| 1 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. |
| 2 | All kind of soil |
| 3 | Ordinary Rock |
| 4 | Earth work in excavation by mechanical means (hydraulic excavator)/manual means in foundation trenches of drains (not exceeding 1.5m in width or 10sqm on plan including dressing of sides and ramming of bottoms lift upto 1.5m including getting out the excavated soil and disposal of surplus excavated soil as directed with in lead of 50mtr |
| 5 | All kinds of soil |
| 6 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 7 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing1:5:10 (1 cement : 5 coarse sand) : 10 graded stone aggregate 40 mm nominal size). |
| 8 | Providing and laying, mechanically mixed and vibrated cement concrete 1:5:10 (one cement:Five sand Ten graded crushed stone aggregate 40 mm (forty millimeter) nominal size) including curing as required at site complete excluding the cost of form work but including all leads and lifts of materials in foundation and plinth and as per direction of Engineer -in -charge. |
| 9 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand) : 6 gradedstone aggregate 20 mm nominal size) |
| 10 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 11 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand): 3 graded stone aggregate 20 mm nominal size) |
| 12 | All work up to plinth |
| 13 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : |
| 14 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering |
| 15 | Providing from work with steel plates 3.15 mm (three decimal fifteen millimeter ) thick welded with angle iron in frame 30X30X5 mm (thirty into thirty into five millimeters )so as to give a fair finish including centering , shuttering ,strutting and propping etc. with wooden battens and ballies for all heights of propping and centering below supporting floor to ceiling & removal of same for in-situ reinforced concrete and plain concrete work in . |
| 16 | Foundation ,footing basis of columns etc. And mass concrete as per direction of the Engineer-in-charge including carriage of material with in all leads , lifts in all floor levels and other incidentals. |
| 17 | Flat surfaces, such as soffits of the suspended floors roofs , landing and the like floors etc. up to any thickness , all as per direction of the Engineer-in Charge including s carriage of material with in all leads ,lifts in all floor levels and other incidentals |
| 18 | Beams cantilever girders and lintels side and soffits of beams ,beams haunchings, cantilevers ,bressumers and lintels not exceeding 1 mtr in depth in all heights from floor as per direction of the Engineer-in Charge including carriage of material with in all leads ,lifts in all floor levels and other incidentals. |
| 19 | Columns, pillars ,posts and struts square, rectangular or polygonal in plan as per direction of the Engineer-in Charge Inculdings carriage of material with in all leads ,lifts in all floor levels and other incidentals |
| 20 | Stair case with sloping or stepped soffits excluding landing as per direction of the Engineer-in Charge Inculdings carriage of material with in all leads ,lifts in all floor levels and other incidentals |
| 21 | Form work in edges of slab and breaks in floor and walls under 20cm wide as per direction of the Engineer-in Charge Inculdings carriage of material with in all leads ,lifts in all floor levels and other incidentals |
| 22 | Centering and shuttering including strutting, propping etc. and removal of form work for Retaining walls, return walls, walls (anythickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc |
| 23 | Providing tor steel reinforcement for reinforced concrete work including bending and placing in position and cost of binding wire complete for all floors including carriage of material with in all leads and lifts and other incidentals . |
| 24 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 25 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand) |
| 26 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 27 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in Flooring in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. Supplying, filling, spreading & leveling |
| 28 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shade Area of slab over 0.50 sqm |
| 29 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.Granite work |
| 30 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 31 | Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth.Granite stone of approved shade |
| 32 | Providing wood work in framesofdoors,windows,clerestory windows and other frames,wroughtframed and fixed in positionwith holdfast lugs or with dash fasteners o frequired dia & length (holdfast lugs or dash fasteners shall be paid for separately). Sal wood |
| 33 | Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured). |
| 34 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 35 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). |
| 36 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. |
| 37 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : |
| 38 | 300x16 mm |
| 39 | 250x16 mm |
| 40 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 41 | 200x10 mm |
| 42 | Providing and fixing 50 cm long aluminium kicking plate of size 100x3.15 mm, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete |
| 43 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 44 | 125 mm |
| 45 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Twin rubber stopper |
| 46 | Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) |
| 47 | Casement cum fixed panel window having both end single casement panel, middle fixed panels and at top completely fixed ventilator with S.S friction hinges (350 x 19 x 1.9) made of (big series) frame 67 x 60 mm , sash 67 x 80 mm & mullion 67 x 80 mm all having wall thickness of 2.3 ± 0.2 mm and single glazing bead/double glazing bead of appropriate dimension. (Area of window above 3.00 sqm upto 5.00 sqm). |
| 48 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. |
| 49 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 50 | Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) |
| 51 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete size of tile 600x600mm |
| 52 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete Size of tile 600x600mm |
| 53 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 54 | 110 mm diameter |
| 55 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. |
| 56 | 110mm bend |
| 57 | 110mm shoe |
| 58 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 59 | 110mm |
| 60 | 6mm(six millimeter)thick cement plaster to ceiling in cement mortar 1:3 (one cement :three sand as per direction of engineer-in- charge including carriage of material with In all leads , lifts in all floors and other incidentals completes |
| 61 | 15mm (fifteen millimeter) thick cement plaster in single coat on rough / fair side of brick /concrete/stone wall for interior plastering for all floors including arises internal rounded angles chafers and / or rounded angles chamfers and/ or rounded angles not exceeding 80mm (eighty millimeters )In girth and finished even and smooth in cement mortar 1:6 (one cement :six sand )as per direction of engineer in charge including carriage of material within all leads lifts in all floors and other incidental |
| 62 | 20mm (twenty millimeter) thick cement plaster in single coat on rough / fair side of brick /concrete/stone wall for interior plastering for all floors including arises internal rounded angles chafers and / or rounded angles chamfers and/ or rounded angles not exceeding 80mm (eighty millimeters )In girth and finished even and smooth in cement mortar 1:4(one cement :four sand )as per direction of engineer in charge including carriage of material within all leads lifts in all floors and other incidental |
| 63 | 18 mm thick plain cement mortar band in cement mortar 1:4 (1 cement : 4 fine sand):: Raised Band |
| 64 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 65 | Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats |
| 66 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture |
| 67 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate |
| 68 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture |
| 69 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid as per direction of the Engineer-in Charge Inculdings carriage of material with in all leads ,lifts in all floor levels and other incidentals complete in all respect . |
| 70 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings andbrackets, cutting and making good the walls wherever require: White Vitreous China Flat back wash basin size 450x 300 mm with single 15mm C.P.brass pillar tap as per direction of the Engineer-in Charge Inculdings carriage of material with in all leads ,lifts in all floor levels and other incidentals complete in all respect . |
| 71 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:893115 mm nominal bore as per direction of the Engineer-in Charge Inculdings carriage of material with in all leads ,lifts in all floor levels and other incidentals complete in all respect . |
| 72 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. |
| 73 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore 15 mm nominal bore as per direction of the Engineer-in Charge Inculdings carriage of material with in all leads ,lifts in all floor levels and other incidentals complete in all respect . |
| 74 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end25 mm nominal bor as per direction of the Engineer-in Charge Inculdings carriage of material with in all leads ,lifts in all floor levels and other incidentals complete in all respect . |
| 75 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :510x1040 mm bowl depth 250 as per direction of the Engineer-in Charge Inculdings carriage of material with in all leads ,lifts in all floor levels and other incidentals complete in all respect . |
| 76 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. as per direction of the Engineer-in Charge Inculdings carriage of material with in all leads ,lifts in all floor levels and other incidentals complete in all respect . |
| 77 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.as per direction of the Engineer-in Charge Inculdings carriage of material with in all leads ,lifts in all floor levels and other incidentals complete in all respect . |
| 78 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : as per direction of the Engineer-in Charge Inculdings carriage of material with in all leads ,lifts in all floor levels and other incidentals complete in all respect . |
| 79 | Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall : ( including all Fittings ) |
| 80 | 15 mm (fifteen millimeters) nominal bore |
| 81 | 20 mm (twenty millimeters) nominal bore |
| 82 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. as per direction of the Engineer-in Charge Inculdings carriage of material with in all leads ,lifts in all floor levels and other incidentals complete in all respect . ( Including all fiittings ) |
| 83 | 15 mm (fifteen millimeters) nominal bore |
| 84 | 20 mm (twenty millimeters) nominal bore |
| 85 | Providing and fixing PVC water storage tank of Sintex or equvalent make of ISI :12701 Marked ,G.I. inlet and outlet connection , 15mm nominal bore ball valve and mosquito proof PVC cover with locking arrangement including hoisting up to all heights above ground Level (1000 litres net capacity tank)including carriage of material upto all leads and lifts in all floor as per direction of the Engineer-in Charge Inculdings carriage of material with in all leads ,lifts in all floor levels and other incidentals complete in all respect . |
| 86 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. as per direction of the Engineer-in Charge Inculdings carriage of material with in all leads ,lifts in all floor levels and other incidentals complete in all respect . |
| 87 | 75 mm nominal size (seventy five millimeters) size |
| 88 | 110 mm nominal size (one hundred ten millimeters) size |
| 89 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. as per direction of the Engineer-in Charge Inculdings carriage of material with in all leads ,lifts in all floor levels and other incidentals complete in all respect . |
| 90 | Coupler 75 mm |
| 91 | Coupler 110 mm |
| 92 | Bend 87.5° 75 mm |
| 93 | Bend 87.5° 110 mm |
| 94 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 Fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design Inside dimensions 455x610 mm and 45 cm deep for single pipe line : 19.30.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 as per direction of the Engineer-in Charge Inculdings carriage of material with in all leads ,lifts in all floor levels and other incidentals complete in all respect . |
| 95 | Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality Rectangular shape 600x450 mm internal dimensions as per direction of the Engineer-in Charge Inculdings carriage of material with in all leads ,lifts in all floor levels and other incidentals complete in all respect . |
| 96 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. JINDAL or TATA Make Only |
| 97 | Providing and fixing ridges or hips 60 cm overall with 0.60 mm thick prepainted steel sheets in roofing with hot dipped metalic zinc coated sheets with top coat of regular modified polyster organic coating of 20 microns over 5 microns primer coating + back coat of po;yster of 5 microns over 5 microns primer coating i/c fixing with prepainted iron Jor L hooks ,bolts & nuts 6 mm dia prepainted G.I. limpet andbitumen washers complete with all accessories as required as per the direction of Engineer - in - Charges. |
| 98 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes |
| 99 | Providing and fixing 15 cm wide, 45 cm overall semicircular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete. Please Enable Macros to View BoQ information |