| 1 | Civil Work: |
| 2 | Dismantling existing plaster including disposal of refuse as directed by Engineer-in-charge with in a distance of 60 mt. (200 feet) As Per PWD SI No. 706 |
| 3 | Foundation concrete 1:6:12 with cement Fine sand and 40 mm Brick ballast in all complete as per PWD SI.No. 273 |
| 4 | Providing and laying vitrified floor tiles in floor with size of 600x600 mm (thickness to be specified by manufacturer) with water absorption less than 0.08% and conforming to 1S :15622, of approved brand & manufacturer, in all colours and shades laid with cement based high polymer modified quickset tile adhesive (water based) conforming to IS:15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made seperately)as directed by the Engineer-incharges.as per CPWD Item No 11.49.2 |
| 5 | 25 mm thick 1:2:4 plain cement concrete floor with cement, approved coarse sand and 20 mm graded approved stone laid in panels finished with 3 mm. flooring coat of neat cement or cement and marble dust in 5:1 as specified over & including 75 mm. thick base concrete consisting of cement, local sand and brick ballast 40 mm gauge in the proportion of 1:4:8 and removing any over lapping mortar at the joints of panels if any and giving them a uniform finish including supply of all materials, labour and T & P etc. required for proper completion of the work as per SI.No. 601 |
| 6 | 12 mm. thick plaster with Cement, F/sand in 1:4 single coat on fair side of single or half brick wall of interior plastering upto two level including aries internal rounded angles not exceeding 80 mm in grith and finshed even and smooth no extra for mixing any additive required for proper completion of work Sl No. 584 |
| 7 | Supply and fixing of 32 mm flush Door commercial quality conforming etc complete as per SI.No. 470a |
| 8 | Providing & applying white cement based putty of average thicness 1 mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 9 | Finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade old work two or more coats applied @1.43 ltr/10 sqm over existing cement paint surface etc complete as per DSR No 14.66.1 |
| 10 | One priming coat and two coat of aoil bound distemper on new work including supply of all material labour and T&P etc complete as per SI.No. 649, 650 |
| 11 | Two coat painting over one coat primer as per SI.No. 641, 642 |
| 12 | Supply and laying of PVC Water storage tank sintex or equivalent triple layer etc complete as per DSR 18.48A |
| 13 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with onesteps CPVC solvent cement and testing of joints complete as per direction of Engineer in charge. (SI No.18.7.1.2.3) |
| 14 | Providing and fixing GI Pipes complete with G.I. fittings and clamps including making good the walls etc concealed pipe including painting with anti corrosive bitumastic paint cutting chases and making good the wall as per DSR No 18.11.1, 18.11.215mm Nominal dia pipes |
| 15 | 20mm Nominal dia pipes Please Enable Macros to View BoQ information |