Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth; for foundation, n exc 10 sqm on plan and n exc 1.5m in depth and getting out any type of soil complete all as specified and directed. |
| 2 | Surface excavation n exc. 30 cm deep and averaging 15cm and getting out in loose/ soft soil complete all as specified and directed |
| 3 | Taking down chowkhat with shutter not exc 1.5 sqm each complete all as specified and directed. |
| 4 | `Ditto~ all as per item No 3 above but exc 1.5 sqm but nexc 4.0 sqm each complete all as specified and directed. |
| 5 | Demolition of PCC of any description and any position not otherwise provided for complete all as specified and directed |
| 6 | Dismantling timber scantlings 40 sq. cm and over in section, in any position in framed works complete all as specified and directed |
| 7 | Dismantling timber scantlings in fillets, rails, posts,rafters,purlins, etc. under 40 sq. cm in section in framed works complete all as specified and directed |
| 8 | Dismantling Asbestos cement / CGI PGI (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed. |
| 9 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed |
| 10 | Demolition of RCC of any description and any position not otherwise provided for complete all as specified and directed |
| 11 | M&L for Cement concrete type D-2 1:4:8 (using 40 mm graded aggregate) as in foundation filling and mass concrete complete all as specified and directed |
| 12 | Demolition of brick masonry built in cm incl quoins arches pillars etc.complete all as specified complete all as specified and directed. |
| 13 | M&L for brick work with Sub class 'B' bricks straight or curved on plan exc 6m mean radius built in cement mortor 1:4.complete all as specified and directed. |
| 14 | M&L for brick work with sub class 'B' bricks using old size bricks, straight or curved on plan to any radius, built in CM 1:4 as in half brick thick wall complete all as specified and directed. |
| 15 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, in any type of soil complete all as specified and directed. |
| 16 | Dismantling posts or strut (wood, steel or R.C.C.) any section, including taking out embedded portion in ground or in cement concrete brick work,masonary etc and making good disturbed ground complete all as specified and directed. |
| 17 | Dismantling of Chain link fencing wire any type complete all as specified and directed. |
| 18 | M&L for RCC (Design mix M-25) in foundations, including, rafts, footings, foundation beams, bases for columns, etc , basement slab, under reamed piles and mass concrete complete all as specified and directed.Note:- Reinforcement shall be measured and paid separately under respective item. |
| 19 | M&L for RCC M-25 design mix as in columns , pillars, piers, posts and struts etc complete all as specified and directed.Note:- Reinforcement shall be measured and paid separately under respective item. |
| 20 | M&L for RCC (Design mix M-25) in beams, cantilevers, bressumers, lintels,chajjas over 1.50 m span complete all as specified and directed. Note:- Reinforcement shall be measured and paid separately under respective item. |
| 21 | M&L for RCC (Design mix M-25) as in roof slabs, CB slab complete all as specified and directed.Note:- Reinforcement shall be measured and paid separately under respective item. |
| 22 | M&L Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed. |
| 23 | Use and waste Formwork to sides of concrete fdn, footings, bases of cols, raft and raft beams, sides and soffits of fdns and plinth beams and similar works vertical or to batter, rough finish surfaces of concrete complete all as specified and directed. |
| 24 | Use and waste Formwork to sides of pillars,posts,struts,piers,cloumns and stanchions rough finish surfaces of concrete complete all as specified and directed. |
| 25 | Use and waste Formwork to sides and soffits of floor or roof beams, lintels,cantilevers etc.fair finish complete all as specified and directed. |
| 26 | Use and waste Formwork to sides and soffits of chajjas etc.fair finish complete all as specified and directed. |
| 27 | Use and waste Formwork to soffits of suspended slabs such as roof slabs, floor slabs,CB slab, landings and similar work, n.exc 200mm thick (Horizontal or slopping) for fair finished surfaces complete all as specified and directed. |
| 28 | Use and waste Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and directed. |
| 29 | M&L mild steel TMT bar 10 mm dia and over, cut to length, bent to shape required incl cranking, bending and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc complete all as specified and directed. |
| 30 | M&L mild steel TMT bar 6 to 8 mm dia, cut to length, bent to shape required incl cranking, bending and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc complete all as specified and directed. |
| 31 | M&L mild steel TMT bar 5 mm dia and over upto and inlcluding 10 mm dia in stirrups,spacers and binders etc complete all as specified and directed. |
| 32 | M&l for PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregate Cement concrete in surface channels and drains complete all as specified and directed. |
| 33 | M&L for Cement concrete 100 mm thick type C- 2, 1:2:4 (40mm graded aggregate) complete all as specified and directed. |
| 34 | S&F Coloured Glazed ceramic tiles in vertical surfaces 350x250mmx7mm /450x350x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile over and including 15mm thick backing coat in CM(1:4) on fair face of brick or concrete surface complete all as specified and directed. |
| 35 | S&F Coloured Non Skid coloured ceramic tiles 7 to 8mm thick (squares/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile over and including 20mm thick screed in CM(1:6) complete all as specified and directed. |
| 36 | M & L for Virified Ceramic tiles single/double charged (light shade)10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile over and including 20 mm thick screed bed in CM 1:4 to recieve tiles complete all as specified and directed. |
| 37 | M & L for Virified Ceramic tiles single/double charged (light shade)10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile over and including 10 mm thick screed bed in CM 1:4 to recieve tiles complete all as specified and directed. |
| 38 | Hacking and roughning surfaces of old concrete floor by picking, sweeping clear and washing down with water to remove dust and brushing neat cement slurry with 3 kg of cement per Sqm complete all as specified and directed. |
| 39 | S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to Fe-410- W(Gde- E-250) quality- B complete all as specified and directed. |
| 40 | S&F mild steel work as wind ties for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed , drilling holes, notching for wires etc, flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting , etc and similar work confirming to FE-290 Gde-E-165 complete all as specified and directed. |
| 41 | M&L for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 42 | M&L for Pre- painted galvalume aluminum zinc coating GI based Plainsteel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 43 | Complete removal of existing treatment of walls and applying coat of wall care putty complete all as specified and directed. |
| 44 | Material & labour for Rendering 15 mm thick CM 1:6 on brick or concrete surfaces finished even & smooth without using extra cement including scaffolding complete all as specified and directed. |
| 45 | Material & labour for Rendering 15 mm thick CM 1:4 on brick or concrete surfaces finished even & smooth without using extra cement including scaffolding complete all as specified and directed. |
| 46 | Dismantling floor , hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles and removing debris and depositing complete all as specified and directed. |
| 47 | Taking down cement or cement lime plaster, any description on brick or stone walls, ceiling etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed. |
| 48 | M&L for PCC (1:2:4) Type B0 using 20mm graded Agg as in Padding/Leveling Course over Roof/Under Floor etc. Complete all as specified and directed. |
| 49 | Complete removal of existing water proofing treatment of any description and in any position including PCC padding any thickness and cleaning, wire brushing, watering & removal of debris outside site n.exc 2.00 Km complete all as specified and directed.Note:- Unit rate quoted shall also include for removal of PVC water storage tank wherever existing carefully and refixing at the same or other position after completion of roof repair work. |
| 50 | M&L water prooofing treatment on roof surface (horizonal & vertical surfaces) in following sequence through manufacturer/authorised apploicator of the manufacturer incl properly cleaning & drying the concrete surfaces complete all as specified and directed |
| 51 | M&L for 10mm thick rendering on roof surfaces /concrete surfaces in CM 1:4 complete mixed with WPC complete all as specified and directed |
| 52 | M & L for laying APP 3mm thick over primer unrolled over the bitumen coated surface polymeric water proofing membrane hyperplus standard wt not less than 3 Kg/Sqm with 100mm overlaps shall be sealed by flame as per manufacturers instructions complete all as specified and directed. |
| 53 | Applyoing two coats of bitumen based aluminum paint incl preparation complete all as specified and directed |
| 54 | Supply only WPC complete all as specified and directed. |
| 55 | S&F in repairs E-boards, ceiling, 4 mm thick with J framed work with main Tee of size 24 x 28.5 mm made out of PGI sheet .3 mm thick double at web and single at flange, flange coverd with powder coated sheet 0.25 mm thick and wall angle 24 x 24 x .45 mm powder coated for ceiling , ceiling boards 60cm x 60cm x 4mm thick , suspended with GI wire 2mm dia and 2m average length with adjustable hanging device complete including plugging in brick/stone walls with steel rawl plug @ 600 mm C/C Ceiling board shall be pressed to the ceiling tee with staple clips at all four sides and incl making good of all disturbed/daimage surface of walls and applying two coat of oil bound distemper complete all as specified and directed. |
| 56 | M&L for 5 mm thick cement plaster in CM 1:3 on internal surfaces of fair faces of brick work or concrete surfaces wall/ceiling with finished surfaces even and smooth with out using extra cement complete all as specified and directed. |
| 57 | M&L for PCC 1:3:6 type C-1 (using 20 mm graded stone agg) as in seismic and other similar bands, coping, bed block or similar work including necessary form work complete all as specified and directed. |
| 58 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. |
| 59 | M & L for applyoing two coats of fire resistant paint over steel, plastered/un plastered, wood surfaces incl preparation complete all as specified and directed. |
| 60 | M&L for prepareation of new/old internal surfaces of wall/ceiling and applying oil emulsion with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. Two or more coats on new/old work.,over a coat of primer incl wall putty complete all as specified and directed. |
| 61 | S & F MS works for fencing post and struts including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting, etc conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 62 | S&F in Framed work as in doors or gates of angle or other section with gusset plates, rails,braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering,running rails and guides) and hanging; also fastening and fixing complete conforming to Fe-410-W (Gde-E-250) quality-A complete all as specified and directed. |
| 63 | M & L for galvanised 2 strand, steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossings with and provision of galvanised mild steel wire staples or steel pins etc complete all as specified and directed. (Each line wire to be measured). |
| 64 | M & L for Granite (of any type) work 16 to 18 mm thick (table rubbed and polished) for wall lining/flooring over 10mm thick in cement mortar (1:4) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. |
| 65 | S&F 10-12 mm thick out door vitrified paver tiles area n. exc 0.36 sqm each as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile over and includin 20mm thick screed in CM(1:6) complete all as specified and directed. |
| 66 | Material and labour for providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with aproved colour, design & attern as in foothpath, parks, lawns, drive ways or light traffic arking etc. of required strenght, thickness & size / shape, made by table vibrating method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding / laying of interlocking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra cement complete all as specified and directed. |
| 67 | M&L for Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed. |
| 68 | M&L for preparation of new or previously untreated surfaces of steel of any description, over 10cm in width or girth and apply two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 69 | M&L for preparation of new or previously untreated steel and iron surfaces of any description n exc 10 cm width or girth when unconnected with other painting or painted in a different tint and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 70 | M&L for preparation of old existing concrete floor surface of any description and in any position by brooming down/ wire brushing & finally cleaning with compressor and to make the surface dust free and providing 5mm thick antistatic EPU flooring including primecoat, screed coat, conductive coat, self leveling top coat including removing old sealant, cleaning and filling joints all ass per manufacturer's instructions complete all as specified and directed. |
| 71 | Material & Labour for providing and fixing stainless steel (Grade 304) railing,Gate,partition,Board frame made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and directed. |
| 72 | M&L for ACM sheets used for sign boards sandwiched construction with a thermoplastic core of 'Low Density Polyethylene' (LDPE) between two thick skins/sheets of aluminium with overall thickness of 4 mm and 3 mm, and aluminium skin thickness of 0.4 - 0.5 mm and 0.25 -0.3 mm respectively on both sides including a coat of fluorocarbon coating over the exposed surface of aluminium to ensure corrosion resistant and weather proof and thus shall conform to relevant ASTM.The mechanical properties of 4 mm and 3 mm ACM and that of its aluminum skin shall conform to the requirement given in Table 6.1,of IRC 67 of 2012 Thickness Shoulder mounted ground signs with a maximum side dimension not exceeding 600 mm shall not be less than 1 .5 mm thick with aluminium and 3 mm thick with aluminium composite material. All other signs shall be at least 2 mm thick with aluminium and 4 mm thick with aluminium composite material incl letter writing were size of letter n. exc 100mm retro-reflective type.PREPERATION :-Surface to be reflectorised shall be effectively prepared to receive the retro-reflective sheeting.The aluminium sheeting shall be de-greased either by acid or hot alkaline etching and' all scale/dust removed to obtain a smooth plain surface before the application of retro-reflective sheeting. If the surface is rough, approved surface primer may be used. After cleaning, metal shall not be handled, except by suitable device or clean canvas gloves, between all cleaning and preparation operation and application of reflective sheeting/primer. There shall be no opportunity for metal to come in contact with grease, oil or other contaminants prior to the application of retro-reflective sheeting. Complete sheets of the material shall be used on the signs except where it is unavoidable. At splices, sheeting with pressure-sensitive adhesives shall be overlapped not less than 5 mm. Where screen printing with transparent colours is proposed, only butt joint shall be used. The material shall cover the sign surface evenly and shall be free from twists, cracks and folds. Cut-outs to produce legends and borders shall be bonded with the sheeting in the manner specified by the manufacturer complete all as specified and directed. |
| 73 | Marking of cautioned and information sign of size exc 30 cm but n.exc 60 cm each by rotro refelecting paint as per direction of Engr-in-charge over prepared surfaces above. Colour scheme and necessary information shall be provided etc complete all as specified and directed. |
| 74 | S&F solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet, reinforced with MS square tube, fixing in same opening complete all as specified and as directed. |
| 75 | S&F for factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top, bottom and side rails, MS frame shall be covered with heat molded plain colour PVC’C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stile and plain colour PVC sheet for top rail lock rail &bottom rail on either side and as gap insert for top rail and bottom rail paneling of plain colour PVC sheet to be fixed in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent cement supplying and fixing in the frame at site complete all as specified and directed. |
| 76 | S&F Butt hinge medium wt. cold rolled MS, size 100 mm complete all as specified and directed. |
| 77 | S&F Extruded aluminium alloy handles fabricated type anodised of size 150mm complete all as specified and directed. |
| 78 | S&F 150 mm size Aluminium anodized barrel Tower bolts of extruded section and fixed complete all as specified and directed. |
| 79 | S&F in repair Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aparture 1.40 mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 80 | S&F S&F in repair 200mm aluminium alloy, anodised, sliding door bolt with hasp, staple bolt type and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed. |
| 81 | S&F Steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and directed. |
| 82 | Taking down steel tubing and connections including cleaning for refixing or removal form site for 15mm bore pipe complete all as specified and directed. |
| 83 | Taking down steel tubing and connections including cleaning for refixing or removal form site for 20mm bore pipe complete all as specified and directed. |
| 84 | Taking down steel tubing and connections including cleaning for refixing or removal form site for 25mm bore pipe complete all as specified and directed. |
| 85 | S&F 15 mm bore tubes medium grade galvanized with all fittings such as sockets, elbows, unions, Tees & short and fixed complete to walls and ceilings or laid in floors of any length complete all as specified and directed. |
| 86 | S&F 20 mm bore tubes medium grade galvanized with all fittings such as sockets, elbows, unions, Tees & short and fixed complete to walls and ceilings or laid in floors of any length complete all as specified and directed. |
| 87 | S&F 25 mm bore tubes medium grade galvanized with all fittings such as sockets, elbows, unions, Tees & short and fixed complete to walls and ceilings or laid in floors of any length complete all as specified and directed. |
| 88 | S & F 500 lit rotational moulded polythylene water storage tanks (cylindrical vertical with closed top) hoistes and fixed in position as in repair complete all as specified and directed. |
| 89 | S & F viterious china wash basin flat back type of size 550 x 400 mm incl cutting and pinning in ends of bracket incl 32 mm chromoum plated waste coupling ,waste pipe ,bracket and incl chromium fancy type pillar tap incl tap oval type complete all as specified and directed. |
| 90 | S & F liquid soap container of PTMT fixed with incl chromium plated brass screw and wooden /plastic cleat complete all as specified and directed. |
| 91 | S&F bib taps, cast copper alloy chromium plated fancy type with crutch or butterfly handle screwed down, screwed for iron pipe or brass ferrule, 15 mm bore complete all as specified and directed. |
| 92 | S&F 15 mm bore angle/ stop cock, cast copper alloy fancy type chromium plated screwed down high pressure with crutch & butterfly handle screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 93 | S&F ball brass valves, high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule. 20 mm bore complete all as specified and directed. |
| 94 | S&F PVC connection 15 mm bore, 450 mm long complete with both ends unions complete all as specified and directed. |
| 95 | S & F 25 mm bore Gun metal glove or gate valve with iron wheel head screwed bith ends for iron pipe complete all as specified and directed. |
| 96 | S & F CP Brass chromium plated tubular towel rail 20 mm dia 60 cm long between flanges complete all as specified and directed. |
| 97 | S & F in repairs sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed. |
| 98 | Supplying, laying and jointing for 150-160mm nominal dia DWC pipes class SN-8 conforing to IS -16098:2013 Part-I stiffness with and incl necessary jointing materials complete all as specified and directed. |
| 99 | M&L for PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in concrete bed to drain pipe including packing under, and hunching against the sides of pipes after they are laid and tested for 150mm dia pipe complete all as specified and directed. |
| 100 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends complete all as specified and directed. |
| 101 | S&F 75 mm dia PVC floor trap with grating incl jointing waste pipe fixed in CM type B1 1:2:4 complete all as specified and directed. |
| 102 | S&F PVC valveless syphonic action type low level flushing cistern, 10 ltrs capacity with inlet, ball valve, float and handle including bracket complete all as specified and directed. |
| 103 | M&L PVC (SWR) pipes, single socketed, in any length, with rubber ring joints fixed on wall/ laid in floors Bore of pipe 75 mm. Including PVC clamp complete all as specified and directed. |
| 104 | M&L PVC (SWR) bends, 75 mm bore any radius complete all as specified and directed |
| 105 | M&L PVC (SWR) branch pieces, double, (double Y/T) equal or unequal. 75 mm bore complete all as specified and directed. |
| 106 | S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 meter long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed. |
| 107 | S&F in vitreous china wash down closet pan pedestral pattern with P or S trap white fixed Including seat cover etc complete all as specified and directed. |
| 108 | S&F vitreous china urinal half stall with CP grating and union for discharge pipe etc complete all as specified and directed. |
| 109 | S&F looking mirror of size selected quality glass fixed with 5mm thick PVC fibre backing and incl chromium plated brass screws and cup washers complete all as specified and directed. |
| 110 | Supply and fixing factory made uPVC white colour Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) upto 1.50m height made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead /double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) comprising of uPVC multichambered frame, with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, complete all as specified and directed by Engineer-in-Charge.Note: For uPVC frame and sash extruded profilesminus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made complete all as specified and directed. |
| 111 | S&F 4 mm thick sheet glass ordinary quality and glazing complete in square nexc 0.50sqm each complete all as specified and directed. |
| 112 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65x125 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/ SS dash fasteners of required dia and length including fastenar of 100 mm long 10 mm dia complete all as specified and directed. |
| 113 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 50 x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/ SS dash fasteners of required dia and length including fastenar of 100 mm long 10 mm dia complete all as specified and directed. |
| 114 | S&F 35mm thick molded WPC factory made 1005 galezed (wire mesh ) door shutter (confirming as per IS: 4020) made from 100% lead free single extruded with 2, 4 or 6 raised panel design on the front side with 10mm deep mould on single side with wood grain texture and back side plain with density not less than 600kg/cum manufactured by an ISO : 9001-2015 certified company. The door should be water proof, termite proof, termite proof, fire retardent and having screw holding capasity complete all as specified and directed. |
| 115 | S & F 30 mm thick molded WPC factory made 1005 solid door shutter (confirming as per IS :4020) made from 100% lead free single extruded with 2, 4 or 6 raised panel design on the front side with 10mm deep mould on single side with wood grain texture and back side plain with density not less than 600 kg / cum manufactured by an ISO : 9001-2015 certified company. The door should be water proof, termite proof, fire retardant and having screw holding capacity complete all as specified and directed. |
| 116 | Fixing only chain link MS galvanised fencing of any size with GI wire including line wires any mesh, size and type to any type of standards, rails, straining bolts, etc including provision of binding wire complete all as specified and directed. |
| 117 | Supply only chain link MS galvanised fencing mesh, size and type of any type of standards, etc complete all as specified and directed. Note: Wt of chain link fencing shall be acertain by BOO. |
| 118 | M&L for Raised pointing to random rubble masonary uncoursed or brought upto course in cement mortar (1:4) complete all as specified and directed |
| 119 | S&F 30mm width Continuous (piano) hinges, mild steel, bright finish or electrogalvanised complete all as specified and directed. |
| 120 | S&F Brass Locks 4 levers, cupboards/wardrobs/drawers, grade I, size 65 mm complete all as specified and directed. |
| 121 | S&F in repair 300mm aluminium alloy, anodised, sliding door bolt with hasp, staple bolt type and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed. |
| 122 | S&F lnsulated PVC board 25mm thick consisting of PVC Insulated Panels having expanded polystyrene (EPS) stuck to 2mm thick plain colour PVC sheet duly fitted into the wall as per specifications and drawing complete all as specified and directed. |
| 123 | Dismantling of boarding any description fixed in any position incl frame with nails complete all as specified and directed. |
| 124 | S&F Solid PVC wall lining consisting of 5 mm thick plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specification and drawing complete all as specified and directed. |
| 125 | S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC frame as per specification and drawing complete all as specified and directed. |
| 126 | Taking down copper/aluminium point wiring(light,fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit(credit for above items should be made as per conitions separately) and making good distrubed surfaces of walls, floors etc. complete all as specified and directed. |
| 127 | M&L for Point wiring complete with 1.5 sqmm single core PVC insulted FRLS cable 1100 volts grade with multistranded copper conductor drawn through and including cover plate and metal flush box as suitable module and including suitable size stove enamelled metallic conduit with all accessories concealed in walls and including provision of 1.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade with multistranded copper conductor cable as earth continuity conductor for one light/fan point controlled by one, one way switch complete all as specified and directed :- |
| 128 | ~ditto~ all as per item No. 127 described here-in-before but with copper conductor cable FRLS 2.5 Sqmm for one 3 pin socket outlet, 15 Amps and including provision of 2.5 Sqmm PVC insulated copper conductor cable as earth continuity conductor on independent board complete all as specified and directed. |
| 129 | S&F flame proof rotary type with with termination box in LM6 16 Amp, single pole 250V complete all as specified and directed. |
| 130 | S&F flame proof switch socket & plug combined LM6 cable 6 cable termination box in LM6,16Amp , 250 V 2P+ Earth complete all as specified and directed. |
| 131 | Supply and fixing LED light fitting 2x16 Watt flame proof ,CMRI, certifierd recommended for gas/vapour group of IIA &IIB , Zone 1 & 2 IP 65 protection with die cast aluminium housing wiith heat resistant toughened glass .with LED tube light fixtures driver,holders, connector etc complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed. |
| 132 | Supply and fixing flame proof cum water proof LED light buk head fitting of 40W/45 W. IP66 protection of cast Aluminum alloy meterail and Heat and Impact resistance toughen 'A' clear glass having Anti corrosive epoxy powder coated finish complete with all accessories pre wired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed. |
| 133 | M&L for Point wiring complete with 1.5 sqmm single core PVC insulted FRLS cable 1100 volts grade with multistranded copper conductor drawn through and including 19 mm size PVC rigid non metallic conduit with all accessories concealed in walls and including provision of 1.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade with multistranded copper conductor cable as earth continuity conductor complete all as specified and directed. |
| 134 | One light/fan /Bell point controlled by one, one way switch complete all as specified and directed. |
| 135 | One switch socket outlet 5 A on same board with other switch complete all as specified and directed. |
| 136 | One switch socket outlet 5 A independent with cable 1.5 sqmm complete all as specified and directed. |
| 137 | ~ditto~ all as per item No.133 described here-in-before but with copper conductor cable FRLS 2.5 Sqmm for one 3 pin socket outlet, 15 Amps and including provision of 2.5 Sqmm PVC insulated copper conductor cable as earth continuity conductor on independent board complete all as specified and directed. |
| 138 | S&F Switch Modular 6A one way, 1 module complete all as specified and directed. |
| 139 | S&F Switch Modular 16A one way, 1 module complete all as specified and directed. |
| 140 | S&F Socket, 6A - 2/3 pin combined 2 module complete all as specified and directed. |
| 141 | S&F Socket 6A/16A - 2/3 pin combined 2 module complete all as specified and directed. |
| 142 | S&F in reapir flame proof exhaust fan , size 12'' and as per relevent IS code complete all as specified and directed. |
| 143 | M&L for earthing complete with galvanized steel earth plate electrode 600x600x6.0mm thick directly burried in the ground (earth pit not less than 2.25M deep below ground level) with top edge of earth plate not less than 1.50M deep below normal ground level, connected to galvanised wire of size 4mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel, 40mm bore GI pipe medium grade including necessary fittings for protection of earthing strip, watering pipe 20mm bore GI medium grade, concrete chamber in PCC (1:4:8) type D-2 using 40 mm grade aggregate, coping shall be in PCC (1:3:6) type C-1 using 20 mm grade aggregate and internal surfaces of concrete chamber shall be given 12mm thick plaster in CM (1:4), funnel with wire gauge of 22 gauge (0.63 mm) 8 mesh per linear incl 50mm thick cover of RCC (1:2:4) type B-1 using 20mm grade stone aggregate reinforced with 8mm MS deformed bar @ 75 mm C/C both ways, char coal dust and common salt all as shown in electrical plate No. 3 of SSR Part-I (2009) including all necessary excavation & earth work and removal of surplus soil to a distance n. exc 50M and providing connection points with MS/ GI bolts & washers as required and connection from earth test point to earth electrode with same GI earth wire alongwith 15 mm GI protection pipe and testing on completion complete all as specified and directed. |
| 144 | S & F air single pointed air termination alumination aluminium rod 12mm dia 300mm long Complete all specified and directed. |
| 145 | Supply and fix aluminium strip 25 mm x3.15 mm complete with saddles and fixing screws for fitting the strip Complete all specified and directed. |
| 146 | Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth strip 32x 6 mm by means of nut, bolts, check nuts and washers of galvanised iron or steel complete all as specified and directed including testing on completion including the material and labour of the following : - (a) Excavation and earth work for drilling hole for electrode in any type of Soil.Complete all specified and directed. (b) reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter.Complete all specified and directed. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 15 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal.Complete all specified and directed. (f) Testing of earthing Complete all specified and directed. |
| 147 | Supply and fix GI Strip 32 x 6mm burried in ground/wall Complete all specified and directed. |
| 148 | Supply and fixing GI tubing medium grade 40mm dia Complete all specified and directed. |
| 149 | Supply and fix PVC rectangular block of size 100 mm x 100 mm and 50mm with 3mm thick plastic laminated sheet cover complete all as specified and as directed |
| 150 | M&L Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3nos, 8mm dia, 25mm long hex.head screw Complete all specified and directed. |
| 151 | Schedule of credit of Amount Rs.80875.00 to be deducted during AOC. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail