| 1 | PART-A: Civil Work |
| 2 | Earth work in excavation of foundation trenches in all kinds of soil including moorum, stoney earth and earth mixed with boulders except sheet rock and boulders requred depth and deposting the excavted materials away from the work site with all leads and lifts including shoring shuttering & dewatering (if required ) with cost of labour hire & running charges of water pumps sundries & T & P required for the work complete as directed by the Engineer in charge. |
| 3 | Providing anti termite treatment to bottom and sides of column, pits, walls,trenches foundation and plinth filling below floor sides corners and juction of walls ans floors, jambs and seals of door and windows using chemicals as per approved specifications and instruction of EIC including cost, conveyance and taxes of all materials, labour etc. complete (as per IS specification) (plinth area Ground Floor shall be considered for payments).as directed by the Engineer in charge. |
| 4 | Filling foundation trenches and plinth with excavated earth including watering ramming and compacting in layers not exceeding 150mm thick including labour sundries T&P etc complete and as per direction of engineer-in-charge. |
| 5 | Supplying and filling in foundation trenches and plinth, ditches with sand well watered and rammed in layers not exceeding 23cm in depth with all lead and lift including cost, conveyance, loading, unloading, royalities and taxes of all materials cost of all labor sundries T&P required of the work etc complete in all respect as directed by the engineer in charge ( measurement will be taken on finished compacted section only.) |
| 6 | Cement concrete (1:3:6) with 4cm size crusher broken granite metal per one cum. including cost of materials, transportation, and placing as per direction of EIC. |
| 7 | Cement concrete (1:2:4)with 12mm size Crusher broken granite chips per 1cum including cost of materials, transportation, and placing as per direction of EIC. |
| 8 | Providing lifting, hosting and laying reinforced cement concrete M-20 Grade in column base, column footings and raft foundation as per approved designs and drawings having a minimum compressive strenth (in work test ) 200 kg/ sq. cm in 15 cm cubes at 28 days after mixing and test conducted in accordance with IS 456 and IS 516 using 12 mm to 20 mm size black hard crusher broken granite stone hips and screened and washed sharp sand for mortar of approved quality from approved quarry washed and cleaned (20 mm size chips not to exceed 25%) to be mixed in concrete mixture with cement including hoisting lowering, laying and compacting concrete by using vibrators, watering and curring for 28 days. centering and shuttering then after dismantaling and removing debrises from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalities and taxes of all materials, labour with T & P required for the work etc. complete in all respect but excluding cost and conveyance of M.S rods of tor steel and binding wires and labour charges for straightening, cutting, beding etc of MS rods or steel lying the grills and placing in proper position as directed by the Engineer in charge. |
| 9 | Provisding lifting, hosting and laying reinforced cement concrete M-20 Grade in column upto plinth & super structure as per approved designs and drawings having a minimum compressive strenth (in work test ) 200 kg/ sq. cm in 15 cm cubes at 28 days after mixing and test conducted in accordance with IS 456 and IS 516 using 12 mm to 20 mm size black hard crusher broken granite stone hips and screened and washed sharp sand for mortar of approved quality from approved quarry washed and cleaned (20 mm size chips not to exceed 25%) to be mixed in concrete mixture with cement including hoisting lowering, laying and compacting concrete by using vibrators, watering and curring for 28 days. centering and shuttering then after dismantaling and removing debrises from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalities and taxes of all materials, labour with T & P required for the work etc. complete in all respect but excluding cost and conveyance of M.S rods of tor steel and binding wires and labour charges for straightening, cutting, beding etc of MS rods or steel lying the grills and placing in proper position. |
| 10 | Providing lifting, hosting and laying reinforced cement concrete M-20 Grade in all kinds of Beams as per approved designs and drawings having a minimum compressive strenth (in work test ) 200 kg/ sq. cm in 15 cm cubes at 28 days after mixing and test conducted in accordance with IS 456 and IS 516 using 12 mm to 20 mm size black hard crusher broken granite stone hips and screened and washed sharp sand for mortar of approved quality from approved quarry washed and cleaned (20 mm size chips not to exceed 25%) to be mixed in concrete mixture with cement including hoisting lowering, laying and compacting concrete by using vibrators, watering and curring for 28 days. centering and shuttering then after dismantaling and removing debrises from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalities and taxes of all materials, labour with T & P required for the work etc. complete in all respect but excluding cost and conveyance of M.S rods of tor steel and binding wires and labour charges for straightening, cutting, beding etc of MS rods or steel lying the grills and placing in proper position as directed by the Engineer in charge. |
| 11 | Providing lifting, hosting and laying reinforced cement concrete M-20 Grade in all kinds of roof slab as per approved designs and drawings having a minimum compressive strenth (in work test ) 200 kg/ sq. cm in 15 cm cubes at 28 days after mixing and test conducted in accordance with IS 456 and IS 516 using 12 mm to 20 mm size black hard crusher broken granite stone hips and screened and washed sharp sand for mortar of approved quality from approved quarry washed and cleaned (20 mm size chips not to exceed 25%) to be mixed in concrete mixture with cement including hoisting lowering, laying and compacting concrete by using vibrators, watering and curring for 28 days. centering and shuttering then after dismantaling and removing debrises from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalities and taxes of all materials, labour with T & P required for the work etc. complete in all respect but excluding cost and conveyance of M.S rods of tor steel and binding wires and labour charges for straightening, cutting, beding etc of MS rods or steel lying the grills and placing in proper position.as directed by the Engineer in charge. |
| 12 | Providing lifting, hosting and laying reinforced cement concrete M-20 Grade in Lintels as per approved designs and drawings having a minimum compressive strenth (in work test ) 200 kg/ sq. cm in 15 cm cubes at 28 days after mixing and test conducted in accordance with IS 456 and IS 516 using 12 mm to 20 mm size black hard crusher broken granite stone hips and screened and washed sharp sand for mortar of approved quality from approved quarry washed and cleaned (20 mm size chips not to exceed 25%) to be mixed in concrete mixture with cement including hoisting lowering, laying and compacting concrete by using vibrators, watering and curring for 28 days. centering and shuttering then after dismantaling and removing debrises from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalities and taxes of all materials, labour with T & P required for the work etc. complete in all respect but excluding cost and conveyance of M.S rods of tor steel and binding wires and labour charges for straightening, cutting, beding etc of MS rods or steel lying the grills and placing in proper position.as directed by the Engineer in charge. |
| 13 | Providing lifting, hosting and laying reinforced cement concrete M-20 Grade in Staircase as per approved designs and drawings having a minimum compressive strenth (in work test ) 200 kg/ sq. cm in 15 cm cubes at 28 days after mixing and test conducted in accordance with IS 456 and IS 516 using 12 mm to 20 mm size black hard crusher broken granite stone hips and screened and washed sharp sand for mortar of approved quality from approved quarry washed and cleaned (20 mm size chips not to exceed 25%) to be mixed in concrete mixture with cement including hoisting lowering, laying and compacting concrete by using vibrators, watering and curring for 28 days. centering and shuttering then after dismantaling and removing debrises from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalities and taxes of all materials, labour with T & P required for the work etc. complete in all respect but excluding cost and conveyance of M.S rods of tor steel and binding wires and labour charges for straightening, cutting, beding etc of MS rods or steel lying the grills and placing in proper position.directed by the Engineer in charge. |
| 14 | Cutting, straightening coiled or bentup M.S plain HYSD/TMT reinforcement bars welding or jointing if nessary bending, binding, tying the grills as required for R.C.C works, providinfg fan hooks where necessary and hoisting, lowering and placing in proper position according to approved designs and drawings including cost, conveyance, loading, unloading & taxes of MS plain /HYSD/TMT reinfocement bars and binding wires of 18 to 20 gauge requires for the work and cost of all labour, sundries, T&P and scaffolding complete in all respect as directed by the EIC (payment will be made according to the actual weight of MS plain/HYSD/TMT reinfocrement bars consumed in the work only) |
| 15 | Rigid and smooth centering and shuttering for RCC works including false work. Etc., complete including hoisting and laying materials, transportation, and placing as per direction of EIC. |
| 16 | Footing (Building+Verandah) |
| 17 | Column (Building+ Verandah) |
| 18 | All kind of Beams |
| 19 | Lintel (Building) |
| 20 | All kind of Slabs |
| 21 | Paver Block Side Wall |
| 22 | C.B Brick (23x11x8cm) size having crushing strength not less than 35kg/ cm2 with cement mortar (1:6) in foundation and plinth per cum including hoisting and laying materials, transportation, and placing as per direction of EIC. |
| 23 | Providing 12mm thick cement plaster (inside) in all floors at all height with cement mortar of mix (1:6) with cement and screened & washed sharp sand for mortar and finished to smooth to the rough surface of the brick masnory wall after racking out joints (alongwith providing grooves wherever necessary) including watering and curing rouding of corner etc. complete with cost, conveyance, loading, unloading, royalties and taxes of all materials, cost all labour, I & P, sundries and scaffolding required for the work etc as directed br the EIC. |
| 24 | Providing 16 mm thick cement plaster (outside) in all floors at all height with cement mortar of mix (1:6) with cement and screened & washed sharp sand for mortar and finished to smooth to the rough surface of the brick masnory wall after racking out joints (alongwith providing grooves wherever necessary) including watering and curing rouding of corner etc. complete with cost, conveyance, loading, unloading, royalties and taxes of all materials, cost all labour, I & P, sundries and scaffolding required for the work etc as directed br the EIC. |
| 25 | 4 cm thick grading concrete (1:2:4) on roof slab with 12mm & down grade size black hard granite chips for old work including cost of materials, transportation, and placing as per direction of EIC. |
| 26 | Providing 10 mm thick Vertrified Tile flooring using Vertified Tile of size (600x600 mm) of approved quality & colour in floors, treads on steps and landing on 20 mm thick bed of cement mortar mix of (1:4) confirming to I.S-1443/1972 with screened and washed sharp sand for mortar and cement grouted with gray cement slurry laid in proper slope joining the kota stone with neat white cement slurry mixed with with required quantity of pigment of approved marks to match the shades of the kota stojne to kota stone colour it required, watering and curing for 21 days. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost all labour, T & P, sundries required for the work including rubbing mechanically and wax polishing etc. in all floors at all height complete in all respect as directed by the EIC. |
| 27 | Providing fitting & fixing of wall tiles in dados skirting and rises of steps on 25mm thick bed of cement mortar 1:3 joined with neat cement slurry mixed with pigment to match the shades of the tiles of approved makes confirming to I.S. 13753 coloured/printed series (Homogeneous) including cost, conveyance etc complete as per direction of EIC. |
| 28 | Providing fitting & fixing of Anti-skid ceramic tiles in rises of steps on 25mm thick bed of cement mortar 1:3 joined with neat cement slurry mixed with pigment to match the shades of the tiles of approved makes confirming to I.S. 13753 coloured/printed series (Homogeneous) including cost, conveyance etc complete as per direction of EIC. |
| 29 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of required size comprising of virgin polymer of K value 58- 60 (Suspension Grade),calcium carbonate and natural fibers (wood powder/rice hus /wheat husk) and non toxic additives (maximum toxicity index of 12 for lOO gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum Compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being Termite/borer proof, water/moisture proof And Fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted w,,th hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk 5.5 screws, all as per direction of Engineer-In- Charge.(Note: stainless steel butt hinges and necessary 5.5 screws shall be paid separately) |
| 30 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/ Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed S5 screws having minimum frame density of 750kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge),minimum compressive strength of 58 N/mm2,modulus of elasticity 900N/mm2 and resistance to spread of flame of Class A category with property of being Termite/borer proof, water/moisture proof and Fire retardant and fixed in position with M.5 hold fast/lugs /SS dash fasteners of required dia and length complete as per direction of Engineer-In-Charge.(M.5 hold fast/lugs or SS dash fasteners shall be paid for separately) |
| 31 | Supplying, fitting, fixing of pristine white UPVC framed two track UPVC sliding window with approved make of 6mm thick glass of approved quality and complete with frame, shutters and all fitting and fixtures as per direction of Engineer-incharge. |
| 32 | Supply and fixing of cement concrete ventilators of 1'x1.5' Size including cost of all materials labours,royality,taxes and duties etc.as per direction EIC. |
| 33 | Finishing wall surface of walls with Acrylic wall putty (Water based ) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials taxes, labour T&P etc complete. As per direction of EIC. |
| 34 | Priming 1 coat with any appproved Primer (Asian/Berger) on plastered surface including cost of materials, labour, transportation etc. & complete as per direction of EIC. |
| 35 | Painting 2(two) coats with Weather coat paint of jonson &Nicolsion /Asian/Berger of approved quality and colour, using the required quality of paint as specified by the manufacturer to give an even shade over a coat of wall primer over the external plastered surface including watering surface before applying and curinf for the required period as directed by EIC for all floor including cost of all materials with taxes and transportation all labour scaffolding, sundries, T & p etc complete. |
| 36 | Painting 2(two) coats to the inner plastered surface using approved quality of Plastic Emulsion Paint of any approved shade over a coat of wall putty and primer making smooth to the surface and receive distemper in all floors at all heights. scaffolding and preparing the surface smooth including cost conveyance, loading, unloading and taxes of all materials cost of all labour sundries and T&P etc. Required for the work complete in all respect as directed by EIC. |
| 37 | Supplying, fitting & fixing MS grill of approved design made out of MS flat, square bars etc with necessary welded clamps fixed in position to proper plimb including a coat of oprimer of approved quality metalic primer, making holes in walls and grouting clamps with RCC (1:2:4) with 12 mm size black hard crusher broken granitye chips, making good to damages of walls including cost conveyance, loading, unloading and taxes of all materials cost of all labour sundries and T&P etc. Required for the work complete in all respect as directed by EIC. (weight to be measured properly prior to fixing the grills and payment to be made accordingly. |
| 38 | Priming one coat with any approved primer (Asian/Berger) (Iron Work) including cost, conveyance all materilas, labour and T & P etc complete as per direction of EIC. |
| 39 | Painting two coats with approved paint on wood work & Iron work (Asian/Berger) (New) including cost, conveyance all materilas, labour and T & P etc complete as per direction of EIC. |
| 40 | Providing, fitting & fixing the stainless steel hand rail of 304 grade using 50mm dia 2mm thick circular pipe fixing in proper position on RCC structures by making holes at required places complete including cost conveyance, loading, unloading and taxes of all materials cost of all labour sundries and T&P, scaffolding etc. Required for the work complete in all respect as directed by EIC. |
| 41 | Providing and laying 80mm thick factory made cement concrete interlocking paver block of M-40 grade made by block making machine with strong vibratory compaction, of approved size,design & shape,laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand,filling the joints with line sand etc all complete as per the direction of EIC. |
| 42 | PART-B: Electrical Work |
| 43 | Recessed Wiring to light point / Fan Point/ exhaust fan point/call Bell Point with 1.5 sq.mm FR PVC insulated single core multi strand copper conductor of ISI Marked with 20mm dia non-metallic pvc flexible conduit with 6mp, 250 V modular type switch ISI marked and ceiling rose ISI marked mounted on metal with 1.5 sq.mm FR PVC insulated single core multi strand copper conductor as earth wire including all accessories and connection as per direction of Engineer in charge .(Make of wire Finolex/ L&T/ Anchor / Havels / V Guard ) Group C. |
| 44 | Group-A - L.P- F.P- C.B.P- |
| 45 | Group-B - L.P- F.P- C.B.P- |
| 46 | Group-C - L.P- F.P- C.B.P- |
| 47 | Supply and Fixing of 6 Amp plug with 6 Amp Switch ( Modular Type) |
| 48 | Supply and Fixing of Modular Fan Regulator ( Cona/ Anchor/ Bajaj/ Usha) |
| 49 | Supply & fixing of Electronics step type Regulator (Modular Type) |
| 50 | Recessed sub-main wiring along with earth wire with the following sizes of PVC insulated single core multi strand copper conductor ISI marked conforming to IS 694/1990 in 20 mm dia non- metallic heavy duty flexible conduit 1.6 mm in surface / recessed PVC conduit as required ( Make of wire-Finolex/ L&T/ Anchor / Havels / V Guard ) |
| 51 | 2 x 2.5 Sq.mm + 1 x 1.5 Sq.mm |
| 52 | 2 x 4 Sq.mm + 1 x 1.5 Sq.mm |
| 53 | Supply and fixing of following way three pole and neutral, sheet steel, MCB distribution, 415 V on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, hinged front acrylic cover for the MCB knobs detachable gland plate, interconnections, phosphatized and powder painted including earthling etc. as required ( But without MCB/ RCCB/ Isolator)(Make-Hager/Legrand/L&T) |
| 54 | 8 WAY, DOUBLE DOOR, HORIZONTAL TYPE |
| 55 | Supply and Fixing of 16 Amp 02 Nos. & 32 Amp 04 Nos. of rating 240 V \\"B\\" series MCB suitable for Lighting and other loads of the single poles in the existing MCB DB ISI marked complete with connections, testing and commissioning etc. as required. (Make-HPL/Havels/Legrand/L & T) |
| 56 | Supply and fixing of different type of fitting with lamp |
| 57 | Supply and Fixing of 20 Watt 4' LED Fitting surface LED light Fitting ( make- Havels/Fphilips/ Bajaj/ Crompton/Helonix) |
| 58 | Supply and fixing of Exhaust fan(300mm) |
| 59 | Supply and fixing of fan (make-Havels/Philips/Bajaj/Crompton/Helonix) |
| 60 | Supply and Fixing of 1200 mm high speed ceiling fan, Heavy Duty, Durable, Copper Winding, Alluminium Blades. ( make- Havels/Fphilips/ Bajaj/ Crompton/Helonix) |
| 61 | Supply ang fixing of calling bell Please Enable Macros to View BoQ information |