| 1 | Supply and fix in replacement of unserviceable one with new Cast Iron sluice valve IS 14846 -2000 PN1.6 both flanged heavy duty drilled and installed with brass spindle gun metal face rings rubber gasket 3mm thick MS bolts nuts and washers graphite rope complete including taking down of the old unserviceable valves for following bore :- |
| 2 | 150 mm bore |
| 3 | 100 mm bore |
| 4 | Dismantling the defective electric driven centrifugal pump set of capacity 100 HP from foundation by opening of coupling and foundation bolts and transporting to workshop for repairing and reassembling after servicing and overhauling complete with oiling/greasing, lubricating the parts including repair / replacement of worn out parts and spray painting with synthetic enamel paint of existing colour and writing SM / MES No with white synthetic enamel paint and installation commissioning and testing on full load complete all as specified and directed by Engineer-in-Charge. |
| 5 | Dismantling the defective electric driven centrifugal pump set of capacity 50 HP from foundation by opening of coupling and foundation bolts and transporting to workshop for repairing and reassembling after servicing and overhauling complete with oiling/greasing, lubricating the parts including repair / replacement of worn out parts and spray painting with synthetic enamel paint of existing colour and writing SM / MES No with white synthetic enamel paint and installation commissioning and testing on full load complete all as specified and directed by Engineer-in-Charge. |
| 6 | Dismantling the defective electric driven centrifugal jockey pump set of capacity 10-15HP from foundation by opening of coupling and foundation bolts and transporting to workshop for repairing and reassembling after servicing and overhauling complete with oiling/greasing, lubricating the parts including repair / replacement of worn out parts and spray painting with synthetic enamel paint of existing colour and writing SM / MES No with white paint and installation commissioning and testing on full load complete all as specified and directed by Engineer-in-Charge.Note for item Nos 2 & 4:- (i) The rate quoted for this item shall includes labour charge /maint repair and replacement of defective/unserviceable spares/accessories. (ii) Cost of other minor items/spares such as washers, gaskets, paints etc which are not covered under Sch 'A' but required for effective functioning of the plant shall be deemed to included in this item. (iii)Cost of spares, components such as impeller, ball bearing, motor coupling, bolts, nuts etc shall be measured and paid separately. (iv) Necessary gate pass shall be submitted along with RAR/FB duly signed by the concern. |
| 7 | Supply only spare parts of monoblock / centrifugal pumpsets complete all as specified and as directed. |
| 8 | CI impeller for Jockey pump |
| 9 | Ball bearing for Jockey pump |
| 10 | Motor coupling assembly with tyre for Jockey pump |
| 11 | CI impeller for centrifugal pump set |
| 12 | Ball bearing for centrifugal pump set |
| 13 | Motor coupling assembly with tyre for centrifugal pump set of capacity |
| 14 | Foundation bolts with nuts, washers etc |
| 15 | Material and labour for servicing Diesel Engine driven Fire fighting pump complete oil servicing, necessary replacement of below mentioned spares and servicing work for 112BHP fire fighting pump including 1 year warrantee for servicing .(a) Diesel Filter (Pre+micro) - 2Nos, (b) Engine Oil filter (Spain-on type) - 2 Nos, (c) Engine Oil as required, (d) Radiator Coolant - 1 Litres. |
| 16 | Material and labour for servicing Diesel Engine driven Fire pump complete oil servicing, necessary replacement of below mentioned spares and servicing work for 50BHP fire pump incl 1 year warrantee for servicing .(a) Diesel Filter (Pre+micro) - 2Nos, (b) Engine Oil filter (Spain-on type) - 2 Nos, (c) Engine Oil as required, (d) Radiator Coolant - 1 Litres. |
| 17 | Dismantling self starter of diesel engine driven fire pump of any make, opening up, overhauling / servicing including replacement of armature coils bushes carbon brushes, springs, screws, etc., assembling back, re-fixing and testing for diesel engine model 50-112BHP KVA capacity. |
| 18 | Removing the old unserviceable canvas hose pipe and taken as credit , supply, install, connect, test and commission new canvas hose pipe 63mm dia proof pressure of Kg.f/cm2 21.4, Burst pressure Kg.f/cm2- 35.7, fabric lined 15 meter long for housing in the fire boxes near hydrants as well as near landing valves |
| 19 | Removing the old unserviceable and taken as credit, Supply, installation, testing and commissioning of pressure gauges of range 20 Kg/cm2 for pumpset complete with ball valves for isolation, siphon, fittings complete all as specified and directed. |
| 20 | Removing the old unserviceable and taken as credit, Supply installing testing commissioning of double action pull push type manual call point glass break system, housed in MS enclosure with mounting accessories , complete in all respect and all as specified and directed. |
| 21 | Removing the old unserviceable nozzle and taken as credit , supply, install, connect, test and commission of branch pipe, short, GM with 63mm dia male instantaneous inlet and threaded outlet fitted with 15 mm bore nozzle confirming to IS-903 all as specified and directed. |
| 22 | Removing the old unserviceable gunmetal landing valves and taken as credit ,supply, install, connect, test and commission new Hydrants gunmetal landing valves double outlets 63mm dia female outlets. |
| 23 | Removing the old unserviceable rubber hose reel lined hose and taken as credit , supply, install, connect, test and commission new rubber hose reel lined hose 20mm dia fabric lined 30 meter long with 5mm outlet brass nozzle. |
| 24 | Replacement in repair of unserviceable fire hose cabinet box of size as per requirement of size 800x600x250 mm, made out from 16 gauge MS sheet duly painted with two coats of red colour synthetic enamel paint over a coat of red oxide primer with double leafed glazed shutters ( glazed with 4 mm thick glass ) suitable for housing of two length of canvas hose ,branch pipe, fire hose and nozzle, fireman axe, first aid hose and single outlet landing valve. |
| 25 | M & L for preparation of old painted surface of any description of 150mm dia pipe line of fire fighting installation including bends, flanges, valves, etc n. exc 10 cm in width or girth and applying one coat of heat resisting paint first quality of approved colour with colour code all as specified and directed. |
| 26 | Replacement in repair of unserviceable Sounder with strobe flame proof of 85 DB @ 3 M for audible automatic alarm annunciation and 75 cd flashing at 1 Hz for visual indication with control module. The sounder with strobe with control module shall be flush or surface mountable type with all accessories etc complete and as per technical specification UL listed and all as specified and directed. |
| 27 | Taking down unserviceable wiring and Supply, Laying, Testing, Commissioning of 1100 volts grade, 1.5 sqmm 2 core, FRLS, multistranded copper cable, armoured with steel strip/wire ISI marked including MS, ERW, Medium grade, 20mm, ISI Marked pipe for laying of cable fixed over the wall/roof, over the surface through saddles /spacers etc for making connections to fire detectors / MCP / SIREN / to control panels etc all as specified and directed. |
| 28 | Replacement in repair of unserviceable wiring and complete checking & repairing of automatic fire pump starting system including replacement of air vessel and pressure switches and control wiring complete from starter to pumps /control connections to control panels etc all as specified and directed. |
| 29 | Replacement in repair of unserviceable fire alarm panel and supply, Install, testing, commissioning of intelligent addressable fire alarm panel, 5 loop capacity expandable upto 10 loops, with minimum 250 address on every loop, minimum 640 characters LCD display, battery charger and power supply complete with all mounting accessories furnished with SMF type lead acid battery in above panel for 24 hours backup in case of power failure and 30 minutes in alarm condition. |
| 30 | Taking down fire alarm panel and complete check with system including all detectors check for fault in any height ceiling all as directed. |
| 31 | S&F in replacement of Addressable manual call point all as directed |
| 32 | S&F in replacement of Addressable multi sensor heat and smoke all as directed |
| 33 | S&F in replacement of 12x7 AH Battery all as directed |
| 34 | S&F in replacement of Responds indicator all as directed |
| 35 | S&F in replacement of Addressable Smoke detectors all as directed |
| 36 | S&F in replacement of flame detectors point all as directed |
| 37 | Lifting & reassembling of hangar doors leaf of size 15meter height & any size in width approximate weight of 6 Ton per leaf for repair and replacement of damaged parts dismantling of by providing necessary hydraulic jacks 3 ton capacity including provn of necessary scaffolding complete for repair/ replacement of unserviceable spares testing commissioning for smooth function of complete hangar door manually/ motorisedNote: All spare like bearing, wheels & shaft/ locking pins will be measured and paid separately contactor has to give on year guarantee for smooth operation of hangar doors as directed. |
| 38 | Supply & fix unserviceable top & bottom ball bearing of door leaf with new ball bearing fixed as per directed. |
| 39 | Supply & fix of hangar wheel heavy duty double flange steel track wheels of required dia as per sample to match with existed wheel including taking down as per direction of Engineer-in-charge. |
| 40 | M&L replacement of gear box cover made out of 1.6mm thick MS sheet with locking arrangement all as per existing six complete all as specified and as directed |
| 41 | Cleaning of iron top/bottom rail in hangar doors leaf slides on that cleaning with sand paper and oil suitable material side surface of rail and making free to move oiling/ greasing in top and side of rail complete of door as directed |
| 42 | Dismantling of motors of any make any capacity of 2/3/4/5 HP, Rewinding of motor completely including proper varnishing, and refixing of the same at existing site, connection testing & commissioning etc complete all as specified and as directed. |
| 43 | Material and labour for dismantling of unserviceable old gear box of hangar door and supply and fix new worm gear with coupling as per existing all as specified and directed. |
| 44 | Material and labour for dismantling of unserviceable floor mounted motor of hangar door and supply and fix in replacement of floor mounted motor of cap 01 to 03 HP 415 Volt all as specified and directed. |
| 45 | Material and labour for dismantling of unserviceable rotary limit switch and supply and fix new rotary limit switch all as specified and directed,. |
| 46 | M & L for dismantling of unserviceable burnt copper conductor cable and supply and fix in replacement of multicore copper conductor FRLS round cable size 1.5 sqmm 2 core all as specified and directed. |
| 47 | M & L for dismantling of unserviceable burnt copper conductor cable and supply and fix in replacement of multicore copper conductor FRLS round cable of size of 4 sqmm 4 core all as specified and directed. |
| 48 | Supply and fix in replacement of contactor with coil 32 Amp 4 pole suitable for existing door hangar complete all as specified and directed. Please Enable Macros to View BoQ information |