| 1 | Demolition of brickwork or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc., but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified & directed. |
| 2 | Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified & directed. |
| 3 | Demolition of cement concrete (unreinforced) Roof , Floors (other than Ground floors), Beams, staircase,landing,chajjas and similar suspended work complete all as specified & directed. |
| 4 | Demolition of cement concrete (Re-inforced) of any description and in any position not otherwise specifically provided for complete all as specified & directed. |
| 5 | M & L for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc including brushing with neat cement slurry with 3.0 Kg of cement per Sqm complete all as specified & directed. |
| 6 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), rubbish off the debris out of MOD premises complete all as specified and directed |
| 7 | Taking down cement plaster/wall tiles including backing etc from brick/stone walls / concrete surfaces including raking out joints, hacking for key , scrubbing down with water etc complete all as specified and directed |
| 8 | Taking down chowkats or frames including shutters (without taking off shutters from the frame) not exc. 1.5 Sqm each, complete all as specified & directed. |
| 9 | Taking down chowkats or frames including shutters (without taking off shutters from the frame) exc. 1.5 Sqm but n exc 4.0 sqm each, complete all as specified & directed. |
| 10 | Taking down shutters of any description exc. 1 sqm and not exc. 2 Sqm each, complete all as specified & directed. |
| 11 | Taking down, easing and adjusting shutters of any description, exceeding. 1.00 Sqm and not exceeding 2.00 Sqm each and re-fixing in the same or other opening complete all as specified and directed. |
| 12 | Taking up or down steel tubing of 20mm bore pipe and connection laid in trenches or floors or fixed to walls and including cleaning for refixing or removal to store with all fittings, complete all as specified and directed. |
| 13 | Taking up or down steel tubing of 15mm bore pipe and connection laid in trenches or floors or fixed to walls and including cleaning for refixing or removal to store with all fittings, complete all as specified and directed. |
| 14 | Dismantling of plain or corrugated AC sheeting, any gauge, thickness, including ridge etc as in roof covering complete all as specified & directed. |
| 15 | Taking down eaves gutters and rainwater pipes (any size or pattern) , including all fitting ,head ,shoes ,bend, swan-nacks etc., including cleaning or refixing or removal to store complete all as specified and directed. |
| 16 | M&L for rendering or plastering work 10mm thick in CM 1:3 with WPC @ 0.200 ltr in 50 Kg of cement in fascia or edging of chajjas, ceiling and roof proIections etc, including taking out peeled off plaster / concrete incl roughening old concrete surface and making the line in true shape and finishing the surface (without using extra cement) complete all as specified & directed. |
| 17 | M&L 15 mm thick rendering in (cement mortar 1:4) mixing with WPC @ 200 ml/ bag of cement on brick or concrete surfaces and finished even and smooth without using extra cement complete all as specified & directed. |
| 18 | M&L 15mm thick cement plaster on faces of brick work or concrete surfaces in cement mortar (1:6) finished even and fair without using extra cement complete all as specified & directed. |
| 19 | M&L for Brickwork with Fly Ash Bricks (old size), straight or curved on plan exceeding 6 metre mean radius built in cement sand mortar 1:6 complete all as specified. |
| 20 | Material and labour for complete removal of existing treatment on wall and ceiling roofs etc by scraping with mechanical sander having mechanical vaccum mechanism, sanding pad of grit 80 to make free from dust ,paint by skilled labour and applying two coats of oil emulsion distemper with fully automatic airless spray machine paint application with flow speed minimum one ltr per minute having a pressure 3300 PSI over a new or old untreated plaster surface finish with one coat of primer over 1 mm thick wall care putty complete all as specified. |
| 21 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm incl complete removal of existing treatment surfaces incl 1 mm thick wall putty over old or new plastered surface to prepare the surface even and smooth complete all as specified and directed. |
| 22 | M&L for light shade vitrified tiles 8 to 9 mm thick (Square or rectangular) polished, area of each tile not exceeding 0.36 sqm in floor etc set and Iointed (Ioint free) in neat cement slurry and pointed in coloured cement. including 15mm thick screed bed in CM (1:6) and finished rough etc complete all as specified and as directed. |
| 23 | M&L for light shade vitrified tiles 8 to 9 mm thick (Square or rectangular) polished, area of each tile not exceeding 0.36 sqm in skirting etc set and Iointed (Ioint free) in neat cement slurry and pointed in coloured cement. including 10mm thick rendering in CM (1:4) and finished rough etc complete all as specified and as directed. |
| 24 | M&L for non skid ceramic coloured tiles 7 to 8 mm thick (Square/rectangular) in floor etc area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, set and Iointed in neat cement slurry and pointed in white or coloured cement to match over and incl 15mm thk screed bed in CM 1:6 all as spd and directed. |
| 25 | M&L for glazed ceramic coloured tiles of size 450mmx300mm, thickness 7mm as in vertical surfaces such as skirting, dado, wall etc., set and Iointed in neat cement slurry and pointed with coloured cement to match over and including 10mm thick rendering in cement mortar 1:4 complete all as specified & directed. |
| 26 | M&L for Machine cut kota stone slab flooring 18 to 20 mm thick over cement screed base laid and Iointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete Iointed in neat cement slurry and pointed in white or coloured cement to match over and incl rendering 10mm thick in CM (1:4) on brick or concrete surface complete all as spd & directed. |
| 27 | M&L for machine cut Kota stone slab not less than 16mm thick as in riser of steps, skirting, dado and pillar laid over & including 10 mm thick screed base in CM 1:4 and Iointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, grinding and polishing to yield mirror finish with machine, complete all as specified. |
| 28 | M&L for Granite (of any type ) work 20mm thick (table rubbed and polished) in cooking plateform, window cill, Iambs, steps and like in CM 1:4 over and 15 mm thick screed in Cm 1:6 incl pointing in white cement (1:2) using marble dust with admixture of pigment to match with Granite shade including rounding the exposed edege full round complete all as specified and as directed. |
| 29 | M&L Cement concrete type C-1, 1:3:6 (using 20mm graded aggregate) as in plinth protection and paving 75mm thick laid in slope finished even and fair incl making Ioints at every 2.5 m and at corner filled with bitumen 85/25 and sand in ratio 1:2 by weight and complete all as specified |
| 30 | Taking down existing roof treatment of any description incl mud phuksha or PCC padding if any (any no of layers) including removal to debries in low laying area exc 1.00 KM but n exc 2.00 KM complete all as directed. |
| 31 | M&L for 25 mm thick (avg thickness) cement concrete 1:1.5:3 type B-0 (using 12.50 mm graded stone aggregate) with WPC and GI wire netting of size 0.71 mm dia of wiore and avg width of aperature 25 mm of as in floor by maintaining required gradient / unddulation, finished even and fair as in roof padding including preparation of surface and mix with water prrofing compound and finish even and fair without using extra cement, complete all as spd and directed. |
| 32 | The surface shall be rendered clean prior to application of smart care damp proof ultra. Wire brushing shall be done so as to get rid of any kind of loose material and debris. The surface shall be free from oil deposits laitance etc. Supplying & treating the cracks up to 3 mm width with a single pack fibre glass reinforced crack filling compound smart care crack seal or equivalent etc complete as per manufacture specification. |
| 33 | M&L for 20mm thick cement plaster in cement mortar 1:4 on concrete surface finished even and smooth using WPC liquid of make mentioned in Annexure-I to particular specification as per manufacturer instruction @ 0.200 ltr in 50 Kg of cement complete all as specified and directed. |
| 34 | Material and labour for preparation of surfaces and apply first of coat Fiber reinforced elastomeric liquid water proofing membrane formulated with PU hybid polymers and reinforcing acrylic fibers with Sun Reflective Index (SRI) of 100-110,having minimum elongation of 350%,tensile strength of 2.9 Mpa and shall have cracks bridging ability upto 2.5 mm and shall resist 10 bars of hydrostatic pressure & reduce surface temperature upto 10 degree Celsius with 33% dilution of priming coat.Laying of Fibre mesh of 0.3 mm thickness weavo in leno pattern having 45 gsm /sqm and pasting it properly with overlap of 50 mm and allow it dry . Apply scond of undiluted coat @ 0.45 ltr /sqm .Apply third and final coat undiluted @0.45 ltr/sqm complete application to be done by the manufacture or authorised applicator complete all as directed by Engr-in -Charge |
| 35 | M&L for Providing precast cement concrete 1:2:4, type B1 (20 mm graded aggregate) set in CM 1:6, as in cover slabs for wash basin plateform etc with plain fair faces casted in angle iron frame(Angle iron frame measured and paid separetaly) complete all as specified and directed |
| 36 | M&L MS TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking,bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia all as specified. |
| 37 | Supply & fixed 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls with suitable clamp complete all as specified and directed. |
| 38 | S&F PVC (SWR) bend with ovel accessed door any radius 110mm dia bore complete all as specified and directed. |
| 39 | M&L PVC (SWR) floor trap, dia of outlet in 75 mm, plain excluding grating, but including jointing with solvent cement fixed in repair complete all as specified and directed. |
| 40 | M&L PVC (SWR) floor trap, dia of outlet in 110 mm, plain excluding grating, but including jointing with solvent cement fixed in repair complete all as specified and directed. |
| 41 | Supply & fixed, 110 mm bore PVC (SWR) branch piece , with or without excess door, single (Single Y) equal or unequal.with excess door complete all as specified and directed. |
| 42 | Supply & fixed, 110 mm bore PVC (SWR) branch piece, with excess door, double (double Y) equal or unequal, with or without excess door complete all as specified and directed. |
| 43 | Supply & fixed, 110 mm bore PVC (SWR) junction single, (Single T) equal or unequal,with excess door complete all as specified and directed. |
| 44 | Supply & fixed, 110 mm bore PVC (SWR) junction double, (double T), equal or unequal, with excess door complete all as specified and directed. |
| 45 | Supply & fixed in repair, 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints , laid in trenches or in floor complete all as specified and directed. |
| 46 | Supply & fixed in repair, 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches or in floor complete all as specified and directed. |
| 47 | Supply & fixed in repair, 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls with suitable clamp complete all as specified and directed. |
| 48 | Supply & fixed , 75 mm bore PVC (SWR) bends any radius, with or without excess door complete all as specified and directed. |
| 49 | Supply & fixed, 75 mm bore PVC (SWR) branch piece, single (Single Y) equal or unequal ,with excess door complete all as specified and directed. |
| 50 | Supply & fixed, 75 mm bore PVC (SWR) branch piece, double (double Y) equal or unequal.with excess door complete all as specified and directed. |
| 51 | Supply & fixed, 75 mm bore PVC (SWR) junction single, (Single T) ,with excess door, equal or unequal complete all as specified and directed. |
| 52 | Supply & fixed, 75 mm PVC (SWR) junction double, (double T), with excess door, equal or unequal complete all as specified and directed. |
| 53 | Supply & fixed, 75 mm bore PVC (SWR) vent cowl complete all as specified and directed. |
| 54 | S&F for GI pipe 32 mm dia light grade in short length as spout pipe in sunken floor slab laid in slope to brick wall with PCC 1: 2:4 TYPE B -1 complete all as specified and directed. |
| 55 | M & L 15 mm thick plaster in CM 1:4 with intergral water proofing compound and applying 75 mm thick padding and junction coved filling of PCC M-20 Nominal Mix (1:1.5:3) of 12.50mm Agg on the junction of floor and wall the surface shall than he cured and allowed to dry. Apply Epoxy Resins Coating, polymer Modified Cementation coating like brush bond of frsroc,pedilite and bostic as per manufactures instruction both on floor as well as on wall complete all as specified and directed by Engr in Charge |
| 56 | Supply only liquid water proofing compound complete all as specified and directed. |
| 57 | M&L for Cement concrete 1:5:10 type D-2 (using 40mm graded crushed stone aggregate) as in mass filling in sunken slab of toilets, complete all as specified. |
| 58 | Supply and fixing factory made uPVC white colour fixed glazed window/ventilator made of (small series) frame 47 x 50 mm mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area upto 0.75 sqm.) comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge.Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made on this account. Please Enable Macros to View BoQ information |
| 59 | Supply and fixing factory made uPVC white colour fixed glazed window/ventilator made of (small series) frame 47 x 50 mm mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area upto 0.75 sqm.) comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge.Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made on this account. Please Enable Macros to View BoQ information |