| 1 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 3.5 in superstructure above plinth level up to floor V level. |
| 2 | Cement mortar 1:4 (1 cement :4 coarse sand) |
| 3 | Extra for half brick masonry in superstructure, above floor V level for every four floors or part thereof by mechanical means. |
| 4 | Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry |
| 5 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : |
| 6 | 300x16 mm |
| 7 | 250x16 mm |
| 8 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. |
| 9 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 10 | a) 200x10 mm |
| 11 | Providing and fixing aluminium handles ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 12 | a)100 mm |
| 13 | b) 75 mm |
| 14 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. |
| 15 | a) Twin rubber stopper |
| 16 | Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality for aluminium door, with necessary screws etc. complete as per direction of Engineer-in-charge. |
| 17 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, levelling system and rubber mallet for placing the tiles gently and easily. Double charge vitrified tile polished finish of size |
| 18 | Size of Tile 600x600 mm |
| 19 | 12 mm cement plaster of mix : |
| 20 | 1:6 (1 cement: 6 fine sand) |
| 21 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : |
| 22 | a) Water thinnable cement primer. |
| 23 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and of required shade and colour complete to give and even shade. |
| 24 | New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 25 | Finishing walls with Acrylic Smooth exterior paint of required shade : |
| 26 | New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 27 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 28 | Two or more coats on new work. |
| 29 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 30 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 31 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: |
| 32 | Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm). |
| 33 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) : |
| 34 | For fixed portion |
| 35 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 36 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). |
| 37 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 38 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): |
| 39 | With float glass panes of 4.0 mm thickness (weight not less than 10 kg/sqm) |
| 40 | With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 41 | Providing and fixing aluminium handle of outer dia 100mm with SS screws etc. complete as per direction of Engineer-in-charge |
| 42 | Powder coated minimum thickness 50 micron aluminium |
| 43 | Repairs to the existing wooden doors/windows by removing and refixing the same after attending necessary repairs etc. with necessary screws, nails, hinges etc. wherever required complete to make it working condition (Each door/window irrespective of size will be measured for payment. Cost of Hinges, handles and other accessories, if any used, will be paid separately). |
| 44 | Carting out of building rubbish / malba / similar unserviceable, dismantled, excavated or waste materials by mechanical means, through private carrier including lifting, loading, transporting, unloading to municipal dumping ground beyond 50 m initial lead, or in any other compound as decided by the Engineer-in-charge, for all leads including all lifts involved. |
| 45 | Dismantling of existing aluminium partitions, doors and other frames including proper numbering, stacking and placing all the materials at the required place in the building as directed by the Engineer-in-charge. (Area of partition being dismantled shall be measured for payment) |
| 46 | Fixing of aluminium partitions and doors after sorting required sections as per the drawing with available material of aluminium sections, particle board, glass panels and snap on beading including fixed with new rawl plugs and screws, neoprene gasket or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions at top, bottom and sides with required PVC/Neoprene felt etc., aluminium sections shall be cleaned properly, and shall be mitred and jointed mechanically wherever required all complete as per the architectural drawings and the directions of the Engineer-in-charge. (The available material as above on as is where is basis in stacked condition will be supplied by the department at no cost. The materials shall be shifted from the building store to the workplace. Finished area of partition shall be measured for payment) |
| 47 | Removal of corroded MS windows with frame of size 2.95 x 1.25 m by arranging welding machine at site including removing of the existing glass panes, making good the wall surfaces with cement mortar for fixing of new ventilators and stacking the dismantled material at the ground/basement floor etc., complete, all as directed by Engineer-in- charge. The work is to be executed in 6th floor of the building and nothing extra shall be paid on any account. |
| 48 | Rebate for taking away the unusable steel windows including the transportation, loading etc., complete Please Enable Macros to View BoQ information |
| 49 | Rebate for taking away the unusable steel windows including the transportation, loading etc., complete Please Enable Macros to View BoQ information |