| 1 | M&L for wiring from indoor unit to outdoor unit of size 2.50 sqmm PVC insulated multistranded FRLSH four core round cable including fixing of thimbles for fixing in compressor terminals for split type Air Conditioner 1.5/2.0 TR capacity inclduing taking down old unserviceable complete all as specified and directed. |
| 2 | Excavating over areas, exc 3m deep and n exc 4.5 m and getting out in any type of soil |
| 3 | S&F socket out let 2 in 1, 3 pin 5 Amp flush type (ISI Marked) |
| 4 | M&L for 15 mm thick rendering in CM 1:6 on on stone masonary with water proofing compound by weight of cement finished fair complete all as specified and directed. Note : Water proofing compound will be measured and paid seperately. |
| 5 | M & L for Laying APP modified water proofing membrane weighing not less than 3 Kg/Sqm will be laid over applied bitumen |
| 6 | M&L for concealed point wiring for controlled by one switch with PVC insulated but unsheathed single core FRLSH multistranded copper conductor cable IS-694 marked of size 1.5 Sqmm (nominal area) in and including non metallic rigid PVC conduit 20 mm dia by cutting chases in walls by cutter and making good the surface in CM 1:3 and to the original specification and PVC conduit on ceiling for steel structure/surface conduit with clamps, gutties etc for RCC ceiling with including one run of PVC insulated FRLSH copper conductor cable of 1.5 Sqmm with green insulation as earth wire and connected to earth dolly including provision of pressed steel terminal box with 3mm thick plastic laminated sheet top cover for housing switches,sockets etc concealed on wall complete all as specified and directed. (a) One fan/exhaust fan point controlled by one, one way switch |
| 7 | M&L for applying two coats of cement base paint on wall over a coat of priming paint including preparation of new plastered or un-plastered surfaces, complete all as specified and directed. |
| 8 | M&L for concealed point wiring for controlled by one switch with PVC insulated but unsheathed single core FRLSH multistranded copper conductor cable IS-694 marked of size 1.5 Sqmm (nominal area) in and including non metallic rigid PVC conduit 20 mm dia by cutting chases in walls by cutter and making good the surface in CM 1:3 and to the original specification and PVC conduit on ceiling for steel structure/surface conduit with clamps, gutties etc for RCC ceiling with including one run of PVC insulated FRLSH copper conductor cable of 1.5 Sqmm with green insulation as earth wire and connected to earth dolly including provision of pressed steel terminal box with 3mm thick plastic laminated sheet top cover for housing switches,sockets etc concealed on wall complete all as specified and directed.(a) One socket outlet 3 Pin, 6 Amp on same board. |
| 9 | M & L PCC (1:2:4) type B-0 using 12.5mm graded stone agg as in Roof padding,levelling course or similar work compl all as specified & directed |
| 10 | M & L for excavation over area each additional 1.5m or part thereof in depth beyond the first 1.5 m,in any type of soil complete all as specified and directed. |
| 11 | M & L for Laying APP modified water proofing membrane weighing not less than 3 Kg/Sqm will be laid over applied bitumen by torch apllication method |
| 12 | Taking up or down 20mm bore steel tubing and connection complete all as specified and directed. |
| 13 | S&F inlcuding taking down unserviceable MCB’s of any type. S & F MCB, 6 to 32 Amp, SP, 240 Volt. complete all as specified and directed. |
| 14 | S&F 25mm bore steel water tubing medium grade galvanized including fittings and fixed to walls, ceilings, floors or laid in floors complete all as specified and directed. |
| 15 | M & L for rendering 10mm thick in CM 1:4 on ceiling surface finished even and smooth without using extra cement complete all as specified and directed. |
| 16 | M&L for RCC M-25 Design mix (using 20mm graded crushed stone aggregate) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs,under-reamed piles and mass concrete complete all as specified and directed |
| 17 | Supply and fix Electronic fan regulator 230 volts, step type,socket type ,hum free 120 watt ISI Marked,including taking down unserviceable. |
| 18 | Demolition of PCC block/stone masonery built in cement mortar of any specification and in any position complete all as specified. |
| 19 | 1. Taking down carefully aluminium point wiring on wooden battens/through conduit (light fan, socket or power) complete with fittings such as switches, wooden batten, ceiling roses, pendants, regulators, box type tube light fittings, removing the materials from site except fittings etc which shall be reused in the work and making good the disturbed surfaces of walls/ceiling/ floors etc complete all as specified and as directed by Engineer-in-Charge |
| 20 | M&L for disconnecting, dismantling, taking down outdoor and indoor of Spilt AC having capacity 1.5/2 TR. |
| 21 | Supply & fixing in replacement heavy duty copper pipe 15mm (5/8\\") dia/ bore complete including brazing, welding, nuts, bolts and screws of required size including taking down old unserviceable one complete all as specified and directed. |
| 22 | M&L for Screed bed or bedding layer or mortar 15mm thick in cement mortar 1:3 with WPC finishing even and smooth with out using extra cement to receive roof treatment, mixed with water proofing compound as per manufacture instruction by weight of cement over cleaned roof surface as in gradin to RCC roof surface complete all as spd and dir. Note- water proofing compound shall be measured and paid separately. |
| 23 | M&L for Mild steel bars of 5 mm dia over and upto incl 10 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips in stiruups spacer and binders |
| 24 | M&L 100 mm thick cement concerete 1:2:4 type B-1 using 20mm graded aggragete in alternate bays all as specified and directed. |
| 25 | M&L for concealed point wiring for controlled by one switch with PVC insulated but unsheathed single core FRLSH multistranded copper conductor cable IS-694 marked of size 1.5 Sqmm (nominal area) in and including non metallic rigid PVC conduit 20 mm dia by cutting chases in walls by cutter and making good the surface in CM 1:3 and to the original specification and PVC conduit on ceiling for steel structure/surface conduit with clamps, gutties etc for RCC ceiling with including one run of PVC insulated FRLSH copper conductor cable of 1.5 Sqmm with green insulation as earth wire and connected to earth dolly including provision of pressed steel terminal box with 3mm thick plastic laminated sheet top cover for housing switches,sockets etc concealed on wall complete all as specified and directed.(a) One socket outlet 3 Pin, 6 Amp on independent board |
| 26 | Supply & fix aluminium strip 25mm x 3mm complete with saddles and fixing screws for fitting the strip. |
| 27 | M & L Formwork to faces of walls, retaining walls with fair finishes, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter complete all as specified and directed. |
| 28 | Disconnecting & taking down the existing unserviceable water tank and Supply and fixing 500 Litre capacity Rotational moulded polyethylene water storage tanks double layered (cylindrical vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-I. |
| 29 | M & L Pre-cast cement concrete block masonry with solid blocks type C1 1:3:6 (20mm garded agge) , exc. 10 cm in width and setting in mortar, complete all as and. |
| 30 | S&F in repairs 25mm bore Gun metal gate valve with iron wheel head, screwed both ends for iron pipe, ISI marked. |
| 31 | M&L for 10 mm thick external rendering in CM 1:6 on stone masonry or other than fair faces of concrete / brick is to be finished even and smooth (without using extra lime or cement) complete all as specified. |
| 32 | M&L for 15 mm thick rendering in CM 1:4 on brick or concrete surface with water proofing compound by weight of cement finished even and smooth complete all as specified and directed. Note : Water proofing compound will be measured and paid seperately. |
| 33 | Demolition of brickwork or stone/boulder/PCC block masonry, built in cement mortor including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stone work and precast concrete articles |
| 34 | M&L for Applying evenly a tack coat of in dustrial bitumen 85/25 at the rate of 1.2 kg per sq.m including cleaning surfaces |
| 35 | M&L for point wiring for controlled by one switch with PVC unsheathed single core multistranded copper conductor cable of size 4 Sqmm (nominal area) in and including PVC conduit 20 mm dia by cutting chases in walls by cutter and making good the surface in CM 1:3 and to the original specification and PVC conduit on ceiling for steel structure/surface conduit with clamps, gutties etc for RCC ceiling including one run of PVC insulated FRLS copper conductor cable of 4 Sqmm with green insulation as earth dolly for 6 pin, 16 Amp socket outlet on Independent board. |
| 36 | M&L for 15mm thick rendering in CM 1:4 on stone masonary with water proofing compound by weight of cement finished fair complete all as specified and directed. Note : Water proofing compound will be measured and paid seperately. |
| 37 | M&L 75 mm thick cement concerete 1:4:8 type D-2 using 40mm graded aggragete all as specified and directed. |
| 38 | Supply only liquid water proofing compound complete all as specified and directed. |
| 39 | M&L for ceiling rose, surface Bakelite 65 x 17.50 mm of three terminals PVC/Polycarbonate,isolated body (ISI Marked) |
| 40 | Demolition of cement concrete (un reinforced) in Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work and any portion ordered to be dismatled of any thickness as specified and directed. |
| 41 | M&L for Machine cut kota stone slab flooring 20-25mm thick over 15 mm thick (1:6) cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbingand p olishing complete all as specified and directed |
| 42 | M&L for applying three coats of white wash on walls including preparation of new plastered or un-plastered surfaces, complete all as specified and directed. |
| 43 | M&L for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete |
| 44 | S & F in replacement Refrigerant piping insulation with \\"O\\" class closed cell electrometric nitrile rubber tubular insulation and complete all as directed by engg-in-charge |
| 45 | Supply and fixing Surface and wall mounted LED tube light fittings of cap 20W , four feet Basic all purpose surface and wall mounted LED batten with polycarbonate housing including taking down with all as specified and directed. |
| 46 | Supply & fix Prewired Distribution Board factory made sheet metal enclosure double door distribution board class IP-43 IK 09 with 200 Amp rated bus bar 240 Volts 8 way (2 + 6 way) single pole and neutral including taking down complete all as directed by Engineer-in-Charge. |
| 47 | S&F switch piano flush type single pole one way 15 Amp (ISI Marked) |
| 48 | M&L for Reinforced cement concrete M-25 design mix type B-1 (1:2:4) using 20 mm aggregate in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like |
| 49 | S&F inlcuding taking down unserviceable MCB’s of any type. S&F MCB, 32 Amp, SPN, 240 Volt complete all as specified and directed. |
| 50 | Demolition of cement concrete (reinforced) in Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work and any portion ordered to be dismatled of any thickness as specified and directed. |
| 51 | Returning/filling in approved excavated soil including spreading, levelling, watering and well ramming in layers n exc 25 cm complete all as specified and directed. |
| 52 | S&F socket out let 2 in 1, 3 pin 15 Amp flush type (ISI Marked ) |
| 53 | Removing excavated material exc 5 km and n exc or upto 15 Km depositing where directed at a level n exc. 1.5 m above the starting point |
| 54 | Supply & fixing in replacement Outdoor Unit (ODU) Stand for 1.5TR/ 2 TR Type split AC complete all as specified & as directed. |
| 55 | Disconnecting upto 1000 ltr capacity existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately) |
| 56 | M&L for 25mm thick Wearproof granolithic metallic hardner concrete as specified in manufacturer instructions (included metallic hardner) and as directed by Engr -in- Charge. |
| 57 | M&L for RCC M-25 Design mix (using 20mm graded crushed stone aggregate) as in Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses complete all as specified and directed |
| 58 | Supply (in company sealed cylinders of any capacity) and charging refrigerant gas R-22,R-32,R-407 for filling in compressors as per requirement complete all as specified and directed by Engr-in-charge. |
| 59 | M&L for PCC (1:3:6) type C-1 using 20 mm graded as in copings, like including weathering, slightly rounded or chamfered angles and throating, as directed |
| 60 | Materials and labour for preparation of new steel surface of any description not otherwise described exc 10cm width or girth and applying two coats of synthetic enamels paints over a coat of red oxide primer all as specified |
| 61 | Taking down chowkats or frames with shutters without taking off shutters from the frames, area exc 1.50 sqm but n.exc 4 Sqm each and removal to store including cutting holes for removal of hold fast complete all as specified |
| 62 | M & L for excavation over area not exceeding 1.5 metre deep and getting out in any type of soil, complete all as specified and directed. |
| 63 | M&L 75MM thick PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as sub base. |
| 64 | M&L for PCC(1:2:4) Type type B-1using 20 mm graded aggregate as in surface channels complete all as specified and directed by Engg-in-charge. |
| 65 | M&L for galvanized steel water tubing medium grade of 25mm bore with & including all fittings complete laid in trenches. |
| 66 | S&F 4.00 mm thick Sheet glass, ordinary quality and glazing with oil putty in square exc 0.5 sq. m in each pane complete all as specified |
| 67 | Demolition of Brick work of stone/boulder masonry, built in cement mortar excluding ashlars facing dressed stone work and pre-cast concrete etc complete all as specified. |
| 68 | M&L for preparation of roof surfaces by brushing, cleaning and Applying a priming coat with bitumen primer @ 0.5 ltr/Sqm |
| 69 | M&L for Mild steel TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips etc complete all as specified and directed. |
| 70 | Taking up or down 25mm bore steel tubing and connection complete all as specified and directed. |
| 71 | M & L for PCC(1:3:6) Type C-1 Pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width and setting in mortar CM(1:6)complete all as specified and directed by Engg-in-charge. |
| 72 | M&L for porceiline insulator suitable for fixing earthing strip to the wall / floor etc complete with necessary nuts, bolts and fixing material complete all as specified and as directed |
| 73 | M&L for concealed point wiring for controlled by one switch with PVC insulated but unsheathed single core FRLSH multistranded copper conductor cable IS-694 marked of size 1.5 Sqmm (nominal area) in and including non metallic rigid PVC conduit 20 mm dia by cutting chases in walls by cutter and making good the surface in CM 1:3 and to the original specification and PVC conduit on ceiling for steel structure/surface conduit with clamps, gutties etc for RCC ceiling with including one run of PVC insulated FRLSH copper conductor cable of 1.5 Sqmm with green insulation as earth wire and connected to earth dolly including provision of pressed steel terminal box with 3mm thick plastic laminated sheet top cover for housing switches,sockets etc concealed on wall complete all as specified and directed. (a) One light point controlled by one, one way switch |
| 74 | Supply and fixing of ceiling metal electrical fan box , round or square shape all are specified and directed by engr in charge |
| 75 | M&L for 10 mm thick rendering in CM 1:6 on on stone masonary with water proofing compound by weight of cement finished fair complete all as specified and directed including taking downNote : Water proofing compound will be measured and paid seperately. |
| 76 | Disconnecting upto 500 ltr capacity existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately) |
| 77 | M&L form work to sides of concrete with fair finishes, foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work, vertical or to batter. |
| 78 | Supply and fixing in repair GI Pipe light grade, 40mm dia , galvanized, with all fittings complete all as specified and directed |
| 79 | M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. surface finished fair and smooth |
| 80 | M&L for Squared rubble walling, Jodhpur type brought upto courses, well bonded, bedded and solidly hearted, built in CM 1:6 |
| 81 | M&L for Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips |
| 82 | M & L Preparation of newly plastered ceiling surfaces and applying three coat of white wash. (above item shall be applied by the brush not by spray gun) |
| 83 | Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide surface finished fair and smooth |
| 84 | M&L 100mm thick cement concerete 1:2:4 type B-1 using 20mm graded aggragete in alternate bays all as specified and directed. |
| 85 | M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; surface finished fair and smooth |
| 86 | M & L for PVC (SWR) 110mm dia pipe single socketed in any length with rubber ring joints for weep holes complete all as specified and directed. |
| 87 | Refixing old steel water tubing 25 mm dia with and including new GI fittings and connected to new or old positions of walls, ceilings, floors etc complete all as specified and directed. |
| 88 | M&L for Powder coated Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.) hinge type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified |
| 89 | S&F switch piano flush type single pole one way 5 Amp (ISI Marked) |
| 90 | Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. |
| 91 | M&L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick surrounded with charcoal and salt, buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron 15 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as directed.(i) The concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I.(ii) Item includes the cost of 7.50m GI pipe for protection of earth wire/strip Any variation in length shall be adjusted through deviation order. (iii) Item includes cost of 7.50m earth lead wire/strip. Any variation in length shall be adjusted through deviation order.(iv) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate. |
| 92 | M&L test point terminal block made of gun metal or phosphorus bronze 75X75X25 mm thick with arrangement by making 2 Nos of hole suitable with and 2 Nos of nuts, bolts & washer of 8mm dia for fixing GI strip all as specified. |
| 93 | M&L for Powder coated aluminium section in door frame ,swing door, sliding window and partition walls complete including connecting accessories like allu grill for guard,fittings, glazing clips, handles, pivots etc fixed complete as directed by Engineer-in-Charge. |
| 94 | Supply & fixing in replacement heavy duty copper pipe 6mm (1/4\\") dia/ bore complete including brazing, welding, nuts, bolts and screws of required size including taking down old unserviceable one complete all as specified and directed. |
| 95 | M&L for 10mm thick rendering in CM 1:6 on brick or concrete surface with water proofing compound by weight of cement finished fair complete all as specified and directed. Note : Water proofing compound will be measured and paid seperately. |
| 96 | Demolition of cement concrete (unreinforced) in any position upto 50 mm in thickness (below or above ground level) complete all as specified and directed. |
| 97 | M&L for disconnecting, dismantling, taking down old unsv and S&F single pointed air termination aluminium rod 12mm dia, 300 mm dong |
| 98 | M & L for Post-insulation bundling and alignment work for AC unit suction pipe, discharge pipe, and electrical wire,drain pipe. The work involves neatly combining the insulated pipes and wire into a single assembly, securing them using UV-resistant nylon cable ties at uniform intervals to ensure proper alignment and appearance. Additional support is provided at bends and corners to prevent sagging and maintain a clean, aesthetic look, with binding intervals not exceeding 30 cm to ensure a well-organized and durable installation complete all as specified & as directed. |
| 99 | M&L for Refixing & complete testing commissioning outdoor and indoor of Spilt AC having capacity 1.5/2 TR. |
| 100 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200cmm sweep. Min air delivery 210 CFMcwith service value 6.00 BEE. Five starcrated with brushless direct current motorc(BLDC) in and including taking down of existing ceiling fan and deposition of the same in MES store yard at Jaisalmer complete all as specified and directed |
| 101 | Refixing old steel water tubing 20 mm dia with and including new GI fittings and connected to new or old positions of walls, ceilings, floors etc complete all as specified and directed. |
| 102 | M&L for 15mm thick rendering in CM 1:4 on stone masonary with water proofing compound by weight of cement finished fair complete all as specified and directed including taking downNote : Water proofing compound will be measured and paid seperately. Please Enable Macros to View BoQ information |
| 103 | M&L for 15mm thick rendering in CM 1:4 on stone masonary with water proofing compound by weight of cement finished fair complete all as specified and directed including taking downNote : Water proofing compound will be measured and paid seperately. Please Enable Macros to View BoQ information |