| 1 | Dismantling plain or corrugated sheeting, any gauge, thickness complete all as specified and as directed. |
| 2 | Demolition cement concrete (un reinforement) Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 3 | Demolition of brickwork or stone/boulder masonary built in cement mortar including all quoins, arches, pillars, precast PCC bond stones including separating serviceable stones/boulders & setting aside for reuse in the work and removal of unserviceable materials from site complete all as specified and as directed. |
| 4 | S&F 0.50mm thick pre-painted galvalume aluminium zinc coating GI based corrugated steel sheets of any colour having tensile strength of 550 Mpa as in roof covering fixed with self tapping screws as in roof complete all as specified and as directed. |
| 5 | S&F 0.50mm thick pre-painted galvalume aluminium zinc coating GI based plain steel sheets of any colour having tensile strength of 550 Mpa as in as ridge,eaves,facia,valley ,gutter fixed with self tapping screws as in roof complete all as specified and as directed. |
| 6 | M&L for precast Solid block massonary (1:3:6) type C1 (using 20 mm graded crushed stone aggregate) exc 10 CM width and setting in CM morter (1:6) complete all as specified and as directed. |
| 7 | Taking down Cement plaster of any discription on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and as directed. |
| 8 | M&L 15 mm thick rendering plaster on fair faces of conc faces/ brick faces smooth without extra cement in CM (1:4) complete all as specified and as directed. |
| 9 | M&L for rendering 20 mm thick in CM (1:6) in two layers of 10mm each (outer layer CM should be added with WPC) on other than fair faces of brick or concrete surfaces, finished even & fair without using extra cement complete all as specified and as directed. Note :- WPC shall be measured and paid seperately as supply only. |
| 10 | Supply only liquid integral water proofing compound complete all as specified and as directed. |
| 11 | M&L for 25 mm thick cement concrete (1:2:4), type B-0 (using 12.50 mm graded crushed stone aggr) as in Damp proof course to horizontal or vertical surfaces including necessary formwork etc complete all as specified and as directed. |
| 12 | M&L for preparation of new plaster surfaces of wall and aplying two coats of acrylic oil emulsion distemper over a coat of chalk white primer complete all as specified and as directed. |
| 13 | M&L for Preparation of newly plastered surfaces of walls and applying two coats of cement paint over a coat of Priming plastered and other surfaces with alkali resistant primingr on new surfaces of walls complete all as specified and as directed. |
| 14 | M&L for 40 mm thick PCC (1:2:4) type B1 (using 20mm graded crushed stone aggregate) as in floor finishing cement concrete surface even and smooth (Without using extra cement) and complete complete all as specified and as directed. |
| 15 | M&L for 75 mm thick PCC (1:3:6) type C-2 (using 20mm graded crushed stone aggregate) as in floor complete all as specified and as directed. |
| 16 | Dismantling structural steel work including doors, gates but excluding framed truss etc complete all as specified and as directed. |
| 17 | M&L for mild steel rolled sections conforming to Fe - 290 (Gde E-165) as in main and cross beams, hip and jack rafters; purlins where connected to common rafter and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates including truss complete all as specified and as directed. |
| 18 | M&L for preparation of new steel surface of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. |
| 19 | S&F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and as directed. |
| 20 | S&F 4mm thick sheet glass, ordinary quality and glazing with oil putty in square n.exc 0.5 sqm in each panel complete all as specified and as directed. |
| 21 | Dismantling of wall and ceiling board (fibre pulp, insulation etc.,) /AC sheets and plywood any thickness and cover fillets and removal of dismantled materials/rubbish from site complete all as directed. |
| 22 | S&F 4mm thick Non asbestos fibre cement building boards (E-board) of approved texture, for insulation and acoustic purpose of size 595 x 595 mm size fixed with staples on snap grid as in ceiling etc complete all as specified and as directed |
| 23 | S&F for Anodised aliminium snap grid frame work for false ceiling confirming IS:733, 737 & IS:1285 ; grid size 605x605mm and hangers 4 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and as directed. |
| 24 | S&F Mild steel sheet (Thickness 1 mm) eaves gutters, galvanised class 3, half round with rounded edges and dia 150 mm complete all as specified and as directed. |
| 25 | Surface Preparation and Removal of loose Concrete : Removing & Hacking of existing concrete carefully by low imapct high frequency hammer OR by manual chipping without damaging the existing concrete or control sand blasting including cleaning the surface by Air Jet etc. complete all as specified and as directed. |
| 26 | Bonding Agent : Supply and applying a bond of fosroc Nitobond SBR Latex, Or Equivalent SBR Latex based bonding agent admix with cement as per manufacturer recommended ratio complete all as specified and as directed. |
| 27 | Patch Repair Work : Guniting concrete surface with single component fibre reinforced shrinkage compensated, polymer modified structural grade repair mortar like fosroc renderoc SP 40 or equivalent at a thickness of 40mm . The repair mortar should have a compressive strength 45 N/mm^2, flexture strength 7 N/mm^2 and tensile strength 2.5 N/mm^2 at 28 days complete all as specified and as directed. |
| 28 | Surface excavation for loose/soft soil n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out complete all as specified and as directed. |
| 29 | M&L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface of broken stone and boulder complete all as specified and as directed. |
| 30 | M&L for 75mm thick PCC (1:3:6), type C-2 (using 40 mm graded crushed stone aggregate ) as in plinth protection; path / hardstanding etc laid in bays / panels not exc. 2.00 Sqm each including construction joints at suitable interval and each corner and filled with bituminous mastic filling (1 part bitumen & 3 part sand) and finished the surface even and fairs complete all as specified and as directed. |
| 31 | M&L for Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses,etc.; vertical or to batter for fair finish surface of concrete and complete all as specified and as directed |
| 32 | M&L for PCC (1:3:6) type C-2 (using 40mm graded crushed stone agg) as in surface channel / drains complete all as specified and as directed. |
| 33 | Extra for forming fair finished drain or channel 30 cm inner girth cement concrete using extra cement including forms moulds mitred and stopped ends etc complete all as specified and as directed. |
| 34 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, etc complete all as specified and as directed. |
| 35 | M&L for PCC (1:3:6), type C2 (40 mm graded crushed stone aggregate) as in foundation and mass concrete complete all as specified and as directed. |
| 36 | S&F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 etc complete all as specified and as directed. |
| 37 | S&F in 150mm bore, PVC (SWR) pipes, single socketed in any length with rubber ring joints, laid in trenches or under floors , fixed on walls with necessary clips complete all as specified and as directed. |
| 38 | Supply and fix 110 mm bore PVC (SWR) bend of any radius for PVC (SWR) pipes, fixed to walls or fixed to steel gutter complete all as specified and as directed. |
| 39 | M&L for 100 mm thick (1:4:8), type D-1 (using 40mm graded crushed stone aggregate) as in sub base finished the surfaces fair and even complete all as specified and as directed. |
| 40 | Removing excavated soil to a dist n.exc.50m complete all as specified and as directed. |
| 41 | Excavation in over areas n.exc 1.5m deep not exc 3.0 m deep and getting out in soft/loose soil and complete all as specified and as directed. |
| 42 | M&L PCC (1:4:8), type C2 (using 40 mm graded crushed stone aggregate) on in foundation, filling and mass concrete complete all as specified and as directed. |
| 43 | M&L for walling of RR stone masonary uncoursed ,well bonded bedded and solidly hearted built in CM (1:6) incl brought upto course at interval of every 60 cm complete all as specified and as directed. |
| 44 | M&L Providing and laying 60mm thick factorymade chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; etc complete all as specified and as directed. |
| 45 | Supply and fix brass tee of outer dia 16mm dia complete all as specified and as directed. |
| 46 | Supply and laying of CPVC pipes SDR11 & Plain CPVC SDR 11 fitting on wall /ceiling or laying in floors etc of outer dia 16 mm dia complete all as specified and as directed. |
| 47 | Material & Labour for cutting existing steel tubing for alteration (Each cut measured) including Screwing existing steel tubing for alterations or additions (or lengthening screw on pipe to ffrom connector) done in position without taking down complete all as specified and as directed. |
| 48 | M&L for 15 mm dia steel tubing medium grade galvanised with all fitting fixed complete to wall and ceiling or floor complete all as specified and as directed. |
| 49 | Supply and fix stop valves, cast copper alloy , screwed down , high pressure , with crutch or butterfly handle , screwed both ends for iron or for unions and fixed to size 15mm complete all as specified and as directed. |
| 50 | Supply and fix Bib taps , cast copper alloy fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed of size 15 mm complete all as specified and as directed. |
| 51 | Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 star rated complete with all accessories such as saftey valve, thermostate, NRV, connection piece complete all as specified and as directed. |
| 52 | Taking down carefully copper/aluminium point wiring (light, socket or power) complete (fittings such as switches, ceiling roses, pendants, regulatos, sockets etc to be measured separately), and making good disturbed surfaces of walls, floors etc to match with existing surfaces complete all as specified and as directed. |
| 53 | Taking down unserviceable submain wiring of any size two single core including earth wire and pvc conduit /casing capping and removing materials on site and making good the surface of walls etc complete all as specified and as directed. |
| 54 | Taking down unserviceable distribution board of any capacity including wooden board and making good the disturbed surfaces of wall, etc including two coats of white /colour washing /distempering etc to match the existing complete all as specified and as directed. |
| 55 | M&L point wiring complete with 1.5 Sqm sincle core PVC insulated unsheathed FRLS cable 1100 volts grade (ISI marked), one Light/fan point controlled by one, one way switch with multi stranded copper conductor drawn through and including non-metallic rigid PVC medium grade conduit and conduit accessories (ISI) marked concealed in wall/fixed to roof, ceiling etc and incl provn of 1.5 sqmm PVC insulated multistranded unsheathed copper conductor cable FRLS (ISI marked) as earth continuity conductor, fabricated sunken terminal box made out of 1.60 mm thick sheet steel duly painted concealed in walls, with 3mm thick bakelite/PVC sheet ISI marked top cover with brass/chromium plated screws and cup washers for housing switches, socket outlets, fan regulators etc, complete all as specified and as directed. |
| 56 | All as per srl item No. 57.00 here-in-above but one 3 pin 5 amps switch socket outlet point on independent board complete all as specified and as directed. |
| 57 | All as per srl item No. 57.00 here-in-above but one 3 pin socket outlet 5 amps on the same board with other switches complete all as specified and as directed. |
| 58 | All as per srl item No. 57.00 here-in-above but but wiring with 2.5 sq.mm multistranded cable and earth wire with copper conductor complete all as specified and as directed. |
| 59 | All as per srl item No. 57.00 here-in-above but wiring with 4 sq.mm multistranded cable and earth wire with copper conductor of size 4 sq.mm complete all as specified and as directed. |
| 60 | Supply and fix switch piano flush type single pole , one way 6 Amp 230 Volts,50Hz, ISI marked complete all as specified and as directed. |
| 61 | Supply and fix Socket outlet 2 in 1, 3 pin ,6A 230 Volts,50Hz, ISI marked complete all as specified and as directed. |
| 62 | Supply and fix switch piano flush type single pole , one way 16 Amp 230 Volts,50Hz, ISI marked complete all as specified and as directed. |
| 63 | Supply and fix Socket, outlet 2 in 1 , 3 pin , 6 Amp and 16 amp flush type 230 V 50Hz,ISI marked complete all as specified and as directed. |
| 64 | Supply & fixing LED lights fitting 1x18 watt 220 V, AC decorative box type with driver , holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 65 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed. |
| 66 | Supply & fixing LED lights fitting 1x9 /1x10 W 220 V, AC bulk head luminaries including , holder including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. |
| 67 | S&F ceiling rose, 3 phase ,PVC polycarbonate ,insulated body (ISI Marked) complete all as specified and as directed. |
| 68 | S&F single pole & neutral enclosure with a two pin & earth plug & socket complete with one single pole MCB C curve of 20 A rating complete all as specified and as directed. |
| 69 | M&L for concealed sub-main wiring along with earth wire of size e 2x06 sqmm with 1x6 sqmm earth wire ,ISI marked FRLS ,PVC insulated ,multi stranded , copper conductor ,single core cable drawn through and incl PVC rigid conduit (medium grade) size not less than 25 mm with all fittings and accessories ISI marked including cutting chases for conduit & sinking for sunken boxes & making good to walls, floors etc complete all as specified and as directed. |
| 70 | S&F for MCB DB TPN 4 ways Double Door 240 Volt with 200 Amp rated bus bar ,IP-42,IK-09, metal door, earth bar, neutral links complete incl blanking plates as required & fixed flush to wall / other surface complete all as specified and as directed. |
| 71 | S&F for MCB DB SPN 8 ways Double Door 240 Volt with 200 Amp rated bus bar ,IP-42,IK-09, metal door, earth bar, neutral links complete incl blanking plates as required & fixed flush to wall / other surface complete all as specified and as directed. |
| 72 | S&F for MCB DB SPN 12 ways Double Door 240 Volt with 200 Amp rated bus bar ,IP-42,IK-09, metal door, earth bar, neutral links complete incl blanking plates as required & fixed flush to wall / other surface complete all as specified and as directed. |
| 73 | S&F MCB TPN 40 to 100 Amps , 415 Volts , 10 KA rupturing capacity , C curve complete all as specified and as directed. |
| 74 | S&F MCB single pole & neutral SPN 32 to 63 Amps , 240 Volts , 10 KA rupturing capacity , C curve complete all as specified and as directed. |
| 75 | S&F MCB single pole 6 to 32 Amps , 240 Volts , 10 KA rupturing capacity , C curve complete all as specified and as directed. |
| 76 | Supply and fixing LED building light fitting 35 watt 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP65 /66 protection and impact resistance of IK07 complete GI bracket 1.5m long made out of GI dia suitable for fixing street lights bend to suitable radius incl 2 sets of clamps nuts bolts washers incl painting with aluminium paint etc complete all as specified and as directed. |
| 77 | Taking up existing defective cable of size 2/3/3.5/4 core 10 to 70 sqmm from the trenches ducts /along walls /poles/ under road inside sub station all as specified and as directed. |
| 78 | Supply ,laying ,jointing and testing in trenches or passing through pipe, 1100 Volts grade XLPE insulated, armoured heavy duty electric cable with aluminium conductor of cross sectional area 16 Sqmm 4 core with necessary fixing arrangements such as lugs, glands and terminal etc complete all as specified and as directed. |
| 79 | Supply and laying DWC pipe SN-4 with coupler 40mm OD, ISI marked along with all accessories like socket, bend, couplers etc. Conforming to IS 14930, PartII complete with fitting and cutting , jointing etc. Laid in trenches/fixed to pole /laying under road crossing /fixed on pavement wall with clamps complete all as specified and as directed. |
| 80 | Supply, jointing, testing and laying in trenches/floor/wall etc pipes galvanised iron \\"Medium grade\\" ISI marked with all running fittings of size 50 mm bore complete all as specified and as directed. |
| 81 | M&L for Excavation in trenches n. Exc 1.5 mtr wide and n.exc 1.5 mtr depth for laying of cable / foundation of pole and getting out in loose /hard /rocky soil complete all as specified and as directed. |
| 82 | M&L for Returning filling in loose /hard /rocky soil including spreading ,levelling ,watering and well ramming in layers not exceeding 25cm complete all as specified and as directed. |
| 83 | M&L for Removal of surplus excavated (soil) to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.50 m above the starting point complete all as specified and as directed. |
| 84 | M&L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5mtrs below normal ground level connected with galvanised iron/steel earth wire of 4 mm dia by means of bolts, nuts, check nuts and washers made out of galvanised iron or steel all as shown in electrical plate No 3 of SSR Part-I and earth wire protected by galvanized pipe light grade 15mm bore and connected to DBs including necessary earthwork and excavation in any type of soil, GI light grade 20mm bore watering pipe with funnel and wire mesh, PCC (1:2:4) type B1 chamber with 40mm thick RCC (1:2:4) type B1 design mix cover slab with 6mm dia MS bars at 100mm c/c both ways with MS Hook 6mm dia MS bars etc complete all as specified and as directed. Please Enable Macros to View BoQ information |