 2000 hrs with SS304 Hex Flange Bolt with Serration 5/16 x 3/4 (A/F 13mm) as per DIN 6921and SS304 Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration as per DIN 6923. 2. Slotted \\"C\\" Channel B3 Type to be used of size 12\\" (Continuous Slotted \\"C\\" Channel with ribs) made of Low Carbon Hot Roll gauge corrected Oil Pickeled & Drawn (HROP D) Steel (IS 1079) are Hot Dip Galvanzied + Zn Al Flake coated with material thickness of 3mm. 3. U bolt R/M are made of low carbon mild steel with Rod diameter 7 mm approx.; Zn Al Flake coated with noise absorbing transparent ribbed silicon rubber sleeve; with Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration set as per DIN 6923 - Zn Al Flake coated.Hotdip Galvanizing as per IS 2629 (1985) - 610 grams/m2 (> 85 microns). Material Grade : IS 1079 used as per MTC confirms to EN 10204 3.1. Material Qty.: 1. Profile Bracket Wall distance 2\\" - 2 Nos. 2. Continuous Slotted C Channel of B3 Type Size 12\\" - 1 No.; 3. U Bolt R/M for 1/2\\" GI pipe Dia. - 2 nos. 4. Justi Khilla GI coated 2 1/2\\" - 4 nos. Pipe Support Clamping Unit fixing to be done at every metre distance in the duct as specified and directed. |
| 95 | S & F in repair of Toilet Duct Pipelines for Soil Water Down take pipe fixing done with Pipe Supporting Clamping System having Mono Bracket + U Bolt System - 1. Soil Water Pipe 4\\" PVC - 2 pipe running from Terrace to Ground Floor Vertical Fixed line with wall distance 3\\": Pipe Support Clamping made of 1. Mono Bracket with Slot Wall Distance 3\\" for 4\\" PVC pipe made of Low Carbon Hot Roll gauge corrected Oil Pickeled & Drawn (HROP D) Steel (IS 1079); material size 48 mm x 3 mm with ribs and notch are Hot Dip Galvanzied + Zn Al Flake coated having Salt Spray Test (Test method - ASTM B-117-2019) result above 2000 hrs. 2. U bolt R/M are made of low carbon mild steel with Rod diameter 7 mm approx.; Zn Al Flake coated with noise absorbing transparent ribbed silicon rubber sleeve; with Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration set as per DIN 6923 - Zn Al Flake coated. Hotdip Galvanizing as per IS 2629 (1985) - 610 grams/m2 (> 85 microns). Material Grade : IS 1079 used as per MTC confirms to EN 10204 3.1. Material Qty.: 1. Mono Bracket with Slot Wall distance 3\\" for 4\\" PVC pipe - 1 Nos. 2. U Bolt R/M for 4\\" PVC Pipe Dia. - 1 Nos. and 3. Justi Khilla GI coated 2 1/2\\" - 2 nos. Pipe Support Clamping Unit fixing to be done at every metre distance in the duct as specified and directed. |
| 96 | S & F in repair for Bathroom Duct Pipelines for Domestic Water Pipes downtake pipes fixing done with Pipe Supporting Clamping System having Profile Bracket + Slotted C Channel + U Bolt R/M System - 1. Domestic Water Supply Down take lines 1/2\\" GI - 2 nos. from Terrace to 1st Ground Floor Vertical Fixed line with wall distance 2\\": Pipe Support Clamping made of 1. Profile Bracket Wall Distance 2\\" made of Low Carbon Hot Roll gauge corrected Oil Pickeled & Drawn (HROP D) Steel (IS 1079); material size 32 mm x 3 mm with ribs and notch are Hot Dip Galvanzied + Zn Al Flake coated having Salt Spray Test (Test method - ASTM B-117-2019) result above 2000 hrs with SS304 Hex Flange Bolt with Serration 5/16 x 3/4 (A/F 13mm) as per DIN 6921and SS304 Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration as per DIN 6923. 2. Slotted \\"C\\" Channel B3 Type to be used of size 12\\" (Continuous Slotted \\"C\\" Channel with ribs) made of Low Carbon Hot Roll gauge corrected Oil Pickeled & Drawn (HROP D) Steel (IS 1079) are Hot Dip Galvanzied + Zn Al Flake coated with material thickness of 3mm. 3. U bolt R/M are made of low carbon mild steel with Rod diameter 7 mm approx.; Zn Al Flake coated with noise absorbing transparent ribbed silicon rubber sleeve; with Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration set as per DIN 6923 - Zn Al Flake coated. Hotdip Galvanizing as per IS 2629 (1985) - 610 grams/m2 (> 85 microns). Material Grade : IS 1079 used as per MTC confirms to EN 10204 3.1. Material Qty.: 1. Profile Bracket Wall distance 2\\" - 2 Nos. 2. Continuous Slotted C Channel of B3 Type Size 12\\" - 1 No.; 3. U Bolt R/M for 1/2\\" GI pipe Dia. - 2 nos. 4. Justi Khilla GI coated 2 1/2\\" - 4 nos. Pipe Support Clamping Unit fixing to be done at every metre distance in the duct as specified and directed. |
| 97 | S & F repair of Toilet Duct Pipelines for Soil Water Down take pipe fixing done with Pipe Supporting Clamping System having Mono Bracket + U Bolt System - 1. Soil Water Pipe 4\\" PVC - 2 pipe running from Terrace to Ground Floor Vertical Fixed line with wall distance 3\\": Pipe Support Clamping made of 1. Mono Bracket with Slot Wall Distance 3\\" for 4\\" PVC pipe made of Low Carbon Hot Roll gauge corrected Oil Pickeled & Drawn (HROP D) Steel (IS 1079); material size 48 mm x 3 mm with ribs and notch are Hot Dip Galvanzied + Zn Al Flake coated having Salt Spray Test (Test method - ASTM B-117-2019) result above 2000 hrs. 2. U bolt R/M are made of low carbon mild steel with Rod diameter 7 mm approx.; Zn Al Flake coated with noise absorbing transparent ribbed silicon rubber sleeve; with Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration set as per DIN 6923 - Zn Al Flake coated. Hotdip Galvanizing as per IS 2629 (1985) - 610 grams/m2 (> 85 microns). Material Grade : IS 1079 used as per MTC confirms to EN 10204 3.1. Material Qty.: 1. Mono Bracket with Slot Wall distance 3\\" for 4\\" PVC pipe - 1 Nos. 2. U Bolt R/M for 4\\" PVC Pipe Dia. - 1 Nos. and 3. Justi Khilla GI coated 2 1/2\\" - 2 nos. Pipe Support Clamping Unit fixing to be done at every metre distance in the duct as specified and directed. |
| 98 | S & F in repair for Bathroom Duct Pipelines for Waste Water Pipe downtake pipes fixing done with Pipe Supporting Clamping System having Profile Bracket + Slotted C Channel + U Bolt R/M System - 1. Waste Water Pipe 4\\" PVC Down take running from 1st Floor to Ground Floor Vertical Fixed line with wall distance 3\\": Pipe Support Clamping made of 1. Profile Bracket Wall Distance 3\\" made of Low Carbon Hot Roll gauge corrected Oil Pickeled & Drawn (HROP D) Steel (IS 1079); material size 32 mm x 3 mm with ribs and notch are Hot Dip Galvanzied + Zn Al Flake coated having Salt Spray Test (Test method - ASTM B-117-2019) result above 2000 hrs with SS304 Hex Flange Bolt with Serration 5/16 x 3/4 (A/F 13mm) as per DIN 6921and SS304 Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration as per DIN 6923. 2. Slotted \\"C\\" Channel B3 Type to be used of size 10\\" (Continuous Slotted \\"C\\" Channel with ribs) made of Low Carbon Hot Roll gauge corrected Oil Pickeled & Drawn (HROP D) Steel (IS 1079) are Hot Dip Galvanzied + Zn Al Flake coated with material thickness of 3mm. 3. U bolt R/M are made of low carbon mild steel with Rod diameter 7 mm approx.; Zn Al Flake coated with noise absorbing transparent ribbed silicon rubber sleeve; with Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration set as per DIN 6923 - Zn Al Flake coated.Hotdip Galvanizing as per IS 2629 (1985) - 610 grams/m2 (> 85 microns). Material Grade : IS 1079 used as per MTC confirms to EN 10204 3.1. Material Qty.: 1. Profile Bracket Wall distance 3\\" - 2 Nos. 2. Continuous Slotted C Channel of B3 Type Size 10\\" - 1 No.; 3. U Bolt R/M for 4\\" PVC Pipe Dia. - 1 nos. and 4. Justi Khilla GI coated 2 1/2\\" - 4 nos. Pipe Support Clamping Unit fixing to be done at every metre distance in the duct as specified and directed. |
| 99 | S&F UPVC underground drawings pipe (UDS) type 'B' 160mm dia with wall thickness 4mm (min) and pressured 4 KN /Mtr Sq jointed in cement solvent complete including providing 100 mm thick cement concrete (1:4:8) type D-2 using 40mm graded crushed stone agg as in bed for 160mm bore pipes incl packing under and haunching against the sides of pipes after they are laid tested including taking down old damaged SGSW pipes from existing lines including necessary excavation of old fitted in trenches complete all as specified and directed. |
| 100 | M&L for cutting into existing manholes for connecting new drains/ pipe of any dia, making good to pipe and making good of broken manhole. |
| 101 | M&L for Jet Black granite18- 20 mm thick Machine cut , pre polished, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone as in kitchen platform , flooring including grinding mirror polishing and half moulding laid over 15 mm thick screed bedding in cement mortar 1:6 and all other similar works complete all as specified and directed. |
| 102 | S&F in repair Stainless steel plate rack of size (775mm x 750mmx250mm ) made out of AISl 304 stainless steel 1.00 mm thick sheet fixed with screw of required size including necessary fittings/nuts, bolts & washers complete all as specified and directed. |
| 103 | S&F sinks made of stainless steel w/o drainage board 1mm thick kitchen or laboratory with plugs, washers and wastes pipe and waste coupling including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, bowl size 508mm x 406mm x 205mm complete all as specified and directed. |
| 104 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 105 | M&L for reinforced cement concrete as in shelf (1:2:4) type B-1 using 20mm graded crushed stone aggregate as in cover slabs kitchen platform, shelves and similar articles including necessary moulds/formwork set in cement mortar (1:6), complete all as specified and directed. |
| 106 | M&L for Mild steel TMT bars 10mm dia and over cut to length bent to shape required including cranking, bending, binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 107 | M&L for Formwork to soffits of Kitchen cooking platform slabs and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and as directed |
| 108 | S&F Rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) hoisted fixed in position all as specified in SSR part-I, capacity of tank 1000 ltr incl inlet and outlet connection 20mm dia and 15mm dia GI pipes medium grade respectively 20mm GI pipe medium grade over flow pipe 15cm long and PTMT valve 20mm high pressure with polyethylene float and fly nuts including dismantling water tanks (capacity of tank exc. 500 ltr but n. exc. 1000 ltr) and removing from site complete all as specified and directed. |
| 109 | M&L for 20mm dia Gun metal globe or gate valve with iron wheeled head, screwed both ends for iron and fixed in repairs complete all as specified and directed. |
| 110 | S&F in repair SS chromium plated, plated peg set of six fixed with screw complete all as specified and directed. |
| 111 | S&F in repairs Door Sweep sealing/ Door seal (Snake guard) with Aluminium frame powder coated & Nylon brush brown colour for door opening complete all specified |
| 112 | Demolition of stone slabs, paver blocks and tiles of any description or thickness in floors/apron laid dry complete all as specified and directed. |
| 113 | S&F machine pressed precast concrete interlocking paver blocks with grey cement and pigment, any shape and size conforming to IS 15658:2006 of 60 mm thickness M35 grade complete all as specified and directed. |
| 114 | M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. |
| 115 | M&L for 75mm thick PCC (1:3:6) type C2 using 40mm graded crushed stone aggregate as in sub base/ floor complete all as specified and directed |
| 116 | Rounding to edges of stone slabs, one edge, such as in steps, cooking platform and other similar situation, complete all as specified and directed. |
| 117 | M&L for diamond cut kota stone slab flooring 18-20 mm thick over cement screed bese laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing to mirror finish inluding Screed bed or bedding layer of mortar 20 mm thick in (1:6) for laying floor finishes complete all as specified and directed. |
| 118 | All as per serial item No. 114 here-in-before, but on vertical surfaces on 10mm thick CM 1:4 all as specified and directed . |
| 119 | M&L for Non abrasive paving (rectified endura) heavy duty cement concrete coloured tiles 300x300mmx10mm thick set jointed and pointed in neat cement slurry mixed with pigment laid over 15mm thick screed bed in cement mortar 1:4 including demolition/dismantling old surface/tiles complete all as specified and directed. |
| 120 | Description all as per serial item No 116 here in before but on vertical surfaces on 10 mm thick CM 1:4. |
| 121 | M&L for 50mm thick PCC, type C-1, 1:3:6, ( using 20mm graded crushed stone aggregate) as in plinth protection finishing the surface complete all as specified and directed. |
| 122 | Dismantling timber scantlings unframed 40 sq cm and over in section, in any position complete all as specified and directed. |
| 123 | S&F for Steel hollow section as in main and cross beams, hip and jack rafters, purlins where connected to common rafter and running rails and guides for sliding door fixed with angle cleat or other connecting plates etc complete conforming to IS:4923-1979 of Fe-410W (Grade E-250) quality A complete all as specified and directed. |
| 124 | M&L Prepainted galvalume aluminum zinc coated GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength 550 Mpa as in roof covering/cladding to walls, fixed with self taping screws and overlap with sufficient laps incl dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings, complete all as specified and directed by Engineer-in-Charge. |
| 125 | M&L for plain cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate in copings, bed plates including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete all as specified and directed |
| 126 | Demolition of Concrete of any description (unreinforced) and in any position, complete all as specified and directed. |
| 127 | M&L for PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) as in padding over roof slab for providing proper slope, and finishing the surfaces even & smooth without using extra cement, complete all as specified and directed. |
| 128 | M&L for liquid water proofing treatment to RCC roof slab incld dismantling of existing treatment of any description in following procedure : (a) Laying 10mm thick rendering in Cement mortar 1:4 mixed with WPC 3% by weight of cement on fair faces of concrete roof surfaces , finished even and fair to receive treatment on roof Complete (b) Applying first coat fiber reinforced elastomeric liquid water proofing membrane formulated with PU hybrid polymers and reinforcing acrylic fibers with sun reflective index (SRI) of 100-110, having minimum elongation of 350%, tensile strength 2.9 Mpa and shall have reack bridging ability upto 2.5mm and shall resist 10 bars of hydrostatic pressure reduce surface temperature upto 10 degree celsius with 3.3% dilution as priming coat (c) laying of fiber mesh 0.3mm thickness weave in leno pattern having weight 4.5 gm/ Sqm and pasting it properly with overlap of 50mm and allow it to dry (d) Applying second coat undiluted @ 0.45 ltr/ sqm as directed by Engr-in-Charge (e) Applying third and final coat undiluted @ 0.45 ltr/ sqm as directed by Engr-in-Charge. (The rate includes for filling cracks in existing roof with cement putty using suitable bonding agent (shalcrate 42) before laying cement plaster) |
| 129 | Dismantling brick tiles or terracing tiles, single layer on roofs all as specified and directed. |
| 130 | M&L for 40 mm thick brick tiles bedded in cement mortar (1:6), 15mm thick and joints grouted flush in cement mortar (1:3) mixed with 5% of cruded oil by weight of cement complete all as specified and directed. |
| 131 | All as per item No 127 but except Brick tiles. |
| 132 | S&F prelaminated 18 mm thick lead free factory made 100 % solid WPC (wood polymer composite) sheet having high natural fiber content 25 to 30 % wood colour sheets with density not less than 500 Kg/Cum and the weight of sheet of 1 Sqm should be 11 Kg(+- 5%) manufactured by ISO 9001-2015 certified company. The sheet should be 100 % water proof, termite proof ,fire retardant, manufactured by single layer extrusion process with excellent screw holding capacity and shore D hardness, complete all as specified and directed. |
| 133 | S & F continuous piano hinges (30mm width of flaps when open) mild steel, bright finish complete all as specified and directed |
| 134 | S&F Stainless Steel Oval Closet hanger Rod for hanging clothes in cupboards with End Supports/ End caps 3cm complete all as spd and directed & approved by engr in charge. |
| 135 | S&F 100mm Hasp and staple, safety type, stainless steel including bolt to hinge plate and fixed with screws complete |
| 136 | S&F magnetic door catches with sticking plate of standard size for cupboard/cabinet doors approved by GE as specified and directed. |
| 137 | S&F 125mm size, stainless Steel handles, fabricated type, ISI Marked, complete all as specified and directed. |
| 138 | S & F of stainless steel 304 grade electro-polished for corrosion resistance modular thali holder / basket having size of 42 x 58.5 x 20 cm including telescopic drawer channel having weighing capacity of 6 kg complete all as specified and directed. |
| 139 | S & F of stainless steel 304 grade electro-polished for corrosion resistance modular cup & saucer holder / basket size of 52 x 53.5 x 10 cm with telescopic drawer channel having weighing capacity of 4kg complete all as specified and directed. |
| 140 | S & F SS 304 grade 200mm length stainless steel cabinet drawers with handles complete all as specified and directed. |
| 141 | S & F in repairs of stainless steel grain trolley SS 304 grade having size of 525x485x350mm, with heavy duty and grade steel with finish of zinc, corrosion resistance with telescopic drawer channel having weighing capacity of 25 kg complete all as specified and directed. |
| 142 | S & F in repairs of stainless steel Plane wire Basket/ trolley SS 304 grade having size of 506x480x200mm, with heavy duty and grade steel with finish of zinc, corrosion resistance with telescopic drawer channel having weighing capacity of 25 kg complete all as specified and directed. |
| 143 | S&F stainless steel modular perforated cutlery basket SS 304 grade of size 52x48.5x10 cm with telescopic drawer channel having weighing capacity of 6 kg complete all as specified and directed. |
| 144 | S&F stainless steel 304 grade Size 180x515x485 mm pull out detergent rack having two shelf spaces with telescopic drawer channel having weighing capacity of 6 kg complete all as specified and directed. |
| 145 | Clean existing reinforcement with wire brush/rotary wire brush to make surface free from rust scales, loose material, dirt etc complete and providing applying two coats of rust remover and two coats of alkaline rust converting primer/zinc primer and form a corrosion resitant, insoluble and adherent protective layer, including cleaning the reinforcement, wire brushing to remove loose rust spalls, with time interval of 1 hour between the coats use in beams, complete all as specified and directed. |
| 146 | All as per item No 142 but in Slab/ Wall/ Chajja |
| 147 | Providing and applying, brush application, curing to form anticorrosive with high bond strength of anticorrosive polymer modified cementitious coating for corrosion inhibiting protection of reinforcement in one layers of total thickness of 2 mm in beams. |
| 148 | All as per item No 144 but in Slab/ Wall/ Chajja. |
| 149 | Rebuilding the section of damaged RCC elements to its original size or as directed by Engineer-in-Charge in thickness exceeding 40 mm but not exceeding 100mm by providing and casting with pre-packed dual shrinkage compensated micro concrete of minimum grade of M40 and above including providing and fixing of watertight foam faced finish shuttering all lead and lift mixing placing, deshuttering, levelling the surface by grinding off cementitious slurry of construction joints of differences in any to satisfaction of Engr-in-charge, curing etc in beams complete all as specified. |
| 150 | Rebuilding the section of damaged RCC elements to its original size or as directed by Engineer-in-Charge in thickness not exceeding 60 mm in layers of min thickness exceeding 20 mm and avg thickness 40 mm each by providing and applying ready mixed duel shrinkage compensated thixotropic mortar (PMM) of minimum grade M40 and above, including all lead lift, mixing by addition of water only as per manufacture's recommendation, levelling the surface, curing etc in Slab/Wall/Chajja complete all as specified. |
| 151 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed |
| 152 | Taking down distribution boards/wooden board ,switch fuse units, steel enclosures for MCB of any type and removing from site complete all as specified and directed. |
| 153 | Taking down existing unserviceable submain wiring of any size and making good the disturbed surface complete all as specified and directed. |
| 154 | M&L for modular point wiring with 1.5 sqmm (nominal area) PVC insulated FRLS and unsheathed multistranded copper conductor cable 1100 volts grade drawn through and including PVC rigid concealed conduit not less than 1.8 mm thick (ISI marked) with all accessories including suitable modular plate (Inner + Outer) and modular metallic boxes of suitable sizes including 1.5 sqmm PVC FRLS insulated unsheathed copper conductor multistranded cable for continuous earth conductor connected to common earth dolly, complete all as specified & directed for the following :- Note:- Proper colour coding is to be followed as per IS Specification. |
| 155 | One light point controlled by 5 Amp SP, one way, 240 Volts. |
| 156 | One ceiling/ exhaust fan controlled by 5 Amp SP, one way, 240 Volts. |
| 157 | One bell/ buzzer point controlled by one bell push |
| 158 | All as per item No. 151.00 here-in-before but for one light point controlled by two switch 6 Amp SP, two way, 240 Volts. |
| 159 | All as per item No. 151.00 here-in-before but for one 5 pin 6 Amp socket outlet point on same board |
| 160 | All as per item No. 151.00 here-in-before but for one 5 pin 6 Amp socket outlet point on independent board controlled by one way switch SP, one way 6 Amp, 240 Volts |
| 161 | All as per item No 151.00 here-in-before but using 2.5 Sqmm (nominal area) multistranded copper conductor cable including 2.5 Sqmm size FRLSH PVC insulated and sheathed copper conductor cable as earth conductor (green colour) connected to common earth dolly for one 6 pin socket outlet 16 Amps multi purpose on independent point complete all as specified and directed. |
| 162 | All as per item No 151.00 here-in-before but using 4.00 Sqmm (nominal area) multistranded copper conductor cable for geyser sheet metal plug socket outlet/metal plug top including 4.00 Sqmm size FRLSH PVC insulated and sheathed copper conductor cable as earth conductor (green colour) connected to common earth dolly for geyser on independent point complete all as specified and directed. |
| 163 | M&L for Sub main wiring in two single run FRLS PVC insulated cable 6 Sqmm (Nominal dia) copper conductor (multistrand) and drawing in and including new PVC concealed non metallic conduit pipe ISI marked including one run 6 Sqmm multistranded copper conductor FRLS PVC green colour insulated unsheathed cable for earth continuity complete all as spd and directed. |
| 164 | M&L for Modular switch 1 way 6A, 1 module complete all as specified and directed. |
| 165 | M&L for Modular switch, 2 way 6A, 1 module complete all as specified and directed. |
| 166 | M&L for Modular switch 1 way 16A, 1 module complete all as specified and directed. |
| 167 | M&L for Modular socket out let, 6 pin 5/6 and 15/16 amps multipurpose, 2 module 2 in 1 flush type, 240 volts with polycarbonate body complete all as specified and directed. |
| 168 | M&L for Modular socket 2 in 1, 6 amps 2/3 pin Combined 2 Module, 240 volts. with polycarbonate body complete all as specified and directed. |
| 169 | M&L for Modular bell push flush button, SP one module 5 amps 240 volts with polycarbonate body complete all as specified and directed. |
| 170 | S&F in replacement of MCB Protected Socket With sheet steel Enclosure single pole 20 Amp with 3 pin plug top for AC connection from Socket point to stabilizer complete all as specified and directed. |
| 171 | S&F Bell Ding Dong, AC 230 volt, Single Pole complete all as spd & directed |
| 172 | S & F lamp holder batten type polycarbonate body with back plate for batten fitting, fixing with proper round block all as directed by Engr-in-Charge. |
| 173 | Supply and fixing LED Lamp 9/10 watt B-22 holder base with polycarbonate body and aluminium heat sink warm white complete all as specified and directed by Engineer - in - Charge. |
| 174 | M&L for ceiling rose surface bakelite 2 to 3 terminals with polycarbonate body complete all as specified and directed. |
| 175 | S & F decorative wall light white in colour made up of polycarbonate body suitable for and including 9 watts retrofit LED lamp B 22 Base complete all as specified and directed. |
| 176 | S&F in replacement of LED lights fitting 1x 20W,minimum 3.5 feet 220V, AC decorative box type with driver, holder including LED tube light connecting up with flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 177 | S&F LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 178 | S&F in replacement of LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 179 | S&F of 5 star rated BLDC (Brush less direct current motor) ceiling fan 230 volts, single phase of 1200 mm Sweep with regulator double ball bearing type with minimum air delivery 210 CFM with service value shall not less than 6.0 B.E.E including blade, down rod, canopy cover white colour etc, connecting 3 core flexible copper conductor cable, complete all as specified and directed by Engr-in-Charge |
| 180 | Taking down and refixing of Exhaust fan any size or type from the existing site and refixing the same at same place after carrying out necessary repair work including two coats of synthetic enamel paint of any approved colour after cleaning etc. all as specified and directed by Engineer - in - Charge. |
| 181 | S&F exhaust fan, steel body AC single Phase. 230V of size 300 mm sweep with, blades, and frame and louvers complete all as specified and directed. |
| 182 | M & L for cutting hole in brick/stone masonary wall and provision of PCC 1:3:6 for making proper suitable size of hole to matching with size of exhaust fan for proper ventilation including MS bolts 04 Nos for fixing exhaust fan all as spd and directed.Note : (i) Rates are deems to be included to making the cutting hole smoothly and colour wash as per existing colour.(ii) Rates are deems to be including charges of hiring T & P, i.e. ladder square folding and insurance of labour deployed, being holes are made to be at mutlistorey bldgs of different height . |
| 183 | Supply and installing of the electric water storage heater of ABS body type of 25 ltr capacity with rated power 2 KW, 5 star rated, vertical type, thermally insulated mild steel tank with glass line coating inside the tank alongwith glass lined incoloy heating element with anti corrosive magnesium anode, NRV, thermostat, indicators and temperature adjustable knob including steel braided flexible connection for pipe of size 15 mm dia bore with G I hexagonal adopters/Nuts on the both sides for inlet ( cold water supply) & outlet ( hot water supply) and including provision of wall mounting arrangement and mounding wall with suitable size of anchor bolts with complete connection of water including testing after installation complete all as specified and directed by Engr-in-Charge . |
| 184 | Taking down electric energy meter single phase any size or type form the existing site and refixing the same at same place after carrying out necessary repair work and making the surface good to match with existing surface all as specified and directed by Engr-in-Charge. |
| 185 | S&F High performance IP66 LED Street light 20 watt, housing made of die-cast aluminium, with street optic lens, with all accessories and connecting up with and including provision of 3 core flexible copper wire of size 1.5sqmm from ceiling rose, and 20W LED light etc. drawn through and including 32mm bore GI light grade protection pipe upto 1.0m length with suitable fixing accessories on walls, complete all as specified and directed. |
| 186 | S & F SPN 8 way sheet metal enclosures factory made DB double door 230 V AC, 50 Hz AC 200 Amp rated bus bar complete all as specified and directed |
| 187 | S&F 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and directed. |
| 188 | S&F 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 40 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and directed. |
| 189 | S&F 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SPN 40 Amp current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 190 | S&F MCCB TP 125 Amp 415V 16KA fixed type suitable for VTPN DB complete with connection testing and commissioning complete all as specified and directed. |
| 191 | S & F VTPN DBs Double Door 4 way suitable for MCCB incomer, IP 43 protection 415 V AC, 50 Hz AC appropriate size of bus bar and neutral link complete all as specified and directed |
| 192 | M&L for earthing complete with galvanized steel earth plate electrode 60cmX60cm X6mm thick buried directly in ground (earth plate not less than 2.25 mtr deep below the normal ground level) with top edge of plate not less than 1.5 mtr below the normal ground level connected to galvanized earth lead wire of 4.0mm dia by means of nuts bolts, washers, check nuts of iron or steel including PCC pits and RCC cover in PCC 1:2:4 (type B-1) and necessary earth work in any type of soil medium grade GI watering pipe 20 mm dia with funnel and wire mesh and 15mm bore GI pipe light grade protection pipe upto test point etc including excavation and charcoal, common salt surrounded with 15cm all around the plate all as specified and shown in EP-3 of SSR Part-I. all specified |
| 193 | Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtrs in depth for laying of cables, pipes etc and getting out in any type of soil complete all as specified and directed. |
| 194 | Returning filling in including spreading, leveling and well ramming, in layers not exceeding 25 cm each layer of any type of soil complete all as specified and directed. |
| 195 | Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 196 | S&F GI tubing medium grade Galvanized of size 25 mm bore laid in trenches or ground/ in wall surfaces with and including all fitting complete all as specified and directed. |
| 197 | S&F GI tubing medium grade Galvanized of size 40 mm bore laid in trenches or ground/ in wall surfaces with and including all fitting, all as specified by Engr-in-charges. |
| 198 | M&L for cutting existing GI/CI pipe line of size 40/25 mm dia pipe making new connection for GI pipe including short pieces , inserting tees, bends ,sockets, union etc with existing water line, complete all as specified and directed |
| 199 | S&F stop valve 25 mm dia cast copper alloy screwed on high pressure with crutch or butterfly handle screwed bolts ends, for iron pipe or for union and fixed complete all as specified and directed. |
| 200 | Supply and laying in replacement of cable XLPE insulated armoured heavy duty electric cable with extruded insulation aluminium conductor, 1100 volts grade of cross sectional area 50 Sqmm 3.5 Core, complete all as specified and directed. |
| 201 | M & L for good quality dry sand cushioning to under ground electric cable on layer of 8 cm thick before laying the cable and second layer of 15 cm thick after laying the cable all as specified and directed. Note: Punned thickness of sand shall be measured. |
| 202 | Supply and laying sub class 'B' bricks of old size (230x115x75 mm) or of size locally available , laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge |
| 203 | Material and labour for replacement of GI tubing light grade 50 mm bore for passing through cables under the floor, along the wall or along the pole complete all as specified and directed . |
| 204 | Note: (i) In case the tenderer quotes different rates for similar item then lowest rate shall only be applicable for payment and contractor shall not have any claim on this account.(ii) The Schedule of Credit amount shall be deducted from the total of this schedule (BoQ) to arrive at Contract Sum. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail