| 1 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm.FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. |
| 2 | Group C. |
| 3 | SCIplaza/Finolex make |
| 4 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVCconduit as required. |
| 5 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 6 | 4 X 4 sq. mm + 2 X 4 sq. mm earth wire |
| 7 | S/D 2 X 1.5 sq. mm |
| 8 | S/D 3 X 1.5 sq. mm |
| 9 | S/D 2 X 2.5 sq. mm |
| 10 | S/D 3 X 2.5 sq. mm |
| 11 | S/D 2 X 4 sq. mm |
| 12 | S/D 4 X 4 sq. mm |
| 13 | S/D 2 X 6 sq. mm |
| 14 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 15 | SCI/plaza/Finolex make |
| 16 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. |
| 17 | 5/6 amps switch |
| 18 | 3 pin 5/6 amp socket outlet |
| 19 | 15/16 amp switch |
| 20 | 6 pin 15/16 amp socket outlet Piano Type |
| 21 | Make :- Schenider/L&T/Legrand |
| 22 | Supplying and fixing two rotary stepped type electronic fan regulator on the existing switch box including connections etc. as required. |
| 23 | Make :- Schenider/L&T/Legrand |
| 24 | Providing and installation of exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required:- |
| 25 | Exhaust Fan, Light duty, (Domestic) 300 mm sweep |
| 26 | Make:- Usha/Crompton/Havells |
| 27 | Providing and fixing LED Batten Light of IP40 Led fixture 40 W+/- 1W with Surface Mounted 4 Feet with Polycarbonate diffuser with Extruded aluminium housing having minimum system lumen output 1000 lumens and system lumen efficacy of 100 lm/W with P.F.>0.95 with THD<20% ,CRI 80 .The LED with Useful life of 50000 Hrs at L70 . The LEDs used in the luminaire shall have CCT of ANSI Bin 5700 K with CRI of minimum 80.The Input voltage range shall be 150V to 270V, 50/60 HZ complete with all accessories, including connections, testing and commissioning etc.as required complete in all respects. |
| 28 | Makes :- Panasonic /Phlips/ Wipro) |
| 29 | Supplying and fixing batten/ angle holder including connection etc. as required. |
| 30 | Makes :- Anchor /SSK/ Cona) |
| 31 | Supplying and fixing of Segregated tripple pole and neutral 4 ways surface/ recess mounting, 7 Segment 415volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, with provision to mount MCCB incomer, DP MCB/RCCB sub-incomer in each phase and SP MCBs as outgoing (but without MCB ’s and incomer),complete with tinned copper din-bar, wire-set, neutral link, earth bar, detachable gland plate, cable interconnections, including earthing etc. as required:- |
| 32 | TPN Phase Segregated DB 4 way, horizontal typeAs per L&T cat no DBPGL004DD/ Legrand/Schneider make |
| 33 | L&T/Legrand/Schneider make |
| 34 | Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, neutral link, earth bar, din-bar, interconnections, powder painted, including earthing etc. as required:-(But without MCB/RCCB/Isolator) |
| 35 | Double door-12 way |
| 36 | L&T/Legrand/Schneider make |
| 37 | Supplying and fixing of 6 amps. to 32 amps. rating, 240/415 volts,10 kA 'C' curves, miniature circuit breaker suitable for inductive load of following poles in the existing miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections testing and commissioning etc. as required:- |
| 38 | 6 Amp to 32 Amp Single pole. Cat-A. |
| 39 | L&T/Legrand/Schneider make |
| 40 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 41 | 40 Amps. Cat-A. |
| 42 | L&T/Legrand/Schneider make |
| 43 | Supplying and fixing following rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 44 | 40 Amps. Cat-A. |
| 45 | L&T/Legrand/Schneider make |
| 46 | Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
| 47 | 100 A - 125A 18 KA |
| 48 | L&T/Legrand/Schneider make |
| 49 | Earthing with copper earth plate 600mmx600mmx3mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. etc. ( with charcoal or coke and salt ) complete as required. |
| 50 | Providing and laying earthing connection from earth electrode with 4.00mm dia copper wire in 15mm dia G.I pipe from earth electrode including connection with copper thimble excavation and re-filling as required |
| 51 | Supplying and fixing 4.00 mm dia copper wire on suface or in recess for loop earthing required . Please Enable Macros to View BoQ information |