| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / heavy class PVC conduit with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.(Make of switches: Legrand Lyncus, L&T Entice, Anchor Roma Classic, Panasonic Akina, Crabtree Athena, ABB Adiva, Schneider Electric Clipsal) (Make of wire : Finolex,Anchor,Polycab,Plaza)Make of conduit;- Diplast/BEC/AKG) as approved by Engineer-In-Charge |
| 2 | Group C |
| 3 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / heavy class PVC conduit , 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.FRLS PVC insulated copper conductor single core cable etc as required.(Make of switches: Legrand Lyncus, L&T Entice, Anchor Roma Classic, Panasonic Akina, Crabtree Athena, ABB Adiva, Schneider Electric Clipsal) (Make of wire : Finolex,Anchor,Polycab,Plaza)Make of conduit;- Diplast/BEC/AKG) as approved by Engineer-In-Charge |
| 4 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed heavy class PVC conduit as required Make:-Finolex,Anchor,Polycab,Plaza as approved by Er-In-Charge |
| 5 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 6 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 7 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 8 | 2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 9 | 4 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 10 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.Make:-Finolex,Anchor,Polycab,Plaza as approved by Engineer-in -charge. |
| 11 | 3 x 1.5 sq. mm |
| 12 | 3 x 2.5 sq. mm |
| 13 | 3 x 4 sq. mm |
| 14 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required(Make of switches: Legrand Lyncus, L&T Entice, Anchor Roma Classic, Panasonic Akina, Crabtree Athena, ABB Adiva, Schneider Electric Clipsal)as approved by Engineer-In-Charge |
| 15 | 5/6 amp Modular switch |
| 16 | 5 pin 5/6 amp socket outlet |
| 17 | Telephone socket outlet |
| 18 | modular blanking plate |
| 19 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 5 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.(Make of switches: Legrand Lyncus, L&T Entice, Anchor Roma Classic, Panasonic Akina, Crabtree Athena, ABB Adiva, Schneider Electric Clipsal)as approved by Engineer-In-Charge |
| 20 | Supplying and fixing suitable size GI box with modular plate and cover in FRLSont on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.(Make of switches: Legrand Lyncus, L&T Entice, Anchor Roma Classic, Panasonic Akina, Crabtree Athena, ABB Adiva, Schneider Electric Clipsal)as approved by Engineer-In-Charge |
| 21 | Supplying & fixing suitable size GI box wih modular plate and cover in front onsurface or in recess i/c providing and fixing 32 amp modular socket outlet and 25Amps modular SP MCB, “C” curve including connection, painting etc. as required.(Make of switches: Legrand Lyncus, L&T Entice, Anchor Roma Classic, Panasonic Akina, Crabtree Athena, ABB Adiva, Schneider Electric Clipsal)as approved by Engineer-In-Charge |
| 22 | Supplying and fixing Computer board comprising 3 nos 5 amp modular switches & Sockets , G.I box 2 module for jack box and G.I Box 12 module for 5 amp switchs and 5 amp sockets comprising sheet cover for each 2 module metal box , one no computer jack (RJ-45)with shutter including connections etc as required.Make :-Anchor (Roma classic ),L&T(Entice),Legrand(Myrius) as approved by Er-In-Charge |
| 23 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/recessed steel/ PVC conduit including conections,as required. |
| 24 | Supplying and fixing D- link DGS-1008 A 8-port 10/100/1000Mbps Unmanaged standalone gigabit switch in desk top (green ethernet) for getting blazing speed of giga bite that delivers power performance and reliability i.e increasing the speed of net work server in large in switching protocol storing and forwarding as required .Make:- D-Link(Code No DGS-1008A) Digilink, Cisco/ as approved by Engineer-in-Charge. |
| 25 | Supplying and fixing Loaded Wall- Wall Mount 2u Dimensions 44 X57 X20 CM Front Glass Door(tinted,toughened) with LOCK &KEY, 2PAIRS OF I9\\" Mounting Rail with U-Marking welded Side walls !U Cable Manager (1) Hardware Packet (1Pkt)3 socket 5amp .power distribution Unit(1NO) .Make:- D-Link Cisco, Digi link as approved by Er-In-Charge |
| 26 | Supplying and fixing of following sizes of heavy class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.Make Diplast/BEC/AKG as approved by Engineer-in -charge. |
| 27 | 25 mm |
| 28 | Providing and installation exhaust fan metal body of 300 mm light duty in the existing opening,including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required: Make : (Usha Aeroclean LD, Orient Air Flow, Crompton Drift Air Plus Metal Anti Dust, Anchor Anmol Deluxe-R, Havells Ventil Air DS Only)as approved by Engineer-In-Charge ( Five year warranty) |
| 29 | Supplying and fixing exhaust fan louver shutter for 300 mm.exhaust fan on the existing wall,painting etc, as required, |
| 30 | Supplying and fixing Ding Dong call bell suitable for single phase, 230 V, complete as requiredMake :-Anchor (Roma classic ),L&T(Entice),Legrand(Myrius) as approved by Engineer-in -charge. |
| 31 | Providing, Installation, testing and commissioning of BLDC ceiling fan (5 star rating), with socket type 2 module fan regulator including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mm twin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required: (Make: Usha Technix BLDC ISI, Orient Echotech Prime, Havells Efficiencia, Bajaj Energos 26, Anchor Ecobreez Urban 3 Blades, Crompton Energion HS Groove Hyperjet only)as approved by Engineer-In-Charge ( Five year warranty) |
| 32 | Ceiling Fan 1200 mm sweep |
| 33 | Supplying and fixing of LED downlighter of following watts surrface/Recess Mounted Downlighter Round Shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Housing and HET diffuser and P.F.>0.95 ,THD<10% ,CCT 5700k/4000K, CRI 80, IP20 optical compartement.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V .Fixture have Surge Protection 2kV .Driver complete with all accessories, connections, testing and commissioning etc. Make:- Philips/wipro/ LT as approved by Engineer-in-Charge( Five year warranty) |
| 34 | Providing and Fixing of LED fixture 600mmX600mm 36 Watt +/- 1W Recess /Surface mounted fixture with HET Plastic diffuser with minimum system lumen efficacy of 100 lm/W with CRCA housing having P.F.>0.95 with THD<10% ,CRI 80.The LED with Useful life of 50000 Hrs at L70. The LEDs used in the luminaire shall have CCT of 5700 K with CRI of minimum 80. The Input voltage range shall be 150V to 270V, 50/60 HZ complete with all accessories, including connections, testing and commissioning etc.as required complete in all respects.Make:- Philips/wipro/ LT as approved by Engineer-in-Charge( Five year warranty) |
| 35 | Providing and fixing of surface mounted Luminaire LED batten 10 watts ,having high Quality design aluminium extruded decorative end caps and it should be compatible with specification i.e. P.F >.9,THD<10% and luminius flux 1100 Lumens per watt 110,CRI> 80 suitable for input voltage: AC 220-240 V, 50/60Hz, Burning hours >50000@L70 complete with all accessories, connections, testing and commissioning etc as:Make:- Philips/wipro/ LT as approved by Engineer-in-Charge( Five year warranty) |
| 36 | Providing and fixing of following type surface mounted Luminaire LED batten 25 watts ,having high Quality design aluminium extruded decorative end caps and it should be compatible with specification i.e. P.F >.9,THD<10% and luminius flux 3250 Lumens per watt 130,CRI> 80 suitable for input voltage: AC 220-240 V, 50/60Hz, Burning hours >50000@L70 complete with all accessories, connections, testing and commissioning etc as:Make:- Philips/wipro/ LT as approved by Engineer-in-Charge( Five year warranty) |
| 37 | Providing and fixing of IP40 Led fixture 40 W+/- 1W with Surface Mounted 4 Feet with specifically designed for low temperature application from -20deg to +45deg C. IP66. Burning hours >50000@L70 complete with all accessories, connections, testing and commissioning etc as:)Make:- Philips/wipro/ LT as approved by Engineer-in-Charge( Five year warranty) |
| 38 | Providing and fixing of of IP40 Led fixture 40 W+/- 1W with Surface Mounted 4 Feet with Polycarbonate diffuser with aluminium housing having minimum system lumen efficacy of 125 lm/W with minimum system lumen output 5000 lumens with P.F.>0.95 with THD<10% ,CCT 5700K, CRI 80,Surge Protection 3 Kv .The LEDs with minimum life of 50000 burning hours. The Input voltage range shall be150V to 270V. complete with all accessories, connections, testing and commissioning etc as:)Make:- Philips/wipro/ LT as approved by Engineer-in-Charge( Five year warranty) |
| 39 | Supplying and fixing of DLP 105x50 mm PVC adaptable trunking on the exiting wall at required height from lower level for power connection, light connection and net working connection including partition chip flexible cover end cap .Make:-Legrand ,MK ,SIEMENS as approved by Er-in-charge |
| 40 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. |
| 41 | Supplying and laying 6 SWG G.I. wire at 0.50 Meter below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 42 | Supplying Installaion Testing & commissiong of copper strip bus-bars in existing cubicle panel board suitable for 200 Amp. 415 volts capacity 4 No. each of cross-sectional area (16mmx3.17mm),in the existing enclosure with all accessories including connections etc. as requiredMake L&T, Legrand ABB as approved by Engineer-in -charge. |
| 43 | Supplying and erection of following depth Indoor cubical panel, as per the standards IEC 61439-1&2 as tested assembly, IP 42 fabricated CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland plates i/c cleaning& finishing complete with 7 tank process powder coating in approved shade,, DMC/ SMC bus bar supports,bottom base channel of MS section not lessthan100 mmx 50 mmx 5 mm thick, fabrication shall be done in transportable sections, form of separation shall be form 4b with metallic separation only,the same shall be erected in the 1:2:4 cement concrete plat-form of suitable dimensions 15 cm high from ground level, thick.The size of control wiring in cubical panel FR-LSH 1.5 sqmm.The panel should be approved /Tested from the CPRI lab. make of switcgear L&T, Schneider,ABB as approved by Engineer-in -charge.( Five year warranty) |
| 44 | 300 mm Deep |
| 45 | Supplying Installaion Testing & commissiong of MCCB 125 Amp rating and 25 kA breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as requiredMake L&T, Schneider,ABB as approved by Engineer-in -charge.( Five year warranty) |
| 46 | Supplying Installaion Testing & commissiong of indicator set RY&B in existing cubicle panel board with 3 Nos Kit kat (LED type) to shown the three indicating in the existing pannel complete etc as required.Make L&T, Schneider,ABB as approved by Engineer-in -charge. |
| 47 | Supplying Installaion Testing & commissiong of Multi Function Meter in existing cubical panel board with 3 Nos. Cast Resin CTs and MCBs including V, A ,F ,P.F, KW, KVA, RUN HOUR,KWH,(EV AND DG), OLD ENERGY, SELECTATBLE KWH-KVH parameters connections , testing, commissioning etc. as requiredMake:- L&T/ Legrand, Hager, ABB as approved by Er-In-Charge (five year warranty) |
| 48 | Providing and fixing 125 AMP , four pole, 415 volts, On-Load change over switch in open execution , front handle operation, including making connections, etc. as required. Make:- L&T ,Legrand,Hager as approved by Engineer-in -charge. |
| 49 | Supplying Installaion Testing & commissiong of Digital Voltage monitoring relay in existing cubicle panel board includes single phase preventor, selectable under voltage + over voltage , neutral loss time delay power on delay (0 to 999 sec) off delay ( 0.1 to 999 sec & on delay (0.5 to 999 sec), Asymmetry voltage 5 to 99 vac (default 60 v )percentage 2 to 50 % (Default 10%) etc, complete in all respect connections , testing, commissioning etc. as required Make:- L&T, Legrand, Hager, ABB as approved by Er-In-Charge (five year warranty) |
| 50 | Supplying and fixing of Segregated tripple pole and neutral 6 ways surface/ recess mounting, 7 Segment 415volts, TPN MCB distribution board of sheet steel, dust protected, dulypowder painted, with provision to mount FP-MCB incomer, DP MCB/RCCB sub-incomer ineach phase and SP MCBs as outgoing (but without MCB ’s and incomer),complete with tinned copper din-bar, wire-set, neutral link, earth bar, detachablegland plate, cable interconnections, including earthing etc. as required:- Make L&T, Schneider,ABB as approved by Engineer-in -charge.( Five year warranty) |
| 51 | Supplying Installaion Testing & commissiong of following way, single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/recess, complete with tinned copper bus bar, neutral busbar, earth bar,din bar,interconnections, powder paintedincluding earthing etc. as required. (But withoutMCB/RCCB/Isolator)Make L&T, Schneider,ABB as approved by Engineer-in -charge.( Five year warranty) |
| 52 | MCBDB 12 WAY Double Door |
| 53 | Supplying Installaion Testing & commissiong of 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.)Make L&T/ Schneider/ABB as approved by Engineer-in -charge.( Five year warranty) |
| 54 | Single pole |
| 55 | Supplying Installaion Testing & commissiong of 40/50/63 amps rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of pole Double pole in the existing MCB DB complete with connections etc. as required:-Make L&T/ Schneider/ABB as approved by Engineer-in -charge.( Five year warranty) |
| 56 | Supplying Installaion Testing & commissiong of 63 amps rating, 240/415 volts, 10 kA, “C” curve,miniature circuit breaker suitable for inductive load of four poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.:-Make L&T/ Schneider/ABB as approved by Engineer-in -charge.( Five year warranty) |
| 57 | Supplying Installaion Testing & commissiong of following rating, double pole, (single phase and neutral), 240 volts,10 kA breaking capacity residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.-Make L&T/ Schneider/ABB as approved by Engineer-in -charge.( Five year warranty) |
| 58 | 40 AMP |
| 59 | 63 AMP |
| 60 | Supplying installation testing & comminssiong of 20Watt Solar Light as per MNRE with MPPT Controller 12V DC, Semi Integrated Light with Inbuilt battery-1Nos b) Solar Module 120W BIS approved -1Nos c) LFP Battery 48Ah 12.8V BIS Approved-1Nos d) 5Mtr HDG Octagonal Pole with all accessories for Solar, OD-70/130mm Thick-3mm, Base plate-220x220x12mm, J-Bolts M16x450mm -1Set complete in all respect as required.Warranty-5Yrs for Complete System BIS approved make |
| 61 | Supplying Installaion Testing & commissiong of stationary storage type Electric water heater (Geyser) with temperature Knob control various sizes by means of expansion-bolts with nuts and washers, including embedding of expansion-bolts in the wall, making good the damages, electrical connections, testing etc. complete as required:- -Make:-Usha/ Bajaj/ Recold as approved by Engineer-in -charge.( Five year warranty) |
| 62 | 10 litre |
| 63 | 25 litre |
| 64 | Supplying, installation, Testing & Commissioning of 5 KVA/4.4 KW capacity at full load (Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input, Single Phase output AC Supply. The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch along with provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. The UPS systems shall be Microprocessor based Digital Control, using Insulated Gate Bipolar Transistor (IGBT)'s both for the rectifier & inverter with PWM (Pulse Width Modulation) Technology. The quality of design, manufacturing and inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be >95% at 100% non-linear loads. Current total harmonic distortion(ITHD)/ total demand distortion (TDD) on the input grid shall be < 5% at 100 %load. (The required LC filters shall be includedin UPS cost), extreme power factor kit to be include to limit the input pf to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ) however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC single phase 160-270V 50 Hz and delivering output AC supply true sine wave single phase 220/230/240 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins and 150% for 1 minute.Operatingtemperature 0 to 40 0C, Relative humidity 0-95% non condensing, noise level less than 60db at 1 meter distance, Protection for Under voltage, over voltage, abnormal output voltage, battery over charging, output over current, short circuit, battery deep discharge , 10 KV surge. Display for watt/VA,Amp and Voltage power parameters etc. UPS shall comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI) type UPS (as per standard IEC 62040-1, 2 & 3) . The UPS should be with IGBT Based Inverter Technology, Communication RS232/ RS485/ SNMP port open protocol for BMS integration as per approved by Engineering in charge. Required battery racks, DC breaker of suitable rating and interconnecting copper conductor cable of suitable size and connectors and all required accessories are inclusive in the cost. The UPS should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc Along with onsite installation & 5 years warranty on UPS & 3 years on batteries. Here one set comprising of one nos 5 KVA UPS with battery bank, as per detailed specifications enclosed, as reqd. Make : APC-Schneider/ Legrand-Numeric / Emerson-Vertiv/Microtek for UPS & Exide/Amaron-Quanta/Panasonic/ Make for SMF Batteries(Performance Comply to IEC 62040-3) .( NOTE . The Contractor shall be carried out one service quartly during five year by authurised OEM ,Also if any breakdown occure during warranty period the contractor shall be rectify within 24 hour/minimum time period.) |
| 65 | Providing, laying and fixing of one No. aluminium conductor,of following size confirms to IS 7098(part-1) PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade on surface including lugs & gland complete in Conections testing & commissiong etc. as required .Make:Finolex ,plaza, polycab,havells as per approved by Engineer-in -charge. |
| 66 | Armoured cable 50 sqmm(3.5 core) Please Enable Macros to View BoQ information |