| 1 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width aswell as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge.All kinds of soil (DSR No. 2.6.1) |
| 2 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. (DSR No. 2.25) |
| 3 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. (DSR No. 225a) |
| 4 | Sand filling in plinth under floors including watering, ramming, consolidating and dressing complete including lead up to 50m and lift upto 1.5m and including cost of sand. (DSR No. 2.27) |
| 5 | Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded stone aggregate 40 mm nominal size) and curing complete,including cost of form- work, in foundation and floors. (DSR No. 4.1.8) |
| 6 | Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and around the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per I.S.6313(PartII 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1)Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm (4) Treatment of soil along external perimeter of building 7.5 liters/sqm. (5) Treatment of soil under apron along external perimter 5 liters/sqm. (DSR No. 2.35.3) |
| 7 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR No. 5.1.2) |
| 8 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chaijjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR No. 5.3) |
| 9 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR No. 5.2.2) |
| 10 | Class 150 brick work in 1:6 (one cement and six coarse sand sand of 2.25 fineness modulus) mortar in foundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. (DSR No. 6.1.2) |
| 11 | Brick work in super-structure above plinth level up to floor two level (up to two storeys) including necessary cutting and moulding of bricks as required and also including honey comb brick work thickness of wall not to be less than 1.5 brick thick. (1:6 cement & coarse sand) DSR No. 6.4.2) |
| 12 | Half brick masonry with (Class M-150 First Class Brick) in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand) (DSR No. 6.13.2) |
| 13 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size) (DSR No. 4.10) |
| 14 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. (DSR No. 4.13) |
| 15 | Providing and laying \\"brick coba\\" 120mm thick laid with M-150 class brick bat coba 7.50cm thick with gap of 15mm to each other, over 20 mm thick base of cement mortar 1:4 cement and coarse sand mixed with water proofing compound spreading cement slurry mixed with acrelic cement concrete water proofing compound filled gaps of coba & top of coba mortar mixed with water proofing compound in 1:4 cement and coarse sand mortar finised smooth & top mashed false square 30 cm x 30 cm and side wall parapet shall be mono tythic plaster wall up to 30 cm higher and junction and corner shall be rounded by brick ballast cement and coarse sand masonany Coba with top finised plaster mixed with acetic water proofing compound @ 2% by weight & including s/o all material, labour, T& P etc complete for proper completion of work. (DSR No. 22.7.1) |
| 16 | Supply & fixing of flush door commercial quality conforming to I.S. : 2202 Part I (1983) including fixing of wooden cleats & stopper and including fixing and adjustment of hinges , Bolts locks , handles , springs , fitting with necessary screws to be supplied departmentally.Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) Both SIde Laminated (35mm thick) (DSR No. -9.21.1+9.22.1*2) |
| 17 | Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) (DSR No. 9.23) |
| 18 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) (DSR No. 10.15.1) |
| 19 | Providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws 35 mm thick shutters Second class teak wood. DSR No. 9.134.1.2.1) |
| 20 | Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete. With 2nd class teak wood beading 62X19 mm. (DSR No. 9.51.1) |
| 21 | TMT Fe-500 steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of all steel and and over lapping & hooks. (DSR No. 5.22.6) |
| 22 | 15mm thick plaster with cement mortar in proportion of 1:4 cement & coarse sand of 2.25 F.M. (DSR No. 13.5.1) |
| 23 | 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 coarse sand. F.M.-2.25 (DSR No. 13.4.2) |
| 24 | 15 mm cement plaster in single coat on rough side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 coarse sand. F.M.-2.25 (DSR No. 13.5.2) |
| 25 | 12mm thick plaster in 1:3 cement & coarse sand on ceiling and soffits of stairs upto floor two level. (DSR No. 13.9.1) |
| 26 | Making grooves 10 to 12 mm widex 8mm deep in plaster of the wallor in ceiling vertically or horizontally as required. (DSR No. 13.76) |
| 27 | Making drip Coarse in sunshade & Parapet. (DSR No. 5.30) |
| 28 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm (DSR No. 11.41.2) |
| 29 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm (DSR No. 11.46.2) |
| 30 | Supply and fixing 6 mm (1/4\\") thick China glazed tiles in flooring or in skirting or dado laid with 1:3 cement and approved coarse sand mortar finished with white cement slurry jointing and polishing complete including supply of all materials, labour and tool sand plants etc. required for proper completion of the work. Anti Skid Tiles (DSR No. 11.37A) |
| 31 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick. (DSR No. 11.26.1) |
| 32 | Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. (DSR No. 11.27) |
| 33 | Providing and fixing 18 mm thick gang saw cut, mirror polished,premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc.Area of slab over 0.50 sqm [ Granite ] (DSR No. 8.2.2.2) |
| 34 | Providing edge moulding to 18 mm thick Granite stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge (DSR No. 8.3.1) |
| 35 | Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (40 mm thick floor). (DSR No. 11.3.1) |
| 36 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). (DSR No. 11.20.1) |
| 37 | Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 40 mm wide and 4 mm thick (DSR No. 11.13.1) |
| 38 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture (DSR No. 13.62.1) |
| 39 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) with base of wall putty (DSR No. 13.47.1) |
| 40 | Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials. (DSR No. 13.41.1) |
| 41 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (DSR No. 13.80) |
| 42 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes (DSR No.10.30.1) |
| 43 | Providing & fixing S.S. sliding door bolts ISI marked to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm (MR) |
| 44 | Providing and fixing S.S. Steel tower bolts with necessary screws etc. complete (a) 250mm x 10mm. (MR) |
| 45 | (b) 200mm x 10mm. (MR) |
| 46 | Providing and fixing S.S. Steel handles with screws etc. complete (a) 125 mm (MR) |
| 47 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete (DSR No. 9.82) |
| 48 | Providing and fixing ISI marked Oxidised iron tower bolt with 10 mm dia and screw. (for Window) (i) 100 mm long (DSR No. 9.63.4) |
| 49 | Providing and fixing ISI marked Oxidised iron door handles with screws 100 mm long. (for Window) (DSR No. 9.66.2) |
| 50 | Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete 250 mm weighing not less than 150 grams (DSR No. 9.68.2) |
| 51 | Providing and fixing ISI marked bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. (DSR No. 9.76) |
| 52 | Providing and fixing ISI marked aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete (DSR No. 9.83) |
| 53 | Providing and fixing ISI marked magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete. Triple strip (horizontal type) (DSR No. 9.114.1) |
| 54 | Providing & laying of light cinder filling under floor of toilets & other sunken roofs. (MR) |
| 55 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. (DSR No. 22.5) |
| 56 | P/F curtain rods of 1.25mm thick chromium plated brass plate, with two chromium plated brass brackets fixed with C.P. brass screws and wooden plugs etc. wherever necessary complete (a) 25 mm dia.(DSR No. 9.46.3) |
| 57 | 25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. Piano hinges IS : 3818 marked with necessary screws with Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) both side laminated. (DSR No. 9.20.3+ 9.22.1*2) |
| 58 | Centering and shuttering including strutting, propping etc. and removal of form for all heights :(a) Foundations, footings, bases of columns, etc. for mass concrete. (DSR No. 5.9.1) |
| 59 | Columns,Pillars, Piers, Abutments, Posts and Struts. (DSR No. 5.9.6) |
| 60 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. (DSR No. 5.9.5) |
| 61 | Suspended floors, roofs, landings, balconies and access platform.(DSR No. 5.9.3) |
| 62 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid (DSR No. 17.3.1) |
| 63 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer (DSR No. 17.7A) |
| 64 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. (DSR No. 17.22A) |
| 65 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.(DSR No. 17.72) |
| 66 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :100 mm diameter (DSR No. 18.22.1) |
| 67 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. (DSR No. 17.73.2) |
| 68 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. (DSR No. 18.65) |
| 69 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 (including angle valve for WC flushing cistern, jet & kitchen sink) 15 mm nominal bore (DSR No. 18.53.1) |
| 70 | Providing and fixing uplasticised PVC connection pipe with brass unions : (a) 45 cm length 15 mm nominal bore (DSR No. 18.21.2.1) |
| 71 | Providing and fixing Stainless Steel AISI 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required Kitchen sink with drain board 510x1040 mm bowl depth 200 mm (DSR No. 17.10.1.3) |
| 72 | Providing & fixing PVC waste pipe for sink including PVC waste fittings Complete Flexible Pipe (a) 32mm Dia (DSR No. 17.28.2.1) |
| 73 | (b) 40mm Dia (DSR No. 17.28.2.2) |
| 74 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. (DSR No. 17.31) |
| 75 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :15mm nominal bore (DSR No. 18.49.1) |
| 76 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15mm nominal bore (DSR No. 18.51.1) |
| 77 | Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. 15mm nominal bore (DSR No. 17.22B) |
| 78 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. For Internal Toilet (a) 15 mm nominal outer dia Pipes (DSR No. 18.8.1) |
| 79 | (b) 20 mm nominal outer dia Pipes (DSR No. 18.8.2) |
| 80 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 20 mm nominal bore (DSR No. 18.7.2) |
| 81 | Providing and fixing CPVC pipes complete with CPVC fittings and clamps, including cutting and making good walls etc. (internal work).(a) 15mm dia nominal bore (DSR No. 18.7.1) |
| 82 | © 25mm dia nominal bore (DSR No. 18.7.3) |
| 83 | (d) 32mm dia nominal bore (DSR No. 18.7.4) |
| 84 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : For vertical pipe connection with terrace ring main (a) 20 mm nominal bore (DSR No. 18.17.1A) |
| 85 | (b) 25mm nominal bore (DSR No. 18.17.1) |
| 86 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (DSR No. 18.48) |
| 87 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm dia (for rain water) (DSR No. 12.41.2) |
| 88 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. (a) Single Push Fit Coupler 110 mm dia (DSR No. 12.42.2.2) |
| 89 | (b) Plain bend 87.5 deg 110 mm dia (DSR No. 12.42.5.2) |
| 90 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm dia (DSR No. 12.43.2) |
| 91 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. (DSR No. 12.22) |
| 92 | Providing and fixing PTMT grating of approved quality and colour.Circular type 100 mm nominal dia (DSR No. 18.58.1.1) |
| 93 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design :150 x 100mm size P-type With common burnt clay F.P.S. (non modular) bricks of class designation M-150 (DSR No. 19.4.2.1) |
| 94 | Excavating trenches of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m ncluding getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m.All kind of soil Pipes, cables etc. exceeding 80 mm dia . But not exceeding 300mm dia. (DSR No. 2.10.1.2) |
| 95 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round pipes including bed concrete as per standard design110mm dia Pipe: (DSR No. 19.2.1) |
| 96 | Excavation in Foundation in ordinary soil (Loam clay, or sand) including lift upto 1.5 metre (5 fts.) and lead upto 30m (100 fts) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-in-charge upto a distance of 30 m. (100 fts) from the foundation trenches. (Rate is including Royality). (a) From 0.00 mt to 1.50 mt 1.50mt to 3.0 mt (DSR No. 2.8.1) |
| 97 | (b) 1.50mt to 3.0 mt (DSR No. 2.8.1+2.26.1) |
| 98 | Providing and laying in position ready mixed or site batched design mix cementconcrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/ Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cementcontent, the contractor shall have discretion to either re-design the All works upto plinth level :mix or bear the cost of extra cement. Concrete of M10 grade with minimum cement content of 220 kg /cum (DSR No. 4.20.1.1) |
| 99 | Providing and fixing soil, waste and vent pipes : 75mm diameter : Sand cast iron S&S pipe as per IS: 1729 (DSR No. 17.35.2.1) |
| 100 | Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design:(With 20x20mm square bar) (DSR No. 19.15.1) |
| 101 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR No. 19.32.1) |
| 102 | Providing and fixing angle iron frames for doors, windows and ventilators\ of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. (DSR No. 10.31) |
| 103 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. (DSR No. 10.25.2) |
| 104 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. (DSR No. 16.91.2) |
| 105 | Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres. (DSR No. 16.10) |
| 106 | Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineerin- charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately). Note:- Cement content considered in M-30 is @ 340 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately. Cement concrete prepared with batch mixing machine (DSR No. 16.43.2) |
| 107 | Cutting of grooves in C.C. including Providing and laying in position bitumen hot sealing compound for expansion joints etc. Using grade 'A' sealing compound (MR) |
| 108 | Providing and laying 200 Micron Dust proof waterproof Plastic Polythene Sheet (MR) Please Enable Macros to View BoQ information |
| 109 | Providing and laying 200 Micron Dust proof waterproof Plastic Polythene Sheet (MR) Please Enable Macros to View BoQ information |