| 1 | Excavation in foundation and trenches etc.(in pipes and pits) in all kinds of soils such as pick work, jumper work, blasting in soft/hard rock, chiselling/wedging out of rock/where blasting prohibited) saturated soil stacking the excavated soil as directed by the Engineer-in-charge clear from the edge of excavation and then returning the stacked soil in 15cm layers when required into plinth sides of foundation etc. consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated earth as directed by the Engineer –in-charge in all leads and lifts. |
| 2 | Providing and laying cement concrete 1:5:10 (1 Cement: 5 Sand:10 Graded stone aggregate 40mm nominal size) and curing complete excluding the cost of form work foundation and plinth complete in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge |
| 3 | Providing and laying cement concrete work using concrete mix of \\"M-20\\" ( 1:1.5:3 ) graded stone aggregate 20mm & down gauge nominal size) and curing complete excluding the cost of form work and reinforcement for reinforced concrete work in:- |
| 4 | Foundation,footing,bases of columns & the like & mass concrete complete in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge |
| 5 | Columns,pillars,posts & struts upto floor two level complete in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge |
| 6 | Brick work using common burnt clay building bricks (IInd class) in super structure above plinth level upto floor two level in cement mortar 1:6 (1cement:6 sand) complete in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge |
| 7 | Providing and Fixing anodised aluminium work (JINDLE MAKE) for door,window,ventilators and partition with extruded built up standard tubular and other sections of approved make confirming to IS 733 and IS 1285 anodised transparent or dyed to required shade according to IS 1868.(minimum anodic coating of grade AC 15) fixed with rawl plug and screws or with fixing clips,or with expansion hold fastener including necessary filling up of gaps at junctions at top,bottom and sides with required PVC.neoprene felt etc. Aluminium section shall be smooth rustfree,straight,mitred and jointed mechanically where ever required including cleast angle,aluminium,snap beading for glazing/panelling C.P. brass/stainless steel screws . All complete as per architectural drawings and the complete in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge |
| 8 | Providing and fixing anodized aluminium shutters of doors,windows & ventilators including providing and fixing hinges/pivots and making provision for fixing of fittings whereever required including the cost of PVC/neoprene gasket as required (fittings and glazing/panelling shall be paid for separately) complete in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge |
| 9 | Providingand fixing anodised alluminium wire gauge shutters for doors and windows complete in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge |
| 10 | P/F aluminium Grills of required pattrens including fixing with steel screws complete in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge |
| 11 | Providing form work with steel plates 3.15mm thick welded with angle iron in frame 30x30x5mm, so as to give a fair finish including centring, shuttering , strutting and propping etc. with wooden battens and ballies height of propping and centering below supporting floor to ceiling not exceeding 4meters and removal of the same for insitu reinforced concrete and plain. |
| 12 | Flat surfaces such as soffits of suspended floors, roofs, landings and the like floors upto 200mm kin thickness complete in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge |
| 13 | Beams,cantilevers,girders & lintels, sides & soffits of beams, haunching, cantilevers, bressumers 1.00 mts. In depth in all heights from floor complete in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge |
| 14 | Edges of slabs and breaks in floors & walls under 20 cms. Wide complete in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge |
| 15 | Providing and laying cement concrete work using concrete mix of \\"M-20\\" (1:1.5:3) graded stone aggregate 20mm & down gauge nominal size) and curing complete excluding the cost of form work and reinforcement for reinforced concrete work in:- |
| 16 | Suspended floors, roofs, landings and shelves and their supports, balconies, beams ,griders bressumers and cantilevers upto all floor level complete in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge |
| 17 | Providing and laying cement concrete work using concrete mix of \\"M-20\\" (1:1.5:3) graded stone aggregate 20mm & down gauge nominal size) and curing complete excluding the cost of form work and reinforcement for reinforced concrete work in:- |
| 18 | Lintels, beams ,griders bressumers and cantilevers upto all floor level complete in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge |
| 19 | Providing and Fixing 10mm thick anti skid water proof stain and impact resistance heavy duty vetrified tiles (NITCO or equivalant make) 600x600mmx10mm manufactured of approved shade and colour in flooring,treads of steps and landings laid over 12mm thick cement mortar 1:3(1 Cement :3 Sand) jointed with cement slurry mixed with pigment to match the shade of tiles as required complete in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge |
| 20 | 20mm cement plaster in single coat of rough sides of bricks/concrete stone walls for interior plastering upto floor two level including arrises internal rounded angles chamber and rounded angles not exceeding 80mm in girth and finished even and smooth in cement mortar 1:6(1cement:6sand) complete in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge |
| 21 | Pointing on brick masonry in cement mortor 1:3 (1 cement:3 sand) RULED complete in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge |
| 22 | 6 mm cement plaster to ceiling in CM 1:4 (1Cement :4 Sand) complete in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge |
| 23 | Providing plinth protection 50mm thick in cement concrete 1:3:6 (1cement:3sand:6 graded stone aggregate 20mm nominal size) including finishing of the top surface of concrete smooth in complete in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge |
| 24 | Providing under layers for plinth protection of 75 mm thick( unconsolidated) bed dry brick / stone aggregated 40 mm nominal size will rammed & consolidated & grouted with fine sand including preparation of gruond complete in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge |
| 25 | Providing Tor steel reinforcement for RCC work including bending,binding & placing in position complete upto floor two level complete in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge |
| 26 | Steel work welded in built up sections, including cutting sections, including cutting, hoisting, fixing in position and applying a priming coat of red lead paint In gretings, framed guards, bars ladders railings brackets and similar works complete in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge |
| 27 | Providing/Fixing 0.60mm thick prepainted steel sheet (TATA make)in roofing with hot dipped metallic zinc coated sheet with top coat of regular modified polyester (RNP) organic coating of 20 microns over 5 microns primer coating to back coat of polyester of 5 micron over 5 micron primer coating including fixing with prepainted iron J or L hooks, bolts & nuts 6mm dia with prepainted limpet and rubber washers complete with all accessories as required complete in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge |
| 28 | Providing/Fixing ridges or hips 60cm overall with 0.60mm thick prepainted steel (TATA make) sheets in roofing with hut dipped metallic zinc coated sheets with top coat of regular modified polyesters organic coating of 20 microns over 5 microns primer coating + back coat of polyster of 5 microns over 5 microns primer coating including fixing with prepainted iron J or L hooks, bolts & nuts 6mm dia prepainted G.I. limpet and bitumen washer complete with all accessories as complete in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge |
| 29 | White washing with lime on undecorated walls surface (two coats) to give an even shade including thoroughly brooming the surface dirt dust mortar dirt and other foreign matter in complete in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge |
| 30 | Finishing wall with water proofing cement paint of approved brand & manufacture & of required shade on undecorated wall surfaces (two coats) to give an even shade after thotoughly brushing the surface to remove all dirt & remains of loose powdered materials. complete in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge |
| 31 | Providing and fixing M.S.fan clamp (Type-I of 16mm dial M.S. Bar bent to shape with hooked ends in RCC. Slab during laying including painting the exposed portion of loop all as per standard design complete in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge |
| 32 | Providing 40x3mm flat iron hold fast 40cm long including fixing to frame with 10mm dial meters bolts and nuts and wooden plug and embeding in cement mortar block 30x10x15cm (1:3:6(1cement:3sand:6 graded stone aggregate 20mm nominal size. complete in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge |
| 33 | Providing and fixing following anodized aluminium fittings of anodized transparent and shade with necessary screw etc complete in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge |
| 34 | (a) Sliding door bolts 250x16mm. |
| 35 | (b-i) M.S. tower bolts (Barrel type) leads and lifts. 200x10mm. |
| 36 | (b-ii) M.S. tower bolts (Barrel type) leads and lifts. 150x10mm. |
| 37 | (b-iii) M.S. tower bolts (Barrel type) leads and lifts. 100x10mm. |
| 38 | (c-i) M.S. handles 125mm dia |
| 39 | (c-ii) M.S. handles 100mm dia |
| 40 | Stone/Boulder filling under floors/behind retaining walls complete in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge |
| 41 | Construction of PCC drain concrete mix of 1:3:6 (1 cement: 3 sand: 6 graded stone aggregate 20 mm nominal size) and curing complete including cost of centring and shuttering in Foundation and Plinth (size 450 x 450 mm) complete in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge |
| 42 | Construction of PCC drain concrete mix of 1:3:6 (1 cement: 3 sand: 6 graded stone aggregate 20 mm nominal size) and curing complete including cost of centring and shuttering in Foundation and Plinth (size 300 x3 00 mm) complete in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge |
| 43 | Providing & fixing Flood Light in all accessories complete within all leads & lifts as per entire satisfaction of Engineer in Charge. |
| 44 | Providing and fixing 5.00 Ton gantry of approved ISI make electrically operated alongwith all allied accessories complete within all leads & lifts as per entire satisfaction of Engineer in Charge. |
| 45 | Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required Group-B complete in all respect as per the direction and to the entire satisfaction of the Engineer-in-charge in all leads and lifts. |
| 46 | Wiring for Circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No. HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required complete in all respect as per the direction and to the entire satisfaction of the Engineer-in-charge in all leads and lifts. |
| 47 | 2x1.5 Sq. mm. |
| 48 | 2x4.00 Sq. mm. |
| 49 | 2x6.00 Sq. mm. |
| 50 | Supplying and fixing following rating Piano-type switch /socket on the existing switch box / cover including connections etc. as required complete in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge |
| 51 | S.P. 15/16 Amps one way switch, porcelain base/ piano type |
| 52 | S.P 15/16 Amps socket outlet, porcelain base/ piano type. |
| 53 | Bell push , piano type. |
| 54 | Supplying & fixing metal box of following sizes (nominal size) on surface or in recess suitable for fixing phenolic laminated sheet cover in front including painting etc. as required complete in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge |
| 55 | 180mm.x100mm.x60mm. deep |
| 56 | 250mm.x300mm.x100mm. deep |
| 57 | Supplying and erection of 40/50/63 amps rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of followingpoles in theexistingMCBDBcomplete with connections etc. as required complete in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge |
| 58 | Double Pole Cat-A |
| 59 | Supplying and erectionof6 amps. to32amps. rating,10KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of followingpoles in theexistingMCBDBcomplete with connections etc. as required complete in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge |
| 60 | Single pole Cat-A |
| 61 | Supplying and fixing following rating, double pole (single phase & neutral )240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 miliampers in theexisting MCB DB complete with connections, testing and commissioning etc. as required complete in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge |
| 62 | 63 Amps. Cat-A. |
| 63 | Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wireset, neutral link, earth bar, din-bar, detachable gland plate blanking plate, cable, identification labels interconnections,phosphatized and powder painted, including earthing etc. as required:- |
| 64 | Single door-12 way |
| 65 | Wiring for twin control light point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit with2-way, 5/6amps. piano type switch and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required complete in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge Group - A |
| 66 | Supplying and fixing ceiling rose on the existing junction box / wooden block including connections etc. as required complete in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge |
| 67 | Supplying and fixing bakelite batten/angle holder including connections etc. as required complete in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge |
| 68 | Providing and installation of exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required complete in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge |
| 69 | Exhaust Fan, Light duty, (Domestic) 300 mm sweep Please Enable Macros to View BoQ information |