| Sl. No. | Item Description |
| 1 | (a) Work Portion _ Civil |
| 2 | Excavation for roadway in earth, soil of all sorts, sand, gravel or soft murum including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50m. and spreading for embankment or stacking as directed. |
| 3 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material with all lifts and leads beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means |
| 4 | Excavation for foundation in earth, soils of all types, sand,gravel and soft murum, including removing the excavated material with all lifts and leads beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5m to 3.0m) By Mechanical Means |
| 5 | Excavation for foundation in Hard murum including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5 to 3.0m.) By Mechanical Means |
| 6 | Filling in plinth and floors with approved excavated material in 15cm. to 20cm. Layers including watering and compacting etc. complete. |
| 7 | Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete. |
| 8 | Transportation of cutting including all lifts and leads, laying in layers of 20cm to 30cm. breaking clods, dressing to the required lines, curves, grades and section, watering and compacting to not less than 97% of standard Proctor density for a lead of over 50m. to 300m. inclusive from the site of excavation to the site of deposition as directed. |
| 9 | Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper. |
| 10 | Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) treatment by treating the backfill in immediate contact with foundation at the rate of 5 litres of emulsion concentrate of 1.0 percent of clorophyrifos per One Square Metre of vertical surface area covering 10 years guarantee on bond paper. |
| 11 | Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent of clorophyrifos per One Square Metre of surface area covering ten years guarantee on bond paper. |
| 12 | Providing preconstructional antitermite treatment as per I.S. 6313 (Part-I) to the soil along the external face of building by punching holes of 1.2 of 1.5 C.M. diametre about 30 -60 cm deep at 15 cm c/c as close to the wall as possible and to inject 0.5 percent of aldrin or clorophyrifos at the rate of 7.5 litres per hole and sealing the same with proper filling and covering 10 years guarantee on bond paper. |
| 13 | Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete. |
| 14 | Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 15 | Providing and laying Cast in situ/Ready Mix cement concrete M-15 of trap/ granite/quartzite/gneiss metal for coping to plinth or parapet, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) With fine aggregate (Crushed sand VSI Grade) |
| 16 | Ground Floor |
| 17 | Fifth Floor |
| 18 | Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite/quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. columns as per detailed designs and drawing or as directed including Steel centering formwork, cover blocks laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 19 | Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite/quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork,cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 20 | Ground Floor |
| 21 | First Floor |
| 22 | Second Floor |
| 23 | Third Floor |
| 24 | Fourth Floor |
| 25 | Fifth Floor |
| 26 | Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite/quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 27 | Ground Floor |
| 28 | First Floor |
| 29 | Second Floor |
| 30 | Third Floor |
| 31 | Fourth Floor |
| 32 | Fifth Floor |
| 33 | Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 34 | Ground Floor |
| 35 | First Floor |
| 36 | Second Floor |
| 37 | Third Floor |
| 38 | Fourth Floor |
| 39 | Fifth Floor |
| 40 | Providing and laying Cast in situ/Ready Mixcement concrete M-30 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 41 | Ground Floor |
| 42 | First Floor |
| 43 | Second Floor |
| 44 | Third Floor |
| 45 | Fourth Floor |
| 46 | Fifth Floor |
| 47 | Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite / quartzite / gneiss metal for R.C.C. canopy as per detailed designs and drawings including steel centering, formwork, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing etc. complete (excluding reinforcement). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 48 | First Floor |
| 49 | Providing and laying Cast in situ/Ready Mix cement concrete in M-30 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 50 | Ground Floor |
| 51 | First Floor |
| 52 | Second Floor |
| 53 | Third Floor |
| 54 | Fourth Floor |
| 55 | Fifth Floor |
| 56 | Providing and laying Cast in situ/Ready Mix cement concrete in M-30 of trap / quartzite/granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 57 | Ground Floor |
| 58 | First Floor |
| 59 | Second Floor |
| 60 | Third Floor |
| 61 | Fourth Floor |
| 62 | Fifth Floor |
| 63 | Providing and laying Cast in situ/Ready Mix cement concrete in M-30 of trap / granite/gneiss / quartzite metal for R.C.C. fins of required thickness in position as shown on the drawings or as directed by Engineer-in-charge including steel centering, plywood / steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement, including cover block) Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 64 | Ground Floor |
| 65 | First Floor |
| 66 | Second Floor |
| 67 | Third Floor |
| 68 | Fourth Floor |
| 69 | Fifth Floor |
| 70 | Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. |
| 71 | Ground Floor |
| 72 | First Floor |
| 73 | Second Floor |
| 74 | Third Floor |
| 75 | Fourth Floor |
| 76 | Fifth Floor |
| 77 | Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete. |
| 78 | Ground Floor |
| 79 | Fifth Floor |
| 80 | Providing structural steel work in trusses, other similar trussed purlins and members with all bracing, gusset plates etc. as per detailed designs and drawings or as directed including cutting, fabricating, hoisting, erecting fixing in position, Making riveted/ bolted/ welded connection and one coat of anticorrosive paint and over it 2 coats of oil painting approved quality and shade etc. complete. |
| 81 | Fifth Floor |
| 82 | Providing fly ash brick masonry with conventional / I.S. type fly ash bricks in C.M. 1:6 in foundation and plinth including bailing out water manually striking joints, racking out joints watering and scaffolding etc. complete. |
| 83 | Providing Autoclaved Aerated Concrete Block masonary of conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in superstructure including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972) |
| 84 | Ground Floor |
| 85 | First Floor |
| 86 | Second Floor |
| 87 | Third Floor |
| 88 | Fourth Floor |
| 89 | Fifth Floor |
| 90 | Providing Autoclaved Aerated Concrete Block masonary of conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in Half brick thick wall including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972) |
| 91 | Ground Floor |
| 92 | First Floor |
| 93 | Second Floor |
| 94 | Third Floor |
| 95 | Fourth Floor |
| 96 | Fifth Floor |
| 97 | Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete |
| 98 | Ground Floor |
| 99 | First Floor |
| 100 | Second Floor |
| 101 | Third Floor |
| 102 | Fourth Floor |
| 103 | Fifth Floor |
| 104 | Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1Kilogramper bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete. |
| 105 | Ground Floor |
| 106 | First Floor |
| 107 | Fifth Floor |
| 108 | Providing water proof bedding for flooring of Bath and WC 25 mm thick in C.M. 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete. |
| 109 | First Floor |
| 110 | Second Floor |
| 111 | Third Floor |
| 112 | Fourth Floor |
| 113 | Fifth Floor |
| 114 | Providing and applying two coats of High Albedo paint having minimum Solar Reflective Index (SRI) 108 (with solar reflectance & thermal emittance tested as per ASTM) C 1549 and ASTM C 1371 respectively, VOC less than 10 cc/gm. The coating thickness and the methodology of application shall strctly as per manufacturer's specifitions and as approved by engineer in charge. Surface preparation includes cleaning with metal wire brush to remove all dust, fungus etc, washing with water all complete.The contractor shall give guarantee for the performance of SRI and also the durabitity of coating, all complete as per direction of Engineer - in- incharge. |
| 115 | Ground Floor |
| 116 | First Floor |
| 117 | Fifth Floor |
| 118 | Providing and fixing 20 to 25 mm thick rough shahabad box type waterproofing for basement or underground floor on a base of Cement concrete 1:3:6, including sub base of 2.50 centimeter thick Cement mortar 1:3 with conceal, secrete (RMW), Algae proof or other alike waterproofing liquids, raking of joints upto 35 mm depth, filling the joints with 6 mm size crushed metal, hand grouting with cement slurry, curing and cleaning, with 7 years guarantee on court fee stamp of Rs. 100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete ) |
| 119 | Providing and fixing 20 to 25 mm thick rough shahabad box type waterproofing treatment to vertical outside faces of Reinforced Cement concrete walls of basement or underground floor including filling the gap of 25 mm between rough shahabad and R.C.C. walls with cement grout mixed with water proofing liquid Algae proof or other alike with one tile lift method, brushing the joints horizontally with cement slurry mixed with water proofing liquid for width 30 to 35 mm and sloping coping over topmost tile with cement mortar 1:3, butting the bottom most with Cement concrete 1:2:4 mixed with water proofing liquid, curing, with 7 years guarantee on court fee stamp of Rs.100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete) |
| 120 | Providing internal cement plaster 12mm thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. |
| 121 | Ground Floor |
| 122 | First Floor |
| 123 | Second Floor |
| 124 | Third Floor |
| 125 | Fourth Floor |
| 126 | Fifth Floor |
| 127 | Providing internal cement plaster 20mm thick in Single coats in cement mortar 1:5 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete |
| 128 | Ground Floor |
| 129 | First Floor |
| 130 | Second Floor |
| 131 | Third Floor |
| 132 | Fourth Floor |
| 133 | Fifth Floor |
| 134 | Providing and applying plaster with plaster of paris in 6mm thickness to previously plaster surface in all position including preparing the surface scaffolding etc. complete. |
| 135 | Ground Floor |
| 136 | First Floor |
| 137 | Second Floor |
| 138 | Third Floor |
| 139 | Fourth Floor |
| 140 | Fifth Floor |
| 141 | Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. |
| 142 | Ground Floor |
| 143 | First Floor |
| 144 | Second Floor |
| 145 | Third Floor |
| 146 | Fourth Floor |
| 147 | Fifth Floor |
| 148 | Providing and applying Texture plaster with finishing with texture material of approved make in 3 to 4 millimeter thickness on previously plastered surface, including Plaster Groove 6mm thickness or Tape Grooves 35 to 45 mm thickness or as required, in all position including preparing the surface, scaffolding etc. complete. |
| 149 | Ground Floor |
| 150 | First Floor |
| 151 | Second Floor |
| 152 | Third Floor |
| 153 | Fourth Floor |
| 154 | Fifth Floor |
| 155 | Providing fine cement finish 1.5 mm thick over green plaster surface including scaffolding curing etc. complete. |
| 156 | Providing patti/ band 75mm wide on plastered surface 12 mm to 15 mm thick in C.M. 1:3 line and level including neat finishing scaffolding curing etc. complete. |
| 157 | Ground Floor |
| 158 | First Floor |
| 159 | Second Floor |
| 160 | Third Floor |
| 161 | Fourth Floor |
| 162 | Fifth Floor |
| 163 | Providing patti/ band 100mm wide on plastered surface 12 mm to 15 mm thick in C.M. 1:3 line and level including neat finishing scaffolding curing etc. complete. |
| 164 | Ground Floor |
| 165 | First Floor |
| 166 | Second Floor |
| 167 | Third Floor |
| 168 | Fourth Floor |
| 169 | Fifth Floor |
| 170 | Providing patti/ band 150mm wide on plastered surface 12 mm to 15 mm thick in C.M. 1:3 line and level including neat finishing scaffolding curing etc. complete. |
| 171 | Ground Floor |
| 172 | First Floor |
| 173 | Second Floor |
| 174 | Third Floor |
| 175 | Fourth Floor |
| 176 | Fifth Floor |
| 177 | Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc.complete. |
| 178 | Ground Floor |
| 179 | First Floor |
| 180 | Second Floor |
| 181 | Third Floor |
| 182 | Fourth Floor |
| 183 | Fifth Floor |
| 184 | Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete. |
| 185 | Ground Floor |
| 186 | First Floor |
| 187 | Second Floor |
| 188 | Third Floor |
| 189 | Fourth Floor |
| 190 | Fifth Floor |
| 191 | Providing and fixing false ceiling with eco-friendly light-weight calcium silicate tiles of spintone surface texture aerolite make or equivalent of size 595mm x 595mm having 15mm thick densified micro look edge and 100% humidity resistance incombustible as per BS 46part IV and thermal conductivity 0.043 w/m 0 KC and NRC 0.50 placed in true horizontal level suspended grid of size 600x600mm made from hot dipped G.I. steel sections ion silhouette profile, rotary stitched double webbed white with 6mm reveal profile (white/black), wherein, main T runner of size 42mmx14mm between main tee 600mm center-tocenter and secondary cross T of size 33x14x0.43mm thick of length 600mm long spaced inter-locked at middle of the first crossed T in each panel to form grid of 1200mmx600mm resting on periphery wall Profile wall section 19mm (7+7) x 19mmx0.40thicknesses and laying false ceiling for services like diffusers grills including cutting, making opening for light fittings, fixtures, , smoke detectors etc., wherever required. Main T runners suspended from ceiling with using G.I. soffit cleats of size 25x35x1.6 mm of required length fixed to the ceiling with 6mm dia and 50mm long dash fastener, 4mm dia G.I. adjustable rods with powder- coated/good quality G.I. level adjustment clips of 35x35x0.8mm spaced @1200, center-to- center along main T all complete at all heights as per the specifications, drawings and as per |
| 192 | Ground Floor |
| 193 | First Floor |
| 194 | Second Floor |
| 195 | Third Floor |
| 196 | Fourth Floor |
| 197 | Fifth Floor |
| 198 | Providing groove to required size at specified location as directed by Engineer, at junction of brick masonry wall and R.C.C beams or Column, at junction of composite masonry, including scaffolding, finishing, curing etc. complete. |
| 199 | Ground Floor |
| 200 | First Floor |
| 201 | Second Floor |
| 202 | Third Floor |
| 203 | Fourth Floor |
| 204 | Fifth Floor |
| 205 | Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete. |
| 206 | Ground Floor |
| 207 | First Floor |
| 208 | Second Floor |
| 209 | Third Floor |
| 210 | Fourth Floor |
| 211 | Fifth Floor |
| 212 | Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete |
| 213 | Ground Floor |
| 214 | First Floor |
| 215 | Second Floor |
| 216 | Third Floor |
| 217 | Fourth Floor |
| 218 | Fifth Floor |
| 219 | Providing and fixing heavy duty inter locking concrete Coloured paving blocks of 60 mm thickness of having a strength of 300 Kilogram/Sq.cm. of approved quality and shape on a bed of crushed sand of 25 to 30 mm thick including skirting joints and cleaning etc. complete |
| 220 | Providing and laying ceramic tiles having size 30 cm. x 60 cm. confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. |
| 221 | Ground Floor |
| 222 | First Floor |
| 223 | Second Floor |
| 224 | Third Floor |
| 225 | Fourth Floor |
| 226 | Fifth Floor |
| 227 | Providing and laying Antiskid Ceramic tiles of approved quality of size 30 cm x 30 cm and confirming to IS 15622-2006 (Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete. |
| 228 | Ground Floor |
| 229 | First Floor |
| 230 | Second Floor |
| 231 | Third Floor |
| 232 | Fourth Floor |
| 233 | Fifth Floor |
| 234 | Providing and laying machine cut machine Polished Kota stone flooring 25mm to 30mm thick and required width in plain/ diamond pattern on bed of 1:6 C. M. including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc.complete. |
| 235 | Ground Floor |
| 236 | First Floor |
| 237 | Second Floor |
| 238 | Third Floor |
| 239 | Fourth Floor |
| 240 | Fifth Floor |
| 241 | Providing Mirror polishing to Kota Stone including using all necessary stones and equipments cleaning, washing etc. complete. For Flooring |
| 242 | Ground Floor |
| 243 | First Floor |
| 244 | Second Floor |
| 245 | Third Floor |
| 246 | Fourth Floor |
| 247 | Fifth Floor |
| 248 | Providing and laying in position flooring of telephone black granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete. |
| 249 | Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete. |
| 250 | Ground Floor |
| 251 | First Floor |
| 252 | Second Floor |
| 253 | Third Floor |
| 254 | Fourth Floor |
| 255 | Fifth Floor |
| 256 | Providing and laying telephone black granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etc. complete. |
| 257 | Ground Floor |
| 258 | First Floor |
| 259 | Second Floor |
| 260 | Third Floor |
| 261 | Fourth Floor |
| 262 | Fifth Floor |
| 263 | Providing and laying chequered tiles of approved quality of size 30 cm x 30 cm, confirming to corresponding I.S. for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete. |
| 264 | Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 mm x 450 mm size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 mm thick supports with kadappah top 35 to 40 mm thick and polished granite 16 to 20 mm top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 cm height and top granite of 75 x 40 cm including cutting, opening for sink of required size in kadappah as well as granite etc. complete. (Platform top size 5.00 m x 0.60 m and height is 0.75 m) |
| 265 | Ground Floor |
| 266 | First Floor |
| 267 | Second Floor |
| 268 | Third Floor |
| 269 | Fourth Floor |
| 270 | Fifth Floor |
| 271 | Kitchen Trolley Providing and Fixing stainless steel kitchen trolley of overall 26 \\" height and 22\\" depth,supported on aluminium pipes ,trolley basket made out of 5 mm stainless steel rod fitted on telescopic channel of size 1.5 \\" x 20 \\" x 22 \\" on both sides of trolley of 12 \\" or above size, panel having 40Kilogramload bearing capacity of trolley made out of 20 mm PUC coated plywood and colour combination as directed by E-I-C.Inner side of panel covered by white mica ,100 mm s.s. decorative handle.(The width and height of individual compartments shall be kept as directed by Engineer-in-charge) |
| 272 | Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete. |
| 273 | Ground Floor |
| 274 | First Floor |
| 275 | Second Floor |
| 276 | Third Floor |
| 277 | Fourth Floor |
| 278 | Fifth Floor |
| 279 | Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces. (excluding the primer coat.) etc. complete. |
| 280 | Ground Floor |
| 281 | First Floor |
| 282 | Second Floor |
| 283 | Third Floor |
| 284 | Fourth Floor |
| 285 | Fifth Floor |
| 286 | Providing and applying 2 coats of 100% Pure acrylic low VOC and APEO & HCHO free water based paint of approved colour that belongs to class 1 flame spread resistance of approved make Paint should provide durable and long lasting silk finish with a high crack tolerance of upto 1mm. Paint should have an oustanding washability with high resistance to wide range of bacteria and fungus. Paint has to be applied on smooth and uniform surface prepared by an acrylic copolymer low VOC & Odour putty. This surface should be primed with water based low VOC Primer. The work activity should cover all aspects of applying paints from surface preparation as directed by Engineer in charge. |
| 287 | Ground Floor |
| 288 | First Floor |
| 289 | Second Floor |
| 290 | Third Floor |
| 291 | Fourth Floor |
| 292 | Fifth Floor |
| 293 | Providing and applying 2 Coats of 100% Pure acrylic water based paint with special heat reflectance property to withstand the harsh climate for period of atleast 10 years of approved make. Paint system should provide durable and long lasting finish with DFT of min 90 microns and should protect against concrete carbonation with R value of minimum 600 and equivalent concrete layer thickness value of min 150 cm. Paint should have breathability property and should be able to cover hairline cracks in the surface upto 0.5mm The paint has to be applied on a coat of high quality acrylic copolymer based alkali resistant primer with excellent penetrating properties including cleaning, with all leads and lifts at all levels etc complete, as directed by Engineer in charge. |
| 294 | Ground Floor |
| 295 | First Floor |
| 296 | Second Floor |
| 297 | Third Floor |
| 298 | Fourth Floor |
| 299 | Fifth Floor |
| 300 | Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete |
| 301 | Ground Floor |
| 302 | First Floor |
| 303 | Second Floor |
| 304 | Third Floor |
| 305 | Fourth Floor |
| 306 | Fifth Floor |
| 307 | Providing and fixing Country cut teak wood double or single leaf panelled shutters, 35 mm thick style top and freze rail 95 x 35 thick with lock and bottam rail 195 x 25 mm thick and panels without ventilator as per detailed drawing excluding the door frame, stainless steel fixtures and fastening and finishing the wood work with oil painting 3 coats complete |
| 308 | Ground Floor |
| 309 | First Floor |
| 310 | Second Floor |
| 311 | Third Floor |
| 312 | Fourth Floor |
| 313 | Fifth Floor |
| 314 | Providing and fixing 34 mm thick moulded door shutter consisting of solid core single leaf flush door of 30 mm thickness lipped with 15 mm ( 5mm x 3) thick x 30 mm width on one style and top rail and 10 mm (5mm x 2) thick x 30 mm width on other style and bottom rails. The inner panels laminated with 2 mm thick termite proof, water proof and fire resistant moulded PVC sheet with 2,4,6 design in different plain and /or prelim colours on one side after routing the moulded design on flush doors and 2 mm plain and /or pre lam PVC on other side using rubber adhesive on flush door and solvent cement adhesive on the PVC lipping etc. as per direction of Engineer in charge and manufacturers specification and drawing etc. complete. |
| 315 | Ground Floor |
| 316 | First Floor |
| 317 | Second Floor |
| 318 | Third Floor |
| 319 | Fourth Floor |
| 320 | Fifth Floor |
| 321 | Providing & Fixing in position Acoustical Doors along with 150 x 150 mm teak wood frame, doors made from 50mm Teak wood frame 600 x600 c to c filled with 1000 Gsm synthetic wool 50mm thick and 3mm Tecsound from both sides, 12mm waterproof ply & veneer from both sides , including 150mm heavy duty SS hinges (Geze / Dorma or eq.) 4 no each leaf, with Door-closer (Dorma / Geze or eq.) including cost of required Cut- Outs, decorative mouldings / finishing-items / melamine polish & Scaffolding as per Architectural & Acoustical Design & Instructions & Complete in all aspects .including all materials labour,finishing etc complete |
| 322 | Ground Floor |
| 323 | Second Floor |
| 324 | Fourth Floor |
| 325 | Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 mm x 1.22 mm box type, 5 mm thick sheet glass louvers, of approved quality etc. complete. |
| 326 | Ground Floor |
| 327 | First Floor |
| 328 | Second Floor |
| 329 | Third Floor |
| 330 | Fourth Floor |
| 331 | Fifth Floor |
| 332 | Providing and Fixing 30 MM thick BOTH SIDE PRELAMINATED SOLID PANEL PVC DOOR SHUTTER consisting of frame made out of M.S tubes of 19 guage thickness and, size 19 x 19 mm for styles and 15 x15 mm for the top and bottom rails, M.S frame shall have a coat of metel primer of approved make and manufacture. M.S frame shall be covered with heat mouled PVC 'C' channel made from 5 mm (+/0.25) thick prelaminated sheet of density 600 Kilogram/cbm ,of size 30mm thickness 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45? angle on either side forming stiles ? and 5 mm thick ,95 mm wide PVC sheet out of which 75 mm shall be falt and 20 mm shall be tapered in 45 on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be falt and 20 mm shall be tapered on both sides to form lock rail.Top,bottom and lock rail shall be provided either side of the panel. An additional 5 mm (+/0.25) thick PVC strip of 20 mm width is to be stuck on the bottom side of the ' c ' channel prelaminated paneling of 5 mm (+/0.25) thick PVC sheet to be fitted inside the M.S. frame welded/ sealed to the styles and rails with 5 mm (+/0.25) x 30 mm PVC sheet beading on either side and joined together with solvent cement adhesive etc ,10 mm thickness (5 mm (+/0.25) x 2 nos ) 20 mm wide cross PVC sheet as gap insert for the rail and bottom rail. Door to be fixed to frames with 3 nos M.S.powder coated but hinges of size 100 mm x 25MM x 2mm using 32 mm long steel screws drilled suitable to pass through both the walls of the M.S tube. Other hardwares |
| 333 | Ground Floor |
| 334 | First Floor |
| 335 | Second Floor |
| 336 | Third Floor |
| 337 | Fourth Floor |
| 338 | Fifth Floor |
| 339 | Providing and fixing in position. (as per I.S.1868 / 1982) Aluminium sliding window of two tracks with rectangular pipe having overall dimension ?63.50 x 38.10 x 1.02 mm at weight 0.547 Kilogram/One Running Metre. and window frame bottom track section 61.85 x 31.75 x 1.20 mm at weight 0.695 Kilogram/One Running Metre. Top and side track section 61.85 x 31.75 x 1.30 mm at weight 0.659 Kilogram/One Running Metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/One Running Metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/One Running Metre. And handle section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/One Running Metre. and top section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass with all required screws and nuts etc, complete. With powder coating without box |
| 340 | Ground Floor |
| 341 | First Floor |
| 342 | Second Floor |
| 343 | Third Floor |
| 344 | Fourth Floor |
| 345 | Fifth Floor |
| 346 | Providing and fixing in position (as per 1868 / 1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 Kilogram/One Running Metre. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 Kilogram/One Running Metre.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 Kilogram/Running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/One Running Metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/Running metre. and handle and top section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete. With powder coating without box |
| 347 | Ground Floor |
| 348 | First Floor |
| 349 | Second Floor |
| 350 | Third Floor |
| 351 | Fourth Floor |
| 352 | Fifth Floor |
| 353 | a) Supplying and fixing in position Aluminium four track sliding windows Powder Coated with outer frame made from section of over all size 122 mm x 45 mm, bottom section with drain section track weighing 1.83Kilogramper metre and top and side section of size 122x 31.75 mm weighing 1.15Kilogramper One Running Metre with shutter sections made of 18 mm x 40 mm size having average weight of 0.6Kilogramper One Running Metre (or as required size) with change in proportionate weight, with 6 mm float glass in three equal panels and alluminium coated stainless steel mosquito net in one (2/3 of opening) panel fixed with new neoprene gasket, shutters to be provided with nylon encased stainless steel rollers, necessary locks and handles complete. |
| 354 | Ground Floor |
| 355 | First Floor |
| 356 | Second Floor |
| 357 | Third Floor |
| 358 | Fourth Floor |
| 359 | Fifth Floor |
| 360 | Providing and fixing in position structural glazing faces of building made out of colour anodized aluminium frame curtain wall of 63 mm x 57 mm x 2.20 mm thick including toughened reflective glass 5 mm thick of 900x1200 mm size. The item shall include toughened coloured reflective glass 5 mm thick water proofing silicon sealant, G.E. winsil 10/20, G.E.ultra glaze including alumnium fixtures.S3 screws and nut bolts, scaffolding , m.s.angle cleats and frame work of 65 mm x 65 mm x 6 mm and scaffolding etc. complete. Minimum 20% area of structural glazing shall be openable for openable panels. aluminum hinges, wind stays and locking arrangements and aluminum angle or tee section of required size as directed by Engineer in Charge |
| 361 | Ground Floor |
| 362 | First Floor |
| 363 | Second Floor |
| 364 | Third Floor |
| 365 | Fourth Floor |
| 366 | Fifth Floor |
| 367 | Providing and fixing M40 grade thick vibrated pull cast or similar type concrete frame with chamfer conforming to I.S. 65241983 having 6 mm dia. bars 3 Nos. And stirrups @250 mm c/c and fixing in wall with 6 Nos of hold fast of 12 mm dia bars 500 mm long including primer and oil painting etc, complete) frame size 60 mm x 100 mm . |
| 368 | Terrace Floor |
| 369 | Providng and fixing in position anodised extruded aluminum partitions, partly glazed and partly laminated having frame made out of extruded tubular section of size 40 mm x 60 mm with 12 mm thick three layered flat pressed teak wood particle board bonded with BWP type exterior grade phenol formaldehyde synthetic resin conforming to IS 128231990, laminated on both sides,Novateakor equivalent and 5 mm thick selected quality plain/ float glass panels fixed with aluminum glass clips 12 mm x 12 mm and rubber cushioning beading to glass partitions as per approved drawing etc. compete |
| 370 | Ground Floor |
| 371 | First Floor |
| 372 | Second Floor |
| 373 | Third Floor |
| 374 | Fourth Floor |
| 375 | Fifth Floor |
| 376 | Providing and fixing in position, Single shuttered aluminium extruded powder coated openable door of overall size 0.90 m x 2.40 m with aluminium door frame of powder coated section 101.60 x 44.75mm , 3.18 mm thick and shutter comprising of powder coated section having bottom and lock rail of size 150 mm x 44.5 mm x 3.00 mm thick top rails 47.62 x 44.45 mm x 3.00 mm thick , vertical style 47.62 x 44.45 mm, 3.00 mm thick and for shutter plain glass panes 5 mm thick for top panels and 12mm thick both side laminated phenol bonded particle board panels for bottom panels etc. , I.S.I. mark , heavy duty, Hydraulic floor spring of 150Kilogramcapacity , having heavy duty concealed lock, necessary beading, glazing clips, PVC gaskets, 250mm length tower bolts, 150mm diam. pad handle, etc. as per detailed design and drawing or as directed by engineer in charge including all materials , labours, and equipment etc.Complete |
| 377 | Ground Floor |
| 378 | First Floor |
| 379 | Second Floor |
| 380 | Third Floor |
| 381 | Fourth Floor |
| 382 | Fifth Floor |
| 383 | Providing and fixing mild steel grill work for windows, ventilators, etc. 15 Kilogram/ One Square Metre as per drawing including fixtures necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting complete. |
| 384 | Ground Floor |
| 385 | First Floor |
| 386 | Second Floor |
| 387 | Third Floor |
| 388 | Fourth Floor |
| 389 | Fifth Floor |
| 390 | Providing and Fixing mat finish stainless steel (of 302 grade ) railing with top pipe of 50 mm dia. and vertical pipe of 38 mm dia at 0.60 m c/c or as required and horizontal pipes of 25 mm dia in three rows, all pipes of 2 mm thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 mm dia above newel post of 75 mm diameter etc. complete |
| 391 | Ground Floor |
| 392 | First Floor |
| 393 | Second Floor |
| 394 | Third Floor |
| 395 | Fourth Floor |
| 396 | Fifth Floor |
| 397 | Providing and fixing C.P. 2 Way BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge. |
| 398 | Ground Floor |
| 399 | First Floor |
| 400 | Second Floor |
| 401 | Third Floor |
| 402 | Fourth Floor |
| 403 | Fifth Floor |
| 404 | Providing and fixing 25mm diameter water meter with non-return valve including strainer, sockets/ union nut and including water meter box making locking arrangement and lock. [Without chamber]. |
| 405 | Providing and fixing 15 mm dia. screw down bib/ stop tap of brass including necessary socket union nut complete. |
| 406 | Ground Floor |
| 407 | First Floor |
| 408 | Second Floor |
| 409 | Third Floor |
| 410 | Fourth Floor |
| 411 | Fifth Floor |
| 412 | Providing and fixing 20 mm dia. screw down bib/ stop tap of brass including necessary socket union nut complete. |
| 413 | Ground Floor |
| 414 | First Floor |
| 415 | Second Floor |
| 416 | Third Floor |
| 417 | Fourth Floor |
| 418 | Fifth Floor |
| 419 | Providing and fixing screw down 15 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete |
| 420 | Ground Floor |
| 421 | First Floor |
| 422 | Second Floor |
| 423 | Third Floor |
| 424 | Fourth Floor |
| 425 | Fifth Floor |
| 426 | Providing and fixing push cock (Self closing tap) symet type of 15 mm dia. including necessary socket, testing etc. complete. |
| 427 | Ground Floor |
| 428 | First Floor |
| 429 | Second Floor |
| 430 | Third Floor |
| 431 | Fourth Floor |
| 432 | Fifth Floor |
| 433 | Providing and fixing White glazed with bottle trap earthenware Wash Hand Basin of 63x45 cm size including cold water piller taps, brackets, rubber plugs and brass chain, stop tap, chromium plate bottle trap and necessary pipe connections including UPAC waste pipe and trap upto the outside face of the wall, making good the damaged surface, testing etc. complete. |
| 434 | Ground Floor |
| 435 | First Floor |
| 436 | Second Floor |
| 437 | Third Floor |
| 438 | Fourth Floor |
| 439 | Fifth Floor |
| 440 | Providing and fixing Oval Type Under Counter Wash Hand Basin of 420 x 590 x 195mm size with pillar cock, C.P.Angular stop cock, long thread of approved make continental including SS bottle trap of necessary pipe connection up to the outside face of the wall, having Telephonic Black / Colour Granite of 180 mm thick fixed on Black Kadappa Framework, etc. Complete as directed by Engineer in charge. |
| 441 | Ground Floor |
| 442 | First Floor |
| 443 | Second Floor |
| 444 | Third Floor |
| 445 | Fourth Floor |
| 446 | Fifth Floor |
| 447 | Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap. |
| 448 | Ground Floor |
| 449 | First Floor |
| 450 | Second Floor |
| 451 | Third Floor |
| 452 | Fourth Floor |
| 453 | Fifth Floor |
| 454 | Providing and laying concrete pipes of I.S.NP. class of 150mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. |
| 455 | Providing and laying concrete pipes of I.S.NP. class of 300mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. |
| 456 | Providing , constructing and fixing 250 mm dia. Inspection chamber made up of UPVC material of thickness 3.5 mm and height of 259 mm with inlet and outlet of 110 mm dia. with 75 mm dia. U Trap, Ultra shaft pipe of Upvc material having height of 470 mm and fixing Ultra 250 mm dia. UPVC cover and frame in 150 mm thick in c.c.1:2:4, having crushed sand bed of 100 mm thick of size 550 mm dia. Including excavation and refilling the sides of chamber by crushed sand cushioning 150 mm thickness, connecting all required UPVC fittings with rubber lubricant etc. complete. |
| 457 | Providing , constructing and fixing 450 mm dia. Inspection chamber made up of Polypropylene / polyethylene material of thickness 3.5 mm and height of 388 mm with 160 or 200 mm main inlet (s) outlet and 110 and / or 160 mm branch inlets, with 450 mm dia. Ultra shaft pipe of HDPE material having height of 460 mm, having R.C.C. cover and frame fixing in 150 mm thick in c.c.1:2:4, having crushed sand bed of 150 mm thick of size 750 mm dia. Including excavation and refilling the sides of chamber by sand crushed cushioning 150 mm thickness, connecting all required UPVC fittings with rubber lubricant etc. complete. |
| 458 | Providing and fixing 450mm x 550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete. |
| 459 | Ground Floor |
| 460 | First Floor |
| 461 | Second Floor |
| 462 | Third Floor |
| 463 | Fourth Floor |
| 464 | Fifth Floor |
| 465 | Providing and fixing chromium plated towel rod 16 mm dia and 75 cm. in length including all accessories complete. |
| 466 | Ground Floor |
| 467 | First Floor |
| 468 | Second Floor |
| 469 | Third Floor |
| 470 | Fourth Floor |
| 471 | Fifth Floor |
| 472 | Providing and fixing stainless steel sink of size 600 x 510 x 200 mm incluidng coupling, outlet pipe, elbow and other necessary fitting, finishing etc. complete. |
| 473 | Providing and fixing C.P. sink cock with raised J\\" shaped swinging casted spout ofapproved make including necessary sockets/ union nut etc. complete.\\" |
| 474 | Providing and fixing C.P. Angular stop clock with wall flange of approved make continental including necessary sockets/union nut etc. complete. |
| 475 | Ground Floor |
| 476 | First Floor |
| 477 | Second Floor |
| 478 | Third Floor |
| 479 | Fourth Floor |
| 480 | Fifth Floor |
| 481 | Providing and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete. |
| 482 | Ground Floor |
| 483 | First Floor |
| 484 | Second Floor |
| 485 | Third Floor |
| 486 | Fourth Floor |
| 487 | Fifth Floor |
| 488 | Providing and fixing 40 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirements etc. complete. |
| 489 | Fifth Floor |
| 490 | Providing and fixing 15 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirement etc. complete. |
| 491 | Fifth Floor |
| 492 | Providing and fixing wall mixer with overhead shower,shower arm,hand shower with wall bracket having flow rate up to 12 liters/minutes of Jaquar/Cera/Hindware /Perryware or equivalent make including all necessary pipes,fittings etc.complete as directed by Engineer In Charge.( Make shall conform to manufacturer's Green product and shall got approved from the Engineer In Charge.) |
| 493 | Ground Floor |
| 494 | First Floor |
| 495 | Second Floor |
| 496 | Third Floor |
| 497 | Fourth Floor |
| 498 | Fifth Floor |
| 499 | Providing and fixing C.P. wall mixer with provision for overhead shower with 115mm long bend pipe and wall flange of approved make including necessary sockets/union nut etc. complete. |
| 500 | Ground Floor |
| 501 | First Floor |
| 502 | Second Floor |
| 503 | Third Floor |
| 504 | Fourth Floor |
| 505 | Fifth Floor |
| 506 | Providing and fixing Orissa Pan of size 580x445x260 mm with approved make flush valve including trap, C.I. soil and vent pipe upto outside face of wall including 100mm dia. C.I. plug, bend and necessary pipe connection, etc complete. As directed by Engineer in charge. |
| 507 | Ground Floor |
| 508 | First Floor |
| 509 | Second Floor |
| 510 | Third Floor |
| 511 | Fourth Floor |
| 512 | Fifth Floor |
| 513 | Providing and fixing white Opal series European type wall-hung, of size 400 mm x 370 mm x 575mm with approved make flush valve including soil pipe, vent pipe upto outside face of wall, 100mm dia C.I. plug bend inlet pipe all fittings, cutting & making good walls, floors etc as directed by Engineer in charge. |
| 514 | Ground Floor |
| 515 | First Floor |
| 516 | Second Floor |
| 517 | Third Floor |
| 518 | Fourth Floor |
| 519 | Fifth Floor |
| 520 | Providing and fixing white glazed earthenware lipped flat back/corner type Urinal with PVC 5 liters flushing cistern with fittings, inlet pipe with stop tap, brackets for fixing the cistern, 32 mm diameter P.V.C. flush pipe with fitting including lead soil pipe, lead trap and soil pipe connection up to the outside face of wall. |
| 521 | Ground Floor |
| 522 | First Floor |
| 523 | Second Floor |
| 524 | Third Floor |
| 525 | Fourth Floor |
| 526 | Fifth Floor |
| 527 | Grab bars-Providing SS grab bars set for accessible toilets comprising of 4 nos. Grab bars as specified below.(1 nos. wing grab bar + 1 nos. L shaped grab bar + 2 nos. straight grab bars = 1 typical set) 27a) Swing grab bar (1 NOS) Providing a S.S. 304 SWING HANDICAP GRAB BAR - 700 mm and of DIA: 32MM and thickness 1.5mm of the roved brand and make. 27b) L Shaped grab bar (1 NOS) Providing S.S. 304 L SHAPED DISABLED GRAB BAR of IZE-600MM (H) X 600MM (D) and 32MM DIA. and thickness mm of the approved brand and make. 27c) Straight grab bar (2 NOS) Providing S.STEEL 304 GRAB RAIL (600 MM),32MM DIA. and thickness 1.5mm of the approved brand and make. |
| 528 | Ground Floor |
| 529 | First Floor |
| 530 | Second Floor |
| 531 | Third Floor |
| 532 | Fourth Floor |
| 533 | Fifth Floor |
| 534 | Providing and fixing 75 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete |
| 535 | Ground Floor |
| 536 | First Floor |
| 537 | Second Floor |
| 538 | Third Floor |
| 539 | Fourth Floor |
| 540 | Fifth Floor |
| 541 | Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. |
| 542 | Ground Floor |
| 543 | First Floor |
| 544 | Second Floor |
| 545 | Third Floor |
| 546 | Fourth Floor |
| 547 | Fifth Floor |
| 548 | Providing , laying and fixing ,jointing Eco- drain 110 mm SN 8 Nu- Drain Upvc pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends, tees, coupler, etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated material etc. complete. |
| 549 | Providing , laying and fixing ,jointing Eco- drain 160 mm SN 4 Nu- Drain Upvc pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends, tees , coupler, etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated materialetc. complete. |
| 550 | Providing and fixing H.D.P container one piece moulded water tank made out of low density polythyler and built corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity above 1000 to 20,000 litres |
| 551 | Fifth Floor |
| 552 | Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 553 | Ground Floor |
| 554 | First Floor |
| 555 | Second Floor |
| 556 | Third Floor |
| 557 | Fourth Floor |
| 558 | Fifth Floor |
| 559 | Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 560 | Ground Floor |
| 561 | First Floor |
| 562 | Second Floor |
| 563 | Third Floor |
| 564 | Fourth Floor |
| 565 | Fifth Floor |
| 566 | Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 567 | Ground Floor |
| 568 | First Floor |
| 569 | Second Floor |
| 570 | Third Floor |
| 571 | Fourth Floor |
| 572 | Fifth Floor |
| 573 | Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 574 | Ground Floor |
| 575 | First Floor |
| 576 | Second Floor |
| 577 | Third Floor |
| 578 | Fourth Floor |
| 579 | Fifth Floor |
| 580 | Providing and fixing on walls /ceiling/ floor 40 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 581 | Ground Floor |
| 582 | First Floor |
| 583 | Second Floor |
| 584 | Third Floor |
| 585 | Fourth Floor |
| 586 | Fifth Floor |
| 587 | Providing and fixing on walls/ ceiling/ floor 50 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. |
| 588 | Ground Floor |
| 589 | First Floor |
| 590 | Second Floor |
| 591 | Third Floor |
| 592 | Fourth Floor |
| 593 | Fifth Floor |
| 594 | Providing and fixing 15 cm rigid PVC Nahani trap including PVC grating ,bend,connectingpiece of UPVC pipe up to the outside face of wall ,making the good damaged surface and testing etc. complete |
| 595 | Ground Floor |
| 596 | First Floor |
| 597 | Second Floor |
| 598 | Third Floor |
| 599 | Fourth Floor |
| 600 | Fifth Floor |
| 601 | Providing and fixing P.V.C. Rain water pipes of 160mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and One Number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. |
| 602 | Ground Floor |
| 603 | First Floor |
| 604 | Second Floor |
| 605 | Third Floor |
| 606 | Fourth Floor |
| 607 | Fifth Floor |
| 608 | Providing and laying in trenches 15 mm dai. CPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 609 | Providing and laying in trenches 20 mm dai. CPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 610 | Providing and laying in trenches 25 mm dai. CPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 611 | Providing and laying in trenches 32 mm dai. CPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 612 | Providing and laying in trenches 40mm dai. CPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 613 | Providing and laying in trenches 50mm dai. CPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 614 | Providing and fixing in position UPVC ultra violet stabilized 110 mm outer diameter cowl dome confirming to I.S.-4985 including making joints with solvent cement etc. complete |
| 615 | Fourth Floor |
| 616 | Fifth Floor |
| 617 | Providing and fixing Glass self 125 mm wide and 600 mm long with necessary chromium plated brackets providing T.W.gutties etc. complete |
| 618 | Ground Floor |
| 619 | First Floor |
| 620 | Second Floor |
| 621 | Third Floor |
| 622 | Fourth Floor |
| 623 | Fifth Floor |
| 624 | Providing and fixing 90 cm x 60 cm Granite plate engraving 10 cm. Height letter, figures including painting the lefters/figures with approved colour and shade complete |
| 625 | Providing and Fixing of Mineral Fibre Board Acoustical Suspended Ceiling System with ultima (Bevelled Tegular) Edge Tiles of size 15mm Exposed GRID. The tiles should have Humidity Resistance (RH) of 99%, NRC 0.7, Light Reflectance 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 20mm , suitable for Green Building application, with Recycled content of 32%. The tile shall be laid on precoated G.I.channel on XL2 Clip having a web height of 32 mm with 15 mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm and 600 mm Cross Tees with a web height of 32 mm and a load carrying capacity of 7.7 Kilograms/M2 and minimum pull out strength of 100 Kilograms.. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system. The Tile and Grid system used together should carry a 10 year warranty. products approved as per GRIHA and BS 476 etc. complete. |
| 626 | Ground Floor |
| 627 | Second Floor |
| 628 | Fourth Floor |
| 629 | ACOUSTICAL WALL PANELLING - FABRIC WRAPPED OF SIZE: 600X600/1200X25MM Providing and Fixing of Acoustical Wall Panel with square edges made of fibre glass substrate 25mm thick, wrapped on the front side with an acoustically transparent fabric as per the approved shade (Husk, Copper, Sangria, Sesame, Coffee, Charcoal, Titanium, Flame, Peanut and Shell). The panel shall be classified for Fire Class A, as per ASTM E- 84. The Acoustical Wall Panel shall be of sizes 600x600mm (Nominal) or 600x1200mm (Nominal) and shall achieve an NRC of 0.85 (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) with 50mm airgap as per ASTM C423 to be fixed to wall on a framework of wooden battens and using Wall panel Impalers (supplied by the manufacturer) or by using construction adhesives (as per the instructions laid down by the manufacturer). The fibre glass substrate shall have a recycle content of 85%. Installation:An appropriate vapour barrier (by others) shall be applied/installed on the vertical surface before the installation to properly seal against entry of any moisture. Vapour barrier (by others) shall be installed as per Manufacturer's recommendation. Install wooden batten grid (provided by others) of section 50x50mm or as approved by the Architect on the solid wall/partition to provide level and plumb surface. The Impalers shall be fixed to the battens using self-tapping screws, 3 nos. in case of 600x600mm and 4 nos. in case of 600x1200mm. Silica based construction adhesive (by others) to be dabbed on to the projecting elements (spikes) of the Impalers. Wall Panels shall be pierced through the spikes of the Impalers ensuring the line and level of the panels are maintained |
| 630 | Ground Floor |
| 631 | Second Floor |
| 632 | Fourth Floor |
| 633 | Providing and fixing colour coated Zincalume ( R ) AZ150 ( min 150 gms/sq.mt. total on each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min.550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% aluminium 43.4% zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyester paint coat ( with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950- 1050 mm effective cover width and nominal 25-30 mm deep ribs with subtle square fluting in the five pan at nominal 180-250 mm center- to-center. The end rib shall be designed for anti-capillary groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. complete. (weight of profile 4.52 Kilogram/ One Square Metre) |
| 634 | Ground Floor |
| 635 | Fifth Floor |
| 636 | Providing and fixing in position alluminium strips of size 50mm x 3mm for nosing the steps including fixing with screws and raval plugs, bending and cutting to the required shape and size, finishing with paint, necessary mortar bedding of 1:3 cement mortar to get exact line and level including watering and curing etc.complete |
| 637 | Ground Floor |
| 638 | First Floor |
| 639 | Second Floor |
| 640 | Third Floor |
| 641 | Fourth Floor |
| 642 | Fifth Floor |
| 643 | Providing and fixing lightening conductor system comprising of erecting Air- Termination consisting of tubular copper rod of 25mm dia. 1.2 mm thick with multiple points head 1.2 mt. long ( Heavy Duty) welded or clamped to G.I. pipe pole B grade 50 mm diaof requiired length with M.S. round bnase plate 25 Cm diam and 10mm thick at bottom embeded in cement concrete 1:3:6 dfoundation of size 45 cm diam x 45 cm Height and providing earthing with copper earth plate of size 60 x 60 x 0.3 cms with cadmium plated nut bolts to fix earthing strip burried in specially prepared earth pits 1.5 metre below ground level with 40Kilogramcharcoal and salt with altemate layers of charcoal and salt and G.I.pipe 40mm dia 2 meter length burried in earthe upto earthling plate remining portion above ground level for watering and refilling comcpete Note- Copper strip fropm lightening conductor is not considered in this item. |
| 644 | Supply, fixing and installation of 4mm thick Aluminium Composite Panel (ACP) of approved colour for external cladding in combination of solid and metallic colours, including all necessary Framework, support and complete weather sealing as per architectural drawing. The Aluminium Composite Panel (ACP) should be made out of thermoplastic core of low-density polyethylene LDPE (100% virgin mix), sandwiched between two aluminium sheets of ALLOY GRADE- 5000 series, each not less than 0.50 mm thick, total thickness of aluminium composite panels not to be less than 4 mm, the exposed surface thereof shall have Stove lacquered finishing coat not less than (26 + - 2) micron (containing minimum 70% kynar 500 based PVDF) of colour and shade as per architectural design. The inside surface (facing the building exterior surface)shall have polyster based powder coating not less than 25 Micron with protective peel-off foil on the exterior face (peel off film will in no case leave any adhesive mark over the composite panel surface after it is peeled off). The supporting framework shall be made out of 50 mm X25mm X 3mm thick Aluminium section to be spaced horizontally and vertically for fixing of panel of size 900 mm X 1200 mm and fixed to the building structure as per design through 50mm X50mm X5 mm MS angle clamps prefixed to masonry or slab, columns with Hilti make anchor fastener screws. The fixing of panel to be done with the help of VHB tapes and screws and all the sealing of joints to be done with weather sealent Silicon as directed by Engineer-in-charge. (Prior permission of S.E. is necessary before inclusion of this item in estimate) |
| 645 | First Floor |
| 646 | Providing soak pit of size 120cm x 120cm x 120cm including excavating and filling with brick-bats. |
| 647 | RWH - Shallow Percolation Pit providing, constructing 2.0m deep shallow depth percolation pit comprising of 1.0m dia pre-cast RCC rings, 300mm thick side filling around outside of RCC rings (annular space) with 40mm size boulders including filling of percolation pit up to 0.5m depth (from bottom up) with 25-75mm clean washed gravels followed by 0.5m depth of 10-25mm of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) media layer including covering with RCC slab, manhole frame & cover, PVC rungs etc. including arrangement for inlet & outlet pipe, excavation & backfilling as shown in the drawing. The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge |
| 648 | Providing and installing bio digester unit based on DRDO technology made of fibre reinforced plastic (FRP) having composition and following technical specifications and including necessary pipe and accessories up to 3 meter length, excluding the necessary excavation for installing the bio digester. Percentage of fibre glass (glass content in fibre glass should be minimum 30%): -33.33% Percentage of polyester resin: - 66.67% Water absorption (as per ASTM):-0.30% Flammability as per ASTM Tensile strength:-115 MPA Specific Gravity at 25 degree centigrade 1.45 Izod impact strength:-65KJ/M2 Heat defection/distort temperature:-65deg C Corrosion resistance (Non Corrosive) fitted with Inlet pipe size rigid PVC: -100mm Outlet pipe size rigid PVC:-80mm Gas outlet rigid PVC with Valve: 20mm Bacteria immobilization PVC mattes (on all partition) With DRDO TOT licensee and latest batch certificate(month & year of supply) and capacity as below c) Up to 25 user size (1.5mx1.0mx1.0m), Capacity of biodgester:-1500 liters, Area of top, bottom and side walls:- 8 sq.m, Area of partition walls: 2 sq.m, Total weight of frp: - 82.80 Kilogram, Bacteria inoculums quantity: - 600 liters, Minimum thickness of side walls / top and bottom: 5mm, One Number of inside partitions: - 3, Minimum thickness of partition wall: 3mm |
| 649 | Providing and installing bio digester unit based on DRDO technology made of fibre reinforced plastic (FRP) having composition and following technical specifications and including necessary pipe and accessories up to 3 meter length, excluding the necessary excavation for installing the bio digester. Percentage of fibre glass (glass content in fibre glass should be minimum 30%): -33.33% Percentage of polyester resin: - 66.67% Water absorption (as per ASTM):-0.30% Flammability as per ASTM Tensile strength:-115 MPA Specific Gravity at 25 degree centigrade 1.45 Izod impact strength:-65KJ/M2 Heat defection/distort temperature:-65deg C Corrosion resistance (Non Corrosive) fitted with Inlet pipe size rigid PVC: -100mm Outlet pipe size rigid PVC:-80mm Gas outlet rigid PVC with Valve: 20mm Bacteria immobilization PVC mattes (on all partition) With DRDO TOT licensee and latest batch certificate(month & year of supply) and capacity as below d) Up to 40 user size (2.0mx1.0mx1.0m), Capacity of biodgester:-2000 liters, Area of top, bottom and side walls: - 10 sq.m, Area of partition walls: 3 sq.m, Total weight of frp: - 106.20 Kilogram, Bacteria inoculums quantity: - 600 liters, Minimum thickness of side walls / top and bottom: 5mm, One Number of inside partitions: - 3, Minimum thickness of partition wall: 3mm |
| 650 | Providing and fixing board displaying information, such as 'Name of work, Tender cost, Name of Contractor, Work completion and liability period etc', having rectangular shape of 1.20m x 0.90m size made out 18 gauge (1.25mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border / messages / symbols etc. with approved colour shade paint complete, on M.S.angle of size 35 x 35 x 3 mm frame with properly cross braced M.S. angles of size 35mmx35mmx3mm duly painted including Two M.S. angle iron posts of size 65 mm x 65 mm x 6 mm, 3.65 m long painted with alternate black and white bands of 25 cm width including all fixtures etc.and fixing the boards in 1:4:8 concrete block of size 60 cm x 60 cm x 75 cm including, excavation, refilling, transportation, and labour etc complete. |
| 651 | Providing and laying Cast in situ/Ready Mixcement concrete M-35 of trap / granite /quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 652 | Ground Floor |
| 653 | First Floor |
| 654 | Second Floor |
| 655 | Third Floor |
| 656 | Fourth Floor |
| 657 | Fifth Floor |
| 658 | Providing and laying Cast in situ/Ready Mix cement concrete M-35 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 659 | Ground Floor |
| 660 | First Floor |
| 661 | Second Floor |
| 662 | Third Floor |
| 663 | Fourth Floor |
| 664 | Fifth Floor |
| 665 | Providing and fixing in position to the exact profile and prestressing the high tensile strands to specified ultimate strength, standard end anchorages, cable ducts, grouting ducts after prestressing and bearing plates with wedges as per detailed drawings including necessary plant and machinery for prestressing etc. complete. |
| 666 | Ground Floor |
| 667 | First Floor |
| 668 | Second Floor |
| 669 | Third Floor |
| 670 | Fourth Floor |
| 671 | Fifth Floor |
| 672 | Providing and laying machine cut machine polished machine cut Kota stone slabs 20 to 25 mm thick for treads and risers of steps and staircases, with rounded nosing for the treads on a bed of 1:4 cement mortar including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete. |
| 673 | Ground Floor |
| 674 | Fifth Floor |
| 675 | a) Supplying and fixing in position Aluminium four track sliding windows Colour anodized with outer frame made from section of over all size 122 mm x 45 mm, bottom section with drain section track weighing 1.83Kilogramper metre and top and side section of size 122x 31.75 mm weighing 1.15Kilogramper One Running Metre with shutter sections made of 18 mm x 40 mm size having average weight of 0.6Kilogramper One Running Metre (or as required size) with change in proportionate weight, with 6 mm float glass in three equal panels and alluminium coated stainless steel mosquito net in one (2/3 of opening) panel fixed with new neoprene gasket, shutters to be provided with nylon encased stainless steel rollers, necessary locks and handles complete. |
| 676 | Fifth Floor |
| 677 | Providing and fixing collapsible steel gate in one / two leaves with hot rolled vertical channels of 18 x 9 x 3 mm minimum size, crossings of M.S. flats of size 18 x 5 mm T or E section for runner of minimum 40 x 6 mm size for flange, M.S. flat for top runner of minimum size 40 x 12 mm with roller wheels confirming to grade F.G. 150 fitted with snap headed rivets of minimum size 6 mm max. spacing of vertical channels be 100 mm enclosed gate position and clear space of 150 mm between two sets of crossings with hold fasts, stoppers, spaces, handles, locking arrangement and one coat of red lead primer and oil painting etc. complete. (I.S. 105211983). |
| 678 | Fifth Floor |
| 679 | Providing and fixing White Glazed Earthenware Squatting plate (Ladies Urinal) with P.V.C. flushing cistern of 5 liters capacity with fitting, inlet pipes and stop tap, brackets for fixing the cistern, 32 mm dia. P.V.C flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap, soil pipe connectionup to the outside face of the wall |
| 680 | Ground Floor |
| 681 | First Floor |
| 682 | Second Floor |
| 683 | Third Floor |
| 684 | Fourth Floor |
| 685 | Fifth Floor |
| 686 | Providing and laying in situ /Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering formwork, laying/pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 687 | Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 688 | Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite/quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 689 | Providing fly ash brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete |
| 690 | Providing and fixing 50 mm. dia. medium class G.I.pipe gate with wicket gate of approved drawing with all fixtures and fittings in two leaves with strong hold fast embedded in c.c. block at top and bottom with locking arrangement including cutting, bending, making holes and with one coat of primer etc. complete. |
| 691 | Providing and erecting 1.5 metre high wire fencing with seven rows of barbed wire supported on M.S.Angles ( 50mm x 50mm x 6mm) at 2.5 Metres, Center to center including excavating pits for foundqtion, fixing post in cement cocnrete 1:4:8 of size 45 x 45 x 45 cm fastening the wire and painting the M.S.Angles with one coat of red lead primer and two coats of painting etc.complete. |
| 692 | Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader/ Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - I Material |
| 693 | Supplying hard murum/ kankar at the road site, including conveying and stacking complete. |
| 694 | Spreading hard murum/ soft murrum/ gravel or kankar for side width complete |
| 695 | Compacting the hard murum side widths including laying in layers on each side with vibratory roller including artificial watering etc. complete. |
| 696 | Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate ( natural sand/ VSI grade finely washed crushed sand) conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, , cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor /by suitable means as approved by Engineer-in- charge , compacting with vibratory roller, finishing, curing and including preparation of sub-grade surface if required etc. complete. with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. |
| 697 | Providing and casting in situ or precast tapering R.C.C. M-20 Mountable type Kerb with gutter ( as per IRC 86 1983) embedded 125mm below ground level over M-10 PCC finished neatly with C.M. 1:2, setting the same in C.M. 1:2, including the required excavation in any strata and removing the excavated stuff any where in city and redoing the surface as specified and directed by Engineering In-charge. Using Concrete Batching and Mixing Plant |
| 698 | Providing and laying in situ cement concrete M -30 with tremix treatment for 200 mm thickness for Concrete Road is including laying plastic sheet for 125 micron thickness with groove cutting of 4 mm wide and 20 mm deep with necessary refilling with polysuphide sealent (Pouring grade) confirming to BS : 5212 - 1989 into sawed groove widened at top for sealent reservoir of specified size and shape as per detailed drawing including fixing Polyethylene foam backer rod of required diameter ( excluding reinforcement) with coarsen and fine aggregate Using V.S.I.Quality Artifitial Sand etc. complete with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. |
| 699 | Providing and fixing in position TMT FE 500, tie bars precoated with anticorrosive epoxy paint of 12 mm dia. 70 cms.long and at 30.00 cm. C/C and wherever directed including handling, straightening wrapping with paper of approved quality for half length, necessary cutting, handling, straightening , supported by assembly of TMT FE 500, chairs with proper alignment etc. complete. |
| 700 | Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 cm to 20 cm thick including hand packing and compacting etc. complete. |
| 701 | Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 702 | Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 703 | Providing and laying Cast in situ/Ready Mixcement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 704 | Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting , curing , finishing and rougheningthem if special finish is to be provided and curing complete.(Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 705 | Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete. |
| 706 | Providing neeru finish to plastered surfaces in all positions including scaffolding and curing etc. complete. |
| 707 | Providing and laying vitrified matt fininsh tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete. |
| 708 | Providing and laying vitrified stone effect finish tiles having size 590 to 605 mm x 590 to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including required position laid on a bed of 1:4 cement mortarincluding neat cement float, filling joints, curign and cleaning etc. complete. |
| 709 | Providing and applying three coats of water proof cement paint of approved manufacture and of approved colour to new plastered surfaces including scaffolding if necessary, cleaning and preparing the surface, watering for two days etc. complete. |
| 710 | Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 mm with lock plate of 3.15 mm thickness reinforced with 35 x 35 x 5 mm angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth and thickness not less than 65 mm and 3.15 mm respectively with hold fast arrangements, M.S. Bracket plate 300 x 300 x 3.15 mm minimum size and shape with square bar, suspension shaft of minimum 32 mm diameter, hood cover of M.S. sheet not less than 0.9 mm thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc. complete. (I.S. 62481979) (With mechanical gear) |
| 711 | Borewell work (including transportation) : Drilling 200/215 mm dia. borewell in soil, soft murum, Hard Murum, and 150 mm dia. in Hard murum with all machinery, fule, labour etc. complete as directed by Engineer in charge |
| 712 | After completion of Drilling bore well, capacity test by flushing (Air lift method) is measured with 90 degree \\"V\\" notch etc. complete |
| 713 | PVC casing pipe : Providing and fixing 180 mm dia. PVC casing pipe (6 Kg/ Sq. cm.) (I.S. 4985-1988) with lowering, handling and grouting etc. complete as directed by Engineer in charge |
| 714 | Lowering and grouting of 180 mm diameter P.V.C. casing pipe (8 Kg/ Sq.cm) I.S. 4985/1988 etc. complete |
| 715 | PVC casing pipe Cap : Providing and fixing 180 mm dia. PVC casing pipe cap with handling and fixing etc. complete as directed by Engineer in charge |
| 716 | Providing and fixing heavy duty inter locking concrete Coloured paving blocks of 80 mm thickness of having a strength of 300 Kilogram/Sq.cm. of approved quality and shape on a bed of crushed sand of 25 to 30 mm thick including skirting joints and cleaning etc. complete |
| 717 | Providing and fixing green marble of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing / moulding the sharp edges wherever necessary, curing, etc. complete. |
| 718 | Providing and applying two coat of water based cement paint to un plastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence etc. complete. (applying 1 litre paint on 2 One Square Metret) |
| 719 | Providing and Fixing Rollar Blinds AMI Make or approved make & shade of 38mm round Aluminium channel with Blackout fabric & telting with chain (Ball) system with all necessary fixtures and fitting etc. complete. (Sample to be final by Engineer In-charge prior execution of work) |
| 720 | Ground Floor |
| 721 | First Floor |
| 722 | Second Floor |
| 723 | Third Floor |
| 724 | Fourth Floor |
| 725 | Fifth Floor |
| 726 | Low Height Openable Storage @ 900Lx450x750HT Providing and fixing Openable Steel Storage of 900 x 450 x 750Ht, with 2 adjustable shelves, Complete body & shutter made in 0.8 mm thick & Top in 2 mm thick CRCA, 2 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns. with 25 mm. thk additional Top on top of storage as as per drawing |
| 727 | Ground Floor |
| 728 | First Floor |
| 729 | Second Floor |
| 730 | Third Floor |
| 731 | Fourth Floor |
| 732 | Fifth Floor |
| 733 | Wardrobe with Mirror @ 900LX 600DX 1965H Providing and Fixing Wardrobe with Mirror of size 900LX 600DX 1965H The wardrobe side panels and doors are made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The shelves are made of 18mm thick Prelam Particle Board with decorative laminate on both sides. The top is made of 36mm prelam particle board with decorative laminate on both sides. (18mm Prelam Particle board and 18mm batons on all sides to achieve 36mm overall thickness). The exposed edges of the top are sealed with 2mm thick PVC edge Banding. The top most part of the wardrobe has an aluminum hanger rod of EBCO make. One drawer of size 400(W) x 150(H) x 450 (D) made of 18mm thick prelam Particle Board has been considered. The drawer will have a multipurpose lock of EBCO premium make. The wardrobe handles are Satin SS finish of 160mm pitch. The wardrobe has a multipurpose lock of EBCO make. All hinges considered are Hettich make. Necessary good quality hardwares have been considered as required. |
| 734 | Ground Floor |
| 735 | Third Floor |
| 736 | Fourth Floor |
| 737 | Fifth Floor |
| 738 | Tea Table 900mm X 750mm X 450mm for m.s. ante chamber Providing And Fixing Of Tea Table 900mm X 750mm X 450mm With 12mm Thick Colour Eitched Tempered Glass With Bevelled Drawing Made Out Of 18mm Thick Waterproofing Ply. The Outer Laces To Be Finished With High Quality 4 Mm Thik Veneer Or 1 Mm Thik Mica Etc. |
| 739 | First Floor |
| 740 | Second Floor |
| 741 | Third Floor |
| 742 | Fourth Floor |
| 743 | Fifth Floor |
| 744 | Providing & Arrangemnt of High Back, Synchronized Mechanism with Multiple Locking, Adjustable Armrest, Gaslift for Seat height adjustment, Standard 5-prong P/Nylon Base with Leatherite Upholstery |
| 745 | Ground Floor |
| 746 | First Floor |
| 747 | Second Floor |
| 748 | Third Floor |
| 749 | Fourth Floor |
| 750 | Fifth Floor |
| 751 | Providing & Arrangemnt of MId Back, Normal Syncro Mechanism , Fixed Armrest , Gaslift for Seat height adjustment, Standard 5-prong/Nylon Base with Leather Upholstery |
| 752 | Ground Floor |
| 753 | First Floor |
| 754 | Second Floor |
| 755 | Third Floor |
| 756 | Fourth Floor |
| 757 | Fifth Floor |
| 758 | Providing & Arrangemnt of Mid Back, ECO CTS Mechanism , Fixed Armrest , Gaslift for Seat height adjustment, Standard 5-prong P/Nylon Base with Fabric Upholstery |
| 759 | Ground Floor |
| 760 | First Floor |
| 761 | Second Floor |
| 762 | Third Floor |
| 763 | Fourth Floor |
| 764 | Fifth Floor |
| 765 | Public Seating Chair. - 3 Seater Providing and Fixing 3 seater Public seating chair made of complete metal with Legs in Crome finish and seates in silver powder coating finish. |
| 766 | Ground Floor |
| 767 | First Floor |
| 768 | Second Floor |
| 769 | Third Floor |
| 770 | Fourth Floor |
| 771 | Fifth Floor |
| 772 | Providing & fixing in position, heavy duty fully upholstered Auditorium chairs 520 mm c to c tip-up type. Height of back should be less than 1030 mm with plastic protective cover on back and bottom having teak wood handles. Back to back distance is 1000mm. The auditorium chairs should be of following specifications 1. Powder Coated Heavy duty MS Stand. 2. Individually moulded , ergonomically designed seat and back cushions. 3.Moulded Polyurethane Foam cushion. PU foam density 48 - 52 Kilograms/cu.mtr 4. Moulded Polyurethane Foam manufactured in certified ISO 9001 facility to ensure consistency in density for longevity .5.Upholstered in Foam laminated stretch sandwich Fabric for clean finish and soft comfortable feel as per the colour & pattern selected by the client. 6.Seat and Back should have moulded synthetic protective cover. 7. Wooden or PU armrest 65mm x 20mm - 330mm long . 8.Mounted using Anchor fasteners. |
| 773 | Ground Floor |
| 774 | Second Floor |
| 775 | Fourth Floor |
| 776 | Sofa Set 3+1+1 Providing & fixing Sofa Set 3+1+1 Brown and Cream leather DIMENSION Length: 182.5 (cms) Breadth (cms): 100 (cms)Height (cms): 100 (cms) Weight (Kilograms): 66 (Kilogram) Seating Capacity: Five Seat |
| 777 | Ground Floor |
| 778 | First Floor |
| 779 | Second Floor |
| 780 | Third Floor |
| 781 | Fourth Floor |
| 782 | Fifth Floor |
| 783 | Free Standing Table @ 1200Lx600Dx750HT Providing and fixing Table of Size 1200 x 600 x 750 mm. Top: made from 25 mm Prelaminated Particle board. All edges are covered by 2 mm. Thk. PVC edge bands glued by hot melt glue applied by auto edge banding machine. Legs : C Shape made from CRCA Sheet with Powder Coat finish. Modesty panel : Made from 18mm both side prelaminated particle boards.All edges are covered by 0.8mm PVC edge bands glued by hot melt glue applied by auto edge banding machine.KEYBOARD TRAY ( WITHOUT MOUSE TRAY ) :- Metal Powder Coated - Black Color, CPU TROLLEY :- Metal Powder Coated - Black Color, 3 DRAWER PEDESTAL UNIT having overall size 392L x 450D x 680Ht. mm. with central lock and key. Drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminated particle board, |
| 784 | Ground Floor |
| 785 | Second Floor |
| 786 | Third Floor |
| 787 | Fourth Floor |
| 788 | Fifth Floor |
| 789 | Executive Table @ 2250Lx2100Dx750HT including Low Height Credestal @ 1200Lx450Dx650HT Providing & Fixing of Table @ 2250Lx2100Dx750HT TOP & GABLE END to be made of Membrane finish with soft water fall edges & curved panel & Decorated Anodized section MODESTY PANEL to be made of 18 mm thick Prelaminated particle board with PVC edge band. INCLUDING CREDESTAL @ 1200L X 450D X 650H :- To be made out of Membrane Finish ( 2 Openable Shutter & 3 Drawer Pedestal in between ) as per drawing. |
| 790 | First Floor |
| 791 | Second Floor |
| 792 | Third Floor |
| 793 | Fourth Floor |
| 794 | Fifth Floor |
| 795 | Executive's Table @ 1800Lx900Dx750HT Providing & Fixing of Table @ 1800Lx900Dx750HT - TOP & GABLE END to be made of Membrane finish with soft water fall edges & curved panel & Decorated Anodized section MODESTY PANEL to be made of 18 mm thick Prelaminated particle board with PVC edge band as per drawing |
| 796 | Ground Floor |
| 797 | First Floor |
| 798 | Second Floor |
| 799 | Third Floor |
| 800 | Fourth Floor |
| 801 | Fifth Floor |
| 802 | Single Bed @ 2025LX 1000DX 650H Providing and fixing Single Bed of Size 2025Lx1000Dx650H with matress and pillow. Understructure: - The legs are made of Square tube of size 25 x 25mm made out of MS with a thickness of 1.2 mm. The legs should have corner brackets welded to it at two levels. The corner brackets are made of 2mm thick CRCA having a L shaped structure to join the side panels and headboard to the leg. Three nos. of Horizontal stiffeners are provided at equal intervals. The stiffeners are made of Square tube of size 25 x 25mm made out of MS with a thickness of 1.2mm. The middle Horizontal Stiffener has a leg attached to it to transfer the load to the ground and add to the strength and stability of the complete structure. This leg is also made of Square tube of size 25 x 25mm made out of MS with a thickness of 1.2mm. All Metal components to undergo 7 tank treatment process and should be powder coated to the thickness of minimum 50 Microns DFT.Side Panel: - The side panels are made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The overall width of the side panel is 150mm. The side panels have 18mm thick prelam particle board Baton running for required length to add rigidity to the structure. Head Board :- The head board is made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The head board size to be considered as 1000 x 650mm. Foot Board :- The foot board is made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The head board size to be considered as 1000 x 450mm. Bed Base: - The Bed Base is made up of 12mm thick Prelam Particle Board with both side White laminate. |
| 803 | Ground Floor |
| 804 | Third Floor |
| 805 | Fourth Floor |
| 806 | Fifth Floor |
| 807 | Bed Side Table @ 400LX 400DX 415H Providing and Fixing Bed Side Table of size 400LX 400DX 415H The bed side unit is made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The bed side table has one drawer and one shelf. The shelf is made of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding |
| 808 | Ground Floor |
| 809 | Third Floor |
| 810 | Fourth Floor |
| 811 | Fifth Floor |
| 812 | Providing and fixing in position partition (of size 3.0 m. x 3.0 m.) with supporting system made of 2\\"x2\\" thick ply stripes (Providing @ 2 C/C in both direction) made up of 18 mm plywood, both side covered with 12 mm ply of approved quality make (Century, Commander, Biz, royal forest grajan/ any other equivalent MR grade moisture resistance i.e. commercial ply etc.) including both sides covered with 1.5 mm laminate as per selection including all necessary hardware, fevicol etc. as per detailed drawing and design attached including cost of all material, leads, labours, necessary fixtures and fastening, painting etc. complete and as directed by Engineer in charge |
| 813 | First Floor |
| 814 | Second Floor |
| 815 | Third Floor |
| 816 | Fourth Floor |
| 817 | Fifth Floor |
| 818 | Providing and fixing in position Storage having depth 18\\" fixed (full height unit of size 2.1 m. L x 0.45 m. W x 2.1 m. H) with supporting system made up of 18 mm plywood, top 1.5\\" thick made with 18 mm ply, quality make (Century, commander, Biz, royal forest, Grajan / any other requivalent MR grade moisture resistance ie commercial ply etc.) including all exposed and unexposed surfaces covered with 1.5 mm laminate per selection including all necessary hardware, fevicol, handles, patch locks, drawer locks, hinges etc. as per detailed drawing and design attached including cost of all mateiral, lead, labours, necessary fixtures, and fastening, lead/ zinc based oil paint in 3 coats painting etc. complete and as directed by Engineer in charge |
| 819 | Ground Floor |
| 820 | First Floor |
| 821 | Second Floor |
| 822 | Third Floor |
| 823 | Fourth Floor |
| 824 | Fifth Floor |
| 825 | Providing and fixing table Forcabin (2.50 m. L x 0.90 m. B x 0.75 m. H) in position with supporting system made up of 18 mm plywood, quality make (Century, commander, Biz, royal forest Grajan / any other eequivalent MR grade moisture resistance i.e. commercial ply etc.) (Providing provision for 2 drawers and key board drawer, side storage box), top having thickness 1.5\\" which is finished with Korian material including all exposed surfaces covered with 4 mm thick veneer (with premium range with veneer has melamine polishing with PU coat finish) and all unexposed surfaces covered with 1.5 mm thick laminate including all necessary hardwares, fevicol, handles, patch locks, drawer locks, hinges etc. as perdetailed drawing and design attached including cost of all material, lead, labours, necessary fixtures and fastening, painting etc. complete and as directed by Engineer in charge |
| 826 | Ground Floor |
| 827 | First Floor |
| 828 | Second Floor |
| 829 | Third Floor |
| 830 | Fourth Floor |
| 831 | Fifth Floor |
| 832 | Providing and fixing table in position (with size 1.50 m. L x 0.75 m. B x 0.75 m. H) (at P.A. and Assist officer cb) with supporting system made up of 18 mm plywood top with 18 ply quality makde (century, Commander, Biz, royal forest grajan/ any other equivalent MR grade moisture resistance i.e. commercial ply etc.) incluidng exposed surfaces covered with 4 mm thick veneer (with economical range with veneer has melamine polishing with mat coat finish) and unexposed surfaces covered with 1.5 mm thick laminate as per selection, providing table top 12 mm thick glass fixed with S.S. stud, including all necessary hardware, fevicol, handles, patch locks, drawer locks, hinges etc. as per detailed drawing and design attached including cost of all materials, lead, labours, necessary fixtures, fastening, painting etc. complete and as ditected by Engineer in charge |
| 833 | Ground Floor |
| 834 | First Floor |
| 835 | Second Floor |
| 836 | Third Floor |
| 837 | Fourth Floor |
| 838 | Fifth Floor |
| 839 | 3 DRAWER PEDESTAL UNIT @ 392L x 450D x 680Ht. mm. 3 DRAWER PEDESTAL UNIT having overall size 392L x 450D x 680Ht. mm. with central lock and key. 3 Drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminated particle board. |
| 840 | Ground Floor |
| 841 | First Floor |
| 842 | Second Floor |
| 843 | Full Height Steel Storage @ 750Lx450Dx2100HT Providing and fixing Openable Steel Storage of 750 x 450 x 2100Ht, with 4 adjustable shelves, Complete body & shutter made in 0.8 mm thick & Top in 2 mm thick CRCA, 4 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns as as per drawing. |
| 844 | Ground Floor |
| 845 | First Floor |
| 846 | Second Floor |
| 847 | Third Floor |
| 848 | Fourth Floor |
| 849 | Fifth Floor |
| 850 | Alluminium foldable ladder for store Providing & Fixing Foldable Alluminum Ladder 1500 mm. Ht. |
| 851 | Ground Floor |
| 852 | First Floor |
| 853 | Second Floor |
| 854 | Third Floor |
| 855 | Fourth Floor |
| 856 | Fifth Floor |
| 857 | Free Standing Table @ 1500Lx600Dx750HT Providing and fixing Table of Size 1500 x 600 x 750 mm. Top: made from 25 mm Prelaminated Particle board. All edges are covered by 2 mm. Thk. PVC edge bands glued by hot melt glue applied by auto edge banding machine. Legs : C Shape made from CRCA Sheet with Powder Coat finish. Modesty panel : Made from 18mm both side prelaminated particle boards.All edges are covered by 0.8mm PVC edge bands glued by hot melt glue applied by auto edge banding machine.KEYBOARD TRAY ( WITHOUT MOUSE TRAY ) :- Metal Powder Coated - Black Color, CPU TROLLEY :- Metal Powder Coated - Black Color, 3 DRAWER PEDESTAL UNIT having overall size 392L x 450D x 680Ht. mm. with central lock and key. Drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminated particle board, |
| 858 | Ground Floor |
| 859 | First Floor |
| 860 | Second Floor |
| 861 | Third Floor |
| 862 | Fourth Floor |
| 863 | Fifth Floor |
| 864 | Stool for Lab and Class-IV Providing and fixing 4 legged Lab stool, Legs made of 16 Guage 45 MM Outer dimension MS Pipe, Duly painted, With a 304 Grade Stainless steel 12 inch wide seat with a 1 inch collar, Height adjustment via a screw. as per design and drawing and instructions of Engineer in charge. |
| 865 | Ground Floor |
| 866 | Providing and fixing wall panelling of size 3.0 m. x 3.0 m. x 3\\" thick with supporting system made of 1.5\\" x 1.5\\" thick ply etc. complete |
| 867 | Ground Floor |
| 868 | First Floor |
| 869 | Second Floor |
| 870 | Third Floor |
| 871 | Fourth Floor |
| 872 | Fifth Floor |
| 873 | Dismantling stone masonry in lime or cement mortar including stacking the materils as directed with all leads, lifts etc. |
| 874 | Dismantling the R.C.C. Work 1:2:4 and sorting out the materials such as steel etc. as directed and stacking them within the specified lead as directed etc. complete. |
| 875 | Dismantling brick masonry in lime or cement mortar and stacking the materils as directed with all leads, lifts etc. |
| 876 | Removing lime or lean cement concrete including stacking the spoils as directed with all leads, lifts etc, complete. |
| 877 | Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. complete |
| 878 | Removing brick bat coba including stacking the spoils as directed with all leads, lifts etc, complete. |
| 879 | Removing doors and windows with frames and stacking the materials as directed with all leads, lifts etc. complete. |
| 880 | Removing ventilators and small windows with frame and stacking the materials with all leads, lifts etc. complete. |
| 881 | Removing urinal pans or wash hand basins with frame including disconnecting the sanitary and water supply connections, removing the same carefully and stacking the serviceable materials as and where directed including throwing the unserviceable materials outside etc complete |
| 882 | Removing W.C. pans including disconnecting the sanitary and water supply connections, removing and breaking flooring and bed con-crete around pan removing the same carefully and stacking the serviceable materials as adn where directed including throwing the unserviceable materiasls out side etc. carefully and throwing out the refusal outside etc. complete. |
| 883 | Removing G.I. or A.C. sheet roofing including purlins, principal rafters etc. including sorting serviceable and unserviceable materials, stacking the same as and where directed in the compound including scaffolding etc. complete. |
| 884 | (b) Work Portion _ Electrical |
| 885 | Estimate No : 213007-1 of 2024-2025-Providing Transformer & DG set for the Proposed Krushi Bhavan Admin Building & Laboratory Building at Shahanpur Miya Dargah Dist. Chhatrapati Sambhaji Nager. (Subwork 1) |
| 886 | Supplying and erecting four pole ON LOAD change over switch 415V 315-320A open execution having staggered termination phase barrier shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit operational current category AC23A complying to IS/IEC 60947-3 Part-1/3. [5-1-7] |
| 887 | Providing and erecting 4 Pole MCCB 415V 250A rated short-circuit breaking capacity 36 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides with insulation withstand capacity 800V no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB [5-5-3] |
| 888 | Providing and erecting 4 Pole MCCB 415V 400A rated short-circuit breaking capacity 36 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides with insulation withstand capacity 800V no line-load bias in provided enclosure /panel as per specification no. SW-SWR/MCCB [5-5-4] |
| 889 | Supplying, installing, testing and commissioning of extendable/non-extendable indoor type 11 kV 630A load break switch compliant to IEC 62271 -100 200 and 102 on provided MS channels/trench/foundations per specification no SW-HTS / LBS [5-9-1] |
| 890 | Supplying and erecting SS enclosure for MCCB suitable for above 250 A up to 800A MCCB. [5-11-19] |
| 891 | Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes panel boards etc. including cutting bending drilling welding riveting treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete. [6-1-1] |
| 892 | Supplying and erecting iron work sheet metal work consisting of CRCA sheets various sections of iron plates chequered plates rods bars MS pipes etc. for panel board or any other purpose with bending cutting drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. [6-1-19] |
| 893 | Supplying and erecting of any size electrolyte aluminium patti or bar in bus bar chamber / in panel or any other purpose 500 V with require capacity 99.9% aluminium purity with E91E Grade as per IS 5082 & Current Density 0.8 A per sq. mm. with fixing arrangement (like lug or bottle type lug) to both the end with high grade polyolefin insulation sleeve complete as per specification no. BCP-BB [6-2-11] |
| 894 | Supplying, erecting, testing and commissioning of 11KV HT metering cubical (compact / vertical type) approved by MSEDCL / licensee fabricated with 2 mm (14 SWG) M.S. sheets with supporting angle painted with powder coating / epoxy paint of required shade copper bus bar size 25 x 6 mm heavy duty mechanical lock with counter meter for measuring no of times the opening of meter door top side cover (CT PT cover) interlock with meter door epoxy casted 3 nos. CT having required ratio between 10/5A to 50/5A VA10 or 15 Class 0.5S epoxy casted 3 nos. PT having ratio 11000/V3/110/V3 VA 50 Class 0.5 suitable for provided trivector meter and provision for incoming and outgoing cables complete duly tested by licensee with necessary test certificates and erected on provided plinth/ cc foundation. [6-4-1] |
| 895 | Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½core 240 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-23] |
| 896 | Supplying, erecting & terminating XLPE insulated galvanised steel formed wire armoured (strip) cable 11 kV(UE) 3 x 95 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT [7-3-9] |
| 897 | Providing and erecting Heat shrinkable indoor termination kit for 11 kV ( E ) XLPE HT cable 3x up to 95 sq. mm. with necessary material as per specification no. CB-JT/HT [7-5-1] |
| 898 | Providing and erecting Heat shrinkable out door termination kit for 11 kV ( E ) XLPE HT cable 3 x up to 95 sq. mm. with necessary material as per specification No. CB-JT/HT [7-5-5] |
| 899 | Supplying and erecting G.I. pipe ‘A’ class 75 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE [7-6-4] |
| 900 | Supplying and laying (including excavation) half round reinforced cement concrete pipe of IS 458 2003 NP-2 class of 150 mm internal diameter in proper line level and slope including providing and fixing collars in cement mortar 1 2 and curing etc. complete. [7-6-6] |
| 901 | Supplying and laying (including excavation) of suitable width & depth up to 90 cm) 120 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface to required depth complete. [7-6-12] |
| 902 | Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials testing & recording the results as per specification no. EA-EP [9-1-1] |
| 903 | Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials testing & recording the results as per specification no. EA-EP [9-1-2] |
| 904 | Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EA-EP. [9-2-2] |
| 905 | Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. [9-2-3] |
| 906 | Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete. [9-2-5] |
| 907 | Supplying, installing, testing and commissioning of 3 phase 11/0.433 kV 50 Hz. 315 kVA Mineral oil immersed and naturally cooled outdoor type Copper wound Non-sealed transformer delta/star connected with additional neutral brought out on load side temperature rise should not exceed 45? by thermometer in oil and 50? by the resistance method in winding at full load rating using type A winding insulation (kraft paper) with HV tapping (with off load tap changer) off load +5 to -10 in steps of 2.5% +5 to -10 in steps of 2.5% having 7 number of tap positions with standard accessories complete with test certificate with losses below 1025 Watts at 50% load 3100 Watts at 100% load as per IS 1180 (part 1) 2014 with necessary permissions of Electrical Inspector as per specification no SS- TR-NSL. [10-1-7] |
| 908 | Supplying and erecting fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work erected in CC foundation and painted complete as per specification no SS-AS/FSG [10-6-18] |
| 909 | Supplying and erecting 50 x 50 x 6 mm angle iron as corner support 2m long fixed at the middle of the fencing frame and the other side inclined at 30 degree angle in cement concrete foundation of 15 x 15 x 40 cm complete duly painted with one coat of red oxide and two coats aluminium paint complete. [10-6-19] |
| 910 | Supplying and erecting double leaf hinged door each 1500 mm in width x 1850 mm in height using B class GI pipe with angle iron supports chain link wire mesh (jali) complete supported on channel iron erected in foundation and painted complete as per specification no SS-AS/DLD [10-6-20] |
| 911 | Supplying and fixing PVC synthetic elastomer electrically insulating mat with class A insulation conforming to IS 15652 – 2006 having 2 mm thickness up to 3.3 kV [10-6-25] |
| 912 | Supplying, erecting, testing and commissioning of diesel generating set with alternator of 200 kVA output continuous rating 3 Phase 415 V 50c/s 0.8 p. f. A.C supply a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours along with standard accessories self-excited self-regulated screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 % with performance class G2 and maximum fuel consumption 34.40 Ltr/hr 75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters switchgears indicators connected with suitable wires/cables the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet sound absorbing material to restrict sound level up to 75 dB(A) at 1.0 m provided with first filling of oil diesel not less than 300 Ltr etc. on provided M20 Grade CC Foundation as per specification no. GEN-DG [11-1-17] |
| 913 | Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 200 kVA up to 250 kVA capacity Three phase 415 Volts 50Hz A.C. with all standard features safeties etc as per specification no. GEN-AMF. (with note of 10% rate reduction) [11-2-15] |
| 914 | Supplying, installing, testing and commissioning of FR XLPE armoured cable 4 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU [13-9-11] |
| 915 | Excavating hard Rock or bituminous road by chiselling for preparing pit for pole / stay/earth plate / for laying cable/ pipe & clearing the site by removing debris & making the site as required complete. [16-1-5] |
| 916 | Supplying and spreading stone metal 25 mm size for 100 mm depth above the ground level complete. [16-2-3] |
| 917 | Making transformer plinth (1.5 x 1.5 x 1.5) m in size with necessary excavation in ground with 150 mm. thick M- 10 PCC at the bottom and top and 250 mm. thick burnt brick wall constructed at periphery and remaining hollow portion shall be filled with 40mm hard broken aggregate. External surface duly plastered by 12 mm thick including watering etc complete. [16-3-1] |
| 918 | Making cement concrete foundation in 1 3 6 cement concrete (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose).(7.3*4.74*1.5Mtr. =51.90) [16-3-7] |
| 919 | Estimate No : 213007-2 of 2024-2025-Providing Internal Electrification System for the Proposed Krushi Bhavan Admin Building at Shahanpur Miya Darga Dist. Chhatrapati Sambhaji Nager.(Subwork 2) |
| 920 | Supplying and erecting HMS PVC conduit FRLS grade 20 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No WG-MA/CC [1-1-7] |
| 921 | Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No WG-MA/CC [1-1-9] |
| 922 | Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No WG-MA/CC [1-1-11] |
| 923 | Supplying and erecting 25 mm dia. corrugated flexible polypropylene conduit [1-2-2] |
| 924 | Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No WG-MA/BW [1-3-1] |
| 925 | Supplying and erecting green colour earthing with 1x 1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No WG-MA/BW [1-3-1] |
| 926 | Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-2] |
| 927 | Supplying and erecting green colour earthing with 1x 2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-2] |
| 928 | Supplying and erecting green colour earthing with 1x 4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-3] |
| 929 | Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-3] |
| 930 | Supplying and erecting green colour earthing with 1x 6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-4] |
| 931 | Supplying and erecting mains with 4x 6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-4] |
| 932 | Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. [1-6-1] |
| 933 | Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete. [1-6-2] |
| 934 | Supplying and erecting modular type bell-push 6A / 10A duly erected on provided plate and box with wiring connections complete. [1-6-3] |
| 935 | Supplying and erecting modular type 3 pin 6A multi socket with safety shutter duly erected on provided plate and box with wiring connections complete. [1-6-10] |
| 936 | Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter duly erected on provided plate and box with wiring connections complete. [1-6-11] |
| 937 | Supplying and erecting modular type telephone socket one gang with safety shutter duly erected on provided plate and box with wiring connections complete. [1-6-15] |
| 938 | Supplying and erecting modular type computer Jack RJ45 with safety shutter duly erected on provided plate and box with wiring connections complete. [1-6-17] |
| 939 | Supplying and erecting modular type buzzer 220 / 250V duly erected on provided plate and box with wiring connections complete. [1-6-19] |
| 940 | Supplying and erecting modular type (two module) electronic step regulator for fan duly erected on provided plate and box with wiring connections complete. [1-6-23] |
| 941 | Supplying and erecting modular type blanking plate one module duly erected on provided plate & box. [1-6-24] |
| 942 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. [1-6-34] |
| 943 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. [1-6-35] |
| 944 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. [1-6-36] |
| 945 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. [1-6-40] |
| 946 | Supplying and erecting modular pop up Box 8 module erected with provided AV/ HDMI RJ 45 6 A electrical sockets and switch on provided table. [1-6-58] |
| 947 | Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires modular type switch earthing and required accessories as per specification No WG-PW/CW [1-7-5] |
| 948 | Point wiring for ceiling fan concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires modular type switch earthing and required accessories as per specification No WG-PW/CW [1-7-6] |
| 949 | Point wiring for light/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires modular type switch earthing and required accessories as per specification No WG-PW/HW [1-7-15] |
| 950 | Wiring for plug on board with Switch socket surface/concealed type copper wiring and earthing and with modular accessories as per specification No WG-PW/CW [1-7-26] |
| 951 | Supplying and erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation polyester taped Nylon Rip Cord & grey colour sheathed with FR PVC conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW [1-8-1] |
| 952 | Supplying and erecting 5 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation polyester taped Nylon Rip Cord & grey colour sheathed with FR PVC conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW [1-8-4] |
| 953 | Supplying and erecting 10 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation polyester taped Nylon Rip Cord & grey colour sheathed with FR PVC conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW [1-8-5] |
| 954 | Supplying and erecting 50 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation polyester taped Nylon Rip Cord & grey colour sheathed with FR PVC conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW [1-8-7] |
| 955 | Supplying and erecting co-axial copper cable low voltage grade tri-shielded RG-11 as per specification No. WG-TW [1-8-18] |
| 956 | Supplying and erecting 3m HDMI cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete. [1-8-21] |
| 957 | Supplying and erecting 5m HDMI cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete. [1-8-22] |
| 958 | Supplying, Erecting and Commissioning of MDF Box 50x50 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TW [1-9-1] |
| 959 | Supplying, Erecting and Commissioning of 50 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TW [1-9-15] |
| 960 | Supplying, Erecting and Commissioning of 10 pair module for connection & disconnection of telephone cable as per specification no. WG-TW [1-9-18] |
| 961 | Supplying, Erecting and Commissioning of digital (hybrid) type EPABX of 6 x 32 extensions suitable upto 96 extensions complete. Add Rs. 38159.00 for additional 16 extension card for digital (hybrid) typeEPABX2) Add Rs. 19032.00 for additional 8 extension card for digital (hybrid) typeEPABX [1-9-26] |
| 962 | Supplying, Erecting and Commissioning of push button telephone instrument desk top unit as per specification complete [1-9-28] |
| 963 | Supplying, Erecting and Commissioning of IP telephone instrument as per specification complete. [1-9-30] |
| 964 | Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC [1-10-1] |
| 965 | Supplying and erecting LSZH armoured multimode optical fibre cable with 6 fibres core dia 50/125 µm (OM3) suitable upto 10 GBPS ethernet distance at 850 nm of wavelength on wall/ceiling or laid in provided pipe/trench as per specification no. WG-COC/OFC LSZH [1-10-8] |
| 966 | Supplying and fixing 1 m UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC [1-10-16] |
| 967 | Supplying and installing single mode simplex pigtail with SC/LC splicing complete. [1-10-27] |
| 968 | Supplying, fixing, and configuring 24 ports with 4 (SFP+) port ethernet managed switch with web view/CLI 6KV surge protection on ethernet port and console port for management in provided rack as per specification no. WG-NWC/GBS [1-11-4] |
| 969 | Supplying, fixing, and configuring 10G Base -SR (SFP+) simplex MM transceiver erected in provided rack complete. [1-11-15] |
| 970 | Supplying, fixing, and configuring modularised multi-service router 802.11/a/n/ac unified Wave 2.5 GHz with RJ-45 port supporting 1 to 13 channels for 2.4 GHz with unified wireless access point complete. [1-11-18] |
| 971 | Supplying, installing & testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC. [1-12-1] |
| 972 | Supplying and fixing tool-less IO (Ethernet) flush/surface type in provided modular box as per specification no. WG-NAS/IO [1-12-2] |
| 973 | Supplying and fixing tool-less shutter keystone jack (RJ-45) in provided patch panel complete as per specification no. WG-NAS/KJ [1-12-3] |
| 974 | Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP [1-12-4] |
| 975 | Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 500x600x367 mm) as per specification No. WG-NAS/RAK [1-12-17] |
| 976 | Supplying and fixing 9U wall mount rack (Dimension-DxWxH – 500x600x500 mm) as per specification No. WG-NAS/RAK [1-12-18] |
| 977 | Supplying and fixing 36U floor mount server rack (Dimension-DxWxH – 800x600x1600 mm) as per specification No. WG-NAS/RAK [1-12-26] |
| 978 | Supplying and erecting LED square / circular Max. 7W down lighter/ Panel Light having pressure die-cast aluminium housing polystyrene diffuser having system lumens output of Min. 770 Lumens min. efficacy of 110 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. max. ripple of 5% THD<10% p.f. >0.95 operating range of 120-270V surge protection of 2.5 kV Life class of 50 000 Hrs. at L70B50 including driver having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. [2-1-2] |
| 979 | Supplying and erecting LED square / circular Max. 14 W down lighter/Panel Light having pressure die-cast aluminium housing polystyrene diffuser having system lumens output of Min. 1500 Lumens min. efficacy of 110 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. max. ripple of 5% THD<10% p.f. >0.95 operating range of 120-270V surge protection of 2.5 kV Life class of 50 000 Hrs. at L70B50 including driver having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. [2-1-4] |
| 980 | Supplying and erecting LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing polystyrene diffuser having system lumens output of Min. 2000 Lumens min. efficacy of 110 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. max. ripple of 5% THD<10% p.f. >0.95 operating range of 120-270V surge protection of 2.5 kV Life class of 50 000 Hrs. at L70B50 including driver having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. [2-1-5] |
| 981 | Supplying and erecting LED Panel Light(600mm X 600mm) Max. 30 W having CRCA powder coated housing polystyrene diffuser having system lumens output of Min. 3600 Lumens min. efficacy of 120 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. max. ripple of 5% THD<10% p.f. >0.95 operating range of 120-270V surge protection of 2.5 kV Life class of 50 000 Hrs. at L70B50 including driver having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. [2-1-7] |
| 982 | Supplying and erecting LED Strip light 5m Length Max. 95 W IP20 class having minimum lumens output of 1600 Lumens/m min. efficacy of 90 lumen/W CRI>80 CCT upto 5000K Beam Angle of 110 deg. THD<10% p.f. >0.95 operating range of 230-270V Life class of 30 000 Hrs. at L70B50 including driver with 1 year warranty. [2-1-11] |
| 983 | Supplying LED concealed type foot / step light with aluminium body for indoor/outdoor application suitable for 4W-6W LED including driver and erecting by making necessary arrangement / recess in wall to make it flush with surface with 1 year warranty. [2-1-12] |
| 984 | Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens min. efficacy of 110 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. THD<10% p.f. >0.95 operating range of 140-260V in built surge protection of 2.5 kV Life class of 50 000 Hrs. at L70B50 including driver IP66 IK09 rated on provided PVC Block / wooden board with 3 years warranty. [2-1-15] |
| 985 | Supplying and erecting anodized aluminium corridor / passage / mirror light LED fitting (2 feet) Max. 12W with high transitivity diffuser with min. system lumens output of 1200 lumens min. efficacy of 100 lumen/W CRI>80 CCT upto 6000K Beam Angle of 110 deg. Ripple<5% THD<10% p.f. >0.95 operating range of 200-270V surge protection of 2 kV Life class of 50 000 Hrs. at L70B50 including driver with end caps on provided PVC Block / wooden board with 3 years warranty. [2-1-16] |
| 986 | Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens min. efficacy of 100 lumen/W CRI>80 CCT upto 6000K Beam Angle of 110 deg. Ripple<5% THD<10% p.f. >0.95 operating range of 200-270V surge protection of 2 kV Life class of 50 000 Hrs. at L70B50 including driver with end caps on provided PVC Block / wooden board with 3 years warranty. [2-1-18] |
| 987 | Supplying and erecting inverter LED batten 20W tube light fitting with polycarbonate housing heat sink integrated HF electronic driver Min. 2600 mAh Lithium ion Battery with charging time of 8-10 Hours and backup time of Min. 3 hrs. with minimum 25% of initial Watts having luminous efficacy of 100 lumen/watt CRI>80 CCT of 6500K and THD<=20% having useful life of minimum 25000 hrs. with overheating protection with 2 years warranty. [2-1-22] |
| 988 | Supplying and erecting Electronic type cordless call bell erected on T.W. board having portable bell push working on 9V D.C. battery and (effective range upto 45 meter) bell on 250 V A.C. supply. [2-3-15] |
| 989 | Supplying and erecting regular/ standard model ceiling fan of 600mm. sweep complete erected in position as per specification no. FG-FN/CF [2-10-1] |
| 990 | Supplying and erecting bracket fan 400 mm. sweep A. C. 230 volts 50 cycles 1350 RPM. Oscillating type plastic or metal blades chrome plated guard with speed regulator and moisture proof treatment to winding and with ‘E’ class insulation. [2-10-4] |
| 991 | Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 300mm. 1400 RPM rust proof body & blades wire mesh duly erected complete. [2-10-13] |
| 992 | Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm max. energy consumption of 28W having service ratio (CMM/W) of Min. 8 PF>0.9 THD<10% with IR remote control/compatible speed regulator Temperature Rise of Max. 40 deg. C having external mounted control PCB completely erected in position as per specification no. FG-FN/CF [2-10-22] |
| 993 | Supplying and erecting fan hook box of 10 mm M.S. round bar bounded to the R.C.C. bars upto 50 mm length each side and pierced through a 16 S.W.G. thick aluminium/M.S. Bowl 100 mm dia. or equivalent square size and having depth upto 75 mm complete erected with duly painted by one coat of red oxide paint and two coats of paint erected in position and without any leakage of slurry of cement concrete on either side of the box and positioned to the bottom level of the slab. [2-11-5] |
| 994 | Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire. [2-11-6] |
| 995 | Supplying, erecting, testing and commissioning of self contained water cooler 230/250V 50Hz nominal cooling capacity of 80 litres per hour and storage capacity 120 litres with partially stainless steel body as per specification no. AP-WCR/WC22 [3-3-9] |
| 996 | Supplying and erecting ultra violet storage type water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps with output of purified water minimum 0.33 litre/min with activated carbon filter and softener operating on 230V single phase A.C. supply with UV fail & filter change indication system .(for TDS more than 200) [3-5-1] |
| 997 | Supplying, installing, testing and commissioning of 3kVA capacity online pure sine wave with backup time of .30 Min. PWM & IGBT based UPS with 0.8 to unity output pf single phase input & 1 phase output complete with all protections as per specification no. AP-UPS [3-7-3] |
| 998 | Supplying, installing, testing and commissioning of 6kVA capacity online pure sine wave with backup time of 30 Min. PWM & IGBT based UPS with 0.9 to unity output pf single phase input & 1 phase output complete with all protections as per specification no. AP-UPS [3-7-4] |
| 999 | Supplying and erecting 12V/17Ah -18Ah SMF battery with battery terminal wire duly charged with 12 months warranty complete [3-8-8] |
| 1000 | Supplying and erecting 12V/26Ah SMF battery with battery terminal wire duly charged with 24 months warranty complete [3-8-9] |
| 1001 | Supplying, erecting and marking SPMCB 6A to 32A C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-2] |
| 1002 | Supplying, erecting and marking SPMCB 6A to 32A B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-3] |
| 1003 | Supplying, erecting and marking DPMCB 6A to 32A C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-6] |
| 1004 | Supplying, erecting and marking TPMCB 6A to 32A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-10] |
| 1005 | Supplying, erecting and marking TPMCB 40A to 63A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-11] |
| 1006 | Supplying, erecting and marking FPMCB 6A to 32A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-12] |
| 1007 | Supplying, erecting and marking FPMCB 40A to 63A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-13] |
| 1008 | Supplying and erecting triple pole and neutral distribution board (TPNDB) SPMCB of 4 ways/phase (12 poles) with door 1.2mm thickness surface/flush mounted IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB [5-4-1] |
| 1009 | Supplying and erecting triple pole and neutral distribution board (TPNDB) SPMCB of 8 ways / phase (24 poles) with door 1.2mm thickness surface/ flush mounted IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB [5-4-2] |
| 1010 | Supplying and erecting single pole and neutral distribution board (SPNDB) with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs with door 1.2mm thickness surface / flush mounted IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB [5-4-8] |
| 1011 | Supplying and erecting single pole and neutral distribution board (SPNDB) with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs with door 1.2mm thickness surface / flush mounted IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB [5-4-9] |
| 1012 | Supplying and erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame. [5-4-13] |
| 1013 | Supplying and erecting triple pole and neutral distribution board (TPNDB) 3 pole/4 pole MCCB as incomer & outgoing SP MCB (24 poles) or TP MCB of 8 ways (24 poles) with door 1.2mm thickness surface/flush mounted on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1 [5-4-16] |
| 1014 | Providing and erecting 4 Pole MCCB 415 V 100A rated short-circuit breaking capacity 25 kA (Ics=100% of Icu) adjustable thermal (overload) setting and fixed magnetic setting with provided leads provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides insulation withstand capacity 800V no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB [5-5-1] |
| 1015 | Providing and erecting 4 Pole MCCB 415V 200A rated short-circuit breaking capacity 25 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides with insulation withstand capacity 800V no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB [5-5-2] |
| 1016 | Providing and erecting 4 Pole MCCB 415V 250A rated short-circuit breaking capacity 36 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides with insulation withstand capacity 800V no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB [5-5-3] |
| 1017 | Supplying, Erecting and Commissioning of 2 pole RCCB 16/25A electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB [5-6-1] |
| 1018 | Supplying, Erecting and Commissioning of 4 pole RCCB 16/25A electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB [5-6-4] |
| 1019 | Supplying, Erecting and Commissioning of 4 pole RCCB 40A electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB [5-6-5] |
| 1020 | Supplying, Erecting and Commissioning of 4 pole RCCB 63A electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB [5-6-6] |
| 1021 | Supplying, fixing, and commissioning 2 pole RCBO 6/10/16/20/25A with overcurrent rated short-circuit breaking capacity (10 kA) and earth leakage protection with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO [5-6-9] |
| 1022 | Supplying and erecting porcelain/epoxy bus bar support complete erected in provided M.S. box for 200/300A [5-10-27] |
| 1023 | Supplying and erecting terminal spreaders suitable for 4 pole above 100A up to 250A MCCB (Set of 8) [5-11-7] |
| 1024 | Supplying and erecting earth fault module for MCCB with adjustable earth fault sensitivity selection 10% to 50% of nominal current (In) and adjustable time delay 100/200 millisecond suitable for above 200A up to 400A MCCB with inbuilt CTs. [5-11-12] |
| 1025 | Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes panel boards etc. including cutting bending drilling welding riveting treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete. [6-1-1] |
| 1026 | Supplying and erecting iron work sheet metal work consisting of CRCA sheets various sections of iron plates chequered plates rods bars MS pipes etc. for panel board or any other purpose with bending cutting drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. [6-1-19] |
| 1027 | Supplying and erecting of any size electrolyte aluminium patti or bar in bus bar chamber / in panel or any other purpose 500 V with require capacity 99.9% aluminium purity with E91E Grade as per IS 5082 & Current Density 0.8 A per sq. mm. with fixing arrangement (like lug or bottle type lug) to both the end with high grade polyolefin insulation sleeve complete as per specification no. BCP-BB [6-2-11] |
| 1028 | Supplying and erecting Intelligent flush mounted panel meter three phase four wire (IPM) input voltage measurement range 50-550 V AC (P-P) 415V aux. supply 90-300 V AC/DC flush mounted (96 x 96 mm) meter constant Wh viewing in LCD multifunction meters in auto scroll mode with voltage current frequency power factor kW kVA kVAR kWh kVAh kVARh phase angle interrupts THD complete with RS 485 communication protocol class 1 accuracy and wiring connections and mounting hardware on provided panels complete with calibration certificate from manufacturer. [6-3-9] |
| 1029 | Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates. [6-5-2] |
| 1030 | Supplying and erecting LED type indicating pilot lamp with LED colours red / yellow / green 230 / 250V on provided box / panel with necessary material wiring & connections etc. [6-5-5] |
| 1031 | Supplying and erecting LED type indicating pilot lamp with LED colour blue 230 / 250 V on provided box / panel with necessary material wiring & connections etc. [6-5-6] |
| 1032 | Supplying and erecting 75 kVAr 440 V 3 phase 50 Hz. Contactor Logic & Intelligent Relay micro APFC passive filter panel consisting of suitable steps of APP/MPP type capacitor units with Detuned (harmonic filter) reactors of suitable rating APFC panel shall be compliance to IEC 61439 and power quality IEC 61921 standard as per specification no CP-ED/APFC [6-7-4] |
| 1033 | Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 35 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-16] |
| 1034 | Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 95 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-19] |
| 1035 | Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 185 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-22] |
| 1036 | Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-29] |
| 1037 | Providing and erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 100 mm height comprising all required standard accessories. [7-11-1] |
| 1038 | Providing and erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 200 mm width & 100 mm height comprising all required standard accessories. [7-11-2] |
| 1039 | Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials testing & recording the results as per specification no. EA-EP [9-1-3] |
| 1040 | Providing earthing with copper earth plate size 60 x 60 x 0.315 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover with minimum 25 kg Carbon based environment friendly back fill Ground Enhancing compound complete with all materials testing & recording the results as per specification no ESE -LA [9-1-6] |
| 1041 | Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EA-EP. [9-2-2] |
| 1042 | Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. [9-2-3] |
| 1043 | Supplying and erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation complete. [9-3-1] |
| 1044 | Providing printed instruction chart for treating persons suffering from electric shock printed in English & Marathi and duly laminated complete. [10-6-22] |
| 1045 | Supplying standard first aid box with necessary antiseptic cream medicine for use on wounds due burn crepe bandage gauge bandage medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use scissors anti-septic solution etc. (All above contents shall be of standard makes) [10-6-24] |
| 1046 | Supplying and fixing PVC synthetic elastomer electrically insulating mat with class B insulation conforming to IS 15652 – 2006 having 2.5 mm thickness up to 11 kV [10-6-26] |
| 1047 | Supplying, erecting, testing and commissioning of 120 W amplifier suitable to operate on 230 Volts A.C. / 12 Volts D.C. supply complete as per specification no. FF-PA/AFR [13-11-1] |
| 1048 | Supplying, erecting, testing and commissioning of 15 to 30 Watts sound column or ceiling mounted complete as per specification no. FF-PA/SOC [13-11-2] |
| 1049 | Supplying, erecting, testing and commissioning of 1.5 sq. mm speaker wire complete. [13-11-10] |
| 1050 | EST. No. 213007 Providing 500 KVA Transformer & 300 KVA DG set for the Proposed Krushi Bhavan Admin Building at Shahanpur Miya Dargah Dist. Chhatrapati Sambhaji Nager.(Subwork 3) |
| 1051 | Supplying and erecting HMS PVC conduit FRLS grade 20 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No WG-MA/CC [1-1-7] |
| 1052 | Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No WG-MA/CC [1-1-9] |
| 1053 | Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No WG-MA/CC [1-1-11] |
| 1054 | Supplying and erecting 25 mm dia. corrugated flexible polypropylene conduit [1-2-2] |
| 1055 | Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No WG-MA/BW [1-3-1] |
| 1056 | Supplying and erecting green colour earthing with 1x 1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No WG-MA/BW [1-3-1] |
| 1057 | Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-2] |
| 1058 | Supplying and erecting green colour earthing with 1x 2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-2] |
| 1059 | Supplying and erecting green colour earthing with 1x 4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-3] |
| 1060 | Supplying and erecting mains with 4x 4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-3] |
| 1061 | Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-3] |
| 1062 | Supplying and erecting green colour earthing with 1x 6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-4] |
| 1063 | Supplying and erecting mains with 4x 6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-4] |
| 1064 | Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. [1-6-1] |
| 1065 | Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete. [1-6-2] |
| 1066 | Supplying and erecting modular type 3 pin 6A multi socket with safety shutter duly erected on provided plate and box with wiring connections complete. [1-6-10] |
| 1067 | Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter duly erected on provided plate and box with wiring connections complete. [1-6-11] |
| 1068 | Supplying and erecting modular type telephone socket one gang with safety shutter duly erected on provided plate and box with wiring connections complete. [1-6-15] |
| 1069 | Supplying and erecting modular type computer Jack RJ45 with safety shutter duly erected on provided plate and box with wiring connections complete. [1-6-17] |
| 1070 | Supplying and erecting modular type (two module) electronic step regulator for fan duly erected on provided plate and box with wiring connections complete. [1-6-23] |
| 1071 | Supplying and erecting modular type blanking plate one module duly erected on provided plate & box. [1-6-24] |
| 1072 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. [1-6-34] |
| 1073 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. [1-6-35] |
| 1074 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. [1-6-36] |
| 1075 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. [1-6-38] |
| 1076 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. [1-6-40] |
| 1077 | Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires modular type switch earthing and required accessories as per specification No WG-PW/CW [1-7-5] |
| 1078 | Point wiring for ceiling fan concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires modular type switch earthing and required accessories as per specification No WG-PW/CW [1-7-6] |
| 1079 | Point wiring for light/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires modular type switch earthing and required accessories as per specification No WG-PW/HW [1-7-15] |
| 1080 | Wiring for plug on board with Switch socket surface/concealed type copper wiring and earthing and with modular accessories as per specification No WG-PW/CW [1-7-26] |
| 1081 | Supplying and erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation polyester taped Nylon Rip Cord & grey colour sheathed with FR PVC conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW [1-8-1] |
| 1082 | Supplying and erecting 5 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation polyester taped Nylon Rip Cord & grey colour sheathed with FR PVC conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW [1-8-4] |
| 1083 | Supplying and erecting 10 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation polyester taped Nylon Rip Cord & grey colour sheathed with FR PVC conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW [1-8-5] |
| 1084 | Supplying and erecting 50 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation polyester taped Nylon Rip Cord & grey colour sheathed with FR PVC conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW [1-8-7] |
| 1085 | Supplying and erecting co-axial copper cable low voltage grade tri-shielded RG-11 as per specification No. WG-TW [1-8-18] |
| 1086 | Supplying and erecting 3m HDMI cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete. [1-8-21] |
| 1087 | Supplying and erecting 5m HDMI cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete. [1-8-22] |
| 1088 | Supplying and erecting HDMI Extender Over RJ45 Ethernet Cable Cat 6 60m/200ft complete. [1-8-28] |
| 1089 | Supplying, Erecting and Commissioning of MDF Box 50x50 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TW [1-9-1] |
| 1090 | Supplying, Erecting and Commissioning of 50 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TW [1-9-15] |
| 1091 | Supplying, Erecting and Commissioning of 10 pair module for connection & disconnection of telephone cable as per specification no. WG-TW [1-9-18] |
| 1092 | Supplying, Erecting and Commissioning of digital (hybrid) type EPABX of 6 x 32 extensions suitable upto 96 extensions complete. [1-9-26] |
| 1093 | Supplying, Erecting and Commissioning of push button telephone instrument desk top unit as per specification complete [1-9-28] |
| 1094 | Supplying, Erecting and Commissioning of IP telephone instrument as per specification complete. [1-9-30] |
| 1095 | Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC [1-10-1] |
| 1096 | Supplying and erecting LSZH armoured multimode optical fibre cable with 6 fibres core dia 50/125 µm (OM3) suitable upto 10 GBPS ethernet distance at 850 nm of wavelength on wall/ceiling or laid in provided pipe/trench as per specification no. WG-COC/OFC LSZH [1-10-8] |
| 1097 | Supplying and fixing 1 m UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC [1-10-16] |
| 1098 | Supplying, fixing, and configuring 24 ports with 4 (SFP+) port ethernet managed switch with web view/CLI 6KV surge protection on ethernet port and console port for management in provided rack as per specification no. WG-NWC/GBS [1-11-4] |
| 1099 | Supplying, fixing, and configuring 10G Base -SR (SFP+) simplex MM transceiver erected in provided rack complete. [1-11-15] |
| 1100 | Supplying, fixing, and configuring modularised multi-service router 802.11/a/n/ac unified Wave 2.5 GHz with RJ-45 port supporting 1 to 13 channels for 2.4 GHz with unified wireless access point complete. [1-11-18] |
| 1101 | Supplying, installing & testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC. [1-12-1] |
| 1102 | Supplying and fixing tool-less IO (Ethernet) flush/surface type in provided modular box as per specification no. WG-NAS/IO [1-12-2] |
| 1103 | Supplying and fixing tool-less shutter keystone jack (RJ-45) in provided patch panel complete as per specification no. WG-NAS/KJ [1-12-3] |
| 1104 | Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP [1-12-4] |
| 1105 | Supplying and fixing 9U wall mount rack (Dimension-DxWxH – 500x600x500 mm) as per specification No. WG-NAS/RAK [1-12-18] |
| 1106 | Supplying and fixing 36U floor mount server rack (Dimension-DxWxH – 800x600x1600 mm) as per specification No. WG-NAS/RAK [1-12-26] |
| 1107 | Supplying and erecting LED square / circular Max. 7W down lighter/ Panel Light having pressure die-cast aluminium housing polystyrene diffuser having system lumens output of Min. 770 Lumens min. efficacy of 110 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. max. ripple of 5% THD<10% p.f. >0.95 operating range of 120-270V surge protection of 2.5 kV Life class of 50 000 Hrs. at L70B50 including driver having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. [2-1-2] |
| 1108 | Supplying and erecting LED square / circular Max. 14 W down lighter/Panel Light having pressure die-cast aluminium housing polystyrene diffuser having system lumens output of Min. 1500 Lumens min. efficacy of 110 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. max. ripple of 5% THD<10% p.f. >0.95 operating range of 120-270V surge protection of 2.5 kV Life class of 50 000 Hrs. at L70B50 including driver having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. [2-1-4] |
| 1109 | Supplying and erecting LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing polystyrene diffuser having system lumens output of Min. 2000 Lumens min. efficacy of 110 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. max. ripple of 5% THD<10% p.f. >0.95 operating range of 120-270V surge protection of 2.5 kV Life class of 50 000 Hrs. at L70B50 including driver having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. [2-1-5] |
| 1110 | Supplying and erecting LED Panel Light(600mm X 600mm) Max. 30 W having CRCA powder coated housing polystyrene diffuser having system lumens output of Min. 3600 Lumens min. efficacy of 120 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. max. ripple of 5% THD<10% p.f. >0.95 operating range of 120-270V surge protection of 2.5 kV Life class of 50 000 Hrs. at L70B50 including driver having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. [2-1-7] |
| 1111 | Supplying and erecting LED Strip light 5m Length Max. 95 W IP20 class having minimum lumens output of 1600 Lumens/m min. efficacy of 90 lumen/W CRI>80 CCT upto 5000K Beam Angle of 110 deg. THD<10% p.f. >0.95 operating range of 230-270V Life class of 30 000 Hrs. at L70B50 including driver with 1 year warranty. [2-1-11] |
| 1112 | Supplying LED concealed type foot / step light with aluminium body for indoor/outdoor application suitable for 4W-6W LED including driver and erecting by making necessary arrangement / recess in wall to make it flush with surface with 1 year warranty. [2-1-12] |
| 1113 | Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens min. efficacy of 110 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. THD<10% p.f. >0.95 operating range of 140-260V in built surge protection of 2.5 kV Life class of 50 000 Hrs. at L70B50 including driver IP66 IK09 rated on provided PVC Block / wooden board with 3 years warranty. [2-1-15] |
| 1114 | Supplying and erecting anodized aluminium corridor / passage / mirror light LED fitting (2 feet) Max. 12W with high transitivity diffuser with min. system lumens output of 1200 lumens min. efficacy of 100 lumen/W CRI>80 CCT upto 6000K Beam Angle of 110 deg. Ripple<5% THD<10% p.f. >0.95 operating range of 200-270V surge protection of 2 kV Life class of 50 000 Hrs. at L70B50 including driver with end caps on provided PVC Block / wooden board with 3 years warranty. [2-1-16] |
| 1115 | Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens min. efficacy of 100 lumen/W CRI>80 CCT upto 6000K Beam Angle of 110 deg. Ripple<5% THD<10% p.f. >0.95 operating range of 200-270V surge protection of 2 kV Life class of 50 000 Hrs. at L70B50 including driver with end caps on provided PVC Block / wooden board with 3 years warranty. [2-1-18] |
| 1116 | Supplying and erecting inverter LED batten 20W tube light fitting with polycarbonate housing heat sink integrated HF electronic driver Min. 2600 mAh Lithium ion Battery with charging time of 8-10 Hours and backup time of Min. 3 hrs. with minimum 25% of initial Watts having luminous efficacy of 100 lumen/watt CRI>80 CCT of 6500K and THD<=20% having useful life of minimum 25000 hrs. with overheating protection with 2 years warranty. [2-1-22] |
| 1117 | Supplying and erecting Electronic type cordless call bell erected on T.W. board having portable bell push working on 9V D.C. battery and (effective range upto 45 meter) bell on 250 V A.C. supply. [2-3-15] |
| 1118 | Supplying and erecting regular/ standard model ceiling fan of 600mm. sweep complete erected in position as per specification no. FG-FN/CF [2-10-1] |
| 1119 | Supplying and erecting bracket fan 400 mm. sweep A. C. 230 volts 50 cycles 1350 RPM. Oscillating type plastic or metal blades chrome plated guard with speed regulator and moisture proof treatment to winding and with ‘E’ class insulation. [2-10-4] |
| 1120 | Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 300mm. 1400 RPM rust proof body & blades wire mesh duly erected complete. [2-10-13] |
| 1121 | Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm max. energy consumption of 28W having service ratio (CMM/W) of Min. 8 PF>0.9 THD<10% with IR remote control/compatible speed regulator Temperature Rise of Max. 40 deg. C having external mounted control PCB completely erected in position as per specification no. FG-FN/CF ( with note of 10 % reducction) [2-10-22] |
| 1122 | Supplying and erecting fan hook box of 10 mm M.S. round bar bounded to the R.C.C. bars upto 50 mm length each side and pierced through a 16 S.W.G. thick aluminium/M.S. Bowl 100 mm dia. or equivalent square size and having depth upto 75 mm complete erected with duly painted by one coat of red oxide paint and two coats of paint erected in position and without any leakage of slurry of cement concrete on either side of the box and positioned to the bottom level of the slab. [2-11-5] |
| 1123 | Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire. [2-11-6] |
| 1124 | Supplying, erecting, testing and commissioning of self contained water cooler 230/250V 50Hz nominal cooling capacity of 80 litres per hour and storage capacity 120 litres with partially stainless steel body as per specification no. AP-WCR/WC22 [3-3-9] |
| 1125 | Supplying and erecting ultra violet storage type water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps with output of purified water minimum 0.33 litre/min with activated carbon filter and softener operating on 230V single phase A.C. supply with UV fail & filter change indication system .(for TDS more than 200) [3-5-1] |
| 1126 | Supplying, installing, testing and commissioning of 3kVA capacity online pure sine wave with backup time of 30 Min. PWM & IGBT based UPS with 0.8 to unity output pf single phase input & 1 phase output complete with all protections as per specification no. AP-UPS [3-7-3] |
| 1127 | Supplying, installing, testing and commissioning of 6kVA capacity online pure sine wave with backup time of 30 Min. PWM & IGBT based UPS with 0.9 to unity output pf single phase input & 1 phase output complete with all protections as per specification no. AP-UPS [3-7-4] |
| 1128 | Supplying and erecting 12V/17Ah -18Ah SMF battery with battery terminal wire duly charged with 12 months warranty complete [3-8-8] |
| 1129 | Supplying and erecting 12V/26Ah SMF battery with battery terminal wire duly charged with 24 months warranty complete [3-8-9] |
| 1130 | Supplying, erecting and marking SPMCB 6A to 32A C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-2] |
| 1131 | Supplying, erecting and marking SPMCB 6A to 32A B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-3] |
| 1132 | Supplying, erecting and marking TPMCB 6A to 32A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-10] |
| 1133 | Supplying, erecting and marking TPMCB 40A to 63A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-11] |
| 1134 | Supplying, erecting and marking FPMCB 6A to 32A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-12] |
| 1135 | Supplying, erecting and marking FPMCB 40A to 63A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-13] |
| 1136 | Supplying and erecting triple pole and neutral distribution board (TPNDB) SPMCB of 4 ways/phase (12 poles) with door 1.2mm thickness surface/flush mounted IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB [5-4-1] |
| 1137 | Supplying and erecting triple pole and neutral distribution board (TPNDB) SPMCB of 8 ways / phase (24 poles) with door 1.2mm thickness surface/ flush mounted IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB [5-4-2] |
| 1138 | Supplying and erecting triple pole and neutral distribution board (TPNDB) SP/TP MCBs total 4 ways /12 Poles with door 1.2mm thickness surface/flush mounted IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB [5-4-4] |
| 1139 | Supplying and erecting triple pole and neutral distribution board (TPNDB) SP/TP MCBs total 8 ways /24 poles with door 1.2mm thickness surface/flush mounted IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB [5-4-5] |
| 1140 | Supplying and erecting single pole and neutral distribution board (SPNDB) with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs with door 1.2mm thickness surface / flush mounted IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB [5-4-9] |
| 1141 | Supplying and erecting triple pole and neutral distribution board (TPNDB) 3 pole/4 pole MCCB as incomer & outgoing SP MCB (36 poles) or TP MCB of 12 ways (36 poles) with door 1.2mm thickness surface/flush mounted on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1 [5-4-17] |
| 1142 | Providing and erecting 4 Pole MCCB 415 V 100A rated short-circuit breaking capacity 25 kA (Ics=100% of Icu) adjustable thermal (overload) setting and fixed magnetic setting with provided leads provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides insulation withstand capacity 800V no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB [5-5-1] |
| 1143 | Providing and erecting 4 Pole MCCB 415V 250A rated short-circuit breaking capacity 36 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides with insulation withstand capacity 800V no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB [5-5-3] |
| 1144 | Supplying, Erecting and Commissioning of 2 pole RCCB 16/25A electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB [5-6-1] |
| 1145 | Supplying, Erecting and Commissioning of 4 pole RCCB 16/25A electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB [5-6-4] |
| 1146 | Supplying, Erecting and Commissioning of 4 pole RCCB 40A electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB [5-6-5] |
| 1147 | Supplying, Erecting and Commissioning of 4 pole RCCB 63A electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB [5-6-6] |
| 1148 | Supplying, fixing, and commissioning 2 pole RCBO 6/10/16/20/25A with overcurrent rated short-circuit breaking capacity (10 kA) and earth leakage protection with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO [5-6-9] |
| 1149 | Supplying and erecting porcelain/epoxy bus bar support complete erected in provided M.S. box for 200/300A [5-10-27] |
| 1150 | Supplying and erecting porcelain/epoxy bus bar support complete erected in provided M.S. box for 400A [5-10-28] |
| 1151 | Supplying and erecting terminal spreaders suitable for 4 pole above 100A up to 250A MCCB (Set of 8) [5-11-7] |
| 1152 | Supplying and erecting terminal spreaders suitable for 4 pole above 250A up to 400A MCCB (Set of 8) [5-11-8] |
| 1153 | Supplying and erecting earth fault module for MCCB with adjustable earth fault sensitivity selection 10% to 50% of nominal current (In) and adjustable time delay 100/200 millisecond suitable for above 200A up to 400A MCCB with inbuilt CTs. [5-11-12] |
| 1154 | Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes panel boards etc. including cutting bending drilling welding riveting treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete. [6-1-1] |
| 1155 | Supplying and erecting iron work sheet metal work consisting of CRCA sheets various sections of iron plates chequered plates rods bars MS pipes etc. for panel board or any other purpose with bending cutting drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. [6-1-19] |
| 1156 | Supplying and erecting of any size electrolyte aluminium patti or bar in bus bar chamber / in panel or any other purpose 500 V with require capacity 99.9% aluminium purity with E91E Grade as per IS 5082 & Current Density 0.8 A per sq. mm. with fixing arrangement (like lug or bottle type lug) to both the end with high grade polyolefin insulation sleeve complete as per specification no. BCP-BB [6-2-11] |
| 1157 | Supplying and erecting Intelligent flush mounted panel meter three phase four wire (IPM) input voltage measurement range 50-550 V AC (P-P) 415V aux. supply 90-300 V AC/DC flush mounted (96 x 96 mm) meter constant Wh viewing in LCD multifunction meters in auto scroll mode with voltage current frequency power factor kW kVA kVAR kWh kVAh kVARh phase angle interrupts THD complete with RS 485 communication protocol class 1 accuracy and wiring connections and mounting hardware on provided panels complete with calibration certificate from manufacturer. [6-3-9] |
| 1158 | Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates. [6-5-2] |
| 1159 | Supplying and erecting LED type indicating pilot lamp with LED colours red / yellow / green 230 / 250V on provided box / panel with necessary material wiring & connections etc. [6-5-5] |
| 1160 | Supplying and erecting LED type indicating pilot lamp with LED colour blue 230 / 250 V on provided box / panel with necessary material wiring & connections etc. [6-5-6] |
| 1161 | Supplying and erecting 50 kVAr 440 V 3 phase 50 Hz. Contactor Logic & Intelligent Relay micro APFC passive filter panel consisting of suitable steps of APP/MPP type capacitor units with Detuned (harmonic filter) reactors of suitable rating APFC panel shall be compliance to IEC 61439 and power quality IEC 61921 standard as per specification no CP-ED/APFC [6-7-3] |
| 1162 | Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 35 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-16] |
| 1163 | Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 95 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-19] |
| 1164 | Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 120 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-20] |
| 1165 | Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 185 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-22] |
| 1166 | Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-29] |
| 1167 | Providing and erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 100 mm height comprising all required standard accessories. [7-11-1] |
| 1168 | Providing and erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 200 mm width & 100 mm height comprising all required standard accessories. [7-11-2] |
| 1169 | Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials testing & recording the results as per specification no. EA-EP [9-1-3] |
| 1170 | Providing earthing with copper earth plate size 60 x 60 x 0.315 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover with minimum 25 kg Carbon based environment friendly back fill Ground Enhancing compound complete with all materials testing & recording the results as per specification no ESE -LA [9-1-6] |
| 1171 | Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EA-EP. [9-2-2] |
| 1172 | Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. [9-2-3] |
| 1173 | Supplying and erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation complete. [9-3-1] |
| 1174 | Providing printed instruction chart for treating persons suffering from electric shock printed in English & Marathi and duly laminated complete. [10-6-22] |
| 1175 | Supplying standard first aid box with necessary antiseptic cream medicine for use on wounds due burn crepe bandage gauge bandage medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use scissors anti-septic solution etc. (All above contents shall be of standard makes) [10-6-24] |
| 1176 | Supplying and fixing PVC synthetic elastomer electrically insulating mat with class B insulation conforming to IS 15652 – 2006 having 2.5 mm thickness up to 11 kV [10-6-26] |
| 1177 | Name of work : Providing Lift System for the Proposed Krushi Bhavan Admin Building & Laboratory Building at Shahanpur Miya Dargah Dist. Chhatrapati Sambhaji Nager. (Subwork 4) |
| 1178 | Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No WG-MA/CC [1-1-9] |
| 1179 | Supplying and erecting green colour earthing with 1x 1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No WG-MA/BW [1-3-1] |
| 1180 | Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No WG-MA/BW [1-3-1] |
| 1181 | Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. [1-6-1] |
| 1182 | Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete. [1-6-2] |
| 1183 | Supplying and erecting modular type 3 pin 6A multi socket with safety shutter duly erected on provided plate and box with wiring connections complete. [1-6-10] |
| 1184 | Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter duly erected on provided plate and box with wiring connections complete. [1-6-11] |
| 1185 | Supplying and erecting modular type (two module) electronic step regulator for fan duly erected on provided plate and box with wiring connections complete. [1-6-23] |
| 1186 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 6 module duly erected. [1-6-30] |
| 1187 | Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires modular type switch earthing and required accessories as per specification No WG-PW/CW [1-7-5] |
| 1188 | Point wiring for ceiling fan concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires modular type switch earthing and required accessories as per specification No WG-PW/CW [1-7-6] |
| 1189 | Wiring for plug on board with Switch socket surface/concealed type copper wiring and earthing and with modular accessories as per specification No WG-PW/CW [1-7-26] |
| 1190 | Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens min. efficacy of 110 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. THD<10% p.f. >0.95 operating range of 140-260V in built surge protection of 2.5 kV Life class of 50 000 Hrs. at L70B50 including driver IP66 IK09 rated on provided PVC Block / wooden board with 3 years warranty. [2-1-15] |
| 1191 | Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens min. efficacy of 100 lumen/W CRI>80 CCT upto 6000K Beam Angle of 110 deg. Ripple<5% THD<10% p.f. >0.95 operating range of 200-270V surge protection of 2 kV Life class of 50 000 Hrs. at L70B50 including driver with end caps on provided PVC Block / wooden board with 3 years warranty. [2-1-18] |
| 1192 | Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 300mm. 1400 RPM rust proof body & blades wire mesh duly erected complete. [2-10-13] |
| 1193 | Supplying and erecting energy saving ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF [2-10-21] |
| 1194 | Supplying and erecting fan hook of 10 mm. M.S. round bar grouted in RCC slab with making the site as original. [2-11-4] |
| 1195 | Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire. [2-11-6] |
| 1196 | Supplying, erecting and marking SPMCB 6A to 32A C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-2] |
| 1197 | Supplying, erecting and marking SPMCB 6A to 32A B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-3] |
| 1198 | Supplying, erecting and marking TPMCB 40A to 63A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-11] |
| 1199 | Supplying and erecting triple pole and neutral distribution board (TPNDB) SP/TP MCBs total 4 ways /12 Poles with door 1.2mm thickness surface/flush mounted IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB [5-4-4] |
| 1200 | Supplying and erecting single pole and neutral distribution board (SPNDB) with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs with door 1.2mm thickness surface / flush mounted IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB [5-4-8] |
| 1201 | Supplying, fixing, and commissioning 2 pole RCBO 6/10/16/20/25A with overcurrent rated short-circuit breaking capacity (10 kA) and earth leakage protection with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO [5-6-9] |
| 1202 | Supplying, fixing, and commissioning 4 pole RCBO 32/40A with overcurrent rated short-circuit breaking capacity (10 kA) and earth leakage protection with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO [5-6-13] |
| 1203 | Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 2 core 2.5 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU [7-2-8] |
| 1204 | Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 2 core 4 sq mm copper conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU [7-2-9] |
| 1205 | Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 6 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU [7-2-32] |
| 1206 | Providing earthing with copper earth plate size 60 x 60 x 0.315 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover with minimum 25 kg Carbon based environment friendly back fill Ground Enhancing compound complete with all materials testing & recording the results as per specification no ESE -LA [9-1-6] |
| 1207 | Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EA-EP. [9-2-2] |
| 1208 | SITC of Duplex Lift control system for two nos. microprocessor/PLC based simplex lift controllers along with necessary software with programming and hardware e.g. logic board necessary communication/control/data cabling laying in rigid PVC conduits/trunking etc. complete. [17-1-21] |
| 1209 | SITC of Electric Traction Passenger Lift with · Rated capacity - 14 Passenger/952Kg · Floors - G+5 floor (6 Stops/6 Landings) · Travel - 3 to 4.2 mtrs (21mtr total ht)· Location of Lift Machine - MR · Rated speed - 1.0mps VS · Car/Landing door clear opening of 900 mm wide x 2000mm high · Clear Car size of 1600.mm wide x 1400.mm deep x 2250mm high · Lift shaft available having clear size of 2100 mm wide x 2200 mm deep 1500 mm Pit depth 4500 mm Overhead. Doors type - COPO/TOPO Doors with frame made from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory). · Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm thick with hairline finish with frame made from MS girders bracing of adequate size with minimum safety factor of 5 with Toe Guard Apron with necessary false ceiling with adequate LED lights blower/fan for ventilation & SS chequered plate flooring handrails mirror emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge. · COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI scrolling UP/DN LED indicator & with / without attendant key switch OWD with audio-visual alarm VAS in Marathi Hindi & English with intercom system with telephone instrument in Lift car LMR & FCC/ground floor. LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI Lift car arrival & next travel direction audio-visual indication at all landings Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent overvoltage over speed overheat for all devices including lift motor and travel direction protection protection for phase loss at input or output etc. various operation modes such as maintenance change direction by attendant full load bypass VIP call operation self levelling operation call cancel facility auto return to home landing fireman evacuation operation earthquake operation door open/close operation from COP etc. The system can record information for minimum 30 latest faults with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength copper wire for power & control circuit with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. ARD complete with necessary SMF VRLA batteries. Fireman controller having fireman switch at fire Landing CCTV surveillance system comprises of 2 nos minimum 2.0 MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup min. 90 days with min. 18” FHD TV monitor to be kept in FCC/LMR as directed by Engineer In Charge. Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory) with Traction pulley OSG electromagnetic brakes entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves suspension wire ropes/belts of adequate size & strength. Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners counter weight frame with necessary blocks buffers with necessary support arrangement MS pit ladder etc. erected with necessary steel work. Minor civil work such as alteration work if any necessary for erection of landing door frames and it's accessories e.g. sill header hole pass etc complete with plaster finish civil work for erection buffers erection of lift machinery adequate size core cuts if required & scaffolding for erecting guide rails providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT. General - Job includes entire procedure of obtaining all necessary erection permissions & License to Work the Lift from Electrical Inspector(Lifts) with submission to the Engineer In Charge. · The above rate includes Fully Comprehensive AMC for one year from the date of commissioning. (Rs.1531615/-) ADD ON A 3 For Lift having 900mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade solid (non-cladded) landing door [Two panel] this includes all necessary accessories like LOPs with UP/DN buttons-arrows-indicators extension of guide rails shaft wiring with trunking traveling cables main hoisting ropes/belts & OSG rope landing doors with all accessories etc. necessary for the normal safe functioning of lift installation complete.(RS. 141837*4floor = 567348/-) ADD ON C For additional 2MP Camera along with necessary accessories at Home Landing add as given. rs. 13460.00 Add ON C1 fully collective control system Rs.27340 So total for 1 lift cost (RS.1531615*1 +141837*4+ 27340*1 +13460) =2139763 [17-1-6] [30-1-491] |
| 1210 | Estimate No : 213007-5 of 2024-2025- Providing Fire Fighting System for the Proposed Krushi Bhavan Admin Building & Laboratory Building at Shahanpur Miya Dargah Dist. Chhatrapati Sambhaji Nager. (Subwork 5) |
| 1211 | Carrying out core cutting of size 3 to 5 dia x 15 length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. [3-11-77] |
| 1212 | Providing and fixing high-density polyethylene (HDPE) container one piece moulded triple layer water tank made out of high density polyethylene and built corrugated inclusive of delivery up to destination hoisting and fixing of accessories such as inlet outlet overflow pipe inclusive of all tanks capacity up to 20000 litres. [4-8-7] |
| 1213 | Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes panel boards etc. including cutting bending drilling welding riveting treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete. [6-1-1] |
| 1214 | Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3 core 4 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU [7-2-15] |
| 1215 | Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 95 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU [7-2-24] |
| 1216 | Providing and erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 300 mm width & 75 mm height complete with necessary coupler plates & hardware. [7-11-8] |
| 1217 | Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials testing & recording the results as per specification no. EA-EP [9-1-1] |
| 1218 | Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. [9-2-3] |
| 1219 | Supplying, installing, testing and commissioning of main fire pump (MFP / EP) suitable for water discharge of 2280 to 2850LPM at 80 to 60 m head driven by electric motor 415 volts 3 phase 50 Hz AC supply of 45kW or of suitable kW capacity for manual/automatic operation and consisting of following (a) Horizontal type single stage centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade) mechanical seal conforming to IS 1520.(b) Squirrel cage induction motor TEFC synchronous speed 3000 RPM suitable for operation with IP 55 protection for enclosure horizontal foot mounted type with Class-'F' insulation conforming to IS-325.(c) M.S. fabricated common base plate coupling coupling guard foundation bolts etc. as required.(d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-MFP/SSC/EP [13-1-4] |
| 1220 | Supplying, installing, testing and commissioning of jockey fire pump (JP) suitable for water discharge of 180 to 240 LPM at 70 to 50 m head driven by electric motor 415 volts 3 phase 50 Hz AC supply of 5.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following (a) Horizontal/vertical type multi stage centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade) mechanical seal conforming to IS 1520.(b) Squirrel cage induction motor TEFC synchronous speed 3000 RPM suitable for operation with IP 55 protection for enclosure horizontal foot mounted type with Class-'F' insulation conforming to IS-325.(c) M.S. fabricated common base plate coupling coupling guard foundation bolts etc. as required.(d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003)complete as per specification no. FF-MFP/JP [13-2-1] |
| 1221 | Supplying, installing, testing and commissioning of booster fire pump [BP] suitable for water discharge of 450 LPM at 35 m head driven by electric motor 415 volts 3 phase 50 Hz AC supply of 5.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following (a) Horizontal/vertical type single/multi stage centrifugal casing pump of cast iron body & bronze/CI impeller with stainless steel shaft (SS410 grade) mechanical seal conforming to IS 1520.(b) Squirrel cage induction motor TEFC synchronous speed 3000 RPM suitable for operation with IP 55 protection for enclosure horizontal foot mounted type with Class-'F' insulation conforming to IS-325.(c) M.S. fabricated common base plate coupling coupling guard foundation bolts etc. as required.(d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-MFP/BP [13-3-1] |
| 1222 | Supplying, installing, testing and commissioning of main fire pump (MFP/DP) suitable for water discharge of 2280 to 2850 LPM at 90 to 60 m head driven by 76 HP or suitable HP capacity diesel engine at required working speed suitable for manual/automatic operation and consisting of following (a) Horizontal type single stage centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade) mechanical seal conforming to IS 1520.(b) Water cooled with radiator diesel engine conforming to relevant IS standard complete with auto starting mechanism 12/24 volts DC electric starting equipment with battery of required AH capacity with necessary charger suitable to work on 230v 50Hz AC supply diesel tank of minimum 150ltr capacity with first filling of diesel up to 100% level with necessary piping with valves up to engine exhaust pipe extended up to 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding residential silencer instruments and protection as per standard specification stop solenoid for auto stop in the event of fault with audio indications etc. as required.(c) M.S. fabricated common base plate coupling coupling guard foundation bolts etc. as required.(d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning proper levelling complete pump set with engine assembly and accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-MFP/SSC/DP [13-4-2] |
| 1223 | Supplying and erecting G.I. pipe ‘C’ class ERW 25 mm dia with necessary fittings complete as per specification no. FF-PP [13-6-2] |
| 1224 | Supplying and erecting G.I. pipe ‘C’ class ERW 50 mm dia with necessary fittings complete as per specification no. FF-PP [13-6-3] |
| 1225 | Supplying and erecting G.I. pipe ‘C’ class ERW 65 mm dia with necessary fittings complete as per specification no. FF-PP [13-6-4] |
| 1226 | Supplying and erecting G.I. pipe ‘C’ class ERW 75/80 mm dia with necessary fittings complete as per specification no. FF-PP [13-6-5] |
| 1227 | Supplying and erecting G.I. pipe ‘C’ class ERW 100 mm dia with necessary fittings complete as per specification no. FF-PP [13-6-6] |
| 1228 | Supplying and erecting G.I. pipe ‘C’ class ERW 150 mm dia with necessary fittings complete as per specification no. FF-PP [13-6-7] |
| 1229 | Providing G.I. pipe ‘C’ class ERW 200 mm dia with necessary fittings complete as per specification no. FF-PP [13-6-8] |
| 1230 | Providing coating of bitumen paint & 4mm thick wrapping for underground 150 mm ring main of fire fighting system. [13-6-10] |
| 1231 | Supplying and erecting 200 mm dia Cast Iron end line strainer of Y-type flanged end pattern PN16 pressure rating screen of SS end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS [13-7-8] |
| 1232 | Supplying and erecting 150 mm dia. cast iron double flange sluice valve complete with PN16 pressure rating as per specification no. FF-VL/SV [13-7-15] |
| 1233 | Supplying and erecting 200 mm dia. cast iron double flange sluice valve complete with PN16 pressure rating as per specification no. FF-VL/SV [13-7-16] |
| 1234 | Supplying and erecting 65 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating as per specification no. FF-VL/BFV [13-7-18] |
| 1235 | Supplying and erecting 75/80 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating as per specification no. FF-VL/BFV [13-7-19] |
| 1236 | Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating as per specification no. FF-VL/BFV [13-7-20] |
| 1237 | Supplying and erecting 150 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating as per specification no. FF-VL/BFV [13-7-21] |
| 1238 | Supplying and erecting 100 mm dia cast iron double flange NRV complete with PN16 pressure rating as per specification no. FF-VL/NRV [13-7-24] |
| 1239 | Supplying and erecting 150 mm dia cast iron double flange NRV complete with PN16 pressure rating as per specification no. FF-VL/NRV [13-7-25] |
| 1240 | Supplying and erecting stainless steel double outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV [13-7-37] |
| 1241 | Supplying and installing wall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) along with necessary accessories complete as per specification no. FF-FFA/HV [13-8-2] |
| 1242 | Supplying and erecting 63mm dia reinforced rubber lined (R.R.L.) hose pipe 15m in length fitted with necessary accessories complete as per specification no. FF-FFA/RRL [13-8-4] |
| 1243 | Supplying and erecting stainless steel branch pipe 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specifications no. FF-FFA/NZ [13-8-8] |
| 1244 | Supplying and erecting 150 mm dia fire brigade header suitable for supplying water in fire tank complete as per specification no. FF-FA/FBC [13-8-10] |
| 1245 | Supplying and erecting 300 mm dia 1.5m in height air vessel / tank fabricated from min 5mm thick M.S. sheet complete as per specification no. FF-FFA/ACT [13-8-12] |
| 1246 | Supplying and erecting 20/25mm dia gun metal air release cock with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV [13-8-13] |
| 1247 | Supplying and erecting 100 mm dia. pressure gauge 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve erected with provided G.I. pipe elbow etc. complete as per specification no. FF-FFA/PG [13-8-14] |
| 1248 | Supplying and erecting 12/15 mm dia pressure switch with provided isolation valve G.I. nipple elbow etc complete as per specification no. FF-FFA/PS [13-8-15] |
| 1249 | Supplying and erecting brass orifice plate having 6 mm. thickness 140 mm outer dia with required diameter of inner hole at every single outlet hydrant valve as per specification no. FF-FFA/OP [13-8-16] |
| 1250 | Supplying and erecting M.S./CRCA cabinet for housing Fire Brigade / SIEMESE connections (size 1250 x 400 x 300 mm.) made from 16 SWG sheet and angle iron 25 mm. x 25 mm. x 4 mm. having front doors with viewing glass (8 x 6 ) and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5) [13-8-19] |
| 1251 | Supplying and erecting M.S./CRCA cabinet for housing Floor Hydrant valve hose pipe hose reel and branch pipe (size 1000 x 736 x 736 mm.) made from 16 SWG sheet and angle iron 25 x 25 x 4 mm. having front doors with viewing glass (8 x6 ) and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5) [13-8-20] |
| 1252 | Supplying, installing, testing and commissioning of remote response indicators suitable to operate on 5 - 28 V dc supply having FR Polymer ABS Housing complete as per specification no. FF-FAAS/RRI [13-9-9] |
| 1253 | Supplying, installing, testing and commissioning of FR XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU [13-9-10] |
| 1254 | Supplying, installing, testing and commissioning of micro processor based intelligent addressable main fire alarm panel central processing unit with the 2 loop capacity and capable of supporting upto 250 devices and detectors per loop with on-board LCD display with min 16 lines of text operating at 230 V 50 HZ - AC with inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 min in alarm condition suitable provision for network connectivity interfacing with third party equipment via a MODBUS/ OPC/ L-ON interface etc. conforming to IS 15908 2021 IS 2189 2008 EN 54 & VDS / FM/ UL 864 (10th edition) with 3 years replacement warranty FF-AFAS/CP. [13-10-2] |
| 1255 | Supplying, installing, testing and commissioning of repeater panel with suitable battery backup of a minimum of 24 hours in normal condition and 30 min in alarm condition 80 backlit alphanumeric LCD display with inbuilt buzzer to indicate fault/fire alarm manual control keys for silence/mute and to reset the FACP from the repeater station. Panel size shall not more than 175 x 275 x 65 mm conforming to EN 54 or UL approved with 3 years equipment replacement warranty FF-AFAS/RP [13-10-5] |
| 1256 | Supplying, installing, testing and commissioning of addressable optical smoke detector single/twin LED’s with 360 degree view suitable for low voltage 15 to 32 V DC two wires supply in-built locking mechanism to check the removal and pilferage of the detector in built isolation mode start up current 300µA and alarm condition current shall be maximum 6.5 mA operating temperature 0°C to 50°C humidity 0-95% RH IP 41 conforming to IS 2189 2008 11360_1985_Reff2020 EN 54 or UL Approved with 3 years equipment replacement warranty FF-AFAS/SD . [13-10-6] |
| 1257 | Supplying, installing, testing and commissioning of intelligent addressable thermal/heat detector with rate of rise cum fixed temperature thermistor complete with base as required suitable for temperature variations from -20°C to 38°C for fixed-heat and rate-of-rise type detectors and 0°C to 66°C for high heat type detectors in built isolation mode suitable for offices/ceiling cable trenches/less ventilation area's etc. with 3 years equipment replacement warranty IS 2175 - 1988 reaffirmed 2000 IS 15908 2021 standards FF-AFAS/SD. [13-10-7] |
| 1258 | Supplying, installing, testing and commissioning of addressable manual call points ( break glass type/pull station type) made of addressable break glass plastic square in shape surface/flush mounted with Break Glass massage embedded on the glass complete erected with mounting base and required accessories conforming to EN 54 or UL listed with 3 years equipment replacement warranty FF-AFAS/MCP. [13-10-9] |
| 1259 | Supplying, installing, testing and commissioning of addressable fire control/relay module complete as required with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) 1982 reed relays EN 54 or UL Listed FF-AFAS/CRM [13-10-10] |
| 1260 | Supplying, installing, testing and commissioning of addressable fire monitor module complete as required. EN 54 or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) 1982 Reed relays FF-AFAS/MM [13-10-11] |
| 1261 | Supplying, installing, testing and commissioning of addressable fire isolator module complete as required. EN 54 /FM or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) 1982 Reed relays FF-AFAS/ISM [13-10-12] |
| 1262 | Supplying, installing, testing and commissioning of addressable horn cum strobe sound/ hooter output frequency 500 to 1000 Hz with dB as per Chart given in IS 15908 2021 with flashing at 1 Hz over the strobe’s entire operating voltage range EN 54 conforming to IS 2189 2008 IS 15908 2021 standards with 3 years equipment replacement warranty FF-AFAS/SSH. [13-10-13] |
| 1263 | Supplying, erecting, testing and commissioning of 120 W amplifier suitable to operate on 230 Volts A.C. / 12 Volts D.C. supply complete as per specification no. FF-PA/AFR [13-11-1] |
| 1264 | Supplying, erecting, testing and commissioning of 15 to 30 Watts sound column or ceiling mounted complete as per specification no. FF-PA/SOC [13-11-2] |
| 1265 | Supplying, erecting, testing and commissioning of stand mounted/handheld type wired microphone having 2 mV/Pa sensitivity impedance level limit 300 ohms and 50 - 16000 Hz suitable to operate in -10 deg C to +55 deg C with min. 7 metre shielded cable and 3 Pin Professional XLR Connector stereo jack complete as per specification no. FF-PA/MIC [13-11-3] |
| 1266 | Supplying, erecting, testing and commissioning of rust free microphone floor stand of chrome plating/powder coating or S.S. material 500 mm to 1500 mm height and sturdy mechanism ensuring trouble free movement complete. [13-11-4] |
| 1267 | Supplying, erecting, testing and commissioning of 2 core shielded cable complete as per specification no. FF-PA/MCC [13-11-6] |
| 1268 | Supplying, erecting, testing and commissioning of 1.5 sq. mm speaker wire complete. [13-11-10] |
| 1269 | Supplying, erecting, testing and commissioning of quartzoid bulb sprinkler 15 mm (½ ) dia. NBCM Body chrome finished 68º C fixed temperature rating with deflector disc of conventional construction complete as per specification no. FF-SPR. [13-12-1] |
| 1270 | Supplying, erecting, testing and commissioning of vane type water flow detector 75/80 mm dia. with 1) Visual switch activation 2) Rugged switch assembly 3) Heavy duty aluminium pipe saddles 4)Durable metal enclosure 5) Steel U bolts for secure mounting 6) Two SPDT ( Single pole double track ) synchronised switches 7) serviceable without draining pipes. [13-12-2] |
| 1271 | Supplying and erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete. [13-15-1] |
| 1272 | Excavating hard Rock or bituminous road by chiselling for preparing pit for pole / stay/earth plate / for laying cable/ pipe & clearing the site by removing debris & making the site as required complete. [16-1-5] |
| 1273 | Excavating hard murum / stone metal road by chiselling for preparing pit for poles stay or earth plates or for laying cables pipes & clearing the site by removing debris & making the site as required complete. [16-1-6] |
| 1274 | Making cement concrete foundation in 1 2 4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included) (for pumps). [16-3-5] |
| 1275 | Supplying installing testing and commissioning of fire pump control panel (FCP) of cubical construction floor mounted type fabricated from minimum 2 mm thick CRCA sheet compartmentalised with hinged lockable doors with enclosure protection class IP54 duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) cable alley interconnection with suitable size solid copper busbar strip of adequate size for all power connections having switchgears and accessories mountings and internal wiring with adequate size copper conductor cable earth terminals numbering etc. complete in all respect suitable for satisfactory operation of main fire pump and jockey (pressurisation) pumps (1working+1standby) with necessary accessories wiring & cabling along with allied accessories with following incoming and outgoings suitable for automatic & manual operation on 415V 3 phase 50Hz ac supply as per specifications the capacity of electric motor driven pump are as follows a. Main fire pump(MFP) having capacity of 22kW 1no (1 working) b. Jockey pump(JP) capacity of suitable capacity 2 nos(1 working +1 standby alternate run per start in auto mode) comprises of the following features & switchgears 1. Main incomer FP SFU having rotary handle with HRC fuses of suitable rating. 2. Electrolytic grade copper strips for busbar of suitable sizes for main incomer and branches to motor SFU's starters & outgoing terminals with necessary accessories like stainless steel nut bolts with spring washers for connections mounted on required no of epoxy or porcelain support insulators of suitable ratings etc. 3. Individual pump TPN SFU having rotary handle with HRC fuses of suitable rating. 4. Digital voltmeter & ammeter & RYB indicating lamps & push buttons & SPP O/L & phase reversal protection with emergency stop switch. 5. TPN SPD 100kA Type 1 +2 tested. 6. Required pressure transducer with pressure indication on panel with cabling required for monitoring & automatic operation of fire pumps. 7. System controller to control operation of main electric fire pump jockey (pressurization) pumps in sequence with interlocking for operation of pumps as per specification with automatic/manual operation with selector switch & alternate run of standby Pumps consisting of relays timers. sensors annunciation window for fault indication complete as per specification. 8.Suitable capacity electric motor starters for all individual pumps with necessary push buttons & indications. 9. Siren of required capacity to be activated when main pump starts & allied accessories as per requirements of local CFO or as directed by engineer in charge. 10. Danger board as per IS. 11. Spare HRC fuses minimum 2nos of each individual rating with required bakelite fuse holder for main & jockey fire pumps MFP=(1working) JP = (1working+1standby alternate run per start in auto mode) complete panel as per specification no. FF-MFP/ECP ADD ON A For addition of capacity of main electric motor driven fire pump MFP (1 working) for hydrant system is more than 22kW add as follows in the basic cost of Item no 13-5-1 towards increased capacity switchgears and motor starters for main & jockey pumps along with necessary accessories for main & jockey fire pumps MFP=(1working) JP = (1working + 1standby alternate run per start in auto mode) For main electric motor driven fire hydrant system pump of 45kW capacity & relevant capacity jockey pump add Rs. 47687/- ADD ON B4 For addition of fire sprinkler system to basic fire hydrant system control panel(FCP) which includes one main electric motor driven fire pump MFP(1working) having __kW capacity & relevant capacity jockey pumps add as follows in the basic cost of Item no 13-5-1 towards increased capacity switchgears busbar and additional motor starters for main & jockey pumps along with necessary accessories with software & hardware for main & jockey fire pumps additional Sprinkler system MFP=(1working) 22kW JP =(1working+1standby alternate run per start in auto mode) relevant capacity For main electric motor driven fire sprinkler system pump of 45kW capacity (1Working) & relevant capacity jockey pumps (1working+1standby alternate run per start in auto mode add Rs. 200564/- ADD ON D For addition of standby main diesel engine driven fire pump (1 standby) add as follows in the basic cost of Item no 13-5-1 towards required 12/24 v battery charger and diesel engine starter along with necessary accessories indicators etc. with necessary interlocking and updation of control logic with interlocking for operation of pumps MFP for main (1working+1standby mode) & jockey fire pumps (1working+1standby alternate run per start in auto mode) add Rs....... The control for diesel engine comprises of automatic/manual selector switch & 3attempts starting device timers and relays as required push buttons start/stop in manual mode indicating lamp for high/ low Lub. oil pressure high water temp and engine on indication battery charger suitable for 12V/24 V DC with boost and trickle selector switch 0-30 V DC voltmeter and 0-20 A DC ammeter with all standard relays and accessories required for automatic operation of diesel engine with interlocking for operation of main fire pumps RS. 68381/- Add on E-For addition of booster pump for fire hydrant/sprinkler add as follows in the basic cost of item no 13-5-1 towards necessary accessories indicators etc. with necessary interlocking and updation of control logic add Rs.......for 5.5/ 7.5 kW centrifugal type booster pump 1no(1working) rs. 17994*2 + add Rs18893.7 SO TOTAL 182320+47686+200564+68381+ 35988 = RS. 534939 /-[13-5-1] [13-1-7] |
| 1276 | Supplying installing testing and commissioning of portable fire extinguishers of ABC dry powder stored pressure type fire extinguishers of 6 Kgs.capacity Complete with standard discharge valve with tube CI bracket for wall mounting etc. complete as per confirming to IS 15683 complete all the work up to the satisfaction of the Engineer in charge. [13-8-18] |
| 1277 | Supplying installation testing & commissioning of Sprinkler Flexible Pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer nipple 2 side brackets center bracket stockbar. The hose assembly includes 1200 mm long 28 mm diameter corrugated stainless steel flexible hose with a braided stainless steel exterior.complete all the work up to the satisfaction of the Engineer in charge. [13-8-20] |
| 1278 | Providing and fixing in position statutory Signage's made out of 3mm thick opaque PVC foam board machine cut non reflective auto glow (type & Make) with silicon adhesive for safe evacuation of occupants in case of emergency. Sign indicators should be provided at prominent places as per Fire Provisional NOC (As per - IS-9457 IS-12349 IS-12407). complete all the work up to the satisfaction of the Engineer in charge. [13-8-21] |
| 1279 | Estimate No : 213007-6 of 2024-2025- Providing Air Conditioning System for the Proposed Krushi Bhavan Admin Building & Laboratory Building at Shahanpur Miya Dargah Dist. Chhatrapati Sambhaji Nager. (Subwork 6) |
| 1280 | Supplying and erecting 25 mm dia. corrugated flexible polypropylene conduit [1-2-2] |
| 1281 | Supplying and erecting HMS PVC conduit FRLS grade 20 mm dia. with PVC accessories on wall / ceiling as per specification No WG-MA/CON [1-2-3] |
| 1282 | Supplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV [1-3-14] |
| 1283 | Supplying and erecting PVC insulated PVC round sheathed 2.5 sq.mm (50 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV [1-3-15] |
| 1284 | Supplying, installing, testing and commissioning of split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor room air conditioning unit 1.3TR to 1.6TR capacity having ISEER minimum 3.8 to maximum 4.39 suitable to operate on 250V 50 Hz A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser minimum 2.5PM filter self diagnosis feature stabilizer free operation & temperature display on indoor unit noise level maximum 50dBA at position as per specification no. APAC/ WAC [3-2-10] |
| 1285 | Supplying, installing, testing and commissioning of cassette type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor room Air conditioning unit 1.8TR to 2.1TR capacity having ISEER minimum 5.00 suitable to operate on 250V 50 Hz A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32/R410A having copper condenser dust filter self diagnosis feature stabilizer free operation noise level maximum 50dBA at position as per specification no. APAC/ WAC [3-2-18] |
| 1286 | Providing vaccumising the airconditioner system to 200 micron and charging with refrigerant R32 for AC unit. [3-10-24] |
| 1287 | Supplying, erecting, testing and commissioning of 12HP VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant for minimum cooling capacity as delivering 100% capacity at 47° C non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00 modular type vertical hot air discharge suitable for longer piping range upto 1000m operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area rain protection cover built in oil separator accumulator and oil receiver copper tube aluminium fin air cooled condenser condenser fan with motor suitable for 415V±10% 50 Hz 3 phase power supply (all suitable for high ambient conditions) internal copper refrigerant piping internal wiring and refrigerant etc. all housed in powder coated weather proof cabinet complete. [3-11-4] |
| 1288 | Supplying, erecting, testing and commissioning of 20HP VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant for minimum cooling capacity as delivering 100% capacity at 47° C non stop cooling even at 56°C and coefficient of performance (COP) 3.00 to 4.00 modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area rain protection cover built in oil separator accumulator and oil receiver copper tube aluminium fin air cooled condenser condenser fan with motor suitable for 415V±10% 50 Hz 3 phase power supply (all suitable for high ambient conditions) internal copper refrigerant piping internal wiring and refrigerant etc. all housed in powder coated weather proof cabinet complete. [3-11-8] |
| 1289 | Supplying, erecting, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact / standard size) of nominal cooling capacity 3.0TR (1100 cfm) to 3.2TR (1165 cfm) having EER as per BEE standards and specifications suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements fan refrigerant liquid and refrigerant piping cordless remote control and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase 230V 50Hz AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation. [3-11-22] |
| 1290 | Carrying out core cutting of size 3 to 5 dia x 15 length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. [3-11-77] |
| 1291 | Supplying, erecting, testing and commissioning of wireless remote control having colour LCD panel real time clock temperature limitation (16 to 30° C functions like filter clean reminder timer suitable to communicate with wired controller complete. [3-11-78] |
| 1292 | Providing adhesive thermal insulation for supply return air duct with 19mm nitrile rubber insulation having R-value as per the prevailing provisions in ECBC-2017. [3-11-83] |
| 1293 | Supplying and installing of high pressure grade required size copper connection Y or T- Joints/refnet complete erected on wall/ceiling with supports/raceways Nitrile rubber insulation painting etc. with brazing and testing for leakages confirming the normal operation of the VRV/VRF air conditioning system. [3-11-86] |
| 1294 | Supplying, laying / fixing, testing and commissioning of of appropriate nominal refrigerant copper pipe of 28.6mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports hangers clamps vibration isolators and fittings such as bends tees valves gauges strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages fungal growth flame spread water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete. [3-11-91] |
| 1295 | Supplying, laying / fixing, testing and commissioning of of appropriate nominal refrigerant copper pipe of 22.2mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports hangers clamps vibration isolators and fittings such as bends tees valves gauges strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages fungal growth flame spread water permeance and ultraviolet radiation with OEM standards of VRV/VRF air conditioning system complete. [3-11-92] |
| 1296 | Supplying, laying / fixing, testing and commissioning of of appropriate nominal refrigerant copper pipe of 19.1mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports hangers clamps vibration isolators and fittings such as bends tees valves gauges strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages fungal growth flame spread water permeance and ultraviolet radiations with OEM standards of VRV/VRF air conditioning system complete. [3-11-93] |
| 1297 | Supplying and erecting 25/32 mm (ID/OD) Chlorinated polyvinyl chloride pipe (CPVC) thickness 3.2 mm conforming to IS 15778 (CTS Series) with necessary CPVC fittings and solvent cement for Solar Water Heater System as per specification No. ESD-HWP/CPVC [4-2-19] |
| 1298 | Supplying, laying / fixing, testing and commissioning of of appropriate nominal refrigerant copper pipe of 15.9 mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports hangers clamps vibration isolators and fittings such as bends tees valves gauges strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages fungal growth flame spread water permeance and ultraviolet radiations with OEM standards of VRV/VRF air conditioning system complete. [3-11-94] |
| 1299 | Supplying, laying / fixing, testing and commissioning of of appropriate nominal refrigerant copper pipe of 9.5 mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports hangers clamps vibration isolators and fittings such as bends tees valves gauges strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages fungal growth flame spread water permeance and ultraviolet radiations with OEM standards of VRV/VRF air conditioning system complete. [3-11-96] |
| 1300 | Supplying and erecting 32/40 mm (ID/OD) Chlorinated polyvinyl chloride pipe (CPVC) thickness 3.8 mm conforming to IS 15778 (CTS Series) with necessary CPVC fittings and solvent cement for Solar Water Heater System as per specification No. ESD-HWP/CPVC [4-2-20] |
| 1301 | Supplying and erecting 25/32 mm (ID/OD) Chlorinated polyvinyl chloride pipe (CPVC) thickness 3.2 mm conforming to IS 15778 (CTS Series) with necessary CPVC fittings and solvent cement for Solar Water Heater System as per specification No. ESD-HWP/CPVC [4-2-19] |
| 1302 | Supplying and erecting 32/40 mm (ID/OD) Chlorinated polyvinyl chloride pipe (CPVC) thickness 3.8 mm conforming to IS 15778 (CTS Series) with necessary CPVC fittings and solvent cement for Solar Water Heater System as per specification No. ESD-HWP/CPVC [4-2-20] |
| 1303 | Supplying and erecting 40/50 mm (ID/OD) Chlorinated polyvinyl chloride pipe (CPVC) thickness 3.8 mm conforming to IS 15778 (CTS Series) with necessary CPVC fittings and solvent cement for Solar Water Heater System as per specification No. ESD-HWP/CPVC [4-2-21] |
| 1304 | Supplying, erecting and marking triple pole isolators only switch version of miniature circuit breaker of 100A with required wiring connections and lugs etc. in provided distribution board. [5-3-17] |
| 1305 | Supplying and erecting triple pole and neutral distribution board (TPNDB) 3 pole/ 4 pole MCCB as incomer & outgoing SP MCB (12 poles) or TP MCB of 4 ways (12 poles) with door 1.2mm thickness surface/flush mounted on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1 [5-4-15] |
| 1306 | Providing and erecting 4 Pole MCCB 415 V 100A rated short-circuit breaking capacity 25 kA (Ics=100% of Icu) adjustable thermal (overload) setting and fixed magnetic setting with provided leads provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides insulation withstand capacity 800V no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB [5-5-1] |
| 1307 | Supplying, Erecting and Commissioning of 2 pole RCCB 16/25A electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB [5-6-1] |
| 1308 | Supplying and erecting iron work sheet metal work consisting of CRCA sheets various sections of iron plates chequered plates rods bars MS pipes etc. for panel board or any other purpose with bending cutting drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. [6-1-19] |
| 1309 | Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-29] |
| 1310 | Providing and erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 100 mm height comprising all required standard accessories. [7-11-1] |
| 1311 | Estimate No : 213007-7 of 2024-2025-Providing Water Pump System for the Proposed Krushi Bhavan Admin Building & Laboratory Building at Shahanpur Miya Dargah Dist. Chhatrapati Sambhaji Nager. (Subwork 7) |
| 1312 | Supplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV [1-3-14] |
| 1313 | Supplying, erecting and marking TPMCB 6A to 32A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-10] |
| 1314 | Supplying, erecting and marking FPMCB 6A to 32A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-12] |
| 1315 | Supplying, fixing, and commissioning MCB type change over switch 4 pole 25A with 3 positions (I-O-II) with centre off position as per specification no. SW-SWR / MCBCOS [5-3-24] |
| 1316 | Supplying and erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame. [5-4-13] |
| 1317 | Supplying and erecting plywood 12 mm thick fixed to wall or on provided panel board with necessary materials such as screws wall fasteners supports nuts bolts etc. complete. [6-1-12] |
| 1318 | Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-28] |
| 1319 | Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials testing & recording the results as per specification no. EA-EP [9-1-3] |
| 1320 | Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. [9-2-3] |
| 1321 | Supplying and erecting minimum Three & above star rated submersible pump set of 2.25 KW/3 HP with 415 V 50 c/s AC supply suitable for 150 mm dia. borewell suitable for 120 to 390 LPM discharge at 55 to 11 m head & discharge & delivery Pipe of Size-50mm diameter with a necessary H type clamps as per specification No. WP-SMP [12-2-1] |
| 1322 | Supplying and erecting minimum Three & above star rated submersible pump set suitable for erection on open well of 5.625 KW/7.5 HP with 415 V 50 c/s. A.C. supply having delivery head from 36 to 14m and discharge from 225 to 1680 litres. per minute& pipe of Suction 75 mm/Delivery 65 mm diameter erected with necessary H type clamps as per specification No. WP-OSP [12-3-3] |
| 1323 | Supplying and erecting flat flexible 3 core 4 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. [12-4-9] |
| 1324 | Supplying and erecting Water level controller 230/415 V A.C. Four way under ground & Over head tank operation only. [12-4-15] |
| 1325 | Supplying and erecting automatic control panel for 3 Phase 415 volt A.C Submersible/centrifugal pump set up to 7.5 HP consisting of DOL starter having relay range 9-14 AMP S.P.P. Combined ammeter/ voltmeter phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing phase reversal phase imbalance etc . [12-4-17] |
| 1326 | Supplying and erecting ISI mark GI pipe 50 mm dia.‘B’ class at position with accessories complete as per specification no. CW-PLB/GP. [16-5-6] |
| 1327 | Supplying and erecting ISI mark GI pipe 65 mm. dia. ‘B’ class at position with accessories complete as per specification no. CW-PLB/GP. [16-5-7] |
| 1328 | Supplying and erecting ISI mark GI pipe 100 mm dia ‘C” class position with accessories complete. Specification no. CW-PLB/GP. [16-5-15] |
| 1329 | Supplying and erecting high density polythene pipe ISI mark 50 mm. dia. suitable for pressure of 6 kg. / cm2 connected to jet/submersible pump with required material complete. [16-5-18] |
| 1330 | Supplying and erecting non return valve 50 mm dia in position made of gun metal complete. [16-6-21] |
| 1331 | Supplying and erecting non return valve 65 mm dia in position made of gun metal complete. [16-6-22] |
| 1332 | Estimate No : 213007-8 of 2024-2025- Providing CCTV System for the Proposed Krushi Bhavan Admin Building & Laboratory Building at Shahanpur Miya Dargah Dist. Chhatrapati Sambhaji Nager. (Subwork 8) |
| 1333 | Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with PVC accessories on wall /ceiling as per specification No WG-MA/CON. [1-2-4] |
| 1334 | Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No WG-MA/BW [1-3-1] |
| 1335 | Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No WG-MA/BW [1-3-1] |
| 1336 | Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. [1-6-1] |
| 1337 | Supplying and erecting modular type 3 pin 6A multi socket with safety shutter duly erected on provided plate and box with wiring connections complete. [1-6-10] |
| 1338 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 12 module duly erected. [1-6-32] |
| 1339 | Supplying and erecting 3m HDMI cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete. [1-8-21] |
| 1340 | Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC [1-10-1] |
| 1341 | Supplying, fixing, and configuring 24 ports + (4 SFP+) POE switch 370W 6KV surge protection on ethernet port and console port for management on provided rack as per specification No. WG-NWC/ENS [1-11-9] |
| 1342 | Supplying, installing & testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC. [1-12-1] |
| 1343 | Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 500x600x367 mm) as per specification No. WG-NAS/RAK [1-12-17] |
| 1344 | Supplying, installing, testing and commissioning of 2kVA capacity online pure sine wave with backup time of ....... hrs. PWM & IGBT based UPS with 0.8 to unity output pf single phase input & 1 phase output complete with all protections as per specification no. AP-UPS [3-7-2] |
| 1345 | Supplying and erecting 12 V/65Ah SMF battery with battery terminal wire duly charged complete with 24 months warranty complete [3-8-11] |
| 1346 | Supplying & erecting of High definition 4/5 Megapixel IP IR Dome Camera with following features Image Sensor minimum 1/2.8 Progressive Scan CMOS Video Resolution minimum 2592 x 1520 Video Compression H.264 H.265 or higher at least Three individually configurable stream Frame rate minimum 25 fps at all resolutions WDR minimum 120 dB Wide Dynamic Range ONVIF profile conformant minimum IR distance 50m Lens Type 2.8/4/6 mm Lens fixed focal Field of View 2.8 mm horizontal FOV 107° vertical FOV 57° diagonal FOV 129° 4 mm horizontal FOV 86° vertical FOV 47° diagonal FOV 102° 6 mm horizontal FOV 55° vertical FOV 29° diagonal FOV 65° Lux sensitivity - minimum 0.2 Lux at color minimum 0.05 Lux at Black & White 0.0 Lux (IR) Night Vision Distance minimum IR - 50m. Camera minimum Adjustment Angles - Pan 350° Tilt 72° Rotate 350°. Power Supply Support 12VDC & PoE IP67 IK10 - Vandal Resistant. Built in micro SD/SDHC/SDXC card slot of minimum 128 GB Built in microphone. minimum Input/Output - Audio in × 1 Audio Out × 1 Alarm in × 1 Alarm Out × 1. Image Settings Rotate mode saturation brightness contrast sharpness gain white balance. Image Enhancements Day/Night-Auto (ICR)/Color/Black & White 3D Digital Noise Reduction Automatic White Balance Automatic Gain Control Backlight Compensation Highlight Compensation. [35-1-28] |
| 1347 | Supplying & erecting of High definition 4/5 Megapixel IP IR Bullet Camera with following features Image Sensor minimum 1/2.8 Progressive Scan CMOS Video Resolution minimum 2592 x 1520 Video Compression H.264 H.265 or higher at least Three individually configurable stream Frame rate minimum 25 fps at all resolutions WDR minimum 120 dB Wide Dynamic Range ONVIF profile conformant minimum IR distance 50m Lens Type 2.8/4/6 mm Lens fixed focal Field of View 2.8 mm horizontal FOV 107° vertical FOV 57° diagonal FOV 129° 4 mm horizontal FOV 86° vertical FOV 47° diagonal FOV 102° 6 mm horizontal FOV 55° vertical FOV 29° diagonal FOV 65°Lux sensitivity - minimum 0.2 Lux at color minimum 0.05 Lux at Black & White 0.0 Lux (IR) Night Vision Distance minimum IR - 50m. Camera minimum Adjustment Angles - Pan 350° Tilt 72° Rotate 350°. Power Supply Support 12VDC & PoE IP67 IK10 - Vandal Resistant. Built in micro SD/SDHC/SDXC card slot of minimum 128 GB Built in microphone. minimum Input/Output - Audio in × 1 Audio Out × 1 Alarm in × 1 Alarm Out × 1. Image Settings Rotate mode saturation brightness contrast sharpness gain white balance. Image Enhancements Day/Night-Auto (ICR)/Color/Black & White 3D Digital Noise Reduction Automatic White Balance Automatic Gain Control Backlight Compensation Highlight Compensation. [35-1-29] |
| 1348 | Supplying installing testing & commissioning of 32/40 Ch. Network Video Recorder (NVR) suitable connect Min. 32 IP Cameras up to 5 Megapixel Resolution with HDMI/VGA outputs provided HDMI output of 4K resolution or VGA output with output up to 1920 × 1080. Support H.265 or higher H.264 MJPEG Incoming Bandwidth 250Mbps with minimum 4 SATA Hard Disks ANR Technology 4 SATA interfaces for 4 HDDs and capacity of each HDD up to 8TB minimum 02 USB port Alarm I/O 16/4 RJ-45 10/100/ 1000 Mbps self-adaptive Ethernet interface ONVIF conformance Multiple network monitoring Web viewer . support protocol TCP/IP DHCP DNS DDNS NTP SADP SMTP NFS iSCSI UPnP™ HTTPS. RoHS UL CE FCC certified. duly erected in provided U Rack with wiring connections tagging and programming etc. complete as per specification no. CCTV-NVR [35-2-20] |
| 1349 | Supplying & erecting 8 TB internal Surveillance HDD suitable for SATA Port of NVR interface transfer rate 6 GB/S maximum sustained transfer rate 210 MB/Sec to 213 MB/S. Drive bay supported 08+ Cameras supported up to 64 Cache (MB) 256 Load/Unload Cycle -3000000 Work Load Rating per Year 180TB MTBF 1000000 Hrs. HTTPS. RoHS UL CE certified duly erected in position in provided NVR as per specification no. CCTV-HDD [35-3-11] |
| 1350 | Supplying & erecting 55 professional LED display with 1920 *1080 ( Full HD) Display suitable for 32/64 channel NVR and following features Brightness minimum 500 Cd/m2 Contrast Ratio minimum 1000 1 Viewing angle 178/178 deg. Response time maximum 8 ms Inputs HDMI VGA BNC USB Audio In Built-in speakers maximum 10 W Suitable to operate on 100-240 V 50 Hz AC supply and 24/7 Duty Cycle duly erected on wall or table top with standard accessories like wall mount stand and wiring connections etc. complete as per specifications no. CCTV-MON [35-5-17] |
| 1351 | Name of work : Providing Street Light System for the Proposed Krushi Bhavan Admin Building & Laboratory Building at Shahanpur Miya Dargah Dist. Chhatrapati Sambhaji Nager. (Subwork 9) |
| 1352 | Supplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV [1-3-14] |
| 1353 | Supplying and erecting integrated LED street light fitting 60W IP65 & IK08 class having single piece pressure die-cast aluminium housing having system lumens output of Min. 6600 Lumens min. efficacy of 110 lumen/W CRI>70 CCT upto 6500K THD<10% p.f. >0.95 operating range of 140-270V inbuilt surge protection of 10 kV Life class of 50 000 Hrs. at L70B50 including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2. [2-4-5] |
| 1354 | Supplying and erecting three phase 415V street light control panel up to the max load of 6kW TPN MCB 40A powder coated CRCA 14 SWG sheet outdoor type having IP54 IK10 protection suitable rating contactor 24 hrs. astronomical time switch with minimum 5 years battery back up auto/manual selector switch ON/OFF push buttons indicator lamps control wiring metering device etc. for automatic operation with overcurrent short circuit earth fault protection on provided iron frame / CC foundation. [5-2-5] |
| 1355 | Supplying, erecting and marking SPMCB 0.5A to 5A C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-1] |
| 1356 | Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 6 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-27] |
| 1357 | Supplying and laying (including excavation) of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface to required depth complete. [7-6-9] |
| 1358 | Providing and erecting 7 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL [8-2-13] |
| 1359 | Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT [8-2-21] |
| 1360 | Providing and erecting galvanised 1000mm double arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT [8-2-22] |
| 1361 | Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials testing & recording the results as per specification no. EA-EP [9-1-1] |
| 1362 | Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP [9-1-4] |
| 1363 | Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. [9-2-3] |
| 1364 | Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel concrete excavation and fixing provided nut bolts with the help of template duly plastered as per design complete (for 6m to 8m high octagonal /conical GI pole). [16-3-9] Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail