| Sl. No. | Item Description |
| 1 | Percentage BoQ BoQ_Ver3.0 Percentage Normal INR Only INR Select, At Par, Excess (+), Less (-) IOCL Tender Inviting Authority :- EXECUTIVE ENGINEER PROVINCIAL DIVISION PWD B&R JALANDHAR Name of Work :- DNIT FOR THE ESTABLISHMENT OF NEW AAM ADMI CLINIC (AAC) AYUSHMAN AAROGYA KENDERAS IN URBAN AREA PHASE-X AT CHOGITTI IN JALANDHAR Contract No: Civil Works Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Work Name Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | A-1 ) CIVIL WORK |
| 3 | Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides oftrenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directedwithin lead of 30 metres. |
| 4 | Providing and applying Anti Termite Treatment using pre constructional chemical treatment measures as per IS - 6313 - 2001 ( Part 2 ) &using Chemical containg chloropyrifos systemic insecticide diluted to manufacturer's specifications (i) In foundation pits, by treating the bottom & sides upto height of 300mm by uniformly spraying solution @ 5 Litre / Sqm (ii) In the refill earth on both sides of all built up walls @ 7.5 Litre / Running meter ( width - 300 mm, depth - 450 mm ) (iii) Before laying the floor, by uniformly sprinkling the top surface of the consolidated earth within the outer perimeter @ 5 Litre solution per Sqm. |
| 5 | Cement concrete 1:5:10 With stone aggregate 40mm gauge mixing by mechanical means using concrete mixer volumetric type |
| 6 | First class burnt brick laid in cement sand mortar 1:6 in foundation and plinth |
| 7 | Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth. |
| 8 | Damp proof course 4cm thick of cement concrete 1:2:4 with water proofing compound as per manufactures guidelines. |
| 9 | Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure. |
| 10 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete |
| 11 | Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) |
| 12 | Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels. |
| 13 | Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. |
| 14 | First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level. |
| 15 | 12.5 mm thick cement plaster 1:5 |
| 16 | 12.5 mm thick cement plaster 1:4 |
| 17 | 20mm thick cement plaster 1:5 in two coat work |
| 18 | 20mm thick cement plaster 1:4 in two coat work |
| 19 | Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top ofR.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing |
| 20 | Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where speciallyspecified. |
| 21 | Top Khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50.00 thick cement concrete 1:8:16 |
| 22 | Bottom khurra on ground 1.2m 0.6m consisting of bricks on edge laid in cement mortar 1:3 over 7.5 cm cement concret 1:8:16 including 12.5mm thick cement plaster 1:3 |
| 23 | Providing and fixing 110 mm dia . U.P.V.C Rain water pipe of 4 kgf./sqm as per IS:4985 including jointing during masonary complete asper specifications and to the entire satisfaction of Engineer-in- charge |
| 24 | Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to theentire satisfaction of Engineer- in- charge.a UPVC 110 mm bend |
| 25 | Providing and fixing 110 mm dia. U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as perspecifications and to the entire satisfaction of Engineer- in- charge.a UPVC 110 mm bend |
| 26 | Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% taking outside the premises in 15 cm layers including ramming, watering and consolidated lead upto 1000 metres |
| 27 | Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres |
| 28 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 and with stone aggregate 40mm gauge and 100 mm fine sand filling using mechanical mixer for mixing of material |
| 29 | Providing and laying vitrified floor tiles of different sizes in light colour shades made using Double Charge technology (thickness to bespecified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours andshades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete.a Size 600x600 mm |
| 30 | Grouting the joints of flooring tiles having joints of 3 mm width, using 2mm to 3 mm gap using spacers and later this gap to be filled withcement based grout ) with Cement base grout and matching pigments etc., complete, including filling / grouting and finishing complete as perdirection of Engineer-in-charge.a Size 600x600 mm. |
| 31 | Marble stone flooring with 18-20 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thickbase of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with :(iv) Udaipur Green Marble Tiles of thickness 18mm to 20mm(b) Slabs sizes above 0.50 sqm |
| 32 | Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M-35 grade machine made rubber moulded smooth finish with strong vibratory process or with vibrohydrauliccompaction machine and of approved size and design / shape laid in Ordinary Grey and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in-Charge |
| 33 | Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS :15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 450 x 310 mm as approved by Engineer-in- Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement:4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shadecomplete. |
| 34 | Providing and Laying Out Door precast designer chequered tiles of any size & any shape 25mm thickness having top layer of white cement mixed with pigment, laid on 20mm thick bed of ordinary cement mortar 1:3 (1 ordinary cement: 3 fine sand), joints grouted with white cement slurry containing pigment to match the shade complete in all respect as per specifications and to the entire satisfaction of engineer-in-charge. |
| 35 | Providing and fixing mineral fibre false ceiling tiles at height upto 4 mtr. of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflection > 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge.i With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.6) size 595x595 mm |
| 36 | Supplying and fixing of GI sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standarddesign latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge.c) Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg per meter. |
| 37 | Providing & fixing of Box type steel windows, made of various ERW section outer 60mm x 25mm, central mullion 60mm x 25mm, for shutter 50mm x 20mm having thickness of 1.25mm (18 gauge), shash bar MS Tee 25mm x 3mm where required joints mitered and electrically flashwelded, with iron fittings including necessary iron handles, hinged cleat, tower bolts, iron hold fast and pintle hinges complete (excluding glazing and wire gauge) and finished with ready mixed paint red lead non setting primer complete as per specification, Drawings and to the entire satisfaction of engineer-in-charge. (Note:- Glazing, wire gauge and grill will be paid as per respective items) |
| 38 | Extra for providing & fixing Steel beading of approved shape steel tube beading size 12mm X 12mm, 18 gauge of approved shape and sectionwith screw for fixing of glass panes instead of glazing clips and metal slash putty in steel doors , windows & Ventilators complete in all respect |
| 39 | Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position |
| 40 | Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make.(b) Glass panes 4mm or 10.75 kg / sqm exceeding 0.4 sqm of area |
| 41 | Wire gauge fixed in steel windows, of standard rolled steel section with 3mm thick flat iron cover moulding of 12.5 mm width, fixed with machinescrews, complete in all respects. |
| 42 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In-Charge. (Glazing and paneling to be paid for separately) :(a) For fixed portion and chawkhats |
| 43 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In-Charge. (Glazing and paneling to be paid for separately) :(b) For shutters of doors, windows & ventilators including providing andfixing hinges/pivots and labour for fixing of fittings wherever requiredincluding the cost of PVC Plug / neoprene gasket required |
| 44 | Providing and fixing 12mm thick prelaminated particle board flat pressedthree layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in paneling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer-In-Charge. Prelaminated particle board with decorative lamination on one side. |
| 45 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete a) 300mm x 16mm: |
| 46 | Providing Polyester Powder coating 50 micron any coloured specified to alumnum section of various sizes including carriage of material frommarket to workshop & workshop to site of work. |
| 47 | Factory manufactured solid flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : IS 2202-1 (1999):(a) Commercial with elm or gurjan facing on both \ Sides withlaminated core and lipped edges:-(iv) 35mm thick |
| 48 | Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti including finishing the surface to required finish complete. |
| 49 | Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt)1) For shutter area up to 0.50 sqm |
| 50 | Providing & fixing 16 gauge stainless steel pipe railing of grade 304 duly fixed on steps with the help of bolts grouted on steps with hand rail andnewel post of 50mm dia Stainless steel pipe, Balusters of 40mm dia Stainless steel pipe and guard 3 Nos of 15mm dia Stainless Steel pipecomplete in all respect |
| 51 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish |
| 52 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give aneven shade |
| 53 | Finishing walls with acrylic smooth exterior paint of required shade with two or more coats applied @ 1.67 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
| 54 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concretesurface to give an even shade. |
| 55 | Chair for Reception- Providing and supplying medium back chair with ergonomic design, comfortable & aesthetically appealing. The seat and back shall be made of 15mm thick hot pressed commercial plywood padded with high resilience moulded polyurethane foam 50mm thick having density 40kg/m³ in seat and 40mm thick having density 40Kg/m³ in back. The same shall be upholstered with fabric tapestry 1mm thick and 300 GSM. The back and base of the chair shall be supplied with polypropylene bead on edges and the backrest shall be made by keeping the natural curvature of the spine with back support. The seat and back shall be arrested together with 50-60µ thick powder coated HR steel spine and the armrest shall be made of black integral metal insert polyurethane arm completely joint with seat and back. For seating durability the chair shall have swivel tilt 360 degree revolving mechanism with upright position locking and tilt tension adjustment. The pneumatic seat height adjustment for healthy seating, user can adjust seat height up to 100mm with BIFMA standard class-3 gas-lift to suit them using the lever under the seat. The gas-lift mechanism should be tested as per ANSI/BIFMA X5.1-2011 standard. The pedestal should have five legged injection moulded in black 30% glass filled nylon having pitch circle Dia. 650±15 mm and fitted with 5 nos. twin wheel castors. The castors of the chairs should be injection moulded in black 30% glass filled nylon, confirming to ANSI/BIFMA X5.1-2011 standard tested to perform 98,000 cycles with 250lbs load. The seat size shall be 460±10 mm(W) X 450±10 mm(D) and back size shall be 460±10 mm(W) X 400±10 mm(H) from seat. Seat height = 460±10 mm, overall height shall be = 810±10 mm. |
| 56 | Providing and fixing at site the pharmacy counter plan dimensions as 5'3\\" x 1' 10-1/2\\" and and High 2'6\\" with projection sheve, Storage Drers space for legs etc |
| 57 | Providing & Installation of SS Table of Top size 6'-6\\"x 2'-0\\" x 2'-6\\" High having provision of Lab sink complete as per Drawing & Specificaton as Desired by Engineer-in_ Charge |
| 58 | Providing & fixing ACP Sheets of various thickness High Class ISI marked complete in all respect as per the directions of Engineer-in-charge. |
| 59 | Writing matter on front signage Using high intensite Microprismatic grade retro reflective Sheeting type IV as per ASTM D 4956 09 and as per IRC 67 2012 |
| 60 | Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position |
| 61 | Providing and fixing Name Plates of Various size made of PVC sheet Printed with self adhesive tape pasted on sunboard complete as disired by Engineer-in Charge |
| 62 | B-2 )ELECTRICAL WORK |
| 63 | Providing Internal Electrical Installations: |
| 64 | RECESSED AIR CONDITIONER SUPPLY TERMINAL POINT (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): |
| 65 | Wiring air conditioner supply terminal point recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 25Amp. combined/ universal Socket (shuttered) and modular motor starter 25Amp. (2Module), covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 66 | Wiring AC supply terminal point having 1No. 25Amp. universal Socket (shuttered) erected at AC height and 1No. Motor starter 25Amp. erected at switchboard height. |
| 67 | RECESSED COMPUTER SUPPLY TERMINAL POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): |
| 68 | Wiring Computer supply terminal points recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10/16/20Amp. Switches and blanking plate etc., and covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 69 | Wiring Computer terminal point having 3 Nos. 6Amp. 2/3 universal socket (shuttered), 1No. 16 Amp. switch with indicator and 1No. blanking plate (Modular accessories). |
| 70 | RECESSED TV, TELEPHONE & NETWORKING SOCKETS OUTLET POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): |
| 71 | Supply and erection of TV socket, Telephone socket and Networking socket points in powder coated/anodized concealed metal boxes recessed in wall required for suitable number of modules (Modular accessories) for having TV sockets, Telephone sockets RJ11 & Networking socket RJ45 (one module), covered with Frame Plate and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 72 | Wiring Telephone socket point RJ11 (one module) |
| 73 | Wiring Networking socket point RJ45 (one module) |
| 74 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: |
| 75 | Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\\" deep for walls and CI 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 76 | Wiring fan point (With fan box) |
| 77 | Wiring light point |
| 78 | Wiring call-bell point |
| 79 | Wiring 6Amp. wall socket point |
| 80 | Wiring 6Amp. Plug control comprising wall socket point |
| 81 | Wiring 16/20Amp. power plug control point |
| 82 | PVC INSULATED FR COPPER CONDUCTOR CABLES: |
| 83 | Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 84 | Overall size 1.5sq.mm (Un-sheathed) |
| 85 | Overall size 2.5sq.mm (Un-sheathed) |
| 86 | Overall size 4sq.mm (Un-sheathed) |
| 87 | Overall size 10sq.mm (Un-sheathed) |
| 88 | XLPE INSULATED UN-ARMOURED CABLES (ON SURFACE): |
| 89 | Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:- |
| 90 | Overall size 10sq.mm (2Core) Un-armoured (On-Surface) |
| 91 | Overall size 16sq.mm (4Core) Un-armoured (On-Surface) |
| 92 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES: |
| 93 | Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- |
| 94 | Heavy Gauge PVC Conduit Pipe 25mm dia. (Flushed) |
| 95 | G.I. EARTHING: |
| 96 | Earthing with G.I. wire/ rope in G.I. pipe partly recessed and partly on surface complete with 150cm long 50mm dia. G.I. earth pipe (Cutting threads and 36 Nos. holes, 1cm dia. to make a mesh around the GI Pipe) with G.I. reducing socket including erection of the same, 4.50 metre (14.76 feet) below ground level with 20Kg. charcoal & salt mixture etc., up to 8 metre in length (including boring & refilling). |
| 97 | Earthing with 8 S.W.G. (4mm dia.) G.I. wire in 15mm dia G.I. pipe with G.I. reducing socket 50mm x 15mm (upto 8Metre in length) |
| 98 | Fixing additional length of earthing with G.I. wire/ rope in G.I. pipe (On Surface) with sockets, elbows and MS saddle clamps including painting etc. |
| 99 | Additional length G.I. wire 8 S.W.G. (4mm dia.) in 15mm dia. G.I. pipe (On Surface) |
| 100 | COPPER EARTHING:8 SWG COPPER EARTHING : |
| 101 | Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- |
| 102 | Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 4.50 metre (14.76 feet) below ground level (up to 8metre in Length) with G.I. pipe 20mm dia. (A-class), 3metre long |
| 103 | Fixing additional Length of earthing with 8 S.W.G. (4mm dia.) copper wire in G.I. pipe with sockets, elbows, steel hooks and GI saddle clamps including painting etc.:- |
| 104 | Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (On Surface) |
| 105 | MINIATURE CIRCUIT BREAKERS: |
| 106 | Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- |
| 107 | MCB Single Pole 6-32amp. (10kA, Curve-C) |
| 108 | MCB Double Pole 50, 63amp. (10kA, Curve-C) |
| 109 | SHEET METAL DOUBLE DOORDISTRIBUTION BOARD FOR MCB's/ RCBO's/ RCCB's: |
| 110 | Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color- coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:- |
| 111 | SP&N Double Door Distribution Board 12 way each |
| 112 | Supply and erection of sheet metal double door vertical distribution boards IP 43-IK09 metal door (dust protected) as per IS:8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars for each phase, 2 Nos. shrouded neutral bars, 2Nos. earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting MCCB's as incomer and outgoings SP/TP miniature circuit breakers in the distribution board as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc.:- |
| 113 | TP&N Double Door Vertical DB's 4 way each (With provision of FP MCCB upto 125amp) |
| 114 | MCCB's (FOR PANELS & SHEET ENCLOSURE): |
| 115 | Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader terminal links, Extended rotary handle and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:- |
| 116 | MCCB Four Pole 63/80/100amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting |
| 117 | Supply and erection of AC Ceiling Fan 1200mm (48\\")-3star suitable for 230 V single phase with double ball bearing, copper wound, full aluminium body 3Nos of blades, white in colour. The mounting type is down rod mount. The product should possess a minimum air delivery of 218 CMM. The rated speed of the the product must be minimum of 350 revolutions per minute and 5Nos. of speeds. The approximate weight of the product should be 4Kg and 180gms.(without packing) or higher. The product should have a manufcaturer's guarantee /warranty of minimum 2 years. The product should be complete in all aspects with fan motor, bladeset down rod, conopy set, shackle kit, twisted wire etc., including erection & testing of ceiling fan having connection with PVC insulated PVC sheathed two single core copper conductor (FR) cable 0.75 sq. mm complete in all respects as per satisfcation of the Engineer in-charge at site. |
| 118 | Supply and erection of Recessed Mounted 2FT X 2 FT 36 Watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including there drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No: AT/2021/GL/1410-1422, Dated: 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory. |
| 119 | Supply and erection of LED batten 40 Watt LED with High quality extruded aluminium with efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including there drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. LED Fitting as per pecifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No: AT/2021/GL/1410-1422, Dated: 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory. |
| 120 | Supply and erection of LED batten 20 Watt LED with High quality extruded aluminium with efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including there drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. LED Fitting as per pecifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No: AT/2021/GL/1410-1422, Dated: 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory. |
| 121 | Supply and erection of Slim Recessed mounted, Round downlighter 18 watt with Pressure die cast aluminium housing & polycarbonate diffuser with surge protection 10KV and efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 %, housing & driver shall be of same brand, supported with LM 79 reports not more than 2 years old from NABL /UL accredited laboratory complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. The certification and specifications of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory. |
| 122 | Supply and Erection of Venti Air Fan 250mm with louver shutter longer life including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the engineer in-charge at site. |
| 123 | Supply and Erection of Wall fan plastic body 400mm 16\\" including flexiible wire and petty material etc. for connection and testing complete in all respects as desired by the Engineer in charge of work at site. |
| 124 | Supply, erection Testing and Commissioning of Token Calling Display System having screen size 4 inches, Voice calling with Bell System, complete key pad Etc, calling display up to 60 meter cable (15 meter length included), serial communication design, Text Color Red Display Shape Rectangle,Power 5 W,Sound Type Mono Display Technology 7 Segment Voltage 220-240 V AC Suitable for Clinic, Hospital,Cash counter, Tehsil, Courtsetc, Warranty 1 Year,220 VAC Operating Voltage Character Capacity 3 Character, Power Consumption,Rectangular Metal body complete in all respect as desired by the engineer in charge at site. |
| 125 | Supply, erection, testing and commissioning of pure sine wave inverter 2000VA with 24 month warranty with Trolley for two tall tubular batteries, connections and testing etc. complete in all respect as approved and desired by the engineer incharge at site. |
| 126 | Supply, erection, testing and commissioning of 12 Volt. 200 AH Tall tubular battery with warranty 36 months including connections and testing etc. complete in all respect as approved and desired by the engineer incharge at site. |
| 127 | Supply and erection of New Generation 45w LED street light with pressure die-cast housing, high performance polycarbonate optics and IP66 ingress protection. Top openingdriver cover for easy maintenance. E cacy 120 lm/W. complete in all respects as approved and desired by the Engineer-in-charge at site. LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No: AT/2021/GL/1410-1422, Dated: 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory. |
| 128 | SINGLE ARM BRACKETS FOR GI PIPE POLE: |
| 129 | Supply and erection of G.I. Pipe 40mm dia. (A-class) Single arm bracket of suitable length give a total overhang at a tentative angle of 100/105º, the bracket should be fixed on the top of the GI pipe pole having top outer dia. 80mm/100mm with GI reducer of suitable size with two coats of an approved aluminium paint complete in all respect as approved by the Engineer-in-charge at site:- |
| 130 | Single Arm Bracket 1 metre Long with G.I. Reducer 80mm x 40mm |
| 131 | SHEET METAL IRON CLAD CHANGEOVER SWITCHES: |
| 132 | Supply and erection of sheet metal Iron Clad Changeover Switch on existing surface with G.I. bolts & nuts/rag bolts and nuts etc., according to the size of holes in the body of the switch including connections with suitable size of thimbles and bonding to the existing earth as per PWD General Specifications:- |
| 133 | ICDP Changeover Switch 63amp., 415volts |
| 134 | Supply and erection of SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772 (Recessed/ On surface), robustly constructed, safe & shock proof, rust & tamper proof of suitable inner & outer dimensions with ± 10% tolerance in size & hinged water tight cover with locking arrangement having 1No. terminal strip with 4Nos. terminals & 1No. Single pole MCB of required capacity fixed on din bar (Din Bar Provision for 2Nos. MCB's) complete in all respect as approved and desired by the Engineer In-Charge at site:- |
| 135 | SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772, inner dimensions 140mm x 140mm x 95mm with hinged water tight cover with locking arrangement |
| 136 | Networking System :- |
| 137 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES: |
| 138 | Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- |
| 139 | Heavy Gauge PVC Conduit Pipe 25mm dia. (Flushed) |
| 140 | Copper conductor cables for special elecrtrical services |
| 141 | CAT 6 LAN Cable |
| 142 | Supply & erection of CAT 6 TWO Meter long Patch Cord Having RJ-45 Male Connectors on both ends DCC up-to 10/100/1000 mbps.complete in all respect as desired by the engineer in charge at site. |
| 143 | Supply & erection of 6U Wall mount 19’’ Rack with glass door,lock & key facility 400/450/500mm depth AC Fan having 10 no. mounting hardware, Cable entry/exit provision at top and bottom panels, Ventilation slots on top, bottom and side panels, Fixed side panels, Comply IS Standard of Racks complete in all respect as approved and desired by engineer incharge at site. |
| 144 | Supply & installation of 8 Port 10/100/1000 Mbps Unmanaged Data switch having IEEE 802.3 10BASE-T Ethernet, IEEE 802.3u 100BASE-TX Fast Ethernet, IEEE 802.3ab 1000BASE-T Gigabit Ethernet, IEEE 802.3z Gigabit Ethernet, IEEE 802.3x Flow Control, 802.1p priority, Energy Efficient Ethernet, Switching capacity 36 Gbps, HOL blocking prevention, 802.1p priority based, hardware queues, priority queuing and Weighted Round-Robin (WRR) Jumbo frame Each complete in all respect as approved and desired by the engineer incharge at site. |
| 145 | Supply &erection of 1000VA LIT UPS/ Power Plant with SMF batteries having 30 Minutes backup time, Cold Start, 3 No. plug Indian style, Automatic Voltage Controller, Overload protection, Over charging Protection, 2 No. 12v 7Ah Batteries, Wide Input Range, Fan Less Cooling system, Transfer time less than 8ms,Audible Alarm etc.complete in all respect as desired by the engineer in charge at site. |
| 146 | Supply & Installation of intercom facility 1+1 Basic Plan Phone Ringer volume control switch Tone/ Pulse Switchable Redial Mute Flash Pause Intercom facility Call T, Holding the line / Music on Hold during call transfer Line use LED Indication, Secrecy during conversation between both phones, including connecting cables complete in all respect as approved and desired by the Engineer in-charges at site. |
| 147 | C-3 ) PUBLIC HEALTH WORK |
| 148 | Sub Head-1 Internal Water Supply System |
| 149 | CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge. |
| 150 | b) CPVC SDR 11 Pipe & fitting 20mmo/d |
| 151 | c) CPVC SDR 11 Pipe & fitting 25mmo/d |
| 152 | EXTERNAL IN THE GROUND : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI markedwith the prior approval of Engineer-inCharge), having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, & testing of joints excluding cost of excavation complete as per direction of Engineer-in-Charge |
| 153 | b) CPVC SDR 11 Pipe & fittig 20 mmo/d |
| 154 | c) CPVC SDR 11 Pipe & fittin25 mmo/d |
| 155 | d) CPVC SDR 11 Pipe & fitting 32mmo/d |
| 156 | Excavation in trenches with straight or open cutting in streets, lanes or in open area with 3D/JCB or excavator including manually dressing bed, trimming sides and side slopes for sewers and manholes to full depths as shown in drawings,including, dressing to correct sections and dewatering, provision for diversion for traffic, protection of existing services i.e. telephone cables, electric lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, watching, etc., fixing and maintenance of caution boards, fencing, refilling trenches, watering, ramming and restoration of surface to original level and removal of surplus spoil from the site of works, upto one chain (15m) complete in all respects. |
| 157 | Depth not exceeding 3 m. BGL |
| 158 | Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes line and making good the same to its original condition.Size 75mm x 75mm |
| 159 | qty same as CPVC P 20mm +25 mm |
| 160 | Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required. |
| 161 | Through wall 11.43 cm thick |
| 162 | Through wall 22.86 cm thick |
| 163 | Providing, fixing and jointing Brass Ball valves screwed with SS/BRASS ball & spindle & Teflon seats, on G.I. Pipe lines including all carriages complete. |
| 164 | 20mm i/d Brass Ball valves |
| 165 | 25mm i/d Brass Ball valves |
| 166 | 32mm i/d Brass Ball valves |
| 167 | Making connection with the existing G.I. branch main up to 40mm size pipe including cutting of existing pipe line, threading of pipe lines from both ends and fixing of G.I Tee etc. in the pipe line (including cost of G.I Tee) complete in all respects. |
| 168 | Sub Head-2 Internal & External Sewerage System |
| 169 | Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonagepipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. |
| 170 | Single Socket Type B |
| 171 | b) 110mm o/d SWR UPVC pipe lines laid complete |
| 172 | Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining. |
| 173 | For 110mm o/d pipes |
| 174 | ii)Single Tee With Door |
| 175 | iii) Single Tee |
| 176 | iv)Door Elbow 90 Degree |
| 177 | v) Elbow 90 Degree (all side socketed) |
| 178 | viii) Coupler |
| 179 | ix) P Trap/Floor Trap 110mm x 110mm |
| 180 | xi) Single Y-Junction |
| 181 | Elbow 45 degree |
| 182 | Providing PVC solvent cement joints to SWR Pipes and specials including cost of PVC solvent cement and tools etc of approved make (to the approval of Engineer-in-charge ) |
| 183 | 110mm o/d |
| 184 | Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50mm |
| 185 | 100mm internal Diametre S.W.gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm |
| 186 | Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design. |
| 187 | 450mm x 600mm inside with 455mm x 610mm cover and frame light duty double seal |
| 188 | Cement concrete 1:2:4 |
| 189 | a With stone ballast or shingle |
| 190 | mixing by mechanical means using concrete mixer volumetric type |
| 191 | Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects. Size 160mm o/d |
| 192 | Sub Work-3 Civil work, Flooring and Wall Tile |
| 193 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 and 100mm sand filling using mechanical mixer for mixing of material |
| 194 | Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS :15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black ofsize 600 x 300 mm as approved by Engineer-inCharge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 195 | Providing and laying Anti skid Ceramic floor tiles of size 300x300 mm x 10 mm thick of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on flooring skirting and dado in 12.5mm thick cement plaster 1:3 in base and jointed with @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., completewhite cement slurry in joints including corners angles and beading. |
| 196 | Sub Head-4 Sanitary Installation |
| 197 | Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI marked,PVC short bend32 mm dia including cost of seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge |
| 198 | Providing and fixing jet spray with 2'-6\\" long PVC pipe |
| 199 | With C.P. Brass nut |
| 200 | Providing and fixing in position premium range C.P. Brass Fittings and accessories of approved make (to the approval of Engineer-in-charge ) complete in all respect. |
| 201 | C.P. Brass Pillar Cock foam flow |
| 202 | Providing and fixing in position towel rails / ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect. |
| 203 | C.P. brass towel Rails size 15mm dia 610mm long |
| 204 | C.P brass towel ring |
| 205 | Providing and fixing in position C.P. brass soap dish of approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in allrespect |
| 206 | Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with rawl plugs 50mm, C.P. brass screws and washers and S/S Studs on top complete in all respect (as required by the Engineer-in- Charge) |
| 207 | Size 600mmx450mm |
| 208 | Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect |
| 209 | C.P. brass Bib cock long nose/long body foam flow without flange |
| 210 | C.P. brass Bib cock foam flow without flange |
| 211 | Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect |
| 212 | PVC tube connection of size 15 mm x 450 mm with C.P. Brass nut |
| 213 | Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect. |
| 214 | Providing & Fixing in postion stop cock / Angle valve of approved make (to the approval of Engineer-in-charge ) complete in all respect |
| 215 | C.P.brass 15mm Concealed stop cock with flange. |
| 216 | C.P.brass 15mm Angle valve without flange |
| 217 | Providing and fixing in position automatic brass Ball Cock intanks. iii)25mm i/d |
| 218 | Providing and fixing in position G.I. Tank Nipple of approved make (to the approval of Engineer-in-charge) in PVC Water storage tanks complete in all respect. |
| 219 | G.I. tank nipple 20mm i/d |
| 220 | G.I. tank nipple 25mm i/d |
| 221 | Providing, fixing and jointing G.I Union Couplings(of approved make with the approval EIC) as per IS 1879 in G.I. Pipe lines complete in all respect. |
| 222 | 20mm i/d G.I. Union |
| 223 | 25mm i/d G.I. Union |
| 224 | Providing & Fixing in position C.P. Brass flange Dome of approved make (to the approval of Engineer-in-charge ) under various fixtures complete in all respect. |
| 225 | Providing & Fixing in position C.P. Brass extension piece 25mm long to 100mm long of approved make (to the approval of Engineer-in-charge )with various fixtures complete in all respect. |
| 226 | C.P. Brass extension piece, 25mm long to 50mm long |
| 227 | Providing & Fixing in postion liquid soap container of approved make (to the approval of Engineer-in-charge ) complete in all respect. |
| 228 | acrylic liquid soap container |
| 229 | Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer - in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. |
| 230 | Construction of Plateform complete as per specification & as desired by Enginer-in-charge |
| 231 | Providing & Fixing in position C.P. Brass Hexa Nipple 15mm of approved make (to the approval of Engineer-in-charge ) complete inall respect. |
| 232 | Providing and fixing in position SS Gratingwith frame of approved make (to the approval of engineer in charge) complete in allrespects |
| 233 | Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge)including Rack Bolt Screw Pair 115mm long without CP fittings complete in all respect. |
| 234 | Size 630 mm x 450 mm x 830 mm |
| 235 | Providing and fixing vitreous chinaware pedestal of approved make (to the approval of Engineer-in-charge) for wash hand basin complete in all respect. |
| 236 | Vitreous chinaware standard white pedestal for wash hand basin. |
| 237 | Providing & fixing in position Water Cooler without Stablizer of approved make (to the approval of Engineer-in-charge ) includingcarriage complete in all respect. |
| 238 | Water Cooler Full Steel Body 40/80 ltr Capacity without Stablizer |
| 239 | Providing & fixing in position Commercial RO without reservoir with four no cartridge/membrane having flow rate 50 ltr/hr with 6stage purification process of approved make (to the approval of Engineer-in-charge ) including carriage and fixing in positioncomplete in all respect. |
| 240 | Providing & fixing in position Water Dispenser Top Loading (with refrigration capacity 15 ltr) of approved make (to the approval of Engineer-in-charge ) dispensing hot/cold/ambient water including cost of two no. 20 ltrs packaged drinking water bottles and carriage complete in all respect. |
| 241 | Providing & fixing in postion C.P. brass Sink Cock with swinging spout (wall mounted) of approved make (to the approval of Engineerin-charge) complete in all respect. |
| 242 | Providing and fixing in position vitreous Chinaware white lIndian make large flat back or angular lipped front urinal 375 x 390 x 590mm of approved make (to the approval of the Engineer-in-charge) consisting of C.P. brass Urinal waste Coupling dome type 32mmouter length 75 mm , C.P. brass Urinal Spreader Ocular-Regular and C.P. brass tube connection 300 mm long complete. |
| 243 | Sub Head-5 Fire Fighting System |
| 244 | Providing and fixing of FIRE EXTINGUISHER, CO2 type as per IS: 15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect. |
| 245 | 4.5 Kg. Capacity |
| 246 | Providing and fixing of FIRE EXTINGUISHER, ABC Powder type (stored pressure) as per IS: 15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect. |
| 247 | 6 Kg. Capacity |
| 248 | Sub Head- 6 Air Conditioner |
| 249 | Providing & Installing 3 Star split type wall mounted air conditioner capacity 2.0 tonne with arrangement for installing OD units including connection of inlet and outlet copper tubes (Rate is inclusive of copper pipe 6.00mtrs and cable upto 8.00mtrs length ) with proper insulation, cable link between ID unit and OD units stand for OD unit and concealing of Copper pipes and drainage pipe within building and installing charges complete in all respects |
| 250 | Providing & Installing 3 Star split type wall mounted air conditioner capacity 1.5 tonne with arrangement for installing OD units including connection of inlet and outlet copper tubes (Rate is inclusive of copper pipe 6.00mtrs and cable upto 8.00mtrs length ) with proper insulation, cable link between ID unit and OD units stand for OD unit and concealing of Copper pipes and drainage pipe within building and installing charges complete in all respects |
| 251 | Providing & Installing 3 Star split type wall mounted air conditioner capacity 1.0 tonne with arrangement for installing OD units including connection of inlet and outlet copper tubes (Rate is inclusive of copper pipe 6.00mtrs and cable upto 8.00mtrs length ) with proper insulation, cable link between ID unit and OD units stand for OD unit and concealing of Copper pipes and drainage pipe within building and installing charges complete in all respects |
| 252 | AUTOMATIC VOLTAGE STABLIZER: |
| 253 | Supply and erection of Single phase copper wound Automatic voltage stablizer of suitable capacity electronically controlled circuit with input voltage 140-260 volts single phase AC supply and output voltage 220 ± 5% volts single phase AC supply having main silicon core copper wound step up transformer with suitable nos. of turns on primary side and secondary side the transformer should be fully insulated inside the MS sheet box of suitable size. There should be power control relay and single pole MCB (C-curve, 10kA) of suitable capacity complete with internal copper wiring along with amp. meter and volt meter, high voltage cut off 280 volt input (240 volt output) and 90 volt maximum boost and overloading protection to be provided:- |
| 254 | Automatic Voltage Stablizer 2 KVA |
| 255 | Automatic Voltage Stablizer 5 KVA |
| 256 | Automatic Voltage Stablizer 4 KVA |
| 257 | Providing, laying, jointing, fixing and testing uPVC Pipe with G.I. specials as per ISI-4985, including cost of G.I. specials such as tees, bends, sockets, elbows etc. testing inside building complete. |
| 258 | 25mm i/d |
| 259 | For 2.00 tonne split AC |
| 260 | For 1.00 tonne split AC Total in Figures 3725855.0 3725855.0 INR Thirty Seven Lakh Twenty Five Thousand Eight Hundred & Fifty Five Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 INR Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail