| 1 | DSR Item No. 1.10Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 2 | Group-C |
| 3 | DSR Item No. 1.15Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel /PVC conduit including dismantling as required. |
| 4 | Group C |
| 5 | DSR Item No. 1.17Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 6 | 3 x 1.5 sq. mm |
| 7 | 3 x 2.5 sq. mm |
| 8 | DSR Item No.1.21Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 9 | DSR item No.1.23Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. |
| 10 | 5/6 amps switch |
| 11 | 3 Pin 5/6 A. socket outlet |
| 12 | 15/16 amps switch |
| 13 | 6 Pin 15/16 A. socket outlet |
| 14 | DSR item No.1.24Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 15 | 5/6 amps switch |
| 16 | 3 Pin 5/6 A. socket outlet |
| 17 | 15/16 amps switch |
| 18 | 6 Pin 15/16 A. socket outlet |
| 19 | DSR item No.1.25Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 20 | DSR Item No.1.38 Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. |
| 21 | DSR Item No. 2.2 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections Ics=100% Icu and Operational Voltage 690V etc. as required. |
| 22 | 100 A, 16 KA,TPMCCB |
| 23 | 400 A, 35 KA,TPMCCB |
| 24 | DSR Item No. 2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 25 | Single pole |
| 26 | Triple pole and neutral |
| 27 | Supply & erection of fresh air fan high speed motor with copper wound 10” sweep with louver and plastic body complete with high speed motor, blades, epoxy powder coated of Havells make Ventiliar DX White / Orient make Ventilator / Crompton make Brisk Air/ Bajaj make 70049 250mm sweep only. (As per Complete Item No. 11 of the DNIT) |
| 28 | DSR ITEM NO. 9.2Brush Less Direct Current (BLDC) MotorSupply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, (As per Complete Item No. 12 of the DNIT) |
| 29 | 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 30 | 1400mm, service value ≥ 6.0 CM/Min/Watt, air delivery 245 CM/Min (Minimum) |
| 31 | Supply & erection of Exhaust Fan (heavy duty motor with copper wound metallic body) following size complete with motor, metallic blades, double ball bearing with minimum power consumption, (As per Complete Item No. 13 of the DNIT) |
| 32 | Size 12” Sweep 900 RPM with louver of Havells make Turbo Force SP / Orient make Industrial Heavy Duty / Crompton make EXHD 300-6-1/ Bajaj make Supreme PLUS/ Usha make Turbo HDEF only. |
| 33 | Supply and erection of 5/7/9 Watt. LED lamp suitable for existing E-27, E-40 holder. The LED lamp should be of Philips / Osram / Bajaj / Wipro / Twinkle make only. The job includes the cost of all other petty material etc. as required to complete the job to the entire satisfaction of Engineer-in-charge. The color and wattage of lamp should be as selected by the occupant. |
| 34 | S/I/T/C of recessed type 4/ 5 Watt LED step light fitting. The job includes the cost of cutting of existing stone/ marble and repairing the same to original finish. The fitting should be of make May fair MF BHF 805 5W/ Bajaj make RAZOR BLSGV 5 Watt LED WH or its equivalent model of Philps/ Havells/ Wipro/ Crompton/ Surya/ K-Lite/ Panasonic make only. (As per Complete Item No. 15 of the DNIT) |
| 35 | S/E of ding dong type electronic bell including carriage, testing with suitable size of nuts / bolts and other petty material etc. as required to complete the job to the entire satisfaction of EIC. The bell should be of Cona/ Anchor/ Gold Medal/ Havells make only. |
| 36 | S/E of 18Watt./20Watt. 4’ long LED tube rod made of polycarbonate material should be installed in existing LED fitting base only. The make of LED tube rod should be same as that of existing LED fitting. (As per Complete Item No. 17 of the DNIT) |
| 37 | Supply, Erection, Testing and commissioning of the following accessories after dismantling the burnt out/ defective accessories with the help of ladder if required which shall be arranged by the firm at his own cost. (As per Complete Item No. 18 of the DNIT) |
| 38 | S/E of Electronic Driver suitable for existing 2’x2’/1’x4’ LED panel type fitting. The Driver should be same make of existing fitting. |
| 39 | Supply, Erection, Testing and commissioning of the following items in existing LED fittings installed on pole upto 12 Mtr. Long / wall in place of burnt out / defective material with the help of hydraulic ladder / Crain with bucket which shall be arranged by the firm at his own cost. (As per Complete Item No. 19 of the DNIT) |
| 40 | S/E of Electronic Driver suitable for existing 90/100 Watt. LED fitting. The Driver should be same make of existing fitting. |
| 41 | S/E of Electronic Driver suitable for existing 240 Watt. LED fitting. The Driver should be same make of existing fitting. |
| 42 | Supply and Erection of electronic step type socket type fan regulator in existing B.L. Sheet including making connection and petty material reqd. to complete the job. The fan regulator should be of Anchor Panta / Havells Reo/ Gold Medal Essenza make only |
| 43 | S/E of PVC Gang Box of Anchor Panta make or its equivalent make including carriage, erection with suitable size of nuts / bolts and other petty material etc. as required to complete the job to the entire satisfaction of EIC. |
| 44 | 0+1 (Single Switch) |
| 45 | 2+2 (2 Switch 2 Socket) |
| 46 | 1+1 (P Switch P Socket) |
| 47 | 1+1 (Lt Switch Lt Socket) |
| 48 | DSR Item No. 8.16.3LED Flood Light, powder coated pressure die cast aluminum (System lumen efficacy ≥120 and <135 lm/Watt)Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, (As per Complete Item No. 22 of the DNIT) |
| 49 | 100 Watt Please Enable Macros to View BoQ information |