| 1 | M&L for light shade vitrified ceramic tiles 8-10mm thick (square/rectangular) area of each tiles exc 0.42 Sqm but not exc 1 Sqm in floors etc set and jointed in neat cement slurry and pointed in epoxy joint filling with 3mm spacer and including 15mm thick screed bed of cement mortar 1:4 laying floor finishes, complete all as specified and directed. |
| 2 | M&L for vitrified ceramic tiles 8-10mm thick (square/rectangular) area of each tiles exc 0.42 Sqm but not exc 1.00 Sqm in floors etc set and jointed in neat cement slurry and pointed in epoxy to match over and including 10mm thick screed bed of cement mortar 1:3 as in skirtings floor finishes, complete all as specified and directed. |
| 3 | M&L for joint free coloured non skid ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.18 but not exceeding 0.38 sqm, in floors etc. set and pointed in epoxy joint filling with 3mm spacer, over 15mm thick screed bed of CM 1:4 complete all as specified and directed. |
| 4 | M&L for epoxy tile joint filling for item No 1&3 using FOSROC or equivalent on floor and walls complete all as specified as per manufacture's instructions and as directed by Engineer-in-Charge. |
| 5 | M&L for glazed ceramic coloured joint free tiles 450x300X7mm/600x300x7mm in vertical surfaces over and including 10mm thick rendering in cement mortar (1:4), set and jointed in neat cement slurry and pointed in coloured cement to match complete all as specified and directed. |
| 6 | M&L for 18-20mm thick granite (of any type) work (table rubbed and polished) stone slab as in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust to match with marble shade over and including cement screed bed 15mm thick in CM (1:6) complete all as specified and directed. |
| 7 | M&L for Granite (of any type) work (table rubbed and polished) for wall lining (veneering to wall) 12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite and including 5mm thick rendering of cement mortar 1:3 as in skirtings floor finishes, complete all as specified and directed |
| 8 | Providing edge moulding to 18-20mm thick granite stone of counters vanities etc. including machine polishing to edge to give high glossy finish etc. complete all as specified and directed. |
| 9 | S&F vitreous china WHB white with flat back of size 550x400mm with bracket including waste coupling and 32mm PVC waste pipe and 15mm bore Pillar taps,cast copper alloy, with capstan heads, chromium plated, fancy type, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and as directed. |
| 10 | S&F in repair vitreous china wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including fixing with trap including Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed. |
| 11 | S&F in repair 8 to 10 Ltr capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets of approved make including fixing of brackets connection to WC with CI brackets and making good disturbed area complete all as specified and directed. |
| 12 | S & F in repair vitreous china urinals, half stall type complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; with PTMT Urinal spreader, grating and Union for discharge pipe complete all as specified and directed. |
| 13 | S&F in repair vitreous china urinal partition white of size 310x700 mm with Urinal partitions slabs terminating about 40cm above floor line, complete all as specified and directed. |
| 14 | S&F in repair brass CP towel Rail 600mm long \\"D\\" type complete all as specified and directed. |
| 15 | S&F 75mm dia PVC (SWR) pipe single socketed, in any length with rubber ring joints, laid in trenches/floors complete all as specified and directed. |
| 16 | S&F 110mm dia PVC (SWR) pipe single socketed, in any length with rubber ring joints, laid in trenches/floor complete all as specified and directed. |
| 17 | S&F 75mm dia PVC (SWR) pipe single socketed, in any length with rubber ring joints, laid in wall including clamps complete all as specified and directed. |
| 18 | S&F 110mm dia PVC (SWR) pipe single socketed, in any length with rubber ring joints, laid in wall including clamps complete all as specified and directed. |
| 19 | S&F 100mm Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed. |
| 20 | S&F 75mm stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed. |
| 21 | S&F PVC (SWR) bend any radius 110mm bore with access door complete all as specified and directed. |
| 22 | M&L for 75mm PVC (SWR) multi floor trap with grating including jointing with solvent cement complete all as specified and directed. |
| 23 | S&F 75mm PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed. |
| 24 | S&F 110mm PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed. |
| 25 | S&F 75mm PVC (SWR) vent cowl complete all as specified and directed. |
| 26 | S&F 75mm dia PVC (SWR) bends with access door complete all as specified and directed. |
| 27 | S&F 600x450mm looking mirror of selected quality glass mounted on 6mm thick of commercial plywood and PVC moulding frame fancy type complete all as specified and directed. |
| 28 | Dismantling structural steel work in cluding doors, gates but excluding framed truss etc complete all as specified and directed. |
| 29 | Demolition of brick work in cement mortar complete all as specified and directed. |
| 30 | M&L for 15mm thick rendering in cement mortar (1:6) on fair faces of brick work or concrete surfaces, finished even and fair without using extra cement complete all as specified and directed. |
| 31 | M&L for water proofing for sunken slabs including all materials as per the stages described below, complete all as specified and as directed. (a) Remove all dust, oil, dirt, latiance and other containments, loose particles from concrete surface.(b) Chamfering the floor wall junctions with cement mortar 1:4 admixed with NitoBond SBr or equivalent @ 1 litre per 50 Kg bag of cement. (c) Annular space of out let/spout pipes shall be packed and sealed using Conbextra GP2 or equivalent mixed water and filling as per manufacturers specifications.(d) Carrying out ponding for minimum of 48 hours. (e) Injection grouting of all leaking spot and honey combs with cementious pressure grouting with 40psi pump using Cebex 100 or equivalent @225 gms mixed to 50 Kg bag of cement incl joints packing using polymer modified mortar. (f) Providing and applying water proof coating using fosroc Nitoproof 600 or equivalent, over dry surfaces to achieve 1.5mm thick with 02 coats with interval period of 6 hours over the surface using spray/ squngee/ roller/ brush. Water proofing coating shall have the elongation of 500-700% (ASTM D412-90), tear resistance of 21Kn/m (ATMD624-00) and tensile strength of >1.9 N/mm2. Termination to be done on wall extending the coating to min 300mm height above the finished floor level as per vendor recommendation. Laying 200gsm non-woven geo textile membrane over Nitoproof 600 coating with overlap sealed. |
| 32 | Demolition of cement concrete (un-reinforced) in ground floors and pavings n.exc 15cm thick (above or below GL) complete all as specified and directed. |
| 33 | M&L for plain cement concrete (1:4:8) type D2 (using 40 mm graded brick aggregate) as in sunken floor complete all as specified and directed. |
| 34 | M&L for 50mm thick PCC (1:2:4) type B1 (Using 20mm graded stone aggregate) for sub base of sunken portion complete all as specified and directed. |
| 35 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 36 | S&F solid PVC door frame of size 50mm x 47mm made out of 5mm ivory colour PVC sheet reinforced with M.S. square tube, S&F in opening as per specification and drawing complete all as specified and directed. |
| 37 | S&F factory made Solid PVC moulded door shutters 28 to 30 mm thick (stile) with wood free EPS, with 2,4 or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front Face & 2mm Plain colour PVC sheet on back face, S&F in frame at site as per specification & drawing all as specified. |
| 38 | M&L for formwork to sides of and soffits of lintels and beams, etc.;and similar work flat rough finished cement concrete complete all as specified and directed. |
| 39 | M&L for RCC Nominal mix 1:1.5:3 (20mm graded crushed stoneaggregate) as in beams, cantilevers, bressumm etc, lintels over 1.5m span complete all as specified and directed. |
| 40 | M&L for mild steel TMT bars 10mm dia and over, cut to length bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 41 | M&L for mild steel TMT bars 5 mm dia & over upto 10 mm as in stirrups, cut to length bent to shape required, including cranking, bending for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 42 | M&L for use and waste formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick for fair finished surfaces (Horizontal or sloping) complete all as specified and directed. |
| 43 | M&L for RCC nominal mix type A-1 1:1.5:3 (using graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like for complete all as specified and directed. |
| 44 | M&L for precast cement concrete block masonry Type C1, 1:3:6 (20 mm graded stone aggregate) with solid blocks exc 10 cm in width and setting in cement mortar 1:6 in foundation load bearing wall complete all as specified and directed. |
| 45 | M&L for 10mm thick rendering in cement mortar (1:6) on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed. |
| 46 | S&F 100 mm long mild steel butt hinges medium weight complete all as specified and directed. |
| 47 | S&F aluminum anodized barrel tower bolt 200mm long of extruded section complete all as specified and directed. |
| 48 | S&F aluminum anodized sliding door bolt 200mm long with hasp and staples (bolt type) and fixing clips of sheet cast of extruded section and fixing bolts and sliding bolts of extruded section complete all as specified and directed. |
| 49 | S&F aluminum bow handle \\"D\\" type anodized 150mm long complete all as specified and directed. |
| 50 | M&L for surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed. |
| 51 | M&L for hardcore(broken stone or boulders) of gauge not exc. 63mm deposited, spread and levelled in layers not exc. 15cm thick watered and rammed to a true surface. complete all as specified and directed. |
| 52 | M&L for 75 mm thick PCC 1:4:8 Type C-2 using 40 mm graded stone aggregate complete all as specified and directed. |
| 53 | M&L for chequered colour cement concrete tiles 30x30cmx 25mm thick set jointed grey and pigment and pointed in neat cement slurry in floors/steps including screed bed or bedding layer of morter 15mm thick in cm 1:4 complete all as specified and directed. |
| 54 | M&L for cement concrete type B- 1, 1:2:4 (20mm graded stone aggregate) for coping or chamferred on edges complete all as specified and directed. |
| 55 | Excavation in trenches n.exc 1.5m and n.exc 1.5m in depth for foundation and getting out in soft/ loose soil complete all as specified and directed. |
| 56 | Returning filling in soft/loose soil including spreading leveling watering and wall ramming in layers n/exc 25 cm thick complete all as specified and directed. |
| 57 | Removing excavated soil exc.250m but n.exc 500m and depositing where directed by Engineer-in -Charge. |
| 58 | M&L for plain cement concrete type D-2 1:4:8 (using 40mm graded stone aggregate) as in foundation complete all as specified and directed. |
| 59 | M&L for 10mm thick rendering in cement mortar (1:4) on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed. |
| 60 | M&L for three coats of white wash to newly plastered surfaces of walls complete all as specified and directed. |
| 61 | Taking down carefully existig copper / alumnium point wiring for light / fan / bell / socket 5/15 Amp points complete with fitting and fixtures such as switches, sockets, c/ rosess, holders and bracket fittings with battens / conduits / wires,T/L fittings and making good the disturbed surfaces of walls and roofs etc.and to match with existing colour complete all as specified and directed. |
| 62 | M&L for light / fan point wiring with 1.5 Sqmm PVC insulated sheathed FRLS multistranded single core copper conductor cable in PVC concealed conduit rigid non metalic (ISI marked) fixed concealed on wall/ roof except beam, column and RCC roof including chases cutting incl suitable size/ cap of sunken box for modular switch and socket and modular white cover plate, flush metal box etc incl 1.5 Sqmm PVC insulated copper conductor as earth continuity wire for one light point controlled by one switch and making good disturbed surfaces of walls, floors etc complete all as specified and as directed. |
| 63 | All as per item No. 62 here in before but for one 3 pin 5 Amp socket outlet point controlled by one switch on Independent board complete all as specified and as directed. |
| 64 | All as per item No. 62 here in before but for one 3 pin 5 Amp socket outlet point controlled by one switch on same board complete all as specified and as directed. |
| 65 | All as per item No. 62 here in before but for one bell/buzzer point controlled by one push button on the same board with other switches or independent with cables 1.5 sq.mm size complete all as specified and as directed. |
| 66 | All as per item No.62 here-in-before but one 15 Amps socket outlet point controlled by one single pole switch one way and wiring with 2.5 Sqmm PVC insulated, stranded, unsheated copper conductor on independednt board with continuous earth wire of size 2.5 Sqmm green colours PVC insulated, unsheathed, stranded copper conductor cable complete all as specified and as directed. |
| 67 | All as per item No. 62 here-in-before but one 15 Amps socket outlet point controlled by one single pole switch one way and wiring with 4.0 Sqmm PVC insulated, stranded, unsheated copper conductor on independednt board with continuous earth wire of size 4.0 Sqmm green colours PVC insulated, unsheathed, stranded copper conductor cable complete all as specified and as directed. |
| 68 | S&F switch modular type 6 amps, 1 module single pole one way duly ISI marked, complete all as specified and directed. Make: Legrand Cat Part No. 5734 00 or equivalent make as per the approved list of manufactures. |
| 69 | S&F switch modular type 16/20 amps, 1 module single pole one way duly ISI marked, complete all as specified and directed. Make: Legrand Cat Part No. 5734 10 or equivalent make as per the approved list of manufactures. |
| 70 | S&F socket outlet modular type 6A - 2 in 1,with shutter, 2 module, duly ISI marked, complete all as specified and directed. Make: Legrand Cat Part No. 5734 24 or equivalent make as per the approved list of manufactures. |
| 71 | S&F socket outlet modular type 6/16A, 3 pin combined, 2 module, duly ISI marked, complete all as specified and directed. Make: Legrand Cat Part No. 5734 71 or equivalent make as per the approved list of manufactures. |
| 72 | S&F bell push modular type 6 amps, 1 module single pole one way duly ISI marked, complete all as specified and directed. Make: Legrand Cat Part No. 5736 13 or equivalent make as per the approved list of manufactures. |
| 73 | S&F ceiling rose surface type, 240 volts, 50 Hz, 6A, Pilot 3 plate, white in colour, bakelite 65 x 50mm, 3 terminals duly ISI marked complete all as specified and directed. |
| 74 | S&F rotary stepped type electronic fan regulator for ceiling fan 1200/1400mm size, 240 volts, 6 Amps, 2 module, 120W, white in colour, duly ISI marked complete all as specified and directed.Make: Legrand Cat Part No. 5734 63 or equivalent make as per the approved list of manufactures. |
| 75 | S&F LED light fitting 1 x 20 Watt, 120 Lumen/Watt, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.Make: Philips Cat Part No. BN100C LED40S-6500 PSU L120 GR S4 or equivalent make as per the approved list of manufactures. |
| 76 | S&F LED building security light fitting 60 Watt, 120 Lumen/Watt, 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/ 66 protection complete all as specified and directed.Make: Philips Cat Part No. BRP030 P LED35 CW SLR GR PSU SPD or equivalent make as per the approved list of manufactures. |
| 77 | S&F LED light fitting mirror type with high out put diffuser 2 feet 10 Watt, 120 Lumen/Watt, 240 V, AC decorative type with driver holder and LED lamp including connecting up with tree core flexible copper conductor cable of suitable size complete all as specified and directed.Make: Luker Cat part no. LMCL10 or equivalent make as per the approved list of manufactures. |
| 78 | S&F LED luminaire 600 mm x 600 mm,35/36 watt, 120 Lumen/Watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed.Make: Philips Cat Part No. RC370B LED36S-6500 G6 L60W60 PSU OD V3 or equivalent make as per the approved list of manufactures. |
| 79 | S&F round shape 15 watt, 120 Lumen/Watt, 220 volts AC surface type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as per specified and directed. Make: Philips Cat Part No. SM296C LED15S-6500 PSU WH or equivalent make as per the approved list of manufactures. |
| 80 | S&F in replacement LED lights fitting suspended type 1x 40 W, 220V, AC decorative box type,120 lumen/watt with driver, holder and high quality materials and design extruded aluminium housing enhances safety, IP-20 rating, driver efficiency 90%,high quality PC diffuser reliable and robust housing structure including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceilingrose complete all as specified and as directed. Make: Philips Cat No SP780 H LED44S-6500 PSU W5L224 OD S1 WH or equivalent make as per the approved list of manufactures. |
| 81 | S&F in replacement of Factory made three phase and neutral sheet steel made out of CRCA 1.2 mm thick, powder coated double door distribution board 4 way, dust and vermin proof, fitted with two cover, one screwed cover for incoming MCBs and outgoing MCB the second for protection of MCBs fitted with colour AL bus bar of capacity 200 Amps, neutral link, earth bar and din rail. suitable for use on 415V, 50Hz supply, partly immersed in wall and making good disturbed surfaces with matching colour, complete all as specified and directed.Make: L&T Cat Part No. DBTPN004DDS or equivalent make as per the approved list of manufactures. |
| 82 | S&F MCCB TPN, 160 Amps, 415 volts,rated service short circuit breaking capacity Ics= Icu at 415V ,36 KA duly ISI marked with enclosure, complete with connection testing and commissioning complete all as specified and directed.Make: L&T Cat Part No. CM98065OONO & CM91003OOOO or equivalent make as per the approved list of manufactures. |
| 83 | S&F MCB TPN 40 To 100 AMP, 240 volts, \\"C\\" series, 10KA duly ISI marked, in MCB DB, complete with connection testing and commissioning complete all as specified and directed.Make: L&T Cat Part No. BB40400C to BB40630C or equivalent make as per the approved list of manufactures. |
| 84 | S&F 240V, 10KA 'C' curve miniature circuit breaker (MCB) SP and 6-32 Amps current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed.Make: L&T Cat Part No. BB10060C to BB10040C or equivalent make as per the approved list of manufactures. |
| 85 | M&L for sub main wiring with four single core 4x10 Sqmm FRLS insulated and sheathed stranded copper conductor alongwith earth wire 10 Sqmm drawn in FRLS rigid conduit connected to main board including taking down old down complete all as specified and directed. (Four runs cable and one number earth wire and suitable FRLS conduit shall measured together as unit length). |
| 86 | S&F in replacement of ceiling fans, complete with blades, down rods, accessories 230V, 1200mm sweep, with min air delivery 210 CFM with service value 6.00 BEE, five star rated with brushless direct current (BLDC) including provision of PVC flexible copper cable of size 23/00.0076 three core from ceiling rose to exhaust fan max 1.5 mtr for giving connection complete all as specified and directed. Note : Old Ceiling fans to be deposited at AGE E/M (NW) store yard.Make: Orient Model Ecotech Neu BLDC 5 star or equivalent make as per the approved list of manufactures. |
| 87 | S&F in replacement down rod madeout of , suitably threaded and holed, made out of 15 mm dia GI tubes heavy grade, duly painted, 4' long, suitable for ceiling fans any type, any make, any size complete all as specified and directed. |
| 88 | S&F exhaust fan plastic body heavy duty with louvers complete of sweep size 250mm, 1200 RPM, single phase, with bolts, nuts and washers, size of the bolt 15 cm long 12mm dia embedded in the wall including suitable size of cutting/opening the wall for fixing and provision of PVC flexible copper cable of size 23/00.0076 three core from ceiling rose to exhaust fan max 1.5 mtr for giving connection complete all as specified and directed.Make: Havells Cat Part No. Ventil Air-DX white or equivalent make as per the approved list of manufactures. |
| 89 | S&F wall mounting fan (Air Circulator), metallic body, heavy duty 300 mm sweep including all fixing arrangements on walls/ steel surfaces complete all as specified and directed.Make: Havells Model No. D’Zire Hs or equivalent make as per the approved list of manufactures. |
| 90 | Earthing complete with galvanized steel plate elecrode of size 60 cm x 60cm x 6.0 mm thick burried directly in ground vertically to a depth not less than 2.5 mtr below the ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level. Earth plate surrounded by 15mm thick packed alternative layers of charcoal dust and comman salt, earth lead GI wire of 4mm dia (8 SWG) by means of bolts, nuts, check nuts and washers of galvanised iron with thimbles. The other end of GI earth wire is connected to main switch board and protected by light grade GI pipe of 15 mm bore. Provision of 20mm bore light grade GI pipe for watering including GI funnel and wire mesh. Pipe shall be provided vertically upto top level of earth pit and then taken horrizontally to the earth pit. Cement concrete chamber of PCC (1:3:6) type C-2 using 40 mm graded stone aggregate.The chamber shall be constructed one metre away from edge of earth pit. 50 mm thick pre cast cover of cement conrete (1:2:4) type B-1 using 20 mm graded stone aggregate and MS angle iron 50 x 50 x 6 mm frame including two coats of painting over a red oxide to exposed steel surfaces. Excavation in soft/ loose soil, returning filling and removal of surplus soil to a distance of 50 mm as directed and shown in Electrical Plate No- 3 of SSR Part-1 (2009). |
| 91 | S&F in replacement of factory made three phase and neutral sheet steel made out of CRCA 1.2 mm thick, powder coated double door distribution board 6 way, dust and vermin proof, fitted with two cover, one screwed cover for incoming MCCBs and outgoing MCB the second for protection of MCBs fitted with colour cu bus bar of capacity 200 Amps, neutral link, earth bar and din rail. suitable for use on 415V, including MCCB 160 Amps - 01 No, 50Hz supply, partly immersed in wall and making good distrubbed surfaces with matching colour, complete all as specified and directed.Make: L&T Cat Part No. DBVTH006DD or equivalent make as per the approved list of manufactures. |
| 92 | S&F in repair SPN Enclosure with two pin and earth plug and socket complete with one SP MCB, 20 Amps having breaking capacity 10 kA, including taking down old unserviceable earth plug, complete all as specified and directed.Make: L&T Cat Part No. DBMPS320SD or equivalent make as per the approved list of manufactures. |
| 93 | S&F on wall/ concealed on wall, 25 mm dia, high pressure CPVC pipes SDR-13.5 & pipes SDR 11 fittings including all necessary fittings, solvents, complete all as specified and directed. |
| 94 | S&F on wall/ concealed on wall, 20 mm dia, high pressure CPVC pipes SDR-13.5 & pipes SDR 11 fittings including all necessary fittings, solvents, complete all as specified and directed. |
| 95 | S&F 20 mm size chromium plated fancy type bib taps, quarter turn with flange and aerator, short body, cast copper alloy with crutch or butterfly hanhdle, screwed for GI/ CPVC pipe, complete all as specified and as directed.Make: CERA Cat Part No. F2004151 or equivalent make as per the approved list of manufactures. |
| 96 | S&F bib cock CP quarter turn with flange and areator, fancy type short body cast copper alloy with crutch or butterfly handle screwed for GI/ CPVC pipe of size 15 mm complete all as specified and as directed.Make: Model No F1099151 of Cera or equivalent make as per the approved list of manufactures. |
| 97 | S&F in repair 15mm size Chromium Platede cast copper alloy angle valve, half turn with flange, for fixing with CPVC pipe, complete all as specified and as directed.Make: CERA Cat Part No. F2004201 or equivalent make as per the approved list of manufactures. |
| 98 | S&F concealed push stop cock regular body,Quarter turn with adjustable wall flange chromium plated with CP cup fancy type of size 20mm or any other make from the approved list of manufacturers.Make : Model No: F8010108 of Cera or equivalent make as per the approved list of manufactures. |
| 99 | S&F in repair health faucet ABS body with wall hook and 1 metre SS braided rubber hose pipe , complete all as specified and directed.Make : Cera Model No: F8030102 or equivalent make as per the approved list of manufactures. |
| 100 | M&L for cutting chases on walls, floors etc not exceeding 10cm girth and making good the disturbed surface to match with the existing surface after removing the existing concealed pipe/laying new pipe ,complete all as specified and directed by Engineer-in-Charge. |
| 101 | S&F 2000 litres capacity Rotational moulded polyethylene water storage tanks (cylindrical, vertical with closed top), hoisted & fixed in position, including taking down old unserviceable one complete all as specified and as directed. |
| 102 | S&F in repair 25 mm dia CPVC Ball valve suitable for CPVC pipe including necessary fittings, complete all as specified and directed. Please Enable Macros to View BoQ information |