| 1 | Removal of plants/ ficus growth by pulling out root system embedded in masnory, cutting stem and application of hing/gur/lime formulation as specified by the Architect or other patented chemical biocide treatment such as biocide 'Glycel' (isoproplamine salt of glyphosate) or other chemical as specified by the Engineer in charge etc. complete. |
| 2 | Clearing grass and removal of rubbish upto a distance of 50 metres outside the periphery of the area. |
| 3 | Cutting down trees including trunks and branches with girths above 30cm to 60cm and stacking the materials neatly with all lifts and lead of 1000 m as directed and earth filling in the depression / pit if any |
| 4 | Dismantling the existing light, fan, bell, clock, independent plug point, wiring including circuit mains of all types along with accessories etc. complete as per specification No: WG-DM/PW |
| 5 | Providing and fixing double scaffolding system (cup lock type) on the exterior side of building / structure, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40 mm dia M.S. tube, placed 1.5 metre centre to centre,horizontal & vertical tubes joint with cup & lock system with M.S.Tubes, M.S. tube challis, M.S.clamp sand staircase system in the scaffolding forworking platform etc.and maintaining it in a service able condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge. |
| 6 | Removing the existing cement plaster of any thickness without causing dust nuisance and stacking the debris upto a distance of 50metres or spreading in the compound and cleaning the site etc. complete |
| 7 | Removing G.I. or A.C. sheet roofing including purlins, principal rafters etc. including sorting service able and unserviceable materials, stacking the same as and where directed in the compound including scaffolding etc. complete. |
| 8 | Removing cement tiles or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all lead, lifts, etc.complete. |
| 9 | Removing doors and windows with frames and stacking the materials as directed with all leads, lifts etc. complete. |
| 10 | Dismantling the R.C.C. Work 1: 2: 4 and sorting out the materials such as steel etc. as directed and stacking them within the specified lead as directed etc. complete. |
| 11 | Dismantling brick masonary in lime or cement mortar and stacking the materials as directed with all lead, lifts, etc |
| 12 | Dismantling stone masonary in lime or cement mortar including stacking the materials as directed with all lead, lifts, etc.. |
| 13 | Raking out joints in lime or cement mortar and preparing the surface for re-pointing or replastering including disposal of rubbish to the dumping ground within 50 metres lead. |
| 14 | Removing purlins from roof including stacking as directed with all leads, lifts etc.complete |
| 15 | Removing rafters from roof including the material as directed with all leads, lifts etc.complete |
| 16 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary backfilling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means |
| 17 | Providing selected hard murum filling including laying in layers of 15 to 20cm with watering and compacting etc. complete. |
| 18 | Conveying the dismantled materials of stone masonry / debries /excavated material/soil murrum / rubbish material or vegetation / grass / shrubs etc. upto 5 km, away from the site and cleaning the site properly.(including conveying materials upto 50.00 m by head load) as directed by engineer in charge. |
| 19 | Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 cm to 20 cm thick including hand packing and compacting etc. complete. |
| 20 | Providing and laying cast in situ 1:2:4 Lime Concrete of trap/ granite/ quartzite/ gneiss metal for foundation and bedding as per detailed specifications and drawings or as directed including bailing out water,centring, formwork,laying/pumping,compacting, roughening them if special finish is to be provided, finishing if required with fine aggregate, preparing the lime mortar in lime miller and then mixing with coursed aggregate in drum mixer as per specifications including bailing out water,watering etc.complete. |
| 21 | Providing Un-coursed Rubble Masonry of trap stones in lime mortar 1:1½, in foundation and plinthas per amphitheatre / steps detailed specifications and drawings or as directed including the stones to be set in the work as received from the quarry, after merely knocking off weak corners and edges with the masons hammer, the stones shall be carefully laid so as to break joints, no joint shall exceed 12.5 mm. (½″) in thickness, every stone shall be set flush in mortar, the face stone shall be for greater size, and good beds, one through stone shall be inserted at least every 0.80 sq. mete (1 square yard), the joints shall be racked out carefully at least 25 mm. (1″) where pointing or plastering to be done, striking joints where no pointing or plastering is to be done, preparing the lime mortar in lime miller, bailing out water, watering and all exposed masonry work when handed over to be perfectly clean and free from all mortar stains etc. complete. |
| 22 | Providing and fixing Trap Stone Paving,Second Sort in lime mortar 1:1½, with size of stone [0.45 x 0.30 x 0.15 meter], as per detailed specifications and drawings or as directed including all stone slabs to of approved quality, hard, even, sound, durable and uniform thickness, the stones to be not finely chisel- dressed on the surface and the course to be of prescribed width, true for top 25 mm.(1″), the joints running true, the stones to be laid with joints not exceeding 8 mm. (5/16″) thick and to be evenly and firmly bedded flush in mortar on the concrete and no hollow left, side to be dressed true and as per shape at least half the depth from the face, preparing the lime mortar in lime miller, watering and all paving work when handed over to be perfectly clean and free from all mortar stains etc. complete. |
| 23 | Providing and fixing Stone Paving, Second Sort in lime mortar 1:1½, with size of stone 0.60 m x0.45 m x 0.30m, as per detailed specifications and drawings or as directed including all stone slabs to of approved quality, hard, even, sound, durable and uniform thickness, the stones to be not finely chisel-dressed on the surface and the course to be of prescribed width, true for top 25 mm. (1″), the joints running true, the stones to be laid with joints not exceeding 8 mm. (5/16″) thick and to be evenly and firmly bedded flush in mortar on the concrete and no hollow left, side to be dressed true and as per shape at least half the depth from the face, preparing the lime mortar in lime miller, watering and all paving work when handed over to be perfectly clean and free from all mortar stains etc. complete. |
| 24 | Providing Ashlar Rough-tooled Masonry of trap / granite stones in lime mortar 1:1½ with size of stone (0.45m.x 0.30 m.x0.20m.) in superstructure as per detailed specifications and drawings or as including the stones be of approved quality, colour, hard and free from defect of any kind, the faces exposed to view shall have fine dressed chisel draft, 25 mm. (1″) wide all around the edges and rough tooled between the drafts, and on all beds or joints, which shall not exceed 6 mm. (¼″), the stones shall be set in mortar, the stone shall be laid in regular course not less than 30 cm. (12″) in height averaging 4½ c. ft., the face stone shall be laid header and stretcher alternately, preparing the lime mortar in lime miller, scaffolding, watering and all masonry work when handed over to be perfectly clean and free from all mortar stains etc. complete. |
| 25 | Providing Ashlar Rough-tooled Stone Steps of trap / granite stones in lime mortar 1:1½ with size of stone 0.60 m. x 0.40 m. x 0.25 m. as per detailed specifications and drawings or as directed including the stones be of approved quality, colour, hard and free from defect of any kind, the stones shall be of exact size and shape, the shall be rough-tooled on exposed surface, holes for balusters should be cut in the steps before they are laid, each stone shall rest at least 3.8 cm. (1½″) on that below it, the beds or joints being in no case more than 3 mm. (⅛″), preparing the lime mortar in lime miller, watering and all steps work when handed over to be perfectly clean and free from all mortar stains etc. complete. |
| 26 | Providing Rectangular Coping Cut-stone First Sort, 20 cm. (8″) height and 60.00 cm. (2ꞌ00″) wide of trap / granite stones in lime mortar 1:1with size of stone 0.60m x 0.60m x 0.20m as per detailed specifications and drawings or as directed including the stones be of approved quality, colour, hard and free from defect of any kind, the stone shall be dressed full or to template, exposed face of the stones shall be fine chisel-dressed and all joints shall be in line and close and not more than 3 mm. (⅛″) thick, preparing the lime mortar in lime miller, scaffolding, watering and all coping work when handed over to be perfectly clean and free from all mortar stains etc. complete. |
| 27 | Making of moulding or carving on stone member, as per given design or drawing, by an expert, artisan craftsman, including light sand papering of the finished member if required. |
| 28 | Making of relief architectural carving on the surface of the stone member, as per given design or drawing, by an expert, artisan craftsman, including light sand papering of the finished member if required. |
| 29 | Providing & fixing SS Dustbins of the specifications as provided by the Conservation architect |
| 30 | Planting small and medium size ornamental/flowering plant:- Digging pit with size 0.6 m × 0.6 m x 0.6 m, Removing & conveying unwanted stuff to a required distance as directed. Filling the pit with fresh garden soil & Farm Yard Manure up to a height of 0.60 m in 3:1 proportion. Mixing soil and manure thoroughly well, leveling and watering previous night. Planting one or two year old healthy plant saplings as per specifications. Maintaining till well established by watering, Stirring of soil and manure, replacing of casualties etc. complete. |
| 31 | Planting large flowering/shady trees:- (Minimum Height to 2 Mtr.)Digging pit with size 0.9 m × 0.9 m x 0.9 m Removing & conveying unwanted stuff to a required distance as directed. Filling the pit with approved excavated material up to a hight of 0.30 m. and remaining height of 0.60 m. with fresh garden soil & manure in in 3:1 proportion. Mixing soil and manure thoroughly well, leveling, as directed, watering previous night. Planting one or two year old,minimum 1.0 mtr. mtr. hight, healthy tree sapling as per specifications. Maintaining till well established by watering, weedings, Stirring of soil, staking, replacing, casualaties etc |
| 32 | Providing and fixing of retro-reflectorised informatory sign board rectangular/Square in shape having area less than 0.9 One Square Meter rmade out of 4mm aluminum composite panel with 0.5mm skin thickness on either side bonded with white retro reflective sheeting of Class B (Type I V High intensity micro-prismatic grade sheeting HIP) having pressure sensitive adhesive retoreflective specified background, border and back side retoreflctive symbols, letters, numerals, arrowas per IRC:67- 2012 Table No8.3, supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with two coats of grey stovee name l paint and supported on one no. mild steel angle ironpost 75 mm x 75 mm x 6 mm, 3.5mt~3.9mt long firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45cmx45cmx60cm, 60cm below ground level as per approved drawing The angle iron post shall be duly painted with one coat of epoxyprimer and two coats of epoxy finish paints having alternate black and white bands of 25cm width including fixures and transportation etc. complete. The nut bolts of board with angle iron post/supporting structure after fixing at site has to be electrically welded. ClassB (Type IV High intensity micro-prismatic grade sheeting HIP) sheeting shall have 7 years written warranty from the manufacturer including the Digitally Printed areas with approved printing technology with sheeting manufacturer approved inks and laminated with UV overlay film and this warranty certificate along with sheeting manufacture rattested 3 years out door weathering test report from Indian govt lab must be submitted to the Engineer in charge by the contractor/supplier. |
| 33 | Providing Lime Pointing to stone work in lime mortar 1:1 in superstructure, as per detailed specifications and drawings or as directed including all face or visible work shall be pointed, unless otherwise specified and shall be done while the mortar is fresh, the mortar shall consists of lime and fine sand shall not be ground fine but sand should be finer, the joints of the pointed work shall be neatly defined by the pointing, the lines shall be regular and uniform in breadth and the joints shall be raised or flat as may directed, preparing the lime mortar with 640 gram pulp of wood apple (Belfruit) per cubic metre of lime mortar as a bonding material, scaffolding, watering and all work when handed over to be perfectly clean and free from all mortar stains etc. complete Please Enable Macros to View BoQ information |