| 1 | Excavation in foundation in ordinary soil including lead upto 30 meter and lift upto 1.5 meter and including of excavated earth in to the trenches or in to the sapce of the foundation trenches or into the plinth and removal and disposal of surplus earth as directed E/I (S.I. No. 251A) |
| 2 | Concrete with 4 cm. stone ballast fine sand nd cement in proportion of 12:6:1 in foundation and under floor and including supply of II material labour and T&P etc required for proper completion of the work. (S.I No. 281-275+273) |
| 3 | Class-150 brick work in 1:6 cement and Coarse sand mortar in foundation and plinth including supply of all materials, labour and T&P etc. required for proper completion of the work. (S.I. No.303+diff. +307-306) |
| 4 | 12mm Cement plaster with cement mortar in proportion of 1:4 cement & coarse sand of single coat for interior plastering upto floor two level including internal rounded angles chamfers, and rounded angles not exceeding 80mm. In girth and finished even and smooth. (S.I. No. 584a) |
| 5 | Cast cement concrete door sills, chaukhats, boundary posts shelves and similar small work with cement, approved coarse sand and 2 cm gauge stone grit in proporation of 1:2:4 excluding its fixing and binding the same with 24 B.W G.G.I, binding wire, moulds, all materials labour, T&P etc required, for proper complection of the work. The rate excludes making of drip course which shall be paid extra. S.I. No. 282 |
| 6 | RCC work Providing and laying in position specified grade of reinforced cement concrete , including the cost of centering, shuttering, finishing and excluding reinforcement - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) (S.I. No. 283) |
| 7 | R.C.C. work with cement, approved coarse sand and 2 cm gauge approved stone grit in proportions of 1:2:4 in raft foundation excluding supply of reinforcement and its bending, but including its fixing and binding wire and including necessary centering & shuttering etc. (S.I. No. 287) |
| 8 | R.C.C. work with cement, approved coarse sand and 2 cm gauge approved stone grit in proportions of 1:1.5:3 in column excluding supply of reinforcement and its bending, but including its fixing and binding wire and including necessary centering & shuttering etc. (S.I. No. 289) |
| 9 | R.C.C. work with cement, approved coarse sand and 2 cm gauge approved stone grit in proportions of 1:1.5:3 in slab excluding supply of reinforcement and its bending, but including its fixing and binding wire and including necessary centering & shuttering etc. (S.I. No. 284a) |
| 10 | P/L integral cement based water proofing treatment BIRCK KOBA including preparation of surface as required for treatment of roofs, consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS. 2645 including adjoining walls upto 300 mm height. (b) Laying brick bats with mortar with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 over 20 mm thick layer of cement mortar of mix 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 to required slope including rounding of junctions of walls and slabs (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement : 4 coarse sand) admixed with water proofing compound conforming to IS: 2645 including laying glass fiber cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final be flooded with water for a minimum period of two weeks for curing and for final test. With average thickness of 120 mm and minimum thickness at khurra as 65 mm. (Chapter 11 new item) |
| 11 | Mild Steel or TMT bars (Fe-500 D grade or higher) or HYSD Bars or Iron in plain work such as reinforced concrete or brick work (when not including in an over all rates) brought to required shaps as necessary including bending for proper complection of the work and including supply of all steel S.I. No. 504 |
| 12 | M.S. Or iron work in M.S grill and stair case railling including supply of all labour & material etc. required for complition of the work S.No 502 (A) |
| 13 | Mild steel and iron work of small size and section such as holding down Bolts, hold fasts, tierods, grating, etc. (When not included in and over all rates) brought to required form including supply of steel and its wastage including cost of bolts, nuts if required for proper completion of work including fabrication of holes in door chaukhats and nosing.Fabrication of Z-Section steel windows including necessary steel fitting such as handles stay etc. (S.I. No.502 B-I) |
| 14 | Supplying and fixing rolling shutters of approved make made of 8.25mm (3\\") x18 gauge cold rolled M.S. path interlocked through out their entire length and joined together at the end by end locks and mounted on specially designed pipe shaft with brick etc. side guides and arrangement for inside and out side locking with push and pull operation complete with excluding the cost of top cover and spring. (S.I. No.520 ) |
| 15 | Providing fixing 27.5 cm long wire spring grade two far rolling shutter S.I.No 521 |
| 16 | Providing and fixing Top cover for rolling shutter 2.5 mtr wide S.I.No 522 |
| 17 | Providing and fixing ball bearing rolling shutter S.I.No 523 |
| 18 | Earth filling in plinth including carted earth from distance 5 km. from the site of work including watering ramming and dressing etc. in 20cm. Layers required for proper completion of the work as per direction of E/I. S.I. No. 253A+Cartage. |
| 19 | Sand filling in plinth including supply of necessary quantity of sand including watering dressing etc. for proper completion of the work S.I No-255A. |
| 20 | M-150 Brick work in 1:6 Cement Coarse sand mortar in supper structure in one brick thick wall including supply of all material labour and T&P etc. required for proper completion of the work (S.I. No. 303 +Diff+ 307-306+309+310) |
| 21 | M-150 Brick work in 1:3 Cement Coarse sand mortar in supper structure in 1/2 brick thick wall including supply of all material labour and T&P etc. required for proper completion of the work (S.I. No. 307+ 309+310A) |
| 22 | 6mm Celling plaster 1:3 (1 cement : 3 fine sand) cement & fine sand in F.M. not less than 1.25, 1:3 including chiping of RCC surface before ceiling plaster. The cost of including all material, labour T&P and scafolding etc. complete. (Chapter_13_Item_13) |
| 23 | Providing wall putty with approved quailty materilas of berzer/J.K/ Birla or Similar make two coats S. No. Chap15 new item No. 03 |
| 24 | Distempering two coat oil bound distemper of approved brand and manufactured and required shade on undecorted wall surface to given an even shade over and including priming coat with cement primer off approved brand . Such as berger J&N, Asian paint after througly brushing the suface free from mortar dropping including the surface even plaster of paris and sand papered smoothly proper completion of the work. S.I. No 649+650 |
| 25 | Finishing wall with Weather Coat paint of approved make and qualilty on new work with two coat to give an even shade including supply of all materilas, labour and T&P etc requird for proper complection of the work S.I. No.new item |
| 26 | Painting or varnishing work in large areas or new wood work withone coat (upto one square metre) ready mixed priming paint and 2 coat of superior quality ready mixed paint or varnish including supply of all materials. Labour tools & plants etc required for proper completion of the work paint to be used should confirm the ISI no 644+645 |
| 27 | Providing fixing glass panes with teak wood beading in doors and windiws as desired by the E/I including cost of all materials fittings, hinges labour T&P etc required for proper completion of the work S.I. No 9.04 |
| 28 | 4cm thick plain cement concreet floor with 1:2:4 cement approved coarsand & stone grit laid in panels finished with 3 mm floating coat of neat cement and marble dust in ratio 5:1 as specified including supply of all material labour T&P required for proper complition of the work S.I. No. 605 |
| 29 | Providing and fixing glass strips of 5mm thick & 3.5 cm deep joints of floor at the time of laying labour T&P completed S.I.No. 631-d |
| 30 | providing and injecting chemical for preconstruction antitermite treatment and creating and chemical barrier under and arround the column pits wall trenches basement excavation top surface in plinth filling junction of wall and floor, along the extrnal perimetre of binding expansion joints surrounding or pipes and conduit etc. complete (plinth area of the building at ground floor only shall be measured as per I.S. 6313 (part II 1981) aldrine emulsifiable concentrate or any other approved matrial such heptachlor of chlordane will be used. the reae of application of chemical emulsion shall be as follow:- 1- Treatment for massonary and foundation 5 liters per sqm. 2- Back fill in immediate contact with foundation 7.5 liters per Sqm. 3- treatment of surface of plinth filling 5 liters per Sqm. 4- Treatment of soil alone external perameter of building 7.5 liters per sqm 5- Treatment of soil under external paremeter 5 liters per Sqm. |
| 31 | Plain cement concrect 1:2:4 C/sand 2 cm. Stone girt including supply all materials labour T&P etc S.I No. 279-A |
| 32 | Providing and laying of interlocking concrete block pavement having thickness 100 mm as per drawings and technical specification clause 1504. (Exclusive G.S.B) S.I. No. New item 15 |
| 33 | WBM Grading-3Providing & laying spreading and compacting stone aggregates of specifice size to water bound macadam specification including spreading in uniform thickness hand packing rolling with three wheel 80-100 Kn static roller in stages to proper grade and camber appling and brooming crushable screening to fill-up the interstice of coarse aggregate watering and compacting to the required density Grading 3 as per Technical specification Clause 405 Mord Book Page No. 4-18 |
| 34 | 2 cm thick plaster in dedo or skirting in 1:2 cement & C/sand including supply all materials labour T&P etc S.I No. 597. |
| 35 | Providing and fixing on wall face unplasticsed rigid PVC rain water pipes conforming to IS 13592 type A, including jointing with seal ring conforming to IS 5382 leaving 10 mm gap for thermal expansion . S.I. No. 730-A. |
| 36 | Finishing walls with weather Coat water proofing cement paint of approved make and quality on New work with two Coats give on even shade including supply of all materials labour T&P etc New Item No.8 +10 Chepter No.15 |
| 37 | M-150 Brick work in 1:4 cement & coarse sand in foundation and plinth including supply of all materials labour tools & plants etc. required for completion of the work. (S.I. No. 305a) |
| 38 | S/F of R.S.J size 200x100 mm wt. per Rm 25.40 kg fixing in position as per side including wastage cartage supply of completion of the work. Chepter No.10 New Item No.5 |
| 39 | Supply and fabrication of tubler trusses carting at site of work and fixing the same over RSJ including drilling holes and fixing including supply of all bolt and nuts westage labour T&P required for completion of the work. S.I. No. 10.16.1 |
| 40 | Supply and fixing precoated galvanised iron profile (size shap and pitch of corrugation as approved by E.I) 0.50 mm (+ 0.05%) total coated thickness with zinc coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 MPa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns, sheet sholud have protective guard film of 25 microns minimum to avoid scratches during tranportation and should be supplied in single length upto 12 metre or as desired by E/I. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required D.S.R 12.50 |
| 41 | S/F AC ridge with J or U bolt hooks and bitumen washer complete including supply of all materials Labour T&P etc.- S.I. No. 542 |
| 42 | M.S or iron work of small sizes and section as holding down bolts, hold fast tie rods grating etc wrought to required from including supply of steel bolts nuts eastage etc and their fixing required for proper complection of the work. S.I. No. 502 |
| 43 | Painting or varnishing work in small areas or new wood work withone coat (upto one square metre) ready mixed priming paint and 2 coat of superior quality ready mixed paint or varnish including supply of all materials. Labour tools & plants etc required for proper completion of the work paint to be used should confirm the ISI no103-1950 S.I. No. 641+642 Please Enable Macros to View BoQ information |