| Sl. No. | Item Description |
| 1 | Dismentaling Brick or stone masonary in lime or cement mortar under 3m height including stacking the |
| 2 | Earth work excavation of foundation in hard soil with all leads and lifts including dressing the sides and levelling the bed of foundation including cost of all labour required for the work etc complete with all other T&P required for the work and stacking the excavated materials away from working area as directed by the Engineer-in-charge including 1% cess. |
| 3 | Ground Floor |
| 4 | Supplying and filling in foundation and plinth with sand well watered & rammed with cost ,conveyance, royality & taxes of all materials and labour required for the work as per specification and including 1% cess as per direction of the Engineer-in-Charge. |
| 5 | Ground Floor |
| 6 | Filling in foundtaion and plinth with excavated materials including watering and ramming as directed by the Engineer-in-charge. |
| 7 | Ground Floor |
| 8 | Earth work for site development with approved material obtained from borrow pits with all lifts and leads, transporting to site by mechanical means within a lead of 5kms, spreading, grading to required slope and compacting to meet requirement |
| 9 | Approach Road |
| 10 | Cement Concrete of proportion(1:3:6) in foundation and plinth using 4cm size clean hard black granite metal of approved quality from approved quarry including hoisting, lowering and laying in layers not exceeding 15cm thick to the required level, ramming watering and curing etc.complete including cost, conveyance, royalty taxes of all the materials required for the work with all labour, T&P and cess etc. complete in all respect as per specification and direction of the Engineer-in-charge. |
| 11 | Ground Floor |
| 12 | Cement concrete work (1:2:4) using 12 mm to 20 mm size black hard crusher broken granite stone chips of approved quality from approved quarry including hoisting,lowering , laying and compacting concrete watering and curing for 28 days including finishing the exposed surface including cost , conveyance, royalties and taxes of all the materials and cost of all labour, T&P required for the work etc. complete in all respect including 1% cess as per direction of the Engineer-in-charge. |
| 13 | Ground Floor |
| 14 | Fly Ash brick masonary in C:M (1:6) using 25cmx12cmx8 cm size bricks having crushsing strength of not less than 75 Kg. per sq.cm. including splays cutting, circular, mouldings, and corbelling , champhering and similar such type of work , watering and curing etc . complete including cost , conveyance, royalities and taxes of all materials and cost of all labour with T&P required for the work etc. complete including 1% cess and as per the specification as directed by the Engineer-in-charge. |
| 15 | In Foundation and Plinth |
| 16 | Ground Floor |
| 17 | R.C.C. M-25 grade having a minimum compressive strength ( in work test ) 200 kg/ sq. cm in 15 cm cubes at 28 days after mixing and tests conducted in accordance with I.S 456 and I.S 516 using 20 mm and down graded size black hard crusher broken granite chips of approved quality from approved quarry including hoisting, lowering , laying and compacting concrete , watering and curing for 28 days, centring, shuttering , finishing the exposed surface including ceiling smooth, providing grooves , beads where necessary and providing required no of fan hooks as directed including cost, conveyance, royalities and taxes of all the materials and cost of all labour, T&P required for the work etc. complete in all respect including 1% cess as per direction of the Engineer in charge but excluding the cost of M.S rods or Tor steel and binding wire and labour charges for bending, binding and tying the grills as per specification and direction of the Engineer-in-charge. |
| 18 | Column base |
| 19 | Ground Floor |
| 20 | Column |
| 21 | Ground Floor |
| 22 | First Floor |
| 23 | Second Floor |
| 24 | Ground Floor |
| 25 | First Floor |
| 26 | Second Floor |
| 27 | Plinth beams |
| 28 | Ground Floor |
| 29 | Lintels |
| 30 | Ground Floor |
| 31 | First Floor |
| 32 | Second Floor |
| 33 | Window Sill |
| 34 | Ground Floor |
| 35 | First Floor |
| 36 | Second Floor |
| 37 | Chajja |
| 38 | Ground Floor |
| 39 | First Floor |
| 40 | Second Floor |
| 41 | Roof Slab |
| 42 | Ground Floor |
| 43 | First Floor |
| 44 | Second Floor |
| 45 | Stair case |
| 46 | Ground Floor |
| 47 | First Floor |
| 48 | Cutting, Straightening the bend up M.S./Tor Rods bending, binding welding, jointing if necessary and tying the grills and placing in position as required for R.C.C. works and for providing required no of fan hooks hoisting , lowering, laying including cost,conveyance and taxes of M.S. Rods or Tor steel and binding wires of 18 to 20 guage required for the work bending, binding and tying the grills in all floors ( payment will be made on weight of M.S. rods or Tor steel only and no separate payment will be made towards the weight of binding wires) including 1% cess as per direction of the Engineer-in-charge. |
| 49 | Ground Floor |
| 50 | First Floor |
| 51 | Second Floor |
| 52 | Fly Ash brick masonary in C:M (1:6) using 25cmx12cmx8 cm size bricks having crushsing strength of not less than 75 Kg. per sq.cm. including splays cutting, circular, mouldings, and corbelling , champhering and similar such type of work , watering and curing etc . complete including cost , conveyance, royalities and taxes of all materials and cost of all labour with T&P required for the work etc. complete including 1% cess and as per the specification as directed by the Engineer-in-charge. |
| 53 | In Super structure |
| 54 | Ground Floor |
| 55 | First Floor |
| 56 | Second Floor |
| 57 | Providing 6mm thick cement plaster in cement mortar of mix (1:4) at all height using screen and washed sharp river sand for mortar with approved quality of cement to the ceiling of the roof slab, staircase,beams,columns,Landings,Railings,chajja,fins,walls,jally and shelves etc. including roughening,scarping,chiseling,cleaning,closed deep chipping with slurry treatment and finished smooth to all RCC surface including cost, of all labour,lebour cess,sundries, T&P, Scaffolding, Watering,Curing etc.complete in all respect as directed by the Engineer-in-charge. |
| 58 | Ground Floor |
| 59 | First Floor |
| 60 | Second Floor |
| 61 | 16 mm thick cement plaster in C.M. (1:6) over brick masonry finished smooth after racking out of the joints including watereing and curing with cost, conveyance, royality and taxes of all materials and cost of all labour and T&P required for the work including 1% cess as directed by the Engineer-in-charge. |
| 62 | Ground Floor |
| 63 | First Floor |
| 64 | Second Floor |
| 65 | 12 mm thick cement plaster in C.M. (1:6) over brick masonry finished smooth after racking out of the joints including watereing and curing with cost, conveyance, royality and taxes of all materials and cost of all labour and T&P required for the work including 1% cess as directed by the Engineer-in-charge. |
| 66 | Ground Floor |
| 67 | First Floor |
| 68 | Second Floor |
| 69 | 20mm thick grading plaster in CM (1:6) with WO compound etc. complete |
| 70 | First Floor |
| 71 | Second Floor |
| 72 | Providing and fixing vitrified tiles in floors, treads of steps and landing on 20mm th bed of cement mortar (1:4) (1 cement:4 sand) joined with neat cement slurry mixed with pigment to match the shade of tiles including rubbing, polishing including cost of tiles, conveyance, taxes & labour, T&P and cess etc. complete in all respect as per specification and direction of the Engineer-in-charge |
| 73 | Ground Floor |
| 74 | First Floor |
| 75 | Providing & fixing Ceramic floor tiles in floors treads or steps and landing on 25mm thick bed of cement mortar 1:1 (1cement : 1sand) jointed with neat cement slury mixed with pigment to match the shades of the tiles including cleaning complete |
| 76 | Ground Floor |
| 77 | First Floor |
| 78 | Supplying, fitting and fixing virified colour printed series tiles in floors of size 300mm x 300 mm of approved make confirming to IS:13755 laid on 20 mm thich cement morter(1:4) (1 cement: 4 course sand) and filling joints with white cement of approved quality including cost of all materials, labour T&p etc. required for the work all complete as per direction of the engineer in charge (for new work only) |
| 79 | Ground Floor |
| 80 | Second Floor |
| 81 | Fixing Granite tiles in floors treads or steps and landing on 25mm thick bed of cement mortar 1:1 (1 cement : 1 sand) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing compelte including cost of pre-caste tiles |
| 82 | Ground Floor |
| 83 | Providing & fixing vitrified tiles in dados skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shade of the tiles including cleaning complete. |
| 84 | Ground Floor |
| 85 | First Floor |
| 86 | Second Floor |
| 87 | Providing & fixing glazed ceramic tiles in dados skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shade of the tiles including rubbing and polishing complete. |
| 88 | Ground Floor |
| 89 | First Floor |
| 90 | Providing and fixing glazed tiles in dados, skirting and rises of steps on 12mm thick cement plaster (1:3)(1cement:3sand) joined with neat cememnt slury mixed with pigment to match the shade of tiles, rubbing,polishing including cost of tiles conveyance,taxes &labour T&P and cess etc. complete in all respect as per specification and direction of Engineer in charge. |
| 91 | Ground Floor (Toilet block) |
| 92 | Supplying fitting fixing with decorative wirk Flush door including cost convency and taxcess of all materials |
| 93 | Ground Floor |
| 94 | First Floor |
| 95 | Providing wall panneling with century /sylvan 19mm /12mm ply IS303(BWR) and 4mm thick century veener Tino,century veener American maple including melamine polishing and cost covency royalty and taxes of all materials ,hair charges and cost of all labour T&P requred for the work complete in all respect as per the direction of Engineer in Charge. |
| 96 | Ground Floor |
| 97 | First Floor |
| 98 | Providing fitting fixing of aluminium anodised T sections no 3215 with 2\\" center to center ,L section no 175 up to 15 micron on 4 wall to be fixed by means of steel screw and PVC plug and the aluminium grid 2' 0\\"x 2' 0\\" suspended from celling etc. complete. |
| 99 | Ground Floor |
| 100 | First Floor |
| 101 | Supplying & fixing 30mm thick FRP door shutter with FRP frame including all hardware fittings etc. comp.Rate as per Local Market |
| 102 | Ground Floor |
| 103 | First Floor |
| 104 | Supplying,fitting and fixing of two track UPVC sliding window of approved make with 6mm thick glass of approved quality complete with fframe, shutters and all fitting and fixtures. ( shedule of rate page 235,sl no 12) |
| 105 | Ground Floor |
| 106 | First Floor |
| 107 | Supplying, fitting, fixing up window /Ventilator (sliding type) made up aluminium section 151-154, 151-155,aswindow frame Section No. 151-155, 151-153 and 151-167 as shutter frame with 5mm thick black glass as pannel fitted with rubber beading including locking arrangement including all fitting including cost of materials all taxes of labour, T&P etc. complete asper direction of E.I.C |
| 108 | Ground Floor |
| 109 | First Floor |
| 110 | Providing and fixing 5mm thick frosted glass for louver ventilators etc. complete |
| 111 | Ground Floor |
| 112 | First Floor |
| 113 | Providing and making structural glazing including back up frames etc. complete |
| 114 | Ground Floor |
| 115 | First Floor |
| 116 | Supplying and Fixing of M.S. Grills, M.S.Doors, M.S. Gate etc including cost,conveyance of all materials,priming,and labour for fitting fixing etc.complete as per the instruction of Engineer-in-Charge |
| 117 | Ground Floor |
| 118 | First Floor |
| 119 | Second Floor |
| 120 | Finishing surface of walls with cement base wall puty(Water based)of approved make and finished smooth and even surface to receive painting including cost of scaffolding, staging charges with cost of all materials taxes, lobour T&P and cess etc. |
| 121 | Ground Floor |
| 122 | Finishing wall surface with Acrylic wall putty(Water based) of approved make and finishing smooth and even surface to receive painting including cost of scaffolding,staging charges with cost of all materials labour t&p and cess etc. |
| 123 | Ground Floor |
| 124 | First Floor |
| 125 | Second Floor |
| 126 | Weather coat two coats including cost, conveyance, taxes of all materials all labour and T & P required for the work etc complete including 1% cess as per direction of the Engineer in charge. |
| 127 | Ground Floor |
| 128 | First Floor |
| 129 | Second Floor |
| 130 | Painting two coats with synthetic enamel paint over a coat of primer to iron work of approved quality and approved shade confirmming to ISI on steel work to give an even shade in all floors at all height over a coat of primer of approved quality and shade including sand papering and making the surface smooth with cost, coveyance, loading and unloading, of all materials, cost of all labour, sundries, T&P, scaffolding etc. required for the work and complete in all respect as directed by Engineer-in-charge. |
| 131 | Ground Floor |
| 132 | First Floor |
| 133 | Second Floor |
| 134 | Providing and applying French Polishing two coats to wood works etc.complete |
| 135 | Ground Floor |
| 136 | First Floor |
| 137 | Providing & fixing stainless steel railing with stainless steel square bar balusters etc. complete |
| 138 | Ground Floor |
| 139 | First Floor |
| 140 | Providing and fixing 110mm dia PVC rain water down pipe etc. complete |
| 141 | Ground Floor |
| 142 | Wall painting two coats with Acrylic paint (plastic emulsion) of approved quality of premium brand approved quality and colour at all height to the interior surface of the wall to make an even finished surface including sand paper applying putty wherever necessary including cost conveyance loading,unloading,stacking,all taxes,cost of labour,lobour cess,scaffolding,staging,sundries T&P etc. Required for the work complete as directed by the Engineer-in-charge. |
| 143 | First Floor (Garage) |
| 144 | First Floor |
| 145 | Second Floor |
| 146 | Wall priming one coat with approved primer with brush to wall surface including all cost, conveyance, taxes of all the materials , all labour and T&P required for the work etc. complete including 1% cess as per direction of the Engineer-in-charge. |
| 147 | Ground Floor (Toilet Block) |
| 148 | Distempering two coats to wall with approved distemper of approved shade ncluding cost, conveyance and taxes of all the materials, labour etc complete including 1% cess as per specification and direction of the Engineer-in-charge. |
| 149 | Ground Floor (Toilet Block) |
| 150 | Finishing walls with water proofing cement paint of approved shade on new work two coats to give an even shade with cost, conveyance, taxes of all the materials required for the work and labour, T&P and cess etc. complete in all respect as per specification and direction of the Engineer-in-charge. |
| 151 | Ground Floor (Toilet Block) |
| 152 | Providing and fixing Ultra Floor External Tiles size 300x300mm of use in Parking Floor and Skirting (thickness to be specified by the manufacturer) for any similar locations where ever required in horizontal/vertical surfaces of required size of approved shade, colour and texture edge etc. laid over 25mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand) with joints treated with epoxy touch ups including rubbing, curing, etc. complete as per direction of Engineer-In-Charge at all floors and all heights. |
| 153 | Ground Floor(Garage+parking ) |
| 154 | Providing laying R.C.C. Hume pipe NP3 class for culverts including fixing collar with cement mortar 1:2 but excluding excavation, protection work, backfilling,concrete and masonry work in head walls and parapets clause 1106 of MORD specification for Rural roads and as per irection of Engineer-in charge. |
| 155 | Approach Road |
| 156 | Laying of Interlocking concrete block pavement having thickness of 80mm as per drawing and technical specification clause 1504. (including M-30 Edge block of both side) |
| 157 | Approach Road |
| 158 | Recessed wiring to light point/fan point/exhaust point/call bell point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non-metalic PVC flexible conduit with 5 Amp,one way modular switch ISI marked and ceiling rose ISI marked mounted on Modular G.I. box having front bakelite cover of suitable size , MS box with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire - Polycab/Finolex/ L&T / Anchor / Havells / V Guard/ KEI/ Great White) Modular Type -do- (Gr.A) (1.1.1-1.24.2) |
| 159 | -do- (Gr.B) (1.1.2-1.24.2) |
| 160 | -do- (Gr.C) (1.1.3-1.24.2) |
| 161 | S/F of M.S. Box for 2 Module 18 swg |
| 162 | S/F of M.S. Box for 4 Module 18 swg |
| 163 | S/F of M.S. Box for 6 Module 18 swg |
| 164 | S/F of M.S. Box for 8 Module 18 swg |
| 165 | S/F of M.S. Box for 12 Module 18 swg |
| 166 | S/F of 3 pin 5/6 A.F.T switch and.Socket on existing board (Modular type) (1.25.1+1.25.4) |
| 167 | S/Fof 6 module M.S. Box with Bakelite cover (Modular Type) on surface or in recess including providing and fixing of 2 nos 3 pin 5/6 amp. Socket out let 5/6amp. Piano type modular switch,connection,painting etc. as required (1.24.4 +2 x (1.25.1+1.25.4) |
| 168 | S/F of Power point with 4 modular metal box with modular base & cover in recess including providing and fixing of 6 pin 15/16 amp. piano type Modular switch & Socket, connection, painting etc as required(1.24.2+1.25.5+1.25.5) |
| 169 | S/F of Power point with 4 modular metal box with modular base & cover in recess including providing and fixing of 6 pin 15/16 amp. piano type Modular switch & Socket, connection, painting etc as required(1.24.2+1.25.5+1.25.5) for Inverter Connection |
| 170 | S/F of 2 Modular box with 5A modular Socket outlet of ISI marked on Separate board for Wall fan |
| 171 | S/F of 20 Amp AC Starter(Make Havells/Anchor or Equivalent) |
| 172 | S/F of 15A Socket on 2 module for AC |
| 173 | Wiring for circuit/sub main alongwith earth wire with following sizes of PVC insulated single core multistrand copper conductor with ISI marked conforming to IS-694/1990 in 20 mm dia non metallic heacy duty flexible conduit 1.6 mm in recessed PVC conduit as required (make of wire-Polycab/Finolex/L&T/Anchor/Havels/V-Guard/KEI/Great White).2x1.5 sqmm + 1 x 1.5 sqmm( 1 .8.1) |
| 174 | -do- 2 x 2.5 sqmm + 1 x 1.5 sqmm (1.8.2) |
| 175 | -do- 2x4 sqmm + 1 x 1.5 sqmm (1.8.3) |
| 176 | -do- 4x6 sqmm + 2 x 2.5 sqmm (1.8.10) |
| 177 | -do- 4x10 sqmm + 2 x 4 sqmm (1.8.11) |
| 178 | Inverter wiring (1x1.5smm) Copper wire (1.19.1) |
| 179 | S/F of 5 to 32 Amp rating 240 Volt \\"B\\" series MCB for lighting and other loads in the existing MCB Distribution Board ISI marked complete with connection, testing and commissioning etc. as required (2.6.1) |
| 180 | S/F of MCB 4 Way(4+12) TPN MCB DB Double door (2.5.5) |
| 181 | S/F of MCB 2 Way Single Door (2.3.1(b)) |
| 182 | S/F of 32 Amp rating \\"C\\" Series DP MCB (Make: L&T/Havells/C&S/Equivalent) |
| 183 | S/F of 32A DP Switch with indicator(Make-Havells/Equivalent) |
| 184 | S/F of 63 Amp Four Pole MCB C Series (Make: L&T/Havells/C&S/Equivalent) |
| 185 | S/F of 63A ICDP main switch with MS box of 250mmx300mmx60mm deep ( (2.15A)+(1.24.16 ) |
| 186 | S/F of Call bell/Buzzer(Ding dong type) ISI marked suitable for DC/AC single phase 230 volts complete as required. (1.30) |
| 187 | Supply of 180mmx100mmx60mm deep(1.24.5) for fixing calling bell |
| 188 | S/F of batten holder BK angle holder ISI marked including connection etc. insulated of ceiling rose(1.29- 1.28) |
| 189 | S/F of computer board consisting of 3 nos. of 5 amp modular plug and modular switch and 1no. Of 6 amp Mini MCB, complete with wiring on 12 modular type M.S.box with modular cover. |
| 190 | S/F of Earthingwith GI Pipe 40mm Heavy duty 2.7mtr Electrolyte grade (Cu-ETP) Grade :C 101) coated with Tin and annealed copper plate size 600mmX600mmX3.15mm 10.5kg ,GI funnel covered with wireness duly fabricated and welding with GI Pipe 1 no, Clamp made out of 40X6 mm GI flat- 3 set, fabrication of GI Pipe copper plate and copper flat for a) Perforated hole-18 no. b) threaded hole -12 no., Charcoal 64 kg, common Salt 5 kg, CI hinged top cover 1 no., nut ,bolt and washer -12 sets, Excavation of Earth size 1.35 mm X 0.75mm X 3mm . Construction of Earthing chamber pit size 22\\"x22\\"x18\\"- 3.375 mm |
| 191 | Supply andlaying 8 SWG wire copper loop earthing as required (3.18) |
| 192 | S/F of Fan hook S, Type on ceiling. |
| 193 | S/F of step type modular fan regulator |
| 194 | Supply of instalation, Testing commissioning of 12 Watt. LED bulb(Make:Havells/Polycab or Equivalent) |
| 195 | S/F of 300 Exhaust fan with all accessoriesand connections (Make Usha-Aero Clean Plus DBB/ Polycab-Fresh on DBB/ Cropmton-Trans Air12\\" reversible/ Havells-Ventil Air DS(HS)/ Anchor-Anmol Delus R/ Orient-Power Flow DBB |
| 196 | S/F of 1200mm A.C. Ceiling fan (1Star) with all accessories and connections with out fan regulator (Make:Usha-Striker One/Neo/Crompton- highspeed/Havells-Samrat ES/Anchor- Turbo Speed Star/Orient-Summer Breeze Pro/ Great White-ALDOUS/Pollycab-Vital HS) |
| 197 | S/F of 18-25 wt. LED single strip tube. Light fittingwith all accessories & connection (make Havels/HPL/Crompton/Polycab/PAC) |
| 198 | Supply & Fixing of 60 Watt single L.E.D street light fitting with LED & Electrinic driver including all accessories and connections (Make:Crompton/Phillips/HPL/Polycab/Havells) |
| 199 | S/F OF 2000 VA Invertor with 2 no 180Ah Battery with trolly arrangement(Luminous/Microtek/Excide/V Guard) |
| 200 | S/F of 1.5T 5Star split Inverter type AC Machine, Make-Carrier /Blue Star /Hitachi |
| 201 | S/F of 4 KVA Voltage Stabilizer(110-300V) Upto 1.5 Ton AC, Make-Microtech/V-Guard |
| 202 | S/F of 18 Watt Ceiling Light Recessed Mount or Surface Mount(Round or Square )Type(Make Havells/Crompton/Polycab or Equivalent) |
| 203 | S/F of 24 Watt Ceiling Light Recessed Mount or Surface Mount(Round or Square )Type(Make Havells/Crompton/Polycab or Equivalent) |
| 204 | S/F of 10W LED Bulk Head(Make -Havells/Crompton or Equivalent) |
| 205 | S/F of 400mm A.C. wall fan with all accessories (Make:Usha-Max air ultra/Polycab-Aery HS/Crompton-wmhiflo wave /Havels-Accelero HS/Anchor-Altrix HS/Orient- Wall 43/ Great white- WYNO Pro HS) |
| 206 | Supply and fixing of 100A TPN pannel board 1)100A 4P MCCB with Spreader Ics=100% Ics (MAKE-Legrand/Seimens/L&T/C&S)-01 No 2)100A Changeover (Manual)-1 No.(MAKE-Legrand/Seimens/L&T/C&S)3)63 A 4P 415V AC 10KA C Curve MCB (make-ABB/Siemens/SCHNEIDER/L&T/Legrand)=03 No 4) 40 A C Curve DP MCB (make-ABB/Siemens/SCHNEIDER/L&T/Legrand)=4 Nos)5)SPD(Type1+2,50kA,3P+N)(make-ABB/Siemens/SCHNEIDER/L&T/Legrand)=01 No)6)Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse.- 1 set=06 Nos) 7)(ii) 01 set of digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication with RS 485 COMPACTIVITY FOR bms data.=02 Nos)8)100A/5 CTS=06 Nos) 9)200A cu Bus bar=8.2 Kg |
| 207 | Supply and fixing of 63 A TPN pannel board 1)In commer-1-01 number of 63A 4P 25KA MCCB Icu=100%Ics (make-ABB/Siemens/SCHNEIDER/L&T/Legrand) with spreader, rotary handle, and UV relaease =1 Set)2)63A Manual changeover (make-ABB/Siemens/SCHNEIDER/L&T/Legrand) with Aux contact kit,Operating handle kit and output shorting link =01 Nos)3)63A 4P 415V AC 10KA C Curve MCB (make-ABB/Siemens/SCHNEIDER/L&T/Legrand)=03 Nos)4)40A C Curve DP MCB (make-ABB/Siemens/SCHNEIDER/L&T/Legrand)=02 Nos)4)Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse.- 1 set=02 Nos 5) (ii) 01 set of digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication with RS 485 COMPACTIVITY FOR bms data=02 Nos) 6)100A/5 CTS =06 Nos 7)100A cu Bus bar=4.1 Kg |
| 208 | Supply of 3.5core 50 sqmm PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade Armoured cable ( MAKE-HAVELLS/polycab/RR Kable/Rhino cable/equivalent) |
| 209 | Laying of MV cable above 25sqmm to 120 sqmm in ground (5.1.2) |
| 210 | Laying of MV cable above 25sqmm to 120 sqmm on surface (Horizontally)(5.5.2) |
| 211 | S/F of 40 mm HDPE pipe for laying & protection of cable(Make:Sudhakar or Equivalent) |
| 212 | S/F OF 15W GATE LIGHT FITTING(Make Havells / Equivalent) |
| 213 | Supplying all materials labour T&P and filling F&P with river sand well watered and rammed including conveyance of all materials to worksite,payment of royality,taxes etc. all complete as per the direction of E.I.C. |
| 214 | T Room |
| 215 | S. Tank |
| 216 | Supplying all materials,labour,T&P and fitting & fixing of 4.0kgf/cm2 U-PVC soil waste ventilating pipes and fitting of the following OD conforming to ISI No.13592/ 1992 to walls with nails bobbins and wooden plugs or earth work in excavation in all kinds of soil for laying in trenche including jointing with supply of approved rubber lubricant by non-heat application method/as per manufactures specification including tasting and refilling and trenches as per direction of E.I.C. |
| 217 | (a)110mm dia PVC pipeP-trap to Tee=2x(0.90+1.30)m=4.40mTee to DB=2x1.30m=2.60mDB to PB=24.00m=8.00mPB to SP=12.00m=2.00mP-trap to DB=7x0.60m=4.20mDB to DB=2x2.00m=4.00mTee to Tee=1x4.00m=4.00mDB to PB=1x4.00m=4.00mTee to IC=1x1.50m=1.50mVent Pipe=1x7.00m=7.00mP-trap to Tee=1x(1.30+2.00)m=3.30mTee to Tee=1x(1.30+2.00+1.30)m=4.60mS-trap to Tee=1x0.90=0.90mS-trap to DB=2x0.90m=1.80mDB to DB=1x2.00m=2.00mP-trap to Tee=1x2.00m=2.00mP-trap to DB=2x3.00m=6.00mDB to Tee=(4.00+2.70)=6.70mTee to SP=5x2.00m=10.00mVent pipe=(3x7.00+2.00)m=23.00m |
| 218 | (b)110mm dia PVC \\"P\\"-Trap |
| 219 | (c)110mm dia PVC S/J/D |
| 220 | (d)110mm dia PVC D/J/D |
| 221 | (e)110mm dia PVC Offset |
| 222 | (f)110mm dia PVC cowl |
| 223 | (g)110mm dia PVC Plain Tee |
| 224 | (h)110mm dia PVC Door bend |
| 225 | (i)110mm dia PVC plain Bend |
| 226 | (j)125mm dia CP Grating |
| 227 | Supplying all materials labour T&P and fixing wash down water closet (Anglo Indian water closet)with integral S or P trap to the floor with wooden plug and chromium plated crews including jointing the trap with soil pipe in cm(1:1)etc. all complete as per specification and direction of E.I.C. |
| 228 | (a)E.W.C. with S Trap with sheet cover(make- parryware) |
| 229 | Supplying all materials labour T&P and fixing water closet,squatting pan(Indian type WC. pan/Orissa pattern squatting pan) duly embedded in cc(1:5:10)using 4cm hg. metal all complete as per the direction of E.I.C. |
| 230 | (a)580mm Orissa pan(make- parryware) |
| 231 | Supplying all materials,labour,T&P and fixing bowl pattern urinal including connecting the urinal with waste pipeby means of white lead mixed with chopped hemp etc all complete as per specification and direction of the E.I.C. |
| 232 | Supplying all materials,labour,T&P and fixing glazed earth ware squatting plate size (600x350x100/450x355x100)mm with integral flushing pipe including embedding the plate in 25mm cm(1:8)laid over 150mm cc(1:4:8)using 40mm hg metal etc all complete as per specification and direction of the E.I.C. |
| 233 | Supplying all materials,labour,T&P and fixing kitchen sink with hole for pillar taps with CI/MS brackets painted white including holes in walls and making good the damages etc. all complete as per P.H. specification and direction of E.I.C. |
| 234 | (a)600mmx450mmx200mm Steel sink with 40mm dia CP west,west pipe and brackets.(Mousumi make) |
| 235 | Supplying all materials,labour,T&P and fixing wash basing with hole for pillar taps with CI/MS brackets painted white including holes in walls and making good the damages etc. all complete as per P.H. specification and direction of E.I.C. |
| 236 | (a)550mmx400mm W.H.B. with 32mm dia CP west, west pipe,brackets and connection pipe.(make-parryware) |
| 237 | (b)Pedestrial for W.H.B.(make-parryware) |
| 238 | Supplying all materials,labour T&P and fixing mirror of superior glass mounted on 6mm thick AC sheet or plywood sheet and fixing to wooden plugs with CP screws and washers complete as per PH specification and direction of E.I.C. |
| 239 | (a)600mmx450mm B.E Mirror |
| 240 | Supplying all materials,labour T&P and fixing standard size glass shelf with CP brass brackets and guard rail complete fixed to wooden plugs with CP screws as per PH specification and direction of E.I.C. |
| 241 | (a)(125x450)mm size glass-shelf with CP Guard rail(Jaquar Make) |
| 242 | Supplying all materials,labour T&P and fixing standard size CP towel rail complete with CP Brass brackets fixed to wooden plugs with CP screws as per PH specification and direction of E.I.C. |
| 243 | (a)25mmx600mm long CP towel rail(Jaquar Make) |
| 244 | (b)CP Towel Ring(Jaquar Make) |
| 245 | Supplying all materials,labour T&P and fixing standard size CP soap holder complete with CP Brass brackets fixed to wooden plug with CP screws as per P.H. specification and direction of E.I.C. |
| 246 | (a)CP Soap holder(Jaquar Make) |
| 247 | Supplying all materials labour T&P and cutting holes through brick/stone masonary walls for taking HCI/PVC and fittings including making good the damages etc. all complete as per PH specification and direction of E.I.C. |
| 248 | (a)375mm thick wall |
| 249 | (b)250mm thick wall |
| 250 | (c)Roof cutting |
| 251 | Supplying all materials labour T&P and fixing Digital tiles in floors,threads, landing on 25mm thick bed of cm(1:1)jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing & polishing complete including cost of precast tiles etc. all complete as per specification and directiof E.I.C. |
| 252 | (i)Ground Floor:- |
| 253 | (ii)First Floor:- |
| 254 | Supplying all materials labour T&P and fixing porcelain glazed tiles in dados skirting and risers of steps on 12mm thick CP(1:3)jointed with neat cement slurry mixed with pigments to match the shade of tiles including rubbing & polishing complete including cost of tiles etc. all complete as per spcificaiton and direction of E.I.C. |
| 255 | (i)Ground Floor:- |
| 256 | (ii)First Floor:- |
| 257 | Supplying all materials,labour,T&P and providing marble slab in urinal partition wall including cutting grooves in walls and making good the damages including watering curing etc all complete as per specification and direction of the E.I.C. |
| 258 | Providing fitting fixing Al door with anodized Al door section of 9202 as vertical member,9201 as top,9200 as bottom and middle member with frame section as 9221with tapered clip no 4660 & frame to be completed by means of jointing angle no 1855 including cost of labour T&P hire charges of drilling machine labour charges etc complete with cost of laminated board.and as per direction of the E.I.C. |
| 259 | S.D. PORTION |
| 260 | Supplying all materials labour T&P and constructing inspection chamber of the following sizes with cc(1:3:6)using 40mm size hg metal on bed,1stclass KB brick work in cm(1:6)moulding & shaping the channel inside and benching with cc(1: 1.5:3)using 12mm size hg chips,12mm thick CP(1:3)with punning to inside, cement flush pointin(1:3)to outside,RCC cover slab in cc(1:1.5:3)using 12mm size hg chips with RCC man hole cover,e.w in excavation in all kinds of soil and refilling the cavity around the chamber including watering,curing,conveyance of all materials to site,payment of royality,taxes etc. all complete as per approved specification and direction of E.I.C. |
| 261 | (a)Inside size 760mmx760mmx460mm |
| 262 | Supplying all materials,labour,T&P and constructing Manhole Chamber of the following sizes with cc(1:3:6)using 40mm size HG metal on bed,1st class KB brick work in cm(1:6)moulding and shaping the channel inside and benching with cc(1:1.5:3)using 12mm size HG chips,12mm thick CP(1:3)with punning to inside, cement flush pointing(1:3)to outside,RCC cover slab in cc(1:1.5:3)using 12mm size HG chips with RCC manhole cover,earthwork excavation in all kinds of soil and refilling the cavity around the camber including watering,curing,conveyance of all materials to worksite,payment of royalty,taxes etc. all complete as per approved specification and direction of E.I.C. |
| 263 | (a)Inside size 910mmx910mmx910mm |
| 264 | Supplying all labour T&P and constructing soakway pit of the following sizes with dry brick walling from bottom upto invert of inlet pipe and 1st class KB brick work in cm(1:6)for the remaining height at top,12mm thick CP(1:4)inside and outside over masonary brick work gravel packing in the rear of well steining RCC cover slab in cc(1:1.5:3)using 12mm size hg chips fitted handles including e.w. in openwell excavation in all kinds of soil and refilling the cavity around the pit & painting the iron work,watering,curing,conveyance of all meterails to work site, payment of royality,taxes etc. all complete as per approved drawing specification and direction of E.I.C. |
| 265 | (a)1.20m dia x 2.00m deep |
| 266 | Supplying all materials labour T&P and laying PVC pipe sewer line,Grade-A of the following internal dia in trenches (to level or slope)and jointing with gasket & stiff mixture or cm(1:1),cc(1:3:6)with 40mm size h.g. metal on bed of the trench and hunching or allround concrete encasing with cc(1:4:8)using 40mm size hg. metal including curing,conveyance to workside,payment of royality,taxes etc and testing all complete as per approved drawing,specification and direction of E.I.C. |
| 267 | (a)160mm dia PVC pipe with allround encasing |
| 268 | 50 USER SEPTIC TANK:- |
| 269 | Earth work in all kinds of soil in excavation of foundation trenches within 50m initial lead including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth as per direction of E.I.C. |
| 270 | (a) Initial lift upto 1.50m S.Tank |
| 271 | (b) From 1.50m to 3.00m depth S.T. |
| 272 | Supplying all materials labour T&P and providing cc(1:3:6)using 4cm h.g metal including watering,curing,conveyance of all materials to work site,payment of royality,taxes etc. all complete as per specification and direction of E.I.C. |
| 273 | Supplying all materials labour T&P and providing cc(1:1.5:3)using 12mm hg chips including watering,curing,conveyance of all materials to worksite,payment of royality,taxes etc. all complete as per specification and direction of E.I.C. |
| 274 | Supplying all materials labour T&P and providing brick work with flyash Bricks in cm(1:4)F&P having crushing strength not less than 75kg/cm2 with dimensional tolerance +/-8% including watering,curing conveyance all materials to worksite payment of royality taxes etc. all complete as per specification direction of E.I.C. |
| 275 | Supplying all materials,labour T&P and providing 12mm thicks CP(1:3)with punning on brick/stone work including watering,curing conveyance of all materials to worksite,payment of royality,taxes etc. all complete as per specification and direction of E.I.C. |
| 276 | Supplying all materials labour T&P and providing rigid & smooth centering & shuttering for RCC works including false work and dismantling them after casting including conveyance of all materials to worksite,payment of royality,taxes etc. all complete as per specification and direction of E.I.C. |
| 277 | Supplying all materials labour T&P and providing MS reinforcement for RCC works including cutting,bending,binding and tying the grills & placing in position including cost of binding wire 18 to 20 gauge conveyance of all materials to work site,payment of royality,taxes etc. all complete as per specification and direction of E.I.C. |
| 278 | Supplying all materials labour T&P and providing RCC(1:1.5:3)using 12mm hg chips including hoisting,laying,watering,curing,conveyance of all materials to work site,payment of royality,taxes etc. all complete as per specification and direction of E.I.C. |
| 279 | Supplying all materials labour T&P and fixing MS step iron in 12mm dia MS steel bar and fixing into walls of septic tank duly embedded in cc(1:3:6) all complete as per PH. specification and direction E.I.C. |
| 280 | Supplying all materials labour T&P and fixing of RCC baffle wall precast with cc(1:1.5:3)using 12mm b.h.g. chips and fitted to septic tank as per P.H. specification and direction E.I.C. |
| 281 | Supplying all materials,labour,T&P and providing fitting & fixing PVC Tee in wall including fitting the necessary with cc(1:1.5:3)with 12mm size hg chips all complete including watering,curing,conveyance of all materials to worksite, payment of royality,taxes etc. all complete as per specification and direction of E.I.C. |
| 282 | (a) 160mmx160mm x160mm PVC Tee |
| 283 | Supplying all materials labour T&P and Providing cement flush pointing(1:3)to brick masonary including watering,curing,conveyance of all materials to work site etc. all complete as per specification and direction of E.I.C. |
| 284 | Filling in F&P with excavated materials including watering and ramming as per direction of E.I.C. |
| 285 | W/S SUPPLY PORTION:- |
| 286 | Supplying all materials,labour,T&P and construction of masonry staging with providing 1stclass KB brickwork in cm(1:6)of 0.46m height in staging,12mm CP in cm(1:6),RCC Beam of 0.25mx0.30mx2.60m in cc(1:1.5:3)using 12mm size HG chips including centering,shuttering,bending&binding of rod etc watering,curring, conveyance of all materials to worksite,payment of royalty,taxes etc all complete as per P.H specification and direction of the E.I.C. |
| 287 | (a)Stagging for 2000Ltr. Storage Tank |
| 288 | Supplying all materials,labour,T&P and Fitting and Fixing of Rotational moulded polythene cylindrical vertical water storage tank conforming to 12701/1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jamnuts including hoisting upto a height of 5mtr above G.L and placing the tank in required position including conveyance of all materials to work site,payment of royalty,taxes etc all complete as per P.H specification and direction of the E.I.C. |
| 289 | (a)2000Ltr. Capacity Water Storage Tank |
| 290 | Supplying all materials,labour,T&P and fitting & fixing 10ltr. capacity low level flushing cystern with a pair of ms clamps complete with fittings such as syphonic arrangements 15mm nominal size PVC ball valve with polythene float,PVC handle,union and couplings for connection with inlet,outlet and overflow pipes, 32mm dia CP flush bend,15mm dia,PVC inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cystern and closet and connecting inlet pipe with supply main etc. all connecting inlet pipe with supply main etc. all complete as per specification and direction of E.I.C. |
| 291 | (a)10Lit. PVC Cistern(Parryware make) |
| 292 | Supplying all materials,labour,T&P providing and fixing to wall or ceiling and floor PVC pipe conforming to ASTM-D-1785/89 (sch-80) and pipe fitting of the following nominal bore with clamps including making good the wall,ceiling and floor testing all complete as per specification and direction of E.I.C. |
| 293 | (a)25mm dia PVC pipe(External |
| 294 | (b)20mm dia PVC pipe(Internal) |
| 295 | ©40mm dia PVC pipe |
| 296 | Supplying all materials,labour,T&P cutting holes through brick/stone masonry works including making good the damages in cm(1:4)for taking GI/PVC pipe & fitting etc. all complete as per PH specification and direction of E.I.C. |
| 297 | (a)250mm thick wall (Ground Floor) |
| 298 | (b)250mm thick wall (1st. Floor) |
| 299 | Supplying all materials,labour,T&P and cutting grooves in pucca floors and walls for taking GI/PVC pipes and making good the damages as per direction of E.I.C. |
| 300 | (a)Ground Floor |
| 301 | (b1st. Floor |
| 302 | Supplying all materials,labour,T&P and fitting & brass/CP fittings of the following nominal bore with supply of all jointing materials etc.complete as per P.H. specification and direction of E.I.C. |
| 303 | (a)15mm dia CP Bib cock(make-Jaquar) |
| 304 | (b)15mm dia CP Two way Bib cock(make-Jaquar) |
| 305 | (c)15mm dia CP(L.B)Bibcock(make-Jaquar) |
| 306 | (d)15mm dia CP Pillar cock (make-Jaquar) |
| 307 | (e)15mm dia CP Angle Stop cock(make-Jaquar) |
| 308 | (f)15mm dia CP Concealed stop cock(make-Jaquar) |
| 309 | (g)15mm dia CP Revolving Shower with shower Arm(make-parry ware) |
| 310 | (h)15mm dia Health Faucet & 1.0m long Flexible pipe(make-Jaquar) |
| 311 | (i)25mm dia U-PVC F.W.V. |
| 312 | (j)15mm dia CP Extension Piece |
| 313 | (k)15mm dia CP Flange |
| 314 | Sinking of 200mmx150mm dia Tube well by Odex Rig. |
| 315 | Labour for drilling of perfactly vertical bore holes as specified dia.For a specified depth below G.L through consolidated & uncosolidated rock with down the hole hammer drilling rigs or combination drilling rigs(1200cfm/300psi)as required to suit the site conditions as per the direction of E.I.C. including use of own rigs with its accessories,tools & plants and consumable etc. for lowering 200mm dia PVC/GI pipes for house fitted with socket and with or without well screen as per the necessity for the soft,medium,hard & boulder formation(PCV/GI)casing pipes if required to prevent collapse of over burden is to be provided by the contractor including lowering and withdrawing after complete of tube well.(Tube well-1No) |
| 316 | 0.00 mtr to 29.40 mtr |
| 317 | Drilling of 150mm dia bore |
| 318 | 29.40 mtr to 200.00 mtr |
| 319 | Labour for drilling a perfectly vertical bore hole of 200mm dia.for a specified depth below ground boulder zone through consolidated & uncosolidated rock with down the hole hammer drilling rigs or combination drilling rigs as required to suit the site conditions as per the direction of E.I.C. including use of own rigs with its accessories,tools & plants and consumable etc. for soft,medium,hard rock formation as per direction of E.I.C. |
| 320 | Lowering of 200mm dia MS pipes:00.00 mtr to 200.00mtr |
| 321 | Cost of 200m dia MS pipes:-00.00mtr to 200.00mtr |
| 322 | Cleaning and developing the Tube well with their own compressor contineously worked till clean and adiquate discharge is obtained from the tube well including supply of and use of all necessary equipments and labour as per the direction of E.I.C. |
| 323 | Supplying all materials,labour,T&P and fitting and fixing of ISI mark 1HP single phase vertical water cool submersible pump set with discharge 1800/2200Lit /Hour & a head-55/70mtr.of reputed make(CRI/KSB/Texmoor equivelent Including cost conveyance and taxes etc. all completes as per P.H. Specification and direction of E.I.C. |
| 324 | Supplying all materials,labour,T&P and fitting & fixing of 1.0HP single phase vertical submersible pump set with commissioning and testing etc. all completes as per P.H. Specification and direction of E.I.C. |
| 325 | Supplying all materials,labour,T&P and fitting & fixing of ISI mark DOL starter of reputed make like BCH or equivalent for 1HP single phase vertical submersible pump set including all cost conveyance & taxes etc. all completes as per P.H. Specification and direction of E.I.C. |
| 326 | Supplying all materials labour T&P and fitting & fixing of 2.5mm2 3core copper flat suitable cable having ISI mark of reputed company like BCH/Finolex or equivalent & connecting the pump starter including cost conveyance & taxes etc. all completes as per P.H. Specification and direction of E.I.C. |
| 327 | Supplying all materials labour T& P and fitting&fixing plastic rope with MS well cover,MS Clamp,stainless steel short piece,Bend & socket,union including all cost conveyance & taxes etc. all completes as per PH. Specification direction of E.I.C. |
| 328 | Supplying all materials labour T&P and fitting&fixing of HDPE pipes & pipe fittings with making connection to pump set including all cost conveyance & taxes etc.all completes as per P.H. Specification direction of E.I.C. |
| 329 | Supply of all materials,labour,T&P and fitting & fixing of 5KW automatic voltage stabilizer having range from 50Volt to 220Volt suitable to run 1.00HP Submersible pump set including electrical connection from the existing mains & with the control panels of the pump set etc.all complete as per specification and direction of E.I.C. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |