| 1 | Dismantling plain or corrugated steel sheeting any gauge, thickness, including nainital or similar pattern roof covering etc ccomplete, all as specified & directed by Engineer-in-charge. |
| 2 | S&F 0.63 mm thick Galvanised, corrugated mild steel shetting with two corrugations side lap, fixed with coach screws, washers, and L - type or J-type or cranked hook bolts in lieu of screw in roof sheeting, walls etc. with grade of zinc coating 275 etc complete, all as specified & directed by Engineer-in-charge. |
| 3 | S&F 0.63 mm thick Galvanised, plain mild steel sheeting in ridges, hips, valley gutters , drip and straight flashings (length and girth as fixed ) with grade of zinc coating 275 fixed to corrugated sheets in roofs, walls etc. , etc complete all as specified and as directed. |
| 4 | M&L for preparation of new zinc (or galvanised) comouflage pattern surfaces to receive painting, by a coating with mordant solution including washing and cleaning and applying two coat synthetic enamel paint over a coat of zinc crome, red oxide etc all as specified. |
| 5 | Dismantling timber framed work as in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section, complete all as specified and as directed by Engr-in-Charge. |
| 6 | M&L for second class hard wood in scantling, clean sawn timber framed and fixed work complete, all as specified & directed by Engineer-in-charge. |
| 7 | Dismantling timber framed work as in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section, complete all as specified and as directed by Engr-in-Charge. |
| 8 | M&L second class hard wood plain fillets square, rectangular or triangular in section area exc 6 sq.cm & n.exc 13 Sq.cm, clean sawn, se-cured with nails or brads complete all as specified. |
| 9 | M&L 3mm thick Cover fillets of tempered hard board, 40mm wide and fixing with screws all as Specified |
| 10 | Plugging to walls complete for wood fillets, grounds moulding, etc. on cement concrete walls, at distance n. exc 1 mtr complete all as specified and as directed. |
| 11 | Dismantling wall and ceiling board or insulation boards any thickness including cover fillets complete, all as specified & directed by Engineer-in-charge. 2 |
| 12 | M&L for 12 mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete, all as specified & directed by Engineer-in-charge. |
| 13 | M&L for 9 mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work fixed in ceiling complete, all as specified & directed by Engineer-in-charge. |
| 14 | S&F in repair anodised aluminium snap grid of size 605 x 605 mm frame work for false ceiling incl hangers 6 mm dia (upto 1200 mm length ) adjusting level fixed to roof slabs/ roof truss by means of ceiling cleats made out of GI flats 40x3 mm size 60 mm long and expension hold fasteners 12.5 mm dia and 40 mm long complete all as specified. |
| 15 | M&L for 12 mm thick gypsum board in ceiling fixed with screws as per manufactureres instruction, complete all as specified and as directed by Engr-in-Charge. |
| 16 | S&F for 5mm thick transparent Perspex sheet fixing to aluminium frame /iron frame/wooden frame etc with self tapping screws/bolts etc including dismantling complete all as specified and directed. |
| 17 | Dismantling wrought iron or mild steel work of any description completely all as specified and directed |
| 18 | S&F Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 19 | S&F rolled mild steel section in framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc, complete drilled for fixing of steel sheeting or other covering doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings and hanging of grade Fe 410-W (Gde E-250) quality A complete all as specified and directed. |
| 20 | M&L for steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes confirming to IS 1161- 1979 grade St-240 complete all as specified and directed. |
| 21 | M&L for preparation of new or previously untreated steel surfaces of any description, over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete, all as specified & directed by Engineer-in-charge. |
| 22 | M&L for preparation of new or previously untreated steel surfaces of any description, over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete, all as specified & directed by Engineer-in-charge. |
| 23 | Demolition of concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 24 | M&L for PCC (1:2:4) Type B-1, Plain cement concrete with using 20mm graded aggregate in lintels upto 1.5 m clear span, copings, bed plates, cills, steps: seismic and other similar bands, plinth course, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, complete all as specified and as directed. |
| 25 | Demolition of pre-cast cement concrete block walling built in cement mortar complete all as specified and directed by Engineer-in-Charge. |
| 26 | Material and labour for providing precast cement concrete block of PCC (1:3:6) type-C1 in masonry with solid blocks, exceeding 10cm in width & set in cement mortar (1:4) complete all as specified and directed by Engineer-in-Charge. |
| 27 | Taking down cement plaster on brick wall/concrete surfaces etc including racking out joints hacking for key scrubing down with water etc of any thickness including Dado any description complete, all as specified & directed by Engineer-in-charge. |
| 28 | M&L Rendering 10mm thick cement plaster on faces of brick work or concrete surfaces in cement mortar (1:6) in fascia or edging of Chajjas, ceiling and roof projections etc, finished even fair without using extra cement complete all as specified and as directed. |
| 29 | M&L plastering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 mixed with water proofing compound finished even and smooth without using extra cement all as specified and directed. |
| 30 | M&L for prepration of new plastered surfaces of walls and applying two coats of cement base paint over a coat of primer complete all as specified. |
| 31 | M&L for prepration of new plastered surfaces of walls and applying two coats of oil bound distemper over a coat of chalk whiting primer complete all as specified. |
| 32 | Closing bolt holes etc. in old corrugated steel sheets or Aluminium sheeting by sealing with one bitumen and one curved GI washer on either side and 6mm G.I. bolts and nuts, all set in stiff white lead, bolt n exc 25mm in length complete all as specified and directed by Engr in Charge. |
| 33 | Applying evenly a tack coat including cleaning priming surfaces and applying heavy treatment for severe condition using glass fibre base bitumen felt, grade 2 complete all as specified and directed by Engr in Charge. |
| 34 | M&L for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed steel surface by forced application incl taking out old sheets complete all as specified and directed by Engr in Charge. |
| 35 | M&L for preparation of old steel surfaces of any description, over 10cm width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 36 | M&L for preparation of old surfaces of any description, over 10cm width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 37 | M&L for prepration of old decorated plastered surfaces and applying one coat of cement base paint on old plastered surface complete all as specified. |
| 38 | M&L for preparing old plaster surfaces of walls and applying two coats of white wash complete all as specified. Please Enable Macros to View BoQ information |