| Sl. No. | Item Description |
| 1 | \\" BOQ \\" BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority : CE BATHINDA ZONE Name of Work: PROVISION OF OTM ACCOMMODATION FOR FIELD HOSPITAL AT BIKANER MILITARY STATION (JOB NO SW/229) Contract No: CE BTZ/BKN/TOKEN-77 OF 2025-26 Bidder Name : GENERAL SUMMARY (SCHEDULE OF WORKS) (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # NUMBER # Sl.No. Description of Parts/ Item Item Code / Make No. orQty. Unit Pre Priced Rate (in. Rs.) as Defined by MES Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder Rs. Ps. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT in Figure TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words Represent (%) Percentage having Above/ Below ( + or - denomination) the Lump sum pre price inserted by MES |
| 2 | NOTE:- (Applicable for all parts/items/):- The bidders/contractors are advised to read tender document, all drawings & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates. |
| 3 | Lump sum price worked out by the tenderer for BUILDING WORKS as listed in Schedule ‘A’ Part-I (B)(Ref pre-priced schedule attached separately) |
| 4 | Lump sum price worked out by the tenderer for INTERNAL ELECTRIFICATION WORKS as listed in Schedule ‘A’ Part-II(Ref pre-priced schedule attached separately) |
| 5 | Lump sum price worked out by the tenderer for INTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’ Part-III(Ref pre-priced schedule attached separately) |
| 6 | Lump sum price worked out by the tenderer for ROAD, PATH AND CULVERT WORKS as listed in Schedule ‘A’ Part-IV(Ref pre-priced schedule attached separately) |
| 7 | Lump sum price worked out by the tenderer for AREA DRAINAGE WORKS as listed in Schedule ‘A’ Part-V(Ref pre-priced schedule attached separately) |
| 8 | Lump sum price worked out by the tenderer for SEWAGE DISPOSAL WORKS as listed in Schedule ‘A’ Part-VI(Ref pre-priced schedule attached separately) |
| 9 | Lump sum price worked out by the tenderer for SECURITY FENCING AND GATE WORKS as listed in Schedule ‘A’ Part-VII(Ref pre-priced schedule attached separately) |
| 10 | Lump sum price worked out by the tenderer for EXTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’ Part-VIII(Ref pre-priced schedule attached separately) |
| 11 | Lump sum price worked out by the tenderer for EXTERNAL ELECTRIFICATION, STANDBY DG SET AND LIGHTENING PROTECTION WORKS as listed in Schedule ‘A’ Part-IX(Ref pre-priced schedule attached separately) |
| 12 | Lump sum price worked out by the tenderer for AIR CONDITIONING, SUMMER APPLIANCES AND HOT WATER SUPPLY WORKS as listed in Schedule ‘A’ Part-X(Ref pre-priced schedule attached separately) |
| 13 | Lump sum price worked out by the tenderer for DEMOLITION/DISMANTLING WORKS as listed in Schedule ‘A’ Part-XI(Ref pre-priced schedule attached separately) |
| 14 | Lump sum price worked out by the tenderer for EXCAVATION, EARTHWORK AND SITE DEVELOPMENT WORKS as listed in Schedule ‘A’ Part-XII(Ref pre-priced schedule attached separately) |
| 15 | Schedule 'A' Part-XIII(ARBORICULTURE) |
| 16 | M & L for grassing with selection No. 1 grass in rows 5 cm apart in both directions including watering and maintenance of the lawn for 60 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth complete all as specified and as directed. Note: The earth shall be paid for separately. |
| 17 | M & L for preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete all as specified and as directed. Note: Cost of sludge, manure or extra earth to be paid for separately. |
| 18 | M & L for digging holes of 1.2 metre dia and 1.2 metre depth in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts including anti-termite treatment by digging pits 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration including supplying, stacking and planting of Canerydate Palm plant of height 120-130 cm in big polybag of size 25 cm complete all as specified and as directed. Note: The contractor’s quoted rate shall be inclusive of excavation, earthworks, manure, sludge, anti-termite treatment, supplying of good earth from outside MD land if not found suitable from the excavated earth, etc. |
| 19 | M & L for digging holes of 1.2 metre dia and 1.2 metre depth in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts including anti-termite treatment by digging pits 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration including supplying, stacking and planting of plumeria plant of height 120-130 cm in big polybag of size 25 cm complete all as specified and as directed. Note: The contractor’s quoted rate shall be inclusive of excavation, earthworks, manure, sludge, anti-termite treatment, supplying of good earth from outside MD land if not found suitable from the excavated earth, etc. |
| 20 | M & L for digging holes of 0.3 metre dia and 0.45 metre depth in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts including anti-termite treatment by digging pits 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration including supplying, stacking and planting of Bouganvillea/Tecoma tree of height 1 to 1.5 feet in polybag of suitable size complete all as specified and as directed. Note: The contractor’s quoted rate shall be inclusive of excavation, earthworks, manure, sludge, anti-termite treatment, supplying of good earth from outside MD land if not found suitable from the excavated earth, etc. |
| 21 | M & L for digging holes of 0.3 metre dia and 0.45 metre depth in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts including anti-termite treatment by digging pits 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration including supplying, stacking and planting of Tecoma tree of height 1 to 1.5 feet in polybag of suitable size complete all as specified and as directed. Note: The contractor’s quoted rate shall be inclusive of excavation, earthworks, manure, sludge, anti-termite treatment, supplying of good earth from outside MD land if not found suitable from the excavated earth, etc. |
| 22 | M & L for digging holes of 0.3 metre dia and 0.45 metre depth in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts including anti-termite treatment by digging pits 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration including supplying, stacking and planting of chandani tree of height 1 to 1.5 feet in polybag of suitable size complete all as specified and as directed. Note: The contractor’s quoted rate shall be inclusive of excavation, earthworks, manure, sludge, anti-termite treatment, supplying of good earth from outside MD land if not found suitable from the excavated earth, etc. |
| 23 | M & L for digging holes of 1.2 metre dia and 1.2 metre depth in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts including anti-termite treatment by digging pits 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration including supplying, stacking and planting of Kaner of height 120-130 cm in big polybag of size 25 cm complete all as specified and as directed. Note: The contractor’s quoted rate shall be inclusive of excavation, earthworks, manure, sludge, anti-termite treatment, supplying of good earth from outside MD land if not found suitable from the excavated earth, etc. |
| 24 | M & L for digging holes of 1.2 metre dia and 1.2 metre depth in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts including anti-termite treatment by digging pits 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration including supplying, stacking and planting of Neem of height 120-130 cm in big polybag of size 25 cm complete all as specified and as directed. Note: The contractor’s quoted rate shall be inclusive of excavation, earthworks, manure, sludge, anti-termite treatment, supplying of good earth from outside MD land if not found suitable from the excavated earth, etc. |
| 25 | M & L for digging holes of 1.2 metre dia and 1.2 metre depth in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts including anti-termite treatment by digging pits 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration including supplying, stacking and planting of Karanj of height 120-130 cm in big polybag of size 25 cm complete all as specified and as directed. Note: The contractor’s quoted rate shall be inclusive of excavation, earthworks, manure, sludge, anti-termite treatment, supplying of good earth from outside MD land if not found suitable from the excavated earth, etc. |
| 26 | M & L for digging holes of 1.2 metre dia and 1.2 metre depth in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts including anti-termite treatment by digging pits 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration including supplying, stacking and planting of Gulmohar tree of height 120-130 cm in big polybag of size 25 cm complete all as specified and as directed. Note: The contractor’s quoted rate shall be inclusive of excavation, earthworks, manure, sludge, anti-termite treatment, supplying of good earth from outside MD land if not found suitable from the excavated earth, etc. |
| 27 | M & L for digging holes of 1.2 metre dia and 1.2 metre depth in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts including anti-termite treatment by digging pits 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration including supplying, stacking and planting of Ashoka tree of height 120-130 cm in big polybag of size 25 cm complete all as specified and as directed. Note: The contractor’s quoted rate shall be inclusive of excavation, earthworks, manure, sludge, anti-termite treatment, supplying of good earth from outside MD land if not found suitable from the excavated earth, etc. |
| 28 | Complete maintenance after physical completion of plants/Hedge/grass by weeding hosing, saucer making once in every week for plants/Hedge once in every 10 days for carpet grass/country grass/doob grass, burmuda grass, prunning dried branches once in every week, depositing the material at place as directed by Engr-In-Charge and planting the new plants in place of dead plants of same species and height tuning with dods wherever required by replacing the dead patches of grass with the same grass as required without extra cost to the deptt and all as directed by Engr-In-Charge.Note:(i) Manure and pesticide required for maintenance of plant under this items shall be arranged by the contractor at his own cost and rate of the same shall be deemed to be included in the unit rate quoted against this items(ii) Work against this item will be commenced only after completion of plantation of trees, plantation of grass and plantation of hedge & shrubbery. |
| 29 | Schedule 'A' Part-XIV(FURNITURE WORKS) |
| 30 | Supply only Almirah Meduim Steel all as specified in drawing No FD-1032 |
| 31 | Supply only Book Case Steel all as specified in drawing No FD-1028 |
| 32 | Supply only Chair Revolving all as specified in drawing No FD-75M |
| 33 | Supply only Chair CBA Steel all as specified in drawing No HFD/2045 |
| 34 | Supply only Display Board (6'x4') TPBrand : GoshuMaterial : Non magnetic |
| 35 | Supply only Drugget (3x2 mtr) TPMake: Zara Carpets or its equivalent. |
| 36 | Supply only Hat Stand all as specified in drawing No FD-233 |
| 37 | Supply only Side Rack with Trays all as specified in drawing No FD-1023 |
| 38 | Supply only Sofa Set 2 Seats all as specified in drawing No FD-373 |
| 39 | Supply only Stool Steel Type 1 all as specified in drawing No HFD-2007 |
| 40 | Supply only Stool Steel (with back rest) Type 2 all as specified in drawing No HFD-2007 |
| 41 | Supply only Table Office Offrs all as specified in drawing No FD-1003 |
| 42 | Supply only Table Centre all as specified in drawing No FD-274 |
| 43 | Supply only Chair CB Steel Padded with Arms all as specified in drawing No FD-75(M)/386 |
| 44 | Supply only Bed Hard with MNF Set all as specified in drawing No FD/E6/MAP/07 |
| 45 | Supply only Mattress with pillow TPMake: Duroflex |
| 46 | Supply only Table Bedside all as specified in drawing No FD/MAP/15(R) |
| 47 | Supply only Almirah Large Steel all as specified in drawing No FD-1031 |
| 48 | Supply only Table Office Clerk all as specified in drawing No FD-1004 |
| 49 | Supply only Chair CB Steel all as specified in drawing No HFD/2044 |
| 50 | Supply only Side Rack all as specified in drawing No HFD-2042 |
| 51 | Supply only Chair Easy with Cushion all as specified in drawing No FD-358 |
| 52 | Supply only Sofa Set 5 Seater all as specified in drawing No FD-373 |
| 53 | Supply only Almirah Pigeon holes with Locks TPBrand : Sri LakshmiMateraial : Mildsteel |
| 54 | Supply only Bench Workshop all as specified in drawing No FD-1024 |
| 55 | Supply only Chair Wooden Bottom all as specified in drawing No FD-285 |
| 56 | Supply only Form with Back all as specified in drawing No FD-78(M) |
| 57 | Supply only Rack Arms all as specified in drawing No BTD-096 |
| 58 | Supply only Receptacle all as specified in drawing No FD/E6/MAP/13 |
| 59 | Supply only Table 3x2 w/o drawer all as specified in drawing No DFD-1007 |
| 60 | Supply only Trestle store room all as specified in drawing No FD-1043 |
| 61 | Supply only Rack Rifles all as specified in drawing No BTD-627 |
| 62 | Supply only Bath Mat all as specified in drawing No FD/E6/MAP/07 |
| 63 | Supply only Chair Easy all as specified in drawing No HFD/2034 (1/1) |
| 64 | Supply only Chair Writing all as specified in drawing No FD-280 |
| 65 | Supply only Table Peg all as specified in drawing No FD-277 |
| 66 | Supply only Table Writing all as specified in drawing No FD-275 |
| 67 | Supply only Table Dressing Gents all as specified in drawing No FD-230 |
| 68 | Supply only Charpoy IP all as specified in drawing No FD/MAP-II/01 |
| 69 | Supply only Table 3x2 with drawer all as specified in drawing No FD-283 |
| 70 | Supply only Teapoy all as specified in drawing No FD-278 |
| 71 | Supply only Chair Dinning all as specified in drawing No FD-279 |
| 72 | Supply only Table Dining 6 Person all as specified in drawing No FD-273 |
| 73 | Supply only Table Dining Ors all as specified in drawing No FD-165(M) |
| 74 | Supply only Notice Board (1800x1200mm) all as specified in drawing No HFD/2037 |
| 75 | Supply only Sofa set 3 Seater all as specified in drawing No FD-373 |
| 76 | Supply only Hot Case all as specified in drawing No HFD/2067 (1/1) |
| 77 | Supply only Table Pantry all as specified in drawing No FD-1020 |
| 78 | Supply only Table Cook House all as specified in drawing No FD-1019 |
| 79 | Supply only Safe meat and Milk all as specified in drawing No FD-407 |
| 80 | Supply only Lockers all as specified in drawing No HFD-2033 |
| 81 | Supply only Table 2x2 Steelall as specified in drawing No FD-142(M) |
| 82 | Supply only Stool wdn TPBrand : SH Furnitue or equivalentMaterial : Seesham Wood |
| 83 | Supply only Form without back all as specified in drawing No FD-97(M) |
| 84 | Supply only Chair Barber with adj neck rest TPMake: JSK Beauty Salon, Model : JBC-01 or equivalent |
| 85 | Supply only Mirror Large size (4'x3')TP |
| 86 | Supply only Rack Steel all as specified in drawing No HFD/2039 (1/1) |
| 87 | Supply only Ladder all as specified in drawing No FD-1025 |
| 88 | Supply only Chair CBA Spl with hand Rest all as specified in drawing No FD-120(M) |
| 89 | Supply only Stool Revolving with Back Rest/ Heavy Base on Castors all as specified in drawing No FD-1026,354,126(M) |
| 90 | Supply only Table 3x2 SS Top Castors all as specified in drawing No HFD/2014 |
| 91 | Supply only Bedstead Iron Hospital all as specified in drawing No HFD-2001 |
| 92 | Supply only Table Bedside Steel all as specified in drawing No HFD/2005(1/2) |
| 93 | Supply only Screen Movable all as specified in drawing No HFD/2015 |
| 94 | Supply only Side Rack with trays all as specified in drawing No FD-1023 |
| 95 | Supply only Workshop Bench all as specified in drawing No FD-1024 |
| 96 | Supply only Bar Stool 3\\" high cushioned TP |
| 97 | Supply only Book case open small all as specified in drawing No FD-237 |
| 98 | Supply only Chair dining long back all as specified in drawing No FD-357 |
| 99 | Supply only Chair Verandah all as specified in drawing No FD-256 |
| 100 | Supply only Chair writing steel all as specified in drawing No FD-360 |
| 101 | Supply only Magzine Rack Medium all as specified in drawing No FD-365 |
| 102 | Supply only Plate Rack TP |
| 103 | Supply only Side Board all as specified in drawing No FD-1112 |
| 104 | Supply only Stool Dressing all as specified in drawing No FD/E6/MAP/14 |
| 105 | Supply only Table dining 8 persn all as specified in drawing No FD-273 |
| 106 | Supply only Table dressing Ladies all as specified in drawing No FD/E6/MAP-II/07 |
| 107 | Supply only Table cook with Aluminium Top all as specified in drawing No FD-1019 |
| 108 | Supply only Table Office steel all as specified in drawing No FD-84(M) |
| 109 | Supply only Teapoy Verandah all as specified in drawing No FD/E6/MAP/17 |
| 110 | Supply only Table card with 4 chairs all as specified in drawing No FD-353/288 |
| 111 | Supply only Durrie 15'x12' TP |
| 112 | Supply only Table 3x3 all as specified in drawing No FD-288 |
| 113 | Supply only Table Service all as specified in drawing No FD-411 |
| 114 | Supply only Couch Examination with foot steps all as specified in drawing No HFD/2019 |
| 115 | Supply only Stool adjustable steel all as specified in drawing No FD-354 |
| 116 | Supply only Table SS Top all as specified in drawing No HFD/2014 |
| 117 | Supply only Desk Stand Lecture all as specified in drawing No FD-1022 |
| 118 | Supply only Pointer Medium, long, shortall as specified in drawing No FD-406 |
| 119 | Supply only Peg set of 3 all as specified in drawing No FD-80(M) |
| 120 | Supply only Table for Class Room TPBrand : DG DEXAGLOBLE or equivalentMaterial : Metal |
| 121 | Supply only Chair umpire TPSold by : sportsfield solution Pvt Ltd or equivalentMaterial : Mild Steel |
| 122 | Supply only Shoe rack TPBrand : Indian Décor or equivalentMaterial : metal |
| 123 | Supply only 3 seater chair TPBrand : PVR Engineering or equivalentMaterial : Stainelss Steel |
| 124 | Supply only Rubber mat TPBrand : Ameengi or equivalentMaterial : Rubber |
| 125 | Supply only Working table size 60x24x34 |
| 126 | Supply only Working table size 44x24x34 |
| 127 | Suplly only plate rack (100 capacity) |
| 128 | Suplly only Stainelss Steel Veg Rack |
| 129 | Suplly only Stainless steel 4 selves rack |
| 130 | Suplly only Stainless steel dining table 6 seater |
| 131 | Suplly only Stainless steel dining table 8 seater |
| 132 | Suplly only Modern Dining Chair |
| 133 | Suplly only Staineless Steel Double sink |
| 134 | Suplly only Utensil rack (bartan rack) |
| 135 | Schedule 'A' Part-XIV(MISCELLANEOUS PARTS) |
| 136 | Taking down and disconnecting old unserviceable submain wiring any type complete all as specified and directed by engr-in-Charge. |
| 137 | Taking down carefully switch,socket,ceiling rose ,lamp removing u/s item from site complete all as specified and as directed. |
| 138 | Dismantling tubrlight fitting any type and wattage or CFL fitting any type or flame proof alongwith luminaire and removing u/s item from site complete all as specified and as directed. |
| 139 | Taking down old perished DB any type by necessary cutting ,chasis including disconnection of incoming and outgoing cable and removing u/s item from site complete all as specified and as directed. |
| 140 | Taking down old MCCB/isolator/MCBs any type by necessary cutting ,chasis including disconnection of incoming and outgoing cable and removing u/s item from site complete all as specified and as directed. |
| 141 | Taking down old unserviceable earthing any type and removing to MES store yard or taken on schedule of credit complete all as specified and as directed. |
| 142 | Dismantling & taking out air termination rod 300/450mm long & 12/16 mm dia alongwith and removing u/s item from site complete all as specified and as directed. |
| 143 | Dismantling & taking out old aluminium strip any type and any size from site complete all as specified and as directed. |
| 144 | Taking down old unserviceable Fan Regulator from site complete all as specified and as directed. |
| 145 | Supplying, installing, testing and commissioning refrigerator, electric driven (single phase), frost-free, single door, auto defrost to stop Ice built-up, automatic adjustment of speed in response to cooling demand, capacity upto 195 litres (nearest available). BEE 5 star rated complete with all accessories such as mounted trolley, complete all as specified and as directed. |
| 146 | Supplying, installing, testing and commissioning refrigerator, electric driven (single phase), frost-free, double door, auto defrost to stop Ice built-up, automatic adjustment of speed in response to cooling demand, capacity upto 310 litres (nearest available). BEE 5 star rated complete with all accessories such as mounted trolley, complete all as specified and as directed. |
| 147 | Supply and Installation of Desert cooler electric driven single phase 230 volts steel body having nominal air flow capacity of 4000 Cu M per hours with necessary inlet connection with HDPE/Flexible pipe both ends CP brass union for GI pipe complete including electric connection complete all as specified and as directed. |
| 148 | Supply and fix Cock, stop, brass chromium plated, screwed down for size 15 mm (1/2”) dia pipe complete all as specified and as directed. |
| 149 | Supplying, installing, testing and commissioning automatic, servo controlled, indoor type, voltage stabilizer of capacity 1 kVA, single phase, IP55 protection, copper wound, naturally air cooled type, insulation class H, designed for input voltage of 160 V to 270 V and output voltage of 230 V ± 1%, voltage correction rate of 15 V per second, metallic body with lifting hook duly power coated, LCD display for Input and Output Voltage, frequency, current, Time Delay and Mains ON with under and over voltage protection, short circuit protection, surge protection all as per IS 8448: 1989 complete all as specified and as directed. |
| 150 | Supply, installing, commissioning and testing hi wall split units indoor / outdoor Air conditioner (hot and cold type) both complete with cordless remote control unit and within built air purifier, dehumidifier, air filter and dust filter for better indoor air quality with minimum BEE approved, 5 star rating, inverter type, ISEER 5, Electric driven single phase 220 volts, AC, 50HZ, R-410A/R-32 refrigerant of capacity 2 Ton, inverter type, noise level should be less than 45 DB including copper piping of adequate size and required length as directed duly insulated with suitable insulating material e.g. class 'O' Nitrile insulation of minimum 12mm thick for condensing unit, copper cable of suitable size for making electric connections, including necessary fixing arrangement (indoor unit at suitable place and height inside the room and outdoor unit at suitable place outside the room) complete as specified and as directed. Note:- (a) Suitable piping shall be provided of adequate length of size 5/8\\" for draining of condensate water from indoor unit. Cost of same shall deemed to be included in quoted rate. (b) Suitable Copper tubing in addition if required extra as per site requirement from indoor unit to outdoor unit shall be provided and cost of same shall to be included in quoted rate. (c) Cost for Metallic bracket and nut bolt for fixing indoor and outdoor unit including necessary cutting / grouting in walls by cutter and making good the surface in CM 1:3 and to the original finishes (white wash/colour wash/Distemper) shall deemed to be included in quoted rate. (d) Contractor shall submit original purchase voucher and Warranty card. Minimum warranty should be 1 year for complete product, 10 years for compressor, 5 years for condenser and PCB card after Installation and commissioning of complete unit. |
| 151 | Supply, installing, commissioning and testing hi wall split units indoor / outdoor Air conditioner (hot and cold type) both complete with cordless remote control unit and within built air purifier, dehumidifier, air filter and dust filter for better indoor air quality with minimum BEE approved, 5 star rating, inverter type, ISEER 5, Electric driven single phase 220 volts, AC, 50HZ, R-410A/R-32 refrigerant of capacity 1.5 Ton, inverter type, noise level should be less than 45 DB including copper piping of adequate size and required length as directed duly insulated with suitable insulating material e.g. class 'O' Nitrile insulation of minimum 12mm thick for condensing unit, copper cable of suitable size for making electric connections, including necessary fixing arrangement (indoor unit at suitable place and height inside the room and outdoor unit at suitable place outside the room) complete as specified and as directed. Note:- (a) Suitable piping shall be provided of adequate length of size 5/8\\" for draining of condensate water from indoor unit. Cost of same shall deemed to be included in quoted rate. (b) Suitable Copper tubing in addition if required extra as per site requirement from indoor unit to outdoor unit shall be provided and cost of same shall to be included in quoted rate. (c) Cost for Metallic bracket and nut bolt for fixing indoor and outdoor unit including necessary cutting / grouting in walls by cutter and making good the surface in CM 1:3 and to the original finishes (white wash/colour wash/Distemper) shall deemed to be included in quoted rate. (d) Contractor shall submit original purchase voucher and Warranty card. Minimum warranty should be 1 year for complete product, 10 year for compressor, 5 year for condenser and PCB card after Installation and commissioning of complete unit. |
| 152 | Supplying, installing, testing and commissioning automatic, servo controlled, indoor type, voltage stabilizer of capacity 5 kVA, single phase, IP55 protection, copper wound, naturally air cooled type, insulation class H, designed for input voltage of 160 V to 270 V and output voltage of 230 V ± 1%, voltage correction rate of 15 V per second, metallic body with lifting hook duly power coated, LCD display for Input and Output Voltage, frequency, current, Time Delay and Mains ON with under and over voltage protection, short circuit protection, surge protection all as per IS 8448: 1989 complete all as specified and as directed. |
| 153 | Earthing complete with GI slotted pipe of dia 40 mm bore, 3 mtr long (earth pit not less than 03meter deep below normal ground level) surrounded by adequate quality of charcoal dust and salt to packed thickness of 15 cm on all sides, connected to copper strip 30 x 3.15 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel and riveted / welded to earth plate at one end and other end of strip connected to transformer/GOD/Panel equipment body /test point with 02 Nos nuts, bolts including 25X3 mm flat iron clamp, nuts, bolts and washers and also including providing watering pipe 20 mm bore GI pipe medium grade from earth pit to top electrode and including funnel, wire mesh, copper lugs etc complete with earth pit in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and 40 mm thick PCC 1:2:4 type B1 cover complete all as shown in electrical plate No 3 of SSR Part-I including necessary excavation and earth work in any type of soil, returning filling and disposal of surplus soil to a distance not exceeding 50 metre complete all as specified and as directed.Note: - PCC Chamber shall be constructed at least 1.5 metre away from the earthing electrode and pipe for watering shall be provided in slanting manner. |
| 154 | Supply and fixing insulator in wall for aluminium strip with nut bolt complete all as specified and as directed. |
| 155 | Supply, installation, testing, commissioning of integrated type Heat Pump water heater with following components including installation testing and commissioning Outdoor Air cooled Integrated or split type Heat Pump with recirculation mode having minimum compressor capacity 3 HP, hermetically sealed with environment friendly refrigerant. At Rated heating Capacity, the heat pump must be able to deliver hot water at 65˚C (outlet temperature), at the rate not less than 120 litre per hour at minimum water inlet temperature of 4˚C and outlet temperature of 60˚C, and minimum 300 litre per hour in hybrid mode. At Rated heating Capacity, the heat pump must be able to deliver hot water at 65˚C (outlet temperature), at the rate not less than 120 litre per hour at minimum water inlet temperature of 4˚C and outlet temperature of 60˚C, and minimum 300 litre per hour in hybrid mode. The ratio of Rated output heating capacity to Rated Input Power should be such that COP of the machine is not less than 3.0 and must have Back-up heater power of not less than 12 kW and rated power input of not more than 2.5 kW. The heat pump shall have water storage tank of capacity (having internal glass lining) not less than 450 litre including following: -(i) Pressure Pump: pressure pump having SS 304 impellers electrical driven pump having flow of 5000 LPH and head 30 metre with all connected accessories coupled to motor, control panel, 1/3 phase,2900 RPM with 60 ltr of pressure vessel ( 1W + 1 S)(II) Horizontal Hydro pneumatic system SS 304 impellers, electrical driven pump having flow of 1 LPS, head 30 Mtr with all connected accessories control panel, coupled to motor, 1/3 phase ,2900 RPM with 60 ltr of pressure vessel ( 1 working + 1 standby) (iii) Electric water heater with glass lined insulated tank n-455 LTRS Water heater, having capacity 455 ltrs with blue diamond glass lined puff injected insulated tank having capacity of 455 ltrs, having glass coated electric heating element to avoid any scaling and 50 mm foam insulation. Heating tank should have the electrical element of at least 6 KW in total and should be glass lined complete as per OEM NOTE: (a) Heat pump should have all the safety protections like high/low voltage, high temperature, refrigerant leak, compressor overheat protection with operational noise level not more than 60 dbA. (b) Heat pump should have a user-friendly control panel to set the desired temperature with display of the actual temp also with flexibility of installing the same 15-30 m away from the heat pump. |
| 156 | Supply and fixing modular socket out let 25 Amp flush type (two module) with protector and accessories for AC complete with inner plate complete with one single pole MCB of capacity 20 Amps, 240 volts, AC supply complete all as specified and as directed. |
| 157 | Supply and fix concealed sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 4 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 4 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note 1- Two runs of 4 sqmm cable, one run of 4 sqmm cable and one run of conduit shall be measured and paid as one unit length. Note 2- Cost of cutting chase and making good shall be included in the quoted rate.) |
| 158 | Supply and fix refrigerator, electric driven (single phase), capacity 500 litres or more double door type complete all as specified and as directed. |
| 159 | Supply and fix Deep freezer, electric driven (single phase), capacity 500 litres double door type complete all as specified and as directed. |
| 160 | Supply, install, commissioning and testing of commercial Air curtain unit of size 46” X 78” for prevention of dust and conditioned air losses, single phase, 220 V, 50 HZ, made out of mild steel sheet as per IS 1079 or IS 513 of minimum thickness 1.25 mm finished with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer (oven baked) with mild steel sheet, 1.25 mm square perforated suction grills, Aluminium alloy fans and single phase electric motor, nozzles etc., complete with fittings and accessories so as to produce 1 - 1.5 m/sec air velocity at floor level for door opening complete all as specified and as directed. |
| 161 | Supply, install, commissioning and testing of commercial Air curtain unit of size 58” X 78” for prevention of dust and conditioned air losses, single phase, 220 V, 50 HZ, made out of mild steel sheet as per IS 1079 or IS 513 of minimum thickness 1.25 mm finished with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer (oven baked) with mild steel sheet, 1.25 mm square perforated suction grills, Aluminium alloy fans and single phase electric motor, nozzles etc., complete with fittings and accessories so as to produce 1 - 1.5 m/sec air velocity at floor level for door opening complete all as specified and as directed. |
| 162 | Supplying, installing, testing and commissioning silent kitchen chimney with filter less technology, aluminium body, noise level maximum 55 dB, 60 cm size, minimum 1352 cum per hour suction, operated on 240 volts, 3 Nos (steps) of speed, smart on & intel auto clean, black in colour complete all as specified and as directed. |
| 163 | Supply and fixing of flexible aluminium duct hose of size min 150mm (ID) for exhaust of Chimney on wall/ceiling complete all as specified and as directed. |
| 164 | Supply and fixing of RO (Reverse Osmosis) plant of capacity 1000 litres per hour with the following accessories and necessary pipe fitting with CPVC pipes: -(i) Row water Monoblock centrifugal pump - Min 1 hp with pressure 3.0 KG/sqcm - 01 No(ii) Sand filter with flow min rate 1.65 cum/hr with necessary valves - 01 No(iii) Activated Carbon filter with flow min rate 1.65 cum/hr with necessary valves - 01 Nos(iv) Chemical dosing system to dose anti scalant chemical with flow rate 0-6 litre per hour with diaphragm pump - Min 5 litre(v) Micron cartridge filter to filter micro particles of size 5µ with MOC housing - 02 Nos(vi) RO Module assembly - 01 No(vii) UV system of flow rate 1000 litre per hr -01 No(viii) Electric Instrument Control panel having on/off system, online TDS meter, Online pH meter, low pressure switch, pressure gauge-02 Nos, high pressure switch, Rota meter-02 Nos(ix) Tanks(a) 1000 litre Stainless steel tank for treated water with all necessary fitting and fixtures for inlet and outlet connection-01 No(b) 5000 litre HDPE double layer tank -01 No |
| 165 | Supplying, installing, commission and testing diesel Generating Set 160 KVA capacity including inbuilt retrofitting emission control device as per latest IS mounted acoustic weather proof as per CPCB IV plus (central pollution control Board) norms and noise level shall not exceed 75 decibels at distance of 1 metre and comprising of the following: -(A) Diesel Engine :- Diesel Engine developing not less than at NTP, 1500 RPM turbo charge water cooled engine inclusive of following standard accessories :-(i) Radiator Cooling system (ii) Direct coupled (iii) Flywheel to flexible coupling/closed coupled (iv) fly wheel housing with starter gear ring & coupling (v) Fuel houses (vi) Air cleaner (vii) Fuel and lub oil filter (viii) By pass filter (ix) Coolant inhabits (x) Fuel pump PTR type / in line mono block fuel injection pump (xi) Water pump (xii) Oil pump (xiii) Electric starter 24 volts DC (xiv) Industrial silencer (xv)Control push pull (xiv) Lub oil cooler |
| 166 | (B) Alternator: - Alternator suitable for continuous operation generating 160 KVA at 1500 RPM 415 volts at NTP 0.8 power factor 3 phase 50 Hz, self-excited & regulated with ball/roller bearings conforming to IS-4722.(C) Fuel tank as recommended by manufacturer with inlet and outlet connection and fuel level indicator. (D) Base frame fabricated form MS channel of suitable size and machined to ensure perfect alignment.(E) Two Nos maintenance free battery of 12 volts each of 180 AH lead acid type.(F) Supplying fixing, testing and commissioning of AMF of DG set and shall be complete with following: -(i) MCCB 4P 250A 25KA with adjustable over load (70 to 100%) adjustable short circuit - 01 No (ii) Adequate No of MCB of suitable size and rating (iii) Copper bus bar of suitable rating. (iv) Current transformer of suitable rating. (v) 4P contactor240V AC of suitable rating. (vi) Indicating lamps (RYB) (vii) Mushroom head push butten press to lock turn to release (viii) VAF meter (ix) DC Amp meter (x) 12 V DC automatic battery charger with built in trickle boost facility. (xi) 4-point alarm annunciator with built in hooter teast accept and reset push button. (xii) Solid state single element earth fault relay with contact. (xiii) Aux relay, coil voltage 12 V DCNote: - (a) Cost of suitable size of platform as per recommendations of manufacturer shall be provided with in overall cost quoted. (b) Any item left out for successful operation of AMF panel is deemed to be included in overall cost quoted.(c) Initial filling of lubricating oil/coolant and fuel required for testing of DG set shall be provided by the contractor without any extra cost. (d) All arrangement for testing of DG set shall be made by contractor with in overall cost quoted. (e) Pre-commissioning test shall be carried out by rep of Accepting Officer. Test for DG Set shall be carried out for duration of 12 hrs. |
| 167 | M & L for earthing complete with galvanised steel pipe electrode 40 mm nominal bore, medium grade, 10 metre length buried directly in ground with top edge of the pipe not less than 1.25 metres below normal ground level, connected to earthing lead of 32 mm X 6 mm GI strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 2 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed. |
| 168 | Supply and laying double wall corrugated pipe (DWC), non-metallic, Resistance to Compression : Type 450, Resistance to Impact: Normal, Resistance to Bending : Pliable, Resistance to External Influence: Ingress Protection : IP 67, Resistance against Corrosion : Without Protection, Resistance to Flame Propagation : Non Flame Propagating, Nominal outside diameter 63 mm, minimum inside dia 47 mm conforming to IS 16205 (Part 24) : 2017 complete all as specified and as directed. |
| 169 | Supplying, laying, connecting, jointing and testing in trenches 150 mm nominal dia ductile iron pressure pipe for water mains, centrifugally cast, spigot and socket ends (for push on joints), class K9 in any length with external protection of Metallic zinc with finishing layer of bituminous paint and internal linings of Portland cement (with or without additives) mortar with seal coat, all as per IS 8329: 2000 and including materials and jointing with rubber gasket for WA type of application and hardness class 50 for bulb and hardness class 80 for heel all as per IS 5382: 2018 and IS 12820: 2004 complete all as specified and as directed. |
| 170 | Supplying, laying, connecting, jointing and testing in trenches 100 mm nominal dia ductile iron pressure pipe for water mains, centrifugally cast, spigot and socket ends (for push on joints), class K9 in any length with external protection of Metallic zinc with finishing layer of bituminous paint and internal linings of Portland cement (with or without additives) mortar with seal coat, all as per IS 8329: 2000 and including materials and jointing with rubber gasket for WA type of application and hardness class 50 for bulb and hardness class 80 for heel all as per IS 5382: 2018 and IS 12820: 2004 complete all as specified and as directed. |
| 171 | Supplying, laying, connecting, jointing and testing in trenches 80 mm nominal dia ductile iron pressure pipe for water mains, centrifugally cast, spigot and socket ends (for push on joints), class K9 in any length with external protection of Metallic zinc with finishing layer of bituminous paint and internal linings of Portland cement (with or without additives) mortar with seal coat, all as per IS 8329: 2000 and including materials and jointing with rubber gasket for WA type of application and hardness class 50 for bulb and hardness class 80 for heel all as per IS 5382: 2018 and IS 12820: 2004 complete all as specified and as directed. |
| 172 | Material and labour for Cutting of existing CI/DI pipe line 200/150/100/80 mm bore for inserting and including tee of required size for taping in trenches including joints and jointing material complete all as specified and as directed.NOTE:- Necessary earth work, CI/DI fitting/ joints etc reqd to complete the job deemed to be included in the quoted rate. |
| 173 | M & L for construction of new valve pit/chamber of size 1500 mm (Length) X 1500 mm (Breadth) X 1500 mm (depth) including necessary earth work in any type of soil, PCC foundation M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate as in base concrete, brick work with sub class 'B' bricks, non-modular sizes as per IS 1077: 1992, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6, cement plaster 20 mm thick internally in two coats of (15 mm and 5 mm) in cement mortar 1:4, 3 mm thick mild steel sheet of any grade and designation as per IS 513: 2008 and IS 10748: 2004 welded with angle iron (40 mm X 40 mm X 6 mm) frame of structural steel, frame welded with angle iron (50 mm X 50 mm X 6 mm) frame of structural steel, welded to flat iron of size 150 mm X 50 mm X 6 mm of structural steel, fixed with bolt of 16 mm dia anchored with plate of size 100 mm X 100 mm X 3 mm of structural steel, bolt and anchored plate embedded in 250 mm thick PCC coping in M15(Nominal Mix) using 20 mm nominal size graded crushed stone aggregate, mild steel handle, grade E165 as per IS 15911: 2010 for structural steel with necessary, welding, riveting, bolting including painting exposed steel surfaces with two coats of bituminous paint and embedded surfaces of steel with two coats of tar, finishing exposed faces of concrete surfaces and plaster surfaces with three coats of white wash and all as per drawing No. BTD-811 Sheet Nos 1/2 and 2/2 of HQ CE Bathinda Zone complete all as specified and as directed. |
| 174 | M & L for construction of new valve pit/chamber of size 1000 mm (Length) X 1000 mm (Breadth) X 1000 mm (depth) including necessary earth work in any type of soil, PCC foundation M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate as in base concrete, brick work with sub class 'B' bricks, non-modular sizes as per IS 1077: 1992, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6, cement plaster 20 mm thick internally in two coats of (15 mm and 5 mm) in cement mortar 1:4, 3 mm thick mild steel sheet of any grade and designation as per IS 513: 2008 and IS 10748: 2004 welded with angle iron (40 mm X 40 mm X 6 mm) frame of structural steel, frame welded with angle iron (50 mm X 50 mm X 6 mm) frame of structural steel, welded to flat iron of size 150 mm X 50 mm X 6 mm of structural steel, fixed with bolt of 16 mm dia anchored with plate of size 100 mm X 100 mm X 3 mm of structural steel, bolt and anchored plate embedded in 250 mm thick PCC coping in M15(Nominal Mix) using 20 mm nominal size graded crushed stone aggregate, mild steel handle, grade E165 as per IS 15911: 2010 for structural steel with necessary, welding, riveting, bolting including painting exposed steel surfaces with two coats of bituminous paint and embedded surfaces of steel with two coats of tar, finishing exposed faces of concrete surfaces and plaster surfaces with three coats of white wash and all as per drawing No. BTD-811 Sheet Nos 1/2 and 2/2 of HQ CE Bathinda Zone complete all as specified and as directed. |
| 175 | Supply, installations, testing and commissioning of Compact Sub Station 630 KVA, HT Section: - 11 kV, 850 Amp, 0utdoor Type, VCB Horizontal Draw out Horizontal isolation floor mounting motorized panel with 230 v motor mechanism & 24v DC Shunt/Close coil with CT, PT, IDMT Relay, 8 Window Annunciator Model No. SI-801, Battery Power Pack with 7AH Battery & in-built charger for 24V Circuit and other fittings & accessories. -01 No. Potential Transformer – 3 Phase cast resin of ratio 11kV/110V, Class-0.5, 100VA with HT Primary Fuses-03 Nos Current Transformer –Cast resin Ratio: 60-30/5+5A, Core1:Cl.0.5, 15VA, Core2:Cl.5P10, 15V-01 Nos Protection Numerical 2OC + 1EF Relay 7 & Auxiliary Relay Micro Processed based Non-Directional IDMT -01 No. Indication Lamps VCB off / on / auto trip/ Trip circuit healthy/spring charge indication -01 set Metering Multifunction Meter -01 Set Transformer Section :- 630 KVA, 11/0.433 KV, 3 Phase, 50HZ, ONAN Cooled Oil immersed Copper Wound Step Down “BIS Marked & BEE Star Labelled” Transformer Complete with first filling of IS:335 ISI Marked Filtered & Dehydrated Transformer Oil, having 7 position Off-Circuit tap changer with tapping range +7.5% in steps of 2.5% each with all standard fittings & accessories including OTI, WTI & Marshalling Box. Transformer as per IS-1180(Part-1)-2014 EEL- 3 with amendment no.- 4 Losses @50% Load - 2460W Losses @100% Load - 6364WLT section: LT Panel comprising of LV Side Incomer–01 no. 850A 4P 415V 36KA MDO Air Circuit Breaker microprocessor based with O/L, S/C & E/F Protection. - RYB Indication -01 No. Ammeter, 850 A /5A LTCT CL : 1.0, Volt Meter Enclosure Section :- Space Heater with ON/OFF Switch and Thermostat, Single phase switch with socket, LT Cubical illumination Lamp with Door Limit switch and MCB’s for AC / DC Control -01 Set MS Steel Sheet enclosure suitable for Outdoor Installation with MS base channel Provision for receiving Incoming cables thro Bottom entry and outgoing -01 Set Provision for receiving Incoming through bus duct by bus bar and Outgoing through cable box bottom entry Excluding Termination Kit & Glands -01 Set Bus Bar – Aluminum-01 Set Earth Bus – Aluminium -01 Set Paint shade: Siemens Grey ( RAL 7032) -01 Set |
| 176 | (i) The transformer oil shall be PCB (polychlorinated biphenyls) free. Meeting new National Electric Code 2023, it is preferred that the transformer oil shall be mineral oil.(ii) GAS AND OIL ACTUATED (BUCHHOLTZ) RELAYS - Bucholz relay shall be provided with Mercury Free Float Switches.(iii)Cable Box - All cable boxes shall be provided with disconnecting chambers for easy removal of transformer during maintenance with-out cable dismantling. Termination req on both side HV & LV in cable box(iv)Stage inspection shall be offered for core & coil manufacturing. Tank pressure & vacuum withstand test to be conducted on 100% of order quantity. Temperature Rise, No Load Loss and Full Load Loss measurement shall be done at any NABL accredited laboratory on a random sample of each rating selected by purchaser.(v)Core material to be sourced directly from the CRGO/Amorphous producer or from their authorized/licensed importer. Transformer manufacturer shall be able to produce the mill’s test report of the core material used for this contract along with purchase invoice and bill of entry.(vi)The transformer manufacturer must have an in-house dust-free core cutting and processing unit in the same location as transformer manufacturing. The core shall be slit using automated machine and use of hand shear is not allowed. The Burr level should be less than 10 micron(vii)The winding shall be insulated with thermally upgraded paper (TUP) of thermal class B and use of normal kraft paper is not allowed to be used. Complete core and winding assembly shall be processed and dried using vapor phased drying (VPD) method only. No other method is acceptable.(viii)Transformer can monitor these data :- Water in oil, temperature, vibration, acoustic and RF noise.(ix)All routine and type tests shall be done in NABL accredited lab and Bidder should have in-house NABL accredited testing facility.(x) Core should be boltless step lap design and Bidder should have hydraulic core lifting facility to avoid any jerk at the time of core building.(xi))OEM should be BIS & BEE certified for all the rating of the transformer that are to be submitted(xii) To monitor these data • Load • Water content • Temperatures • Continuous Partial Discharge (PD) • Vibration, in Transformer is required. This Transformer is req for critical load, hence monitoring of PD and water content, vibration etc in Transformer is required to be monitor. The vendor should inform if riskparameters exceed level specified by IEEE and CIGRE standards and make recommendations for necessary action. |
| 177 | S&F Switch air break, gang operated outdoor, Horizontal operated type, HT 11 KV, Triple pole,400 Amps, 3 insulator per phase, tilting/rocking horizontal type, with fixed contacts of phosphorous bronze and moving contacts of copper, manually operated from ground level with operating mechanism including GI tubing medium grade 25 mm bore operating rod, pad locking arrangements, MS arcing horns, flexible braiding earthing blades, rod and contacts without drop out fuse assembly and jumpers with Mink conductor line, taps, clamps, colour coated HT sleeves and fittings suitable for horizontal mounting, complete all as specified and as directed. |
| 178 | Supply and laying double wall corrugated pipe (DWC), non-metallic, Resistance to Compression : Type 450, Resistance to Impact: Normal, Resistance to Bending : Pliable, Resistance to External Influence: Ingress Protection : IP 67, Resistance against Corrosion : Without Protection, Resistance to Flame Propagation : Non Flame Propagating, Nominal outside diameter 120 mm, minimum inside dia 90 mm conforming to IS 16205 (Part 24) : 2017 complete all as specified and as directed. |
| 179 | Supply and laying double wall corrugated pipe (DWC), non-metallic, Resistance to Compression : Type 450, Resistance to Impact: Normal, Resistance to Bending : Pliable, Resistance to External Influence: Ingress Protection : IP 67, Resistance against Corrosion : Without Protection, Resistance to Flame Propagation : Non Flame Propagating, Nominal outside diameter 63 mm, minimum inside dia 47 mm conforming to IS 16205 (Part 24) : 2017 complete all as specified and as directed. |
| 180 | M & L for boring of holes under main road pavment,hard standing by trenchless technology using ultra sound tecnique and necessary machine for accomodet upto 40mm bore GI tube (light grade) in the drilled holes,returning ,filling in the end working space including removal of surplus soil and making good the surface complete all as specified and as directed.Note : GI pipe light grade shall be measured and paid separately. |
| 181 | Supply and fix compact air insulated bus bar trunking system with aluminium busbar 1250 Amps,50 KA breaking capacity,IP 54 protection complete all as specified and as directed. |
| 182 | Supply & Fixing LED security light fitting 70watt high pressure die cast aluminium housing, heat resistant toughened glass with frame, IP66 protection comlete with lamp & connected items and connection with suitable cable from ceiling rose to light fitting and fixing on GI pipe bracket made out of suitable dia GI pipe medium grade 1.2mtr long bent to shape and fixed on wall with flat iron clamps, nut, bolts washer etc complete all as specified and as directed. |
| 183 | Supply and erect factory made 7 meter long hot dip galvanized (as per relevant IS with average coating thickness 65 micron) octagonal poles conform to IS-2062/ BSEN 10025 with 155 mm dia at bottom and 70 mm dia at top A/F made up of 3 mm thick HT sheet along with foundation type base plate of size 250 mm X 250 mm X 16 mm, foundation bolt 4 Nos of M20 X 600 mm high 'J' type EN8 grade, including 1 meter long hot dip galvanized single arm (swan neck) bracket made up of 40 NB dia GI pipe and including excavation, earth work, PCC (1:2:4) type B1 for foundation and grouting the bolts as per manufacturer’s instructions including marking pole number in letters & figures of size not less than 10 cm height with red colour enamel paint complete all as specified and as directed. Note: - (i) Srl number will be issued by Engineer-in-Charge. |
| 184 | Supply and fixing LED Post Top light fitting of 40W decorative design, Glare-free and better uniformity compete fitting all with accessories and LED lamp, fixing on and including 50mm dia GI pipe light grade of length 2.5 mtr embeded in PCC block of size 0.3x0.3x0.5m made with PCC (1:2:4) type B-2 using 20 mm graded crushed stone aggregate, including making electric connection with suitable size of wire, complete fitting with all accessories and following specifications complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficiency of luminaire should be minimum 100 lumen per watt. (b) Input voltage range : 140 to 270 volts. (c) Temp operating range : Minus 10*C to plus 50*C (d) Power factor : Minimum 0.95 (e) THD : Max 10% (f) CRI : More than 70 and CCT : 5700K (g) IP rating : IP 65 (h) IK rating : minimum IK 07 (j) Built in potted LED Driver of the make as of the luminaire. (k) LED driver should e complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (l) Surge protection 10kV (inbuilt +extended) (m) Lens - High Efficiency wide angle lens. (n) BIS approved fixtures and driver (o) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily) |
| 185 | Supply and fix time switches astro type (having longitude and latitude of phase of 32A rating with contracted fitted inside steel enclosure complete all as specified and as directed. |
| 186 | M & L for steel tubular swaged pole 410 SP-55 (11.0 metre long) including CI base plate, finial taper plug, bolts, nuts & screws as per IS 2713 Part -I & II including preparing and painting on steel tubular swaged pole 410 SP-22 (8.50 metre long) complete all as specified and as directed, comprising the following: -(a) Two coats of synthetic enamel paint in white colour over a coat of primer on PCC coping (b) Making 4 Nos of strips of 30 cm wide in alternate red and white colour using two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer (c) Providing 30 cm wide retro reflective sheet, grade 1, pressure bonding type, red colour as per IS 14221: 1995 (d) Two coats of synthetic enamel paint in red colour over a coat of primer from top of electric pole to downward upto 1 metre length including cross arms, GI brackets etc. (e) Writing pole number and voltage level encompassed by circle of suitable dia using two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer (the colour of base shall be black and the colour of font shall be white). Number and voltage level shall be handwritten, and circle shall be stencilled. (f) Painting with two coats of aluminium paint over a coat of aluminium red oxide primer on remaining exposed portions |
| 187 | M & L for earthing complete with galvanised steel pipe electrode 40 mm nominal bore, medium grade, 10 metre length buried directly in ground with top edge of the pipe not less than 1.25 metres below normal ground level, connected to earthing lead of 4 mm dia GI strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 2 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed. |
| 188 | Supply and fix metal oxide surge arrester without gap for AC system as per IEC 60099-4: 2014, outdoor type, polymer housing, single column and single phase construction, distribution class, medium duty, nominal discharge current 5 kA, repetitive charge transfer rating (Qrs) more than 0.2 C, thermal charge transfer rating (Qth) more than 0.7 C, nominal system voltage 11 kV, highest system voltage 12 kV, rated voltage of arrester 9 kV, continuous operating voltage 7.2 kV, temporary overvoltage (10.50 kV for 1 s, 9.90 kV for 10 s, 9.35 kV for 100 s), rated short circuit current 20 kA, low short circuit current 600 A, insulation withstand level (lightning impulse voltage 1.2/ 50 µs) 75 kV, lightning impulse residual voltage (8/20 µs) at nominal discharge current maximum 22 kV, high current impulse withstand capability (4/10 µs) 65 kA, minimum creepage distance 300 mm complete all as specified and as directed. |
| 189 | Supply, installation, commissioning and testing of factory made cubical type LT panel Board of Suitable size (CPRI approved) indoor type dust proof, vermin proof with IP 54 protection made out of CRCA sheet 2.0 mm thick synthetic enamel paint over a coat of red oxide primer, fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including locking arrangements including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with aluminium bus bar capacity 2000 Amps 04 Nos Three Phase and neutral (TPN) (in Separate chamber), bus bar fixed on epoxy coated insulator and provision with 1100 volt grade heat shrinkable type sleeves and housed in independent chamber having access both from front and back side, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 40 x40 x5mm, legs shall be grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :- |
| 190 | (i) Supply and fix ACB 4 Pole, 415 V, Manual Draw out type with microprocessor release of capacity 1250 Amps – 01 Nos (incoming)(ii) Supply and fix 4 Pole MCCB 400 Amp, 50 Hz, 415 V with rupturing capacity, Thermal magnetic relay adjustable type 50 KA. – 01 Nos (Outgoing)(Panel No-1)(iii) Supply and fix 4 Pole MCCB 320 Amp, 50 Hz, 415 V with rupturing capacity, Thermal magnetic relay adjustable type 50 KA. – 01 Nos (Outgoing) (Panel No-2)(iv) Supply and fix 4 Pole MCCB 250 Amp, 50 Hz, 415 V with rupturing capacity, Thermal magnetic relay adjustable type 36 KA. – 01 Nos (Outgoing) (AC Plant)(v) Supply and fix 4 Pole MCCB 200 Amp, 50 Hz, 415 V with rupturing capacity, Thermal magnetic relay adjustable type 25 KA. – 01 Nos (Outgoing) (Panel No 3)(vi) Supply and fix 4 Pole MCCB 125 Amp, 50 Hz, 415 V with rupturing capacity, Thermal magnetic relay adjustable type 25 KA. – 01 Nos (Outgoing) (Panel No4)(vii) Supply and fix MCB 2 Pole (SPN), 32 Amp, 10kA, B Curve rating suitable for 240 Volts (Outgoing). – 01 Nos(viii) Space for MCCB of - 02 Nos (ix) Digital Voltmeter with built in selector switch 0-500Volts -1No(x) Digital Ammeter with built in selector switch 0-1500 amps with suitable CTs -1No(xi LED Indicated Lamp (R, Y, B) (Set of Three) |
| 191 | Supply, installation, commissioning and testing of factory made cubical type LT panel Board of Suitable size (CPRI approved) out door type dust proof, vermin proof with IP 54 protection made out of CRCA sheet 3.15 mm thick synthetic enamel paint over a coat of red oxide primer, fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including locking arrangements including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with aluminium bus bar capacity 600 Amps 04 Nos Three Phase and neutral (TPN) (in Separate chamber), bus bar fixed on epoxy coated insulator and provision with 1100 volt grade heat shrinkable type sleeves and housed in independent chamber having access both from front and back side, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 40 x40 x5mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :- (LT Panel No 1) |
| 192 | (i) Supply and fix 4 Pole MCCB 400 Amp, 50 Hz, 415 V with rupturing capacity, Thermal magnetic relay adjustable type 50 KA. – 01 Nos (Incoming)(ii) Supply and fix 4 Pole MCCB 125 Amp, 50 Hz, 415 V with rupturing capacity, Thermal magnetic relay adjustable type 16/18 KA. – 01 Nos( Outcoming)(ii) Supply and fix 4 Pole MCCB 100 Amp, 50 Hz, 415 V with rupturing capacity, Thermal magnetic relay adjustable type 16/18 KA. – 01 Nos( Outcoming)(iii) Supply and fix 4 Pole MCCB 63 Amp, 50 Hz, 415 V with rupturing capacity, Thermal magnetic relay adjustable type 16/18 KA. – 02 Nos( Outcoming)(iv) Supply and fix 4 Pole MCCB 40 Amp, 50 Hz, 415 V with rupturing capacity, Thermal magnetic relay adjustable type 16/18 KA. – 02 Nos( Outcoming)(v) Supply and fix 4 Pole MCCB 32 Amp, 50 Hz, 415 V with rupturing capacity, Thermal magnetic relay adjustable type 16/18 KA. – 01 Nos (Outcoming)(vi) Supply and fix MCB 2 Pole (SPN), 25 Amp, 10kA, B Curve rating suitable for 240 Volts (Outgoing ). – 05 Nos(vii) Space for MCCB of - 01 Nos (Spare)(viii) Space for MCB SPN of - 02 No (Spare) (ix) Digital Voltmeter with built in selector switch 0-500Volts -1No(x) Digital Ammeter with built in selector switch 0-500 amps with suitable CTs -1No(xi) LED Indicated Lamp (R, Y, B) |
| 193 | Supply, installation, commissioning and testing of factory made cubical type LT panel Board of Suitable size (CPRI approved) out door type dust proof, vermin proof with IP 54 protection made out of CRCA sheet 3.15 mm thick synthetic enamel paint over a coat of red oxide primer, fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including locking arrangements including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with aluminium bus bar capacity 500 Amps 04 Nos Three Phase and neutral (TPN) (in Separate chamber), bus bar fixed on epoxy coated insulator and provision with 1100 volt grade heat shrinkable type sleeves and housed in independent chamber having access both from front and back side, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 40 x40 x5mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :- (LT Panel No 2) |
| 194 | (i) Supply and fix 4 Pole MCCB 320 Amp, 50 Hz, 415 V with rupturing capacity, Thermal magnetic relay adjustable type 50 KA. – 01 Nos (Incomer) (ii) Supply and fix 4 Pole MCCB 125 Amp, 50 Hz, 415 V with rupturing capacity, Thermal magnetic relay adjustable type 16/18 KA. – 02 Nos (Outcoming)(iii) Supply and fix 4 Pole MCCB 63 Amp, 50 Hz, 415 V with rupturing capacity, Thermal magnetic relay adjustable type 16/18 KA. – 01 Nos (Outcoming)(iv) Supply and fix 4 Pole MCCB 32 Amp, 50 Hz, 415 V with rupturing capacity, Thermal magnetic relay adjustable type 16/18 KA. – 01 Nos (Outcoming)(v) Supply and fix 4 Pole MCCB 25 Amp, 50 Hz, 415 V with rupturing capacity, Thermal magnetic relay adjustable type 16/18 KA. – 03 Nos (Outcoming)(vi) Supply and fix MCB 2 Pole (SPN), 25 Amp, 10kA, B Curve rating suitable for 240 Volts (Out going ). – 01 Nos(vii) Space for MCCB of - 01 Nos (Spare )(viii) Space for MCB SPN of - 02 No (Spare) (ix) Digital Voltmeter with built in selector switch 0-500Volts -1No(x) Digital Ammeter with built in selector switch 0-500 amps with suitable CTs -1No(xi) LED Indicated Lamp (R, Y, B) |
| 195 | Supply, installation, commissioning and testing of factory made cubical type LT panel Board of Suitable size (CPRI approved) out door type dust proof, vermin proof with IP 54 protection made out of CRCA sheet 3.15 mm thick synthetic enamel paint over a coat of red oxide primer,fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including locking arrangements including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with aluminium bus bar capacity 300 Amps 04 Nos Three Phase and neutral (TPN) (in Separate chamber), bus bar fixed on epoxy coated insulator and provision with 1100 volt grade heat shrinkable type sleeves and housed in independent chamber having access both from front and back side, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 40 x40 x5mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :- (LT Panel No 3) |
| 196 | (i) Supply and fix 4 Pole MCCB 200 Amp, 50 Hz, 415 V with rupturing capacity, Thermal magnetic relay adjustable type 25 KA. – 01 Nos (Incoming)(ii) Supply and fix 4 Pole MCCB 100 Amp, 50 Hz, 415 V with rupturing capacity, Thermal magnetic relay adjustable type 16/18 KA. – 01 Nos (Outcoming)(iii) Supply and fix 4 Pole MCCB 63 Amp, 50 Hz, 415 V with rupturing capacity, Thermal magnetic relay adjustable type 16/18 KA. – 01 Nos (Outcoming)(iv) Supply and fix MCB 2 Pole (SPN), 25 Amp, 10kA, B Curve rating suitable for 240 Volts (Outgoing). – 04 Nos(v) Space for MCCB of- 01 Nos (Spare)(vii) Space for MCB SPN of- 02 No (Spare) (viii) Digital Voltmeter with built in selector switch 0-500Volts -1No(ix) Digital Ammeter with built in selector switch 0-300 amps with suitable CTs -1No(x) LED Indicated Lamp (R, Y, B) |
| 197 | Supply, installation, commissioning and testing of factory made cubical type LT panel Board of Suitable size (CPRI approved) out door type dust proof, vermin proof with IP 54 protection made out of CRCA sheet 3.15 mm thick synthetic enamel paint over a coat of red oxide primer,fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including locking arrangements including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with aluminum bus bar capacity 100 Amps 04 Nos Three Phase and neutral (TPN) (in Separate chamber), bus bar fixed on epoxy coated insulator and provision with 1100 volt grade heat shrinkable type sleeves and housed in independent chamber having access both from front and back side, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 40 x40 x5mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :- (LT Panel No 4) |
| 198 | (i)Supply and fix 4 Pole MCCB 125 Amp, 50 Hz, 415 V with rupturing capacity, Thermal magnetic relay adjustable type 25 KA. – 01 Nos (incoming)(ii) Supply and fix 4 Pole MCCB 63 Amp, 50 Hz, 415 V with rupturing capacity, Thermal magnetic relay adjustable type 16/18 KA. – 01 Nos (Outcoming)(iii) Supply and fix MCB 2 Pole (SPN), 32 Amp, 10kA, B Curve rating suitable for 240 Volts (Outgoing). – 01 Nos(iv) Supply and fix MCB 2 Pole (SPN), 25 Amp, 10kA, B Curve rating suitable for 240 Volts (Outgoing). – 04 Nos(v) Space for MCCB of- 01 Nos (Spare)(vi) Space for MCB SPN of- 02 No (Spare) (vii) Digital Voltmeter with built in selector switch 0-500Volts -1No(viii) Digital Ammeter with built in selector switch 0-500amps with suitable CTs -1No(ix) LED Indicated Lamp (R, Y, B) |
| 199 | Supply, installation, testing and commissioning of Automatic Power Factor Correction (APFC) capacitor panel having aggregate capacity 300 KVAR in 7 stage with microprocessor based control, factory made indoor type, platform mounted, suitable for 440 volt, 3 phase, 4 wire, 50 Hz AC supply system having duly insulated copper bus bars, dust and vermin proof, IP-54 class protection and made of 2.00mm CRCA MS Sheet and 40x40x5mm thick angle frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, both side opening type, with aprons for cable entry, with double door shutter and locking arrangement (including provn of 65mm Godrej (Novtal) lock with two keys, internal wiring with PVC insulated, solid copper conductor, FRLS cables, SI-694 marked of adequate size but not less than 2.5 sqmm complete with following components and complete all as specified and as directed :- (Incoming)(a) MCCB 4 pole 630 Amp 36 kA with adjustable thermal setting ICS=ICU 415V-01 No Outgoing: -(i) Power factor corrector relay 6 stage Microprocessor based, modular type intelligent APFC relay capable of having self-adjustment to any capacitor value suitable to maintain power factor between 0.85 to 0.95 with digital indication of power factor, preset parameters and having in built capability of indication and elimination of defective capacitor steps-01 Nos(ii) Power Capacitor MPP-H type - (a) 100 KVAR -01 Nos (b) 50 KVAR -02 Nos (c) 25 KVAR -04 Nos(iii) Capacitive duty contactor suitable for srl (ii) above (iv) MCCB TP 250 Amp-01 Nos (v) MCCB TP 125 Amp -03 Nos (vi) MCB TP 63 Amp - 04 Nos (vii) Protection Fuse 16 amp HRC type (viii) Auto / Manual Selector switch (ix) ON-OFF Push Button (x) Aux Contacts 4 No + 4 NC of L&T or equivalent in Crompton Greaves/Siemens/ABB - 8 Set (xi) One Amp Meter 850 Amp with CT's & one volt meter 0-500 V (xii) Indicating light for capacitor ON/OFF position |
| 200 | Supply and fixing Hydrocyclone filter with 2 solid flange size of 75mm dia and capacity of 30 m³/hr for head control unit in drip irrigation system IS 14743:1999 with all connected accessories Complete all as specified and directed by Engineer-In-Charge |
| 201 | Supply and fix PP manifold of size 75mm for Filter Unit of Drip and Pop-up system with connected accessories Complete all as specified and directed by Engineer-In-Charge |
| 202 | Supply, fixing Ventury with Ferttigation Manifold assemble size of 63 mm for head control unit IS: 14483:1997 with all acessories Complete all as specified and directed by Engineer-In-Charge |
| 203 | Supply and fixing Air relese valve (plastic) size of 25 mm dia for head control unit in dirip irrigation system. Complete all as specified and directed by Engineer-In-Charge |
| 204 | Supply and fixing Pressure gauge (glycerine) cap of 0-7 kg/cm² size of 63mm dia for head control unit in dirip irrigation system Complete all as specified and directed by Engineer-In-Charge |
| 205 | Supply and fixing Screen filter (plastic) with 2 solid flange size of 75 mm dia and capacity of 30 m³/hr for head control unit in drip irrigation system IS : 12785:1994 Complete all as specified and directed by Engineer-In-Charge |
| 206 | Supply and fixing PP control valve size of 75mm for controlling water in storage tank for drip irrigation system. Complete all as specified and directed by Engineer-In-Charge |
| 207 | S & F 80 mm gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed to pipe complete all as specified and as directed. |
| 208 | M & L for construction of new valve pit/chamber of size 750 mm (Length) X 750 mm (Breadth) X 750 mm (depth) including necessary earth work in any type of soil, PCC foundation M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate as in base concrete, brick work with sub class 'B' bricks, non-modular sizes as per IS 1077: 1992, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6, cement plaster 20 mm thick internally in two coats of (15 mm and 5 mm) in cement mortar 1:4, 3 mm thick mild steel sheet of any grade and designation as per IS 513: 2008 and IS 10748: 2004 welded with angle iron (40 mm X 40 mm X 6 mm) frame of structural steel, frame welded with angle iron (50 mm X 50 mm X 6 mm) frame of structural steel, welded to flat iron of size 150 mm X 50 mm X 6 mm of structural steel, fixed with bolt of 16 mm dia anchored with plate of size 100 mm X 100 mm X 3 mm of structural steel, bolt and anchored plate embedded in 250 mm thick PCC coping in M15(Nominal Mix) using 20 mm nominal size graded crushed stone aggregate, mild steel handle, grade E165 as per IS 15911: 2010 for structural steel with necessary, welding, riveting, bolting including painting exposed steel surfaces with two coats of bituminous paint and embedded surfaces of steel with two coats of tar, finishing exposed faces of concrete surfaces and plaster surfaces with three coats of white wash and all as per drawing No. BTD-811 Sheet Nos 1/2 and 2/2 of HQ CE Bathinda Zone complete all as specified and as directed. |
| 209 | Supply only PVC flexible garden pipe 20 mm dia for connecting sprinkler system to GI water posts complete all as specified and directed by Engineer - in - Charge. |
| 210 | Supply only portable impact sprinkler (brass) system ISI marked on MS Tripod base with 20 mm dia inlet full, 360 degree coverage and adjustable deflactor flap to adjust throw distance upto 80 feet and height adjustable complete all as specified and directed by Engineer - in - Charge. |
| 211 | Supply, fixing and testing of Submersible pumpset 1.5 HP capacity with supply voltage 415 V, three phase, 50 HZ,with 3000RPM in stainless steel body with inlet filter driven by suitable for operation with operating head 28-14 Mtr and having capacity to discharge water 1.9-0.4 LPS with suction and discharge flanged suction 40 X 40 mm including suitable size of strainer mounted on suitable for existing surface with MS bolts, nuts of required size and necessary control valves, properly connected with suction and delivery water line, including three core copper conductor cable from starter panel to motor terminal as per suitable size including all connected accessories all as specified and directed by Engineer -In -Charge. |
| 212 | Supply, fixing and testing of submersible Pumpset 5 HP capacity with supply voltage 415 V, three phase, 50 HZ,with 3000RPM in stainless steel body with inlet filter driven by suitable for operation with operating head 28-14 Mtr and having capacity to discharge water 1.9-0.4 LPS with suction and discharge flanged suction 40 X 40 mm including suitable size of strainer mounted on suitable for existing surface with MS bolts, nuts of required size and necessary control valves, properly connected with suction and delivery water line, including three core copper conductor cable from starter panel to motor terminal as per suitable size including all connected accessories all as specified and directed by Engineer -In -Charge. |
| 213 | Supply, install, testing and commissioning factory made and tested (including CPRI type test certified) LT feeder pillar box KIOSK, outdoor type, suitable for 415 Volts, 3 Phase & neutral, 4 wire, 50 Hz, AC supply system, protection class IP-65, having bus bar chamber with insulated aluminium bus bars of 63 Amps rating in colour code RYB with 3 phase & neutral installed on insulators. The panel shall be dust and vermin proof, made out of 3.15mm thick CRCA MS sheet and 50X50X6mm thick angle iron for base frame work. The complete feeder pillar box shall be powder coated inside & outside (of approved shade) and internal wiring with PVC insulated stranded copper conductor FRLS cables of appropriate size with proper ferrule & cable gland, front openable with aprons for cable entry with door shutter including locking arrangement as per manufacturers, all as specified and directed by Engineer -In-Charge. The scope of work includes supply & fixing of the following: - (a) Incoming MCCB, 4 Pole, 63 Amps rating, rupturing capacity 25 kA, 415 Volt grade, AC, 50 Hz, Magnetic fixed type – 01 No. (b) Outgoing MCCB, 3 Pole, 16 Amp rating, rupturing capacity 16 kA, 415 Volt grade, AC, 50 Hz, Magnetic fixed type – 01 Nos (c) Digital Volt meter 0-500 Volts with selector switch – 01 No.(d) Digital Ampere meter 0-50 Amp with selector switch – 02 Nos. (e) Indicating lamp RYB “LED” type complete – 01 Set(f) Single phase preventer suitable up to 2 HP submersible pump set each.(g) Star delta starter in sheet steel enclosure, suitable for 1.5 HP electric Motor, 3 phase, 415-volt, 50 Hz – 02 No. (h) Space for mounting for Star delta starter 1.5 HP electric Motor, 3 phase, 415-volt, 50 Hz – 01 No. |
| 214 | Supply, install, testing and commissioning factory made and tested (including CPRI type test certified) LT feeder pillar box KIOSK, outdoor type, suitable for 415 Volts, 3 Phase & neutral, 4 wire, 50 Hz, AC supply system, protection class IP-65, having bus bar chamber with insulated aluminium bus bars of 63 Amps rating in colour code RYB with 3 phase & neutral installed on insulators. The panel shall be dust and vermin proof, made out of 3.15mm thick CRCA MS sheet and 50X50X6mm thick angle iron for base frame work. The complete feeder pillar box shall be powder coated inside & outside (of approved shade) and internal wiring with PVC insulated stranded copper conductor FRLS cables of appropriate size with proper ferrule & cable gland, front openable with aprons for cable entry with door shutter including locking arrangement as per manufacturers, all as specified and directed by Engineer -In-Charge. The scope of work includes supply & fixing of the following (a) Incoming MCCB, 4 Pole, 25 Amps rating, rupturing capacity 25 kA, 415 Volt grade, AC, 50 Hz, Magnetic fixed type – 01 No. (b) Outgoing MCCB, 3 Pole, 16 Amp rating, rupturing capacity 16 kA, 415 Volt grade, AC, 50 Hz, Magnetic fixed type – 02 Nos (One working and one spare) (For 5 HP Pump) (c) Digital Volt meter 0-500 Volts with selector switch – 01 No.(d) Digital Ampere meter 0-50 Amp with selector switch – 02 Nos(e) Indicating lamp RYB “LED” type complete – 01 Set(f) Single phase preventer suitable for 5 HP submersible pump set each.(g) Star delta starter in sheet steel enclosure, suitable for 5 HP electric Motor, 3 phase, 415-volt, 50 Hz – 02 Nos (g) Space for mounting for Star delta starter 5 HP electric Motor, 3 phase, 415-volt, 50 Hz – 01 No |
| 215 | Supply and fixing PVC service saddle of 63X1/4 mm dia including MT and FT for water distribution line in dirip irrigation system complete all as specified and directed by engineer -In-Charge. |
| 216 | Supply and fixing PVC Control valve size of 63 mm dia for head control unit sub distribution line in dirip irrigation system and all connected accessories complete all as specified and directed |
| 217 | Supply and fixing Flush valve size of 75x63 mm dia for sub distribution line in dirip irrigation system complete all as specified and directed by engineer -In-Charge. |
| 218 | Supply and fixing PVC Control valve size of 75 mm dia for head control unit sub distribution line in dirip irrigation system and all connected accessories complete all as specified and directed. |
| 219 | Supply and fixing Swing joint full three way adjustability including neight for Pop-Up Impact Sprinkler, bush with connected accessories, durable polyethylene construction for 3/4\\" size. Complete all as specified and directed by Engineer -In-Charge. |
| 220 | Supply and fixing PVC pipe (4 kg/cm²) IS ; 4984:2016, size of 75 mm for Main line in Pop-up and Drip irrigation system including all connected accessories. (ie Elbow,FTA,MTA,Tee,Solvent, clamps etc) all as specified and directed by Engineer -In- Charge. |
| 221 | Supply and fixing PVC pipe (6 kg/cm²) IS ; 4985:2000 size of 63 mm dia for sub distribution line in dirip irrigation system and including all connected accessories (ie Socket,Bend,Elbow, Tee, Reducer,connector, Solvent,clamps etc) all as specified and directed by Engineer -In- Charge. |
| 222 | Supply and fixing Dripper cap 8 LPH for dirip irrigation system and connected accessories complete all as specified and directed by engineer -In-Charge. |
| 223 | Supply and fixing Plain lateral 2.5 kg/cm², class II size of 32 mm dia, for water distribution line in dirip irrigation system and including all connected accessories (ie Socket,Bend,Elbow,Tee, Reducer, connector, suitable size Grommat Joiner 16mm take off, End cap, etc) all as specified and directed by Engineer -In- Charge. |
| 224 | Supply and fixing Plain lateral 2.5 kg/cm², class II size of 16mm dia,online for water distribution line in drip irrigation system including all connected accessories (ie Grommat, Lateral cock, End cap for connection in UPVC/Plain lateral pipe etc) (For trees) all as specified and directed by Engineer -In- Charge. |
| 225 | Supply and fixing Emitting pipe of dia 16 mm, discharge 2 LPH, dripper spacing 30 cm. 2,5 kg/cm², IS:13488, including all connected accessories (ie Socket,Bend,Elbow,Tee,connector, suitable size Grommat,Joiner etc.(for hedge) all as specified and directed by Engineer -In- Charge. |
| 226 | Supply and fixing Pop-Up Impact sprinkler of heavy duty Plastic, adjustable to full-circle or Part circle with diffuser screw for fine drop lets and throw control, inlet size 3/4\\", having radious of throw up to 12 mtrs at pressure 4 kg/cm² omplete all as specified and directed by engineer -In-Charge. |
| 227 | Supply and fixing PVC End cap size of 63 mm dia for water distribution line in Pop-Up irrigation system and all including complete accessories all as specified and directed. |
| 228 | M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 25 mm X 4 mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed. |
| 229 | Supply and fix Rotational moulded HDPE water (storage) tank of 5000 Ltrs capacity (Cylindrical vertical tank with closed top) hoisted on roof/ lowered underground and fixed in position including making necessary arrangements for fixing inlet, outlet overflow pipe and provision of washout pipe with and including circular platform of height 30Cm below the tank and base 25Cm more than the external dia of tank casted into two layers of PCC with first layer of 15Cm thickness of PCC 1:2:4 type B2 using with 40 mm graded aggregate and second top layer 15Cm thickness in PCC 1:3:6 type C1 using with 20 mm graded aggregate with smooth finish to exposed concrete surfaces including necessary form work etc complete all as specified and as directed by Engineer-In-ChargeNote :- (i) The water storage tank shall be triple layer, HDPE tank moulded to seamless perfection of rotation moulding process. The tanks shall be manufactured only from FDA approved special grade poly Ethelene and shall be certified fit for portable water including necessary foundation for placing the water tank. Complete all as specified and directed. (ii) HDPE storage tank shall be as per IS- 12701.(iii) Necessary Earth work shall be measured and paid separately |
| 230 | Supply, install, commissioning & testing 6 Sqmm single core multistranded copper conductor PVC insulated and sheathed copper cable 1100 Volts grade including all connection arrangements complete all as specified & as directed by Engineer -in-charge Note :- Cable connection from Star delta starter control panel to motor terminals |
| 231 | M & L for concealed point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.) |
| 232 | M & L for concealed point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium protection stove enamelling rigid steel conduit as per IS 9537 (Part-II): 1981 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.) |
| 233 | M & L for point wiring for one 3 pin/ 5 pin/ 6 pin 5/15 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.) |
| 234 | M & L for concealed point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on the same board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.) |
| 235 | M & L for concealed point wiring for one light controlled by two 2-way switches complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.) |
| 236 | M & L for concealed point wiring for one 3 pin/ 5 pin 15 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 4 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 4 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.) |
| 237 | S&F BLDC Exhaust fan, 300 mm sweep heavy ABS body, 240 volts 50 Hz Single Phase, min 33 Watt, 1585 RPM, 700 CMH complete with lovers shutters and mounted in suitable opening arrangement in wall and connecting up including three core PVC insulated PVC sheathed copper conductor flexible cable 1.5mm drawn in flexible PVC conduit and fixed by using 4 Nos, 200 mm long 12 mm dia bolts nuts and washers and grouted in wall in cement mortar (1:3) complete all as specified and as directed |
| 238 | S&F BLDC Exhaust fan, 400 mm sweep heavy ABS body, 240 volts 50 Hz Single Phase, min 33 Watt, 1585 RPM, 700 CMH complete with lovers shutters and mounted in suitable opening arrangement in wall and connecting up including three core PVC insulated PVC sheathed copper conductor flexible cable 1.5mm drawn in flexible PVC conduit and fixed by using 4 Nos, 200 mm long 12 mm dia bolts nuts and washers and grouted in wall in cement mortar (1:3) complete all as specified and as directed |
| 239 | S & F double door MCB Distribution board of sheet metal enclosure, single pole and neutral, 6 way with 100 Amps rated bus bar, 240 volt, IP42 protection grade and fixed with PVC plug and screws and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed. |
| 240 | Supply and fixed Distribution Board Single Door 4 way SPN made out of CRCA mild steel sheet surface with insulated material like polyester or with powder coating surface mounting suitable for incorporation of MCB’s and isolators etc complete all as specified and as directed. |
| 241 | S & F TPN distribution board 4 way vertical type double door made out of CRCA mild steel sheet surface with insulated material like polyester or with powder coating flush/surface mounting with copper busbar of suitable rating, with neutral bar and earth bar and cable tie for cable management, IP54 Protection and provision and including MCCB 4 pole upto 200 Amp,16KA as incomer and provision for MCBs as outgoing, dust and vermin proof complete as per IEC61439-3 complete all as specified and as directed. Note: MCBs for outgoing shall be measured and paid separately. |
| 242 | S & F blanking plate in DBs of MCB complete all as specified and as directed. |
| 243 | Supply and fix concealed sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 6 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 6 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note 1- Two runs of 6 sqmm cable, one run of 6 sqmm cable and one run of conduit shall be measured and paid as one unit length. Note 2- Cost of cutting chase and making good shall be included in the quoted rate.) |
| 244 | Supply and fix concealed sub main wiring complete with and including four Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 6 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 6 sqmm two Nos single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note 1- Four runs of 6 sqmm cable, two runs of 6 sqmm cable and one run of conduit shall be measured and paid as one unit length. Note 2- Cost of cutting chase and making good shall be included in the quoted rate.) |
| 245 | Supply and fix concealed sub main wiring complete with and including four Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 10 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 10 sqmm two Nos single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note 1- Four runs of 10 sqmm cable, two runs of 10 sqmm cable and one run of conduit shall be measured and paid as one unit length. Note 2- Cost of cutting chase and making good shall be included in the quoted rate.) |
| 246 | S & F including testing LED batten light fitting 1 X 20 watt, 04 Feet long, with aluminium housing and polycarbonate diffuser complete with integrated LED driver suitable for fixation on wall/roof with robust body, corrosion resistant, flicker control, superior finish. The power factor should be more than 0.95, total harmonic distortion (THD) should be less than 20%, lumen efficacy should not be less than 100 lumens per watt, total input voltage range 140-280V AC, colour rendering Index should not be less than 80, corelated colour temperature should 5000⁰-6500⁰ Kelvin, life span of minimum 50000 working hours including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 247 | S & F including testing LED batten light fitting 1 X 10 watt with aluminium housing and polycarbonate diffuser, 2 feet long complete with integrated LED driver suitable for fixation on wall/roof with robust body, corrosion resistant, flicker control, superior finish. The power factor should be more than 0.95, total harmonic distortion (THD) should be less than 20%, lumen efficacy should not be less than 100 lumens per watt, total input voltage range 140-280V AC, colour rendering Index should not be less than 80, corelated colour temperature should 5000⁰-6500⁰ Kelvin, life span of minimum 50000 working hours including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 248 | S & F LED bulb, System Wattage: 9 Watt, Rated Voltage: 230 Volt, Frequency: 50 Hertz, Operating Voltage Range: 170 to 270 Volt, System Current (mA): < 46, Power Factor: ≥ 0.98, System Lumen Efficacy (lumens/watt or lumens): 100, Total Harmonic Distortion (THD): ≤ 30 %, Color Rendering Index (CRI): ≥ 80, Driver Efficiency: ≥ 85 %, Ingress Protection: IP20, Correlated Color Temperature (CCT) (As per ANSI): 6500⁰ Kelvin, life span 50000 burning hours, Mounting/Holder Type/Base cap: B22d, System Protections: Open & Short circuit protection, reverse polarity protection, surge protection of 2.5KV internal, Certification Standards: LM80, Conformity to Indian Standard: IS:16102 part I and Part II latest complete all as specified and as directed. |
| 249 | S & F LED street light fitting of 35 W pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street/Roadway luminaire, with driver complete fitting with all accessories and following specifications including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and as directed.(a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range: 140 to 270 volts (c) Temp operating range: Minus 10°C to Plus 50°C (d) Power factor: Minimum 0.95 (e) THD: Max10%. (f) IP rating: Minimum IP66. (g) IK rating: Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz. open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 10 Kv (inbuilt + extended) (l) CCT: 5000 K. (m) CRI: More than 80 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time: 50000 burning hrs @L70 (Average 10 to 12 hrs daily) |
| 250 | Supply, fixing and testing LED batten with battery/Invertor, LED Rating (in Watts)/System Wattage/Rated Power: 20 Watt, Rated Voltage & Frequency: 230V, 50Hz, Luminaire System Efficacy (Lumen/watt): 100, Operating Voltage Range: 140-280V, Power Factor: ≥0.95, Total Harmonic Distortion: ≤30%, Colour Rendering Index(CRI): ≥80, Colour Temperature: 5000⁰-6500⁰ Kelvin, Driver Efficiency: ≥85%, Emergency Time: 3 hour, Ingress Protection: IP-20, Type of Control Gears: Electronic, Working life for LED (as per LM-80 and LM 21 reports): ≥50000 hours, Housing Material: Aluminium Extruded, Front Cover Material: Polycarbonate, Surge Protection of 3.0 kV Internal: Yes, Open & Short Circuit Protection: Yes, Reverse Polarity Protection: Yes, Battery Type: Li-Ion, Battery Backup (in Hours): 3, Emergency Light Output (Lumen %): 50, including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 251 | Supplying, installing, testing and commission of commercial kitchen stainless steel exhaust, chimney/ hood system having the following components: -(a) Commercial kitchen stainless steel hood (6 feet long/ 2.8 feet wide) of stainless steel 304 grade, double filter absorber type, rust free grade steel, inbuilt with automatic sensor as per OEM specifications.(b) Automatic mode changer (drift air), turbo force 5 HP motor with bird screen for protection against bird and foreign materials, rust free body and plates, automatic shutter function complete metal body(c) Double coated high grade ducting material 40 feet long, high quality material as per OEM specificationsNote: The contractor shall design the ducting portion as per the drawings and room capacity of kitchen portion of the drawings and calculate the requirement of ducting and submit the design to the GE for approval. The quoted rate shall be inclusive of all these aspects. |
| 252 | Supply, Fixing and testing High Bay Beam LED light fitting of 50 Watt specifically designed heat sink for long life vertical high bay /medium LED luminaries complete with body robust,corrosion resistant,superior finish and without any cracks or through holes,made in a single piece by high pressure die cast aluminium alloy including fixing on wall/roof with help of suitable GI clamps, nuts, bolts, pendant of suitable length and washers etc complete all as directed.The luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP -65 protection as per IS - 10322-1982(Part -I) with latest amendments and input voltage range 140 - 300 V, AC, frequency 50 - 60 Hz ,P.F should be more than 0.9 with Total Harmonic Distoration THD(I) less than 15% ,cool white colour and lamp starting time should not be more than 10 second. Fitting should be provided with 10 KV surge protection.Driver should be constant current constant voltage driver .Driver should have high voltage withstanding capacity upto 300 V, AC. Driver should also have double phase protection,no load , open circuit and short circuit protection .LED light fitting should be suitable for ambient temperature from -10 degree Centrigrade to 50 degree Centrigrade and humidity level 10% to 90 % RH complete all as specified |
| 253 | Supply and fixing round shape 15 watt, 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. |
| 254 | S & F TV Socket (01 Module Square Design) with metal flush box having hole for 20mm conduit entry for TV connection complete all as specified and directed by Engr-in-Charge. |
| 255 | S & F 3 Pin Telephone Socket RJ 11 with metal flush box having hole for 20mm conduit entry for telephone connection complete all as specified and directed by Engr-in-Charge. |
| 256 | S & F 15 mm nominal size, nonrising spindle type fancy angle stop valves, two ways in double control with wall flange, made of cast brass including knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed. |
| 257 | S & F 15 mm wash basin mixture, centre hole, mixing hot & cold water, fancy type, cast copper alloy, chromium plated with capstan head, chromium plated, screwed down high pressure, screwed for iron pipe etc and fixed in repairs complete all as specified and directed by engineer in charge. Make : Jaquar Cat No: 5001B or equivalent as approved by the GE. |
| 258 | S & F health faucet with jet spray, 1.5 metre long, cast copper alloy, nickel chromium plated finish, 15 mm bore, 100 mm long with 1.5 metre long stainless steel shower hose and mounting device attached to wall complete all as specified and as directed. |
| 259 | S & F factory made rubber coated cement concrete paver block 60 mm thick (M35 grade with minimum compressive strength of 35 N/mm2), manufactured using cement, graded coarse aggregate, , fine aggregates and synthetic rubber layer of 5mm thickness, of approved shape and size (typically 200 mm X 100 mm or equivalent) in approved colour with smooth antiskid finish having, water absorption not more than 6%, abrasion not more than 2% and high slip resistance and in accordance with the provision of IS 15658:2006, IS 10262: 2019, IS 456: 2000, IS 2308 (Pt-l to VIII) and IS 1199: 1959 and laid over 30 mm thick average sand bed , filling joints with fine sand, complete all as specified and directed. |
| 260 | S & F class SN 8 structured wall polyethylene piping system (pipe with online coupler and elastomeric rubber ring) with hollow annular profiled outer surface and a smooth inner surface (double wall corrugated) for non-pressure underground drainage and Sewerage application, Type B, Nominal Size (DN/ID) 150, made of polyethylene (PE) material conforming to per IS 16098 (Part 2):2013 and to be transported, handled, installed and jointed as per Annex A of IS 16098 (Part 2):2013 complete all as specified and as directed. |
| 261 | Supplying, installation, testing and commissioning of Outdoor unit Air Cooled VRV/VRF with hermetically sealed inverter type scroll Compressor works on R410A with heating & cooling both. The outdoor unit shall be a factory assembled unit housed in a sturdy weather proof casing constructed from rust-proofed mild steel panels coated with powder coated finish with noise level less than 62 dB, COP of system 3.7 at 100% load & 7.50 at 50% at AHRI conditions, with pre-coated heat exchanger, low noise condenser fan, auto check function for connection error etc, centralized controller for individual control complete as per OEM specifications of Capacity 8 HP ODU (Outdoor unit) complete all as specified and as directed.Note:- The manufacturer of ODU and compressor shall be same, Bidders has to submit the test certificates along with the delivery of VRF/VRV Units at site. All compressor shall have inverter technology i.e., outdoor units shall have all inverter-based compressor |
| 262 | Supplying, installation, testing and commissioning of Outdoor unit Air Cooled VRV/VRF with hermetically sealed inverter type scroll Compressor works on R410A with heating & cooling both. The outdoor unit shall be a factory assembled unit housed in a sturdy weather proof casing constructed from rust-proofed mild steel panels coated with powder coated finish with noise level less than 62 dB, COP of system 3.7 at 100% load & 7.50 at 50% at AHRI conditions, with pre-coated heat exchanger, low noise condenser fan, auto check function for connection error etc, centralized controller for individual control complete as per OEM specifications of Capacity 16 HP ODU (Outdoor unit) complete all as specified and as directed.Note:- The manufacturer of ODU and compressor shall be same, Bidders has to submit the test certificates along with the delivery of VRF/VRV Units at site. All compressor shall have inverter technology i.e., outdoor units shall have all inverter-based compressor |
| 263 | Supplying, installation, testing and commissioning of Outdoor unit Air Cooled VRV/VRF with hermetically sealed inverter type scroll Compressor works on R410A with heating & cooling both. The outdoor unit shall be a factory assembled unit housed in a sturdy weather proof casing constructed from rust-proofed mild steel panels coated with powder coated finish with noise level less than 62 dB, COP of system 3.7 at 100% load & 7.50 at 50% at AHRI conditions, with pre-coated heat exchanger, low noise condenser fan, auto check function for connection error etc, centralized controller for individual control complete as per OEM specifications of Capacity 40 HP ODU (20 HP+ 20 HP)(Outdoor unit) complete all as specified and as directed.Note:- The manufacturer of ODU and compressor shall be same, Bidders has to submit the test certificates along with the delivery of VRF/VRV Units at site. All compressor shall have inverter technology i.e., outdoor units shall have all inverter-based compressor |
| 264 | Supplying, installation, testing and commissioning of Outdoor unit Air Cooled VRV/VRF with hermetically sealed inverter type scroll Compressor works on R410A with heating & cooling both. The outdoor unit shall be a factory assembled unit housed in a sturdy weather proof casing constructed from rust-proofed mild steel panels coated with powder coated finish with noise level less than 62 dB, COP of system 3.7 at 100% load & 7.50 at 50% at AHRI conditions, with pre-coated heat exchanger, low noise condenser fan, auto check function for connection error etc, centralized controller for individual control complete as per OEM specifications of Capacity 48 HP ODU (16 HP X 3 Nos.)(Outdoor unit) complete all as specified and as directed.Note:- The manufacturer of ODU and compressor shall be same, Bidders has to submit the test certificates along with the delivery of VRF/VRV Units at site. All compressor shall have inverter technology i.e., outdoor units shall have all inverter-based compressor |
| 265 | Supplying, installation, testing and commissioning of indoor unit of 2 TR capacity 4 Way Cassette indoor unit of air conditioners, ceiling suspended high static unit complete with fan and fan motor, controls, drain Pump etc. complete all as specified and as directed.Note:- Bidders has to submit the test certificates VRF/VRV Units. |
| 266 | Supplying, installation, testing and commissioning of indoor unit of 1 TR capacity 1 Way Cassette indoor unit of air conditioners, high wall mounted unit complete with fan and fan motor, controls, drain Pump etc. complete all as specified and as directed.Note:- Bidders has to submit the test certificates VRF/VRV Units. |
| 267 | Supplying, installation, testing and commissioning of indoor unit of 1.5 TR capacity 1 Way Cassette indoor unit of air conditioners, high wall mounted unit complete with fan and fan motor, controls, drain Pump etc. complete all as specified and as directed.Note:- Bidders has to submit the test certificates VRF/VRV Units. |
| 268 | Supplying, installation, testing and commissioning of indoor unit of 2 TR capacity 1 Way Cassette indoor unit of air conditioners, high wall mounted unit complete with fan and fan motor, controls, drain Pump etc. complete all as specified and as directed.Note:- Bidders has to submit the test certificates VRF/VRV Units. |
| 269 | Supplying, Installation, Testing and commissioning of Imported fittings Y-joints of size as required at site etc as per specifications as required complete all as specified and as directed. |
| 270 | Supplying and Installation of Interconnecting Refrigerant copper Piping of 41.3 mm O.D (outer dia)(insulation : 19 mm) as required for the full functionality of the VRV/ VRF system etc. complete in all respects duly insulated with closed cell nitrile rubber as per specifications of the manufacturer complete all as specified and as directed. |
| 271 | Supplying and Installation of Interconnecting Refrigerant copper Piping of 34.9 mm O.D.(insulation : 19 mm) as required for the full functionality of the VRV/ VRF system etc. complete in all respects duly insulated with closed cell nitrile rubber as per specifications of the manufacturer complete all as specified and as directed. |
| 272 | Supplying and Installation of Interconnecting Refrigerant copper Piping of 31.8 mm O.D.(insulation : 19 mm) as required for the full functionality of the VRV/ VRF system etc. complete in all respects duly insulated with closed cell nitrile rubber as per specifications of the manufacturer complete all as specified and as directed. |
| 273 | Supplying and Installation of Interconnecting Refrigerant copper Piping of 28.6 mm O.D.(insulation : 19 mm) as required for the full functionality of the VRV/ VRF system etc. complete in all respects duly insulated with closed cell nitrile rubber as per specifications of the manufacturer complete all as specified and as directed. |
| 274 | Supplying and Installation of Interconnecting Refrigerant copper Piping of 25.4 mm O.D.(insulation : 19 mm) as required for the full functionality of the VRV/ VRF system etc. complete in all respects duly insulated with closed cell nitrile rubber as per specifications of the manufacturer complete all as specified and as directed. |
| 275 | Supplying and Installation of Interconnecting Refrigerant copper Piping of 22.2 mm O.D.(insulation : 13 mm) as required for the full functionality of the VRV/ VRF system etc. complete in all respects duly insulated with closed cell nitrile rubber as per specifications of the manufacturer complete all as specified and as directed. |
| 276 | Supplying and Installation of Interconnecting Refrigerant copper Piping of 19.1 mm O.D.(insulation : 13 mm) as required for the full functionality of the VRV/ VRF system etc. complete in all respects duly insulated with closed cell nitrile rubber as per specifications of the manufacturer complete all as specified and as directed. |
| 277 | Supplying and Installation of Interconnecting Refrigerant copper Piping of 15.9 mm O.D.(insulation : 13 mm) as required for the full functionality of the VRV/ VRF system etc. complete in all respects duly insulated with closed cell nitrile rubber as per specifications of the manufacturer complete all as specified and as directed. |
| 278 | Supplying and Installation of Interconnecting Refrigerant copper Piping of 12.7 mm O.D.(insulation : 13 mm) as required for the full functionality of the VRV/ VRF system etc. complete in all respects duly insulated with closed cell nitrile rubber as per specifications of the manufacturer complete all as specified and as directed. |
| 279 | Supplying and Installation of Interconnecting Refrigerant copper Piping of 9.5 mm O.D.(insulation : 13 mm) as required for the full functionality of the VRV/ VRF system etc. complete in all respects duly insulated with closed cell nitrile rubber as per specifications of the manufacturer complete all as specified and as directed. |
| 280 | Supplying and Installation of Interconnecting Refrigerant copper Piping of 6.3 mm O.D.(insulation : 13 mm) as required for the full functionality of the VRV/ VRF system etc. complete in all respects duly insulated with closed cell nitrile rubber as per specifications of the manufacturer complete all as specified and as directed. |
| 281 | Supplying, installation, testing and commissioning of 25 mm dia rigid PVC piping complete with elbow T-joint, socket duly supported as per specifications and insulated with 6mm thick closed cell nitrile rubber insulation complete all as specified and as directed. |
| 282 | Supplying, installation, testing and commissioning of 32 mm dia rigid PVC piping complete with elbow T-joint, socket duly supported as per specifications and insulated with 6mm thick closed cell nitrile rubber insulation complete all as specified and as directed. |
| 283 | Supplying and installation 150mm (wide) x 50mm(depth) x 1.6mm (thick) perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required complete all as specified and as directed. |
| 284 | Supplying and installation 300mm (wide) x 50mm(depth) x 1.6mm (thick) perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required complete all as specified and as directed. |
| 285 | Supply, installation, commissioning and testing of factory made cubical type LT panel Board of Suitable size (CPRI approved) out door type dust proof, vermin proof with IP 54 protection made out of CRCA sheet 3.15 mm thick synthetic enamel paint over a coat of red oxide primer, fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including locking arrangements including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with copper bus bar capacity 250 Amps 04 Nos Three Phase and neutral (TPN) (in Separate chamber), bus bar fixed on epoxy coated insulator and provision with 1100 volt grade heat shrinkable type sleeves and housed in independent chamber having access both from front and back side, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 40 x40 x5mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :- (i) Supply and fix 4 Pole MCCB 300 Amp, 50 Hz, 415 V with rupturing capacity, Thermal magnetic relay adjustable type 35 KA. – 01 Nos (Incoming)(ii) Supply and fix 4 Pole MCCB 100 Amp, 50 Hz, 415 V with rupturing capacity, Thermal magnetic relay adjustable type 25 KA. – 02 Nos (Outcoming)(ii) Supply and fix TPN MCB 63 Amp with rupturing capacity, Thermal magnetic relay adjustable type 25 KA. – 03 Nos (Outcoming)(iv) Supply and fix MCB 2 Pole (DP), 25 Amp, 10kA, B Curve rating suitable for 240 Volts (Outgoing). – 10 Nos(v) Digital Voltmeter with built in selector switch 0-500Volts -1No(vi) Digital Ammeter with built in selector switch 0-500 amps with suitable CTs -1No(vii) LED Indicated Lamp (R, Y, B) |
| 286 | Supply, installation, commissioning and testing of factory made cubical type LT panel Board of Suitable size (CPRI approved) out door type dust proof, vermin proof with IP 54 protection made out of CRCA sheet 3.15 mm thick synthetic enamel paint over a coat of red oxide primer, fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including locking arrangements including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with copper bus bar capacity 150 Amps 04 Nos Three Phase and neutral (TPN) (in Separate chamber), bus bar fixed on epoxy coated insulator and provision with 1100 volt grade heat shrinkable type sleeves and housed in independent chamber having access both from front and back side, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 40 x40 x5mm, legs shall be 750 mm long, 450 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 300 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :- (i) Supply and fix 4 Pole MCCB 200 Amp, 50 Hz, 415 V with rupturing capacity, Thermal magnetic relay adjustable type 35 KA. – 01 Nos (Incoming)(ii) Supply and fix TPN MCB 100 Amp with rupturing capacity, Thermal magnetic relay adjustable type 25 KA. – 03 Nos( Outcoming)(iii) Supply and fix MCB 2 Pole (DP) , 25 Amp, 16kA, B Curve rating suitable for 240 Volts (Out going ). – 15 Nos(iv) Digital Voltmeter with built in selector switch 0-500Volts -1No(v) Digital Ammeter with built in selector switch 0-500 amps with suitable CTs -1No(vii) LED Indicated Lamp (R,Y,B) |
| 287 | Supply and fixing MCB DP of 25 Amp,16 KA with enclosure complete all as specified and as directed. |
| 288 | Supply, laying and erection of Copper conductor cable 50 sqmm (3½ Core) Armoured XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the trench or pipe complete all as specified and as directed. |
| 289 | Supply, laying and erection of Copper conductor cable 25 sqmm (3½ Core) Armoured XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the trench or pipe complete all as specified and as directed. |
| 290 | Supply, laying and erection of Copper conductor cable 10 sqmm (3½ Core) Armoured XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the trench or pipe complete all as specified and as directed. |
| 291 | Supply, laying and erection of Copper conductor cable 6 sqmm (3½ Core) Armoured XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the trench or pipe complete all as specified and as directed. |
| 292 | Supply, laying and erection of Copper conductor cable 1.5 sqmm (3½ Core) Armoured XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the trench or pipe complete all as specified and as directed. |
| 293 | Supply and fixing control cum transmission wiring of 2 core x 1.5 sqmm copper in suitable PVC conduits between indoor and out door unit complete all as specified and as directed. |
| 294 | Supply, Installation, testing & Commissioning of 10KVA Off Grid Solar Photovoltaic Power Plant with MONO Crystalline technology solar modules including 20 Nos of Solar tubular batteries (lead Acid) of 150 AH 12 V, 10 KVA Solar String Inverter complete all as specified and as directed. |
| 295 | Supply, Installation, testing & Commissioning of 15KVA Off Grid Solar Photovoltaic Power Plant with MONO Crystalline technology solar modules including 20 Nos of Solar tubular batteries (lead Acid) of 150 AH 12 V, 15 KVA Solar String Inverter complete all as specified and as directed. |
| 296 | Supply, Installation, testing & Commissioning of 50KVA Off Grid Solar Photovoltaic Power Plant with MONO Crystalline technology solar modules including 30 Nos of Solar tubular batteries (lead Acid) of 150 AH 12 V, 50 KVA Solar String Inverter complete all as specified and as directed. |
| 297 | Notes for Solar Power Plants as above;-(a) Quoted Rates are inclusive of Module mounting structure of Galvanised Iron as per OEM recommendation, AC and DC power supply Switched (MCBs), AC and DC cables as per load requirement, three nos of earthing Copper plate earthing for each installation, MC contractor, Inverter and Battery stand made of GI, Lightning Arrester as per OEM recommendations, Fire Extinguisher (2 KG ABC Powder type) for each installation, Cable lugs, connectors and other hardware required for installation of the Solar power plant, Necessary civil work including PCC square box of size 300x300x300mm.(b) All necessary item required to make functional the Solar power plant are deemed to be included in the quoted rates; no extra payment shall be admissible on this account Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail