| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / heavy class PVC conduit having wall thickness minimum 2 mm, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Make:-ANCHOR/ FINOLEX/PLAZA |
| 2 | Group C |
| 3 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.Make:-ANCHOR ROMA CLASSIC,/ANCHOR BY PANASONIC/(L&T ENTICE/ LEGRAND (MYRIUS) |
| 4 | Supplying and fixing suitable size GI box with modular plate and cover in FRLS on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.Make:-ANCHOR ROMA CLASSIC,/ANCHOR BY PANASONIC/(L&T ENTICE/ LEGRAND (MYRIUS) |
| 5 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed heavy class PVC conduit having wall thickness 2.0mm as required . Make:- ANCHOR/FINOLEX/PLAZA |
| 6 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 7 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 8 | 4 X 4 sq. mm + 2 X 4 sq. mm earth wire |
| 9 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 10 | 4 X 16 sq. mm + 1 X 6 sq. mm earth wire |
| 11 | Supplying and fixing Computer board comprising 3 nos 5 amp modular switches & Sockets , G.I box 2 module for jack box and G.I Box 12 module for 5 amp switchs and 5 amp sockets comprising frame and cover plate for each 2 module metal box and 12 module metal box , one no computer jack (RJ-45) with shutter including connections etc as required.Make:-ANCHOR ROMA CLASSIC/ ANCHOR BY PANASONIC/(L&T ENTICE/ LEGRAND (MYRIUS) |
| 12 | Providing, Installation, testing and commissioning of BLDC ceiling fan (5 star rating), including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mm twin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required: Make:-USHA/ORIENT/ CROMPTON as approved by Engineer-in -charge. |
| 13 | Ceiling Fan 1400 mm sweep |
| 14 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.Make :-Anchor (Roma classic ) /L&T (Entice) /Legrand(Myrius) as approved by Engineer-in -charge. |
| 15 | Providing and installation exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required: Make:-USHA/ORIENT/CROMPTON as approved by Engineer-in -charge. |
| 16 | Exhaust Fan, Light duty, (Domestic)300mm sweep |
| 17 | Providing and fixing LED Batten Light of IP40 Led fixture 40 W+/- 1W with Surface Mounted 4 Feet with Polycarbonate diffuser with Extruded aluminium housing having minimum system lumen output 1000 lumens and system lumen efficacy of 100 lm/W with P.F.>0.95 with THD<20% ,CRI 80 .The LED with Useful life of 50000 Hrs at L70 . The LEDs used in the luminaire shall have CCT of ANSI Bin 5700 K with CRI of minimum 80.The Input voltage range shall be 150V to 270V, 50/60 HZ complete with all accessories, including connections, testing and commissioning etc.as required complete in all respects. Make: Jaquar /Philips Wipro Cat. No. LL24-541-XXX-57-CD. |
| 18 | Providing, Installation, testing and commissioning of Glazed LED 10 Watt Batten 600mm long( Mirror Light) High quality design aluminum extruded decorative end caps as per best satisfaction of Engineer-in-Charge. Make: , Wipro Cat No L20-111-XXX-65NE3), Jaquar /Philips with five year warranty as approved by Engineer-in- charge. |
| 19 | Supplying and fixing batten/ angle holder including connection etc. as required. Make:-Anchor as approved by Engineer-in -charge. |
| 20 | Providing and installation of stationary storage type Electric water heater (Geyser) of various sizes by means of expansion-bolts with nuts and washers, including embedding of expansion-bolts in the wall, making good the damages, electrical connections, testing etc. complete as required:- Make USHA/RECOLD/JAQUAR as approved by Engineer-in -charge. |
| 21 | 25 Liter capacity water heater (Cat-A) |
| 22 | Supplying and fixing 32 amps, 240 volts, TPN industrial type, socket outlet, with 3 pole and earth, metal enclosed plug top alongwith 32 amps “C” curve, TP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.Make:-HAGER/L&T/ LEGRAND as approved by Engineer-in -charge. |
| 23 | 30 A TPN, industrial type socket |
| 24 | Providing and fixing following rating and breaking capacity Type FN S-D-F Suitable for DIN fuse -link (TPN) in open execution with Terminal Shouds on both side and Phase Barriers included and Telescopic Shaft for depth adjustment door interlock & padlock facility including drilling holes in Enclosuer panel, making connections, etc. as required.Make:-HAGER/L&T/ LEGRAND as approved by Engineer-in -charge. |
| 25 | FN TPN 63 Amp |
| 26 | Providing and Fixing of IP20 LED fixture of 18 watt +/- 1 W LED Surface Mounted Downlighter Round Shape with minimum system lumen efficacy of 100 lm/W with Polycarbonate housing,pressure die cast heat sink and P.F.>0.95 with THD<10% ,CRI 80.The LED shall be tested with LM80-08 standard with Useful life of 50000 Hrs at L70 . The LEDs used in the luminaire shall have CCT of ANSI Bin 5700 K with CRI of minimum 80.The Input voltage range shall be 150V to 270V, 50/60 HZ complete with all accessories, including connections , testing and commissioning etc.as required complete in all respects.Make Wipro/Panasonic/Jaquar Cat. No. PDLM 36188 . |
| 27 | Supplying and fixing 6 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Make:-ANCHOR/L&T/ LEGRAND as approved by Engineer-in -charge. |
| 28 | Providing and fixing following rating and breaking capacity 4 pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.Make:-ANCHOR/L&T/ LEGRAND as approved by Engineer-in -charge. |
| 29 | 32 to 100Amp 18KA |
| 30 | Supplying and fixing of Segregated tripple pole and neutral 12 ways surface/ recess mounting, 7 Segment 415volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, with provision to mount MCCB incomer , DP MCB/RCCB sub-incomer in each phase and SP MCBs as outgoing (but without MCB ’s and incomer)complete with tinned copper din-bar, wire-set, neutral link, earth bar, detachable gland plate, cable interconnections, including earthing etc. as required:-Make:-ANCHOR/L&T/ LEGRAND as approved by Engineer-in -charge. |
| 31 | TPN Phase Segregated DB 12 way, |
| 32 | Supplying and fixing 1.5 ton invertor split type air conditioner Hot and Cold with five year warranty ,including advanced filter ,E saver mode , quit mode, dual display ,auto clean ,anti bacteria filter jet Cool on/off timer sleep mode compressor cord less remote complete in all respect as per comprising to ISI with latest amendment suitable to operate on 230 volt /240 volt +_ 10 % AC supply capable to perform the function of cooling dehumidification air circulation ventilation and fitting in size of nominal cooling capacity and drain pipe 20 mm dia approximately 3mrs long 2 nos copper pipe with insulator for inlet and outlet approximatey 3 mtrs long and out door unit of split type A.,C including carrigae of material with in all leads and lift. Make -Daikin (model:FTHT50)/ O General/Mitsubishi as approved by the Engineer Charge. |
| 33 | Installation Chargeges |
| 34 | Supplying and fixing of voltage stabilizer upto 1.5 ton ac having specification Input voltage range 170-270v ,Digital display,Under voltadge Protection,Over voltage protection including connections, testing and commissioning as required: Make:- Microtek /V Gaurd /Godrej as approved by Engineer-in-charge(Three year warranty) Model Pearl MCU 4170+ |
| 35 | Supplying and erection of following depth sheet metal cubical pedestal of suitable dimensions with plus-minus 5 cm variation made from (50 mm x 50 mm x 6 mm thick) M.S. angle iron frame, covered with 1.6 mm thick M.S. sheet duly welded on five sides & front side hinged, complete with locking arrangement with sufficient No. vertical and horizontal intermediate switchgear supporting members each of M.S. flat 50mmx6mm thick of suitable length duly welded. The cubical pedestal shall have cable entry box at one or two sides and 4 No. legs of 50mmx50mmx6mm thick M.S. angle iron each 60 cm long including, powder coated painting and bonding to the existing earth etc., the same shall be erected in the 1:2:4 cement concrete plat-form of suitable dimensions 15 cm high from ground level and 45 cm thick. The cubical pedestal shall be 15 cm from the top of cement concrete plat-form:-The panel should be approved /Tested from the CPRI lab.& should confirmed to ISI: 64139 I) i) 300 mm Deep |
| 36 | Supplying and fixing copper strip bus-bars suitable for 200 Amp. 415 volts capacity 4 No. each of cross-sectional area (16mmx3.17mm), in the existing enclosure with all accessories including connections etc. as required:-: |
| 37 | S/F indicator set RYB with 3 Nos Kit kat (LED type) to shown the three indicating in the existing pannel complete etc Make L&T/ Legrand/ Hager,as required. |
| 38 | Supplying and fixing of voltmeter inbuilt selector switch CT/PT site programmabe accuracy class 0.5 complete with connection ;testing and commissioning etc as required. Make L&T/ Legrand/ Hager/ ABB as per best satisfaction of Engineer-in -charge. |
| 39 | Supplying and fixing of ammeter inbuilt selector switch CT/PT site programmabe accuracy class 0.5 complete with connection ;testing and commissioning etc Make L&T/ Legrand/Hager/ ABB as per best satisfaction of Engineer-in-charge. |
| 40 | Providing and fixing following rating and breaking capacity 4 pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.Make:-ANCHOR/L&T/LEGRAND |
| 41 | 200-250 A 36 KA |
| 42 | Earthing with G.I. earth plate 600x600x6mm thick including accessories providing masonary enclosure wih cover plate having locking arrangement and watering pipe of 2.7 mtr. Long with with charcoal /coke and salt etc. as required complete in all respect. |
| 43 | Providing & fixing 6 SWG G.I wire on surface or in recess for loop earthing as required. Please Enable Macros to View BoQ information |