| 1 | Description items |
| 2 | Supply and Instalation of Painted/ Powder coated galvanized steel Flush Fire doors INCLUDING The internal construction of the door should be appropriate for all hardware fixtures (SS Ball BearingHinges-4\\"x3\\"X3mmGeze,Door Closer, Dead LockWith 70mm EPC,Handle-300X19mm, Vision Panel,Flush Bolt etc.) as per SITE requirement and approved make of 2 hrs. Fire rating and tested in accordance with IS 3614 Part 2 & BS 476 Part 22 as per prototype tested and certified at CBRI Roorkee or equivalent laboratory. Door frames to be double rebate profile of 143 x 57mm manufactured from 1.6mm galvanized steel sheet, profile to have bending radius of 1.4 mm supplied in assembled form ready to install at site. Door Shutter in 46mm +2 mm thick manufactured from 1.2mm galvanized steel sheets, lock seam jointed at stile edges to form a double skin fully flush shell. Infilled honeycomb insulation material to be provided for structural rigidity & additional reinforcements & sound Insulation, as required, vision panel grooves wherever applicable shall be provided as per recommendations with beading and screw. - Double Leaf Size1800 x 2100 mm |
| 3 | Supply, installation, testing and commissioning of UPS with isolation transformer & battery for backup, having three phases input three phase output. Online double conversion VFI-SS-111 technology, with sinusoidal wave form, architecture (standalone of distributed parallel up to 8 units), having input characteristics i.e. input voltage (380v, 400v, 415v, 3Ph+N+PE), input frequency (45 -65 Hz), input voltage range (Ph - Ph) : (half load 208v -467v/ full load 312v - 467v), total harmonic distortion of input current < 3% (at full linear load), compatibility with diesel generators configurable for synchronization between the input and output frequencies even for high frequency variations, input power factor > 0.99, having output characteristics i.e. output voltage (380v, 400v, 415v, 3Ph+N (adjustable from front panel), efficiency up to 96%, efficiency in ECO mode up to 98.5%, output frequency (nominal) 50 /60 Hz 0.01% free run (adjustable from front panel), crest factor 3 : 1, total harmonic distortion of output voltage < 2 % (at full linear load), output power factor 0.9, output voltage tolerance ± 1%, built in automatic and maintenance bypass, inbuilt isolation transformer, battery type (VRLA - AGM maintenance free). Communication & management i.e. 30 KVA (3 phase input & 3 phase output) For 30 minute backup, min. 24000 VAH |
| 4 | Supply, installation, testing and commissioning of EPABX system consist, no. of extension, no of junction, no. of expandable eport, operating console, current on max. load with ISDN compatible of approved make and labor as required as per specifications. |
| 5 | EPABX system consists of 64 nos. extensions, 16 nos of junction & upto 128 nos. of expandable eport, with one operating console, 3 Amp max. current |
| 6 | Supply, installation, testing and commissioning of telephone instrument as approved by architect (Siemens/ Panasonic/ Tata/ BPL) Please Enable Macros to View BoQ information |