Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 02-04-2026 | Date Corrigendum | Date | 06-04-2026 |
| 2 | 01-04-2026 | Technical Corrigendum | Technical Bid | 06-04-2026 |
| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil. |
| 2 | Excavating trenches by mechinical / manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m: All kinds of soil Pipes, cables etc, not exceeding 80 mm dia. |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-Ill) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand (zone-Ill) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 5 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4(1 cement :4 coarse sand) |
| 6 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4(1 cement :4 coarse sand) |
| 7 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in : cement mortar 1:4(1 cement :4 coarse sand) |
| 8 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4(1 cement :4 coarse sand) |
| 9 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. Granite stone slab of colour black, Cherry/Ruby red Area of slab upto 0.50 sqnn |
| 10 | Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement: 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : Red sand stone - exposed face fine dressed with rough backing. 30 mm thick |
| 11 | Providing and fixing plywood 4 mm thick, one side decorative veneer conforming to IS: 1328 (type-1), for plain lining / cladding with necessary screws, including priming coat on unexposed surface with: Decorative veneer facings of approved manufacture |
| 12 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3(1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 13 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Second class teak wood |
| 14 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. Second class teak wood 35 mm thick |
| 15 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 16 | Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete: 2nd class teak wood 50x12 mm |
| 17 | Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete: 2nd class teak wood 50 x 20 mm |
| 18 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. |
| 19 | Providing and fixing hard drawn steel wire fabric 75x25 mm mesh of weight not less than 7.75 Kg per sqm to window frames etc. including 62x19 mm beading of second class teak wood and priming coat with approved steel primer all complete. |
| 20 | Providing 40x5 mm flat iron hold fast 400 mm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 300x100x150 mm 1:3:6 mix (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 21 | Providing and fixing plain lining with necessary screws/nuts & bolts/ nails, including a coat of approved primer on one face, and fixed on wooden /steel frame work, complete as per direction of Engineer-in- charge (Frame work shall be paid for separately). 12 mm thick commercial ply conforming to IS : 1328 BWR type |
| 22 | Providing and fixing frame work for partitions/ wall lining etc. made of 50x50x1.6 mm hollow MS tube, placed along the walls, ceiling and floor in a grid pattern with spacing @ 60 cm centre to centre both ways (vertically & horizontally) or at required spacing near opening, with necessary welding at junctions and fixing the frame to wall/ ceiling/ floors with steel dash fasteners of 8 mm dia, 75 mm long bolt, including making provision for opening for doors, windows, electrical conduits, switch boards etc., including providing with two coats of approved steel primer etc. complete, all as per direction of Engineer-in-charge. |
| 23 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 24 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 25 | Providing and fixing 1 mm thick M.S. sheet sliding-shutters, with frame and diagonal braces of 40x40x6 mm angle iron, 3 mm M.S. gusset plates at the junctions and corners, 25 mm dia pulley, 40x40x6 mm angle and 1- iron guide at the top and bottom respectively, including applying a priming coat of approved steel primer |
| 26 | Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 27 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes |
| 28 | Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. 10 x 160 mm |
| 29 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, bufing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 30 | Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides |
| 31 | Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. |
| 32 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick |
| 33 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 34 | 40 mm thick fine dressed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand), including pointing with cement mortar 1:2 (1 cement : 2 stone dust) with an admixture of pigment to match the shade of stone. Red sand stone |
| 35 | Providing and laying Vitrified tiles in floor in diferent sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Double charge vitrified tile polished finish of size Size of Tile 600 x 1200 mm |
| 36 | Providing and laying Vitrified tiles in floor in diferent sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm |
| 37 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab of all colour and texture except Black, Cherry/Ruby Red |
| 38 | Providing gola 75x75 mm in cement concrete 1:2:4(1 cement :2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement: 3 fine sand) as per standard design :In 75x75 mm deep chase |
| 39 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 40 | Providing and fixing M.S. holder bat clamps of approved design to C.I. or S.C.I. rain water pipes embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the walls etc. : 100 mm diameter |
| 41 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter |
| 42 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS :5382, leaving 10 mm gap for thermal expansion. Bend 87.5° 110 mm bend |
| 43 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS :5382, leaving 10 mm gap for thermal expansion. Shoe (Plain) 110 mm Shoe |
| 44 | Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05 mm) with Zinc coating 120 gram per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500- 600mm) |
| 45 | Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main 'T' runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross \\"T\\" of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main'T' at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross 'T' of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main 'T' runners to be suspended from ceiling using al. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main 'T'. Bottom exposed with 24 mm of all T-sections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection >85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity <0.043 w/mK. |
| 46 | Providing and fixing GI Clip in Metal Ceiling System of 600x600 mm module which includes providing and fixing 'C wall angle of size 20x30x20 mm made of 0.5 mm thick pre painted steel along the perimeter of the room with help of nylon sleeves and wooden screws at 300 mm center to centre, suspending the main C carrier of size 10x38x10 mm made of G.I steel 0.7 mm thick from the sofit with the help of sofit cleat 37x27x25x1.6 mm, rawl plugs of size 38x12 mm and C carrier suspension clip and main carrier bracket at 1000 mm c/c. Inverted triangle shaped Spring Tee having height of 24 mm and width of 34 mm made of GI steel 0.45 mm thick is then fixed to the main C carrier and in direction perpendicular to it at 600 mm centers with the help of suspension brackets. Wherever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/sqm (both side inclusive), fixing with clip in tiles into spring T with : GI Metal Ceiling Clip in plain Beveled edge global white color tiles of size 600x600 and 0.5 mm thick with 25 mm height, made of G I sheet having galvanizing of 100 gms/ sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted afer bending. |
| 47 | Providing and fixing multi walled transparent /opaque 10 mm thick polycarbonate sheet of required colour blue, brown or green etc. UV co-extruded and having UV coating on one side multi walled sheet of weight not less than 1.60 to 2.05kg/sqm as approved by Engineer-in-charge. The light transmission from transparent or translucent or opaque polycarbonate sheet varies from 30 to 80% and shall be decided by engineer in charge as per requirement. The panel shall satisfy the Dart drop impact test for value above 15 and upto 60 Joules and confirm either fame retardancy of class UL-94HB/94V-0 category as per ISI4434:2023 or category VO & HB as per ASTM D635-I8 or BSI DO classification as per EN13501 for fire safety. The yellowness index tested as per ASTM E313 (DI925) shall be less than or equal to 2 or it shall be I units as per ASTM D 2244 at the time of installation and shall be less than or equal to 10 as per ASTM E313 (1) 1925) or 6 units as per ASTM D 2244 on a sample after 5000 Hours of exposure of UV / sun light. The multi walled poly carbonate sheet shall he fixed on tubular steel structure with aluminium Alcox section of size 60x18x2 mm (anodized 25 micron thick) and weight not less than 0.462 kg/metre. Weather proof Neoprene/ EPDM rubber gasket shall be fixed on both side of joints to make the whole structure water tight as per approved design/drawings. The aluminium section shall be fxed on Joints at both sides (top & bottom) of polycarbonate sheet to hold the sheets rigidly together. The weather proof neoprene gasket and aluminium profile shall be fixed and sealed with silicon sealant to make the Joints fully water proof. The open overhead ends of polycarbonate sheet to be sealed with anodised aluminium U Profile/ channel of size 10x10x 1.5 mm thick of weight not less than 0.2kg/m. The polycarbonate sheet and aluminium profile shall be fixed to MS Framed Structure with self-taping and self-drilling 55mm long steel screws to be fixed @ 300mm centre to centre. The rate shall be inclusive of cost of all material involved such as polycarbonate sheet, aluminium profile and aluminium channel, EPDM gasket, Self-taping screws, nut bolts, Silicon sealant or any other material required for fixing the sheet but excluding the cost of steel structure which shall be paid separately including hoisting the sheets and fixing in position in required scaffolding shape. The rate shall also include the cost of all T & P scafolding and safety precautions required during execution of the work. The entire work shall be executed 10 mm thick and U- value not more than 2.50 W/m2K |
| 48 | 12 mm cement plaster of mix: 1:4(1 cement: 4 coarse sand) |
| 49 | Painting (two or more coats) on rain water, soil waste and vent pipes and fittings with black anticorrosive bitumastic paint of approved brand and manufacture, over and including a priming of ready mixed zinc chromate yellow primer on new work: 100 mm diameter pipes |
| 50 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 51 | Melamine polishing on wood work (one or more coat). |
| 52 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos. 2. Applying two coats of sealer with spray gun and allowing suficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs. 4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. using melamine clear polish and melamine thinner mixed in required. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) |
| 53 | Cutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia PVC pipe conforming BIS-12818 and making good the same etc. complete as per direction of Engineer-in- charge. |
| 54 | Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 3 mm thick |
| 55 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (including equivalent design mix) |
| 56 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:4:8 or leaner mix (including equivalent design mix) |
| 57 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar |
| 58 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area 3 sq. metres and below |
| 59 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. |
| 60 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm |
| 61 | Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. |
| 62 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 63 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer- in-charge. |
| 64 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 65 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap |
| 66 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink without drain board 610x460 mm bowl depth 200 mm |
| 67 | Supplying and fixing C.I. cover without frame for manholes : 455x610 mm rectangular C.I. cover (light duty) the weight of the cover to be not less than 23 kg |
| 68 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side |
| 69 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 70 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). |
| 71 | Grading roof for water proofing treatment with Cement mortar 1:4 (1cement : 4 coarse sand) |
| 72 | Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, upto 25 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40 mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge. Note:- (1) The elevational area of the scaffolding shall be measured for payment purpose. (2) The payment will be made once only for execution of all items for such works. |
| 73 | Cleaning the sand stone surface and removing dirt, dust, bird dropping, grease, oil, algae, fungus, monkey beats, vegetable growth etc., including providing, applying and washing the surface with liquid Ammonia Chemical of 5% solution and other chemical cleaning agent as approved by Archaeological Survey of India/ Engineer-in-charge, of approved brand and manufacturer, with the help of required scrubbers and also cleaning with machine operated water jet mixed with desired quantity of fine silica where ever required, without causing any scratching/ damage to the stone surface and finally washing the surface with clean water with the help of pressure jet machine, complete in all respect, including taking all precautions to safeguard ventilators, windows, doors etc. by suitable covering so as to avoid any damage to the building/structure, all as per direction of Engineer-in-charge (The rate is inclusive of all materials & labours involved except scaffolding). |
| 74 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5 mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. Frame size 50 x 100 mm |
| 75 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) 30 mm thick |
| 76 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :(Rates are excluding the material cost which will be provided by the department ) Two or more coats on new work (Material will be provided by the department free of cost) |
| 77 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.( (Rates are excluding the material cost which will be provided by the department ) (Material will be provided by the department free of cost) |
| 78 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.(Rates are excluding the material cost which will be provided by the department ) Two coats |
| 79 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. (Rates are excluding the material cost which will be provided by the department ) . With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre (Material will be provided by the department free of cost) |
| 80 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade( Rates are excluding the material cost which will be provided by the department ) Old work (Two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface (Material will be provided by the department free of cost) |
| 81 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade( Rates are excluding the material cost which will be provided by the department ) Old work (one or more coats applied @ 0.83 ltr/10 sqm). (Material will be provided by the department free of cost) |
| 82 | Modified Estimate Cost after correction on DSR items on a/c of GST@ 0.973 i.e. deduct for effect of correction factor on Item No. 1 to 3 (1-0.973)=0.027 |
| 83 | Add cost Index @ 3% |
| 84 | Providing and fixing Single Lever Tall Boy Basin Mixture (KUP-35005BPM) of Parryware/ Jaquar / Hindware or equivalent as directed by engineer in charge. |
| 85 | Providing and fixing C.P. brass towel rail 600 mm long with brackets fixed to wooden clats / rawl plugs with CP brass screws of approved make etc. complete as per direction of Engineer-in-Charge. Make Jaquar Cat.-AQN-7711 or equivalent in cost & specification. |
| 86 | Providing and fixing C.P. brass Hand shower (Health Faucet) having flexible tube of required length and wall hook of approved make etc. all complete as per direction of Engineer-in-charge. (Make Jaquar Cat-ALD-573 or equivalent in cost & specifications |
| 87 | Providing and fixing plain multipurpose cement board(Hight pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete (frame work to be paid seperatately). 6 mm thick Cement fiber board, Type-B, Category-III as per IS: 14862 : 2000 |
| 88 | Providing and fixing HDF wooden laminated Herringbone flooring 8mm thick of AC-4 HDF grade with density 900kg/M3 of \\"Action Tesa\\" or equivalent brand with plank size 99mmx600mm,texture DD along with 0.20 mm thick Polyurethane Sheet and 2mm thick PU foam as per approved colour, shade and design complete as per direction of Engineer-in-Charge. |
| 89 | Providing and fixing floor mounted, white vitreous china single piece suit S- traps water closet of Parryware/Jaquar (FSS-WHT-29853S300UFSM) shape, size 370x665x770 mm and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with UF slim seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. |
| 90 | Providing and fixing hard drawn steel wire fabric 75x25 mm mesh of weight not less than 7.75 Kg per sqm to window frames etc. including Flat 32x5 mm and priming coat with approved steel primer all complete. As per direction of Engineer-in-Charge |
| 91 | Providing and fixing C.P. brass bib cock with CP brass wall flange of approved make etc. all complete as per direction of Engineer-in-charge. 15 mm nominal bore. (Make Jaquar (code-OPPCHR-15037PM) or equivalent in cost & specifications. |
| 92 | Providing and laying broken glazed tiles not less than 9.00 kg./sqm on top of hot bitumen @ 1.7 kg/sqm (1.40 kg/sqm of 85/25 grade and 0.30 kg/sqm of 80/100 grade) and joints filled with cement mortar 1:2 (1 cement : 2 coarse sand) mixed with water proofing compound all complete as per the direction of the Engineer-in-Charge. |
| 93 | Providing and installing prefabricated sandwich PUF panel comprising of on two faces PPGL (galvalume ) colour coated 0.5mm TCT sheet and CFC free close cell high density figid polyurethane foam of high density (40+_2kg/m3 ) having a thermal conductivity value of 0.023 w/mk and of reuired thickness sandwich between the two galvalume sheet .the outer & inner galvalume sheet of 0.50mm TCT steel 550 Mpa shall have a coating mass of 150 g/sqm zinc aluminum alloy coating total of both sides as per AS1397 and finished with 20 microns colour coating of SMP polyster quality paint as per AS/NZS-2728:1997 (category=3) over a 5 micron primer on exposed side and a back coat of 5 microns on inner side over a 5 micron primer . the panels should be required length and required width with maximum width upto 1190mm with tongue & groove configuration the prefabricated panels shall be ficced dirctly to the girth using self drilling fasteners the metal sheet shall confirm to IS 513.AS1397&2728. The polyurethane insulation shall confirm to IS 12436. The rate of the item is inclusive of all materials erectionaccessories incidental charges coast of dash fasteners etc cost of making provision for door windows, ventilators and concealed pipe conduits and support for electrial and sanitary appliance etc and other incidental charges as per sample for payment finished puf sand witch panels shall be measured upto half centimetres for claculating area upto two places of decimal no deduction shall be made for opening upto 0.20sqm and no extra payment shall be made for wastages for roof panels 50(50/80) mm thick roofing panels having finished with 0.50mm thick TCT galvalume hi-rib sheet on outer side and 0.50mm TCT plain galvalume sheet on inner side including miscellaneous expenses of fixing accessories such as dash fasteners and making arrangement for concealed conduits etc. |
| 94 | Rubbing and polishing the terezo flooring, skirting and similar location which is already laid to give clear and bright surface as per direction of Engineer-in-charge |
| 95 | Providing and fixing in wall paneling in single layer exterior grade 18 mm thick HDHMR board of approved Action Tesa/Green ply or equivalent brand recommended grading treated for fungal/borer/termite resistance and calibratedfor high moisture resistance as per grade 1 IS12406-2003and also ecomarked labbeled by isi for environment friendly with density 850/kgcum(5% variation) to existing frame /basewall(which shall be paid seperatly) , with suitable full threaded steel screws etc. . all complete as per direction of Engineer-in-charge (Note: Fittings to be paid separately). |
| 96 | Providing and fixing 12 mm thick HDHMR-Plain board moistureresistance type,linned with necessary screws/nuts and bolts/nails and fixed on aluminiumMS tube frame work ( frame work will be paid separtely) all complete as per direction of engineer-in-charge. |
| 97 | Providing and fixing urinal( back inlet)with fixing accessories of size 385x 325 x 635 mm jaquar make (code-URS-WHT-13253N)or equivalent and having urinal valve autoclosing system with build-in control cock and wall flange of jaquar make (code-PRS-CHR-077) or equivalent including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. |
| 98 | Providing and fixing C.P. brass angular stop cock / angle valve with wall flange of approved make etc. complete as per direction of Engineer-in-Charge. 15 mm nominal bore. (Make Jaquar (code-KUP-CHR-35053PM) or equivalent in cost & specifications. |
| 99 | Providing and fixing C.P. brass bottle trap, 32mm nominal bore of approved make etc. all complete as per direction of Engineer-in-charge. Make Jaquar Cat.-ALD-769L300x190 or equivalent in cost & specifications |
| 100 | Providing and fixing C.P. brass soap dispensor with CP brass flange of approved make including fixing with PVC rawl plugs & screws etc. all complete as per direction of Engineer-in-charge. (Make Jaquar (Cat.-AKP-CHR-35735P) or equivalent in cost & specifications. |
| 101 | Providing and fixing Jaquar make Pillar Cock (Code- CON-CHR-011KN) or equivalentin Wash basin,all complete as per directions of Engineer-in-charge |
| 102 | Providing and fixing Jaquar make C.P. brass Long Body Bib cock (code - CON-CHR-107KN) or equivalent complete as per the direction of Engineer-in-charge. |
| 103 | Providing and fixing C.P. brass toilet paper roll holder with flap with CP brass flange of approved make including fixing with PVC rawl plugs & screws etc. complete as per direction of Engineer-in-Charge. Make of Jaquar Cat.-AQN-7753 or equivalent in cost & specifications. |
| 104 | Providing and Fixing 32mm CP waste coupling of 130mm height for wash basin, Urinal of Jaquar make Code -ALD-CHR -727 or qquivalent in cost & specification as per approved sample shape all complete as per direction of engineer-in-charge. |
| 105 | Providing and fixing table top wash basin(530x420x140mm) with pop up waste of standard pattern, cutting and making good the walls wherever required, complete as per direction of Engineer-in-charge.(a) Rectangle shape of make jaquar ( cat.no- JDS-WHT-25907N or equivalent in cost & specifications. |
| 106 | Replcament of approved quality (Top tech or equivalent) automatic flush system for uirnal spare parts complete as perdirection of Engineer-in-charge. Sensing system |
| 107 | Replcament of approved quality (Top tech or equivalent) automatic flush system for uirnal spare parts complete as perdirection of Engineer-in-charge. Solenoid valve |
| 108 | Credit for Dismantled Wooden materials |
| 109 | Credit for Dismantled C.P Fittings |
| 110 | Credit for Dismantled M.S./Reinforement bar materials |
| 111 | Credit for Dismental Aluminum Material Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail