| Sl. No. | Item Description |
| 1 | Engaging of 1 No 'C' Licence Holder (Supervisor) of day to day maintenance of Electrical maintenance works and to monitor these works are properly attended and to take care of complaints arised related to repairs / replacement of damaged fittings / fixtures in the campus such as switches, sockets, switch boards, HT/LT Panels , MCBs, MCB DBs, MCCBs, SFUs, FSUs etc., and all types of fans / light fittings, UG cables etc., complete all as directed by the Engineer-in-charge. ( 01 No.) (Qualification: Diploma in Electrical Engineering with 10 years related experience/ITI with 12 years or experience (supervisory) in maintenance job) (Qualification: ITI certificate with 03 years experience in operation of 11KV / 415V Substation and equipment and DG Sets along with valid 11KV /415V Supervisor permit /C- certificate/grade C-License Holder) (Higly Skilled). He is resposonsible to maintain & update the all logbook of preventive maintenace E&M equipment(Lifts,panels,Substation,DG sets,Fire equipment,RO,STP&ETP etc...) with respective staff.[1 No 'C' Licence Holder ( Highly Skilled)]. Note:- 1.He is the responsible for maintain the day to day complaint Register, Preperation of Duty Roster, Material Consumption Register, Log Book/Log sheets and to up keep the neat & Tidy of installations with installed plants & machinaries as per the direction of Engineer-in-Charge 2. He is the responsible for HT Metering cubicle to monitor & maintain all parameter readings.3. He is the responsible for timely calibration of HT VCB's, LT ACB's/MCCBs and Earth Fault Relays and Over Current Relays.4. He is the responsible for HT Panels, Transformers, ACBs, MCCBs, APFC Panels with connected Capacitor Banks, Power Contactors & Relays, Up Keep & maintain records for earth results in the HT & LT installations as per the direction of Engr-in-Charge.5. During Main EB supply failure to monitor the running of stand by DG Sets and maintain the Plant Running Record Book with all parameters.6. To maintain the EB Shutdown Register & obtain the necessary signature from EB authorities . (It should be talley with Stand By DG Set PRRB) |
| 2 | Engaging an Substaion attendant Cum DG Operator cum Panel opearator for day to day operation of Substation, DG sets, LT Panels , MCBs, MCB DBs, MCCBs, SFUs FSUs etc and all types of fans/ light fittings, UG cables etc complete all as directed by the Engineer-in-charge. and also Preventive maintenance of above mentioned equipment as per standerd check list and maintain logbooks along with shift register to be updated daily etc to be maintained as directed by engineer-incharge.. Skilled (ITI Certificate with 3 Years Experience)Note: 1. During Gen Shift, DG Opr cum Panel Board Operator can do the Electrical day to day complaints/maintenance work as per the direction of Engr-in-Charge. |
| 3 | Substation attendant Cum DG Operator cum Panel opearator-1 |
| 4 | Substation attendant Cum DG Operator cum Panel opearator-2 |
| 5 | Substation attendant Cum DG Operator cum Panel opearator-3 |
| 6 | Substation attendant Cum DG Operator cum Panel opearator-4 |
| 7 | Engaging an Lift operator for day to day ( 2 Nos) Lift Operator is responsible for the safe operation of elevators and lifts. Here are some common duties and tasks associated with this role:Loading and Unloading: Lift Operators assist passengers in safely loading and unloading ski lifts or other types of elevators.Safety and Comfort: They ensure the safety and comfort of passengers during lift operations.Maintenance: Operators maintain the lift area, keeping it clean and organized. They also implement emergency procedures when necessary.Evacuation: In case of disabled lifts or emergencies, Lift Operators evacuate passengers as per established protocols.[Supervision: Some operators supervise the lift operations ] (Semi-Skilled-2 nos) ITI with 1 Year experience Operation & maintain of Lifts. |
| 8 | Lift operator-1 |
| 9 | Lift operator-2 |
| 10 | Engaging a Fire Fighting Technician for day to day maintenance and operation of Fire pump house by operating of Diesel Engine,Jockey pump,Booster pump, presurization pump, terrace pump, diesel pumpmaintenance of fire panels and other equipments pertains to fire fighting system etc to maintain required water pressure at all times in External and internal fire hydrants, Hose reels etc complete all as directed by Engineer in charge. ( 1 No - Fire fighting technician- skilled) (ITI Certificate with 3 Years Experience in Fire Safety). |
| 11 | Engaging an Electrician for day to day maintenance of Electrical works like repairs to internal and external electric supply by replacing the worne out fittings/fixtures , reparing the unserviceable fittings/ fixtures such as switches, sockets, switch boards, LT Panels , MCBs, MCB DBs, MCCBs, SFUs FSUs etc and all types of fans/ light fittings, OH lines, UG cables, DG Set etc complete all as directed by the Engineer-in-charge. (3 nos Electrician- Skilled) (ITI Certificate with 3 Years Experience). (1 electrician for Hospital and 2 elctricians for outer ESI campuses) |
| 12 | Electrician-1 |
| 13 | Electrician-2 |
| 14 | Electrician-3 |
| 15 | Helper to Electrician for day to day maintenance of Electrical works like repairs to internal and external electric supply by replacing the worne out fittings/fixtures , reparing the unserviceable fittings/ fixtures such as switches, sockets, switch boards, LT Panels , MCBs, MCB DBs, MCCBs, SFUs FSUs etc and all types of fans/ light fittings, OH lines, UG cables etc ... complete all as directed by the Engineer-in-charge. ( 3 nos Un Skilled) (1Helper for Hospital and 2 Helpers for outer ESI campuses) |
| 16 | Helper-1 |
| 17 | Helper-2 |
| 18 | Helper-3 |
| 19 | Helper to Panel opearator/fire technician/ RO Plant operation/Electrical Pumps operating for day to day maintenance of Electrical works like repairsEngaging a Helper to assist technical staff such as HT/LT Panel Operators, Fire Pump Technicians, RO Plant Operators, and Electrical Pump Operators in routine operations and preventive/corrective maintenance activities likeAssisting in electrical fault isolation and repair, Supporting maintenance of LT/HT panels, control wiring, MCCs, etc.Handling tools, material shifting, and cleaning of electrical panels,Support during routine RO plant checks and backwashingincluding water supply and Coordinating during shutdowns, emergency operations, and safety drills complete all as directed by the Engineer-in-charge. ( 1 nos Un Skilled) |
| 20 | 1.5 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable |
| 21 | 2.5 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable |
| 22 | 4.0 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable |
| 23 | 6.0 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable |
| 24 | 10 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable |
| 25 | 20 mm iron staples/ saddles/ screws |
| 26 | 25 mm iron staples/ saddles/ screws |
| 27 | 20 mm dia. ISI marked, PVC conduit |
| 28 | 25 mm dia. ISI marked, PVC conduit |
| 29 | 32 mm dia. ISI marked, PVC conduit |
| 30 | 20 mm PVC bends |
| 31 | 25 mm PVC bends |
| 32 | 20 mm PVC couplers |
| 33 | 25 mm PVC couplers |
| 34 | 20 mm PVC junction box, one way |
| 35 | 20 mm PVC junction box, two way |
| 36 | 75 mm X 75 mm X 50 mm PVC box |
| 37 | Modular GI box for 2 module |
| 38 | Modular GI box for 3 module |
| 39 | Modular GI box for 4module |
| 40 | Modular GI box for 6 module |
| 41 | Modular GI box for 8 module |
| 42 | Modular GI box for 12 module |
| 43 | S.P. 5/6 amps, one way modular switch, ISI marked |
| 44 | S.P. 15/16 amps, one way modular switch, ISI marked |
| 45 | 3 pin 5/6 amps modular socket outlet, ISI marked |
| 46 | 6 pin 15/16 amps modular socket outlet, ISI marked |
| 47 | Modular blanking plate |
| 48 | Modular base & cover plate for 2 module |
| 49 | Modular base & cover plate for 3 module |
| 50 | Modular base & cover plate for 4 module |
| 51 | Modular base & cover plate for 6module |
| 52 | Modular base & cover plate for 8module |
| 53 | Modular base & cover plate for 12module |
| 54 | PVC Batten/Angle Holder |
| 55 | Supply of 6 amps. to 32 amps. ratings , SP MCB, \\"C\\" curve, 10 KA breaking capacity |
| 56 | Supply of Single pole, Blanking plate |
| 57 | Supply of 63 amps., 4 pole isolator |
| 58 | Supply of 63 amps. rating, 4 pole RCCB, 30mA |
| 59 | Supply of 20 amps. SPN, industrial type socket outlet, with plug top and metal chained cover in sheet steel enclosure |
| 60 | Supply of Aluminium lugs for 16 sq. mm cable |
| 61 | Supply of Aluminium lugs for 25 sq. mm cable |
| 62 | Supply of Aluminium lugs for 35 sq. mm cable |
| 63 | Supply of Aluminium lugs for 50 sq. mm cable |
| 64 | Supply of Aluminium lugs for 70 sq. mm cable |
| 65 | Supply of Aluminium lugs for 95 sq. mm cable |
| 66 | Supply of Aluminium lugs for 120 sq. mm cable |
| 67 | Supply of Aluminium lugs for 150 sq. mm cable |
| 68 | Supply of Aluminium lugs for 185 sq. mm cable |
| 69 | Supply of Aluminium lugs for 225 sq. mm cable |
| 70 | Supply of Aluminium lugs for 240 sq. mm cable |
| 71 | Supply of Aluminium lugs for 300 sq. mm cable |
| 72 | Supply of 16 mm X 50 mm bolts and nuts with washers |
| 73 | Supply of 16 mm X 125 mm bolts and nuts with washers |
| 74 | Supply of Steel fastener 6 mm X 75 mm |
| 75 | Supply of Steel fastener 8 mm X 75 mm |
| 76 | Supply of Rubber/ PVC bushes |
| 77 | Supply of 10 mm X 25 mm long G.I. bolt with nut etc |
| 78 | Supply of GI saddles 19mm x 0.55mm for conduit |
| 79 | Supply of GI saddles 25mm x 0.90mm for conduit above 25mm |
| 80 | Supply of 250 mm X 200 mm H.T. danger notice plate |
| 81 | Supply of 200 mm X 150 mm M.V. danger notice plate |
| 82 | Supply of Coke |
| 83 | Supply of Salt |
| 84 | Supply of Industrial type pressure gauges with gun metal / brass valves |
| 85 | Supply of Industrial type thermometres. |
| 86 | Supply of 36 watt LED Panel light 2x2 ft. (System lumen efficacy ≥105 1.20 mm) Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) |
| 87 | Supplying of 18 Watt LED Recessed/surface Down lighter (Round / square/ Rectangular)LED Down lighter (COB Type) (System lumen efficacy ≥ 105 < 120 lm/Watt ) of following body materials. Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector |
| 88 | Supplying of 18- 22 watt LED surface mounted Batten light (System lumen efficacy ≥105 <120 lm/Watt) of following body materials. Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) Make:Havells/Philips/Crompton/Wipro |
| 89 | Supply and fixing 7W / 9W LED Bulb Make:Havells/Philips /Crompton /Wipro |
| 90 | Supply and fixing 15W LED Bulb Make:Havells/Philips/Crompton/Wipro |
| 91 | Supply of ceiling fan with Brush Less Direct Current (BLDC) Motor 1200mm, BEE 5 star rating, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 92 | Supply AC Exhaust Fan 300mm (12”) Sweep (Light Duty) |
| 93 | Supply of 300mm Sweep WALL MOUNTING FAN |
| 94 | Supply and fixing Surface Box [Supply and fixing SURFACE MOUNTING BOXES (PLASTIC) - HIGHER END] - 3 Module |
| 95 | Supply and fixing Surface Box [Supply and fixing SURFACE MOUNTING BOXES (PLASTIC) - HIGHER END] - 6 Module |
| 96 | Supply and fixing 5 Amps 3 Pin & 2 Pin Combined Flush Type Wall Socket only |
| 97 | Supply and fixing 25A Modular PVC Box type Wall Socket with C-20A/C-25A Single Pole MCB protected AC socket with Plug Top Make : Havells/orbit/anchor/MK/Legrand |
| 98 | Supply of PVC /cotton tape Role (10 Mtrs) |
| 99 | Supply of Empire tape Role (10 Mtrs) |
| 100 | Supply and Fixing of 4 Pin LED PL-L-4P Round/squared 18W LED bulb/light suitable for existing panel lights Make: Havells/Philips/Wipro/Crompton |
| 101 | Supply and Fixing of Base socket for 4 Pin LED PL-L-4P Round/squared 18W LED bulb/light suitable for existing panel lights Make: Havells/Philips/Wipro/Crompton |
| 102 | Supply of 3 Core 2.5 Sqmm with ISI marked Flat Copper cable of ISI for Submersible Motors confirming to IS: 694:1990.Makes:Finolex/RRKabel/Polycab/Havells/KEI/ Gloster/ Goldmedal / GM/ Finecab/ Million/ APAR(Anushakthi) |
| 103 | Supply of 155 X 210 X 92 Sizes thermo-plastic cable junction boxes with IP66/67 weatherproof, for outdoor installation with knockouts for cable entry including terminals etc., complete (sizes in mm).Make : Hensel/Sadhrish |
| 104 | Supply and fixing of LED Post top lantrne/ Gate light fitting of 25 Watts, with 4000K colour temperature, IP 65 with LED Lamp all as directed by the Engineer-in-Charge. Make-Havells Mini Ruby Post Top LED Lamp or equivallent make of Philips. |
| 105 | LED Street light fixture 36 watt, Supplying, installation, Testing & Commissioning of 50 watt Street light LED fixture with powder coated pressure die cast aluminum body (System lumen efficacy >135 lm/Watt) |
| 106 | LED Street light fixture 50 watt, powder coated pressure die cast aluminum body (System lumen efficacy >135 lm/Watt) Supplying, installation, Testing & Commissioning of 50 watt Street light LED fixture. |
| 107 | M&L for Earthing with GI Earth pipe 4.5 mtr long, 40 mm dia including acessories and providing masonary enclosure with cover plate and locking arrangements and water pipe of 2.7 metre long etc, with earth electrode, charcoal and salt all as specified and as directed by the Engr-in- Charge. |
| 108 | S&F including providing and laying earth connection from earth electrode with 4 mm dia copper wire in 15 mm dia GI pipe from earth electrode including crimpting with copper thimble excavation and refilling as required at site on surface or in recess all as specified and as directed by the Engr-in- Charge. |
| 109 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. above 35 sq.mm and upto 95 sq.mm |
| 110 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 111 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 112 | Supply and transportation of 16 Sq mm X 4 core coreXLPE insulated, 1100V gradearmoured aluminum cable as per specification confirming to IS:7098 (Part- I)./1554-I U.G. CABLES Makes: Torent / Universal / Unicab / Havells / Finecab / KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt |
| 113 | Supply and transportation of 25 Sq mm X 4 core XLPE insulated, 1100V gradearmoured aluminum cable as per specification confirming to IS:7098 (Part- I)./1554-I U.G. CABLESMakes: Torent / Universal / Unicab / Havells / Finecab / KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt |
| 114 | Supply and transportation of 35 Sq mm X 4 core XLPE insulated, 1100V gradearmoured aluminum cable as per specification confirming to IS:7098 (Part- I)./1554-I U.G. CABLESMakes: Torent / Universal / Unicab / Havells / Finecab / KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt |
| 115 | Supply and transportation of 50 Sq mm X 4 core XLPE insulated, 1100V gradearmoured aluminum cable as per specification confirming to IS:7098 (Part- I)./1554-I U.G. CABLESMakes: Torent / Universal / Unicab / Havells / Finecab / KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt |
| 116 | Supply and transportation of 70 Sq mm X 4 core XLPE insulated, 1100V gradearmoured aluminum cable as per specification confirming to IS:7098 (Part- I)./1554-I U.G. CABLESMakes: Torent / Universal / Unicab / Havells / Finecab / KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt |
| 117 | Supply and transportation of 95 Sq mm X 4 core XLPE insulated, 1100V gradearmoured aluminum cable as per specification confirming to IS:7098 (Part- I)./1554-I U.G. CABLESMakes: Torent / Universal / Unicab / Havells / Finecab / KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt |
| 118 | Supply and transportation of 120 Sq mm X 4 core XLPE insulated, 1100V gradearmoured aluminum cable as per specification confirming to IS:7098 (Part- I)./1554-I U.G. CABLESMakes: Torent / Universal / Unicab / Havells / Finecab / KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt |
| 119 | Supply & Fixing of D.O.L Starter 415V, 3 phase, 50Hz..enclosed with no volt coil and overload protection with necessary materials, etc., complete suitable for 5 to 7.5 HP |
| 120 | Supply & Fixing of D.O.L Starter 415V, 3 phase, 50Hz..enclosed with no volt coil and overload protection with necessary materials, etc., complete suitable for 10 HP |
| 121 | Supply and fixing of 4.0 KVA 1-phase, automatic Electronic Voltage Stabilizer.Makes: V-Guard / Real Guard / Uni Stab / ITL |
| 122 | Rewinding of 5.0 H.P.- three phase motor of 1400 to 2800 RPM including all necessary material and of the same characteristics as original with required size of super enameled wire 'E' class insulation material and testing etc. as required make it in perfect working condition. |
| 123 | Servicing and repair of 5 HP /7.5 HP submersible pump including dismantling, cleaning, lubrication, supply and replacement of mechanical seals, impellers or diffusers as required, major overhauling with shaft alignment and balancing, reassembly, testing for flow/pressure and commissioning at site, including labour, hoisting/lowering, transport and handling charges complete as directed. |
| 124 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100 A,30KA,FPMCCB |
| 125 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.250 A,36KA,FPMCCB |
| 126 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board includingdrilling holes in cubicle panel, making connections, etc. as required. 400 A, 50KA, FPMCCB |
| 127 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 630 A, 50KA, FPMCCB |
| 128 | Supply and fixing of 230V/ 275V, 50Hz rating of 20-60 micro farad.Starting capacitor |
| 129 | Supply and fixing of 230V/ 275V, 50Hz rating of 15-36 micro farad.Running capacitor |
| 130 | Supply and fixing Supply and filling of R-22 Refrigerant Gas |
| 131 | Removing of existing Split Air Conditioners without damaging to copper pipe. |
| 132 | Repairs and Installation of existing PCB in 1.0 / 1.5 /2.0 Ton Split A.C. Unit |
| 133 | Servicing the Split type 1/1.5/2.0 Ton AC Machine by Cleaning through the water jet pump with condenser cooling Coil etc., by blower and oiling the Fan Motor for the indoor and outdoor units and Cleaning all parts and putting the machine in working condition and charging the refrigeranet gas if required basis only at site all as directed by the Engr-in-Charge.(Note :1. If requirement of refrigerent gas is essential basis will be measured and paid under separate item. ie.for methodology by weighing the gas cylinder before and after charging for how much gas have been charged.2. Otherwise servicing only accounted for this item). |
| 134 | Supply and fixing of CT operated direct reading type Ammeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. Below 500 A /Above 500A Make: Conzerve/Elmeasure/Meco/HPL/L&T/ socomec: Digital type (96 mm x 96 mm) |
| 135 | Supply and Fixing of 240/220 V, LED (22.5 mm dia) Pilot lamp with integral circuit, terminal block, including connection etc. as required : Red/yellow/Green colour |
| 136 | Supply and Fixing of 240/220 V, LED (22.5 mm dia) Pilot lamp with integral circuit, terminal block, including connection etc. as required :Blue colour |
| 137 | Supply and fixing of push button actuators and integral contact block of dia. 22.5 mm including making connection etc. as required. Make:Seimens/ ABB/ Schneider/L&T/C&S/HPL : Non-luminous type |
| 138 | Routine maintenance of 1250 KVA transformer, including testing of insulation resistance, oil breakdown strength. Reconditioning / replacement of silica zel,cleaning of transformer and topping upto oil level ifrequired (extra cost will be paid for oil). |
| 139 | Testing of Transformer oil for dielectric breakdown strength. |
| 140 | Supply of new and tested transformer oil as per IS-335 - 1972 (per Ltr) |
| 141 | Filtration of transformer oil as per ISS specifications filters to dielectric strength above 40KV …….at site. (Per Ltr) |
| 142 | Painting to 1250 KVA transformer with 2 coats Zinc chromate red oxide duly scraping existing paint followed by 2 coats of hammer ton grey paint etc., complete. |
| 143 | Supply and fixing of 12V 180 AH SMF battery with 3 years warranty, including wire leads, connections etc complete. Makes: Quanta / Racket / Exide. |
| 144 | Supply and fixing of 12V 18 AH SMF battery with 3 years warranty, including wire leads, connections etc complete. Makes: Quanta / Racket / Exide. |
| 145 | Supply and fixing including Transportation of 5 HP Three phase open well ISI submersible motor pumpset confirms to IS 14220: 1994. .Makes: Kirloskar / Crompton / Texmo / CRI /KSB/Lubi/ PSG/ ARYEN VARSHA /Falcon/Prithvi |
| 146 | Supply and fixing of stored pressure ABC (Mono Ammonium Phospate) Powder Type Fire Extinguisher of 6 kg. capacity as per IS:15683 with pressure gauge, discharge hose & control nozzle, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc, complete as per standard specification and as directed by the Departmental Officers. Make: EXCELLENT / SAFETY FIRST / EQUIVALENT |
| 147 | Supply Installation Testing and commissioning of self-healing MPP/MP type shunt capacitor Heavy duty Three phase 440 V, 50 Hz capacitor (Bank) conforming to IS:13340-41 / IEC :831-1&2 in existing panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector ( PSD ) and shall have dissipation factor less than 0.0025 at 50 Hz and total wattage loss less than 0.5 Watt per KVAR. including making connections with suitable capacity conductors/cables testing as required. |
| 148 | Supply and fixing of 440 Volt 3 pole capacitor (AC 6 B) duty contactor with 3 no. early make and post break auxiliary contacts in series with quick discharge damping resistors/ reactors to limit the inrush current, conforming to IS:13947-4-1/IEC:947-4-1, Din rail mounting type including making connections, testing etc. as required. suitable for 21 to 25 KVAR capacity capacitor bank. |
| 149 | General servicing & preventive maintenance of 100 HP electric pump motor including IR test, terminal check, lubrication, alignment verification, cleaning, and test run by authorized technician etc.. In the presence engineer in -charge |
| 150 | General servicing & preventive maintenance of 12.5 HP electric pump motor including IR test, terminal check, lubrication, alignment verification, cleaning, and test run. In the presence engineer in -charge |
| 151 | General servicing & preventive maintenance of 20 HP electric pump motor including IR test, terminal check, lubrication, alignment verification, cleaning, and test run. In the presence engineer in -charge |
| 152 | General servicing & preventive maintenance of diesel engine-driven fire pump (DG set type), including inspection and servicing of the fuel system (tank, lines, sedimenter), battery terminals & charger, cleaning of air/oil/fuel filters, lubrication check, radiator cleaning, and full test run of pump to be done by OEM authorized agency or experienced diesel mechanic . Excludes cost of consumables like filters, oil, and spares. In the presence engineer in -charge |
| 153 | General servicing & preventive maintenance of 800A, 11 kV VCB, including internal cleaning, lubrication, inspection of vacuum interrupters, tightening of terminations, interlock & mechanism check, insulation resistance test, manual/electrical operation testing of Relay,CT, PT,Breaker Electrical Testing and submission of report. Work to be carried out with approved tools and as per IS/CEA safety norms. |
| 154 | Sipply &Fixing Pressure Gauge0-10 Kg/Cm2 with swiphon including taking down the old one as directed by Engr-in-Charge. |
| 155 | Servicing and cleaning of existing Smoke detector and fire alarm system to made fully functional the visual indication, monitoring system including connections, interconnections and made functional for the locking arrangements with key including proper checking for loop connections and fixing new batteries as required at site etc all as directed by the Engr-in-Charge. Note:- Batteries will be measured and paid under separate items. |
| 156 | Quarterly preventive maintenance of 4000 LPH RO Plant including inspection and servicing of high-pressure pump/motor, cleaning of dosing pumps, NRVs, and pipelines, backwashing of multimedia and activated carbon filters, checking of control panel and safety interlocks, testing of water quality, replacement of pre-filters (sediment, carbon, and PP cartridges), replenishment of antiscalant (~5 L) and membrane cleaning chemical (~1 kg citric acid), supply of service consumables, deployment of one service engineer, one technician and one helper for one full day, and inclusive of local conveyance/ travel as applicable, complete in all respects (excluding major spares like membranes, pumps, motors or rewinding, which shall be charged separately). |
| 157 | Painting of 6.0 m street light pole (MS tubular/swaged type) including thorough surface cleaning with wire brush/emery paper to remove rust, dust & loose paint, application of one coat approved anticorrosive metal primer and two coats of approved synthetic enamel paint of specified shade, including thinning, provision of brushes/consumables, and all lead, scaffolding/ladder work, complete as directed by Engineer-in-Charge. |
| 158 | Carrying out minor welding works on existing street light poles/pipes/structure including surface preparation by cutting/grinding, welding with suitable electrodes (E6013 or equivalent) using portable welding set, rectification of cracks, base plate, brackets/fittings as required, finishing the welded portion with grinding, application of primer, and one coat of synthetic enamel paint of approved shade, complete as directed by the Engineer-in-Charge. |
| 159 | Testing of earth pit including measurement of earth resistance using digital 3/4-wire earth resistance tester (fall-of-potential method or clamp/three-wire as applicable), providing site test certificate, signed by authorized technician, and submission of soft/hard copy report, complete as directed by Engineer-in-Charge. |
| 160 | Comprehensive servicing and testing of 1000A LT Air Circuit Breaker (ACB), including dismantling of arc chutes, thorough cleaning of fixed and moving contacts with approved solution, lubrication of mechanical moving parts, checking and adjustment of interlocks and auxiliary circuits, servicing of spring charging motor and ON/OFF mechanism, calibration and relay setting (LSIG / microprocessor-based), insulation and continuity testing, and restoration of the ACB to full serviceable condition with test operation, through manufacturer’s authorized service agency, all as per OEM standards and as directed by the Engineer-in-Charge. |
| 161 | Comprehensive servicing and testing of 1600A LT Air Circuit Breaker (ACB), including dismantling of arc chutes, thorough cleaning of fixed and moving contacts with approved solution, lubrication of mechanical moving parts, checking and adjustment of interlocks and auxiliary circuits, servicing of spring charging motor and ON/OFF mechanism, calibration and relay setting (LSIG / microprocessor-based), insulation and continuity testing, and restoration of the ACB to full serviceable condition with test operation, through manufacturer’s authorized service agency, all as per OEM standards and as directed by the Engineer-in-Charge. |
| 162 | Comprehensive servicing and testing of 3200A LT Air Circuit Breaker (ACB), including dismantling of arc chutes, thorough cleaning of fixed and moving contacts with approved solution, lubrication of mechanical moving parts, checking and adjustment of interlocks and auxiliary circuits, servicing of spring charging motor and ON/OFF mechanism, calibration and relay setting (LSIG / microprocessor-based), insulation and continuity testing, and restoration of the ACB to full serviceable condition with test operation, through manufacturer’s authorized service agency, all as per OEM standards and as directed by the Engineer-in-Charge. |
| 163 | Supply, installation, testing and commissioning of digital multifunction meter (MFM) suitable for LT Panel, flush mounting type, accuracy class 0.5 or better, 3 phase 4 wire, CT/PT operated (programmable ratio), with LED/LCD display for V, A, kW, kVA, kVAR, PF, Hz, kWh, demand, THD, etc., having RS-485 MODBUS communication port, including supply of all materials, making cutout in panel door, fixing, wiring, CT/PT integration, termination with ferrules, testing and commissioning complete as directed by Engineer-in-Charge. |
| 164 | Providing / conducting complete fire audit Including submission of fire audit report for the whole premises by Certified fire safety auditors / NABH-approved auditors / State Fire Dept (NOC) / Third-party expert agencies approved by Fire department. |
| 165 | Supply and placing of Rubber Mat 2m x 1m suitable for 11 KV installation confirming to IS |
| 166 | Supply and fixing of First Aid Box complete with all First Aid Medicines |
| 167 | Supply and fixing of Shock Treatment Chart fixed in glass frame |
| 168 | Supply and fixing of 4 Nos. Fire Buckets made out of 40 x 40 x 6mm MS Angle |
| 169 | Supply and fixing of Metallic Danger Board as required by the Electrical Authorities |
| 170 | Refilling of 4.5 kg CO₂ type Fire Extinguisher, including evacuation of existing gas, cleaning and inspection of cylinder, refilling with CO₂ gas confirming to IS 15683, pressure testing, fixing of discharge hose and horn, re-sealing, labeling, and affixing inspection tag complete as directed by Engineer-in-Charge. |
| 171 | Refilling of 6 kg ABC (Dry Chemical Powder) type Fire Extinguisher, including emptying of old powder, internal cleaning, refilling with ABC powder confirming to IS 14609, re-pressurizing with nitrogen, checking of pressure gauge, sealing, and affixing of refill/service tag complete as directed by Engineer-in-Charge. |
| 172 | Refilling of 2 kg ABC (Dry Chemical Powder) type Fire Extinguisher, including emptying of old powder, internal cleaning, refilling with ABC powder confirming to IS 14609, re-pressurizing with nitrogen, checking of pressure gauge, sealing, and affixing of refill/service tag complete as directed by Engineer-in-Charge. |
| 173 | Numbering of ceiling fan/ exhaust fan/ LED fittings/streetlights, Panels/DBs/Pumps /earthpits as required complete as directed by Engineer-in-Charge. |
| 174 | Rewinding of 0.5 H.P. To 1.00 H.P single-phase motor of 1400 RPM including all necessary material and of the same characteristics as original with required size of super enameled wire 'E' class insulation material and testing etc. as required. |
| 175 | Supply and Fixing of 24\\" (600mm) Wall mounting / Pedestal Air Circulators of Heavey Duty. Makes:: Crompton / Havells Turbo Force / Almounard |
| 176 | Supplying, laying/ fixing, testing and commissioning of 75 mm Thickness resin bonded fiber glass pipe section insulation having density 80 kg/cum or mineral wool (non combustible) having density of 144 Kg/ cu m duly covered with a layer of 120 gm/sqm polythene sheet (vapour barrier) on existing pipe and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date ) at joints etc. as per specifications and as required. |
| 177 | Supplying, laying/ fixing, testing and commissioning of 50 mm Thickness resin bonded fiber glass pipe section insulation having density 80 kg/cum or mineral wool (non combustible) having density of 144 Kg/ cu m duly covered with a layer of 120 gm/sqm polythene sheet (vapour barrier) on existing pipe and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date ) at joints etc. as per specifications and as required. |
| 178 | Supplying, installation, balancing and commissioning of fabricated at site GSS sheet metal Thickness 1.25 mm for rectangular/ round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, bends, transitions, reducers, end caps, collars etc as required complete in all respect in confirmation with IS : 655 and approved drawings and specifications of following Rectangle duct with fittings as required and necessary supporting arrangements for Duct 24mm Sheet. |
| 179 | Supply & fixing of Wire mesh 20 gauge |
| 180 | Supply and fixing of Weld mesh for existing Lovers |
| 181 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for 3½ × 25 sq. mm size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 182 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for 3½ × 35 sq. mm size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 183 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for 3½ × 50 sq. mm size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 184 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for 3½ × 70 sq. mm size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 185 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for 3½ × 95 sq. mm size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 186 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for 3½ × 120 sq. mm size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 187 | Supply and Transportation of 0.5 HP Single phase Mono block CI body motor pumpset confirms to IS 9079:2002 including testing & commisioning of the same.Makes : Kirloskar / Crompton / Texmo / CRI / KSB/Lubi /Havells Hi-flow V2 / PSG/ ARYEN VARSHA /Falcon/Suguna. |
| 188 | Supply and Transportation of 1 HP Single phase Mono block CI body motor pumpset confirms to IS 9079:2002 including testing & commisioning of the same.Makes : Kirloskar / Crompton / Texmo / CRI / KSB/Lubi /Havells Hi-flow V2 / PSG/ ARYEN VARSHA /Falcon /Suguna. |
| 189 | Credit for dismantled materials old battery upto 18 AH |
| 190 | Credit for dismantled materials Wall Mount Fan (Old) |
| 191 | Credit for dismantled materials Exhaust Fan (Old) |
| 192 | Credit for dismantled materials Street Light Fitting (LED/HPSV – Old) |
| 193 | Credit for dismantled materials LED Tube Light / Panel Light (Non-working) |
| 194 | Credit for dismantled materials LED Bulb (Non-working) |
| 195 | Credit for dismantled materials CFL Fitting – 2 Pin / 4 Pin (Old) |
| 196 | Credit for dismantled materials Fluorescent Tube Fitting (Old) |
| 197 | Credit for dismantled materials Fan Capacitor (Old) |
| 198 | Credit for dismantled materials Miniature Circuit Breaker (MCB – Old) |
| 199 | Credit for dismantled materials Distribution Board (MCB Box – Old) |
| 200 | Credit for dismantled materials Electrical Switches (Various) |
| 201 | Credit for dismantled materials 5A / 15A Sockets (Old) |
| 202 | Credit for dismantled materials Call Bell / Buzzer |
| 203 | Credit for dismantled materials Old Copper Wiring (Mixed Gauge, Insulated) |
| 204 | Credit for dismantled materials Aluminium Wiring (Scrap) |
| 205 | Credit for dismantled materials PVC Conduits / Flexible Pipes (Scrap) |
| 206 | Credit for dismantled materials Armoured UG Cable (Aluminium Core) – Scrapped |
| 207 | Credit for dismantled materials ( payment to be made to ESIC inliue of dismantled materials available while replacing with new fittings: obtained as old unserviceable Iron Scrap. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail