| 1 | Demolition of cement concrete (unreinforced) in ground floors and pavings not exc 15cm thickness (below or above ground level) complete all as specified and directed by Engr-in-Charge. |
| 2 | M&L for 25mm thick cement concrete type B1, 1:2:4 (20mm graded aggregate) as in floors complete all as specified and directed by Engr-in-Charge. |
| 3 | M&L for 6mm thick Plywood, grade BWR, type BB, fixed with nails to timber frame work (05 No of ply), complete all as specified and directed by Engr-in-Charge. |
| 4 | M&L for 4mm thick Plywood, grade BWR, type BB, fixed with screws to timber frame work in ceiling, complete all as specified and directed by Engr-in-Charge. |
| 5 | Dismantling boarding any description, fixed with any position with nails, complete all as specified and directed by Engr-in-Charge. |
| 6 | M&L for 3mm thick cover fillet of standard hard board, 40mm wide and fixing with screws complete all as specified and directed by Engr-in-Charge. |
| 7 | Dismantling unframed work in fillets, rails, posts, rafters, purlins etc under 40sqcm in section, complete all as specified and directed by Engr-in-Charge. |
| 8 | M&L for second class hard wood in scantling, clean sawn, timber framed and fixed, complete all as specified and directed by Engr-in-Charge. |
| 9 | Dismantling timber scantling 40 sqcm and over in section in any position framed work, complete all as specified and directed by Engr-in-Charge. |
| 10 | Taking down chowkhats with shutters (without taking off shutters from the frame) exc 1.5 sqm but not exc 4.00 sqm each, complete all as specified and directed by Engr-in-Charge. |
| 11 | Taking down chowkhats with shutters (without taking off shutters from the frame) not exc 1.5 sqm each, complete all as specified and directed by Engr-in-Charge. |
| 12 | S&F 2nd class hardwood plain, solid, straight chowkats and frames, wrought framed rebated on the solid, rounded or chamfered put together with glue pinned at joints, complete all as specified and directed by Engr-in-Charge. |
| 13 | S&F 30mm thick 2nd class hardwood, Plain framed, framed, panelled shutter (any number of panels) with panels of timber flat on both sides (feather edged) or of veneered particle board medium density, wood particle board with commercial face veneers fitted to chowkats, complete all as specified and directed by Engr-in-Charge. |
| 14 | S&F 30mm thick 2nd class hardwood, Glazed and skelton shutters, open rebated and prepared to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass etc size of members of shuters as specified in SSR Part-I, Section 8, clause 8.24(a), fittted to chowkats, complete all as specified and directed by Engr-in-Charge. |
| 15 | M&L for preparation of new or previously untreated wooden surfaces of any description, not otherwise described over 10cm width or girth, and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engr-in-Charge. |
| 16 | S&F 125mm butt hinges, mediam weight, cold rolled mild steel and fixed complete all as specified and directed by Engr-in-Charge. |
| 17 | S&F 75mm butt hinges, mediam weight, cold rolled mild steel and fixed complete all as specified and directed by Engr-in-Charge. |
| 18 | S&F 200mm aluminium anodised, barrel tower bolts of extruded section and fixed, complete all as specified and directed by Engr-in-Charge. |
| 19 | S&F 100mm aluminium anodised, barrel tower bolts of extruded section and fixed, complete all as specified and directed by Engr-in-Charge. |
| 20 | S&F 150mm Aluminium handles, cast type, anodised complete all as specified and directed by Engr-in-Charge. |
| 21 | S&F 100mm Aluminium handles, cast type, anodised complete all as specified and directed by Engr-in-Charge. |
| 22 | S&F 250mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, complete all as specified and directed by Engr-in-Charge. |
| 23 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed by Engr-in-Charge. |
| 24 | S&F 0.63mm thick galvanised, corrugated mild steel sheeting with two corrugations side lap,fixed with coach screws and washers in roof, walls etc with grade of zinc coating 275, complete all as specified and directed by Engr-in-Charge. |
| 25 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed by Engr-in-Charge. |
| 26 | Dismantling Plain or corrugated steel sheeting, any gauge, thickness including nanital pattern or similar pattern roof covering, complete all as specified and directed by Engr-in-Charge. |
| 27 | S&F Roof trusses (framed) trussed, purlins, crane gantries rail and fastening and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance piece, cleats etc, Fe 410W (Grade E-250) quality A complete all as specified and directed by Engr-in-Charge. |
| 28 | M&L for preparation of new or previously untreated steel surfaces of any description, not otherwise described over 10cm width or girth, and applying two coats of synthetic enamel paint over a coat of red oxide, zinc crome complete all as specified and directed by Engr-in-Charge. |
| 29 | Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed by Engr-in-Charge. |
| 30 | M&L for Non - skid coloured Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchcomplete all as specified and directed by Engr-in-Charge. |
| 31 | M&L for screed bed or bedding layer of mortar 15mm thick for laying floor finishes in CM 1:6, complete all as specified and directed. |
| 32 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed. |
| 33 | S&F 4mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sqm in each pane complete all as specified and directed. |
| 34 | Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed. |
| 35 | M&L for preparation of old steel surface of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 36 | M&L for PCC 1:3:6 type C2 (40mm graded aggregate) as in surface channel and drains complete all as specified and directed. |
| 37 | M&L for PCC 1:3:6 type C2 (40mm graded aggregate) as in drain walls or plinth wall, retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases) complete all as specified and directed. |
| 38 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for, complete all as specified and directed. |
| 39 | Use and waste flat formwork to faces of walls, drain wall, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter complete all as specified and directed. |
| 40 | M&L for Pre-cast cement concrete block masonry with solid blocks of type C1, 1;:3:6 (20mm graded aggregate) exc. 10 cm in width and setting in mortar 1:6, complete all as specified and directed. |
| 41 | Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, including ashlar facings, dressed stonework and precast concrete articles, complete all as specified and directed. |
| 42 | M&L for Rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 complete all as specified and directed. |
| 43 | M&L for preparing surface of new plastered surface of wall and applying two coats of OBD over a coat of alkali resistance priming paint complete all as specified and directed. |
| 44 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. |
| 45 | M/L for point wiring in casing caping with 1.5sq mm FRLS PVC insulated unsheathed single core multithreaded copper conductor cable 1100 volts grade incl 1.5 Sq mm PVC insulated unsheathed copper conductor cable as earth continuity conductor drown through in and incl casing caping with its accessories pressed steel terminal box incl 3mm thick ISI marked laminated sheet cover for fixing switches/socket/regulators etc for the following: -One light/fan point controlled by one No piano type switch 5 Amps single pole one way |
| 46 | One socket outlet 5/3 pin 6 AMPS controlled by one switch on the same board. |
| 47 | One socket outlet 5/3 pin 6 AMPS controlled by one switch on independent board. |
| 48 | All as per item No 1 above but one 3 pin socket out let 15/16 Amps with three Nos single core unsheathed PVC insulated cable multistranded copper conductor of size 2.5 sq mm for phase, neutral & earth continuity conductor. |
| 49 | S&F Switch Piano Flush button single pole one way 5/6 Amp. |
| 50 | S&F Switch socket combination 2 in 1, 3 pin, 6 and 16 Amp flush type universal |
| 51 | S&F Switch socket combination 2 in 1, 6A flush type |
| 52 | S&F ceiling rose surface bakelite 65mmx50mm 100watt three terminal. |
| 53 | M&L for sub main wiring with two single core PVC insulated of size 6 sqmm FRLS unsheathed copper conductor 1100 volt grade multistandard and incl drawn through and including PVC Casing caping including 6.0 sqmm FRLS copper wire for earth continuity wire and connected of common earth dolly Including taking down old unserviceable sub main wiring and making good of existing surface.Note:- (i)One run of PVC Casing caping, two run of 6 sq mm copper conductor & one run of 6.0 sq mm copper conductor is measured as one unit. |
| 54 | S&F sheet metal enclosure double door for MCB DB single pole and neutral 8 way with 200 Amps rated bus bar 240 volts double door (Metallic) type including taking down old unserviceable MCB DB with MCBs. |
| 55 | S&F MCB SPN 32 Amps 240 volts 'C' series, 10 KA, 50 Hz. Make:- As approved Make of DB |
| 56 | S&F MCB SP 5 to 32 Amps 240 volts 'C' series, 10 KA, 50 Hz including connection in the DB and testing/commissioning. Make:- As approved Make of DB |
| 57 | Supply and fixing LED lights fitting 1x 18W, 4 feet, 220V,AC decorative box type with driver, holder including LED light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. |
| 58 | Supply and fixing LED light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. |
| 59 | Supply and laying or fixing or passing through pipeXLPE insulated, armouredheavy duty electric cable with aluminium conductor, 1100 volts grade of size 16 sqmm 2 core complete including taking out old unserviceable cable all as specified and directed by Engineer in charge. |
| 60 | S&F DWC Pipe 63/50mm size all as specified and directed by Engr-in-Charge. |
| 61 | M&L for Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation of poles, etc. or for laying of cable, pier holes, etc. nexc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft and loose soil |
| 62 | M&L for Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm of hard & dense soil |
| 63 | M&L for Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point of any type of soil |
| 64 | Material and Labour for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground( earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in electrical plate No 3 of SSR Pt I including necessary excavation and earth work PCC (1:3:6) type C-1 with 50 mm thick pre cast RCC ( 1:2:4) type B-1 cover slab framed with 50X30X4 mm MS angle (reinforced with 6 mm dia deformed bar @ 15 cm C/C both ways and suitable handle of 10 mm dia round bar) including providing charcoal or coke and magnesium sulphate in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (medium grade) wire mesh, copper lugs, complete in all respect., GI earth wire protected by 40 mm bore (light grade) galvanized iron pipe and other end connected to the earth bar (test point) made of MS flat (400X32X6 mm) bend in ‘D’ shape and fixed to wall by means of fast nut or bolt grouted in to wall at 1 mtr from plinth height. 4sqmm PVC insulated (colour green) copper conductor single run as earth continuity conductor along with 15 mm PVC conduit grouted in wall or fixed on wall surface to be continued up to main switch board and fix with common earth dolly as directed by EIC . Disposal of soil to a distance not exceeding 50 mtr and necessary testing on completion complete including taking out old unserviceable earthing materials all as specified and as directed. Please Enable Macros to View BoQ information |