| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed heavy class PVC conduit having wall thickness minimum 2 mm with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required Make :Plaza/Anchor/Finolex/L&T. |
| 2 | GroupC |
| 3 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed heavy class PVC conduit having wall thickness 2.0mm as required .Make:-Plaza/ Anchor/ Finolex/L&T . |
| 4 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 5 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 6 | 4 X 4 sq. mm + 2 X 4 sq. mm earth wire |
| 7 | 2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 8 | 2X 4 sq. mm + 2 X 4 sq. mm earth wire |
| 9 | 2X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 10 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.Make:-Anchor/SSK/Legrand. |
| 11 | 5/6 amps switch |
| 12 | 3pin 5/6 amps socketoutlet |
| 13 | Supplying and fixing two rotary stepped type electronic fan regulator on the existing switch box including connections etc. as required.Make:-Anchor/SSK/Legrand. |
| 14 | Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in FRLS on including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings) Make :- Make:-Anchor/SSK/Legrand AS approved by Engineer-in -charge |
| 15 | Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in FRLS on including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required.Make :- Make:-Anchor/SSK/Legrand as approved by Engineer-in -charge |
| 16 | Supplying and fixing PVC batten/ angle holder including connections etc. as required.Make:-Anchor/SSK/Legrand |
| 17 | Supplying and fixing LED. Lamp 9 watts E-27 base in the existing batten holder/pendent holder . Make:- Wipro /Havells/Jaquar |
| 18 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Make L&T/ABB/Hager/Anchor as approved by Engineer-in -charge |
| 19 | Single pole.6 Amp Cat-A. |
| 20 | Single pole.16 Amp Cat-A. |
| 21 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as requiredMake L&T/ABB/Hager/Anchor as approved by Engineer-in -charge.Make L&T/ABB/Hager/Anchor as approved by Engineer-in -charge |
| 22 | 63 Amps. Cat-A. |
| 23 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.)Make L&T/ABB/Hager/Anchor as approved by Engineer-in -charge |
| 24 | 63 Amps. Cat-A. |
| 25 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator) Make L&T/ABB/Hager/Anchor as approved by Engineer-in -charge |
| 26 | MCBDB 12 WAY D/Door |
| 27 | Providing, Installation, testing and commissioning of BLDC ceiling fan (5 star rating), including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mm twin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required:Make:- Usha/Orient/Crompton as approved by Engineer-in-charge(Five year warranty) |
| 28 | Ceiling Fan 1200 mm sweep |
| 29 | Supplying and fixing Aluminium batten LED 22 watt, 6000k, (Five YEAR WARRANTY ) and it should be compatible with specification i.e. Power Factor > .9, Harmonic Distortion<10% and efficacy >100 Lumens per watt, suitable for input voltage: AC 220-240 V, 50/60Hz, complete with all accessories, connections, testing and commissioning etc. Make:- jaquar/Philips/Panasonnic/wipro or as approved by Engineer-in-Charge |
| 30 | Supplying and fixing street light LED 45 watt with G.I bracket die cast Aluminium housing with frame and toughened glass, pipe mounting 5700k, (Five YEAR WARRANTY ) and it should be compatible with specification e.i. Power Factor > .9, Harmonic Distortion<10% and efficacy >100 Lumens per watt, suitable for input voltage: AC 220-240 V, 50/60Hz, complete with all accessories, connections, testing and commissioning etc. Make - Jaquar/Panasonic /Philips/wipro or as approved by Engineer-in-Charge |
| 31 | Providing and installation exhaust fan of following sizes in the existing opening,including making the hole to suit the size of the above fan, making good thedamages, connections, testing and commissioning etc. as required: Make:- Usha/Orient/Crompton as approved by Engineer-in-charge(Five year warranty) |
| 32 | Exhaust Fan, Light duty, (Domestic) 300 mm sweep |
| 33 | Supply and fixing exhaust fan louver shutter for 300/380mm exhaust fan on the existing wall painting including 12 mm thick wooden ply board for suitable size of exhaust fan hole. |
| 34 | Supply,Erection,Installation and commissioning of Uniearth maintenance free chemical earthing system consisting of environment friendly ground enhancing compound 'G.E.C' 50kg or as required at site having anticorrosive and hygroscopic properties to replace excavated soil. It should consist of Uniearth copper bonded electrodes, as per site conditions and soil resistivity at various depth levels and different terrains. The electrodes should have coating of 250 microns of molecularly bonded pure electrolytic copper(99.9%) in 2 meter length,17.2 mm diameter,terminal joint 200X25X6mm GI Strip with exothermic welds. The electrode should be duly tested and certified by CPRI for 30kA short time current test for 1 sec rms. Make : True Power/Earth Plus/Ashloka as approved by Engineer-in-Charge |
| 35 | Providing and fixing (4 mm dia.) copper wire on surface or in recess for loop earthing as required. |
| 36 | Supplying and fixing Aluminium batten LED 10 watt, 6500k, and it should be compatible with specification i.e. Power Factor > .9, Harmonic Distortion<10% and efficacy >100 Lumens per watt, suitable for input voltage: AC 220-240 V, 50/60Hz, complete with all accessories, connections, testing and commissioning etc. Make:- JAQUAR/ Philips/ Panasonnic/Wipro, as approved by Engineer-in-Charge (FIVE YEAR WARRANTY ) |
| 37 | Supplying and fixing Ding Dong bell suitable for single phase, 230 volts, complete as required.Anchor/SSK/Legrand Please Enable Macros to View BoQ information |