| 1 | Dismantling floor, hearth or wall tiling including cement mortar bedding removing serviceable tiles to store and rubbish off the premises. |
| 2 | M&L for non skid ceramic coloured tiles 1st quality 7 to 8mm thick, (square/ rectangular), area of each tile exceeding 0.06sqm, but not exceeding 0.11sqm as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, laid over and including 15mm thick screed bed or bedding layer in cement mortar 1:6, complete all as specified and as directed by the Engineer-in-Charge.Note: Colour and shade of tiles shall be approved by AGE(I) and contractor shall not have any claim whatsoever on this account. |
| 3 | M&L for Vitrified Ceramic tiles (Dark shade/ Double charged/ Ultra charged) 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 Sqm but not exceeding 1.00 sqm, as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured, laid over and including 15mm thick screed bed or bedding layer in cement mortar 1:6, complete all as specified and as directed by the Engineer-in-Charge.Note: Colour and shade of tiles shall be approved by AGE(I) and contractor shall not have any claim whatsoever on this account. |
| 4 | M&L for Vitrified Ceramic tiles (Dark shade/ Double charged/ Ultra charged) 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 Sqm but not exceeding 1.00 sqm, as in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface over 10mm thick cement plaster in cement mortar 1:4, complete all as specified and as directed by the Engineer-in-Charge.Note: Colour and shade of tiles shall be approved by AGE(I) and contractor shall not have any claim whatsoever on this account. |
| 5 | M&L for glazed ceramic tiles, coloured, of size 350mm x 250mm/450 mm x 350mm, thickness not less than 7mm as in vertical surfaces such as skirting/dado etc, set and jointed in neat cement slurry and pointed with white cement mixed with pigment to match the shade of tile, fixed over and including 10mm thick rendering (bedding layer) on brick/concrete surface in cement mortor 1:4, complete all as specified and as directed by the Engineer-in-Charge.Note: Colour and shade of tiles shall be approved by AGE(I) and contractor shall not have any claim whatsoever on this account. |
| 6 | Dismantling of stone slab/tile of any description or thickness in floor, apron etc laid bedded and pionted in any mortar. |
| 7 | M&L 20mm Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms, and like over 15mm thick screed bed in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. |
| 8 | S&F in repairs for wooden laminated flooring in strips of size 120cm long and 20cm wide and 6-8mm thick, fixed with PVC sheet and cushion including fillets/cornices, laid over 12mm thick BWR plywood including dismantling, complete all as specified and directed. |
| 9 | Rounding/moulding to edges of Kota stone slabs, marble stone, granite stone slabs one edge, such as in steps, cooking platform , and other similar situations etc |
| 10 | Taking down cement plastering on stone wall/brick wall etc including racking out of joints hacking for key scrubbing down with water etc. |
| 11 | M&L 15mm thick rendering on fair faces of wall in CM 1:6 on brick/concrete surface and finishing the surface even and smooth with out using extra cement. |
| 12 | Demolition of brickwork or stone/boulder masonry, build in cement mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articles, complete all as specified and directed by Engineer-in-Charge. |
| 13 | M&L for Brick work with sub class `B' bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6, complete all as specified and directed by the Engineer-in-Charge. |
| 14 | Material and labour for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper over 3mm thick wall care putty, complete all as specified. |
| 15 | M&L for preparing old plastered or unplastered surfaces of walls and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over surfaces complete all as specified and directed. |
| 16 | Taking up or down 15 mm bore steel tubing and connection including cleaning for re-fixing or removal to store complete all as specifed and directed. |
| 17 | M&L 25mm outer dia 3-layer PP-R P o l y p r o p y l e n e random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded p o l y p r o p y l e n e random fittings fixed complete to walls, ceilings or in floors etc complete all as specified and directed. |
| 18 | Taking up or down 20 mm bore steel tubing and connection including cleaning for re-fixing or removal to store complete all as specifed and directed. |
| 19 | M&L 32mm outer dia 3-layer PP-R P o l y p r o p y l e n e random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded p o l y p r o p y l e n e random fittings fixed complete to walls, ceilings or in floors etc.complete all as specified and directed. |
| 20 | Cutting chases, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edges of shelves , for water tubing etc and making good, cutting exc 10cm girth but not exc 20cm girth in brick/stone walls. |
| 21 | Dismantiling of water tanks of capacity n. exc 250 & exc 500 ltrs including all necessary fittings complete. |
| 22 | S&F 500 ltrs PVC rotational moulded polyethylene water storage tanks triple layer made (cylindrical vertical with closed top ) hoisted and fixed in position all as specified in SSR part-I |
| 23 | S&F 32 mm dia PPP-R gate valves (Brass inserted) as per requirment of the site complete all as specified. |
| 24 | S&F Vitreous china wash hand basin (vanity) long pattern type of size 78cm x 48cm including all fittings with decorative cabinet with door/shutter and 2 Nos. drawers, complete all as specifed and directed. |
| 25 | S&F Vitreous China Water closet one piece of \\" size (WxPxH) 365x650x760mm white with 'P' or 'S' trap, Model- LAUREN of Make - Somany Bathware, or of equivalent item of Make- JAQUAR, ESSCO,PARKO, ORIENT etc as approved by AGE(I) |
| 26 | S&F in repairs sink made of stainless steel 1mm thick kitchen or laboratary with plugs, washers and waste pipe: including bedding in cement mortor to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 495mm x 420 mm and bowl size 410mm x 330mm, complete all as specified and directed by Engineer-in-Charge. |
| 27 | S&F 600x450 bevelled edged looking mirror 2mm thick of selected quality glass, mounted on 4 mm thick PVC sheet and with aluminnium frame work fitted with chromium plated brass screws and cup washers including taking old one. |
| 28 | S&F swivel shower, fancy type, chromium plated for fixing with 15mm pipe with shower arm 15mm size ,195 mm long with bend of 45 degree with flange of any colour fixed in repairs. |
| 29 | Supply and fix 15mm dia brass CP mixer fancy type chromium plated for mixing hot and cold water screwed down for iron pipe . |
| 30 | S&F in repair 15mm dia stop valves/angle valve chromium plated, fancy type with long shank and cup screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions as specified . |
| 31 | S&F in repair Soap dish, chromium plated any type and fixed with screw, complete all as specified. |
| 32 | S&F health faucet (ABS body) mild steel chromium plated suitable for 15mm dia with 1.25mtr long flexible tube and ABS wall hook including making connection and fixed in position, complete all specified and directed by Engineer-in-Charge. |
| 33 | S&F 15mm PVC connection 450mm long with PTMT nuts of superior quality complete all as specified. |
| 34 | Supply and fixed in repair sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railing 60cm long complete all as specified. |
| 35 | S&F in repair tubular towel rail aluminium anodised 20mm dia, D type, 60 cm long with brackets complete all as specified |
| 36 | S&F in repairs harrison rail/curtain rails, mild steel chromium plated with fixing brackets, stops, rollers etc as specfied and directed. |
| 37 | Taking down chowkats or frames with shutters (without taking off shutter from the frame) of any description alongwith fittings n.exc 1.5sqm each. |
| 38 | Taking down chowkats or frames with shutters (without taking off shutter from the frame) of any description alongwith fittings exc 1.5sqm n.exc 4 sqm each. |
| 39 | S&F PVC Door frames of size 50 mm x 47 mm made of 5 mm single side pre-lam colour PVC sheet and edges will be painted to match with pre lam sheet reinforced with MS square tube, suppling and fixing in opening as per specification and drawing. |
| 40 | S&F Factory made Solid PVC Moulded Door Shutter with particle board core, 28 to 30 mm thick (stiles), with 2,4, or 6 raised panel design with 2 mm thick Moulded PVC sheet on the front face & 2mm Plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & Drawing |
| 41 | S&F 2nd class hard wood Plain, solid, straight chowkats and frames, wrought , framed rebated on the solid , rounded or chamfered put together with glue pinned at joints, supplied and fixed. |
| 42 | S&F 35 mm thick 2nd class hard wood Plain framed, panelled shutters (any number of panels), with panel of timber flat on both sides (feather edged) or 12 mm thick BWP of veneered particle board medium density wood commercial face veneers fixed to chowkats. |
| 43 | S&F 2nd class hardwood glazed and skelton DOOR shutters 35 mm thick divided into squares open rebated and prepared to receive glass, gauge etc edges of framing plain, chamfered, rounded fitted with mitred beads for securing glass etc, size of members as specified in SSR Pt I section 8 clause 8.20 (b) supplied and fitted to chowkats with plain, chamfered or rounded mitred and rebated bars any numbers. |
| 44 | S&F Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and avgerage width of aperature 1.18 mm fixed with tinned tacks, or galvanised wire staples. |
| 45 | S&F aluminium alloy anodised sliding door bolts 250 mm long with hasp, staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts of extruded sections complete all as specified. |
| 46 | S&F aluminium anodised barrel tower bolts of extruded section 150mm long all as specified |
| 47 | S&F Butt hinges, medium weight cold rolled 100mm size ISI marked all as specified. |
| 48 | S&F Extruded aluminium alloy handles fabricated type anodised 150mm size all as specified |
| 49 | S&F in position powder coated anodised aluminium three track window (minimum thickness of powder coating 50 micron) of extruded modular and anodised approved colour, shade and finish having aluminium section of Jindal and equivalent approved make and size of frame/ rails 92mm x 31.75mm x 1.9mm thick (weight not less than 1.174 Kg/RM). The shutter comprising of bearing bottom and top of size 48mm x 20mm x 1.30mm thick (weihgt not less than 0.539 Kg/Rm), interlocking section of size 50mm x 29mm x 1.28mm thick (weight not less than 0.594 Kg/Rm) and hand sides of 50mm x 20mm x 1.5mm thick (weight not less than 0.571 Kg/Rm) including aluminium deco grill and fixing of 5mm thick clear black plain glass of Saint Gobain or equivalent make in two shutter and stainless steel wire cloth 0.36mm nominal dia of wire, average width of aperture 1.4mm, fixed in one shutter including approved quality neoprene gasket, bottom roller, fixtures, fastenings and accessories like PVC taflon bearing of MITI or approved make, 6\\" star locks, stainless stell screws, joining cleat for fixing etc complete all as specified and directed by Engr-in-charge.Note:- The rate is inclusive of cost of 5mm thick sheet glass and stainless steel wire cloth. |
| 50 | Dismantling of drain pipes of size 100mm bore or below (Salt glazed ware/AC pipe/reinforced concrete pipe/CI/PVC pipe ) set in cement mortar including concrete bed & haunching (if required) and removing away complete from site, complete all as specified and as directed by the Engineer-in-Charge. |
| 51 | S&F 110mm PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to walls complete |
| 52 | S&F 75mm PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to walls complete |
| 53 | S&F 110mm PVC (SWR) bends with or without access door complete all as specified and directed. |
| 54 | S&F 75mm PVC (SWR) bends with or without access door complete all as specified and directed. |
| 55 | M&L 75mm PVC (SWR) floor trap , plain with grating including jointing with solvent cement complete all as spd and directed |
| 56 | S&F 18/19mm thick veneered decorative plywood, grade 1, with decorative face veneers on both faces, fixed with screws to timber frame work as in shelves/ kitchen cupboard/almirah shutter with dishrack, crockery unit, wire baskets, grain trolley and drawer unit for modular kitchen complete all as specfied and directed. |
| 57 | S&F 1.5mm thick decorative laminate, type 1, of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturers instructions, complete all as specfied and directed. |
| 58 | Dismantling boarding/ false ceiling of any description, fixed in any position with nails, complete all as specified and directed by the Engineer-in-Charge. |
| 59 | S&F GI frame work size of grid 605 x 605 mm for seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/intermediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45mm suspended from sofit at approx 900 mm centre to centre with GI cleat and steel expansion fasterner with and including ceiling section (not exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips acress the intermediate channel at 457mm centre to cnetre including hangers 6mm dia.GI (upto 1200mm length) adjusting level fixed tp roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm ling and expansion hold fasterner 12.5mm dia 40mm long including 8mm thick non asbestos fibre cement building boards fixed or laid/inserted to timber/GI/ Aluminium frame work, complete all as specified and directed by Engineer-in-Charge. |
| 60 | S&F 2nd class soft wood boarding, 15mm thick, as in wall panelling, plain one side and edges tongued and grooved or rebated, fixed with nails in any situation including french polishing on surface of any description width or girth including cleaning and preparing the surface including a coat of wood filler on new works with two or more coat upto satification of Engr-In-Charge. |
| 61 | M & L for applying two coat of synthetic enamelled paint over one coat of pink primer including preparation of new wooden surfaces of any description not otherwise described over 10 CM girth or width all as directed by the Engineer in charge |
| 62 | Taking down carefully copper/aluminium point wiring (light, fan, light & power socket) complete with fittings and fixtures such as switches,ceiling rose ,pendents, regulators, socket, lamp holders brackets,bulk head fitting, etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and also making good distrubed surfaces of wall,floors etc, complete all as specified and directed by the Engineer-in-Charge. |
| 63 | M&L for point wiring using cable (1.5 Sq mm for phase and neutral and 1.5 sq mm earthing) wiring with FRLSH cable PVC insulated (red for phase and black for neutral) unsheathed, multi stranded copper conductor 1100 volt grade in and including not less than 2mm thick PVC conduit with all accessories and earth continuity connected to common earth duly accommodate modular box surface/ flush type with modular white cover plate with frame for mounting fittings such as switches, sockets, fan regulators etc complete all as specified and directed by the Engineer-in-Charge for the following:- |
| 64 | One light /fan/bell point controlled by one No, one way 5 Amps switch. complete all as specified and as directed by the Engineer-in-Charge. |
| 65 | One bell point controlled by one No. bell push, complete all as specified and as directed by the Engineer-in-Charge. |
| 66 | One multi pin socket outlet, 5/6 Amp, controlled by one No. one way switch on same board, complete all as specified and as directed by the Engineer-in-Charge. |
| 67 | One multi pin socket outlet, 5/6 Amp, controlled by one No. one way switch on independent board, complete all as specified and as directed by the Engineer-in-Charge. |
| 68 | All as per serial item No 63 here-in-before ,but for one socket out let 15 Amp on the independent board with 2.5 sqmm copper conductor multistranded PVC insulated and unsheathed electric cable 1100 volts (ISI MARKED) including PVC insulated and unsheathed electric cable 1100 volts, 2.5 sqmm copper stranded conductor as continuous earth wire connected to common earth dolly, complete all as specified and as directed by the Engineer-in-Charge. |
| 69 | S & F modular switch piano button flush type, single pole one way 6 amps complete all as specified as directed. |
| 70 | S & F modular socket 6A, 2/3 pin combined 2 module complete all as specified as directed. |
| 71 | S & F modular switch piano button flush type, single pole one way 16 amps complete all as specified as directed. |
| 72 | S & F modular socket 6A/16A, 2/3 pin combined 2 module complete all as specified as directed. |
| 73 | S&F ceiling rose surface bakelite 3 terminals 65 x 50mm complete all as specified and as directed by Engineer-in-Charge. |
| 74 | S&F Fan step modular regulator, 2 module, complete all as specified and directed. |
| 75 | S&F modular bell push 6A, 1 module one way, complete all as specified and directed. |
| 76 | S & F White cover plate with frame, 2 module, complete all as specified. |
| 77 | S & F White cover plate with frame, 3 module, complete all as specified. |
| 78 | S & F White cover plate with frame, 4 module, complete all as specified. |
| 79 | S & F White cover plate with frame, 8 module, complete all as specified. |
| 80 | S & F Metal flush box 1/2 module, complete all as specified. |
| 81 | S & F Metal flush box 3 module, complete all as specified. |
| 82 | S & F Metal flush box 4 module, complete all as specified. |
| 83 | S & F Metal flush box 8 module, complete all as specified. |
| 84 | S&F in repairs electric ding dong bell, 230V AC, single pole, complete all as specified and directed. |
| 85 | S&F LED Lights fitting 20 watt, 220V, AC Decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. |
| 86 | S&F replacement for angular type lamp holder PVC polycarbonate type with back plate including 7W lamp, complete all as specified. |
| 87 | Supply and fixing sheet metal enclosure for MCB's, double door SPN 230 volts, 12 way with 200 amps rated bus bar and making good to disturbed surfaces of floors, walls etc including taking down the old unserviceable DBs, complete all as directed. |
| 88 | S&F MCB SPN, 40-63 Amps, 240 volts, 10 kA rupturing capacity, 'C' curve type, including taking down old existing, complete all as specified and as directed by the Engineer-in-Charge. |
| 89 | S&F MCB SP, 6-32 Amps, 240 volts, 10 kA rupturing capacity, 'C' curve type, including taking down old existing, complete all as specified and as directed by the Engineer-in-Charge. |
| 90 | M&L for Sub main wiring with two single core FRLS, PVC insulated, stranded and unsheathed copper conductor cable of size 10 sqmm and drawing through and including non metallic PVC conduit concealed in wall including earth continuity conductor of size 10 Sqmm PVC insulated unsheathed copper conductor (multi-stranded) and connected to earth dolly to be drawn in concealed PVC conduit including connecting to main board complete all as specified and directed by Engineer in charge. |
| 91 | Note :- An amount of Rs. Rs 14,497.00 on account of credit schdule for Sch 'A' Part-II Shall be deducted from the total amount of BOQ to arrive at the contract sum. Please Enable Macros to View BoQ information |