Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 2 | In all kind of soil upto 1.5m to 3.0m. depth |
| 3 | In all kind of soil upto 3.0m to 4.5m. depth |
| 4 | In all kind of soil upto 4.5m to 6.0m. Depth |
| 5 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead up to 50m and lift up to 1.5m,as directed by Engineer-in-Charge. All kinds of soil |
| 6 | Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 7 | Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m. including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. Pipes, cables etc. exceeding 80mm dia. But not exceeding 300 mm dia. |
| 8 | Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m. including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. Pipes, cables etc. not exceeding 80mm dia. |
| 9 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1:2 (1 cement:2 coarse sand) to match the existing floor. With Chlorpyriphos/ Linadane E.C. 20% with 1% concentration. |
| 10 | Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift |
| 11 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 12 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) ,including cost of form- work,in foundation and floors. |
| 13 | Providing and laying in position cement concrete of specified grade excluding the ccost of centering and shuttering -All work up to plinth level: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size). |
| 14 | Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design: With 20x20mm square bar |
| 15 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. M.D. -10- Circular shape 500mm internal diameter |
| 16 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-incharge, upto 90 metre depth below ground level. Drilling of 300mm dia bore hole manually. |
| 17 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia |
| 18 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 19 | Supplying, filling, spreading & leveling gravels of size range 1.5 mm to 2mm, 5 mm to 10mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 20 | Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/medium/coarse, in required grading & size as per actual requirement, all complete as per direction of Engineer-in-charge. |
| 21 | Providing and laying Non pressure NP2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand ) including testing of joints etc. complete. 150mm dia. R.C.C. pipe |
| 22 | Providing and laying Non pressure NP2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand ) including testing of joints etc. complete. 250mm dia. R.C.C. pipe |
| 23 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of S.W./R.C.C. pipes including bed concrete as per standard design 150mm diameter R.C.C. Pipe |
| 24 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of S.W./R.C.C. pipes including bed concrete as per standard design 250mm diameter R.C.C. Pipe |
| 25 | Constructing brick masonry manhole with 75 class designation F.P.S. bricks in cement mortar 1:4 (1 cement : 4 coarse sand) RCC top slab with 1:2:4 mix (1 cement : 2 coarse sand: 4graded stone aggregate 20mm nominal size); foundation concrete 1:4:8 mix (1 cement :4 coarse sand: 8 graded stone aggregate 40mm nominal size) inside plasstering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design. a) Inside size 60x60 cm & 60 cm deep including C.I. cover with frame (light duty) total wt. of cover & frame to be not less than 38 Kg (wt. of cover 23 Kg & wt. of frame 15 Kg. |
| 26 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate |
| 27 | Making apron(with Drain & other )analysis |
| 28 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floorWith Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 29 | As in item No.8 above but in R.C.C. Raft foundation and footing with approved stone ballast. (Using 1:1.5:3 Mix concrete) |
| 30 | R.c.c. work with cement approved coarse sand and 2 cm. (3/4\\") guage approved stone ballast in the proportion 1:1.5:3,(1cement :1.5corse sand 3 grit) in Lintel excluding supply of reinforcement and its fixing and bending but including its fixing and binding the same necessary with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works of Beam , slab etc |
| 31 | As in item above but in R.C.C. columns in 1:1.5:3 having strength not less than M-20. |
| 32 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.All works above plinth level upto floor V level Concrete of M30 grade with minimum cement content of 330 kg /cum Water tank |
| 33 | Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size). |
| 34 | Painting on D.P.C. with two coats of airblown bitumen 85/50 or 85/25 @ 1.7 kg/sqm approx. including cost of fuel if any. |
| 35 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in .foundation and plinth in :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 36 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 37 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 38 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 39 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand) |
| 40 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 41 | Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth. |
| 42 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately).Second class teak wood |
| 43 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:-30mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 44 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:-35mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 45 | Providing and fixing ISI marked 35 mm flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters with one side decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality.1.0 mm thick |
| 46 | Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). |
| 47 | Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : 35 mm thick shutters With ISI marked stainless steel butt hinges of required size Second class teak wood |
| 48 | Mild steel or iron work of small sizes and sections such and holding down bolts, hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. Fabrication of hold fast for door chaukhats and windows. |
| 49 | Fabrication of Grill and Staircase Railling. |
| 50 | Providing and fixing fly and Mosquito proof stainless steel grade 304 wire mesh gaugewith 0.5 mm dia wire and 1.4 mm wire aperture |
| 51 | Providing and fixing chromium plated brass curtain rod having wall thickness of 1.25mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc., wherever necessary complete :25 mm dia |
| 52 | Fixing of M.S. Chaukhats (a) Door chaukhats |
| 53 | (b) Window chaukhats up to 1.5 sqm |
| 54 | (c) Ventilator chaukhats |
| 55 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 56 | 15mm thick plaster with cement mortar in proportion of 1:4 cement & Coarse sand) |
| 57 | 12 mm cement plaster in single coat on FAIR side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 C. sand |
| 58 | 15 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 C. sand |
| 59 | 25 mm thick Cement concrete floor with cement approved coarse sand and 2cm. Graded approved stone ballast laid in planels finished with 3mm (1/8\\") floating coat of neat cement or cement and marble dust in ratio of 5:1 as specified over and including 8 cm. (3\\") local sand and brick ballast 4 cm. gause in proportion of 1:4:8 and removing any giving then a uniform finish,including supply of all materials, labour, T&P etc. required for proper completion of the work. But without base concrete. |
| 60 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. [IN FLOORING] |
| 61 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. [IN SKIRTING] |
| 62 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :. [IN FLOORING] |
| 63 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. [IN SKIRTING] |
| 64 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levelsGranite of any colour and shade Area of slab upto 0.50 sqm |
| 65 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing he joints with white cement and matching pigment etc., complete |
| 66 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 67 | Two coat Wax or French polishing new wood work with approved ready made wax polish or approved French polish after rubbing down with sand paper, including supply of all material, labour and tools & plants etc required for proper completion of the work. |
| 68 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 69 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 70 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour. New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre . |
| 71 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 72 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :4.0 mm thick glass panes |
| 73 | Providing & fixing stainless steel sliding door bolts ISI marked required colour or shade with nuts and screws etc complete.250x16 mm |
| 74 | P/Fixing stainless steel tower bolts ISI marked to required colour or shade with necessary screws etc complete.250x10 mm |
| 75 | Providing and fixing Stainless Steel handles ISI marked to required colour or shade with necessary screws etc complete. 150mm |
| 76 | Providing and fixing stainless steel hanging floor door stopper with necessary screws etc. complete. Twin rubber stoper |
| 77 | Providing and Fixing of Door slincer including necessary screws etc complete |
| 78 | Providing & fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc. including welding, grinding, buffing, polishing & making curvature (wherever required) & fitting the same with necessary stainless steel nuts & bolts complete i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Eng-in-charge. (weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) |
| 79 | Chequerred precast cement concrete tiles 20 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). |
| 80 | Supply and filling of cinder in sunken in portion of building including breaking into required sizes including supply of all material, labour T&P required for proper completion of the work. |
| 81 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. (The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.) |
| 82 | Centering and shuttering including strutting, propping etc. and removal of form for : (a) Suspended floors, roofs, landings, balconies and access platform |
| 83 | (b) Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 84 | (c) Foundations, footings, bases of columns, etc. for mass concrete |
| 85 | (d) Columns, Pillars, Piers, Abutments, Posts and Struts |
| 86 | Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. 18 MM thick |
| 87 | Providing and fixing mild steel round holding down bolts with nuts and washer plates complete. |
| 88 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 89 | Z-Section steel windows (openable) |
| 90 | Fabrication and supply of T-iron 40x40x5mm door/window chaukhat frame including cost of steel, all carriage welding cutting, labour, grinding smooth finishing, staple plate 6 mm thick welded in back flange at hinges cost of 14 gauge hinges for 50mm size including all drilling, machine threading all screw, nuts, bolts, arrangment for looking of tower bolt, tie roo, hold fasts made of 25x3mm flat iron 15 cm long complete job including applying of one coat of red oxide steel primer paint required for proper completion of the work as per direction of Engineer in charge standard weight of actual weight ever is less than to be paid. and Angle iron door chaukhats 40*40*5 |
| 91 | Providing & fixing glazing in Z-section, windows, doors, ventilators shutters and partitions etc with Glass Putty/beading etc completion : with float glass panes 4.0mm thick |
| 92 | Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 93 | Supply and fixing M.S. Work in gate 'including all necessary for proper 'completion of the work. |
| 94 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade.Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture : (M.S. works). |
| 95 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : |
| 96 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : 125 mm |
| 97 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete |
| 98 | Inside size 90x120 cm & 90 cm deep including C.I. cover with frame (medium duty) total wt. of cover & frame to be not less than 116 Kg (wt. of cover 58 Kg & wt. of frame 58 Kg. |
| 99 | Extra for depth of man hole size 90x120 cm |
| 100 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) cement plastered on both sides with cement mortar ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : For pipes 250 to 300 mm diameter |
| 101 | Provding and fixing C.I. Double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc. if required will be paid separately. 50 mm dia |
| 102 | Providing & fixing G.I. pipes complete with G.I. fittings including tenching and refilling etc. 50mm nominal bore. |
| 103 | Providing & fixing G.I. pipes complete with G.I. fittings including tenching and refilling etc. 80mm nominal bore. |
| 104 | Providing & fixing sand of grading zone V or coaser grade alround the G.I. Pipes in external work. 50 mm diameter pipe |
| 105 | Providing & fixing sand of grading zone V or coaser grade alround the G.I. Pipes in external work. 80 mm diameter pipe |
| 106 | Providing and fixing gate valve (with cap complete with bolts, nuts, rubber insertion etc. 50 mm nominal bore |
| 107 | Providing and fixing gate valve (with cap complete with bolts, nuts, rubber insertion etc. 80 mm nominal bore |
| 108 | Constructing masonry Chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement :4 coarse sand ) for sluice valve, with C.I. surface box 100mm top diameter, 160mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design :With F.P.S. bricks |
| 109 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 50 to 80 mm dia nominal bore |
| 110 | Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres. [DSR-16.1] |
| 111 | Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge. (The panel shuttering work shall be paid for separately). |
| 112 | Providing and laying in position bitumen hot sealing compound for expansion joints etc. Using grade 'A' sealing compound. |
| 113 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in require |
| 114 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 115 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. W.C. pan with ISI marked white plastic seat and lid |
| 116 | Providing and fixing wash basin with C.I. brackets, 15 mm dia C.P. brass Single Hole Basin Mixture approved quality and make ,including painting of fittings and brackets, cutting and making good the walls wherever require. a) White Vitreous China wash basin size 550x 400 mm with 15 mm dia C.P. brass Single Hole Basin Mixture. |
| 117 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required . Kitchen sink with drain board 510x1040mm bowl depth 200mm |
| 118 | Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. Semi rigid pipe b) 40mm dia |
| 119 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 120 | Providing and fixing 8 mm dia C.P./S.S. Jet with flexible tube upto 1 meter long with S.S. triangular plate for Eureopean type W.C. of quality and make as approved by engineer-in-charge. 15mm nominal bore |
| 121 | Providing and fixing CP Brass 32 mm size Bottal Trap of approved quality & make and as per thedirection of Enginer-in-charge. |
| 122 | Providing and fixing CP Brass Single lever telephonic wall mixture of quality & make and as per thedirection of Enginer-in-charge. a) 15mm dia nominal dia. |
| 123 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet a) 100 mm diameter |
| 124 | Providing and fixing Toilet paper holder a) C.P. brass |
| 125 | Providing and fixing PTMT Liquid soap container 109 mm wide ,125 mm high and 112 mm distance from wall of standerd shape with bracket of the same material with snap fittings of approved quality and colour weighing not less than 105 gms. |
| 126 | Providing & fixing PTMT towl rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fitting arrangement of approved quality and colour. 600 mm. long towl rail length of 645 mm. width 78 mm. and effective height of 88 mm, weighing not less than 190 gms. |
| 127 | Providing & fixing 32 # G.I. Pipes spout including cutting & making good the walls etc. |
| 128 | Providing and laying cement concrete 1:5:10(1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size) around P.V.C /C.I. Soil and waste pipe including bed concrete as per standard design(embedded in the flooring / ground) 110/75 mm diameter |
| 129 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes. 110mm diameter |
| 130 | Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. Bend 87.5 degree 110 mm Bend |
| 131 | Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. Bend 87.5 degree 110 mm Bend110 mm Shoe |
| 132 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete. |
| 133 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110mm |
| 134 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. |
| 135 | Providing & fixing G.I. pipes complete with G.I. fittings & clamps including cutting & making good the walls etc. Exposed on wall 50mm dia nominal bore |
| 136 | Providing & fixing G.I. pipes complete with G.I. fittings & clamps including cutting & making good the walls etc. Exposed on wall 50mm dia nominal bore 80mm nominal bore. |
| 137 | Painting G.I. pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality. 50mm dia nominal bore. |
| 138 | Painting G.I. pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality. 80mm dia nominal bore. |
| 139 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. internal work -Exposed on wall 20mm dia nominal outer dia pipes |
| 140 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. internal work -Exposed on wall 25mm dia nominal outer dia pipes |
| 141 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. internal work -Exposed on wall 32mm dia nominal outer dia pipes |
| 142 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. internal work -Exposed on wall 40mm dia nominal outer dia pipes |
| 143 | Concealed work including cutting chases and making good the walls etc. 15mm dia nominal outer dia pipes |
| 144 | Concealed work including cutting chases and making good the walls etc. 20mm dia nominal outer dia pipes |
| 145 | Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 15mm nominal bore |
| 146 | Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15mm nominal bore |
| 147 | Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931 15mm nominal bore |
| 148 | Providing & fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. |
| 149 | Providing and fixing brass stop cock of approved quality. 15 mm nominal bore |
| 150 | Providing and fixing brass stop cock of approved quality. 20 mm nominal bore |
| 151 | Providing and fixing gun metal gate valve with wheel of approved quality. 32mm dia nominal bore |
| 152 | Providing and fixing gun metal gate valve with wheel of approved quality. 40mm dia nominal bore |
| 153 | Providing and fixing gun metal gate valve with wheel of approved quality. 50mm dia nominal bore |
| 154 | Providing and fixing gun metal gate valve with wheel of approved quality. 80mm dia nominal bore |
| 155 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) 32mm dia nominal bore |
| 156 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) 40mm dia nominal bore |
| 157 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) 50mm dia nominal bore |
| 158 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) 80mm dia nominal bore |
| 159 | Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m. including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. Pipes, cables etc. exceeding 80mm dia. But not exceeding 300 mm dia. |
| 160 | Providing and laying Non pressure NP2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand ) including testing of joints etc. complete. 150mm dia. R.C.C. pipe |
| 161 | Providing and laying Non pressure NP2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand ) including testing of joints etc. complete. 250mm dia. R.C.C. pipe |
| 162 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of S.W./R.C.C. pipes including bed concrete as per standard design 150mm diameter R.C.C. Pipe |
| 163 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of S.W./R.C.C. pipes including bed concrete as per standard design 250mm diameter S.W. Pipe |
| 164 | Providing and fixing square mouth S.W. Gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 Kg and frame to be not less than 2.70 Kg as per standard design: 150 x 100 mm. size P type With Sewer bricks conforming to IS : 4885 |
| 165 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design |
| 166 | Extra for depth of man hole size 90x80 cm |
| 167 | Inside size 90x120 cm & 90 cm deep including C.I. cover with frame (medium duty) total wt. of cover & frame to be not less than 116 Kg (wt. of cover 58 Kg & wt. of frame 58 Kg. |
| 168 | Extra for depth of man hole size 90x120 cm |
| 169 | Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement:3 coarse sand :6graded stone aggregate 20 mm nominal size) as per standard design With 20x20 mm square bar |
| 170 | Supply and fixing of UPVC S.W.R. pipe type-B confirming to IS-13592 including jointing the pipes with rubber ring,lubricant and UPVC SWR cupler confirming to IS-14735. Also including excavation of treanches cutting of walls and holes and repairing the walls,floors and refilling the trenches as before with supply and cost of other fIttlings such as elbow,bend,tee and y-tee,Cowel including supply of all marerial labour and T&P. Required for proper completion of work. 75 mm O.D. |
| 171 | Supply and fixing of UPVC S.W.R. pipe type-B confirming to IS-13592 including jointing the pipes with rubber ring,lubricant and UPVC SWR cupler confirming to IS-14735. Also including excavation of treanches cutting of walls and holes and repairing the walls,floors and refilling the trenches as before with supply and cost of other fIttlings such as elbow,bend,tee and y-tee,Cowel including supply of all marerial labour and T&P. Required for proper completion of work. 110 mm O.D. |
| 172 | Supply and fixing of UPVC S.W.R. Cowel confirming to IS-14735. Size 110 mm |
| 173 | Supply and fixing of UPVC S.W.R. pipe nahni trap size 100x75,110/90 mm confirming to IS-14735 self cleaning design fixed in PCC 1:2:4 and supply and fixing of 125 mm dia heavy duty CP brass jali. |
| 174 | Providing, fixing , testing & commissioning of motorised butterfly valve (with by pass line) with float type sensors suitable for 240 volts with working pressure rating of not less than 5 kg/cm2 with control panel and sensors to open valve when water level is low in tanks and to close when water level is high in water tanks including necessary cables, conduits, upto junction box, pipe, butter fly / ball valves etc., complete. 50 mm dia |
| 175 | Horticulture : Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. |
| 176 | Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, byspreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure). |
| 177 | Supplying and stacking of good earth at site including royalty and carriage upto 5 km lead complete (earth measured in stacks will be reduced by 20% for payment). |
| 178 | Supplying and stacking at site dump manure from approved source including carriage upto 1 km (manure measured in stacks will be reduced by 8% for payment) : Screened through sieve of I.S. designation 4.75 mm. |
| 179 | Carrigae of manure upto 5 K.M. |
| 180 | Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge. |
| 181 | Edging with bricks laid dry length wise, including required excavation, refilling, consolidating with hand packing and spreading surplus earth neatly within a lead of 50 m : Common burnt clay F.P.S (non modular) bricks of Classdesignation 7.5 |
| 182 | Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately |
| 183 | Providing and stacking of Nauclea cadamba (Kadam) of height 150-165 cm. in big poly bag of size 25 cm as per direction of the officer-in-charge. |
| 184 | Providing and stacking of Saraca indica (Sita Ashok) of height 105-120 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. |
| 185 | Providing and stacking of Phyllanthus emblica (Amla) of height 150-165 cm. in Big HDPE Bag as per direction of the officer-in-charge. |
| 186 | Providing and stacking of Schleichera trijuga (Kusum) of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge |
| 187 | Providing and stacking of Foxtail palm of ht. 240-270 cm bottom girth 35- 40 cm well developed in big size HDPE bags as per direction of the officer-in-charge. |
| 188 | Making tree guard 53 cm dia and 2 m high as per design from empty coal tar drums, suppliedfree by the department, including providing and fixing four legs 40 cm long of 30 x 3 mm M.S.flat riveted to tree guard and providing and fixing 2 nos M.S. sheet rings 50 x 0.5 mm fixedwith rivets complete in all respects including painting inside and outside of tree guard with |
| 189 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular type switch, modular plate, suitable size G.I. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group C |
| 190 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular type switch, modular plate, suitable G.I. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 191 | Wiring for circuit/sub-main wiring along with earth wire with the following size of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2X1.5 sqmm + 1x1.5 sqmm earth wire |
| 192 | 2X2.5 sqmm + 1x 2.5 sqmm earth wire |
| 193 | 2X4.0 sqmm + 1x 4.0 sqmm earth wire |
| 194 | 2X6.0 sqmm + 1x 6.0 sqmm earth wire |
| 195 | 4X10 sqmm + 2x 6.0 sqmm earth wire |
| 196 | Supplying and fixing Cable End Box(Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution borad, 240 Volts, on surface/recess, complete with testing and commissoning ect. as required. For 8 way, Double Door SPNMCBDB |
| 197 | Supplying and drawing following pair 0.5 sqmm FRLS PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/recessed steel/PVC conduit as required. 2 Pair |
| 198 | Supplying and drawing co-axial TV cable RG-6 graded, 0.7 mm solid copper conductor PE insulated,shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 199 | Supply and fixing of following size of PVC conduit alongwith the accessories in recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required: 25mm |
| 200 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. Telephone socket outlet |
| 201 | TV antenna socket outlet |
| 202 | Bell Push |
| 203 | Supply and fixing of two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 204 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 205 | Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 1 or 2 module(75mm X 75 mm ) |
| 206 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch,connection etc. as required. |
| 207 | Supplying and fixing following way, single pole and neutral sheet steel, MCB distribution board, 240 V on surface /recess complete with , tinned copper busbar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB / RCCB / Isolators). 8 way, Double door |
| 208 | Supplying and laying of aluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top as directed by Engineer-Incharge ,complete in all respect including excavation and refilling. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. |
| 209 | Supply & Fixing of service bracket of 50mm. Dia 4 meter long fabricated from class ''B'' G.I. pipe complete with two bend, socket, wall clamps. 7/3.15 mm G.I. stay wire, stay insulators etc..complete in all respects. |
| 210 | Supply and fixing following rateing four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 A,4P MCB-Bracking Capacity-10 kA, C-Curve-Make-Havells |
| 211 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch,connection etc. as required. |
| 212 | Supplying and fixing 3 pin 5 A ceiling rose on the existing junction box/woodedn block including connectionetc. as required. |
| 213 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. |
| 214 | Installation of exhaust fan in the existing opening, including making good the damage, connections, testing, commissioning etc. as required. upto 450 mm sweep. |
| 215 | Extra for fixing the louvers / shutters complete with frame fro exhaust fans of all sizes. |
| 216 | Providing and fixing circular/Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/M.S. sheet box by means of 3.3 mm dia round headed screwed, one loc at the conrners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. |
| 217 | DISTRIBUTION BOARDS, MCB'S & ISOLATORS : Providing & fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in in existing panel board including drilling holes in cubical panel, making connections,etc as required. 100 A, 30 KA, FPMCCB |
| 218 | Supplying and fixing following way, Horizontal type three pole and neutral MCB distribution board, 415 volts on surface /recess complete with , tinned copper busbar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB / RCCB / Isolators). 6 way (4 + 18), Double door |
| 219 | Supplying and fixing following way, Horizontal type three pole and neutral MCB distribution board, 415 volts on surface /recess complete with , tinned copper busbar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB / RCCB / Isolators). 4 way (4 + 18), Double door |
| 220 | 8 way (4 + 24), Double door |
| 221 | Supplying and fixing following way, surface/recess mounting,vertical type 415V, TPN MCB distribution board, on steel sheet, dust protected, duly power painted, inclusive of 200 A tinned copper busbar, common neutral link, earth bar, din bar, for mounting MCBs (But without MCBs and incomer) as required(Note:vertical type MCB TPDB is normally used where 3 phase outles are required.) 8 way (4 + 24), Double door |
| 222 | Supplying and fixing 5 amps. to 32 amps. rating, 240 volts `C' series, miniature circuit breaker (MCB) suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole |
| 223 | Supplying and fixing 5 amps. to 32 amps. rating, 240 volts `C' series, miniature circuit breaker (MCB) suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple Pole |
| 224 | Supplying and fixing single pole, blanking plate in the existing MCB DB complete etc. as required. |
| 225 | Supply and fixing 20 amp, 240 volts, SPN industrial Type, socket outlet ,With 2 pole and earth ,metal enclosed plug top along with 20 amp. `C` series SPMCB , in sheet steel encosure, on surface or in recess with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 226 | Providing and fixing M.V. danger notice plate of 200 mmx150 mm, made of mild steel, at least 2 mm thick, and viterous enameled white on both sides, and with incription in single red colour on front side as required. |
| 227 | Supplying and fixing Cable End Box(Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution borad, 415 Volts, on surface/recess, complete with testing and commissoning ect. as required. For 6 way, Double Door TPNMCBDB |
| 228 | For 8 way, Double Door TPNMCBDB |
| 229 | Suplying and fixing cable end box(Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution borad, 415 Volts, on surface/recess, complete with testing and commissoning ect. As required. For 4 way, Double Door TPNMCBDB |
| 230 | Supply and installing of following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, jointed with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 450mm width x 62.5mm depth x 2.0mm thickness |
| 231 | 600mm width x 62.5mm depth x 2.0mm thickness |
| 232 | Earthing with GI earth pipe, 600 mm X 600 mm X 6 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc, with charcoal/cock and salt as required. |
| 233 | Earthing with Copper earth pipe, 600 mm X 600 mm X 3 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc, with charcoal/cock and salt as required. |
| 234 | Supplying and Laying of 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection / terminating with nut, bolt, spring, washer etc. as required.( jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) |
| 235 | Supplying and Laying of 25 mm X 3 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection / terminating with nut, bolt, spring, washer etc. as required.( jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 236 | Providing & fixing 6 SWG dia G.I. on surface or in recess for loop earthing as required. |
| 237 | Supplying & making end termination with brass compression gland and aluminium lugs for the following size of PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 2 X 10 sqmm. (19mm) |
| 238 | 4 X 10 sqmm. (25mm) |
| 239 | 4 X 16 sqmm. (28mm) |
| 240 | 3.5 X 35 sqmm. (32mm) |
| 241 | 3.5 X 70 sqmm. (38mm) |
| 242 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and refilling etc as required. 100 mm Dia |
| 243 | 150 mm Dia |
| 244 | Supplying, installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round/square/Rectangular) SMD type of following body body material with PMMA and prismatic diffuser and construction as per IS: 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt,frequency 50/60 hz, Operating Complete in all respect i/c connection with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and earthing etc. as required with minimum 5 year OEM warranty. System lumen efficancy ≥120 and <135lm/watt output. LM79 & LM 80 test report from NABL lab for all testing required for LED fictures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in Charge as per requirement.(Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast/Extruded aluminum Body including trim 12-15 watt |
| 245 | LED Batten light (System lumen efficancy >135 lm/Watt) Supplying,installation, Testing & Commissioning of Batten light of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt,frequency 50/60 hz, Operating temp range-15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD<10%, P.F. ≥0.95, IP20,CRI>80,UGR(Unified Glare Rating)<19,Flicker free(Flicker should be below 5%), life time(LED,Driver & electrical circuitary), of minimum 50000 Buring Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K/4000°K/5700°K/6000°K/6500°K(As per ANSI Bim.)SDCM(Standard Deviation Colour Matching)<3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate(T.C.). Powder coated die cast/Extruded aluminum Body (Thickness ≥1.20mm) 18-22 watt |
| 246 | Manufactures Word Mark/Name Engraved/Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for testing facilities for LED fixtures. Complete in all respect i/c connection with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and earthing etc. as required with minimum 5 year OEM warranty. System lumen efficancy >135 lm/watt output. LM79 & LM 80 test report from NABL lab for all testing required for LED fictures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in Charge as per requirement.(Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). |
| 247 | Brush Less Direct Current(BLDC) Motor Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current(BLDC) motor, class of insulation: B, 3 nos. metel(Aluminum alloy)blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/AI body Power Factor not less than 0.9, Service Value(CM/M/W) minimum as below,350 RPM(tolerance as per IS: 374-2019), THD(Toatl harmonic Distortion) less than 10%, remote(preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C(max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan complient to IS 374:2019 fan supply, earthing etc. complete as required. 1200 mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 Cm/Min(Minimum) |
| 248 | Supplying and laying of aluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top as directed by Engineer-Incharge ,complete in all respect including excavation and refilling. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 10 sqmm 2 core |
| 249 | 10 sqmm 4 core |
| 250 | 35 sqmm 3.5 core |
| 251 | 70 sqmm 3.5 core |
| 252 | 300 sqmm 3.5 core |
| 253 | Supply, Installation, Testing and Commissioning of L.T. Panel vermin proof floor mounting, M.S. Channel Base with bottom and Fabricated out of 2.0/1.6 mm thik CRCA sheet steel painted with powder coated paint of shade as per the direction of Engineer I The feeder above shall be provided ac accommodated all measuring instrument shall be digital type & all indicating lights ahall be LED type. Wiring shall be done from 1100V Grade PVC Insulated copper flexible wire. All ACB shall be electricaly operated Draw out Type with microprosser based O/L, S/C & E/F Release off Breking/withstand capacity(ICU/ICs/Icw) 50 kA or more. All MCCB shall be thermal magnetics/microprossor with O/L & S/C protection along with required Spreders Extended rotary handle with pad locking facility of bracking capacity(ICU/ICS) 36 kA or more All MCB shall be Thermal 10kA 'C'Curve Cubical type switch board shall be Cat-A and B only.Incoming : 630Amp. MCCB - 1No Cat. B Panel Cubicale Type Metering :One (1) No. (0-500V) 96 x 96 Sqmm voltmeter with control fuse & selector switch.One (1) No. (0-630A) 96 x 96 Sqmm CT operated Ammeter with selector switch, CTs etc. One (1) Set of Phase Indication Lamp.Bus Bar : One (1) No.800 A, TPN aluminimum bus bar of suitable length. Outgoing : Phase indication lamps on each outgoing to be provided. 160 Amp. 4P MCCB- 01 No. 40 Amp. 4P MCB- 40 No. 125 Amp. 4P MCCB- 1 No. Spare 63 Amp. 4P MCB- 1 No. Spare 40 Amp. 4P MCB- 1 No. Spare |
| 254 | With provision for meter space EM-L.T. PANEL Incoming 160Amp. MCCB - 2No Cat. B Panel Cubicale Type Metering : One (1) No. (0-500V) 96 x 96 Sqmm voltmeter with control fuse & selector switch. One (1) No. (0-160A) 96 x 96 Sqmm CT operated Ammeter with selector switch, CTs etc. One (1) Set of Phase Indication Lamp. Bus Bar : One (1) No.200 A, TPN aluminimum bus bar of suitable length. Outgoing : Phase indication lamps on each outgoing to be provided. 100 Amp. 4P MCCB- 1 No. 63 Amp. 4P MCB- 3 No. 32 Amp. SP MCB- 1 No. 25 Amp. SP MCB- 1 No. 63 Amp. 4P MCB- 1 No. Spare 40 Amp. 4P MCB- 1 No. Spare |
| 255 | With AMF Interlocking With provision for meter space Supply & Fixing of 1X17 W mirror light complete in all respects. Make-Philips or Eq |
| 256 | Supply of 12 W LED BULB complete in all respect. Make-Philips or Eq |
| 257 | Supply of AC 230/250 Volts, 50 Hz 55w 1400 rpm exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required.Make: Havells-STANDARD -Refresh Air-SPS 300mm sweep. |
| 258 | Supply and fixing following rateing four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A,4P MCB-Bracking Capacity-10 kA, C-Curve-Make-Havells |
| 259 | 63 A,4P MCB-Bracking Capacity-10 kA, C-Curve-Make-Havells |
| 260 | S/f of 10 pair Junction Boxes for Floors and building with Krone connectors , with connection and punching of same |
| 261 | Supply and fixing of Single Unit LED aviation obstruction light complete with Transformer and LED spiral etc. complete in all respects.Make-Bajaj or Eq |
| 262 | LIGHTING ARRESTER :Supply & fixing of level-I tested accordance with NFC-17-102 for advance triggering time 22 micro seconds, temperature with stand test of -40 to +120 degree centigrate, CE marked, short circuit test for 100KA etc. inculding the following: Make Liva/ESE(kalre)-50mtr. |
| 263 | SITC 5m GI mast with adaptor head and base plate for raising the lighting rod by 5 m above the surface to protected including insulator between lighting rod and GI mast. |
| 264 | SITC Copper cable 70 sqmm flexible copper single core multi-strand. |
| 265 | SITC 6 digits IP 67 lighting counter with hole for cable/strip LEC-D |
| 266 | SITC Eathing set(2 Nos.) consisting of copper bounded rod 17.2mm dia 10ft long 250 microns UL marked, 30kg earth enhancing chemical compound with resistivity of <0.1 Ohm-m NABL lab tested, clamp for connecting rod to cable/strip including civil work with pit cover complete. |
| 267 | SITC stay wire,lugs, U clam, base plate fastener, hook fasteners, Test link/clamp ect. As required complete. |
| 268 | Fire Fighting :(A) Supplying, Installation, Testing & Commissioning of Electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required:(Terrace Pump)TEFC type suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, confirming to IS-325.(D) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.900 lpm at 35 m head |
| 269 | Providing, laying, testing & Commissioning of 'C' class heavy duty MS pipe confirming to IS 3589/IS1239 inculding welding, fittings like elbows,tees, langes,tapers,nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of syntetic enamel paint of required shade complete as required: 25 mm dia |
| 270 | 100 mm dia |
| 271 | Supplying & fixing single headed internal yard hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel, ISI marked, confirming to IS 5290(type A) with blank Gunmetal/Stainless Steel cap and chain as required: Single headed Gunmetal |
| 272 | Supplying, fixing, testing & commission of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets confirming to IS 13095 of following sizes as required: 100 mm dia |
| 273 | Supplying & fixing orifice plate made out of 6 mm thick stainless steel(grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required: |
| 274 | Providing, installation, testing and commission of non-return valve of following sizes confirming to IS: 5312 complete with rubber gaskets GI bolts, nuts, washers etc as required: 100 mm dia |
| 275 | Supplying & fixing 63 mm dia, 15m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. confirming to IS 636(type-A) as required: Gun Metal |
| 276 | Supplying & fixing First-aid hose Reel with MS construction spray painted in post office red,conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic(Textile reinforced) type-2 as per IS:12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipments on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 30 m |
| 277 | Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle confirming to IS:903 suitable for instantaneous connection to interconnect hos pipe coupling as required. Gun Metal |
| 278 | Supplying & fixing air vessel made out of 250 mm dia,8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required. |
| 279 | Providing & fixing of pressure switch in M.S. pipe line including connection etc as required. |
| 280 | Supplying, installation, testing & commissioning of heat detector operating at 54/57 degree centregrate with rate of rise cum fixed temperature(dual thermistor) type with mounting base complete with all connection etc. as required. |
| 281 | Supplying, installation, testing & commissioning of smoke detector operating with builtin LED and mounting base complete with all connection etc. as required. |
| 282 | Supplying, installation, testing & commissioning of Manual call Boxes of MS constuction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required. |
| 283 | Supplying, installation, testing & commissioning responce indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required. |
| 284 | Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box(16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching trasformer etc. complete as required. |
| 285 | Supplying, installation, testing & commissioning talk back slave station in surface/recess suitable for operation on simplex mode complete with P.T.T. knob & speaker/microphone cenclosed in a M.S. box(16 SWG)/ABS box with break glass in front etc. complete as required. |
| 286 | Supplying & laying of 2X1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. |
| 287 | Supplying & laying 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. |
| 288 | Supply and fixing of following sizes of medium class PVC conduit alongwith the accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required: 25 mm |
| 289 | Supplying, installation, testing & commissioning of main control and indicating panel made out SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections, interconnections etc complete as required. 10 Zone panel for fire alarm system 250 Watt amplifier racks suitable for operation on 230V AC/24VDC supply confirming to IEC-268-3 complete with all accessories as required-2 Nos.(one to act as standby) Battery charger trickle cum boost to take complete load of fire alarm & PA system complete with all accessories including providing & fixing of 2 nos.12 volt, 60 AH each sealed maintenance free bateries-1 set. |
| 290 | Providing, laying, testing & Commissioning of 'C' class heavy duty MS pipe confirming to IS 1239/3589 i/c fitting like elbows,tee,flanges,tapers,nut bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as support, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. 100 mm dia |
| 291 | Providing, laying, testing & Commissioning of 'C' class heavy duty MS pipe confirming to IS 3589/IS1239 inculding welding, fittings like elbows,tees, langes,tapers,nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of syntetic enamel paint of required shade complete as required: 80 mm dia |
| 292 | Providing, laying, testing & Commissioning of 'C' class heavy duty MS pipe confirming to IS 3589/IS1239 inculding welding, fittings like elbows,tees, langes,tapers,nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of syntetic enamel paint of required shade complete as required: 100 mm dia |
| 293 | Supplying & fixing single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, confirming to IS 5290(type A) with blank Gunmetal/Stainless Steel cap and chain as required: Single headed Gunmetal |
| 294 | Supplying, fixing, testing & commission of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets confirming to IS 13095 of following sizes as required: 80 mm dia |
| 295 | Supplying, fixing, testing & commission of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets confirming to IS 13095 of following sizes as required: 100 mm dia |
| 296 | Providing, installation, testing and commission of non-return valve of following sizes confirming to IS: 5312 complete with rubber gaskets GI bolts, nuts, washers etc as required: 100 mm dia |
| 297 | Supplying & fixing 63 mm dia, 15m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. confirming to IS 636(type-A) as required: Gun Metal |
| 298 | Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle confirming to IS:903 suitable for instantaneous connection to interconnect hos pipe coupling as required. Gun Metal |
| 299 | Supplying & fixing of Fire brigade connection of cast iron body with gun metal male instantaneous inlet coupling complete with cap and chain as required. for suitable dia MS pipe connection conforming to IS 904 as required: 2 way-100 mm dia M.S. Pipe |
| 300 | Supply & fixing of fire extinguisher, ABC Type 6.00 kg. capacity(ISI Marked IS:15683 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 301 | Supply & fixing of CO2 type fire extinguisher, 6.5 kg. capacity(ISI Marked IS:2878 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 302 | Providing/Fixing of Fire Hose cabinet box made out of 18 gauge MS sheet including two coats of post office red paint over one coat of primer with 4 mm, thick glass door in front painted “FIRE” in red luminous paint. The size of the box should be 750 mm X 600 mm X 250 mm size capable of accommodating a pair of hose with coupling and nozzle. The box should be floor mounted type with railway coach lock arrangement and lever for opening the door after breaking the glass complete. Make : Standard/Lifeguard or EQ. |
| 303 | Providing & Fixing of 1.6 mm thick M.S / Door Frame, Door capable of accommodating fire Hose Reel, Landing Valve, Hose Pipes, fittings & accessories. The door shall have a front glass with lock and key arrangement & shall be painted with post office red colour (approval shall be taken on the basis of submitted sample before ordering).(Liasioing with civil contractor for making Recessed type mansoary box (by civil contractor). |
| 304 | Supplying and fixing of Self Glow Exit signage for stairs and exits made out from not less than 4 mm of transparent acrylic sheet of 300 x 150 mm size with self illuminated plastic words of 100 mm height suspended from ceiling by means of M.S. chain or fixed of the walls as required and as directed at site..(MAKE : Agni Suraksha (ASES) / Securiton-aka /System Sensor) |
| 305 | Supplying and fixing in position the following type of sign board made out of 3 mm thick\\"Opaque\\" PVC foam board with computer cut, PVC non-reflective self adhesive vinyl painted foam board, complete with mirror fasteners. Signage with the following text\\"IN CASE OF FIRE, USE STAIRS UNLESS INSTRUCTED OTERWISE\\" of 1.25 cm height letters in red with white back ground. The size of the board shall be 25 cmx30 cm and shall be fixed at the height of 2 mtrs. From finished floor near manual call points. |
| 306 | Floor identification signage(ie, GROUND FLOOR, etc) at the each stair & LIft enclosure on every floor, indicating the floor number in words, lettering size shall be 7.5 cm with contrasting colour from back ground shall be 15 cmx60 cm. |
| 307 | Supplying and fixing in position of Fire Escape Route Plan A2 size. |
| 308 | Supplying and fixing of Fire man axe. Make :- Agni Suraksha (ASES) or EQ |
| 309 | Supply, Installation, Testing and Commissioning of electronic siren with suitable audible range of 1 k.m. approximately 4 watt.complete in all respects. Make :- Agni Suraksha (ASES) or EQ. |
| 310 | Providing/Fixing of cubical type floor mounted Fire pump control panel fabricated from 16 G M.S. sheet duly powder coated finish of approved shade and comprising of : Incomer:-a) 63 amp 4 Pole MCCB, 50Hz with breaking capacity 10KW. b)One Volt meter (0-500 V) with selector switch. c) Ammeter (0-63 Amps.) with selector switch & CTs. - 1 Set d) Set of 3 phase indication lamps - 1 Set e) Set of Al bus bar 200 Amp 4 strip - 1 Set f) Selector switch for local/remote, auto/manual/off operation ON/OFF indication lamp etc. - 1 Set Outgoing:-1 x 63 Amps FP MCCB (25 KA) with Suitable HP fully automatic Star/Delta Starter with over load protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation. |
| 311 | Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required. 40mm dia |
| 312 | Supplying and drawing following size of FRLS PVC insulated copper conductor, single core cable in existing surface/ recessed medium class PVC conduit as required. 3X2.5 sqmm |
| 313 | Earthing with GI earth pipe, 600 mm X 600 mm X 6 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc, with charcoal/cock and salt as required. |
| 314 | Supplying and Laying of 25 mm X 3 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection / terminating with nut, bolt, spring, washer etc. as required.( jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 315 | Supplying and Laying of 6 SWG G.I wire at 0.50 metre below ground level for conductor earth electrode, including connection / terminating with G.I. thimble etc. as required. |
| 316 | Supplying & making end termination with brass compression gland and aluminium lugs for the following size of PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 2 X 6 sqmm. (19mm) |
| 317 | 2 X 10 sqmm. (19mm) |
| 318 | 4 X 10 sqmm. (25mm) |
| 319 | 3.5 X 70 sqmm. (38mm) |
| 320 | 3.5 X 300 sqmm. (70mm) |
| 321 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and refilling etc as required. 100 mm Dia |
| 322 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and refilling etc as required. 150 mm Dia |
| 323 | Supplying & laying of following size DWC HDPE pipe ISI marked alongwith all accessories like socket, bend, couplers etc. confirming to IS : 14930 Part-II complete with fitting, cutting & jointing etc. direct in ground (75cm below ground level) including excavation & refilling the trench but excluding sand cushioning & protective covering etc. as required. 90 mm dia (OD - 90 mm & ID - 76 mm nominal) |
| 324 | Supplying, installation, testing & commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars/lighting DBs for automatic switching On & Off of street lights at sunset & sun risr or twillight(Auto On, Auto Off, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c progamming at site complete required. 02 output per phase and suitable for single phase supply |
| 325 | LED Street light fixture, powder coated die cast alluminum body (System lumen efficancy >135 lm/Watt) Supplying,installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast alluminum body with driver as per the requirement with Driver efficiency >85%, input voltage AC 140-270 Volt,frequency 50/60 hz, Manufactures Word Mark/Name Engraved/Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for testing facilities for LED fixtures. Complete in all respect i/c connection with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and earthing etc. as required with minimum 5 year OEM warranty. System lumen efficancy >135 lm/watt output. LM79 & LM 80 test report from NABL lab for all testing required for LED fictures as per BIS shall be submitted. Powder coated die cast/Extruded aluminum Body (Thickness ≥1.20mm) 100 watt |
| 326 | Supplying and laying of aluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top as directed by Engineer-Incharge ,complete in all respect including excavation and refilling. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 6 sqmm 2 core |
| 327 | 10 sqmm 2 core |
| 328 | 10 sqmm 4 core |
| 329 | 70 sqmm 3.5 core |
| 330 | 300 sqmm 3.5 core |
| 331 | L.T. FEEDER PILLER Incoming : 1No. Of 630 Amps 4P MCCB of 36 KA service breaking capacity and 630 Amp trip setting. Metering : Voltmeter, Ammeter, Indication Bus Bar : 1 Set of 800 Amps TPN Aluminium Bus Bars of suitable length and of cross section . Bus bar shall be insulated by heat shrinkable sleaves & clip on shrouds for joints. Bus bar shall be designed to with stand a fault level of 36 KA at 415 volts. 3Nos. Phase indicating lamp each lamp shall have one toggle switch . Outgoing : Phase indication lamps on each outgoing to be provided. 630Amp 4P MCCB (36kA) - 1 Nos. 63Amp 4P MCB (10kA) - 2 Nos. |
| 332 | Supplying and making Indor cable end termination with heat shinkkable jointing kit complete with all accessories including lugs suitable for following sozeof 3 core, XLPE aluminium conductor cable of 11 grade as required. 70 mm |
| 333 | Supplying and making Outdorr cable end termination with heat shinkkable jointing kit complete with all accessories including lugs suitable for following sozeof 3 core, XLPE aluminium conductor cable of 11 grade as required. 70 sq mm |
| 334 | Supply, installation, testing and commissioning of following capacity (continuous loading) BEE 4 Star rated (Corresponding Level as per BIS amended upto date of receipt of tender) , 11/0.433 KV step down, 3 Phase, 50 Hz, complete with all accessories and safety provisions as per relevant IS 1180 (Part-3) including first filling of filtered dehydrated Synthetic organic Ester oil, For highly polluted atmosphere and special application external paint work shall be as per direction of Engineer-in-Charge. Design ambient condition : a) air temperature 50 deg C, b) Relative Humidity 90 % Max, c) Seismic Zone as per location of site, d) Altitude as per location/site. Noise level Shall not exceed limits as per NEMA TR-1 with all accessories running measured as per IEC 551 / NEMA standard. The transformer should have . Fitting and Accessories : The following fittings shall be provided:- a) Two earthing terminals with the earthing symbol b) Oil level gauge indicating oil level at minimum, Pressure relief device or explosion vent x). Monogram Plate y) Inspection cover z). Detachable type radiators with top and bottom shutoff valve. aa) Oil Conservator with Oil level indicator, minimum level marking and drain plug for all transformers of capacity 50 KVA and above. bb) Necessary hardware, clamps, lugs etc. for termination on HV/MV etc. for all transformers. 315 KVA |
| 335 | Supply, Installation, testing and commissioning of Automatic Power Factor Correction (APFC) panel, indoor type floor mounted free standing totally enclosed, extendable, (A) Incomers Suitable capacity MCCB Microprocessor base with O/C, S/C, E/L release of TPN 50KA breaking capacity (Ics=Icu), vi) Wiring of the control circuit shall be done by using 2.5 sq mm, FRLS 1100 V grade, PVC insulated multi stranded copper control wire. (C) Bus Bars 1.3 Amp per Sq.mm, TPN, Electrolytic grade Aluminum bus bar of capacity 1.25 times of incomer rating as per CPWD specification.(D) Outgoings (APFC Section) Selection of the capacitors combinations shall be for continuous rating 100 KVAR |
| 336 | Supplying and laying of aluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top as directed by Engineer-Incharge ,complete in all respect including excavation and refilling. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 300 sqmm 3.5 core |
| 337 | Supplying and laying of 3 core stranded aluminium conductor(Cross linked polyethylene) insulated PVC bedded, galvanized flat steel strip armoured cable confirming to I.S. 7098(Part II with latest amendments) 11 KV grade at the depth of 900 mm bellow ground level over a cushion of 100 mm thick fine rever sand all around and protected with well burnt bricks on side and on top put across as directed by Engineer-Incharge , complete in all respect including excavation and refilling. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 70 sqmm 3 core |
| 338 | Supply, installation, testing & commissioning of H.T. PANEL (11KV) indoor type floor mounted metal clad, IP 52, 11 KV VCB panel with 1 incomer and 2 out goings, totally enclosed & fully interlocked, horizontal drawout, horizontal isolation type breaker as per IS : 13118, as ammended upto date and additional specifictions, having capacities as mentioned below, single break, trip free mechanism, motorised charged and auto closing breaker suitable for use on 11 KV, 3 Phase, 50 Hz A. C. supply with short circuit fault level of 350 MVA, complete with self contained, fully interlocked, rack in and rack out mechanism, air insulated but encapsulated Aluminium alloy bus bars of suitable fault level, G.I. earth bar, earth bar, breaker featured with mechanical ON / OFF indicator with hand trip device, spring release coil, shunt trip coil, control voltage of 24 Volt DC, TNC, LED type indicating lamps for phases and trip conditions and auxiliary switch of 6 NO + 6 NC and equipped with following switchgears and accessories. The panel should be suitable for connections for up to 3 x 300 sq.mm XLPE 11 KV cable (cable entry from bottom), end termination with heat shrinkable jointing material etc. as required. Incoming - 1 No. 630 Amp. VCB with followings Make:- ABB/C&S or UPPCL approved make. |
| 339 | Supply, erection and commissioning of 2 pole structure for terminating 11 KV O.H. supply from State Electricity Boards as per specifications. The 2-pole structure shall comprise of: MS tubular swaged pole 11 mtrs high (410 SP 24 as per latest IS), in cement concrete foundation 1:3:6 (1 cement : 3 coarse sand : 6 graded aggregate 40mm nominal size) including excavation and refilling etc. as required. The rate shall be inclusive of painting with 2 coats of aluminium paint (on red oxide). The portion of pole under the ground shall be provided with 2 coats of bituminous paint - 2 Nos. Supply,installation, testing and commissioning of GI stay set complete with 20mm dia 1.8 M long stay rod with 450 x 450 x 7.5 mm anchor plate with thimbles, stay clamps, 7/4.00 mm dia GI stay wire, turn buckle (20mm x 600mm) strain insulator bow tightner in cement concrete 1:3:6 foundation as excavation and refilling - 2 Set |
| 340 | Supply, erection, testing and commissioning of 11 KV, 3 phase, 630 Amps central post racking type gang operated switch with earth switch complete with hardware, arcing horns, arcing contacts, vertical drop out fuses, down rod operating with locking devices, necessary MS channel/angle iron brackets, clamps insulators & connections etc. as required for earthed system and conforming to IS: 19813. |
| 341 | Supply, erection, testing and commissioning of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 30 KV (rms) with a nominal discharge current rating of 10 KA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required. |
| 342 | Supplying and fixing of 1200x1200x12mm GI plate, vertically earthing complete with 20mm dia GI pipe, a funnel for watering with hinged cover masonry housing alternate layer of coke and salt atleast 100mm thick all-around etc. complete as required confirming IS-3043 |
| 343 | (Supply, installation, Testing & Commissioning of 'Silent Type Diesel Generating set as per CPCB IV + or better norms along with having Prime Power Rating of KVA as below, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor, including testing at factory and site with fuel, load for test and other necessary arrangements Complete as per CPWD specifications, should have QR code which should contain drawing, test report OEM manual,Geo- Tag of manufacturing location, rating plate as per relevant IS Code etc. and consisting of the followings: A) Diesel Engine: Turbocharged Diesel engine 4 stroke water cooled, multi cylinder, dynamically balanced fly wheel, electric start of suitable BHP at 1500 RPM suitable for above FUEL TANK:Daily service fuel tank of suitable liters capacity as per CPWD Specifications, fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class 'C' pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications. (F) Exhaust System: Dry exhaust manifold with hospital type exhaust silencer and catalytic convertor. 62.50 KVA |
| 344 | Supplying and making cable end terminations with brass compression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. 3.5 X 70 sqmm. (38mm) |
| 345 | Earthing with GI earth pipe, 600 mm X 600 mm X 6 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc, with charcoal/cock and salt as required. |
| 346 | Supplying and Laying of 25 mm X 3 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection / terminating with nut, bolt, spring, washer etc. as required.( jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 347 | Supplying and laying of aluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed by the Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following size . 70 sqmm 3.5 core |
| 348 | Supply Installation , Testing & Commissioning of LIFTS with power operated centre opening doors and AC variable voltage & variable frequency control,car safety & Governor, Guides, guide rails, ropes, car platform, cabin finishes (stainless steel), car & landing doors (stainless steel), hoist motors, braking system, Automatic Rescue Device (ARD) etc. complete as per the CPWD Specifications and realated IS standards upto date. 13 Passenger,1.5 mps,4 stops , 4 Openings including all complete materials and labours (Incl All labour and Materials etc complete) Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail