| 1 | Earth work in excavation by mechanical means (Hydraulicexcavator) / manual means in foundation trenches or drains(not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal ofsurplus excavated soil as directed, within a lead of 50 m.-All kinds of soil |
| 2 | Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete. |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering --All work upto plinth level: i) 4.1.7 1:4:8 ( 1 Cement: 4 fine sand : 8 graded well burnt brick aggregate 40 mm nominal size) |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering --All work upto plinth level: i) 4.1.7 1:5:10 ( 1 Cement: 5 fine sand : 10 graded stone aggregate 40 mm nominal size) |
| 5 | Providing and laying damp-proof course with cementconcrete 1:2:4 (1 cement: 2 coarse sand : 4 gradedstone aggregate 12.5mm nominal size). 4.10.1 D.P.C. 40 mm thick |
| 6 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement- -All work upto plinth level: 5.1.2 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 7 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding allcomplete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 8 | Centering shuttering including struttings, propping etc. and removal of form work for: 5.8.1.1 Foundations, footings, bases for columns etc. for mass concrete with timber plank |
| 9 | Centering shuttering including struttings, propping etc. and removal of form work for: 5.8.6.2 Columns, Pillars, Piers, Abutments, Posts and Struts with wooden plank |
| 10 | First class brick work in foundation and plinth including cost of all materials as required complete:-6.1.3 In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 11 | Half brick masonry work with first class bricks in superstructureup to floor level including cost of all materials as required complete:-6.10.3 In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 12 | Providing wood work in frames of doors,windows, clerestory windows and other frames, wrought framed and fixed in position : 8.1.3 Local Teak Wood |
| 13 | Providing and fixing ISI marked flush door shuttersconforming to IS: 2202 (Part I) decorative type, core ofblock board construction with frame of 1st class hardwood and well matched teak 3 ply veneering withvertical grains or cross bands and face veneers onboth faces of shutters.8.18.1 35 mm thick including ISI marked Stainless Steel butthinges with necessary screws. |
| 14 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square orround bars etc. all complete.8.46.2 Fixed to openings /wooden frames with rawl plugsscrews etc. |
| 15 | Providing 40 × 5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts,nuts and wooden plugs and embedding in cement concrete block 30 × 10 × 15 cm 1:3:6 mix (1 cement :3fine sand : 6 graded stone aggregate 20mm nominal size) |
| 16 | Providing and fixing aluminium sliding door bolts ISImarked anodised (anodic coating not less than gradeAC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :8.94.1 300x16 mm |
| 17 | Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 asper IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :8.98.1 125 mm |
| 18 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.9.12.3 Electric resistance or induction butt welded tubes. |
| 19 | Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing Tiron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete asper the direction of Engineer-in-Charge. |
| 20 | Steel work welded in built up section/framed work including cutting, hoisting, fixing in position andapplying a priming coat of approved steel primer using steel etc. complete as required:-9.15.2 In grating, frames, guard bar, railing, brackets, gates and similar works, all complete. |
| 21 | Providing and fixing M.S. round holding down bolts with nuts and wahser plates complete as per standard design. |
| 22 | Providing and fixing MS bolts including nuts and washers complete as per standard design:- 9.18.2 Above 300mm length. |
| 23 | Cement concrete flooring 1:2:4 (1 cement : 2 fine sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. all completeetc as per direction of Engineer-in-charge.10.5.1 40 mm thick with 20 mm nominal size stone aggregate |
| 24 | Providing and fixing glass strips in joints of terrazo / cement concrete floors all complete as per direction of Engineer-in-charge.10.20.1 40 mm wide and 4 mm thick. |
| 25 | Providing corrugated G.S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required etc. complete as per direction of Engineer-in-charge. 11.1.2 i).0.63mm thick with zinc coating not less than 275gm/m2. |
| 26 | Providing and fixing 15 cm wide 45 cm over all semi circular plain G.S. sheet gutter with iron brackets40x3mm size, bolts, nuts and washers etc. including making necessary connections with rain water pipes etc. complete as per direction of Engineer-in-charge11.7.2 0 .63mm thick with zinc coating not less than 275gm/m210.41.1.1 300 mm x 300 mm in all shades and designs |
| 27 | Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers etc. complete as per direction of Engineer-in charge.11.4.2 0 .63mm thick with zinc coating not less than 275gm/m2 |
| 28 | Providing and fixing plain Multipurpose Cement board(High Pressure steam cured) as per IS : 14862 : 2000 with suitable screws for fibre cement board in ceiling etc. complete as per direction of Engineer-incharge. (frame work to be paid separately) : 11.26.1 6 mm thick cement board |
| 29 | Providing wood work in frames of false ceiling, partitions etc. sawn and put up in position : 8.4.5 Soft Wood |
| 30 | 12 mm cement plaster of mix12.1.4 Cement mortar 1:6 (1 cement : 6 fine sand) |
| 31 | 15mm cement plaster on the rough side of single or half brick wall of mix:12.2.4 Cement mortar 1:6 (1 cement : 6 fine sand) |
| 32 | 12.10 Neat cement punning. |
| 33 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 grams/ litre, of approved brand and manufacture to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer] : 12.35.1 New work ( two or more coats) over and including water thinnable priming coat with cement primer. |
| 34 | Finishing walls with textured exterior paint of required shade of approved brand and manufacture [Payment shall be made after submission of Test Certificate issued by the Manufacturer] : 12.40.1 New work ( two or more coats applied @ 3.28 litre/10 sqm) over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm |
| 35 | Applying priming coat [Payment shall be made after submission of Test Certificate issued by the Manufacturer] :12.45.2 With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood. |
| 36 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer]: 12.60.1 Two or more coats on new work over an under coat of suitable shade with ordinary paint (primer) of approved brand and manufacture Please Enable Macros to View BoQ information |