| 1 | Centering and shuttering including strutting, propping etc. and removal of form for : as per direction of the Engineer-in Charge Inculdings carriage of material with in all leads ,lifts in all floor levels and other incidentals complete in all respect . |
| 2 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 3 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 4 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand): 3 graded stone aggregate 20 mm nominal size) but including all leads and lifts of materials in foundation and plinth and as per direction of Engineer -in -charge |
| 5 | In walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up tofloor five level |
| 6 | In beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, |
| 7 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete . Thermo-Mechanically Treated bars of grade Fe-500D or more. including all leads and lifts of materials in foundation and plinth and as per direction of Engineer -in -charge. |
| 8 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) including all leads and lifts of materials in foundation and plinth and as per direction of Engineer -in -charge. |
| 9 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand) including all leads and lifts of materials in foundation and plinth and as per direction of Engineer -in -charge. |
| 10 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). Sal wood including all leads and lifts of materials in foundation and plinth and as per direction of Engineer -in -charge. |
| 11 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. including all leads and lifts of materials in foundation and plinth and as per direction of Engineer -in -charge. |
| 12 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws Kiln seasoned and chemically treated hollock wood 35 mm thick including all leads and lifts of materials in foundation and plinth and as per direction of Engineer -in -charge. |
| 13 | Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws ncluding all leads and lifts of materials in foundation and plinth and as per direction of Engineer -in -charge. |
| 14 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete Fixed to openings /wooden frames with rawl plugs screws etc as per direction of the Engineer-in Charge Inculdings carriage of material with in all leads ,lifts in all floor levels and other incidentals complete in all respect . |
| 15 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). ncluding all leads and lifts of materials in foundation and plinth and as per direction of Engineer -in -charge. |
| 16 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : as per direction of the Engineer-in Charge Inculdings carriage of material with in all leads ,lifts in all floor levels and other incidentals complete in all respect . |
| 17 | 250x16mm |
| 18 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : as per direction of the Engineer-in Charge Inculdings carriage of material with in all leads ,lifts in all floor levels and other incidentals complete in all respect . |
| 19 | 200x10mm |
| 20 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete as per direction of the Engineer-in Charge Inculdings carriage of material with in all leads ,lifts in all floor levels and other incidentals complete in all respect . |
| 21 | 125mm |
| 22 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper as per direction of the Engineer-in Charge Inculdings carriage of material with in all leads ,lifts in all floor levels and other incidentals complete in all respect . |
| 23 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete Tile Size 600x600 mm as per direction of the Engineer-in Charge Inculdings carriage of material with in all leads ,lifts in all floor levels and other incidentals complete in all respect . |
| 24 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointingin white cement mixed with pigment of matching shade complete. |
| 25 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 26 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture as per direction of the Engineer-in Charge Inculdings carriage of material with in all leads ,lifts in all floor levels and other incidentals complete in all respect . |
| 27 | Smooth finishing of the exposed surface of R.C.C. work with 6 mm thick cement mortar 1:3 (1 Cement : 3 fine sand). |
| 28 | 15 mm cement plaster on rough side of single or half brick wall of mix 1:4 (1 cement: 4 coarse sand) as per direction of the Engineer-in Charge Inculdings carriage of material with in all leads ,lifts in all floor levels and other incidentals complete in all respect . as per direction of the Engineer-in Charge Inculdings carriage of material with in all leads ,lifts in all floor levels and other incidentals complete in all respect . |
| 29 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. as per direction of the Engineer-in Charge Inculdings carriage of material with in all leads ,lifts in all floor levels and other incidentals complete in all respect . |
| 30 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade Two or more coats on new work as per direction of the Engineer-in Charge Inculdings carriage of material with in all leads ,lifts in all floor levels and other incidentals complete in all respect . |
| 31 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives.New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and includingpriming coat of exterior primer applied @ 0.90 litre/10 sqm. as per direction of the Engineer-in Charge Inculdings carriage of material with in all leads ,lifts in all floor levels and other incidentals complete in all respect . |
| 32 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid as per direction of the Engineer-in Charge Inculdings carriage of material with in all leads ,lifts in all floor levels and other incidentals complete in all respect . |
| 33 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings andbrackets, cutting and making good the walls wherever require: White Vitreous China Flat back wash basin size 450x 300 mm with single 15mm C.P.brass pillar tap as per direction of the Engineer-in Charge Inculdings carriage of material with in all leads ,lifts in all floor levels and other incidentals complete in all respect . |
| 34 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:893115 mm nominal bore as per direction of the Engineer-in Charge Inculdings carriage of material with in all leads ,lifts in all floor levels and other incidentals complete in all respect . |
| 35 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. |
| 36 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore 15 mm nominal bore as per direction of the Engineer-in Charge Inculdings carriage of material with in all leads ,lifts in all floor levels and other incidentals complete in all respect . |
| 37 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end25 mm nominal bor as per direction of the Engineer-in Charge Inculdings carriage of material with in all leads ,lifts in all floor levels and other incidentals complete in all respect . |
| 38 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. as per direction of the Engineer-in Charge Inculdings carriage of material with in all leads ,lifts in all floor levels and other incidentals complete in all respect . |
| 39 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.as per direction of the Engineer-in Charge Inculdings carriage of material with in all leads ,lifts in all floor levels and other incidentals complete in all respect . |
| 40 | Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall : |
| 41 | 15 mm (fifteen millimeters) nominal bore |
| 42 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. as per direction of the Engineer-in Charge Inculdings carriage of material with in all leads ,lifts in all floor levels and other incidentals complete in all respect . |
| 43 | 15 mm (fifteen millimeters) nominal bore |
| 44 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : |
| 45 | 15 mm (fifteen millimeters) nominal bore |
| 46 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. as per direction of the Engineer-in Charge Inculdings carriage of material with in all leads ,lifts in all floor levels and other incidentals complete in all respect . |
| 47 | 75 mm nominal size (seventy five millimeters) size |
| 48 | 110 mm nominal size (one hundred ten millimeters) size |
| 49 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. as per direction of the Engineer-in Charge Inculdings carriage of material with in all leads ,lifts in all floor levels and other incidentals complete in all respect . |
| 50 | Coupler 75 mm |
| 51 | Coupler 110 mm |
| 52 | Bend 87.5° 75 mm |
| 53 | Bend 87.5° 110 mm |
| 54 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required as per direction of the Engineer-in Charge Inculdings carriage of material with in all leads ,lifts in all floor levels and other incidentals complete in all respect . |
| 55 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. JINDAL or TATA Make Only |
| 56 | Providing and fixing ridges or hips 60 cm overall with 0.60 mm thick prepainted steel sheets in roofing with hot dipped metalic zinc coated sheets with top coat of regular modified polyster organic coating of 20 microns over 5 microns primer coating + back coat of po;yster of 5 microns over 5 microns primer coating i/c fixing with prepainted iron Jor L hooks ,bolts & nuts 6 mm dia prepainted G.I. limpet andbitumen washers complete with all accessories as required as per the direction of Engineer - in - Charges. |
| 57 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes |
| 58 | Providing and fixing 15 cm wide, 45 cm overall semicircular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete. |
| 59 | 12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to IS: 2095 part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with center borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.79, with 50 mm resin bonded glass wool backing. |
| 60 | Providing and fixing flat pressed 3 layer particle board medium density exterior grade (Grade I) or graded wood particle board IS : 3087 marked, to frame, backing or studding with screws etc. complete (Frames, backing or studding to be paid separately): |
| 61 | Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position with necessary stainless steel screws etc Kiln seasoned and chemically treatedhollock wood Please Enable Macros to View BoQ information |