| 1 | Dismantling wrought iron or mild steel work of any description complete all as specified and directed. |
| 2 | M & L for mild steel framed work such as grills, grating cooler stands, etc, with ends of bars shouldered and / or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railing, frame work of water tanks and similar work conforming to Fe 290 Gde E-165 complete all as specified and directed. |
| 3 | M&L for preparation of new steel surfaces over 10 cm width or girth & applying two coats of synthetic enamel paint of 1st quality over a coat of red oxide primer complete all as specified and directed. |
| 4 | Dismantling Asbestos Cement (corrugated, semi corrugated, etc) sheets in roof covering complete all as specified and directed. |
| 5 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws and making good to disturb surface, complete all as specified and directed. |
| 6 | S & F Pre-painted galvalume aluminum zinc coating GI based Profile sheet (ridge) 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding/ridge to wall, fixed with self tapping screws complete all as specified and directed. |
| 7 | M & L for cement concrete (Type B0, 1:2:4, 12.5 mm graded aggregate) in copings, kneelers, apex stones, bed plates, water troughts and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed. |
| 8 | Taking down existing tar felt or of any description including cement plaster or concrete of any thickness from the roof surfaces of building including cleaning the surfaces in all respect & preparing it for further treatment & removing rubbish from site complete all as specified and directed. |
| 9 | M&L for rendering 10mm thick in CM 1:4 mixed with water proofing compound @ 3% by weight of cement on fair faces of RCC/stone patti roof surfaces finished even & smooth without using extra cement complete all as specified and directed. |
| 10 | M&L for cutting out cracks to 'V' section in existing roofs or terracing, cleaning out and filling solidly with hot mixture of bitumen and clean dry sand 1:1(by weight ) complete all as specified and directed. |
| 11 | M&L roof treatment with APP modified polymeric water proofing membrane, 2mm thick having centre core not less than 100 mircron high molecular high density polyethylene film (HMHDPE) protected on both sides with high polymeric asphaltic mix and 20 mircron HMHDPE film weight not less than 2.60 kg/ Sqm applied with bonding material using blown type bitumen primer Grade 85/25 @ 1.20 Kg/Sqm over bitumen primer conforming to IS -3384 @ 0.40 Kg /Sqm with final coat of bonding bitumen grade 85/25 @ 1.20 Kg /Sqm over APP membrane with all overlaps complete all as specified and directed. |
| 12 | Material and labour for 40mm thick (avergae consolidated thickness) PCC (1:2:4) type B-0 using 12.5mm graded stone aggregate laid in slope as in padding, finished even and smooth on existing slope including provision of 'V' shaped groove 6mm wide and 10mm deep at 1.20 metre interval or parts thereof, both ways on top of PCC padding and filled with mastic bitumen of (1:1) proportion complete all as specified and directed. |
| 13 | Disconnecting existing water tanks, setting asides ( or lowering if required) for repairs, cleaning and removing all scale and dirt etc from tanks, and from mouth of circulating pipes etc and re-fixing reconnecting in same position, of capacity exc 250 ltrs and not exc 500 ltrs each etc complete all as specified and directed. |
| 14 | Disconnecting existing water tanks, setting asides ( or lowering if required) for repairs, cleaning and removing all scale and dirt etc from tanks, and from mouth of circulating pipes etc and re-fixing reconnecting in same position, of capacity exc 500 ltrs and not exc 1000 ltrs each etc complete all as specified and directed. |
| 15 | S&F in repair rotational moulded polyethylene water storage tanks of 1000 Ltrs capacity (cylindrical vertical with closed top), Triple layer,hoisted and fixed in position complete all as specified and directed. |
| 16 | S&F in repair rotational moulded polyethylene water storage tanks of 500 Ltrs capacity (cylindrical vertical with closed top), Triple layer,hoisted and fixed in position complete all as specified and directed.(Make: Sytex, Polycon) |
| 17 | S&F in repair 20mm dia ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 210 grams) complete all as specified and directed. |
| 18 | Taking down old unserviceable 15mm GI tubing, fittings and connections and removing from site or keeping aside for refixing complete all as specified and directed. |
| 19 | Taking down old unserviceable 20mm GI tubing, fittings and connections and removing from site or keeping aside for refixing complete all as specified and directed. |
| 20 | S&F 15mm GI water tubing( Concealed type), medium grade, galvanised with all fittings ( and fixed to walls, ceiling or laid in floors/ trenches complete all as specified and directed. |
| 21 | S&F 20mm GI water tubing, medium grade, galvanised with all fittings ( and fixed to walls, ceiling or laid in floors/ trenches complete all as specified and directed. |
| 22 | Refixing old 15mm GI tubing (Concealed type) galvanised with new fittings and fixed to walls, ceiling or laid in floors, trenches including necessary cleaning, cutting, screwing complete all as specified and directed. |
| 23 | Refixing old 20mm GI tubing galvanised with new fittings and fixed to walls, ceiling or laid in floors, trenches including necessary cleaning, cutting, screwing complete all as specified and directed. |
| 24 | S & F in repairs Roof tiles, Mangalore pattern, interlocking at side joints, laid dry, complete all as specified and directed. |
| 25 | Taking down cement or cement lime plaster or stone / brick wall, ceiling including racking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed. |
| 26 | M&L 15mm thick rendering in cement mortar (1:4) on other than fair faces of brick / stone masonary surfaces, finished even and smooth without using extra cement, mixed with WPC, complete all as specified and directed. |
| 27 | M&L for newly plastered surfaces two coats of cement base paint over one coat of cement based primer on plastered/ concrete surfaces of walls including preparation of surfaces complete all as specified and directed. |
| 28 | Demolition of brick work or stone masonary built in cement mortar etc complete all as specified and directed. |
| 29 | M&L for brick work with flyash bricks, straight or curved on plan exc 6M mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 30 | Taking down 100mm / 75mm dia AC/PVC/CI pipe (any size or pattern ) including all fitting, heads, shoes, bends and removing from sites complete all as specified and directed.Note : (Measured over all as fixed along the centre line over the fittings and accessories) |
| 31 | S&F 110mm PVC (SWR) pipes single socketed in any length with rubber joints fixed to wall or laid in floors / trenches with & including existing / new MS stack clamps of FI 50 x 3mm complete all as specified and directed. |
| 32 | S&F 75mm PVC (SWR) pipes single socketed in any length with rubber joints fixed to wall or laid in floors / trenches with & including existing / new MS stack clamps of FI 50 x 3mm complete all as specified and directed. |
| 33 | S&F 110mm bore PVC (SWR) bend / shoe of any radius with access door, complete all as specified and directed. |
| 34 | S&F 75mm bore PVC (SWR) bend / shoe of any radius with access door, complete all as specified and directed. |
| 35 | Dismantling wall and ceiling boards (fiber, Gypsum,wooden board, insulation etc.) any thickness, including cover fillets, Suply & Fixing false ceiling with Everest Fibre Cement Designer tile Ivory painted (High Pressure Steam Cured) of 4mm thickness (as per IS:14862) of size 595x595 mm and any one of the design (oceanic, lake & hill, cascade or electra) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 gms, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and 15x32 mm made from 0.30 mm thick sheet, spaced at 1200 mm c/c and cross \\"T\\" of size 15x32 mm made of 0.30 mm sheet, 1200mm long spaced between main \\"T\\" at 600 mm c/c to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size15x32 mm made of 0.30 mm thick sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 15x20 mm made of 0.30 mm thick sheet and laying false ceiling tiles in the grid including , required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI soffit cleats fixed to existing RCC lintel with dash fasteners, GI adjustable rods of 3mm dia with galvanised Butterfly level clips, spaced at 1200 mm c/c along main T, bottom exposed width of 15mm of all T -sections shall be centra black pre-painted with polyester paint, and having a load bearing capacity of 12 kg/sqm, complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 36 | Dismantling wall and ceiling boards (fiber, Gypsum,wooden board, insulation etc.) any thickness, including cover fillets, Suply & Fixing false ceiling with Everest Fibre Cement Designer tile Ivory painted (High Pressure Steam Cured) of 4mm thickness (as per IS:14862) of size 595x595 mm and any one of the design (oceanic, lake & hill, cascade or electra) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 gms, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and 15x32 mm made from 0.30 mm thick sheet, spaced at 1200 mm c/c and cross \\"T\\" of size 15x32 mm made of 0.30 mm sheet, 1200mm long spaced between main \\"T\\" at 600 mm c/c to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size15x32 mm made of 0.30 mm thick sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 15x20 mm made of 0.30 mm thick sheet and laying false ceiling tiles in the grid including , required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI soffit cleats fixed to existing RCC lintel with dash fasteners, GI adjustable rods of 3mm dia with galvanised Butterfly level clips, spaced at 1200 mm c/c along main T, bottom exposed width of 15mm of all T -sections shall be centra black pre-painted with polyester paint, and having a load bearing capacity of 12 kg/sqm, complete all as specified and as directed. Please Enable Macros to View BoQ information |