| 1 | Civil Work: as mentioned below: - The rate quoted shall be inclusive of all manpower, material, consumables, T&P, transportation, lift, scaffolding, loading/ unloading cartrage etc. complete in all respect. as per Technical Specification & Scope of Work as directed by the Engineer in charge. |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. |
| 3 | Cement mortar 1:1 (1 cement : 1 fine sand). |
| 4 | Centering and shuttering including strutting, propping etc. and removal of form work for : Foundations, footings, bases for columns. |
| 5 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level: 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 6 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 7 | Providing & fixing at all heights, levels and locations colour finish Aluminium alloy roofing sheets of alloy IS designation 31500, temper Hx8 conforming to IS 737 and dimensions as per IS code 2676 with characteristics of good formability and corrosion resistance. The profile sheets shall be fixed to truss members in slope or required pitch or curvature with Hex cap headed self drilling/tapping Stainless steel screws M6, 50 mm long with 3 mm EPDM seal washer etc. all inclusive of labour, scaffolding, T&P and sundries etc. complete as per directions of the Engineer-In-Charge. (Cost of truss/frame work shall be paid separately). 0.91mm Aluminium colour coated profile with center to center pitch of 175 mm, depth of 46mm, top crest width of 41mm, bottom valley width of 80mm, overall profile width of 1144mm, cover width 1050mm. |
| 8 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 9 | Supply & Application of Epoxy Coating on various metallic structures including all cost of manpower, material, consumables T&P, and Transportation etc. complete in all respect as Per Technical Specifications & Scope of work annexed herewith as directed by the Engineer in charge. |
| 10 | Electrification Works as mentioned below: - The rate quoted shall be inclusive of all manpower, material, consumables, T&P, transportation, lift, scaffolding, loading/ unloading cartrage etc. complete in all respect. as per Technical Specification & Scope of Work as directed by the Engineer in charge |
| 11 | Supply and installation of UL listed, CPRI tested copper bounded steel electrode of minimum 17.2 mm dia. (as per IEC 62561-2) With a minimum coating thickness of 250 microns and length of 3 meters, filled with anti corrosive conductive compounds with the permanent sealings at both the ends as per point mentioned (a), (b), (c), (d), (e) below:- (a) filled with anticorrosive conductive compounds with the permanent sealings at both the ends, CPRI/ERDA tested with RMS capacity of minimum 35-40KA for with standing 1 second (b) To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000 mm of resistance lowering earth enhancement material shall be used as a back fill compound. The compound shall be tested form NABL accredited lab for low resistivity (less than 0.12 Ohm - meter) & high conductivity in nature with carbon as a major content. ( c ) Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size10 kV external. cable shall be rigidly supported and made out by flexible copper wires (upto 125 amp) and by solid bus bar (>125 amp). required. |
| 12 | Providing & Fixing of ISO Certified company made lightning conductor finial for electrical Works as per IS 2309-1989 made out of 25 mm dia.,300 mm long copper solid rod having single prong at top with 85 mm dia, 3mm thick copper base plate including holes etc. complete as required. |
| 13 | Supply & Laying following size 25mm x 5mm copper earth strip in horizontal or vertical round/surface/recess including riveting, soldering, saddles, Jointing shall be done by over lapping and with 2 set of Brass (for Cu strip) /GI (for GI Strip) nut bolt & spring washer spaced at 50 cm making connection etc. as required. |
| 14 | Providing & Fixing of (High Power LED Flood Light 300W) IK07 IP-66 protected high power LED flood light system with Pressure die cast aluminium housing LM6/ADC12 material, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, 240 volt, 50Hz, of high power LED lamps. Integrated driver must be potted & has a unique BIS R number shall be high efficiency having efficiency more than 85 % and in compliance to BIS certifiedand T.C.certificate. The System level Luminaire efficiency >=120 lm/ watt with High Power LEDs is to be used. LED driver Input Voltage AC 120 V to 270 V AC with High voltage Cut off @ >= 300 V AC and Auto resetting Safety. Input Frequency 50Hz ± 3%, PowerFactor > 0.95, driver Efficiency >85%,THD(I) < 10 %, driver current < 1000 mA. |
| 15 | Providing & Fixing of IP-65 Protected LED aviation obstruction light Min. 15 Watts luminaire comprising of die cast aluminium alloy housing with Polycarbonate enclosure having more than 200 Nos Low Power LED's having minimum power consumption 15 watts complete in all respect. |
| 16 | Providing of LT Power Cables- Copper Conductor Core-4 Cable (Size 6 sq. mm. |
| 17 | Supply & laying of DWC HDPE Pipe ISI marked alongwith all accessories like socket, bend, coupler etc. confirming to IS:14930 Part-2 complete with fitting & cutting, jointing etc. direct in ground 75 cm mtr. Depth below the ground level including excavation & refilling the trench but excluding sand cushioning and protective covering etc. complete as required. 63 mm Dia (Outer Dia-63 & Inner dia-51 mm Nominal). |
| 18 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size (Upto 35 sq. mm) direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 19 | Supplying and making one end termination with heavy duty brass compression gland (as per IS12943-1990) SIBG type, heavy duty aluminium lugs (as per IS 8309 -1993 & IS: 8337-1976 ) duly crimped with crimping tool, PVC tape for electrical Works etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required of size. |
| 20 | Providing & Laying of Supplying and fixing of following sizes (25 mm) of medium class Steel conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 21 | Providing & Fixing of MCB 2 pole 6Amp, Breaking Capacity: 10. |
| 22 | Wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required for Group-C. |
| 23 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 24 | Supplying and fixing size/modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 8 Module (125mm X 125mm). |
| 25 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 26 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. Slot, up to 128 GB, IR Range 30 meters, IP 66 & POE, (2 Megapixel IR Night Vision Bullet Camera) Please Enable Macros to View BoQ information |