| 1 | Demolition of brick or stone masonry work built in cement mortar including all quoins, arches, pillars etc complete all as specified and as directed. |
| 2 | M&L for brick work with sub class ‘B’ bricks (locally available best quality) straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 complete all as specified and as directed. |
| 3 | M&L for brick work with sub class ‘B’ bricks (locally available best quality) straight or curved on plan any radius in half brick thick wall, built in cement mortar (1:4) complete all as specified and as directed. |
| 4 | Taking down cement plaster on walls, chajja surfaces, etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed. |
| 5 | M & L for rendering 10 mm thick in cement mortar (1:6) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed. |
| 6 | M&L for 15mm thick rendering in cement mortar (1:4) on fair faces of brick or concrete wall surfaces, finished even and smooth without using extra cement complete all as specified and as directed. |
| 7 | M&L for preparation of newly plastered surface of walls and applying two coats of oil bound distemper over a coat of primer complete all as specified and as directed. |
| 8 | M&L for preparation of newly plastered surface of walls and applying two coat of cement base paint over a coat of primer complete all as specified and as directed. |
| 9 | S&F for 4mm thick, plywood (No. of ply3), grade BWR,type BB, fixed with nails to timber frame work on wall including taking out old plywood of any description complete all as specified and as directed. |
| 10 | S&F for 4mm thick , veneered decorative plywood (No. of ply3), grade 1 (with BWR resin) with decorative face veneers on one face; fixed with nails to timber frame work on wall including taking out old plywood of any description complete all as specified and as directed. |
| 11 | S&F suspended false ceiling using E-grid 2430, 180 GSM (exposed ceiling suspension system ) of grid size 605mmx605 mm with main runner 38 mm x 24 mm and wall angle 24mm x 24mm using 4mm thick High Pressure stean Crude Everest Non Asbestos Fiber Cement plain Board (E-Board Classic) in & including a grid of GI system duly suspended with 4mm dia GI wire hanger fixed with providing positions for light fixtures,air conditioning diffuser and ducts ,sprinkler ,smoke detectors etc.The main runners to be secured to structural soffits by hanger @ 1220 mm maximum c/c. the last hanger at the end of each main runner should not be placed at more than 450mm from the adjucent wall,Flush fitting 1220 mm cross tee to be interlocked between main runners @ 610mm c/c,so as to form 605mm x 605 mm grid including taking out old ceiling of any description complete all as specified and as directed. |
| 12 | M&L for 2nd class clean swan hardwood plain fillets secured with nails or brads, area exc 13Sqcm and n exc 25Sqcm including dismantling of old fillet complete all as specified and as directed. |
| 13 | M&L for 2nd class clean swan hardwood plain fillets secured with nails or brads, area exc 6Sqcm and n exc 13Sqcm including dismantling of old fillet complete all as specified and as directed. |
| 14 | M&L for 2nd class hard wood, in scantlings, clean sawn timber as in un framed work and including dismantling of old one complete all as specified and as directed. |
| 15 | M & L for preparation of new wood or wood based surface of any description exceeding 10 cm width or girth and applying two coats of synthetic enamel paints over a coat of pink primer complete all as specified and as directed. Please Enable Macros to View BoQ information |