Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | SCH 'A PART-I: BUILDING AND STRUCTURESNote: This schedule is pre-priced by MES and the rate indicated as under Col 5 signifies this fact only |
| 2 | Total amount of Sch ‘A’ Part I (Building & Structures) |
| 3 | Total amount of Sch 'A' Part-II (Site Clearance, Excavation and Earthwork) |
| 4 | Total amount of Sch ‘A’ Part III (Internal Water supply) |
| 5 | Total amount of Sch ‘A’ Part IV (Internal Electric Supply) |
| 6 | Total amount of Sch ‘A’ Part V (Road, Path and Culverts) |
| 7 | Total amount of Sch ‘A’ Part VI (Area Drainage) |
| 8 | Total amount of Sch ‘A’ Part VII (Sewage Disposal) |
| 9 | Total amount of Sch ‘A’ Part VIII (External Water Supply) |
| 10 | Total amount of Sch 'A' Part-IX (External Electric Supply) |
| 11 | Total amount of Sch 'A' Part-X (Chain Link Fencing With Gate) |
| 12 | Total amount of Sch 'A' Part-XI (Lightening Protection) |
| 13 | Total amount of Sch 'A' Part-XII (Fire Fighting System) |
| 14 | Total amount of Sch 'A' Part-XIII (Air Conditioning System) |
| 15 | Total amount of Sch 'A' Part-XIV (Water Cooler) |
| 16 | SCHEDULE 'A' PART-XV (MISC B/R AND E/M WORKS)Note: This schedule is not pre-priced by MES and the rate indicated as \\"Rs 0.00\\" under Col 6 signifies this fact only. |
| 17 | Internal Water Supply |
| 18 | S & F 15 mm bore Push cock for urinal for iron pipe and fixed.( PRS-CHR-073) ( 1.5 LPM), complete all as specified and directed. |
| 19 | Supply & Fixing Health faucet (ABS Body) mild steel chromium plated suitable 15 mm dia pipe with 1.25 meter long flexible tube and ABS wall hook with including making connections and fixed in position complete in all respect as specified ) with 1 mtr, flexible pipe 15 mm bore ( braided tube) & hook,complete all as specified & as directed. |
| 20 | S&F Two way bib cock chromium plated with wall flange quarter turn (Low-flow) 16 mm dia. Make - Jaquar Model No KUP-35041PMGE (1.3 LPM) in Crab Tree/Kohler brand complete all as specified and directed by Engineer-in-Charge |
| 21 | Supply & Fixing Pillar taps/cock cast copper alloy with capstan head,chromium plated ,fancy type screwed down high pressure with or without lettered \\"Hot or Cold\\",complete all as specified & as directed for 15 mm bore dia of pipe.(Jaquar Model No. KUP-35001 PMG ( 2.5 LPM) ) |
| 22 | Internal Electric Supply |
| 23 | Supply, installation, testing and commissioning of DALI dimmable recess mounted accent light in fixed type with non-integral fixed output driver having COB type LED, 36° beam angle of light source, luminous flux ≥ 4000 lm, rated luminous efficacy ≥ 100 lm/W, power consumption ≤ 42 W, power consumption tolerance ±10%, initial corrected colour temperature (CCT) 4000/6500K, colour rendering index (CRI) ≥ 80, power factor (fraction) ≥ 0.9, median useful life L70B50 @ Ta = 45 °C ≥ 40000 hrs, surge protection level ≥ 4 kV with die cast aluminium housing and polycarbonate optical cover / lens material, IP20 & IK02 protection, EMI / EMC (B1) compliant, and suitable for 140-270 V input voltage, 50 Hz line frequency, ambient temperature range 0 to 45 °C, class B serviceability, ceiling cutout dia. ≤ 8\\" (200 mm) and fixture height ≤ 75 mm along with all necessary accessories complete all as specified and directed by the engineer-in-charge.Make: Signify RS261B LED40S/840 PSD MB WH PA183 or Techno-commercial Equivalent model of iGuzzini, Trilux or ENDO LightingNOTES:[i] The contractor shall furnish an LM80 report issued by the OEM and LM79 report from an NABL accredited laboratory.[ii] The standard warranty of the light fitting shall be of 5 years. |
| 24 | S & F low height recess mounted downlight in circular form-factor with non-integral fixed output driver having LED light source engine, 120° luminaire light beam spread, luminous flux ≥ 2000 lm, rated luminous efficacy ≥ 110 lm/W, power consumption ≤ 18W, power consumption tolerance ±10%, initial correlated colour temperature (CCT) 6500K, colour rendering index (CRI) ≥ 80, SDCM < 5, THD(i) < 10%, Power Factor ≥ 0.95, median useful life L70B50 @ Ta = 45 °C ≥ 50000 hrs, surge protection level ≥ 2.5kV, etc. with pressure die-cast aluminium housing, polycarbonate diffuser, steel clip (spring), IP20 & IK02 protection, EMI/EMC (B1) compliant, and suitable for 160- 270V input voltage, 50 Hz line frequency, ambient temperature range 0 to 45 °C, class B serviceability, ceiling cutout dia. ≤ 6\\" (150mm) and fixture height ≤ 40mm along with all necessary accessories complete all as specified and directed by the engineer-in-charge.Make: Signify DN296B LED20S-6500 PSU WH or Techno-commercial Equivalent model of iGuzzini, Trilux or ENDO LightingNOTES:[i] The contractor shall furnish an LM80 report issued by the OEM and LM79 report from an NABL accredited laboratory.[ii] The standard warranty of the light fitting shall be of 5 years. |
| 25 | S & F low height recess mounted downlight in circular form-factor with non-integral fixed output driver having LED light source engine, 120° luminaire light beam spread, luminous flux ≥ 1500 lm, rated luminous efficacy ≥ 110 lm/W, power consumption ≤ 13.5W, power consumption tolerance ±10%, initial correlated colour temperature (CCT) 6500K, colour rendering index (CRI) ≥ 80, SDCM < 5, THD(i) < 10%, Power Factor ≥ 0.95, median useful life L70B50 @ Ta = 45 °C ≥ 50000 hrs, surge protection level ≥ 2.5kV, etc. with pressure die-cast aluminium housing, polycarbonate diffuser, steel clip (spring), IP20 & IK02 protection, EMI/EMC (B1) compliant, and suitable for 160- 270V input voltage, 50 Hz line frequency, ambient temperature range 0 to 45 °C, class B serviceability, ceiling cutout dia. ≤ 6\\" (150 mm) and fixture height ≤ 40mm along with all necessary accessories complete all as specified and directed by the engineer-in-charge.Make: Signify DN296B LED15S-6500 PSU WH or Techno-commercial Equivalent model of iGuzzini, Trilux or ENDO LightingNOTES:[i] The contractor shall furnish an LM80 report issued by the OEM and LM79 report from an NABL accredited laboratory.[ii] The standard warranty of the light fitting shall be of 5 years. |
| 26 | S & F surface mounted, dust penetration protected, jet-proof circular downlight with high-gloss mirror optic, reflector type optical cover, integral fixed output driver having LED light source engine, 60° luminaire light beam spread, luminous flux ≥ 3800 lm, rated luminous efficacy ≥ 105 lm/W, power consumption ≤ 36W, power consumption tolerance ±10%, initial correlated colour temperature (CCT) 6500K, colour rendering index (CRI) ≥ 80, initial chromaticity (0.31, 0.32) SDCM < 5, THD(i) < 10%, Power Factor ≥ 0.90, driver failure rate ≤ 1% at 5000 h, median useful life L70B50 @ Ta = 45°C ≥ 50000hrs, surge protection level ≥ 2.5 kV, etc. with die-cast aluminium housing, aluminium reflector and optic material, IP65 & IK02 protection, IEC Safety Class I, and suitable for 220- 240V input voltage, 50 Hz line frequency, ambient temperature range 0 to 45 °C, overall fixture diameter ≤ 200mm and fixture height ≤ 240mm along with all necessary accessories complete all as specified and directed by the engineer-in-charge.Make: Signify SM294C LED40/865 PSU WP WH or Techno-commercial Equivalent model of iGuzzini, Trilux or ENDO LightingNOTES:[i] The contractor shall furnish an LM80 report issued by the OEM and LM79 report from an NABL accredited laboratory.[ii] The standard warranty of the light fitting shall be of 5 years. |
| 27 | S & F surface mounted circular downlight with integral fixed output driver having LED light source engine, 120° luminaire light beam spread, luminous flux ≥ 2000 lm, rated luminous efficacy ≥ 110 lm/W, power consumption ≤ 18W, power consumption tolerance ±10%, initial correlated colour temperature (CCT) 6500K, colour rendering index (CRI) ≥ 80, SDCM < 5, THD(i) < 10%, Power Factor ≥ 0.90, median useful life L70B50 @ Ta = 45 °C ≥ 30000 hrs, surge protection level ≥ 2.5 kV, etc. with pressure die-cast aluminium housing, polycarbonate diffuser, steel clip (spring), IP20 & IK02 protection, IEC Safety Class I, and suitable for 220- 240V input voltage, 50Hz line frequency, ambient temperature range 0 to 45°C and fixture height ≤ 60mm along with all necessary accessories complete all as specified and directed by the engineer-in-charge.Make: Signify SM296C LED20S-6500 PSU WH or Techno-commercial Equivalent model of iGuzzini, Trilux or ENDO Lighting[i] The contractor shall furnish an LM80 report issued by the OEM and LM79 report from an NABL accredited laboratory.[ii] The standard warranty of the light fitting shall be of 5 years. |
| 28 | S & F surface mounted circular downlight with integral fixed output driver having LED light source engine, 120° luminaire light beam spread, luminous flux ≥ 1500 lm, rated luminous efficacy ≥ 110 lm/W, power consumption ≤ 13.5W, power consumption tolerance ±10%, initial correlated colour temperature (CCT) 6500K, colour rendering index (CRI) ≥ 80, SDCM < 5, THD(i) < 10%, Power Factor ≥ 0.90, median useful life L70B50 @ Ta = 45 °C ≥ 30000 hrs, surge protection level ≥ 2.5kV, etc. with pressure die-cast aluminium housing, polycarbonate diffuser, steel clip (spring), IP20 & IK02 protection, IEC Safety Class I, and suitable for 220- 240V input voltage, 50Hz line frequency, ambient temperature range 0 to 45 °C and fixture height ≤ 60mm along with all necessary accessories complete all as specified and directed by the engineer-in-charge.Make: Signify SM296C LED15S-6500 PSU WH or Techno-commercial Equivalent model of iGuzzini, Trilux or ENDO LightingNOTES:[i] The contractor shall furnish an LM80 report issued by the OEM and LM79 report from an NABL accredited laboratory.[ii] The standard warranty of the light fitting shall be of 5 years. |
| 29 | S & F industrial batten designed to provide flicker free, consistent light output with integral fixed output driver, LED light engine source having 120° beam angle, 120° luminaire light beam spread, 4000 lm luminous flux, power consumption ≤ 34W, rated nominal luminous efficacy ≥ 120 lm/W, colour rendering index (CRI) > 80, correlated colour temperature (CCT) 6500K, Power Factor ≥ 0.95, initial chromaticity < 5, median useful life L70B50 @ Ta = 45°C ≥ 50000hrs, surge protection level until 4kV differential mode and 4kV common mode with steel housing, polycarbonate optical cover, surface & suspended (asymmetric / symmetric) mounting device, IP20 & IK02 protection, IEC Safety class I, suitable for 140- 270V input voltage, 50Hz line frequency, ambient temperature range 0 to 45 °C along with all necessary accessories complete all as specified and directed by the engineer-in-charge.Make: Signify BN308C LED40S-6500 L120 PSU WH or Techno-commercial Equivalent model of iGuzzini, Trilux or ENDO LightingNOTES:[i] The contractor shall furnish an LM80 report issued by the OEM and LM79 report from an NABL accredited laboratory.[ii] The standard warranty of the light fitting shall be of 5 years. |
| 30 | S & F moisture-proof wall light (bathroom light) with a sleek and elegant design, LED integrated lamp base & built-in LED bulb, 1000 lm luminous flux, power consumption ≤ 10W, rated nominal luminous efficacy ≥ 100 lm/W, correlated colour temperature (CCT) 4000K, colour rendering index (CRI) < 80 with chrome plated MS housing & PC diffuser, IP 44 protection suitable for 220- 240V input voltage, 50Hz line frequency along with all necessary accessories complete all as specified and directed by the engineer-in-charge.Make: Signify 582109 or Techno-commercial Equivalent model of iGuzzini, Trilux or ENDO Lighting[i] The contractor shall furnish an LM80 report issued by the OEM and LM79 report from an NABL accredited laboratory.[ii] The standard warranty of the light fitting shall be of 5 years. |
| 31 | S & F T8 LED 2 feet batten light with a sleek and elegant design, LED integrated lamp base & built-in LED bulb, 950 lm luminous flux, power consumption ≤ 10W, rated nominal luminous efficacy ≥ 100 lm/W, correlated colour temperature (CCT) 3000K, colour rendering index (CRI) >80 with Polycarbonate housing, IP 20 protection suitable for 220- 240V input voltage, 50Hz line frequency along with all necessary accessories complete all as specified and directed by the engineer-in-charge.Make: BN012C LED10/WW L600 G3 or Techno-commercial Equivalent model of iGuzzini, Trilux or ENDO Lighting[i] The contractor shall furnish an LM80 report issued by the OEM and LM79 report from an NABL accredited laboratory.[ii] The standard warranty of the light fitting shall be of 5 years. |
| 32 | S & F neatly designed step light having long life LED source, beautiful light pattern, robust finish, aluminum housing, LED integrated lamp base, luminous flux ≥ 85 lm, initial correlated colour temperature (CCT) 3000K, power consumption ≤ 3W, IP44 protection with electrical connection complete all as specified and directed by engineer-in-charge.Make: Signify 34152 (IP44) or Techno-commercial Equivalent model of iGuzzini, Trilux or ENDO Lighting[i] The contractor shall furnish an LM80 report issued by the OEM and LM79 report from an NABL accredited laboratory.[ii] The standard warranty of the light fitting shall be of 5 years. |
| 33 | S & F of emergency exit sign having 3 hrs duration, LED light source engine with luminaire light beam spread 55°, upward light output ratio 0.01, luminous flux 85 lm, luminous efficacy ≥ 32 lm/W, luminous flux tolerance ±5%, initial chromaticity ≤ 0.33, colour rendering index (CRI) > 80, initial colour rendering index tolerance ±2%, correlated colour temperature 6500 K, standard tilt angle post top 0°, standard tilt angle side entry 0°, power factor 0.4, internal control interface (no external connection), suitable for input voltage 220-240 V at line frequency 50 Hz having initial / average / end CLO power consumption 4W, inrush current 4 A, inrush time 100 ms, power consumption 4W, 2 Push-in connector 3-pole connection, lithium battery (LiFePO4) suitable for 4W power consumption during central DC emergency mode, 85 lm emergency lux, polycarbonate housing, UV stabilized polycarbonate optic cover, having overall dimensions 30 X 186 X 330 mm (H X W X D) complete all as specified and directed by the engineer-in-charge.Make: EM155C SLIM WL EXIT SIGN M3 ELP UP WH or Techno-commercial Equivalent model of iGuzzini, Trilux or ENDO Lighting[i] The contractor shall furnish an LM80 report issued by the OEM and LM79 report from an NABL accredited laboratory.[ii] The standard warranty of the light fitting shall be of 5 years. |
| 34 | S & F LED security light having LED light source engine, integral driver, 2400 lm luminous flux, 120 lm/W luminous efficacy, correlated colour temperature 5700K, colour rendering index (CRI) > 70, power consumption ≤ 20W, power factor ≥ 0.95, surge protection 4/4 kV, safety class I, median useful life L70B50 @ 50000 hrs, IP 66 & IK 02 protection, aluminium pressure die cast housing, polycarbonate optical cover, spigot for diameter 34 mm to 42 mm, symmetric wide outdoor distribution, suitable for input voltage 140- 270 V and line frequency 50 Hz including necessary electrical connection to the fixture with 3 core flexible Cu conductor cable of appropriate size and 1.5 m long bracket, having 40 mm diameter light grade GI pipe, including GI clamps, nuts, bolts & washers with two coats of synthetic enemal paint over a coat of red oxide primer complete in all respect as specified and directed by engineer-in-charge.Make: Signify BRP330 LED24 CW R5N PC PSU S1 or Techno-commercial Equivalent model of iGuzzini, Trilux or ENDO Lighting[i] The contractor shall furnish an LM80 report issued by the OEM and LM79 report from an NABL accredited laboratory.[ii] The standard warranty of the light fitting shall be of 5 years. |
| 35 | S & F modular type 25 A 1-way SP switch with indicator conforming to IS 3854: 2012 with finger-proof terminal complete all as specified in IS 732: 2019 and directed by the engineer-in-charge. Make: Legrand Arteor 5734 67 or Techno-commercial Equivalent model of Schneider, MK Electric by Honeywell |
| 36 | S & F modular type 3 pin 25/32 A socket, conforming to IS 1293: 2005 complete all as specified in IS 732: 2019 and directed by the engineer-in-charge.Make: Legrand Arteor 5734 67 or Techno-commercial Equivalent model of Schneider, MK Electric by Honeywell |
| 37 | S & F 8 module factory made not less than 1.2 mm thick sunken, modular flush sheet galvanized metal enclosure haing zinc coating not less than 120 GSM, , conforming to IS 14772: 2000, having top, bottom, side and back-wall knockouts for conduit entry from any direction, suitable modular cover-plates complete all as specified and directed by the engineer-in-charge. Make: Legrand Arteor 6890 42 or Techno-commercial Equivalent model of Schneider, MK Electric by Honeywell |
| 38 | S & F triple pole & neutral double door, modular type, double door, per phase isolation metallic distribution board conforming to IEC 61439-3, suitable for flush / surface mounting with provision for FP RCCB / RCBO / Isolator / MCB as incomer and SP MCBs as outgoing, reversible metal door, 100 A copper busbar, fully shrouded neutral bar, earth bar, wire set & cable ties for cable management, pre fitted masking sheet, etc. having IK 09 & IP 43 protection complete all as specified in IS 732: 2019 and directed by the engineer-in-charge.NOTES:[i] RCCB / RCBO / Isolator / MCB shall be measured and paid separately. |
| 39 | triple pole & neutral double door PPI DB, 4 wayMake: Legrand Ekinox 5076 70 with PPI kit 5079 44 or Techno-commercial Equivalent model of ABB, Schneider, Siemens |
| 40 | triple pole & neutral double door PPI DB, 6 wayMake: Legrand Ekinox 5076 71 with PPI kit 5079 45 or Techno-commercial Equivalent model of ABB, Schneider, Siemens |
| 41 | triple pole & neutral double door PPI DB, 8 wayMake: Legrand Ekinox 5076 72 with PPI kit 5079 46 or Techno-commercial Equivalent model of ABB, Schneider, Siemens |
| 42 | triple pole & neutral double door PPI DB, 12 wayMake: Legrand Ekinox 5076 73 with PPI kit 5079 47 or Techno-commercial Equivalent model of ABB, Schneider, Siemens |
| 43 | S & F vertical triple pole & neutral, double door metallic modular distribution board conforming to IEC 61439-3, suitable for flush / surface mounting with provision for MCCB up to 160 A as incomer and SP/TP MCBs as outgoing, reversible metal door, fully insulated 200 A copper busbar for each phase, two fully insulated & shrouded neutral bars, two earthbars, cable ties for cable management, prefitted masking sheet, etc. having IK 09 & IP 43 protection complete all as specified and directed by engineer-in-charge.NOTES:[i] MCCB & MCBs shall be measured and paid separately. |
| 44 | vertical triple pole & neutral double door DB, 12 wayMake: Legrand Ekinox 5077 48 or Techno-commercial Equivalent model of ABB, Schneider, Siemens |
| 45 | vertical triple pole & neutral double door DB,6 wayMake: Legrand Ekinox 5077 47 or Techno-commercial Equivalent model of ABB, Schneider, Siemens |
| 46 | S & F MCB for AC applications conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters, etc. complete all as specified in IS 732: 2019 and directed by the engineer-in-charge. |
| 47 | 16 A, 415 V, 50 Hz, 3P MCB (C curve)Make: Legrand DX³ 4086 55 or Techno-commercial Equivalent model of ABB, Schneider, Siemens |
| 48 | 40 A, 415 V, 50 Hz, 4P MCB (C curve) Make: Legrand DX³ 4087 65 or Techno-commercial Equivalent model of ABB, L&T or Schneider |
| 49 | 63 A, 415 V, 50 Hz, 4P MCB (C curve)Make: Legrand DX³ 4087 83 or Techno-commercial Equivalent model of ABB, L&T or Schneider |
| 50 | 16 A, 230 V, 50 Hz, 1P MCB (D curve)Make: Legrand DX³ 4087 16 or Techno-commercial Equivalent model of ABB, Schneider, Siemens |
| 51 | 32 A, 415 V, 50 Hz, 4P MCB (D curve)Make: Legrand DX³ 4087 91 or Techno-commercial Equivalent model of ABB, Schneider, Siemens |
| 52 | 40 A, 415 V, 50 Hz, 4P MCB (D curve)Make: Legrand DX³ 4087 92 or Techno-commercial Equivalent model of ABB, Schneider, Siemens |
| 53 | S & F residual current device (RCD) conforming to IS 12640 (Part 2): 2016, assembled for AC applications having front face indication for earth leakage fault, sliding shutters, IP 20 protected terminals suitable for cable sizes up to 35 mm² , colour coded on / off indication on dolly, integrated label holder, etc. complete all as specified in IS 732: 2019 and directed by the engineer-in-charge.- 32 A, 30 mA. 230 V, 50 Hz RCCBMake: Legrand DX³ 4113 26 or Techno-commercial Equivalent model of ABB, Schneider, Siemens |
| 54 | S & F moulded case circuit breaker (MCCB), four pole, in single frame size up to 250 A with thermal magnetic trip unit (TMD), compression lug connectors, protection against overloads (Ir adjustable from 0.7- 1 X In), protection against short circuits (Isd adjustable from 1.5- 10 X Ir), inbuilt encapsulated double break roto active type instanteneous protection, earth fault leakage protection, etc. having Ics = 100% Icu = 25 kA as per IEC 60947-2 complete all as specified and directed by engineer-in-charge.- 40 A, 415V, 25 kA, 50 Hz 4P MCCBMake: Legrand DPX³ 4200 52 or Techno-commercial Equivalent model of ABB, L&T or Schneider |
| 55 | S & F moulded case circuit breaker (MCCB), four pole, in single frame size up to 250 A with thermal magnetic trip unit (TMD), compression lug connectors, protection against overloads (Ir adjustable from 0.7- 1 X In), protection against short circuits (Isd adjustable from 1.5- 10 X Ir), inbuilt encapsulated double break roto active type instanteneous protection, earth fault leakage protection, etc. having Ics = 100% Icu = 25 kA as per IEC 60947-2 complete all as specified and directed by engineer-in-charge.- 63 A, 415V, 25 kA, 50 Hz 4P MCCBMake: Legrand DPX³ 4200 53 or Techno-commercial Equivalent model of ABB, L&T or Schneider |
| 56 | Supply, installation, testing and commissioning 3 channel DALI high frequency ballast controller for T4 / fluorescent / LED lamps with 3# 20A relay, allowing to control up to 192 DALI devices with 3 channels altogether, having DIN-rail mountable integral DALI bus power supply removing the need for an additional external device, programmed to operate automatically isolate the power circuit when all associated DALI channels are at 0%, suitable for 100 to 240 V, 50 / 60 Hz, 1-Ph supply at 0.1 A complete with accessories all as specified and directed by the engineer-in-charge.- The DALI high frequency ballast controller shall consist of the following:[i] Control Outputs: 3 X DALI control outputs, each supporting a full DALI universe of 192 channels including backward channel DALI bus power supply[ii] Internal 24 V rated 250 mA Control IO: 1 X RS485 DyNet serial port / DMX, 1 X AUX programmable dry contact input[iii] DC supply 12V @ 200 mMake: Philips Dynalite DDBC320-DALI & DDNPI501 or Techno-commercial Equivalent model of iGuzzini, Trilux or ENDO Lighting |
| 57 | Supply, installation, testing and commissioning of wall-mounted 6 button keypad, mounted on a 2 module GI box, having front cover with backlight, built-in proximity & temperature sensors capable of automatically adjusting air-conditioning when integrated into the system, loaded icons like presentation scenario / meeting scenario / master on-off, power saving mode, etc. along with an LED indicator for each operation, available with icon labelling customization, having fully programmable options for individual control / group control / scene control / tasks, etc. and suitable for operating on 12 to 24 V DC SELV class II @ 32 / 20 mA from network complete with accessories all as specified and directed by the engineer-in-charge.Make: Philips Dynalite PAxBLE (AntumbraLite Euro) & DACM-DyNet or Techno-commercial Equivalent model of iGuzzini, Trilux or ENDO Lighting |
| 58 | M & L RoHS compliant and UL listed category 6A, 4 pair F/UTP (shielded) LSZH 23 AWG twisted pair cable, having bare copper conductor, polyolefin insulation, LSZH jacket, aluminium / polyester shield (tape), characteristic impedance 100 ±15% Ω , maximum DC resistance 7.8 Ω/100 m, maximum delay skew 45 ns, normal velocity of propagation (NVP) 69%, maximum operating voltage 80 V, segregation Class c, fully compliant with the recommendations set forth by IEEE 802.3bt (Type 4) for the safe delivery of power over LAN cable when installed according to ISO/IEC 14763-2, CENELEC EN 50174-1, CENELEC EN 50174-2 or TIA TSB-184-A complete all as specified and directed by the engineer-in-charge.Make: Commscope, D-Link, Legrand |
| 59 | Supply, installation, testing and commissioning of fully microprocessor-based, online double conversion, indoor, compact UPS of 20 kVA rating with latest generation 3-level IGBT (high-frequency PWM) inverter bridge technology, connected in parallel to have N+X redundancy up to a maximum of 4 units with built-in isolation transformer, VRLA-AGM lead-acid, sealed, maintenance-free batteries of suitable size and quantity along with mounting rack(s) to provide 30 minutes back up time, connecting cables (for UPS to battery and battery to battery) suitable size, 5” touch-screen display to monitor UPS status in real-time, relay contact board, Modbus RS485, SNMP-ethernet, USB, net interface, configurable acoustic alarms and signals, complete with all necessary components and accessories as specified and directed by the engineer-in-charge.Make: Numeric, Reillo, Schneider- The UPS shall conform to the following specification:[A] General Features[1] Power: 20 kVA[2] UPS Topology: ON LINE- Double Conversion[3] Nominal Apparent Output Power: 20 kVA / 20 kW (unity power factor)[4] Efficiency in Double Conversion Mode: Up to 94%[5] Efficiency of AC to AC conversion in Eco Mode: > 98%[6] UPS Operating Temperature: 0 to 40 °C[7] Relative Humidity (non-condensing): < 95%[8] Degree of Protection: IP20[9] Audible Noise Level: < 65 dB |
| 60 | [10] Electromagnetic Compatibility EMI: As per IEC EN 62040-2 (CE marking)[11] Safety: AS per IEC EN 62040-1[12] Test and performance: As per IEC EN 62040-3[13] Accessibility: Front access[14] Installation: Against the wall[15] Front Panel: 5\\" touch-screen[16] Serial Communication Interface: RS485 (Modbus RTU protocol)[17] Parallel Configuration: Up to 3+1 (redundant parallel) or up to 4 (power parallel)[B] Input: Rectifier and Battery Charger[1] Power: 20 kVA[2] Input: 3-Ph (3P4W)[3] Nominal Input Voltage: 415 V[4] Input Frequency: 50 Hz[5] Input Frequency Range: ±10%[6] Input Power Factor: > 0.99 @ rated linear load[7] Input THDi < 3% @ rated linear load[C] Batteries[1] Power: 20 kVA[2] Type: VRLA-AGM lead-acid, sealed, maintenance-free batteries[3] Battery Test: As per standard[D] Output Inverter[1] Power: 20 kVA[2] Type: VRLA-AGM lead-acid, sealed, maintenance-free batteries[3] Battery Test: As per standard |
| 61 | [D] Output Inverter[1] Power: 20 kVA[2] Nominal Active Power Output: 20 kW[3] Output: 3P4W[4] Rated Output Voltage: 380-400-415 V (Selectable)[5] Output Voltage Frequency: 50 Hz[6] Overload Capability: Upto 110% for 1 Hour,125% for 10 Min & 150% for 1 Min[7] Output Waveform: Sinewave[8] Maximum Creast Factor without Derating: 3:1[9] Isolation Transformer: Integrated |
| 62 | DG SET |
| 63 | Supply of 'Silent Type Diesel Generating set as per CPCB IV + or betternorms along with having Prime Power Rating of 250 KVA, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phasesystem & for 0.85 Load Factor or nearest higher size available, including testing at factory and site with fuel, load for test and other necessary arrangements Complete as per latest CPCB Norms, should have QR code which should contain drawing, testreport OEM manual, Geo- Tag of manufacturing location, rating plate as per relevant IS Code etc. and consisting of the followings: |
| 64 | (A) Diesel Engine:Turbocharged Diesel engine 4 stroke water cooled, multi cylinder,dynamically balanced fly wheel, electric start of suitable BHP at 1500 RPM suitable for above output of alternator at 40 Degree C, 50% RH & at 1000 Meter MSL , capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be with Electronic governor, Dry type Air filter with service indicator, first filling of engine fuel (after commissioning)lubricating Oil, Coolant and other consumables complete with all therequired accessories, the Electronic governor shall be as per ISO 8528.The engine shall comply to the latest CPCB norms (CPCB IV + or better) and Conforming to BS 5514, BS 649, IS 10000, IS 10002, IS 13018 and as perCPWD specifications. |
| 65 | (B) Engine mounted Instrument Panel fitted with and having digitaldisPlate for following:(i) Start-stop switch with key(ii) Water temperature indication(iii) Lubrication oil pressure indication(iv) Lubrication oil temperature indication(v) Battery charging indication and Voltage indication(vi) RPM indication(vii) Over speed indication(viii) Low lubricantion Oil trip indication(ix) Engine Running Hours indication(x) Fuel Level |
| 66 | (C) Alternator:Synchronous alternator rated of appropriate 250 KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 Degree C, 50% RH & at 1000 Meter MSL. The alternator shall be having Screen Protected Drip Proof (SPDP) enclosure IP23, brushless, continuous duty, dynamically balanced rotor, capable of taking 10% over loading for one hour after 12 hours of continuous operation, self cooled,self-excited and self-regulated through AVR conforming to IS13364(Part 2)/IS: 4722/BS 2613 suitable for tropical conditions and with class- H insulation. |
| 67 | (D) Base Frame & Foundation:Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer. |
| 68 | (E) FUEL TANK:Daily service fuel tank of suitable liters capacity as per CPWD Specifications, fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class 'C' pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications. |
| 69 | (F) Exhaust System:Dry exhaust manifold with hospital type exhaust silencer and catalytic convertor. |
| 70 | (G) Starting System:12V/24V DC starting system comprising of starter motors: voltageregulator and arrangement for initial excitation complete with suitablenumbers of batteries (180 AH capacity lead acid SMF type) as required asper specifications. The battery shall be housed inside the acoustic enclosure of DG Set. |
| 71 | (H) Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere and the temperature rise inside the enclosure, noise level outside enclosure. The acoustic enclosure should be suitable for cable connection/connection through bus-trunking. Such arrangements on acoustic enclosure should be water proof & dust-proof conforming to IP-65 protection. The enclosure shall be as per CPCB IV + or better norms etc. and as per BIS specifications. |
| 72 | (I) AMF Panel:Free standing floor mounted IP 42 automatic mains failure control panel including auto by-pass, suitable for KVA as below for silent type DG set complete with relays, timers, set of CTs for metering & protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, Kilo Volt Ampere Reative Hour (KVARH), KVA (Phase & Total), KW & provision for overload, short circuit, restricted earth fault, under frequency, power (aluminum) and control (copper ) cabling of suitable size upto 15 meter between AMF panel, LT Panel and DG Set including connection interconnection etc. as required, all complete and inter locking and communication/ Ethernet /RS485/SNMP port open protocol for BMS integration including suitable software, the panel shall be of DG Set OEM make etc. as per approved by Engineering in charge and including the following:1. Suitable numbers and appropriate capacity 4 pole motorised electrically operated draw out with cradle type 3 position ACB/ MCCB with electronic release for O/C & E/F and shunt trip.2. Auto/Manual/Test/Off selector switch3. Protection for under and over voltage phase reversal (2 nos Over voltage relay, 2 Nos. reverse power relay and 2 Nos. under voltage relay).4. 3 Sets of current transformers 15 P 10 accuracy for protection and 15VA class-I for metering5. Energy analyser unit to indicate current, Voltage( L-N & L_L), kW, Kva (Phase & Total), Frequency, KWH, PF.6. LED Indicating lamps for load on mains and load on set.7. Fuse/ MCB for instruments.8. Battery charger, complete with transformer/ rectifier, D.C. voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment. |
| 73 | 9. Main supply failure monitor.10. Supply failure timer.11. Restoration timer12. Control unit with three impulse automatic engine start/stop and failure to start lockout.13. Impulse counter with locking and reset facility.14. ON/OFF/Control circuit switch with indicator15. Audio/Video annunciation for(i) High water temperature(ii) Low lubricating oil pressure(iii) Engine over speed(iv) Engine fails to start(v) Full load/maximum load warning16. Protection for over/under Frequency, Loss of AC sensing, OverCurrent, Unbalancing load with suitable number of relays and accessories17. Maintenance notification based on Engine Run Hour & due date.18. Load Management through PLC to achieve auto opening and closing of incomer breakers, bus coupler switching of essential panel , interlocking providing signal to AMF Panel for load status and AMF shall give command to DG Set to auto start / auto stop depending upon load status and requirement etc. and necessary hardware and software required to perform the operation shall be provided by the contractor including all control wiring.19 The quoted unit rate shall include necessary Plain cement concrete (1:2:4) foundation of size 5400mm (L) X 2400mm (W) x 750 nn (H) |
| 74 | M & L for earthing complete with galvanized steel earth plate electrode of 60 cm X 60 cm X 6 mm size, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized strip of size 32 mm X 6 mm as earth lead by means of bolts, nuts, checknuts and washers of galvanized iron or steel, galvanized iron pipe of 40 mm diameter connected to earthing test point, all as shown in electrical plate No. 5, connected to earthing test point including testing on completion, excavation, earthwork, PCC earth pit of dimensions 550 mm X 550 mm (outer) and 300 mm X 300 mm (inner) and 250 mm deep with a 10 mm deep CI cover hinged to CI frame on ground level, GI watering pipe, funnel, etc. complete all as specified and dir |
| 75 | External Water Supply |
| 76 | Material and labour for construction of 600 mm X 600 mm X 600 mm valve chambers including excavation and earthwork. PCC foundation 1:4:8 type D2 using 40 mm graded stone aggregate, 150 mm thick & 150 mm wide offsets around over 100 mm thick hardcore , 200 mm thick PCC block masonry walls built in CM 1:4, 100 mm thick PCC 1:2:4 Type B1 coping finished even and smooth, rendering 10 mm thick in cement mortar (1:6) finished even and smooth, with out using extra cement internally including top of floor including excavation earth work in hard/dense soil 6 mm thick MS sheet cover fixed on 25 mm X 25 mm X 6 mm thick angle iron frame with hold fasts embedded in PCC coping with locking arrangement, mild steel handle and painting to steel surfaces with two coats of synthetic enamel paint over one coat of primer including disposal of surplus soil to a distance not exceeding 50 m etc complete all as specified and directed. |
| 77 | Supply, installation, testing and commissioning of Monoblock, self-priming, single-stage centrifugal pump, capable of 2.8 LPS discharge at 13 MWC head, 1 HP pump having cast iron casing, enclosed type dynamically balanced cast iron impeller, carbon steel pump shaft, gland packed sealing, deep groove ball bearings, etc. with SPDP squirrel cage induction motor having class 'B' insulation, IE3 efficiency, conforming to IS 12615: 2018 and suitable for operation on 3-Ph, 415 V±10%, 50 Hz AC supply, base plate, mounting channel frame, accessories and fittings, viz. pressure gauges, drains, coupling, coupling guard, vibration isolation arrangement by means of spring / rubber type mounting along with accessories complete all as specified and directed by engineer-in-charge.MAKE:- monoblock pump (1W+1S)NOTES:[i] Necessary civil work viz. foundation for placement of pump and accessories shall be covered in the scope of work. |
| 78 | Fire Fighting System |
| 79 | Supply, installation, testing, and commissioning of Fully automatic DOL starter, suitable for the booster pump, complete with contactors, push button, LED type indicators, auto/manual selector switch, overload protection, current sensing type single phase preventer complete with all accessories and wiring etc.with complete all as specified and directed by the engineer-in-charge. |
| 80 | M & L for low smoke zero halogen (LS0H) fire survival control cable with circuit integrity, conforming to BS 7846 and rated for 600 V, having plain annealed stranded copper conductor with fire-resistant mica tapes covered by an extruded layer of cross-linked polyethylene, extruded layer of thermoplastic low smoke zero halogen (LS0H) compound, single layer of galvanized steel wires and thermoplastic LS0H compound sheath, suitable for operating temperature range -40 ˚C to +90 ˚C and minimum bending radius being 12 times the overall cable diameter, including laying, clamping, termination and ferruling complete as specified and directed by the engineer-in-charge. |
| 81 | 2 core, 2.5 mm² (for instrumentation) |
| 82 | 3 core, 2.5 mm² (for auto start/stop panel) |
| 83 | 12 core, 2.5 mm² (for diesel engine pump) |
| 84 | M & L for 1.1 kV grade fire survival cable with fire rating FS (950/FWS) conforming to IS 17505-1: 2021, and having electrolytic annealed plain / tinned copper (Class 1/2) conductor conforming to IS 8130: 2013, mica tape layer (s) primary insulation, cross linked PE (XLPE) / cross linked HFFR secondary insulation, thermoplastic HFFR inner sheath, glass fibre heat barrier tape, galvanized round wire armour, thermoplastic HFFR (HFS-TP 90) / Cross Linked HFFR (HSF-XL 90) outer sheath including necessary clamping / dressing with cable ties and termination complete as all specified and directed by engineer- in- charge. |
| 85 | 3 core, 35 mm² FS (950/FWS) Cable |
| 86 | 3 core, 6 mm² FS (950/FWS) Cable |
| 87 | 3 core, 4 mm² FS (950/FWS) Cable |
| 88 | S & F of perforated hot dipped galvanized iron cable tray having galvanization thickness not less than 50 microns and perforation not more than 17.5% including fittigs viz. joints, bends, tees, etc. in convenient sections of length complete including cable tray supports supports and associated accessories, all as specified and directed by the engineer-in-charge. |
| 89 | 300 mm X 50 mm X 1.6 mm |
| 90 | 150 mm X 50 mm X 1.6 mm |
| 91 | 100 mm X 50 mm X 1.6 mm |
| 92 | M & L for PN 1.6 rated 200 mm NB polypropylene Vortex inhibitor suction lift, conforming to BS 4504 with stainless wire mesh, bolts, nuts and washers, etc. complete all as specified and directed by the engineer-in-charge. |
| 93 | M & L for FM approved and UL listed, PN 1.6 rated lever operated, wafer type CI Butterfly valve, conforming to IS 13095: 1991,fitted with visual indicator & temper switch, having Cast iron (CI) body with ductile iron EPDM coated disc, SS431 stub shaft, PTFE bushing, flange drilling standard end connection conforming to IS: 1538- 1993 along with necessary accessories complete as specified and directed by the engineer-in-charge (for Zone control valve assembly).- 100 mm NB |
| 94 | S & F of CL 150 # rated ball valve, designed & manufactured as per IS: 9890 (1981) and tested as per BS 6755 Part- I, having floating type three piece design, CS body, SS- 304 ball, PTFE seal / packing / gasket, CS fastners and lever and screwed/socket weld end connection, etc. with accessories complete all as specified and directed. |
| 95 | 25 mm NB |
| 96 | 40 mm NB |
| 97 | M & L for 50 mm NB PN 1.6 rated GI Puddle Flange designed & manufactured as per BS 1560-3.1 & BS 4504 for suction of fire pumps from water tank all complete all as specified and directed by the engineer-in-charge. |
| 98 | S & F of orifice plate made out of 6 mm thick SS 304 with orifice of required size to be fitted between flange and landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as specified and directed by the engineer-in-charge. |
| 99 | S & F non-percolating rubber reinforced lined RRL hose type-B 15 m long fire hose of 63 mm NB size, conforming to IS 636: 1988, rated for bursting pressure of 35.7 kg/cm² complete with gunmetal male & female coupling conforming to IS: 903- 1993, bound and rivetted to the hose pipe with copper rivets and 1.5 mm² copper wire complete as specified and directed by the engineer-in-charge. |
| 100 | Supply, installation, testing and commissioning of FM approved and UL listed Network Control Display (NCD) / Repeater Panel capable of full supervision of all inputs and network integrity, having 10\\" high definition 1024 X 600 colour touchscreen display, environmental adjustment controls to maximize LCD legibility, LED status indicators (for power supply and off normal condition), network connection, three USB connections, trouble relay, tamper and trouble inputs, etc. and features viz. network-wide acknowledge silence, reset, lamp test, fully programmable node-mapping subsystem, colour coded icon based event notification, event vectoring, etc. along with UL listed non-resettable 24 VDC power source complete all as specified and directed by the engineer-in-charge. |
| 101 | Supply, installation, testing and commissioning of FM approved & UL listed Remote power supply conforming to UL 864 & 1481 and NFPA 72 with integral battery charger capable of charging up to 18 Ah batteries to provide regulated and filtered 24 VDC power to notification appliance circuits, having power-supervision relay, fully regulated and filtered power output, AC trouble report selectable for immediate 2-hour delay, selectable earth fault detection, etc. complete all as specified and directed by engineer-in-charge. |
| 102 | M & L flame retardant, low smoke & low halogen fire alarm armoured cable having stranded class 2 copper conductor conforming to EN 60228, insulated with XLPE type GP8 conforming to BS 7655-1.3, extruded inner sheath with PVC conforming to BS 5467, armoured with galvanised steel round wire and sheathed with extruded FRPL PVC conforming to BS 5467, suitable for voltage rating 600/1000 V, maximum operation temperature 90 °C, maximum conductor temperature at short-circuit 250 °C, RED in colour, including laying, termination and ferruling complete all as specified and directed by engineer-in-charge. |
| 103 | 2 core, 1.5 mm² |
| 104 | 2 core, 2.5 mm² |
| 105 | Supply, installation, testing and commissioning of UL listed (fire fighter's) addressable Telephone Jack mounted to a single-gang electrical back box with suitable interface module for two way communication with the Central Fire Fighter Telephone Console complete all as specified and directed by engineer-in-charge. |
| 106 | Supply, installation, testing and commissioning of UL listed Fire Fighter's Telephone Handset for two way communication with the Central Fire Fighter Telephone Console complete all as specified and directed by engineer-in-charge. |
| 107 | M & L for transparent FR PVC insulated, twin core copper conductor flexible Speaker cable having stranded annealed tinned copper conductor, PVC insulated cores twisted to form pairs, shielded for interference rejection, unarmoured PVC sheathed 1.1 kV grade in conductor size 2 X 1.0 mm2 including laying, termination and ferruling complete all as specified and directed by engineer-in-charge. |
| 108 | S & F 6 kg capacity dry chemical powder (ABC) type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted in gunmetal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket / floor trolley mounting accessories along with suitable signage, etc. complete all as specified and directed by the engineer-in-charge. |
| 109 | S & F of 4.5 kg light-weight squeeze grip CO2 type fire extinguisher, conforming to IS 15683: 2006, with CO2 gas filled in brand new seamless cylinder with powder coated finish, made out of Manganese steel with wheel type valve, discharge nozzle, bend & horn, wall mounting bracket / floor trolley mounting accessories along with suitable signage complete all as specified and directed by the engineer-in-charge. |
| 110 | S & F of the following type of Signages made out of 3 mm thick opaque PVC foam board with computer cut, PVC non-reflective self adhesive vinyl painted foam board, complete with mirror fasteners complete all as specified and directed by the engineer-in-charge. |
| 111 | Sign of size 300 mm X 100 mm reading 'EXIT' in 12.5 mm block letters in Green and white background, properly spaced to provide good legibility located directly in corridor near to each staircase and squarely attached to the wall or partition in a way that the top of the sign is not above 2 m from the finished floor level |
| 112 | S & F of Signage having size of 450 MM X 150 MM reading \\"FIRE EXTINGUISHER\\" in 12.5 mm block letters in White and Red background, made out of 3 mm thick opaque PVC foam board with computer cut, PVC non-reflective self adhesive vinyle painted foam board,properly spaced to provide good legibility located directly in corridor near to each Manual call point/Fire Extinguisher and squarely attached to the wall or partition in a way that the top of the sign is not above 2 m from the finished floor level |
| 113 | S & F of Signage having size of 150 mm X 600 mm, posted and maintained at each lift landing and on the side of the stairway door from which egress is to be made on every floor, indicating the \\"STAIRCASE\\" by an alphabetical letter in bold type and at 75 mm high letters in red and white background, made out of 3 mm thick opaque PVC foam board with computer cut, PVC non-reflective self adhesive vinyle painted foam board,securely attached to the side of the stairway door from which egress is to be made in a way that the bottom of the sign is not above 1.5 m from the finished floor level |
| 114 | Air Conditioning System |
| 115 | VRF OUTDOOR UNITSupply, installation, testing and commissioning of following VRF / VRV outdoor units, having R410 refrigerant, multiple Nos. of inverter, digital scroll compressors, air cooled condenser fan with motor, microprocessor control panel, starter controls for all scroll compressors and condenser fan motors along with internal control and power wiring, cooling coil with internally interconnected refrigerant pipes for interconnecting various capacity modules, charging port and all other required accessories, & hardware, first charge of refrigerant and all other required accessories, hardware like T joints etc., all enclosed in an enclosure with weather resistant powder coating paint for withstanding all ambient conditions for continuous outdoor operation, suitable to operate on 3-Phase, 380-415 V, 50 Hz AC power supply complete all as specified and directed by the engineer-in-charge.NOTES: [i] The VRF/ VRV system shall be provided with mounting base and antivibration pad(s). All the accessories, hardware, software, consumables etc. whether specifically mentioned or not but required to put the VRF / VRV System into service up to the satisfaction of the Engineer-in-charge including testing, commissioning as per specifications, site constraints shall be deemed included in the scope of the work.[ii] Nothing extra shall be payable for these systems under any circumstances. All the consumables including first charge of refrigerant (R410) and oil for the proposed VRF / VRV system shall be deemed inclusive in the scope of work. The topping of refrigerant and oil shall also be included in the scope of work for arresting leakages if any. The unit shall be lifted using crane / sufficient manpower and installed on suitable pedestal / MS rail / bots & nuts etc, all complete as requirement of site conditions. - VRF / VRV outdoor units of min. 114 HP combined heating + cooling capacity (3# 38 HP units) at site conditions |
| 116 | CONTROL CABLESupply installation & commisioning of ISI shield control cables between indoor & outdoor unit lay in hard PVC pipe for VRF AC system complying all specification directed by the engineer-in-charge.- 2 core, 1.0 mm2 , 2XWY cable |
| 117 | STAND FOR ODUM & L for MS table top stand for VRF condensing outdoor unit complete all as specififed and directed by engineer-in-charge. |
| 118 | REFRIGERANT COPPER PIPINGSupply, installation, testing and commissioning of refrigerant copper piping (duly insulated with 19 mm thick closed cell elastomeric nitrile rubber tubular insulation) of hard drawn / soft drawn copper pipe, laid on walls / roof / ceiling well supported at specific intervals with metallic supports and screwed with anchor fasteners and necessary accessories, jointing / brazing etc., including connection between outdoor unit to indoor units as required complete all as specified and directed by the engineer-in-charge.NOTES: [i] The sizing of refrigerant copper piping shall be confirmed / vetted by the OEM.[ii] All piping inside the ceiling shall be properly supported using necessary clamps and all externals refrigerant lines shall be properly protected using necessary PVC (HDPE) pipes with accessories to suit the site conditions.[iii] The quantity of these items of works shall be measured as per actuals requirements of site conditions. The vendor shall accept the accepted rate as per the actual measured quantities. |
| 119 | 12.7 mm dia. |
| 120 | 15.9 mm dia. |
| 121 | 19.1 mm dia. |
| 122 | 22.2 mm dia. |
| 123 | 25.4 mm dia. |
| 124 | 28.6 mm dia. |
| 125 | 38.1 mm dia. |
| 126 | 44.5 mm dia. |
| 127 | 54.0 mm dia. |
| 128 | OUTDOOR UNIT REF-NET JOINTSSupply, installation, testing and commissioning of variable refrigerant flow distribution Ref-nets (Y-joint) in the gas and liquid lines for outdoor unit complete all as specified and directed by engineer-in-charge. |
| 129 | DRAIN PIPEM & L for 40mm Dia. PVC drain water pipe including bends, collars & elbow etc, all complete and duly insulated with 9 mm thick tubular insulation of closed cell elastomeric nitrile rubber as required for 40 mm dia. |
| 130 | DOUBLE SKIN AIR HANDLING UNITSupply, installation, testing and commissioning of double-skin type horizontal, floor-mounted, top / side discharge, air handling unit (AHU) capable of delivering 12000 ft3/min @ 150 Pa external static pressure and having thermal break profile complete with air-tight casing using gaskets and self-adhesive tapes, 0.8 mm thick pre-plasticized GI sheet for outer skin and 1 mm thick aluminum sheet for inner skin, 45±2 mm thick double skin panel with pressure injected CFC / HCFC free PUF having 'k' value ≤ 0.035 W/°C/m & density ≥ 40 kg/m³, energy efficient backward curved electronically commutated (EC) plug fans integrated with continuous speed control in (n+1) configuration, frame mounted modular EU4 pre-filter, EU7 fine-filter, UVGI system, combination of 6/8 rows deep DX coil(s) of cooling capacity ≥ 60 TR & heating capacity ≥ 50 kW, electric heater bank for humidity control, PVC / nylon hinges & handles, view port & marine lamp, limit switch, SS-304 drain pan, vibration isolators / rubber pads (minimum 1\\" thick) inspection windows / doors, mixing box and supply / return / fresh air openings fitted with aluminium volume control dampers, thermostat & humidistat, AHU Panel etc. complete all as specified and directed by the engineer-in-charge. |
| 131 | The AHU shall comprise of the following:[a] AMCA certified (for sound & vibration) single inlet single width (SISW) multi blade backward curved type IP54 integral EC motor direct drive, having an integral high efficiency permanent magnet electrically commutated motor complete with control electronics, sealed bearings and all necessary motor protection and safety devices, single point power connection (for multiple EC motors incorporated into a fan array of (n+1) configuration), Modbus RTU compatible for communication with BMS, class 'F' thermal insulation, suitable protection from moisture & hot climate, over/under voltage protection, short-circuit protection, locked rotor protection, locked rotor protection, line fault detection, active temperature management for thermal protection or motor and electronics, alarm relay 250V/2A, over-temperature protection, external LED display, etc meeting all necessary EMC (electromagnetic compatibility) directives & applicable EMC standards e.g., EN 61000-6-3. |
| 132 | [b] Flexible connection made with airtight ASTM E84 (Class I) polyester fire retardant cloth riveted on periphery of cloth with extruded aluminium 'L' angle flange as per fan size at discharge duct / plenum |
| 133 | [c] CE certified, UL listed self-cleaning (washable) filter meeting EU4 criteria at velocities < 2.5 m/s, start pressure drop approximately 50 to 150 Pa, final pressure drop approximately 150 Pa, having particulate efficiency 90% down to 10 micron |
| 134 | [d] CE certified, UL listed electrostatic air cleaner filter meeting EU7 criteria at velocities between 2.0 to 3.0 m/s, start pressure drop approximately 50 to 100 Pa, final pressure drop approximately 150 Pa, having particulate efficiency 99.9% down to 3 micron |
| 135 | [e] High output Ultraviolet Germicidal Irradiation (UVGI) lamp mounted on a dish antenna shaped parabolic reflector made of anodized aluminium with high spectral reflectivity suitable for use in low temperature applications |
| 136 | [f] 6 / 8 rows deep direct expansion coil(s) section with 0.15 mm thick aluminium fins and 12.7 mm OD copper tubes (0.41 mm thickness) tested on 21 kg/cm², with SS sandwiched drain tray, etc. (a 350 mm service section between eliminator). |
| 137 | [g] Condensate drain pan fabricated from 18 gauge SS 304, powder coated and insulated with elastomeric insulation of suitable thickness |
| 138 | [h] AHU panel made out of 2.00 mm thick mild steel CRCA sheet, duly powder coated in compartmentalised construction with incomer and outgoing feeders for AHU motor, AHU filters, fire damper actuator, electric heater etc. complete with required drives, relays, timers, contactors, PT, push buttons, switches, internal wiring, etc. |
| 139 | NOTES: |
| 140 | [i] The AHU shall meet the efficiency crieria laid for the Super ECBC Building category in ECBC 2017. |
| 141 | [i] The AHU shall meet the efficiency crieria laid for the Super ECBC Building category in ECBC 2017. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
| 7 | Click here to download tender document | Tender Documents |
| 8 | Click here to download tender document | Tender Documents |
| 9 | Click here to download tender document | Tender Documents |
| 10 | Click here to download tender document | Tender Documents |
| 11 | Click here to download tender document | Tender Documents |
| 12 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail