| 1 | Dismantling of floor hearth/wall tiles including cement mortar bedding (but not backing) and removing serviceable tiles, complete all as specified and directed. |
| 2 | M&L for Non skid coloured ceramic tiles 7 to 8 mm thick, area of each tiles exceeding 0.06 sqm but not exceeding 0.11 sqm as in floors including 15mm thick screed bed or bedding layer in CM (1:6) set and jointed in neat cement slurry and pointed in coloured cement to match, complete all as specified and directed. |
| 3 | M&L Glazed ceramic tiles in vertical surface 600x300x7 / 450x 300x 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade including 10mm thick rendering coat in CM 1:4 with 6 mm spacer filled with epoxy grout, complete all as specified and directed. |
| 4 | M&L for ceramic tiles 7-8 mm thick, area of each tiles exceeding 0.18 sqm but not exceeding 0.38 sqm as in floors including 15mm thick screed bed or bedding layer in CM (1:6) set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles, complete all as specified and directed by Engr in charge. |
| 5 | M&L for ceramic tiles 7-8 mm thick, area of each tiles exceeding 0.18 sqm but not exceeding 0.38 sqm as in vertical surface including 15mm thick screed bed or bedding layer in CM (1:6) set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles, complete all as specified and directed by Engr in charge. |
| 6 | Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc, complete all as specified and directed. |
| 7 | M&L Granite (of any type and size) 18-20mm thick machine cut bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone over 15mm thick screed bed in CM 1:6 on kitchen platform, Cill of Window/Ventilator/ flooring/border etc including rubbing, grinding and polishing, complete all as specified and directed. |
| 8 | Material and labour 20-25mm thick machine cut cudappa stone slab in horizental/vertical jams laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing polishing & rounding to edges of slab as in window cills/jams including screed bedding 10mm thick in CM 1:6, complete all as specified and directed. |
| 9 | Demolition of cement concrete (un-reinforced) in of any description and in any position not otherwise specifically provided, complete all as specified and directed. |
| 10 | M & L Hardcore of guage exc 63mm but n exc. 100mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface, complete all as specified and directed. |
| 11 | M&L for 75 mm thick plain cement concrete 1:4:8 type D-2 (using 40mm graded aggregate) as in sub base & similar work including necessary expansion joint filling with bitumen at a certain distance, complete all as specified and directed. |
| 12 | M&L for PCC type B-1 1:2:4 (20 mm graded stone aggregate) finishing even and rough to receive the tiles, complete all as specified and directed. |
| 13 | M&L for PCC 1:3:6 type C-1 using (20mm graded stone aggregate) as in bed blocks for hold fast, complete all as specified and directed. |
| 14 | Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including snap grid frame work, complete all as specified and directed. |
| 15 | M&L for E-board tiles ceiling on GI powder coated channel/Tee/Grid frame work with the following specification including cutting holes in brick wall built in cement mortar & making good in cement concrete 1:2:4 type B-0/Cement mortar 1:3 complete all as specified and directed with following:- (a) M&L Plugging to wall around the rooms & supplying & fixing GI powder coated angle of size 25 x 25 mm. (b) S&F 1mm dia GI wire suspenders including fixing to ceiling. (c) S&F GI powder coated tee as in main & cross members at 595 mm centre to centre supported suspenders along with adjustable camp to maintain level. (d) S&F for E-board ceiling tilesof size 595 mm x 595 mm x 4 mm thickness, confirming to relevant IS in squares of GI powder coated tee with clips made to shape, shade and pattern of tiles shall be as approved by GE. |
| 16 | S&F in repairs 18mm thick Both Side pre laminated HDHMR Board of any colour, Matt surface finish, grade I as per IS 14587, for frame and shutter for kitchen cabinets/ vanity complete with all necessary fittings like ss hinges, brass, handles and magnets, complete all as specified and directed. |
| 17 | M&L Solid PVC Wall Lining consisting of 5mm thick Wood grain printed PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing, complete all as specified and directed by Engr in Charge. |
| 18 | M&L 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing, complete all as specified and directed. |
| 19 | Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings including ridges, complete all as specified and directed. |
| 20 | Dismantling timber scantlings 40 Sqcm and over in section, in unframed work in any position, complete all as specified and directed. |
| 21 | Dismantling of wrought iron or mild steel work in framed trusses not exc 10 m span, complete all as specified and directed. |
| 22 | S&F for Rolled mild steel sections conforming to Gde Fe-290 (Gde-165-E) as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails & guides for sliding doors, fixed with angle cleats or other connecting plates, complete all as specified and directed. |
| 23 | S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed by Engr in Charge. |
| 24 | All as per item No. 23 above but except sheet. |
| 25 | M&L for preparation of new untreated steel surface of any description exc 10cm width or girth applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and as directed. |
| 26 | S&F Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed by Engr in Charge. |
| 27 | Demolition of brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles including removing debris out side MD land, complete all as specified and directed. |
| 28 | Material and Labour for Brick work with sub class 'B' brick straight or curved on plan exc 6 mtr mean raddius built in CM 1:6, complete all as specified and directed. |
| 29 | Material and Labour for Brick work with sub class 'B' brick straight or curved on plan in any raddius in half brick thick walls built in CM 1:6, complete all as specified and directed. |
| 30 | Taking down cement plaster on brick/stone or concrete surface including racking out joints, hacking for key, scrubbing down with water to receive plaster, including removing debris/rubbish materials off the site out side MD land, complete all as specified and directed. |
| 31 | Demolition of reinforced cement concrete (reinforced cut as required to facilotate demolition) in any position (Beam, landing Chajja and Roof slab etc) ground floor/ other than ground floor, projection of balcony complete, complete all as specified and directed. |
| 32 | M&L RCC M-25 Design Mix (using 20mm graded aggregate)as in Beams, cantilevers, bressummers, lintels over 1.50 m span supported on walls, complete all as specified and directed. |
| 33 | Providing and fixing special water tight centering and shuttering including bolting, strutting, propping etc. so as to withstand a pressure of 0.1 Mpa including removal of form from all locations including beams, columns, slabs, walls, foundations, footings, landings, stairs, balconies etc, complete all as specified and directed. Please Enable Macros to View BoQ information |
| 34 | Providing and fixing special water tight centering and shuttering including bolting, strutting, propping etc. so as to withstand a pressure of 0.1 Mpa including removal of form from all locations including beams, columns, slabs, walls, foundations, footings, landings, stairs, balconies etc, complete all as specified and directed. Please Enable Macros to View BoQ information |