| 1 | Excavation in post holes (or similar holes) each n. exc. 0.5 cu m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in Hard/ dense soil complete all as specified and directed. |
| 2 | M&L for PCC 1:4:8, type D2 (using 40mm graded granite stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed. |
| 3 | M&L for providing, PCC 1:2:4 Type B-2 (using 40mm graded stone aggregate) as in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases) complete all as specified and directed. |
| 4 | M&L for MS Plate girder or single stanchions, built up of one beam or channel section with flange plates, caps, bases. splices, angle brackets, cleats and other connections made out of Fe 410-W (Gde E-250 quality A) complete all as specified and directed. |
| 5 | M&L for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc made out of Fe 410-W (Gde E-250 quality A) complete all as specified and directed. |
| 6 | M&L for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 7 | M&L for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof ridge covering / cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 8 | M&L for Preparation of new steel surfaces of any description and applying two coats of synthetic enamel paint over a coat of red oxide primer, over 10cm in width or girth,not otherwise described complete all as specified and directed. |
| 9 | M&L for Providing, supplying and installation of 8 Layer acrylic synthetic flooring for basket ball court (3 to 4mm thick) over Plain cement concrete with following stages:-(i) PATCH:- 100% Acrylic based emulsion to repair cracks of concrete and asphalt pavement should be carried out after 30 days from the date of placement of concrete. Priming the surface with 100% Acrylic Unic Floor based emulsion to improve bond of acrylic court system to the concrete or asphalt surface with RESURFACER in 2 layers of Acrylic Resurfacer 367-30 for filling and smoothing asphalt or concrete surfaces in preparation for Acrylic ITF Approved tennis court system and fills the surface chips, voids and conceals repairs while providing a smooth surface for colour coating. (ii) CUSHION COAT:- 02 layer of Acrylic Floor cushion for asphalt or concrete surfaces in preparation for Acrylic ITF approved system.(iii) ULTRA CUSHION COAT:- 02 Layers of Acrylic Floor cushion for asphalt or concrete surfaces in preparation for Acrylic ITF approved system. (iv) PRECOAT:- 2 layers of Acrylic based textured tennis topcoat. Ideal for color coating tennis and basketball courts and other sport pavement surfaces complete all as specified and directed. Note:- 1. Over 30 days old from the date of placement of concrete alongwith repairing of cracks of concrete and asphalt surfaces the Acrylic Synthetic Flooring work of Basketball / Badminton / Volleyball is carried out.2. PCC concrete shall be measured and paid separately including labour under relevant item. |
| 10 | Demolition of brickwork or stone masonry including all quoins, arches, pillars, etc., built in cement mortar including disposal of debris off the premises complete all as specified and directed. |
| 11 | M&L for Pre-cast cement concrete Type C1, 1:3:6 (20mm graded aggregates) block masonry with solid blocks, exc. 10 cm in width and setting in mortar 1:6, complete all as specified and directed. |
| 12 | M&L for 10mm thick rendering in cement mortar 1:6, on other than fair faces of brick or concrete surfaces, in any height, finished even and smooth without using extra cement complete all as specified and directed. |
| 13 | Demolition of cement concrete in ground floors and paving n.exc. 15 cm thickness (below or above ground level) and disposal of debris off the premises complete all as specified and directed. |
| 14 | M&L for 100 mm thick PCC 1:2:4, Type B1(using 20mm graded stone aggregate) as in concrete surface finished even and smooth without using extra cement as in hard standing complete all as specified and directed. |
| 15 | M& L for applying two coats of 100% Premium acrylic emulsion paint over new surfaces having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and as directed. |
| 16 | M&L for point wiring One light/Fan point controlled by one one way switch complete with PVC insulated and unsheathed flame retardant ( FRLS ) cable of 1.5 sqmm (nominal area) with stranded copper conductor single core 1100 volts grade in and including PVC casing caping, with mild steel terminal boxes (not less than 1.6 mm thick ) including earth dolly with 3mm thick plastic laminated sheet top cover of approved make and colour including 1.5 sqmm green stranded copper conductor as earth continuty with lugs complete all as specified and as directed. |
| 17 | As per item No.16 above but cable of size 2.5 sqmm |
| 18 | S&F switch socket combination multipurpose flush type 2 in 1 type (3 and 3 pin ) 6/16 Amps, 230V, AC complete all as specified and directed. |
| 19 | All as per item No. 18 above but 3 pin 6 A complete all as specified and directed. |
| 20 | S&F switch piano, flush type single pole one way 5/6 amps complete all as specified and directed. |
| 21 | S&F ceiling rose surface bakelite 65x50mm two to three terminal complete all as specified and directed. |
| 22 | S&F LED light fitting 1X20 watts, 220 V AC decorative box type with driver, holder including LED tubelight connecting upto three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed . |
| 23 | S&F sheet metal enclosure for DB's double door, single pole and neutral, 8 way including blacking plate with 200 amp rated bus bar, 240 volts fixed sunk / flush to the wall complete all as specified and directed. |
| 24 | S&F 415V 10KA 'C' curve Miniature Circuit Breaker (MCB) of TPN and current carrying capacity 16 to 32 Amp in the DB complete with connection testing and commissioning complete all as specified and directed. |
| 25 | S&F amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of single pole 6 to 32 Amp current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 26 | S&F LED flood light 170 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. |
| 27 | M&L for earthing complete with Galvanised steel earth plate eletrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below GL) with top edge of earth plate not less than 1.5 Mtr below normal ground level, earth plate surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filled in alternate layers and electrode connections by using Galvanised earth wire 4.00mm dia connected by means of bolts, nuts, check nuts and washer of galvanised iron or steel up to 7.5 mtr length, provision of 15 mm dia GI pipe medium grade for protection of GI earth wire and 20mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) , type C1 chamber, MS funnel, wire mesh, 50 mm thick RCC 1:2:4, type B1 earth pit cover with 6 Nos, 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance n. exc. 50 mtr, provision of charcoal and salt complete all as shown in electrical plate No. 3 of schedule Part-I, complete all as specefied and as directed. Please Enable Macros to View BoQ information |
| 28 | M&L for earthing complete with Galvanised steel earth plate eletrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below GL) with top edge of earth plate not less than 1.5 Mtr below normal ground level, earth plate surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filled in alternate layers and electrode connections by using Galvanised earth wire 4.00mm dia connected by means of bolts, nuts, check nuts and washer of galvanised iron or steel up to 7.5 mtr length, provision of 15 mm dia GI pipe medium grade for protection of GI earth wire and 20mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) , type C1 chamber, MS funnel, wire mesh, 50 mm thick RCC 1:2:4, type B1 earth pit cover with 6 Nos, 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance n. exc. 50 mtr, provision of charcoal and salt complete all as shown in electrical plate No. 3 of schedule Part-I, complete all as specefied and as directed. Please Enable Macros to View BoQ information |