| 1 | Taking down carefully copper/aluminium point wiring (light, fan, socket and power point) complete fittings such as switches, ceiling rose, regulators, socket etc and removing material from site and making good disturbed surfaces of walls, floors/ceiling to match the existing surface all as spfd and directed |
| 2 | Taking down care fully sub main wiring/service wire of any description. |
| 3 | Point wiring complete with 1.5Sq.mm nominal area of copper conductor FRLS multi stranded PVC insulated and unsheathed 1100 volts cable drawn through & including PVC Casing & caping with standard accessories such as elbows, tees, junctions etc. and PVC moulded terminal box with top cover of including PVC insulated unsheathed solid 1.5Sqmm copper conductor cable as continuous earth lead all as specified and directed for the followings:- |
| 4 | One light/exhaust fan point controlled by one way switch |
| 5 | One switch socket outlet 6 Amps, 230 volts point on Same board |
| 6 | One switch socket outlet 6 Amps, 230 volts point on independent board |
| 7 | All as item No 3 above, but using cables 4 Sq mm size for independent power point. |
| 8 | Supply and fix lamp holder insulated body with back plate complete all as specified and directed by Engr -in-charge. |
| 9 | Supply and fix Switch piano flush button single pole 6 Amps 230 volts one way complete all as specified and directed by Engr -in-charge. |
| 10 | Supply and fix, of switch Socket out let two in one 5 pin 6 Amps flush type.230 volts complete all as directed. |
| 11 | Supply and fix, of switch Socket combination out let multi purpose 5 pin 6 Amps and 16Amps 230 volts complete all as directed. |
| 12 | Supply and fix, of switch Socket combination out let multi purpose two in 1 flush type 6 Amps 230 volts complete all as directed. |
| 13 | Supply and fix, of Ceiling rose, surface Bakelite three terminals complete all as directed. |
| 14 | Supply and fix in replacement of sheet metal enclosure for DBs double door when MCB's to be used single pole & neutral 240 Volts 8 Ways complete all as specified and directed by Engr -in-charge. |
| 15 | Supply and fix in replacement of MCB SPN 63 Amp, 240 Volts, AC, ISI marked, 'C' curve complete all as specified and directed by Engr -in-charge. |
| 16 | Supply and fix in replacement of MCB SP 6-32 Amps. 240 Volts 50 HZ, AC, ISI marked, 'C' curve complete all as specified and directed by Engr -in-charge. |
| 17 | M & L for submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/recessed as required in PVC casing Caping wire size 2 x 6.0 sq. mm + 1x 6.0 sq. mm earth wire complete all as specified and directed by Engr -in-charge. |
| 18 | Supply and Fixing only in Replacement LED light fitting 1x 20 W, 220 V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engr -in-charge. |
| 19 | Supply and fix in replacement LED luminaire 600mm x 600 mm, 35/36 watt,220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cable of suitable size complete all as specified and directed by Engr-in-charge |
| 20 | Supply, fixing, connecting and testing LED security light fitting 35 watt, 230 volt, AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp with impact and corrossion resistant incl thermal management in multiple optics including bracket and fixing arrangements with IP 65/66 protection complete all as specified and directed by Engr -in-charge. |
| 21 | Supply and fix in replacement of 4 way double door TPN Vertical load line DB suitable for Flush/surface mounting with 160 Amp & 250 Amp copper bus bar with neutral & earth bars including MCCB 160 Amp TPN as incomer and fixing arrangements for SPN/TP MCBs as outgoing and making good disturbed surfaces of walls, floors, etc. complete all as specified. |
| 22 | Supply and fix in replacement MCB SP 63 Amp, 240 Volts, AC, ISI marked, 'C' curve complete all as specified and directed. |
| 23 | M&L for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part -I and connected to earthing test point all as specified or indicated including testing on completion Note The charcoal , common Salt and any other items required for getting the value are included in this rate . |
| 24 | Supply and fix Air Circulator fan, steel body AC single Phase 230V of size 300mm sweep with blades, and frame and louvers complete all as specified and directed by Engr-in-charge. |
| 25 | Supply, laying and testing cable XLPE in replacement Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35.0 sq mm 4 core complete all as specified and directed |
| 26 | M&L for Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for laying UG cable in trenches on plan and n exc 1.5 m in depth in any type of soil and getting out complete all as specified and directed. |
| 27 | M&L for Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25m, complete all as specified and directed. |
| 28 | M&L for Removing excavated material to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the strating point, complete all as specified and directed. |
| 29 | M&L for Sand cushioning to underground cables 8 cm below the cable before laying & 15 cm above the cable after laying, complete all as specified in clause 19.75 of SSR Par-I, complete all as specified and directed. Note : Punned thickness will be measured and paid. |
| 30 | Supply and laying of factory made, machine pressed, unreinforced, pre-cast concrete cable cover class LV type-2 flate size 250 mm x 150 mm x 40mm , complete all as specified and directed. |
| 31 | Deduct Schedule of Credit of Rs (-) 15692.50 (Minus) as listed in Schedule 'A' (Contd). Contract Sum shall be arrived after deducting the credit amount.Note :- Tenderers will not quote against this item being a firm amount. Please Enable Macros to View BoQ information |