| 1 | Wiring for light point / ceiling fan point /wall fan point including 6 amp 3 pin socket/call bell point / exhaust fan point with 1.5 sq mm FRLS /HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable size GI box and earthing the point with 1.5 sq mm,1.1 kV, FRLS/HFFR PVC insulated copper conductor single core cable etc as required. |
| 2 | Upto 6 metres ( Group A ) |
| 3 | Above 6 metres ( Group B ) |
| 4 | Above 9 metres ( Group C ) |
| 5 | Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor , single core cable in surface / recessed medium class PVC conduit as required . |
| 6 | 2 X 1.5 sq mm + 1 X 1.5 sq mm for earth wire |
| 7 | 2 X 2.5 sq mm + 1 X 2.5 sq mm for earth wire |
| 8 | 2 X 4 sq mm + 1 X 4 sq mm for earth wire |
| 9 | 2 X 6 sq mm + 1 X 6 sq mm for earth wire |
| 10 | 2 X 16 sq mm + 1 X 6 sq mm for earth wire |
| 11 | 4 X 6 sq mm + 2 X 6 sq mm for earth wire |
| 12 | 4 X 16 sq mm + 2 X 6 sq mm for earth wire |
| 13 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 14 | 20 mm |
| 15 | 25 mm |
| 16 | 32 mm |
| 17 | Supplying and fixing metal box/ Junction box of following sizes on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as require(ISI Approved). |
| 18 | 75 mm X 75 mm X 60 mm deep |
| 19 | 100 mm X 100 mm X 60 mm deep |
| 20 | 150 mm X 150 mm X 60 mm deep |
| 21 | Supplying and fixing following sizes/modules, GI / PVC box along with modular base & cover plate for modular switches in recess etc as required. |
| 22 | 1 or 2 Module (75 mm X 75 mm ) |
| 23 | 3 Module (100 mm X 75 mm ) |
| 24 | 6 Module (200 mm X 77 mm ) |
| 25 | 12 Module (200 mm X 150 mm ) |
| 26 | Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. |
| 27 | 5 /6 Amps Switch |
| 28 | 15 /16 Amps Switch |
| 29 | 3 pin 5 /6 Amps Socket Outlet |
| 30 | 6 pin 15 / 16 Amps Socket Outlet |
| 31 | Blanking Plate :- |
| 32 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 33 | Supplying and fixing single Pole blanking plate in the existing MCB DB complete etc. as required. |
| 34 | Supplying & fixing suitable size GI box/ PVC box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required with earthing attachment (Complete unit) for Split/Window Airconditioner. |
| 35 | Installation, Testing, Commissioning of wall bracket/ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. including 3 X1.5 sq mm FRLS/ HFFR PVC insulated copper conductor single core cable and earthing etc as required. |
| 36 | Supplying and fixing of extra conduit down rod of 20 cm Length (heavy gauge) GI pipe 15 mm dia wiring with 3 X 1.5 sq mm single core FRLS/ HFFR PVC cu cable including cutting, threading and painting etc as required.(Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored.) |
| 37 | Hot Dipped Galvanized Iron Cable Tray :- Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers GI Suspenders/ fixing on wall with suitable G.I. angle i/c base of suitable size GI angle, GI bolts & nuts, fastner etc as required. |
| 38 | 100 mm width X 50 mm depth X 1.6 mm thickness |
| 39 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 40 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"bends\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers GI Suspenders/ fixing on wall with suitable G.I. angle i/c base of suitable size GI angle, GI bolts & nuts, fastner etc as required. |
| 41 | 100 mm width X 50 mm depth X 1.6 mm thickness |
| 42 | 101 mm width X 50 mm depth X 1.6 mm thickness |
| 43 | Supplying and installing following size of Perforated Hot Dipped Galvanised Iron cable tray \\"Tee\\" (Galvanisation thichness not less than 50 microns) perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers G.I. suspenders/ fixing on wall with suitable G.I. angle i/c base of suitable size GI angle, GI bolts & nuts, fastner etc as required. |
| 44 | 100 mm width X 50 mm depth X 1.6 mm thickness |
| 45 | 101 mm width X 50 mm depth X 1.6 mm thickness |
| 46 | Supplying and fixing double door 12 Way Vertical TPN MCB Distribution board for MCCB incomer upto 250 A with IP-42/43 protection, concealed /surface in wall after cutting the wall/on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. |
| 47 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc. as required. |
| 48 | Providing and fixing following rating and breaking capacity and pole MCCB with adjustable thermal and fixed magnetic setting and terminal spreaders link in existing PCC Panel /MCCB DB/MCCB SS Enclosure including drilling holes in cubicle panel, making connections, etc. as required. |
| 49 | 250 A,36 KA, FP MCCB |
| 50 | Supply of one number Alminium conductor PVC insulated and PVC sheathed / XLPE, Armoured Power Cable A2XFY of 1.1 kV grade,, Confirming to IS: 1554/7098 (Part -1) 1988 with latest amendments. |
| 51 | 2X 10 sq mm |
| 52 | 3.5X 25 sq mm |
| 53 | 3.5X150 sq mm |
| 54 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on Wall Surface as required incl. S+F of 1 X 10 SWG rust free GI wire for E.C.C making holes and manding good the damages to original finish incl painting.( Cable Dept supply) |
| 55 | Upto 35 sq mm ( clamped with 1 mm thick rust free saddle) |
| 56 | Above 35 sq mm and upto 95 sq mm (clamped with 25 X 3 mm rust free MS flat clamp) |
| 57 | Above 95 sq mm and upto 185 sq mm (clamped with 25/40 X 3 mm rust free MS flat clamp) |
| 58 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on Cable Tray along with S+F of 10 SWG GI wire as earth wire as required. |
| 59 | Upto 35 sq. mm (clamped with 1mm thick rust free saddle @ 3 sets per metre.) |
| 60 | Above 35 sq. mm and upto 95 sq. mm (clamped with 25 X 3mm rust free MS flat clamp @ 3 sets per metre.) |
| 61 | Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40 X 3mm rust free MS flat clamp @ 3 sets per metre.) |
| 62 | Laying of cable as below after Cutting Floor/Pavement/Wall and making holes incl embedding the cable at an average depth as below and mending good the damages to original finish incl S+F of 1 X 10 SWG wire for ECC (Cable Dept Supply) |
| 63 | From 2.5 sq mm to 35 sq mm at an average depth of 75 mm in floor/ pavement/wall etc. |
| 64 | Above 35 sq mm to 95 sq mm at an average depth of 100 mm in floor/ pavement/wall etc. |
| 65 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size Direct in Ground including excavation, sand cushioning, protective covering @ 8 bricks per metre on each cable and refilling the trench etc. as required. |
| 66 | Upto 35 sq. mm |
| 67 | Above 35 sq. mm and upto 95 sq. mm |
| 68 | Above 95 sq. mm and upto 185 sq. mm |
| 69 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing Masonary Open Duct incl mending good the damages to original finish. (Cable Dept Supply). This includes S+F 10 SWG GI earth wire for cables. |
| 70 | Upto 35 sq mm . |
| 71 | Above 35 sq. mm and upto 95 sq. mm |
| 72 | Above 95 sq. mm and upto 185 sq. mm |
| 73 | Supplying and making End Termination with brass compression gland and lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 kV grade as required. |
| 74 | 2 X 10 sq mm (19 mm ) |
| 75 | 2 X 16 sq mm ( 22 mm ) |
| 76 | 4 X 16 sq mm (28 mm ) |
| 77 | 3.5 X 25 sq mm (28 mm ) |
| 78 | 3.5 X 35 sq mm (32 mm ) |
| 79 | 3.5 X 95 sq mm (45 mm ) |
| 80 | 3.5 X 150 sq mm (50 mm ) |
| 81 | Supply and Fixing medium gauge Gi pipe (ISI-Medium) protection for cable entry including bending the pipe to the required shape complete as required with laying of wire/cable through pipe. |
| 82 | 25 mm |
| 83 | 40 mm |
| 84 | Supplying and Fixing DP/ FP Sheet Steel Enclosure on surface/recess complete with connection,testing and commissioning etc.as required without MCB/MCCB. |
| 85 | Two Pole Enclosure for MCB |
| 86 | Four Pole Enclosure for MCB |
| 87 | Four Pole Enclosure for MCCB |
| 88 | Supplying and fixing 32 Amps,415 Volt TPN Industrial type socket outlet,with 4 pole and earth (3P+N+E),metal enclosed plug top alongwith 32 Amps,\\"C\\" curve, TPN, MCB, in sheet steel enclosure,on surface or in recess with chained metal cover for the socket out let and complete with connections,testing and commissioning etc,as required. |
| 89 | Supplying and fixing 63 Amps,415 Volt TPN Industrial type socket outlet,with 4 pole and earth (3P+N+E),metal enclosed plug top alongwith 63 Amps,\\"C\\" curve, TPN,MCB, in sheet steel enclosure,on surface or in recess with chained metal cover for the socket out let and complete with connections,testing and commissioning etc,as required. |
| 90 | Supplying and fixing following way, Single Pole and Neutral, IP- 43, sheet steel, MCB distribution board, 240 V /415 V on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). |
| 91 | 6 Way , Double door |
| 92 | 12 Way Double door |
| 93 | Supplying and fixing of following ways surface/ recess mounting, Horizontal type, IP-43,415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 Amps, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. |
| 94 | 6 Way (4 + 18), Double door |
| 95 | Supplying and fixing of following ways surface/ recess mounting, Vertical Type,IP-43, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 Amps, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TP DB is normally used where 3 phase outlets are required.) |
| 96 | 8 Way (4 + 24), Double door |
| 97 | Supplying and fixing double door 12 Way Vertical TPN MCB Distribution board for MCCB incomer upto 250 A with IP-42/43 protection, concealed /surface in wall after cutting the wall/on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. |
| 98 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc. as required. |
| 99 | Providing and fixing following rating and breaking capacity and pole MCCB with adjustable thermal and fixed magnetic setting, Ics = 100% Icu and Operational Voltage 690 V and 02 sets of terminal spreaders link in existing PCC Panel /MCCB DB/MCCB SS Enclosure including drilling holes in cubicle panel, making connections, etc. as required. |
| 100 | 250 Amps,36KA Four Pole |
| 101 | Supplying and fixing 5 Amps to 32 Amps rating, 240/415 V,10 kA,“C” curve, Miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 102 | Single Pole |
| 103 | Double Pole |
| 104 | Triple Pole |
| 105 | Triple Pole and Neutral |
| 106 | Supplying and fixing 40 Amps to 63Amps rating, 240/415 V,10 kA,“C”curve, Miniature Circuit breaker suitable for inductive load of following poles in the existing MCB DB or in enclosure complete with connections, testing and commissioning etc. as required. |
| 107 | Single Pole |
| 108 | Double Pole |
| 109 | Triple Pole |
| 110 | Four Pole |
| 111 | Lightning Conductor :- |
| 112 | Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, GI tube, having single prong at top, with 85 mm dia 6 mm thick GI base plate including holes etc, complete as required |
| 113 | Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. (Jointing shall be done by Welding with 4 inch. overlapping over the tape and anti corrosive paint on the joint / by Overlaping and with 02 sets of G.I. nut, bolt & spring washer spaced at 50 mm). |
| 114 | Providing and fixing GI tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For horizontal run).(Jointing shall be done by Welding with 4 inch. overlapping over the tape and anti corrosive paint on the joint / by Overlaping and with 02 sets of G.I. nut, bolt & spring washer spaced at 50 mm). |
| 115 | Providing and fixing GI tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.( For Vertical run).(Jointing shall be done by Welding with 4 inch. overlapping over the tape and anti corrosive paint on the joint / by Overlaping and with 02 sets of G.I. nut, bolt & spring washer spaced at 50 mm). |
| 116 | Providing and fixing testing joint, made of 20 mm X 3 mm thick GI strip,125 mm long, with 4 nos rust free GI bolts, nuts,check nuts and spring washers etc,complete as required . |
| 117 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure of size not less than 30 cmX 30 cmX 30 cm with cast iron /MS frame with MS cover plate, 6 mm thick having locking arrangements shall be suitably embedded in the masonry enclosure and 20 mm dia Medium class GI watering pipe of 2.7 meter long etc. attached to the electrodes and a funnel with mesh on the top of this pipe for watering the earth shall be provided with charcoal/coke and salt etc. as required. |
| 118 | Supplying and fixing 25X5 mm G.I strip in 40 mm dia G.I. pipe from earth electrode, including connection/terminating with G.I. nut, bolt,spring,washer and excavation with re-filling etc as required (Jointing shall be done by Welding with 4 inch. Overlapping over the tape and anti corrosive paint on the joint / by Overlaping and with 02 sets of G.I. nut, bolt & spring washer spaced at 50 mm) |
| 119 | Supplying and laying 25X5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with nut, bolt,spring,washer etc as required.(Jointing shall be done by Welding with 4 inch. overlapping over the tape and anti corrosive paint on the joint / by Overlaping and with 02 sets of G.I. nut, bolt & spring washer spaced at 50 mm). |
| 120 | Supplying and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 121 | Providing and fixing 25X5 mm G.I strip on Surface or in recess with fixing clamp for connections etc. as required.(Jointing shall be done by Welding with 4 inch. Overlapping over the Strip and anti corrosive paint on the joint / by Overlaping and with 02 sets of G.I. nut, bolt & spring washer spaced at 50 mm) |
| 122 | Supplying & fixing earth bus of 50 mm x 5 mm copper strip on surface of wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with brass bolts, nuts, washers, spacing insulators etc. as required. |
| 123 | Filling available excavated earth (excluding rock) in trenches, sides for earthing/ foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, within lead up to 50 metres including the cost of carried earth. |
| 124 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 125 | 2 X 16 sq. mm |
| 126 | 3½ X 25 sq. mm / 3½ X 35 sq. mm / 3½ X 50 sq. mm |
| 127 | 3½ X 70 sq. mm |
| 128 | 3½ X 95 sq. mm |
| 129 | Supply, Installation, Testing and Commissioning of Ceiling fan with Brush Less Direct Current (BLDC) Motor with copper winding, Class of insulation: B, 3 nos. metal (Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, Steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374 -2019), THD (Total Harmonic Distortion) less than 10%, Suitable for operation with electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, Ceiling Fan Complaint to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. |
| 130 | 1200 mm sweep, Service Value (CM/Min/Watt ) minimum 6.00, Air delivery 210 CM/Min(Minimum). |
| 131 | Providing and fixing M.S. fan clamp/ Highbay Light fixing clamp of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs during laying or Existing Beams of angle iron Structure, including painting the exposed portion of loop, all as per standard design complete. |
| 132 | LED Highbay/Mediumbay light (System lumen efficacy ≥150 to <160 lm/Watt) :- Supplying, Installation, Testing & Commissioning ofof Ceiling (Surface/Suspended) mounted Vertical Round type Highbay/ Mediumbay Industrial PDC housing Body LED luminaire with Polycarbonate Cover including electronic driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140 - 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection & all accessories of the following Specification :- CCT >/= 5700K, Lumen >/= 10000, CRI >/= 70, P.f >/= 0.95, Efficacy(Lumen/watt) >/=150, THD < 10 %, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥150 <160 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be mitted. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Equivalent to Philips Item Model - BY515P LED100S 5700 WB PSU GR. |
| 133 | LED Batten light (System lumen efficacy ≥105 to <120 lm/Watt) :- Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of Powder Coated CRCA Sheet Body (Thickness>=0.50 mm) material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140 - 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P.F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be mitted. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > = 1.20 mm) |
| 134 | 18 - 22 watt |
| 135 | 24 - 26 watt |
| 136 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥120 <135 lm/Watt) :- Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-6,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 137 | 36 watt |
| 138 | Heavy duty Industrial applications Exhaust Fan :- Supply, Installation, Testing and Commissioning of Industrial applications 450 mm Sweep, 220 - 240 volt, a.c., 50 HZ, Single phase, metal blades with double ball bearing, powerful capacitor type durable motor, rubber mountings with metal rigid frame Heavy duty Exhaust Fan complete with all accessories of the following specification:- Power Input =/ < 350 Watts, Speed = /< 1500 RPM, Air Delivery = /> 6000 CMH, Noise label =/ < 70 db and mounting with grouted frame/clamp arrangements with necessary accessories including Supply & fixing of metal louver of suitable size. |
| 139 | Making Exhaust Fan hole in wall and making good the damages and smooth cement finish etc. as practicable as possible and providing necessary length of PVC insulated wire and making connection for exhaust fan of following diameter |
| 140 | Upto 60 Cm (24\\") |
| 141 | Supply, Installation, Testing and Commissioning of 220 - 240 volt a.c., 50 HZ, single phase Input Voltage, 400 mm Sweep Wall Mounted Fan complete with Pull-Cord mechanism for speed control & oscillation including all accessories of the following Specification :- White in colour, Power consumption = 60 Watt, Speed =1350 RPM, Air delivery >/= 80 CMM and connection with 3X1.5 sq mm FRLS PVC insulated copper conductor single core cable and earthing etc as required. |
| 142 | Supply, Installation, Testing and Commissioning of 250 mm Sweep, 220 - 240 volt, a.c., 50 HZ, Single phase, Plastic Ventilating Fan complete with dust protection shutter & all accessories of the following specification :- Power Input =/ < 40 Watts, Speed = /< 1300 RPM, Air Delivery = /> 750 CMH and mounting with grouted frame/ clamp arrangements with necessary accessories & Connection with mending good to the damages. |
| 143 | Dismantling of following items with good condition and shifting to site store etc. including mending good the damages to original finish etc. as required as per instructions by the EIC. |
| 144 | Light Fittings/ Ceiling Fan/ Wall Fan/ Exhaust Fan/ Modular Power Board with switch & socket etc. including accessories, old wiring & cable. |
| 145 | SPN DB/ Main switch/ Industrial plug & socket DB/ Metal Enclosure etc. including accessories, old cable & wiring. |
| 146 | VTPN MCCB DB/ TPN MCB DB/ Small Size Power Supply Panel etc. including accessories, old cable & wiring. |
| 147 | Medium Size Power Supply Panel etc. including accessories, old cable & wiring. |
| 148 | Portable Fire Extinguishers :- |
| 149 | Supplying, installation, testing & commissioning ISI marked ABC Powder Stored pressure type fire extinguisher containing MAP - 50% Dry powder with 4A:144B Fire Rating conforming to IS 15683:2018, Capacity : 6 KG etc. complete as required including necessary Test Certificate & Warranty Certificate. |
| 150 | Supplying, installation, testing & commissioning ISI marked Carbon Dioxide(CO2) Portable type fire extinguisher with 55B Fire Rating conforming to IS : 15683:2018 , Capacity : 4.5 Kg etc. complete as required including necessary Test Certificate & Warranty Certificate. Please Enable Macros to View BoQ information |