| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: Garrison Engineer (AF) Gorakhpur Name of Work: SPECIAL REPAIR TO BLDG NO- 29 (ORS MD ACCN) AT NCC ENCLAVE GORAKHPUR MIL STN UNDER GE(AF) GORAKHPUR. Contract No.: GE(AF)/GKP/E-106 OF 2025-26 File No. 9429/E8 Serial Page No.15 Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Item Code / Make Quantity Units Estimated Rate inRs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e. DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit, if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes inRs. P TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Taking down cement or lime plaster any description on brick or stone walls etc including recking out joints hacking for key scrubbing down with waters. complete all as specified as directed. |
| 3 | S&F Rendering 15mm thick in cement mortar 1:6 on faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified as directed. |
| 4 | M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick masonry or concrete surfaces of walls, chajja, fins facia etc upto 3 storie height mixed with water proofing compound (ISI marked) @ 3% by weight of cement or as per manufacturer’s instructions, finished even & smooth without using extra cement complete all as specified. Note 1: - Supply only water proofing compound shall be measured and paid for separately. 2. Cost of scafolding for rendering is incuded in this item. 2: Rendering will be done in two layer. 1st layer will be 10-12 mm thick and 2nd layer will be 3-5 mm thick. |
| 5 | M&L rendering 5mm thick 1:3 CM on fair face of concrete surface on ceiling finished even and smooth without using extra cement |
| 6 | Supply only liquid water proofing compound complete all as specified and directed. |
| 7 | M&L for Preparation of new plaster surfaces of wall and applying two coats of distemper oil emultion over a coat of primer with roller complete all as specified as directed. |
| 8 | M&L for preparation of newly plastered surface and applying three coat of white wash on ceiling surface incl complete all as specified as directed. |
| 9 | M&L for old preparation of surface and two coat of white wash on old ceiling surface incl complete all as specified as directed. |
| 10 | Preparation of old plaster surfaces of wall including complete removal of existing treatment and applying two coats of distemper oil emultion complete all as specified as directed. |
| 11 | Preparation of new plaster surfaces of wall and applying two coats of cement base paint over a coat of primer complete all as specified as directed. |
| 12 | Demolition of cement concrete (unreinforced) of any description and any position not otherwise specifically provided complete all as specified as directed. |
| 13 | M&L 75mm thick PCC type B-1, (1:2:4) using 20mm graded stone aggregate in Sub base, hard standing , plinth protection etc finished the surface even & smooth without using extra cement complete all as specified as directed. |
| 14 | M&L 75mm thick PCC type D-2, (1:4:8) using 40 mm graded stone aggregate in Sub base, etc complete all as specified as directed. |
| 15 | M&L for Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified as directed. |
| 16 | M & L for PCC 1:2:4 type B1 (Using 20 mm graded aggr) as in coping and similar works incl necessary from work complete all as specified as directed. |
| 17 | M&L PCC 1:3:6 type C-1 (using 20mm graded stone aggregate ) in surface chanel and drain complete all as specified as directed. |
| 18 | Demolition of brickwork built in cement mortar or cement lime mortar complete all as specified as directed. |
| 19 | M&L Brick work with sub class B bricks straight or curved on plan exc 6m mean radius built in CM 1:4 complete all as specified as directed. |
| 20 | S&F steel water tubing `medium grade’ galvanized 15 mm bore with all medium grade fittings (such as bends, elbows, tees, short pieces, connectors, backnuts, diminishing pieces, caps, plugs and unions, etc.) and fixed complete to walls and ceiling concealed and joints fixed with adhesive including taking down of water tubing complete all as specified & directed. |
| 21 | S&F steel water tubing `medium grade’ galvanized 20 mm bore with all medium grade fittings (such as bends, elbows, tees, short pieces, connectors, backnuts, diminishing pieces, caps, plugs and unions, etc.) and fixed complete to walls and ceiling concealed and joints fixed with adhesive including taking down of water tubing complete all as specified & directed. |
| 22 | S&F in repair 500 ltr capacity rotantional moulded triple layer polythylene water storage tanks white color (cylindrical vertical with closed top ) and suitable size of MS tasla with locking system hoisted and fixed in position all as specified in SSR Part I including 20mm dia Ball valves standard of PTMT any colour high pressure with epoxy coated aluminium rod & high density plastic ball screwed,for iron pipe and fixed.(Minimum weight 20mm - 210gms complete all as specified and directed. |
| 23 | S&F in repair 20 mm dia gun - metal globe or gate valves with iron wheel head ,screwed both ends for iron pipe and fixed |
| 24 | S&F in repair vitreous chaina squating pan orissa pattern size 580X 440mm white with intregal foot rest complete including lime concrete(excl flushing cistern and flush pipe) but connecting to flushing pipe, anti-symphonage pipe etc complete fixed in repair complete all as specified as directed. |
| 25 | S&F in repairs 10 Litre capacity PVC low level flushing cistern with ball valve and handle/push button 32mm dia PVC flush pipe including taking down unserviceable cistern complete all as specified and directed. |
| 26 | S&F in repair vitreous china wash basin white flat back size 550x400mm excluding taps ,including waste cupling,waste pipe , complete all as specified and directed. |
| 27 | S&F in repairs for 15 mm bore pillar taps CP fancy type screwed down high pressure with long shanks and fly nuts screwed for iron pipe Hot or Cold with long screwed and fixed complete all specified and directed. |
| 28 | S&F in repair brass chromium plated concealed valve of 15 mm bore complete all as specified and directed. |
| 29 | S&F in repair brass chromium plated angle stop cock, of 15 mm bore complete all as specified and directed. |
| 30 | S&Fin repair CP bib taps fancy type CP alloy with crutch or butterfly handle screwed for iron pipe or for brass ferrule, of fixed 15mm dia. complete all specified and directed. |
| 31 | S&F in repairs CP Grating doom 125 mm dia with waste hole complete all specified and directed. |
| 32 | S&F in repairs CP Grating doom 100 mm dia with waste hole complete all as specified as directed. |
| 33 | S&F in repairs 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all specified and directed. |
| 34 | S&F in repair Stainless steel kitchen plate rack of size 600x900x250 of best quality ISI marked made out of 1.0 mm thick Stainless steel fixed with Nails complete all as specified and directed. |
| 35 | S&Fin repairs sink with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all specified and directed. |
| 36 | S&F in repairs Towel Rail 450mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 170gms) complete all specified and directed. |
| 37 | S&F in repair brass chromium plated shower rose fixing with 15mm bore pipe size 125mm long complete all as specified. |
| 38 | S&F in repair Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all specified and directed. |
| 39 | S&F in repairs PVC connections 450mm long, 15 mm size with brass chromium plated nuts at ends complete fixed in repair complete all as specified and directed. |
| 40 | S& F in repair Soap dish, any type, fixed toplugs with chromium plated brass screws complete all specified and directed. |
| 41 | S&F in repairs PVC (SWR) gully trap 125/110 mm,setting and jointing with solvent cement complete all specified and directed. |
| 42 | M&L in repair 75mm dia PVC (SWR) floor trap, plane with grating including jointing with solvent cement complete all specified and directed. |
| 43 | S&F in repairs PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed |
| 44 | S&F in repairs 75mm PVC (SWR) bends anyradius complete all specified and directed. |
| 45 | S&F in repairs PVC waste pipe 40mm dia for sink ISI marked complete all specified and directed. |
| 46 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all specified and directed. |
| 47 | S&F 110mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all specified and directed. |
| 48 | S&F 110mm PVC (SWR) bends any radius complete all specified and directed. |
| 49 | S &F in repair 100 mm Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, in any position complete all specified and directed. |
| 50 | S &F in repair 75 mm Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, in any position complete all specified and directed. |
| 51 | S& F in Repair 100 mm cost iron Bends (any radius) with duck's foot or heel rest complete all specified and directed. |
| 52 | S& F in Repair 75 mm cost iron Bends (any radius) with duck's foot or heel rest complete all specified and directed. |
| 53 | S& F in Repair 75 mm cost iron Branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches . |
| 54 | S& F in Repair 100 mm cost iron Branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches complete all specified and directed. |
| 55 | Material and labour for treating the sunken floor with preparing surfaces by brushing with wire brushes for removing caked mud etc sweeping with brooms and finally fanning the cleaned surface with funny bags to remove all loose dirt etc, applying consisting of the following operation:-(a) 10mm thick plaster/screed bed in cement mortar 1:3 complete mixed with liquid water proofing compound as per manufactures instructions complete all as specified & directed (Note - WPC shall be measured and paid separately).(b) Cleaning floor surface by wire brush brooming & removing dust & shall be painted with a coat of bituminous primer conforming to IS : 3384-1986 @ 0.3 Ltr per Sqm uniformily complete all as specified & directed. (c) After primer the entire roof surface applying tack coat of hot blown bitumen grade 85/25 grade conforming to 702-1988 @ 1.2 Kg per sqm over primer.(d) Over hot bitumen laying polymeric water proofing membrance conisting of 90 to 100 micron thick center core of HMHDPE Film with standard weight not less than 3 Kg per Sqm over entire area laid with 100mm side lap/end lap on prepared surfaces as per manufacture's technical instruction & sealed complete all as specified & directed.(e) Again the entire floor surface applying tack coat of hot blown bitumen grade 85/25 grade conforming to IS 702 @ 1.2 Kg per sqm. |
| 56 | S&F in repair 40 mm tube galvanised iron light grade cut to required size as per site requirement to be placed in sunken portion of toilet/bathroom and taking out old pipe. |
| 57 | Material and labour PCC E-2, 1:5:10, using 40mm graded aggregate for filling of sunken portion including demolition of existing material/Treatment, all as specified and directed by Engineer In Charge. |
| 58 | Demolition of brick tiles flat or edges pointed in any type of mortar complete all as specified and directed. |
| 59 | Dismantling/Demolition /striping out of existing roof treatment (terfelt and roof plaster etc) including PCC padding of any discription and any thikness including backing and removal the debris complite all asspecified and directed. |
| 60 | M&L for 40 mm thick PCC roof padding 1:2:4 type B-0, 12.5 mm graded stone aggregate in floors , finished smooth .complete as specified and directed. |
| 61 | M&L for 10 mm thick screed bed or bedding layer of mortar in CM 1:3, using Liquid Water Proofing Compound as per manufacturer's instruction, laid in roof finisshed even and smoooth without using extra cement (WPC shall be paid separately) complete all specified and directed. |
| 62 | M&L for Water proofing treatment on \\"approachable / accessible roof\\" surface (Horizontal & Vertical surfaces) in following sequence through manufacturer / authorized applicator of the manufacturer all as specified and directed complete(i) Applying approved bituminous based primer conforming to IS : 3384-1995 @ 0.3kg/Sqm to be applied on top surface of prepared surface till the surface is properly impregnated.(ii) Laying APP (Atactic polypropylene Polymer Modified preffabricated membrane) waterr proofing membrane of weight not less than 3 kg/sqm with minimum 100mm side overlap along the length from downward to upward completely sealed with torch application/hot blown lamps.(iii) Applying two coats of bituminious based bitumen primer @ 0.3kg/sqm and spreading corse sand on primer to obatined rought sufrace which facililate make a bond between membrane and screed bed complete all as specified and as directed. |
| 63 | M&L for 300mm x 300mm x 7-9mm thick size roof cool tile to reduce room temperaature, slip resistance, ocean blue in colour laid in cement mortar 1:6 and pointing in CM 1:3 over 15mm thick screed bed complete all as specified and directed. |
| 64 | M&L PCC in roof kerbs of mud stops, rounded or chamfered on edges and base of Over head tank type B1 (1:2:4) using 20 mm graded aggregate complete all as specified and directed. |
| 65 | M&L for demolition of stone slabs and tiles of any description or thickness in floors, aprons etc.laid bedded and pointed in any mortar all as specified. |
| 66 | M&L machine cut kota stone slab flooring 20-25mm thick over 20mm thick (1:6) cement screed bad laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete. |
| 67 | Ditto but as in riser of steps, skirting, dado and pillar but prepolished kota stone laid over 15mm tick cement plaster in CM 1:4.complete all specified and directed. |
| 68 | S&F 20 mm Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, win dow-cills, cooking plat forms and like 20 mm cement mortar (1:4) including point ing in white cement (1:2) us ing marble dust with admix ture of pigment to match with shade of granite complete all specified and directed. |
| 69 | M&L Rounding to edges of stone slabs one edge, such as in steps,cooking platform, and other similar situations complete all specified and directed. |
| 70 | Demolition of concrete of any description and in any position not other wise specifically provided for cement concrete reinforced including roof padding, Rcc Tank etc complete all as specified and directed. |
| 71 | M&L for RCC 1:2:4 type B0 using 12.5mm graded stone aggregate as in chajja, fins, fascia and similar suspended work in bldg upto 6M height incl use and waste of necessary formwork and scaffolding required complete all specified and directed. |
| 72 | M&L for providing pre-cast RCC lintel ,shelves and cooking plateform etc type B-1 ,1:2:4 using 20 mm graded stone aggregate and set in cement mortar in 1:4 for door and window opening including use and waste of form work complete all specified and directed. |
| 73 | Mild steel TMT bars 6 mm to 8 mm dia., cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips quality confirming to Fe-410-S 0r Fe-410-O complete all specified and directed. |
| 74 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all specified and directed. |
| 75 | S&F Non - skid coloured Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over 15 mm thick screed bed in cm 1:6 etc complete all specified and directed. |
| 76 | Ditto but as in skirting over 10 mm thick cement morter in 1:4 complete all specified and directed. |
| 77 | S&F joint free non skid coloured ceramic tiles 7 to 8mm thick(square / rectangular ) area of each tile n.exceeding 0.11 sqm , in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over 15 mm thick screed bed in cm 1:6 etc complete all specified and directed. |
| 78 | S&F Glazed ceramic coloured tiles 450x300x7mm thick in skirting dados risers to steps etc set and jointed in neat cement slurry and pointed in coloured cement to match tiles over 15mm thick rcement plaster in cm 1:4 complete all as specified as directed. |
| 79 | Taking down chowkats or frame not exc 1.5 sqm with shutter (with out taking of shutter from frame) all as specified and remooving from site complete all as specified as directed. |
| 80 | Taking down chowkats or frame exc 1.5sqm and n.exe 4 sqmwith shutter (with out taking of shutter from frame) all as specified and remooving from site complete all as specified as directed. |
| 81 | Taking down shutters of any description n exc 1 Sqm each complete all as specified as directed. |
| 82 | S & F Pressed steel frames for doors of size 105 x 60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc. complete as specification all as specified and directed. |
| 83 | S & F Pressed steel frames for doors of size 125 x 60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc. complete all as specified as directed. |
| 84 | M&L for PCC 1:3:6 type C1 as in hold fast blocksand filling in pressed steel frame and fasning of hold fast incl. Necessary form work complete all as specified as directed. |
| 85 | S/F 35mm thick factory made plain framed, panelled shutter(two panel) with lock rail and panel of 9mm B.W.P commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS: 1003(part I), kilm seasoned and chemically pressure treated complete all as specified as directed. |
| 86 | S&F factory made second class hardwood glazed and skeleton door shutters 35mm thick, open rebated and prepared to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass, etc complete all as specified and directed. |
| 87 | S& F in repair Prelaminated particle board 18/19mm thick, exterior grade, prelaminated one side with decorative choice lasmination & other side balancing white lamination in pelmet boxes,cup board shutters etc, rebated or flat edged fixed in repairs complete all as specified as directed. |
| 88 | S&F factory made solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplying and fixing in opening as per specification & drawing. |
| 89 | S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail. Panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, supplying & fixing in the frame at site as per specification & Drg. |
| 90 | S & F powder coated anodised aluminium (sliding/hanging type) windows/ventilator with three track bottom track size 92 X 29.5 X 1.5 mm thick, side & top track frame size 92 X 29.5 X 1.5 mm thick and shutter aluminium anodised 39 X 20 X 1.5 mm thick incl necessary aluminium fittings like jointing cleats, glazing cleats, rubber packing, anodised aluminium snap beading, screws etc with 5mm thick tinted/plain glass in panels and stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40 mm incl all fittings & fixture complete all as specified and directed. |
| 91 | S&F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm fixed with tinned tacks or stainless steel wire staples.complete all as specified and directed. |
| 92 | S&F 18 mm thick PVC ply of grade1 quality make as approved by GE of both side prelem fixed with screws, solvent cement/adhesive to make cupboard shutter sides top and bottom, shelves inside the cabinet and shutter or drawer complete all as specified and dfirected. |
| 93 | M&L made PVC shelf/partition of required size consisting of panel of 18 mm thick PVC ply make as approved by GE and supporting the shelf/partition and shall provide with PVC runners in thee sides of shelf size 18x18mm as per required length. The front side of the edge visible in the front of the shelf/partition to be edgelipped by 18mm with 1 mm thick PVC sheet of density 600 kg/Cum density manufactured by an ISO-9000 certified company, using solvent cement etc complete all as specified and directed. |
| 94 | S&F 75 mm size L/Z type stainless hinges fixed screws openable at 110 degree for cabinet shutter complete all as specified. |
| 95 | S&F stainless steel handles of 100 mm size for kitchen cabinet shutter complete all as specified. |
| 96 | S&F 75mm Hasp and staple, aluminium anodised, wire type, stove enamelled black, including bolt to hinge plate and fixed with screws |
| 97 | S&F in repair alumnium curtain rod (Dropery rod) plastic coated 20 mm dia including end Knobs fancy type nickle polished golden or silve colour as per sample.complete all as specified as directed. |
| 98 | S&F in repairs fancy type brackets for fixing of 20mm dia dropery rod complete all as specified and directed. |
| 99 | S&F in repairs Cloth rod with caps and brackets 15 mm dia complete all as specified and directed. |
| 100 | Dismantling wrought iron or mild steel work of any description not otherwise provided forwindows grill etc. |
| 101 | S&F framed work such as grills, gratings etc, with ends of bars shouldered and / or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusteres, walk ways, railings, frame work of water tanks and similar work complete all as specified and directed. |
| 102 | S&F 2nd class hardwood small fittings such as brackets of any type of door and window stopper including all necessary articlesn exc 200 cu. cm each each all specified. |
| 103 | M&L preparation of new wooden surface any description not otherwise described and exc 10cm width or girth applying two coats of synthetic enamel paint over a coat of pink primer. |
| 104 | M/L preparing new steel surfaces of any description over 10cm width or girth and applying two coat of synthetic enamel paint over a coat off red oxide primer complete all as directed |
| 105 | S&F 75 mm size butt hinges medium weight cold rolled milled steel all as specified. |
| 106 | S&F 100mm size butt hinges medium weight cold rolled milled steel all as specified. |
| 107 | S&F 200mm long aluminium anodised barrel tower bolt of extruded section conplete. |
| 108 | Ditto, but 150mm long . |
| 109 | S&F 300 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed. |
| 110 | M&L for 150 mm size Aluminium handle cast type anodiesd complete all as specified as directed. |
| 111 | M&L Providing and injecting chemical emulsion for Post ConstructionalAntitermite Treatment along external wall where the apron is not ovidedusing chemical emulsion at the rate of 7.5 litres per sq.m of the vertical surface of the sub-structure to a depth of 300 mm including excavating channel along the wall and rodding etc. complete. |
| 112 | M&L Providing ATT and injecting chemical emulsion for Post Constructional Antitermite Treatment Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron |
| 113 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. |
| 114 | Material and labour for point wiring of one light/ fan/bell point controlled by one switch with two single core 1.5 sqmm cable (nominal area) stranded copper conductor, PVC insulated unsheathed cable, 1100 V grade in and including concealed PVC conduit of size not less than 20mm dia with modular metal flush box, 1.6 mm thick of suitable size and modular white cover plate with frame of suitable module and wiring to be terminated in pressed steel sunken boxes including all accessories and using single core 1.5 Sqmm (nominal area) stranded copper conductor, PVC insulated unsheathed cable as in earth wire (green colour) connected to common earth dolly complete all as specified and directed. |
| 115 | Ditto as above but for One 3 pin switch socket outlet point 5 Amps on independent board. |
| 116 | Ditto as above but for One 3 pin switch socket outlet point 5 Amps on same board with other switch. |
| 117 | Ditto as above but for One light point controlled by two Nos two way switch. |
| 118 | All as per item above here in before but with copper conductor cable for one 3 pin socket outlet, 15 amp independent, with cable 2.5 sqmm size. |
| 119 | M&L for Modular switch 1 way 6A, 1 module, flush button single pole, one way, complete as specified and directed by Engineer in charge. |
| 120 | M&L for Modular switch, 16 Amps, one module, one way complete all as specified and directed. |
| 121 | M&L for Modular socket outlet 2/3 pin combined 2 module, 6 Amps, 230 Volts AC circuit complete all as specified and directed by Engr-in-Charge. |
| 122 | M&L for Modular socket outlet 2 in 1, 6 pins 6A and 16A, combined 2 module, complete all as specified and directed by Engineer in charge. |
| 123 | M&L for Modular switch 2 way 6A, 1 module flush button single pole, one way, complete as specified and directed by Engineer in charge. |
| 124 | S & Fix ceiling rose surface backlite 65x50mm 3 terminals complete. |
| 125 | Supply and fixing lamp holder PVC body with back plate complete all as specified and directed. |
| 126 | S&F Modular Fan step regulator, 120W - 2 module complete all as specified and directed. |
| 127 | M&L for Modular bell push 5 Amps 230 V, AC circuit complete all as specified and directed. |
| 128 | M&L for call bell ding dong 230 V AC circuit complete all as specified and directed by Engr-in-Charge. |
| 129 | Supply and fixing 4 Module SP box including Modular socket outlet 16 Amps for AC, 240 Volts flush type white finish with MCB 16 Amps type 'C' flush mounted and LED indicator (RED) incl concealed point wiring on wall and surface wiring on ceiling/roof with necessary arrangements with 2.5 Sqmm single core 1100 Volts grade FRLS PVC insulated unsheathed multistranded copper conductor with and including PVC concealed conduit of medium grade with all fittings and Modular white cover plate with frame 4 module to accomodate all the accessories complete with internal connections, fixed with chromium plated screws and washers for switches and sockets, including 2.5 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor as earth continuity conductor connected to common earth dolly and including cutting chases in walls / floors for concealed conduit and making good disturbed surfaces by cement mortar (1:3) and to match with the existing surface/colour by using existing oil bound distemper/white wash complete all as specified and as directed. |
| 130 | Supply and fixing in repair LED lights fitting 1x 36W, 6500K, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. Make : Havells Cat No LHEXAPP7IN1W036 or equivalent in Bajaj/ Philips. |
| 131 | Supply and fixing in repair LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete. Make : Havells Cat No LHEXAZP7PN1W010 or equivalent in Bajaj/Philips |
| 132 | S&F in repair of rechargeable Emergency Inverter LED batten 20W, 3 feet delivering not less than 2000 lumens output, suitable for 230V ±10%, 50 Hz AC supply ,the fitting shall be equipped with inbuilt lithium-ion battery of minimum 2200 mAh capacity, capable of providing minimum 2 hours backup during power failure, with automatic changeover from mains to battery mode and vice versa. The system shall include protection against overcharging, deep discharge and short circuit complete all as specified and directed. |
| 133 | Supply and fixing in repair LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. |
| 134 | Supply and fixing in repair LED Lamp 12W, 220V, AC complete all as specified |
| 135 | Supply and fixing in replacement GI Pipe bend to shape 1.5 mtr (32/40mm dia as required at site) with two Nos clamps made out of 50x6mm flat and two Nos bolts with nuts duly grouted in wall or fixing on wall complete all as specified and directed. |
| 136 | Supply ,install, testing & commissioning in repair of indoor type, wall mounted (with anchor bolts & nuts) compartmentalized type Meter Cabinet for provision and fixing arrangements of 6 Nos. energy meters of overall dimension 1600mm (W) x 750mm (H) x 200mm (D) made out of 2.0 mm thick CRCA Sheet with front door having cut out duly covered with transparent polycarbonate / glass panel for viewing KWh meter / Timer and other door shall be opaque. All doors should have gasket and locking arrangement to meet ingress protection level IP-43. The cabinet shall be painted both internally and externally with powder coated paint (RAL 7032 : SIEMENS GREY) after necessary surface treatment. The cabinet shall be fabricated as per the drawing and comprising of following accessories :-a) Four pole MCB, 100 Amps with breaking capacity 16 KA having fixed thermal and fixed magnetic release and spreader link at both incoming and outgoing side.- 01 No.b) Copper Bus Bar of size 25mm x 3mm duly mounted on FRP insulators and necessary drilling for 1 incoming & minimum 6 outgoing connections and duly covered with heat shrinkable PVC sleeves of standard colour code - 4 Nos.c) MCB SPN 25 Amps, 10 KA - 6 Nos ( To be connected with 4 Nos Meters)d) MCB SP 06 Amps, 10 KA -2 No ( For common lighting & Bldg Security Lights)e) Analog time switch 16 Amp-01 Nof) LED indicating Lamps, 22mm with 3 Amps SP MCB-03 Nos.g) 3 Way Bakelite strip type cable connector 30 Amps rating - 06 Nosh) Dial type DIN rail mounting, Analog Time Switch 16 Amps / 230 Volts AC 50Hz, with battery back up, 24 Hrs programmable type with 1 NO & 1 NC output contact.- 01 No. (for security light).j) Internal wiring with 1100V grade FRLS PVC insulated multi flexible copper wire of sizes duly crimped with copper lugs of suitable size & type all as mentioned below :- i) MCCB to Bus Bar - 10.0 Sqmm copper ii) Bus Bar to Cable Connector via KWh meter and MCB - 6.0 Sqmm iii) Bus Bar to LED Lamp via MCB - 1.5 Sqmm |
| 137 | Supply and fixing in repair factory made epoxy powder coated distribution board SPN 12 ways double door with acrylic top cover (IP-43 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, strandard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts complete all as specified & directed. |
| 138 | Supply and fixing in repair MCB single pole 240 volt 'C' curve 10 KA 5 to 32 Amps capacity all as specified and directed. |
| 139 | Supply and fixing in repair MCB single pole & neutral 240 volt 'C' curve 10 KA 25 to 32 Amps complete all as specified and directed . |
| 140 | Taking down old and u/s sub main wiring of 2/3 runs of any sizes from any position including, making good disturbed surface of wall ceiling etc all as directed. |
| 141 | M&L for concealed sub main wiring using two single core PVC insulated, unseathed stranded copper conductor cable of size 4.0 Sqmm of voltage rarting upto and including 1100 volts drawn in and including PVC concealed conduit of dia not less than 25mm with all fittings and accessories, along with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 4.0 Sqmm (green colour) as earth continuity conductor all as specified and directed. (Note : Two runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit) |
| 142 | Supply and fix exhaust fan made of steel body complete with louvers shutters , 300 mm sweep, single phase, 230 Volts AC, ISI marked fixed properly at directed location with provisioning of suitable fixing/tightening arrangements and connecting/testing and including writing MES No complete all as specified and directed. |
| 143 | Supply and fix exhaust fan made of steel body complete with louvers shutters , 300 mm sweep, single phase, 230 Volts AC, ISI marked fixed properly at directed location with provisioning of suitable fixing/tightening arrangements and connecting/testing and including writing MES No including dismantling of old exhaust fan and depositing to MES AGE E/M store complete all as specified and directed. |
| 144 | Supply & Fixing ceiling fan 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush less direct current (BLDC) motor, class of insulation : B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service Value ( CMM/W) minimum 6.00, Air delivery minimum 210 CMM 350 RPM ( tolerance as per IS : 374 - 2019), THD less than 10 % ,electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise = 75 degree C (max), insulation resistance more than 2 mega ohm, suitable for 230 V , 50 Hz, single phase AC supply, earthing etc including necessary connection with ceiling rose with 3 core 1.0 Sqmm PVC insulated round flexible cable and writing MES No all including dismantling of ceiling fan and depositing to MES AGE E/M store complete all as specified and directed. |
| 145 | Supply and fix water heater storage vertical type, puff insulation type of 25 ltrs capactiy and 1500 watts, BEE Star rated-5, with glass line inner shell with Hot & Cold pipe, water connection pipe, electric connection and necessary fixing arrangement and including writing MES No including dismantling of water heater and depositing to MES AGE E/M store complete all as specified and directed. |
| 146 | Taking down ceiling fan by unscrewing nut , bolts, disconnection of electric cable from ceiling rose, ceiling cable end, removing blades , of any sweep and make and deposit to MES Store all as specified and directed. |
| 147 | M&L for replacing the conventional Ceiling fan rod with An anti-suicide fan rod of 260 mm and white in color with is a specially designed down rod used to hang a ceiling fan that incorporates a mechanism to prevent suicide by hanging.They typically work on Spring Mechanism having two parts, an upper and lower section, held together by a spring mechanism. Automatic Release, if a weight exceeding a certain threshold (typically around 20-25 kg) is applied to the fan (as would be the case in an attempt to hang), the rod's joint separates, and the spring expands. This expansion allows the fan and the applied load to descend safely, preventing the person from being fully suspended. The spring keeps the fan above the person's head, minimizing the risk of injury as they land on the ground. Benefits. The primary purpose is to deter and prevent suicide attempts by hanging from ceiling fans. They are designed to be safe for normal use, only activating when an abnormal load is applied, relatively easy installation and compatibility with most ceiling fan models including clamps and necessary related items all as per site requirement specified and directed by Engg-in-charge. with replacement of multistranded copper conductor cable of size 23/ 0.193 from ceiling rose to fan terminal including making necessary electric connections & testing complete all as specified & directed. Make- Gold life or equivalent as approved by GE.(Note: This is only designed for to prevent suicide by hanging, safe for normal use, not for risk of injury.)NOTE : (i) Quoted rate is deemed to be inclusive of Anti-Suicide Fan rod and rubber reel & testing of serviceable rubber reel complete all as specified & as directed to the entire satisfaction of the Engr-In-Charge. |
| 148 | Taking down existing Single phase UNSV energy meter of any type and make from existing position without disturbing other connection and deposit the same to AGE E/M store yard after noting down the reading from meter all as specified and directed. |
| 149 | Fixing only and connecting electric meters above 25 amps complete all as specified and directed. |
| 150 | M&L earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick, burried directly in to ground ( earth pit) not less than 2.25 metres deep below GL with top edge of earth plate ot less athn 1.50 m below ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, connected to GI lead wire of 4 mm dia.(7.50 m Long) by means of nuts, bolts and washers, checknuts of GI and protected by the GI pipe light grade 15 mm nominal bore(7.5 m long) for earth lead wire and watering pipe light grade of 20 mm nominal bore, 0.63 mm thick G I sheet funnel , wiremesh, earthing test point etc complete including necessary earth work and excavation in any type of soil , PCC 1:2:4 type B1 earth pit and Precast RCC cover 65 mm thick duly reinforced with 6 mm dia. MS round bars @ 100mm C/C both ways,with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SI Part I complete all as specified and directed and testing on completion. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |