| 1 | GENERAL SUMMARY (Note : Schedule 'A' Part I 'Building/ Structure' is not pre priced by MES and the pre priced rate indicated as \\"Rs. 0.00\\" under Col.5 signifies this fact only. Bidder shall insert their rate in Green field under column 6)Schedule ‘A’ Part I “BUILDING/STRUCTURES ” |
| 2 | Construction of RCC M-25 framed Structure (single storey) for PUMP HOUSE with permanent Specifications in RCC M-25 , with AAC block masonry walls, ATT, PU based WPT, earthquake resistance as per latest IS, incl RCC foundation etc complete all as specified and as shown in Architectural and structural drawing. |
| 3 | Construction of RCC M-30 Construction of RCC UG sump of 1,10,000 litre capacity complete all as specified and as shown shown in Architectural and structural drawing. |
| 4 | GENERAL SUMMARY (Note : Schedule 'A' Part II to IX are prepriced by MES under Ser No. 05 to 12. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only) |
| 5 | Total of Schedule ‘A’ Part II “INTERNAL WATER SUPPLY ” |
| 6 | Total of Schedule ‘A’ Part III “INTERNAL ELECTRIFICATION\\" |
| 7 | Total of Schedule ‘A’ Part IV “ HARDSTANDING ” |
| 8 | Total of Schedule ‘A’ Part V “APPROACH PATH ” |
| 9 | Total of Schedule ‘A’ Part VI “SEWAGE DISPOSAL ” |
| 10 | Total of Schedule ‘A’ Part VII “ EXTERNAL WATER SUPPLY” |
| 11 | Total of Schedule ‘A’ Part VIII “ EXTERNAL ELECTRIFIC SUPPLY” |
| 12 | Total of Schedule ‘A’ Part IX “ FIRE FIGHTING” |
| 13 | Sch 'A' Part- X - MISCELLANEOUS ITEMS (Note : This schedule is not pre priced by MES and the pre priced rate indicated as \\"Rs. 0.00\\" under Col.5 signifies this fact only. Bidder shall insert their rate in Green field under column 6) |
| 14 | S&F DWC HDPE pipe as per IS-16098 (Part-2), stiffness class SN-8, 150 mm (ID) laid in trenches and jointed complete all as specified and directed. |
| 15 | S&F Ductile Iron Pressure Pipes, Centrifugally Cast [Spun], Class \\"K-7\\" for 150mm bore with Socket and Spigot ends conforming to IS - 8329 in standard lengths suitable for Push-On Rubber Gasket Jointing with inside Cement Mortar Lining and Black Bitumen external coating of any description and any size complete all as specified and as directed. Note : Excavation earth work and DI special shall be measured separately. |
| 16 | S&F DI fittings Bend,(any type ,radius and angle) tapers any type (straight, bend, increasing, decreasing or double socket etc), Tee pieces, connection pieces, collers, caps and plugs complete all as specified and directed |
| 17 | M&L for Riddling Sand / soil obtained from excavation and cushioning of UG cable with a layer of 8 cm deep before laying the cable and 15 cm depth after punning down and stretching the cable complete all as specified and as directed. |
| 18 | S&F CI Dual Plate Wafer Check Valve PN 16 [DP] size 100 mm dia including washer etc complete all as specified and as directed. |
| 19 | S&F CI Dual Plate Wafer Check Valve PN 16 [DP] size 80 mm dia including washer etc complete all as specified and as directed. |
| 20 | S&F 100 mm bore foot valve suitable for MS pipe flange conforming IS 4038 type complete all as specified and directed |
| 21 | S&F 80 mm bore foot valve suitable for MS pipe flange conforming IS 4038 type complete all as specified and directed . |
| 22 | Supply and installation of Air cushion vessel/tank with relief valve 100 mm dia complete all as specified and directed. |
| 23 | Supply and installation of Air cushion vessel/tank with relief valve 80 mm dia complete all as specified and directed. |
| 24 | S&F Air release valve 25 mm dia for wet raiser line with other accessories as per IS:778-1984 all as specified and directed. |
| 25 | S&F swivel type 02 Nos hose drum with hose reel of 20 mm dia and 30 mtr length conforming to IS 5132 complete all as specified and as directed. |
| 26 | Supply, erection, testing and commissioning of 63 mm dia long range operation, 360 Degree rotating manually operated water monitor (ISI marked) suitable for 100 mm dia pipe line with dual jet suitable for water and foam discharge (UL/FM/CE certified or LPCB approved for foam water application, foam liquid containers fitted with listed proportioning devices 300 litre of AFFF concentrate (UL) including 300 litre capacity container/box made of MS sheet minimum 3.5 mm thick and slim sheet type butter fly valve 150 m dia (ISI marked) with sheperodical graphite iron disc (SG iron) with nitrile rubber seal and tested to PN 1.6 including set of suitable GI flanges as per BS-10 table-1 bolts nut GI washer gaskets etc complete all as specified and directed |
| 27 | S&F Differential pressure switch (DP switch) for auto operation of fire pumps of approved makes, ISI marked with fittings complete all as specified and as directed. |
| 28 | M&L for route indicator for fire pipe line comprising of die cast aluminium plate circular shape of thickness 6 mm and dia 150 mm marked with \\"Fire Pipe\\" in red colour supported on and including die cast aluminium of dia 15 mm and length 1 mgr. grouted on concrete block of 0.15x0.05x0.15 m with PCC 1:3:6 type CI using 20 mm graded stone aggregate including fixing of pipe complete all as specified and as directed. |
| 29 | M&L for Construction of Valve Chamber of size 900mmx 900mmx 900mm (internal) internal size suitable for Sluice Valve, with 150 mm thick PCC 1:4:8, Type D2, using 40mm graded stone aggregate for foundation, 200 mm thick Brickwork with fly ash bricks using modular bricks in Cement Mortar 1:6, 40 mm thick PCC, 1:2:4, Type B1, using 20mm graded aggregate Coping, rendering in CM 1:4, 15 mm thick including provision of Mild Steel Sheet Cover 3 mm thick with 40 X 40 X 6 mm size Angle Iron frame work embedded in concrete with suitable hinges and locking arrangements including two coat of synthetic enamel black paint over a coat of red oxide zinc chrome primer to steel surfaces and including necessary earth work excavation in any type of soil etc., removal of surplus soil off the premises complete all as specified and as directed. |
| 30 | M&L for Construction of Valve Chamber of size 600mmx 600mmx 600mm (internal) internal size suitable for Sluice Valve, with 150 mm thick PCC 1:4:8, Type D2, using 40mm graded stone aggregate for foundation, 200 mm thick Brickwork with fly ash bricks using modular bricks in Cement Mortar 1:6, 40 mm thick PCC, 1:2:4, Type B1, using 20mm graded aggregate Coping, rendering in CM 1:4, 15 mm thick including provision of Mild Steel Sheet Cover 3 mm thick with 40 X 40 X 6 mm size Angle Iron frame work embedded in concrete with suitable hinges and locking arrangements including two coat of synthetic enamel black paint over a coat of red oxide zinc chrome primer to steel surfaces and including necessary earth work excavation in any type of soil etc., removal of surplus soil off the premises complete all as specified and as directed. |
| 31 | Supply and lay in roof / wall/ trench of PVC insulated, PVC sheathed multistranded copper cable 1100 volts grade of size 3 core 35 Sqmm in suitable size flexible PVC conduit complete all as specified and directed. |
| 32 | Supply and lay in roof/wall/trench of PVC insulated, PVC sheathed multistranded copper cable 1100 volts grade of size 3 core 10 Sqmm in suitable size flexible PVC conduit complete all as specified and directed. |
| 33 | Design, Supply, installing testing and commissioning factory fabricated Indoor type totally enclosed LT cubical panel board suitable size with suitable size busbar, conforming to relevant IS and protection class IP-56 ,dust, vermin and weather proof fabricated out of 2 mm thick CRCA sheet duly powder coated ,mounted on 50x50x6mm MS angle iron frame, duly welded in shape including necessary grouting of legs 300mm deep in ground in PCC 1:4:8 type D2 using 40mm graded stone aggregate ,panel base to be 500mm above ground level with suitable compartments for controls and Monitors including cable glands for incoming and outgoing cables, locking arrangement, including accommodating, supply and fixing the following accessories/items including necessary internal panel wiring with suitable size of Copper wire PVC insulated & sheathed multi stranded complete all as specified and as directed |
| 34 | (a) Adjustable thermal and magnetic settings MCCB TPN/4 pole 320-400 amps 50 KA 415 Volt, 50 Hz 01 Nos-1 No (Incoming)(b) Adjustable thermal and magnetic settings MCCB TP 250 amps 36 KA 415 Volt, 50 Hz D sines -03 Nos (outgoing)(c) MCCB TP 32 -40 amps 25 KA 415 Volt, 50 Hz -2 No (outgoing)(d) Star delta starter capacity for item no .01 with suitable range relay -03 Nos (e) Star delta starter capacity for item No.02 10 HP with suitable range relay- 02 Nos(f) MCB SPN 32 10 KA - 02 Nos (Outgoing)(g) Voltmeter & ammeter digital multifunctioning 0-500V-(Incoming & Outgoing) & DC connection (h) selector switch-(Manual, Auto mode & DC ON/OFF)(j) Indicating lamps (RYB) - & pump on and off for each pumps including standby pump (k) PCC Foundation (Civil works) for grouting of panel(l) Solenoid valve with pressure differential switch for automatic starting of jockey and main pumps. (m) Copper wiring & lugs suitable size for internal wiring (n) Bus Bar suitable size for RYBN(o) Motor protection relay suitable capacity. |
| 35 | Supply, installing, testing and commisioning, factory assembled silent diesel engine driven generator set, fully wired aleranator AC to give an output of 160kVA as per CPCB IV+ norms after derating factor, continuously rating at a power factor 0.8 lagging, 3-ph, 4 wire, 415 volts 50hz supply, 1500rpm directly coupled with diesel engine liquid cooled mounted on common base frame on ground with adequate capacity of fuel tank with fuel inline and accessories, fixing and aligning on ground with vibration pads, control panel and other accessories etc and comprising of following:-(i) Diesel Engine:- Liquid cooled turbo charged with after cooler to deliver suitble BHP after derating factor at 1500rpm under NTP (Normal Temperature and Pressure) conditions as per latest IS/SO with an overload capacity of 10% more for one hour in any 12hours continous operation with following acessories: Diesel engine of rated speed at full load electric start developing system with radiator, including electronic governer with latest class as per IS, engine control panel, lub oil pumping, water pumping (by gravity or external arrangement as recommended by OEM, fuel tank exhaust piping with silencer and suitable electric start with batteries of adequate capacity and rating of alternator of specified capacity complete with direct / flexible coupling and coupling guard complete. |
| 36 | (a) Radiator with blower fan or heat exchanger with guard.(b) Pipe coupling for engine cooling system piping.(c) Corrosion inhibitor coolant.(d) All type of filters as required and recommended by OEM (e) Fly wheel housing and fly wheel to be suit to the alternator (f) Shut off coil with safeties for LLOP (Low Lube Oil Pressure) /HWT (High Water Temperature) / over speed.(g) Engine bearing mechanisim in fly wheel housing.(h) Dry type air cleaners and vacuum indicators, silencers (k) Exhaust flexible bellows.(l) Battery charging alternator/DC dynamo.(m) First fill of oil, coolant and diesel during commissioning of and 12 hours testing.(n) Inter connecting all cables of adequate capacity batteries control and all pipelines.(o) Self starter 12 volts DC or as recommended by OEM of DG set.(p) Electric operated electronic governer with latest class as per IS.(q) Fuel injection pump/Pressure time pump as recommended by OEM of DG set.(r) No of cylinders as recommeded by OEM of DG set to acheive desired Outputof 160kVA after derating factor. |
| 37 | (s) providing all engine safety fatures like, water temp, engine temp, engine speed, lub oil pressure, frequency, voltage, safety control, lub oil temp, over speed stoppage(t) Adequate capacity of batteries for self starter .(ii) Fuel tank: Adequate storage capacity fuel tank with mounting brackets factory made of 5mm thick HR/MS sheet with level indicator fuel inlet, outlet, air vent, drain plug etc complete all as specified.(iii) Isolator panel with 250Amp MCCB, 35kA with tripping mechanisim(iv) Micro processor based Genset controller or Auto logical controlled Genset controller (as recommended by OEM of DG set) with monitoring features with display like voltage, currents, frequency, kVA, kW, kWH, kVarh, PF, Lub oil pressure, temparatures of engine, lub oil, water etc, RPM, run hours, No of starts, Fuel level, Auto/Manual start/stop, battery voltages and charge condtion, compitable AMF features and diagnostic features battery charging failures, over/under speeds, over/under voltages, over kW, Phase sequence, phase missing, mains under/over vlotage, earth falut trip, low fuel level, low oil pressure, high engine temparature, low/high battery voltage, over crank protection, routine maintenance indicator, gen set facility. |
| 38 | (v) Alternator: Suitable capacity Alternator for rated out put of 160 kVA capacity after derating factor, PF-0.8 lagging, 415volts, 3-ph, 4-wire, 50Hz at 1500rpm, self excited and self regulated with AVR brusheless, screen protected, drip proof, insulation of class-H, IP, voltage regulation grade latest, self ventilated confirming to lates BIS standards.(vi) Accoustic enclosure: M&L for above capacity DG set i.e 160kVA DG set to reduce noise level to 75dB measured at 1.0 meter distance as per guidelines CPCB IV+(vii) Base frame: Sturdy, fabricated welded construction, channel iron base frame(duly painted) for mounting of engine and alteranator i.e complete DG set as per manufacturer design along with AVM pads, other necessary accessories complete as required.AMF/ATS:Supply install ,testing and commissioning of enclosed Auto transfer switch Frame 3, 250A,Adjustable Time Delay (0.1sec to 3 hours), Suitable for 3-Phase Double-Break Contact System offering High Protections: UV/OV, Phase Sequence including necessary cable end terminations including necessary wiring etc complete all as specified and directed. Please Enable Macros to View BoQ information |