| 1 | Taking down old unserviceable/deteriorated batten/PVC conduit point wiring aluminium/ copper from existing place i.e. light, fan, socket or power points complete with any type of unserviceable fittings such as switches, sockets,bell push , ceiling rose, pendants, Holders, etc and making good all disturbed surface to wall, floor etc by means of cement mortar or plaster of Paris and to match / finish new surface as the existing surface either by using same colour distemper, Putti or white / colour wash all as required and directed by Engineer-in-Charge. |
| 2 | M & L for concealed point wiring in wall and floor with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic PVC conduit medium grade ISI marked not less than 20 mm dia with all conduit including accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of suitable thickness with earth dolly and Bakelite laminated sheet ISI marked for fixing of switches / sockets, fan regulators, wall mounting fittings, door bell & bulkhead etc with MS screw and cup washers including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar and for matching / finishing of new surfaces either by means of plaster of peris/ Putti or distemper / colour wash with same existing colour surfaces all as specified and directed by Engineer-in-Charge for the following:- |
| 3 | One light /Fan/Bell point controlled by one switch 6/5 Amp one way single pole. |
| 4 | One 3 pin socket outlet 6/5 Amps controlled by one switch on the same board with other switches. |
| 5 | One 3 pin 6/5 Amp socket outlet controlled by one switch independent board. |
| 6 | One 3 pin 6/5 Amp socket outlet controlled by one switch independent board but below/ side the switch board of light point in same vertical / horzintal plane. |
| 7 | All as per item No 2 here-in-before but for power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 1.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead. |
| 8 | All as per item no 2 here-in -before but for One 3/5 pin 15 Amp socket outlet controlled by one switch indep board but below/ side the switch board of light point in same vertical / Horzintal plane. |
| 9 | M & L for concealed point wiring in wall and floor with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic PVC conduit medium grade ISI marked not less than 20 mm dia with all conduit including accessories/ fittings such as junction boxes, bends, tee, elbow etc alongwith Modular sunken boxes including modular frame / cover plate suitable for mounting switches /sockets etc including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar and for matching / finishing of new surfaces either by means of plaster of peris/ Putti or distemper / colour wash with same existing colour surfaces all as specified and directed by Engineer-in-Charge for the following:- |
| 10 | One light /Fan/Bell point controlled by one switch 6/5 Amp one way single pole. |
| 11 | One 3 pin socket outlet 6/5 Amps controlled by one switch on the same board with other switches. |
| 12 | One 3 pin 6/5 Amp socket outlet controlled by one switch independent board. |
| 13 | One 3 pin 6/5 Amp socket outlet controlled by one switch independent board but below/ side the switch board of light point in same vertical / horzintal plane. |
| 14 | All as per item No 3 here-in-before but for power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 1.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead. |
| 15 | All as per item no 3 here-in -before but for One 3/5 pin 15 Amp socket outlet controlled by one switch indep board but below/ side the switch board of light point in same vertical / Horzintal plane. |
| 16 | M & L for Surface point wiring on wall/ceilng with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic PVC conduit medium grade ISI marked not less than 20 mm dia / PVC Casing & Caping not less then (20 x 12 ) mm including all accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of suitable thickness with earth dolly and Bakelite laminated sheet ISI marked for fixing of switches / sockets, fan regulators, wall mounting fittings, door bell & bulkhead etc with MS screw and cup washers including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar and for matching / finishing of new surfaces either by means of plaster of peris/ Putti or distemper / colour wash with same existing colour surfaces all as specified and directed by Engineer-in-Charge for the following:- |
| 17 | One light /Fan/Bell point controlled by one switch 6/5 Amp one way single pole. |
| 18 | One 3 pin socket outlet 6/5 Amps controlled by one switch on the same board with other switches. |
| 19 | One 3 pin 6/5 Amp socket outlet controlled by one switch independent board. |
| 20 | One 3 pin 6/5 Amp socket outlet controlled by one switch independent board but below/ side the switch board of light point in same vertical / horzintal plane. |
| 21 | All as per item No 4 here-in-before but for power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 1.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead. |
| 22 | All as per item No 4 here-in-before but for One 3/5 pin 15 Amp socket outlet controlled by one switch indep board but below/ side the switch board of light point in same vertical / Horzintal plane. |
| 23 | M & L for Surface point wiring on wall/ceilng with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic PVC conduit medium grade ISI marked not less than 20 mm dia / PVC Casing & Caping not less then (20 x 12 ) mm including all accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of suitable thickness with earth dolly and Bakelite laminated sheet ISI marked for fixing of switches / sockets, fan regulators, wall mounting fittings, door bell & bulkhead etc with MS screw and cup washers including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar and for matching / finishing of new surfaces either by means of plaster of peris/ Putti or distemper / colour wash with same existing colour surfaces all as specified and directed by Engineer-in-Charge for the following:- |
| 24 | One light /Fan/Bell point controlled by one switch 6/5 Amp one way single pole. |
| 25 | One 3 pin socket outlet 6/5 Amps controlled by one switch on the same board with other switches. |
| 26 | One 3 pin 6/5 Amp socket outlet controlled by one switch independent board. |
| 27 | One 3 pin 6/5 Amp socket outlet controlled by one switch independent board but below/ side the switch board of light point in same vertical / horzintal plane. |
| 28 | All as per item No 5 here-in-before but for power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 1.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead. |
| 29 | All as per item No 5 here-in-before but for One 3/5 pin 15 Amp socket outlet controlled by one switch indep board but below/ side the switch board of light point in same vertical / Horzintal plane. |
| 30 | Taking down old unserviceable/deteriorated point wiring aluminium/ copper (excluding PVC conduit/casing & caping & GI/PVC switch box any type and size) from existing place for light light, fan, socket or power points complete with any type of unserviceable fittings such as switches, sockets,bell push , ceiling rose, pendants, Holders sunken box, etc and making good all disturbed surface to wall, floor etc by means of cement mortar or plaster of Paris and to match / finish new surface as the existing surface either by using same colour distemper, Putti or white / colour wash all as required and directed by Engineer-in-Charge. |
| 31 | M&L for drawing the wire in existing conduit steel/PVC casing & caping any type and size ,complete with point wiring with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade along with one single run of same size and type of copper wire as continuous earth wire to common earth dolly in old existing sunken terminal boxes pressed MS/GI/PVC boxes of any type and size for mounting switch, socket etc along with screw and cup washers with all accessories and making good to disturbed surface with cement mortar and matching surface with existing white/colour wash, oil bound or cement base paint etc to match with existing surface complete all as specified and directed and suitable for the following: - |
| 32 | One light /Fan/Bell point controlled by one switch 6/5 Amp one way single pole. |
| 33 | One 3 pin socket outlet 6/5 Amps controlled by one switch on the same board with other switches. |
| 34 | One 3 pin 6/5 Amp socket outlet controlled by one switch independent board. |
| 35 | One 3 pin 6/5 Amp socket outlet controlled by one switch independent board but below/ side the switch board of light point in same vertical / horzintal plane. |
| 36 | All as per item No 7 here-in-before but for power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 1.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead. |
| 37 | All as per item No 7 here-in-before but for One 3/5 pin 15 Amp socket outlet controlled by one switch indep board but below/ side the switch board of light point in same vertical / Horzintal plane. |
| 38 | S & F as in repair modular switch 6A SP one - way 230V white ivory finish complete all as specified |
| 39 | S & F as in repair modular switch 16A SP one - way 230V white ivory finish complete all as specified |
| 40 | S & F as in repair modular socket outlet 2/3 pin 6 amps, multipurpose 2 module 230 Volts, single pole one way suitable for plug tops, complete all as specified. |
| 41 | S & F as in repair modular socket outlet 2/3 pin 16 amps, multipurpose 2 module 230 Volts, single pole one way suitable for plug tops, complete all as specified. |
| 42 | S & F as in repair Modular type stepped electronic fan regulator all as specified & directed |
| 43 | M&L as replacement for modular bell push,single pole,one way,6 Amp suitable for 1 module complete all as specified & directed |
| 44 | S & F as in repair modular switch 6A SP Two- way 230V white ivory finish complete all as specified |
| 45 | M&L as replacement for modular white cover plate with frame and Flush box for 1 to 4 Module complete all as specified & directed |
| 46 | M&L as replacement for modular white cover plate with frame and flush box for 6 to 12 module complete all as specified & directed |
| 47 | Supply & Fixing as replacement medium step type fan regulator 80 Watt, 240 Volt AC, socket size, medium step\\" ISI marked complete all as specified and directed. |
| 48 | S&F as replacement switch piano flush type (ISI marked), single pole, one way 6 Amp, 240 Volts complete all as specified and as directed. |
| 49 | S&F as replacement switch piano flush type (ISI marked), single pole, one way 16/15 Amps, 240 Volts including complete all as specified and as directed. |
| 50 | S&F as replacement socket outlet 3 pin, 6 Amp piano flush type including complete all as specified and as directed. |
| 51 | S&F as replacement socket outlet, 2 in 1, 3/5 pin 6 / 16 Amp, piano flush type complete all as specified and as directed |
| 52 | S&F as replacement bell push 5/6 Amps SP flush type complete all as specified and as directed. |
| 53 | S&F as replacement Ding dong sound door call bell electric AC 240 volt, 50 Hz ding dong type including taking down unserviceable complete all as specified and as directed. |
| 54 | S&F as replacement Angle lamp /batten holder fixed on wall /ceiling all as approved and directed by Engineer-in-charge. |
| 55 | S&F as replacement ceiling rose, surface bakelite, 65mm x 50mm, two to three terminals complete all as specified and as directed. |
| 56 | Supply and fixing as in repair Metal clad socket outlet with single pole and nuetral enclosure with two pin and earth plug socket complete with one single pole MCB 20 Amps complete all as specified and directed by EIC. |
| 57 | S&F Ceiling Fan AC single phase 230 volts for size 1200 mm sweep, including fixing arrangement including nut, bolts, washer etc, with necessary eletric connection with suitable copper wire from ceiling rose complete all as spd and directed. inluding removing and dismentaling of old UNSV fan any type and size and deposited it in MES Store yard or as directed by EIC. |
| 58 | M & L as in repair for Sub main wiring complete with two single core 2.5 sqmm,1100 volts grade, PVC insulated, stranded copper conductor FRLS cable with continuous copper earth conductor of 2.5 sqmm in and including PVC conduit/Casing caping incl accessories complete all as specified. (Note:- (i) Making good of disturbed surfaces will be done by contractor without any claims. (ii) 3 runs of 2.5 Sqmm conductor and one run of PVC conduit/casing caping shall be measured as one unit length.) |
| 59 | M & L as in repair for Sub main wiring complete with two single core 4 sqmm,1100 volts grade, PVC insulated, stranded copper conductor FRLS cable with continuous copper earth conductor of 4 sqmm in and including PVC conduit /casing caping incl accessories complete all as specified. (Note:- (i) Making good of disturbed surfaces will be done by contractor without any claims. (ii) 3 runs of 4 Sqmm conductor and one run of PVC conduit /casing caping shall be measured as one unit length.) |
| 60 | M & L as in repair for Sub main wiring complete with Two single core 6 sqmm and one core of 6 sqmm earth wire,1100volts FRLS grade, PVC insulated, stranded copper conductor cable with continuous copper earth conductor in and including PVC Conduit /casing caping including accessaries complete. (Note:- Making good of disturbed surfaces will be done by contractor without any claims.(ii) 3 runs of 6 Sqmm conductor and one run of PVC conduig/casing caping shall be measured as one unit length.) |
| 61 | supply and fixing as replacement of MCCB 63 Amps TP/FP16 KA with fixed thermal magnetic release frame F2 optim 1.0 , 4pole all as specified and directed. |
| 62 | Supply and fix as in replacement of 3 Pin Plug Top 16A, White/Black 240V|3 Pin Top complete all as spd and directed. |
| 63 | M & L as in repair for Sub main wiring complete with four single core 10 sqmm and one core of 10 sqmm earth wire,1100volts FRLS grade, PVC insulated, stranded copper conductor cable with continuous copper earth conductor in and including PVC Conduit/casing caping including accessaries complete. (Note:- Making good of disturbed surfaces will be done by contractor without any claims.(ii) 5 runs of 10 Sqmm conductor and one run of PVC Conduit/casing caping shall be measured as one unit length.) |
| 64 | Supplied and fixing in replacement PVC conduit by Non Metallic Rigid PVC conduit, ISI Marked, medium grade of size 25 mm dia including all fittings like bends, elbow reducer, junction boxes, tee bell mouth all fixing accessories such as coupler lock, nuts, saddles pipe hooks etc complete including Cutting & Chasing required on brick wall not exceeding 10 CM girth for concealed conduit wiring and making good to disturbed surface with cement mortar 1:3 and distemper / colour wash etc to match with existing surfaces including facing / finishing complete all as specified and directed. |
| 65 | Supply and fix as in repair LED Tube light fittings 18/20 W White/warm white Surface and wall mounted LED batten, 6500K colour temparature. Soft & uniform light, instant start electronic driver efficiency >85%, complete including all accessories internally pre-wired in and including connecting up with twisted flexible copper conductor cable of suitable size from ceiling rose to connector complete all as specified and directed. |
| 66 | S & F in replacement of LED light fittings 2'x2' of capacity 35/36 watts White/warm white LED surface/reccess environmental friendly, new genereation, aesthetically designed, ultra modern recess mounting luminaire with high brightness glare free soft illumination, white powder coated housing with LEDs, seamless front frame with flat white acrylic cover, 230 volts with all accessories internally pre wired and necessary mounting arrangements complete all as specified. . |
| 67 | S & F in replacement of surface/ceiling mounted with in-built driver, power factor > .9 operating voltage 230 V, round/square/rectangular shape 6 to 9 LED downlighter of white/neutral white/ warm white color temperature , of size as per site requirement etc along with 3 core prewired and all accessories complete all as specified and directed. |
| 68 | S & F in replacement of surface/ceiling mounted with in-built driver, power factor > .9 operating voltage 230 V, round/square/rectangular shape 12 to 15 LED downlighter of white/neutral white/ warm white color temperature , of size as per site requirement etc along with 3 core prewired and all accessories complete all as specified and directed. |
| 69 | S & F in replacement of surface/ceiling mounted with in-built driver, power factor > .9 operating voltage 230 V, round/square/rectangular shape 18 to 20 LED downlighter of white/neutral white/ warm white color temperature , of size as per site requirement etc along with 3 core prewired and all accessories complete all as specified and directed. |
| 70 | S&F as in repair LED street/ Building light with pressure die-cast housing along with prismatic polycarbonate diffuser and LEDs with secondary optics and IP 65 protection 30 watt complete with all accessories and wall mounting bracket of suitable size including clamps, nut bolts etc. prewired 3 core flexible wire complete all as specified as directed. |
| 71 | S&F in replacement of LED light fitting surface and wall mounted LED batten with PVC housing & integrated electronic sensor complete in all respect of 10W cap complete all as specified and as directed |
| 72 | S&F in replacement of LED bulk head light fitting surface and wall mounted LED batten with complete in all respect and as per sample approved by EIC of 10W cap complete all as specified and as directed |
| 73 | Supply & fix as in repair Electric Storage water heater of capacity 25 Ltr , 230 V energy efficient complete all as specified and directed by Engineer-in-charge. |
| 74 | S&F Exhaust fan AC single phase 230 volts for size 300 mm sweep, including fixing arrangement including nut, bolts, washer etc, with necessary eletric connection with suitable copper wire from ceiling rose complete all as spd and directed inluding removing and dismentaling of old UNSV ex fan any type and size and deposited it in MES Store yard or as directed by EIC. |
| 75 | S&F Exhaust fan AC single phase 230 volts for size 200 mm sweep Plastic body along with louvers, including fixing arrangement including nut, bolts, washer etc, with necessary eletric connection with suitable copper wire from ceiling rose complete all as spd and directed. inluding removing and dismentaling of old UNSV ex fan any type and size and deposited it in MES Store yard or as directed by EIC. |
| 76 | S&F Exhaust fan AC single phase 230 volts for size 250 mm sweep plastic body along with louvers, including fixing arrangement including nut, bolts, washer etc, with necessary eletric connection with suitable copper wire from ceiling rose complete all as spd and directed. inluding removing and dismentaling of old UNSV ex fan any type and size and deposited it in MES Store yard or as directed by EIC. |
| 77 | S&F as in repair vertical 4 way TPN double door, recess mounted/wall mounted alongwith along with MCCB 100Amp 01 Nos , MCB SP 16Nos of 63 Amp, MCCB & MCB is pre-fitted at factory & including price of MCCB & MCB, all as specified. (Note : Empty space shall be covered by blanking plate and connect with lugs without any extra cost ) |
| 78 | S&F as in repair MCB TPN DB 4 way double door with 200 amps rated busbar 415 V, all as specified. |
| 79 | Supply & Fixing in replacement of DB by SPN Distribution Box, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 8 way complete all as specified and directed. |
| 80 | Supply & Fixing in replacement of DB by SPN Distribution Box, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 12 way complete all as specified and directed. |
| 81 | Supply & Fixing in replacement of DB by SPN Distribution Box, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 4 way complete all as specified and directed. |
| 82 | Supply & Fixing in replacement of DB by SPN Distribution Box, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 2 way complete all as specified and directed. |
| 83 | supply and fixing as replacement of MCCB 100 Amps TP/FP16 KA with fixed thermal magnetic release frame F2 optim 1.0 , 4pole all as specified and directed. |
| 84 | Supply & Fixing as replacement MCB SPN, 5 to 40 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,complete all as specified and directed. |
| 85 | Supply & Fixing as replacement MCB SP, 06 to 40 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,\\"ISI marked complete all as specified and directed. |
| 86 | Supply and fixing as in replacement of MCB TPN, 63 Amps 415 volts, AC , 10 KA breaking capacity 'C' Series,\\"ISI marked and complete all as specified and directed. |
| 87 | Supply and fixing as in replacement of MCB Tripple pole of rated capacity 40/63 amps, 415 volts breaking capacity 10 KA, C-curve complete all as specified. |
| 88 | M & L as in replacement for earthing with galvanised steel earth plate electrode 60cmx60cmx 6.3 mm buried directly in ground earth pit not less than 2.25 m deep below normal ground level, with top edge of the plate vertically to depth of not less than 1.5 m below ground level connected to and incl GI wire 4 mm dia and GI pipe 15 mm dia light grade for protection to the extent of 7.5 m as earthing lead by means of GI bolts and nuts etc connecting to equipment with provn of charcoal and salt etc all as per electrical plate No 3 of SSR Pt-I incl RCC cover and MS angle iron frame, watering arrangement with GI pipe 20 mm dia and MS funnel, concrete pit incl excavation and earth work in any type of soil and testing on completion etc complete (NOTE:-GI earth wire and protection pipe beyond 7.5m will be measured and paid separately) |
| 89 | S&F in replacement of old sketch fitting/any type by decorative wall mounted LED lamp (white/ warm) complete all as specified and directed as per sample approved |
| 90 | S&F in replacement of decorative wall mounted LED lamp (white/ warm) for main gate complete all as specified and directed as per sample approved |
| 91 | Note for all above :-(a) Contractor/his rep/his electrician will attend the complaint cell perodically all as directed by EIC, any ladder /eqpt/ necessary electrical tools to check and troubleshoot electrical complaints for various location of AFMC is all inclusive .(b) Complaint related to no lights, replacing of switches, sockets, , replacing burnt MCB, short circuit, voltage fluctuation due to internal wiring, repair to faulty earthing etc will be attended withing 8 hour of raising complaint.(c) The complaint can be registered Telephonic/complaint slip, WhatsApp and any other mode of communication. Please Enable Macros to View BoQ information |