| 1 | Removing existing water proofing treatment by brushing with wire brush, cleaning of terracing by taking down cement concrete, existing plaster lime cova 80 to 100mm thick mud phuska/cement concrete/lime coba etc, cleaning of all foreign material such as fungus mass dust etc, roughing surface of corner to roof by wire brush complete all as specified and directed. |
| 2 | M&L water proofing treatment to roof slab with APP based modified polymeric membrane centre core 100 microne HMHDPE outer flim 20 micron, five layer polymeric membrane 3mm thick weight not less than 3kg/Sqm with 100mm overlap laid as per manuacturer's instructions complete all as specified and as directed by Engineer-in-Charge with following course of description below:- (a) 1st coat applying bitumen primer confirming to IS-3384-1965 @ 0.40 Kg/Sqm to be applied on prepared roof surface till the surface is properly impregnated(b) 2nd coat of bonding material using blown type bitumen conforming to IS-702 of grade 85/25 @ 1.20 Kg/Sqm(c) 3rd course of laying of APP Based modifiedpolymeric membrane with 100mm overlap in longitudinal direction and 150mm in transverse direction and edges to be taken up to vertical wall of 20cm height inserted into the vertical wall concealed the joints with bitumen sealed. All joints and changes in all direction should be covered with cement mortar (1:3) mixed with SBR latex @ 200ml per bag of cement and cured well before laying the membrane.Note:- (i) The work shall be executed through authorised applicator of main manufacturer as approved by GE.(ii) Top layer of Aluminium paint or cement concrete tiles shall be measured and paid under seperate item. |
| 3 | M&L for Applying a coat of bituminous aluminium paint @ 0.20 Kg/Sqm over APP membrance, complete all as specified and directed |
| 4 | M&L for Cement concrete tiles 25cm x 25cm x 20mm thick, machine pressed; set jointed and pointed in neat cement slurry in floors with grey cement on pigment over 15 mm thick screed/ bedding layer in CM (1:6) complete all as specified and as directed. |
| 5 | M&L for PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) as in roof kerbs or mud stops round or chamfered on edges complete all as specified and directed. |
| 6 | M&L for 10 mm thick rendering in CM (1:4) mixed with water proofing compound @ 0.20 Ltr/bags on roof surface after removing all dust and cleaning the surface with water through jet spray complete all as specified and directed. |
| 7 | Supply only liquid water proofing compound, mixed in CM as per manufacturer instruction, complete all as specified and directed. Make : Dr Fixit LW or equivalent approved as per list of makes |
| 8 | S&F of rotational moulded polyethylene cylindrical vertical with closed top water storage tank triple layered WHITE COLOUR 500 Ltr capacity with connecting nipple, hoisted and fixed in position on new or existing foundation and making GI tubing inlet or outlet connection, with and incl disconnecting and dismantling the existing un-serviceable PVC/RCC water tank on top of roof/slab of bldgs, complete all as specified and directed. |
| 9 | S&F of rotational moulded polyethylene cylindrical vertical with closed top water storage tank triple layered WHITE COLOUR 1000 Ltr capacity with connecting nipple, hoisted and fixed in position on new or existing foundation and making GI tubing inlet or outlet connection, with and incl disconnecting and dismantling the existing un-serviceable PVC/RCC water tank on top of roof/slab of bldgs, complete all as specified and directed. |
| 10 | Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning etc. and hoisting, reconnecting and re-fixing in position of exc. 250 litres & not exc. 500 litres capacity of tanks,Date of cleaning of tank will be marked on the tank by stencil with synthetic enamaled paint in uniform size, Size of letters & numbers should be 40mm. complete all as specified and directed. |
| 11 | Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning etc. and hoisting, reconnecting and re-fixing in position of 1000 litres capacity of tanks, Date of cleaning of tank will be marked on the tank by stencil with synthetic enamaled paint in uniform size, Size of letters & numbers should be 40mm. complete all as specified and directed. |
| 12 | S&F in replacement of 20 mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed, complete all as specified and directed. |
| 13 | S&F in replacement of 20 mm dia of Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iorn pipe and fixed. (minium weight 20 mm-210 gms) etc, complete all as directed. |
| 14 | Demolition of cement concrete of any description and in any position of WC’s/Bathroom etc in sunken portion area above ground floor, removing demolished material completely and old waste pipe from sunken portion and cleaning the side/bottom surface of sunken floor with wire brush, complete all as specified and directed. |
| 15 | M&L for application/forming of waterproofing liquid membrane moistening the prepared surface for proper dispersion and penetration and applying two component cementitious elastomeric water proofing coating damp block 2k as per manufacturers specifications. The treatment shall be carried out to the entire bottom surface and vertical surface upto the bottom height of wall tiles. Adequate curing to be done on vertical surfaces and ponding test for 48 hours on the bottom surface to be carried out complete all as specified and directed. Make :- M/s Asian paint, M/s fosroc, M/s Sikka, M/s BIS |
| 16 | M&L for 25 mm thick PCC 1:2:4 type B0 using 12.5 mm graded stone aggregate as in padding levelling etc and roof kerbs with liquid water proofing solution finished even and fair with proper slope as prepatory works to water proofing treatment complete all as spd and directed by EIC.Note:-liquid water proofing solution shall be provided in 150ml in 50 Kg of Cement by weight and cost of liquid water proofing solutionmeasured and paid under seperate item complete all as directed. |
| 17 | M&L PCC 1:5:10 Type E2 using 40mm graded stone aggregate as in mass filling in two layer in sunken portion complete all as spd and directed |
| 18 | M&L 10mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:4 floor finising with WPC finished even & smooth complete all as specified and directed.Note:- liquid water proofing solution measured and paid seperate item complete all as specified and directed. |
| 19 | M&L 50mm dia G.I pipe as in spout to drain out if any leakage occures in the sunken portion complete all as spd |
| 20 | S&F in repair Vitreous China wash basin, white, flat back, size 550x400mm excluding taps, waste chain and plug and porcelain stopper but including brackets, CP waste coupling, 32 mm PVC Waste pipe 600mm long complete all as specified and directed |
| 21 | S&F Vitreous China squatting pan, 'Orissa pattern', size 580x440mm, white, with integral foot rests including cast iron 'P' or 'S' trap, excluding flushing cistern and flush pipe, including connection to trap and flushing pipe etc. and making good to floor complete all as specified and directed. |
| 22 | Supply & Fix in repairs Vitreous China wash down water closet pan (pedestal pattern), EWC, coloured including jet system & matching coloured seat cover fixed complete all as specified. |
| 23 | Supply and Fixing 10 Litres, PVC, valve less, syphonic action type, Flushing Cistern, low level, white inlet, ball valve, float, chain and pull, and brackets including PTMT PVC connection 600mm long and PVC 32 mm dia flush pipe. |
| 24 | S&F 15 mm bore Galvanized Steel tubes, medium grade with fittings fixed to walls and ceilings or laid in floors, concealed or open incl cutting of grooves Including taking down old GI pipe & Fitting all as specified and directed |
| 25 | S&F 20 mm bore Galvanized Steel tubes, medium grade with fittings fixed to walls and ceilings or laid in floors, concealed or open incl cutting of grooves Including taking down old GI pipe & Fitting all as specified and directed |
| 26 | Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises, complete all as specified and directed. |
| 27 | M & L for Non- skid Ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed/ bedding layer in CM (1:6) complete all as specified and as directed. |
| 28 | M&L for Glazed ceramic coloured tiles invertical surface 350x 250x 7mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match tiles with and including 10 mm thick rendering in CM (1:4) for receiving the tiles, complete all as directed. |
| 29 | Taking down of eaves gutter and rain / waste water pipes including all fittings any size and pattern, complete all as specified and directed. |
| 30 | S&F for 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 31 | S&F for 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 32 | S&F for 110 mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed. |
| 33 | S&F for 75 mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed. |
| 34 | S&F in repairs 110 mm bore PVC (SWR) bends of any radius, complete all as specified and directed. |
| 35 | S&F in repairs 75 mm bore PVC (SWR) bends of any radius, complete all as specified and directed. |
| 36 | S&F 110 mm bore PVC (SWR) junction single (Single `T') equal or unequal, complete all as specified and directed. |
| 37 | S&F 75 mm bore PVC (SWR) junction single (Single `T') equal or unequal, complete all as specified and directed. |
| 38 | S&F PVC (SWR) vent cowl 75mm bore, jointing to waste pipe, complete all as specified and directed. |
| 39 | S&F PVC (SWR) vent cowl 110mm bore, jointing to waste pipe, complete all as specified and directed. |
| 40 | S&F in repairs PVC (SWR) floor trap of 75 mm outlet, jointing to waste pipe, complete all as specified and directed. |
| 41 | S&F in repairs PVC (SWR) gully trap 125/110mm, setting and jointing with solvent cement, complete all as specified and directed. |
| 42 | Demolition of brick work built in cement mortar or lime mortar including all quoins arches, pillars etc complete all as specified and directed. |
| 43 | M&L for Brick work with sub class 'B' bricks (old size) straight or curved on plan exc 6.00m mean radius built in cement mortar (1:6) complete all as specified and directed. |
| 44 | Taking down cement plaster on brick or stone wall,dado and skirting etc including racking out joints hacking for key scrubbing down with water etc, complete all as specified and directed. |
| 45 | M&L for 15mm rendering thick in CM (1:4) on fair faces of brick work/concrete surfaces finished even & smooth (without using extra cement), complete all as specified and directed. |
| 46 | M&L for preparation of primed surfaces of wall / ceiling and applying one coat of premium external emulsion paint of VOC less than 50 and with silicon additives, dust and water repellent properties complete all as specified and directed. |
| 47 | S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 including demolition of existing PCC Platform complete all as specified and directed. |
| 48 | M&L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed Please Enable Macros to View BoQ information |