| 1 | CONSTRUCTION OF BIOLOGY LAB AT HIGHER SECONDARY SCHOOL AGHAR JITTO DISTRICT REASI PM SHRI SAMAGRA 2025-56. |
| 2 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil : |
| 3 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 4 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1.1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size) |
| 5 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 6 | Reinforced cement concrete work in walls (any thickness) including attached pilasters,buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering,finishing and reinforcement.1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 7 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand) |
| 8 | Extra for brick work with common burnt clay bricks/ cement concrete bricks in superstructure above plinth level upto floor five level |
| 9 | Half brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 in foundations and plinth including curing in Cement mortar 1:4 ( 1 cement : 4 coarse sand) |
| 10 | Extra for half Brick masonry in superstructure above plinth level upto floor V level. |
| 11 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°,landings, balconies, shelves, chajjas, lintels, bands, plain window sills,stair cases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with.1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 12 | Steel reinforcement for R.C.C. work including straightening , cutting, bending, placing in position and binding all complete upto plinth level & above plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 13 | Centering and shuttering including strutting, propping etc. and removal of form work for: Foundations, footings, bases for columns. |
| 14 | Centring and Shuttering including strutting, propping etc and removal of form work for Lintels, beams, plinth beams, girders,bressumers and centilevers. |
| 15 | Centring and Shuttering including strutting, propping etc and removal of form work for Columns, pillars, piers, abutments, posts and struts. |
| 16 | Centring and shuttering including strutting , propping etc. and removal of form work for Suspended floors, roofs, landing, balconies and access plate form |
| 17 | Centring and Shuttering including strutting, propping etc and removal of form work for Edges of Slabs and Break in floors and walls (Under 20 cms wide) |
| 18 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Riveted and bolted |
| 19 | 6mm cement plaster to ceiling of mix 1:3 ( 1 cement :3 fine sand). |
| 20 | 12 mm cement plaster of mix 1:6 ( 1 cement : 6 coarse sand) |
| 21 | 15mm Cement plaster on the rough side of single or half brick wall of mix 1 : 6 ( 1 cement : 6 fine sand) |
| 22 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): Sal wood |
| 23 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows including lSI marked M.S. pressed Butt hinges bright finished of required size with necessary screws excluding panelling which will be paid for separately,all complete as per direction of engineer- in charge). 35mm Thick Second Class Kail Wood |
| 24 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. commercial ply both side |
| 25 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. 35mm thick second class Kail wood |
| 26 | Providing and fixing hardware fixtures (Aluminium) ISI marked anodised (Anodic coating) not less than grade AC 10 as per IS-1868 |
| 27 | Sliding door bolts (250 x 16mm) |
| 28 | Tower bolt200x10mm |
| 29 | Tower bolt150x10mm |
| 30 | Tower bolt100x10mm |
| 31 | Handle 125mm |
| 32 | Handle 100mm |
| 33 | Twin rubber stopper |
| 34 | Providing and fixing bright finished brass hard drawn hooks and eyes; 100 mm |
| 35 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to lS: 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 60x60cm. |
| 36 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. complete job as per direction of engineer-in-charge |
| 37 | Carriage of materials by mechanical transport inculding loading / unloading and stacking complete. |
| 38 | Sand lead up to 20 kms |
| 39 | Stone aggregate below 40 mm lead up to 20 kms. |
| 40 | Stone agg. above 40 lead up to 20 kms. |
| 41 | Bricks lead up to 50 Kms. |
| 42 | CONSTRUCTION OF PHYSICS LAB AT HIGHER SECONDARY SCHOOL AGHAR JITTO DISTRICT REASI (ON FIRST FLOOR OF BIOLOGY LAB) PM SHRI SAMAGRA 2025-56 |
| 43 | Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. |
| 44 | 70% Ordinary Rock |
| 45 | 30% All kind of Soil |
| 46 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil : |
| 47 | 70% Ordinary Rock |
| 48 | 30% All kind of Soil |
| 49 | Providing and laying 75mm thick compacted bed of dry brick aggregate40mm thick nominal size including spreading, well rammed, consolidated and grouted with fine sand including finishing smooth etc. complete as per direction of Engineer-in-charge |
| 50 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 51 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 52 | Providing and laying damp-proof Course 50 mm thick with cement concrete 1:2:4 (1 cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and curing complete |
| 53 | Reinforced cement concrete work in walls (any thickness) including attached pilasters,buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering,finishing and reinforcement.1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 54 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand) |
| 55 | Extra for brick work with common burnt clay bricks/ cement concrete bricks in superstructure above plinth level upto floor five level |
| 56 | Half brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 in foundations and plinth including curing in Cement mortar 1:4 ( 1 cement : 4 coarse sand) |
| 57 | Extra for half Brick masonry in superstructure above plinth level upto floor V level. |
| 58 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°,landings, balconies, shelves, chajjas, lintels, bands, plain window sills,stair cases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with.1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 59 | Steel reinforcement for R.C.C. work including straightening , cutting, bending, placing in position and binding all complete upto plinth level & above plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 60 | Centering and shuttering including strutting, propping etc. and removal of form work for: Foundations, footings, bases for columns |
| 61 | Centering and shuttering including strutting, propping etc. and removal of form work for Retaining walls, return walls, walls (any thickness) including attached pilasters buttresses, plinth and string course fillets, kerbs and steps etc. |
| 62 | Centring and Shuttering including strutting, propping etc and removal of form work for Lintels, beams, plinth beams, girders,bressumers and centilevers. |
| 63 | Centring and Shuttering including strutting, propping etc and removal of form work for Columns, pillars, piers, abutments, posts and struts. |
| 64 | Centring and shuttering including strutting , propping etc. and removal of form work for Suspended floors, roofs, landing, balconies and access plate form |
| 65 | Centring and Shuttering including strutting, propping etc and removal of form work for Edges of Slabs and Break in floors and walls (Under 20 cms wide) |
| 66 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Riveted and bolted |
| 67 | 6mm cement plaster to ceiling of mix 1:3 ( 1 cement :3 fine sand). |
| 68 | 12 mm cement plaster of mix 1:6 ( 1 cement : 6 coarse sand) |
| 69 | 15mm Cement plaster on the rough side of single or half brick wall of mix 1 : 6 ( 1 cement : 6 fine sand) |
| 70 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): Sal wood |
| 71 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows including lSI marked M.S. pressed Butt hinges bright finished of required size with necessary screws excluding panelling which will be paid for separately,all complete as per direction of engineer- in charge). 35mm Thick Second Class Kail Wood |
| 72 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. commercial ply both side |
| 73 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. 35mm thick second class Kail wood |
| 74 | Providing and fixing hardware fixtures (Aluminium) ISI marked anodised (Anodic coating) not less than grade AC 10 as per IS-1868 |
| 75 | Sliding door bolts (250 x 16mm) |
| 76 | Tower bolt200x10mm |
| 77 | Tower bolt150x10mm |
| 78 | Tower bolt100x10mm |
| 79 | Handle 125mm |
| 80 | Handle 100mm |
| 81 | Twin rubber stopper |
| 82 | Providing and fixing bright finished brass hard drawn hooks and eyes; 100 mm |
| 83 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to lS: 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 60x60cm. |
| 84 | Applying priming coat with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 85 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade. Two or more coats on new work. |
| 86 | Distempering with 1st quality acrylic distemper (ready mixed)having VOC content less than 50 gms/litre,two or more coats on new work of approved manufacturer, of required shade and colour complete as per manufacturer’s specifications |
| 87 | Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm) |
| 88 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete. |
| 89 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. Layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering lead upto 50m and lift upto 1.5m. |
| 90 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. complete job as per direction of engineer-in-charge |
| 91 | Providing and fixing of ceiling fan all complete including accessories etc. (1200 mm size and 3 blades) of make Crompton, Havells, Bajaj or Polycab. |
| 92 | Providing and fixing on wall face unplasticised - Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion Single socketed pipes 110 mm diameter. |
| 93 | Providing and fixing on wall face un-plasticized - PVC moulded fittings/accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 110 mm bend |
| 94 | Providing and fixing 1st quality ceramic glazed tiles conforming to IS :·13753 of minimum thickness 5 mm of approved make like NITCO, ORIENT, SOMANY KAJARIA, or equivalent make in all colour, shades except begundy, bottle green, black of any size as approved by Eningeerin-Charge in skirting, risers of steps and dados over 12mm thick bed of Cement Mortar 1:3 ( 1 cement: 3 coarsesand) and jointing wtih grey cement slurry@ 3.3 kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 95 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Size 600x450x200 mm |
| 96 | Providing and fixing p.v.c waste pipe for sink or wash basin including p.v.c waste fitting complete. |
| 97 | Providing and fixing G.l. pipes complete with G.l. fittings and clamps, including cutting and making good the walls etc: Concealed pipe including painting with anti-corrosive bitumastic paint, cutting chases and making good the wall15 mm dia. nominal bore |
| 98 | Providing and fixing G.l. pipes complete with G.l. fittings and clamps, including cutting and making good the walls etc: Concealed pipe including painting with anti-corrosive bitumastic paint, cutting chases and making good the wall 20 mm dia. nominal bore |
| 99 | Providing and fixing G.l. pipes complete with G.l. fittings and clamps, including cutting and making good the walls etc.: 15 mm nominal bore (External work) |
| 100 | Providing and fixing G.l. pipes complete with G.l. fittings and clamps, including cutting and making good the walls etc.: 20 mm dia. nominal bore (External work) |
| 101 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 15mm nominal bore |
| 102 | Providing and fixing ball valve (brass) of approved quality complete. 15 mm nominal bore |
| 103 | Providing and fixing ball valve (brass) of approved quality complete. 20 mm nominal bore |
| 104 | Providing and fixing 100 mm sand cast iron grating for gully, floor or Nahani trap. |
| 105 | Providing and placing on terrace (at all floor levels) polyethylene water tank with cover and suitable locking arrangement and making hole for inlet, outlet and overflow pipe but without fitting and base support for tank |
| 106 | Constructing soak pit 1.20x1.20x1.20m filled with birckbats including S.W. drain pipe 100 mm diameter and 1.20m long complete as per standard design. |
| 107 | Lettering with black Japan paint of approved brand and per letter |
| 108 | Providing and Laying in position PVC drainage pipe including all fittings complete.110mm dia |
| 109 | Carriage of materials by mechanical transport inculding loading / unloading and stacking complete. |
| 110 | Sand lead up to 20 kms |
| 111 | Stone aggregate below 40 mm lead up to 20 kms. |
| 112 | Stone agg. above 40 lead up to 20 kms. |
| 113 | Bricks lead up to 50 Kms. Please Enable Macros to View BoQ information |