Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Taking out doors, windows and clerestory window shutters (steel or wood) of area 3 sq. metres and below including stacking within 50 metres lead complete all as specified and directed. |
| 2 | M&L for UPVC factory made, white colour louvered ventilators made of extruded profiles with figured/ frosted glass louvers; profiles of frames and sash will be mitred cut and fusion welded at all corners including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware, EPDM gasket, 1.2 ± 0.2mm thick galvanised steel profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners complete all as specified and directed by the Engineer-in-charge. |
| 3 | M&L for UPVC factory made, white colour casement/ sliding window Three track made of extruded profiles with wall thickness of 2.3mm (+-0.2mm). Window profile with hollow sections with multichamber. Frame (88mm x 52mm), Sliding sash (42mm x 57 mm) sliding mesh sash (42mm x 57 mm) Sliding inter Lock (one verticle length in each shutters 45.4 mm x 28 mm) Glazed bead (24.5 mm x 16 mm) will be mitered cut and fusion welded at all corners including railing of holes for fixing of hardwear, EPDM gasket, 1.2 ± 0.2mm thick galvanised steel frame (30mm x 18 mm) 2 nos, sliding sash (30 mm x 18 mm) sliding mesh sash (26 mm x 10 mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, necessary zinc alloyed (powder coated) hardware like handles etc., steel rollers system, stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40 mm and required accessories and glass pane inserts of 5.5mm thick select quality sheet glass, rubber beading for fixing glass complete all as specified and directed by the Engineer-in-charge.(A) Area not exceeding 2.00 sqm each |
| 4 | M & L for Providing Second class teak wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length complete all as specified and directed by the Engineer-in-charge.Note: Hold fast lugs or dash fastener shall be paid for separately. |
| 5 | Providing and fixing Second class teak wood 35 mm thick panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, complete all as specified and directed by the Engineer-in-charge.Note:- Butt hinges and necessary screws shall be paid separately. |
| 6 | Providing and fixing chromium plated brass butt hinges (light/ordinary type) : 125x70x4 mm with necessary chromium plated brass screws etc. complete all as specified and directed by the Engineer-in-charge. |
| 7 | Providing and fixing Brass tower bolt (barrel type) 250x10 mm with necessary screws etc. complete all as specified and directed by the Engineer-in-charge. |
| 8 | Providing and fixing Anodised Aluminium handles 125 mm with plate 175 x 32 mm complete all as specified and directed by the Engineer-in-charge. |
| 9 | Providing and fixing Anodised Aluminium sliding door bolt 250x16 mm complete all as specified and directed by the Engineer-in-charge. |
| 10 | Supply & Fixing in repairs zebra blinds for windows with all necessary fittings all complete as specified & directed by Engineer-in-Charge. Including Dismantling old Blinds. |
| 11 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete fixed to openings /wooden frames with rawl plugs screws etc complete all as specified and directed by the Engineer-in-charge. |
| 12 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new steel work complete all as specified and directed by the Engineer-in-charge. |
| 13 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm complete all as specified and directed by the Engineer-in-charge. |
| 14 | Providing and laying vitrified floor tiles in 600x600 mm size (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete all as specified and directed by the Engineer-in-charge. |
| 15 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joint with white cement & matching pigments etc. complete all as specified and directed by the Engineer-in-charge. Size of Tile 600x600 mm |
| 16 | Providing and laying Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily complete all as specified and directed by the Engineer-in-charge. |
| 17 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete all as specified and directed by the Engineer-in-charge. |
| 18 | Providing and fixing Granite stone slab colour black, Cherry / Ruby red Area of slab over 0.50 sqm 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels complete all as specified and directed by the Engineer-in-charge. |
| 19 | Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead complete all as specified and directed by the Engineer-in-charge. |
| 20 | Providing and laying Polished Granite stone slab colour of Black, Cherry/ Ruby Red or equivalent flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. |
| 21 | Demolishing brick work in cement mortar manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead complete all as specified and directed by the Engineer-in-charge. |
| 22 | Half brick masonry with non modular fly ash bricks of class designation 10, conforming to IS :12894, in super structure above plinth and upto floor V level. Cement mortar 1 : 4 (1 cement : 4 coarse sand) complete all as specified and directed by the Engineer-in-charge. |
| 23 | Brick work with F.P.S.(non modular) bricks common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) : complete all as specified and directed by the Engineer-in-charge. |
| 24 | M & L for 12 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand) complete all as specified and directed by the Engineer-in-charge. |
| 25 | M & L for Preparation of new surface of internal wall and applying 2mm thick Wall care putty including sand papering the puttied surfaces to form an even and smooth surface complete all as specified and directed by the Engineer-in-charge. |
| 26 | M & L applying two coats of plastic emulsion over a coat of interior primer complete all as specified and directed by the Engineer-in-charge. |
| 27 | Raking out joints in lime or cement mortar and preparing the surface for re-pointing or replastering, including disposal of rubbish to the dumping ground complete all as specified and directed by the Engineer-in-charge. |
| 28 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) complete all as specified and directed by the Engineer-in-charge. |
| 29 | M&L 75mm thick cement concrete (1:3:6) type C-2, using 40mm graded aggregate as in plinth protection including finishing the surfaces even and smooth without using extra cement complete all as specified and directed by the Engineer-in-charge. |
| 30 | M&L for filling the existing cracks on plastered surfaces of walls by using Dr. Fixit Crack-X Shrinkfree compound incl preparation of surfaces before application by opening the cracks and cleaning off the dust, dirt etc. for ease of application of paste all as per manufacturer's instructions and making good surfaces complete all as specified and directed by the Engineer-in-charge. |
| 31 | M&L for Chipping of unsound/ weak concrete material in patched for 15mm average thickness from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. complete with necessary scaffolding/ staging and disposal of debris for all lead and lifts complete all as specified and directed by the Engineer-in-charge. |
| 32 | M & L for Cleaning of reinforcement in pathes from rust from the reinforcing bars of dia upto 12mm to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, complete all as specified and directed by the Engineer-in-charge. |
| 33 | M & L for mixing and applying SBR polymer modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) 15 mm average thickness each in three layers of as per specifications and directions of Engineer-in-charge.Note: Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument complete all as specified and directed by the Engineer-in-charge. |
| 34 | Supply Water proofing compound. |
| 35 | Removing building materials etc other than soil to a distance 500m but n exc 1.0 Km beyond the lead including in rates, including loading, unloading ant stacking at destinations complete all as specified and directed by the Engineer-in-charge. |
| 36 | Providing and laying cement concrete 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing complete all as specified and directed by the Engineer-in-charge. |
| 37 | Steel reinforcement Thermo-Mechanically Treated bars of grade Fe-500D or more for R.C.C. work ready to use \\"cut and bend\\" rebars of approved make from factory/ workshop to construction site including placing in position and binding all complete upto plinth level complete all as specified and directed by the Engineer-in-charge. |
| 38 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per complete all as specified and directed by the Engineer-in-charge. |
| 39 | Dismantling 15 to 40 mm dia G.I. pipe including stacking of dismantled pipes (within 50 metres lead) complete all as specified and directed by the Engineer-in-charge.(a) Internal Work- Exposed on wall |
| 40 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete all as specified and directed by the Engineer-in-charge.a) 15 mm nominal dia Pipes |
| 41 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete all as specified and directed by the Engineer-in-charge. a) 20 mm nominal dia Pipes |
| 42 | S&F in repairs Bib taps, 15mm bore, cast copper alloy, chromium plated with crutch handle, short body with wall flange, screwed down, screwed for iron pipe or for brass ferrule all as specified and as directed. |
| 43 | S&F in repairs 15mm dia Pillar taps, cast copper alloy, with long neck, chromium plated fancy type with aerator, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed by the Engineer-in-charge. |
| 44 | S&F in repairs C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 of of 15 mm nominal bore including Taking Down complete all as specified and directed by the Engineer-in-charge. |
| 45 | S&F in repairs cast copper alloy, chromium plated 2 way bib cock 15mm dia with crutch handle with wall flange complete all as specified and directed by the Engineer-in-charge. |
| 46 | S&F in repairs Self-closing taps, cast copper alloy, chro-mium plated, screwed for iron pipe and fixed with connecting CP pipes complete all as specified and directed by the Engineer-in-charge. |
| 47 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. complete all as specified and directed by the Engineer-in-charge. |
| 48 | Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm length 15 mm nominal bore complete all as specified and directed by the Engineer-in-charge. |
| 49 | S&F Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank complete all as specified and directed by the Engineer-in-charge. |
| 50 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 20 mm nominal bore complete all as specified and directed by the Engineer-in-charge. |
| 51 | S&F nahani grating 100 mm dia complete all as specified and directed by the Engineer-in-charge. |
| 52 | Providing and fixing in repair Chlorinated Polyvinyl Chloride (CPVC) 100 mm nominal dia Pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete all as specified and directed by the Engineer-in-charge. |
| 53 | S&F in repair vitreous china white flat back wash hand basin 550 x 440mm size including 15mm dia PVC connection 600mm long, brass CP waste coupling, 32mm dia PVC waste pipe, CI/MS brackets including cutting for and pinning in brackets or fixed with brass screws complete all as specified and directed by the Engineer-in-charge. |
| 54 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid complete all as specified and directed by the Engineer-in-charge. |
| 55 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : Single half stall urinal with 5 litre P.V.C. automatic flushing cistern complete all as specified and directed by the Engineer-in-charge. |
| 56 | Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) and finished smooth. Granite Stone of approved shade complete all as specified and directed by the Engineer-in-charge. |
| 57 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete all as specified and directed by the Engineer-in-charge. |
| 58 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour . 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms complete all as specified and directed by the Engineer-in-charge. |
| 59 | S&F in repair brass chromium plated Soap dish complete all as specified and directed by the Engineer-in-charge. |
| 60 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :150 mm diameter complete all as specified and directed by the Engineer-in-charge. |
| 61 | M & L for complete removal of existing treatment from internal wall and applying 2mm thick Wall care putty including sand papering the puttied surfaces to form an even and smooth surface complete all as specified and directed by the Engineer-in-charge. |
| 62 | M & L for applying two coats of plastic emulsion over a coat of interior primer on new surfaces complete all as specified and directed by the Engineer-in-charge. |
| 63 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work complete all as specified and directed by the Engineer-in-charge. |
| 64 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: One or more coats on old work complete all as specified and directed by the Engineer-in-charge. |
| 65 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement complete all as specified and directed by the Engineer-in-charge.Note: for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc. |
| 66 | M&L for post construction anti-termite treatment at points of contact of wood work by chemical emulsion (water based solution) @ 0.5 Ltr/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same with chlorophyriphos or lindane emulsifiable concentrate conforming to IS 8944 or IS 632 respectively complete all as specified and directed by the Engineer-in-charge. |
| 67 | M<reatment of soil under existing floor using emulsion at 1 ltr per hole 300mm centre to centre including drilling and plugging 12mm dia holes with CM 1:2 to match existing floor complete all as specified and directed by the Engineer-in-charge. |
| 68 | M&L treatment along external wall below concrete or masonry /apron using chemical at 2.25 ltr per running metre including drilling and punching holes etc., in apron complete all as specified and directed by the Engineer-in-charge. |
| 69 | Taking down existing roof treatment of any description including roof plaster and removing the debris to a distance exc. 500m and depositing out side MD land complete all as specified and directed by the Engineer-in-charge. |
| 70 | Water proofing with PU membrane (a): - M& L for mechanical cleaning of surface to make it free from any bituminous residue /dirt, oil and Greece etc all as specified and directed by GE/Engr-in-Charge.(b) M&L for cracks treatment by cutting open cracks and cleaning it from dirt/loose materials etc and filling with polyurethane based sealant with and including application of PU based primer all as directed by GE/Engr-in-Charge . (c) M&L for applying water based polyurethane modified dispersion (single component, cold applied, non toxic, VOC complaint) in 03 coats including 01 coat of primer of same materials after dilution of water at 50% or specific primer matching same materials as per manufacturer specification and as directed by GE/Engr-in-Charge. |
| 71 | Properties of Polyurethane based chemical shall confirm to following Technical Parameters:-(i) Highly Elastic.(ii) UV Resistance.(iii) Adhesion to concrete.(iv) Tensile strength – not less than 2.0 N /Sq.mm for free film.(v) Elongation – not less than 300%.(vi) Solid content by weight- not less than 60%(vii) Air/water permeability BSEN 12390 at 5 bar -72 hours should be NIL and minimum dry film thickness of water proofing membrane must be 1.0 mm.(viii) Accelerated weathering (ASTM453) : Pass 1000 hours. (ix) Reaction to fire – non inflammable. |
| 72 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. |
| 73 | Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. |
| 74 | Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed byEngineer-in-Charge. Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection > 85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity <0.043 w/mK |
| 75 | M&L In repairs Toughned glass partition and doors of thickness 12mm with all fittngs complete including all as directed and specified. |
| 76 | Taking down copper/ aluminium point wiring (light, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safecustody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as speciifed and directed. |
| 77 | Taking down carefully ceiling fan/ wall mount fan of any make,size from its location, dismantling complete fan, examine complete parts throughly, oiling greasing all parts and complete overhauling of fan, inclusive replacement of parts such a bushes/ bearings and assembling complete fan and make fully functional and refixing/ hanging of ceiling fan by replacing the existing 1 feet length down rod with existing dia/ size of 1mtr length of GI pipe medium grade 15 mm along with new fixing clamps powder coated semi threaded Bolts and nuts with washers and safety pins, vibration damper bush complete all as speciifed and directed. |
| 78 | Taking down old DBs with MCCB , MCBs of any size and capacity & making good to the disturbed surface to match with the existing complete all as specified and directed by Engineer-in-Charge. |
| 79 | Taking down old sub main wiring/cable of any size and capacity including making good to the disturbed surface to match with the existing complete all as specified and directed by Engineer-in-Charge. |
| 80 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. Group-C complete all as specified and directed by Engineer-in-Charge. |
| 81 | Supplying and fixing 3 pin 5/6 A modular socket outlet complete all as specified and directed by Engineer-in-Charge. |
| 82 | Supplying and fixing modular switch one way 6 Amps on the existing modular plate & switch box including connections but excluding modular plate etc. complete all as specified and directed by Engineer-in-Charge. |
| 83 | Supplying and fixing 15/16 A modular socket outlet complete all as specified and directed by Engineer-in-Charge. |
| 84 | Supplying and fixing modular switch one way 15/16 Amps on the existing modular plate & switch box including connections but excluding modular plate etc. complete all as specified and directed by Engineer-in-Charge. |
| 85 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. complete all as specified and directed by Engineer-in-Charge. |
| 86 | Supplying and fixing two module stepped type electronic fan regulator to the existing modular plate switch box including connections but excluding modular plate etc. complete all as specified and directed by Engineer-in-Charge. |
| 87 | Supplying and fixing modular bell push on the existing modular plate & switch box including connections but excluding modular plate etc. complete all as specified and directed by Engineer-in-Charge. |
| 88 | Supply & fixing of call bell / buzzer complete all as specified and directed by Engineer-in-Charge. |
| 89 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required for light point, 5 Amps socket, 16 Amps power socket & sub main wiring complete all as specified and directed by Engineer-in-Charge.Note: All copper conductors including PVC conduit shall be measured as one unit. |
| 90 | (a) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire (5Amp Power sockets) |
| 91 | (b) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire (15A power Sockets + AC Sockets) |
| 92 | (c) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire (AC Circuit) |
| 93 | (d) 2 X 10 sq. mm + 1 X 6 sq. mm earth wire (Main Circuit) |
| 94 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engineer-in-Charge. |
| 95 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed by Engineer-in-Charge. |
| 96 | Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engineer-in-Charge. |
| 97 | S&F LED base street lumainare 35 W with pressure die cast aluminium housing with Poly carbonate coverand high power LEDs and secondary lenses with IP 66 Protection including 40 x 6mm flat iron clamps, nut, bolts, washer with 32 mm dia GI pipe light grade bracket bend to shape not less than 1.2 m long complete all as specified and directed by Engineer-in-Charge. |
| 98 | Supplying and fixing of 8 way (4 + 24), Double door surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) complete all as specified and directed by Engineer-in-Charge. Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required. |
| 99 | S & F in repair MCB DB double door SPN 8 Way with 200 Amps rated copper bus bar complete all as specified and directed by Engineer-in-Charge. |
| 100 | Supply and fixing SP 6 To 32 AMP, amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed by Engineer-in-Charge. |
| 101 | Supply and fixing SPN 32 AMP, amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed by Engineer-in-Charge. |
| 102 | Supply and fix MCB TPN 63 Amps 4 Pole, with breaking capacity 10 KA along with replacement of old unserviceable one complete all as specified and directed by Engineer-in-Charge. |
| 103 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. but with charcoal/ coke and salt complete all as specified and directed by Engineer-in-Charge. |
| 104 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing complete all as specified and directed by Engineer-in-Charge. |
| 105 | M& L for taking down the split AC indoor unit from false ceiling/wall carefully and making good to the disturbed surface to match with the existing,deposite in MES store yard and after completion work refixing the indoor units at their existing/new loaction complete electrical connection as per earlier make it operational including brazing work,insulation,required copper tube & gas charging if required complete all as specified and directed by Engr-in-charge. |
| 106 | Supply and fixing 20A, 240V, SPN industrial type socket outlet, with 2pole and earth, metal enclosed plug top alongwith 20A \\"C\\" curve, SP, MCB, in sheet encloser, on surface or in resess, with chained metal cover for the socket out let and complete with connections, testing and commissining etc. as required complete all as specified and directed by Engr-in-charge. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail