| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Make:- Anchor (Roma classic )/ L&T(Entice)/ Legrand (Myrius) as approved by Engineer-In-Charge. |
| 2 | Group - C |
| 3 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Make:- Anchor (Roma classic )/ L&T (Entice)/ Legrand(Myrius) as approved by Engineer-In-Charge. |
| 4 | Group - C |
| 5 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulatedcopper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as required. Make:- Anchor (Roma classic )/ L&T(Entice), Legrand(Myrius) as approved by Er-In-Charge. |
| 6 | Supplying and fixing following rating Modular switch /socket on the existing switch box / cover plate including connections but excluding modular plate etc. as required. Make:- Legrand(Myrius)/ L&T(entice/, Anchor (Roma Clasic ) as approved by Engineer-in -charge . |
| 7 | S.P. 5/ 6 Amps one way Modular switch. |
| 8 | 5 pin, 5/ 6 Amps Modular socket outlet. |
| 9 | Supplying and fixing RJ 45 JACK including connections but excluding modular plate etc. as required. Make:- Legrand(Myrius)/ L&T(entice)/ Anchor (Roma Clasic ) as approved by Engineer-in -charge . |
| 10 | Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps, modular switch, connections etc. as required. Make:- Legrand(Myrius)/ L&T(entice) / Anchor (Roma classic ) as approved by Engineer-in -charge . |
| 11 | Supplying and fixing suitable G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 amps & 15/16 amp modular socket outlet and 15/16 amps, modular switch, connections etc. as required. Make:-Legrand(Myrius)/ L&T (entice)/ Anchor (Roma classic ) as approved by Engineer-in -charge . |
| 12 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 amps modular socket outlets and 2 nos 5/6 amps modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).Make:-Legrand(Myrius)/ L&T(entice)/ Anchor (Roma classic ) as approved by Engineer-in -charge . |
| 13 | Supplying and fixing Computer board comprising 3 nos 5 amp modular switches & Sockets , G.I box 2 module for jack box and G.I Box 12 module for 5 amp switchs and 5 amp sockets comprising frame and cover plate for each 2 module metal box and 12 module metal box , one no computer jack (RJ-45)with shutter including connections etc as required.Make:- Legrand(Myrius)/ L&T(entice)/ Anchor (Roma classic ) as approved by Engineer-in -charge . |
| 14 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required |
| 15 | Supplying and fixing following size/modules,G.I box alongwith modular base & cover for modular switches in recess etc.as required. Make:-Legrand(Myrius), L&T(entice), Anchor (Roma classic ) as approved by Engineer-in -charge . |
| 16 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess i/c providing and fixing 25 amp modular socket outlet and 25Amps modular SP MCB, “C” curve including connection, painting etc. as required. Make:-Legrand(Myrius)/ L&T(entice)/ Anchor (Roma classic ) as approved by Engineer-in -charge . |
| 17 | Wiring for circuit/sub-main wiring along with earth wire with following size of FRLS PVC insulated copper conductor single core cable in surface/recessed steel conduit as required. Make:-Plaza/ Anchor/ Polycab/ Finolex as approved by Engineer -in -charge . |
| 18 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 19 | 2 x 4 Sq. mm.+ 1X4 sq.mm earth wire |
| 20 | 2x10 Sq. mm.+ 1X6 sq.mm earth wire |
| 21 | 4x6 Sq. mm.+ 2X6 sq.mm earth wire |
| 22 | 4x10 Sq. mm.+ 2X6 sq.mm earth wire |
| 23 | Supplying and drawing following size of FRLS PVC insulated copper conductor single core cable in existing surface / recessed, Steel/medium class PVC conduit as required. Make:- Plaza/ Anchor/ Polycab/ Finolex as approved by Engineer -in -charge. |
| 24 | 3x1.5 Sq. mm. |
| 25 | 3x4.0 Sq. mm. |
| 26 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/recessed steel/ PVC conduit as required. |
| 27 | Supplying and fixing of following sizes of PVC conduit Heavy duty ISI marked minimum thickness 2.0 mm along with accessories insurface/recess including painting in case of surface conduit, or cutting the walland making good the same in case of recessed conduit as required. Make:-Diplast/BEC/Polyfit as approved by Engineer-in -charge. |
| 28 | 25 mm. dia |
| 29 | 40 mm. dia |
| 30 | Supply and fixing of backlit non slim surface/recess LED downlighter in 12 W +/- 1 W in SQ/round Shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium heat sink and HET diffuser and polycarbonate mounting box P.F.>0.95 ,THD<10% ,CCT 5700K/4000K, CRI 80, UGR<23,IP20 protection. The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V .Fixture have Surge Protection 3kV, Driver. Make -WIPRO/PHILIPS/LEKSA/LT as approved by Engineer-in-Charge with five year warranty. |
| 31 | Supply and fixing of backlit non slim surface/recess LED downlighter in 15 W +/- 1 W in SQ/Round Shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium heat sink and HET diffuser and polycarbonate mounting box P.F.>0.95 ,THD<10% ,CCT 5700K/4000K, CRI 80, UGR<23,IP20 protection.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V. Fixture have Surge Protection 3kV, Driver. Make -WIPRO/PHILIPS/LEKSA/LT as approved by Engineer-in-Charge with five year warranty. |
| 32 | Supply and fixing of backlit non slim surface/recess led downlighter in 18 W +/- 1 W in Square/ Round Shape with with minimum system lumen efficacy of 110 lm/W with Pressure Die cast Aluminium heat sink and HET diffuser and polycarbonate mounting box P.F.>0.95 ,THD<10% ,CCT 6000K, CRI 80, UGR<23,IP20 protection.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V. Fixture have Surge Protection 3kV, Driver. Make -WIPRO/PHILIPS/LEKSA/LT as approved by Engineer-in-Charge with five year warranty. |
| 33 | Supply and fixing of backlit non slim surface/recess LED downlighter in 24 W +/- 1 W in square Shape/round with minimum system lumen efficacy of 110 lm/W with Pressure Die cast Aluminium heat sink with and HET diffuser and polycarbonate mounting box P.F.>0.95 ,THD<10% ,CCT 6000K, CRI 80, UGR<23,IP20 protection.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V .Fixture have Surge Protection 2.5kV .Driver Make -WIPRO/PHILIPS/LEKSA/LT as approved by Engineer-in-Charge with five year warranty. |
| 34 | Supply and fixing of backlit non slim recessed adjustable LED downlighter in 32 W +/- 1 W in square Shape/round with minimum system lumen efficacy of 110 lm/W with Pressure Die cast Aluminium heat sink with and HET diffuser and polycarbonate mounting box P.F.>0.95 ,THD<10% ,CCT 6000K, CRI 80, UGR<23,IP20 protection.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V .Fixture have Surge Protection 2.5kV .Driver Make -WIPRO/PHILIPS/LEKSA/LT as approved by Engineer-in-Charge with five year warranty. |
| 35 | Supply and fixing of 2X2 Led fixture OPUS 34 W +/- 1W recessed direct indirect mounted fixture with HET Plastic diffuser with CRCA Powder Coated housing having efficacy 100lm/W with P.F.>0.95 with THD<10%. The LED with Useful life of 50000 Hrs at L70. The LEDs used in the luminaire shall have CCT of 5000K- 5700 K with CRI of minimum 80. The Input voltage range shall be 150V to 270V .Fixture have Surge Protection 2kV. Driver Output voltage shall be less than SELV Limits for safe operation and maintenance. Make -WIPRO/PHILIPS/LEKSA/LT as approved by Engineer-in-Charge with five year warranty. |
| 36 | Supply and fixing of Led fixture 4Ftx1Ft 36 W+/- 1W Surface/ recess mounted Mounted with HET plastic diffuser with CRCA powder coated housing having efficacy of 100 lm/W with P.F.>0.95,THD<10%. The LED with useful life of 5000 hrs at L70. The LED used in the luminaire shall have CCT of 5000-5700K with CRI of minimum 80. The input voltage range shall be 150V-270V. Fixture have surge protection 2KV. Driver output voltage shall be less than SELV limits for safe operation and maintenance complete with all accessories, connections, testing and commissioning etc.as required Make -WIPRO/PHILIPS/LEKSA/LT as approved by Engineer-in-Charge with five year warranty. |
| 37 | Supply and fixing of IP20 Led fixture 2FT 10 W+/- 1W with Surface Mounted 2 Feet with aluminium housing and Polycarbonate diffuser,minimum system efficacy of 100 lm/W with P.F.>0.95 with THD<20% ,CCT6500 K,CRI 80,Surge Protection 2 Kv, IP20. The LED with Useful life of 50000 Hrs at L70. The Input voltage range shall be 150V to 270V,complete with all accessories, connections, testing and commissioning etc.as required. Make -WIPRO/PHILIPS/LEKSA/LT as approved by Engineer-in-Charge with five year warranty. |
| 38 | Providing, Installation, testing and commissioning of BLDC ceiling fan1200 mm without socket type regulator,including wiring the down rods of standard length (up to 40 cm) with 16/0.20 mmtwin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required. Five star rating Make:- Usha (Technoaire BLDC without remote)/Orient/Crompton as approved by Engineer-in-charge with Five Year Warranty. |
| 39 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.Make:- Anchor (Roma classic )/ L&T(Entice)/ Legrand(Myrius) as approved by Engineer-In-Charge. |
| 40 | Providing and Installation of 450 mm pedestal fan metal body on floor mounting base with heavy duty motor,connections,testing and commissioning etc.as required with five year warranty. Make:- Orient/ Usha/Crompton as per satisafaction of Engineer-in-Charge. |
| 41 | Providing and Installation of 600 mm air circulator metal body on wall with heavy duty motor i/e hang the same in position on the wall,connections,testing and commissioning etc.as requiredwith five year warranty. Make:- Orient/Usha/Crompton as per satisafaction of Engineer-in-charge. |
| 42 | Providing and installation of stationary storage type Electric water heater (Geyser) of 10 Ltrs by means of expansion-bolts with nuts and washers, includingembedding of expansion-bolts in the wall, making good the damages, electricalconnections, testing etc. complete as required. Make:- Usha (Model 10 L SWH MISTY WITH KIT)/ Bajaj/ Recold not less than 5 star rating as approved by Engineer-in-charge with Five year Warranty . |
| 43 | Providing and installation exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required with five tear warranty. Make:- Usha (Aeroclean-LD metal body&GBD)/Orient/Crompton as approved by Engineer-in-charge with Five year warranty. |
| 44 | Providing and installation exhaust fan of 450 mm (H.D) in the existing opening,including making the hole to suit the size of the above fan, making good thedamages, connections, testing and commissioning etc. as required: Make:- Usha (TURBO H.D. 900 RPM )/ Orient/ Crompton as approved by Engineer-in-charge with Five year warranty. |
| 45 | Providing and installation exhaust fan of 300mm (Plastic body) size in the existing opening,including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required: Make:- Usha/Orient/Crompton as approved by Engineer-in-charge with five year warranty. |
| 46 | Supplying and fixing Loaded Wall- Wall Mount 2u DVR wall rack 2U-400D ,Unloaded Mounting Rail with U-Marking welded Side walls !U Cable Manager (1) Hardware Packet (1Pkt) 3 socket 5amp .power distribution Unit(1NO) .Make:- D-Link( CAT NO NWR-2U-5540-GR- DVR)/Cisco/ Digi link as approved by Engineer-in-Charge. |
| 47 | Supplying and fixing 8-port 10/100/1000Mbps Unmanaged standalone gigabit switch in desk top (green ethernet) for getting blazing speed of giga bite that delivers power performance and reliability i.e increasing the speed of net work server in large in switching protocol storing and forwarding as required .Make:- D-Link(Code No DGS-1008A) Digilink/ Cisco/ as approved by Engineer-in-Charge. |
| 48 | Supplying and erection of 5 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:Make L&T/Legrand/Hager/ ABB as approved by Engineer-in -charge. |
| 49 | Single pole |
| 50 | Supplying and erection of MCB DP 40/50/63 amps rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required. Make:- L&T/ Legrand/Hager/ ABB as approved by Engineer-in -charge. |
| 51 | Double pole |
| 52 | Supplying and fixing following rating, 10 KA double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 30 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make:- L&T/ Legrand/Hager/ ABB as approved by Engineer-in -charge. |
| 53 | 40 Amps. |
| 54 | Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, neutral bus bar, earth bar, din-bar, interconnections, and powder painted, including earthing etc. as required. ( but without MCB/RCCB/Isolator) Make:- L&T/ Legrand/ Hager/ ABB as approved by Engineer-in -charge. |
| 55 | Double door-4 way |
| 56 | Double door-12 way |
| 57 | Supplying and fixing 6 to 32 amps rating, 240/415 volts, 10 kA, “C” curve,miniature circuit breaker suitable for inductive load of four poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make:- L&T/ Legrand/Hager/ ABB as approved by Engineer-in -charge. |
| 58 | Supplying and fixing of Segregated tripple pole and neutral 8 ways surface/ recess mounting, 7 Segment 415volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, with provision to mount MCCB incomer, DP MCB/RCCB sub-incomer ineach phase and SP MCBs as outgoing (but without MCB ’s and incomer),complete with tinned copper din-bar, wire-set, neutral link, earth bar, detachablegland plate, cable interconnections, including earthing etc. as required:- Make:- L&T/ Legrand/ Hager/ ABB as approved by Engineer-in -charge. |
| 59 | Supplying and erection of following depth sheet metal cubical pedestal of suitable dimensions with plus-minus 5 cm variation, made from 1.6 mm thick M.S. sheet duly fabricated in a segregated manner for housing of switch fuse units, by welding each compartment on five sides & front side hinged, complete with locking arrangement, with sufficient No. vertical and horizontal intermediate switchgear housing compartments. The cubical pedestal shall have cable entry box at one or two sides, with epoxy powder coated approved paint and bonding to the existing earth etc. The same shall be erected in the 1:2:4 cement concrete plat-form of suitable dimensions 15 cm high from ground level and 45 cm thick. The cubical pedestal shall be 15 cm from the top of cement concrete plat-form.The panel should be approved /tested from the CPRI Lab & should confirmed to IEC-61439 (Part-I&II) Make:- Power system & Controls/L&T/KSB as approved by Engineer-in -charge. |
| 60 | 300 mm deep (nominal) |
| 61 | Supplying and fixing copper strip bus-bars suitable for following size & cross sectional area 415 volts capacity 4 No. each in the existing enclosure with all accessories including connections etc. as required. |
| 62 | Copper Bus Bar 100 Amp (25.4x3.17mm) |
| 63 | Supplying and fixing 4 pole MCCB 63 Amp Ics = 100% icu, 18KA & @ 415 volts, 50 Hz with thermal magnet in release and terminal spreaders in existing cubical panel complete with connection ,testing and commissioning etc as required. Make:- L&T/ Legrand/ Hager/ ABB as approved by Engineer-in -charge. |
| 64 | Supplying and fixing 4 pole MCCB 100 Amp Ics = 100% icu, 25KA & @ 415 volts, 50 Hz with thermal magnet in release complete with connection, testing and commissioning etc as required. Make:- L&T/ Legrand/ Hager/ ABB as approved by Engineer-in -charge. |
| 65 | Providing and fixing 100 AMP , four pole, 415 volts, On-Load change over switch in cubical panel front handle operation, including drilling holes in the cubical, making connections, etc. as required. Make:- L&T/ Legrand/ Hager/ABB as approved by Engineer-in -charge. |
| 66 | Supplying and fixing of voltmeter flush mounting 96x96 mm inbuilt selector switch CT/PT site programmabe accuracy class ;0.5 complete with connection ;testing and commissioning etc as required.make as per L&T (cat no WL132020OOOO)Siemens/ ABB as approved by Engineer-in -charge. |
| 67 | Supplying and fixing of ammeter flush mounting 96x96 mm inbuilt selector switch CT/PT site programmabe accuracy class;0.5 complete with connection ;testing and commissioning etc as required.make as per L&T (cat no WL131020OOOO)Siemens/ ABB as approved by Engineer-in -charge. |
| 68 | Supplying and fixing CT coil 200/5 amp with burden of VA 15 accuracy class -1 Make:- Automatic Electric Ltd/ L&T/ Legrand/ABB as approved by Engineer-in -charge. |
| 69 | S/F indicator set R,Y & B with 3 Nos Kit kat (LED type) to shown the three indicating in the existing pannel complete etc as required. |
| 70 | S/F Rubber mat 1x2 meter long 12mm thick infront of main panel as required including carriage of material with in all leads and lift. |
| 71 | S/F Shock treatment chart on the existing wall etc as required including carriage of material within all leads and lift. |
| 72 | Supply and fixing of exhaust fan louver shutter for 300/380mm exhaust fan on the existing wall 12 mm thick ply board,painting for suitable size of exhaust fan hole complete in all respect as required. |
| 73 | Supplying and fixing of DLP 105x50 mmPVC adaptable trunking on the exiting wall at required height from lower level for power connection, light connection and net working connection including partition chip flexible cover end cap. Make:- Legrand /MK/Schneider as approved by Engineer-in -charge. |
| 74 | Providing, laying and fixing of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade on surface etc. of the required size. Make:- Plaza/ Popycab/ Finolex/ Havell's as approved by Engineer-in-charge. |
| 75 | Armoured cable 35 sq. mm (3.5 core) |
| 76 | Providing and laying of one number additional PVC insulated and PVC sheathed armoured / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. Make:- Plaza/ Popycab/ Finolex/ Havell's or its equivalent as approved by Engineer-in-charge. |
| 77 | Armoured cable 35 sq. mm (3.5 core) |
| 78 | Supplying and fixing true power make advanced earthing system having copper pipe 3 meter long 50 mm dia with terminal size 50x6 mm ,internal strip size 25x3 with 50 Kg compound including exvation of pit and refiling the same and making earthing pit cover 12 inch dia as required complete in all respect. make :- True power /Earth Plus/Ashloka as per best satisfaction of Engineer-in -charge. |
| 79 | Providing and fixing 4 mm dia. copper wire on surface or in recess for loop earthing as required. |
| 80 | Supplying and installing following size of perforated hot dipped G.I cable trays (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sectons joined with connectors, suspended from the ceiling with G.I. suspenders including G.I bolts & nuts,etc as required. |
| 81 | 225 mm width X 50 mm depth X 1.6 mm thickness Please Enable Macros to View BoQ information |