| 1 | Supply, installation, testing and Commissioning of Microprocessor based Intelligent Addressable Main Fire Alarm Control Panel with 2 Loops modules | Supply, installation, testing and Commissioning of Microprocessor based Intelligent Addressable Main Fire Alarm Control Panel with 2 Loops modules and each loop capable of supporting not less than 250 devices AS PER ATTCHED SPECIFICATIONS |
| 2 | Supply, installation, testing and Commissioning of Intelligent Addressable Multi criteria detector with a combination of Optical and Thermal including mounting base | Supply, installation, testing and Commissioning of Intelligent Addressable Multi criteria detector with a combination of Optical and Thermal including mounting base, auto addressing feature as required. Detector should have 2 inbuilt isolators as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance with EFSG agreement EFSG/F/97/005 .Detector should monitor Electromagnetic interference and report to the panel - current and average values. EMC safety for detector shall be 50 V/m. Shall be EN54/ VDs/UL certification. |
| 3 | Supply, installation, testing and Commissioning of Intelligent Addressable smoke detector including mounting base with LED | Supply, installation, testing and Commissioning of Intelligent Addressable smoke detector including mounting base with LED etc. complete as required with 2 inbuilt Isolators as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements, Drift Compensation feature & Automatic addressing. Detector should monitor Electromagnetic interference and report to the panel - current and average values. EMC safety for detector shall be 50 V/m. Shall be EN54- VDs. |
| 4 | Supply, installation, testing and Commissioning of Addressable WEATHER PROOF Outdoor Manual call point with IP rating of IP 67 | Supply, installation, testing and Commissioning of Addressable WEATHER PROOF(Outdoor) Manual call point with IP rating of IP 67 and with inbuilt isolators as per NFPA 72 style 7 wiring requirements, with flexible network structures & necessary fixing arrangements with key complete as required. Shall be EN 54-Vds |
| 5 | Supply, installation, testing and Commissioning of Addressable Loop Powered Stand alone sounder Outdoor with inbuilt isolators | Supply, installation, testing and Commissioning of Addressable Loop Powered Stand alone sounder Outdoor with inbuilt isolators & with 32 different tone variants selection options & adjustable sound pressure by 5 levels, the sound pressure 101.3dB , it should be programmed from the panel. Shall be EN54 - Vds |
| 6 | Supply, installation, testing and Commissioning of Active Repeater panel to be connected peer to peer with Main Fire Alarm panel | Supply, installation, testing and Commissioning of Active Repeater panel to be connected peer to peer with Main Fire Alarm panel. Accept, Reset functions shall be possible from the repeater panel. The user interface of Repeater Panel shall be identical to the Fire alarm Panel. All other specification shall remain unchanged like FACP. Shall be EN54 - Vds |